Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout2024-05-07 - Agenda Packet
MAY 7, 2024- 6:00 P.M.
DESIGN REVIEW COMMITTEE
MEETING AGENDA
RAINS ROOM
CITY HALL
10500 Civic Center Drive
Rancho Cucamonga, CA 91730
A. Call to Order
Roll Call: Vice Chairman Al Boling
Commissioner James Daniels
B. Public Communications
This is the time and place for the general public to address the Committee on any item listed or not
listed on the agenda. The Committee may not discuss any issue not included on the agenda but set
the matter for a subsequent meeting.
C. Consent Calendar
C1. Consideration to adopt Meeting Minutes of April 16, 2024.
C2. DESIGN REVIEW – ELECTRIC PICKLE - A request to construct a 12,074 square-foot
building for a restaurant/bar with outdoor patio dining; 9 pickle-ball courts; and a 1,771
square-foot building with a coffee bar, restrooms, and storage within the Urban
Neighborhood General Plan designation and The Resort Specific Plan, located at the
northwest corner of 4th Street and Resort Parkway - APN: 0210-102-07 (Design Review
DRC2023-00248).
D. Project Review Items
D1. DESIGN REVIEW – BISHOP VENTURES – A request to construct a multi-family residential
development comprising 145 residential units on 2.72 acres of land at the northeast corner of
Foothill Boulevard and Lion Street in the Corridor 1 (CO1) Zone. APN: 0208-632-47 (DRC2022-
00354).
D2. DESIGN REVIEW – LONE OAK-RANCHO, LLC– A request to redevelop and expand an
existing beverage distribution facility over two phases to include production, bottling and
distribution operations on approximately 30.11 acres of land generally bounded by Haven
Avenue to the west, 7th Street to the north, Utica Avenue to the east, and 6th Street to the south
in the Mixed Employment 2 (ME2) Zone. APN: 0209-411-002, -003, 004, -023, -24, -32, -34,
-35 (DRC2023-00067).
Design Review Committee Meeting Agenda – May 7, 2024
Page 2 of 2
If you need special assistance or accommodations to participate in this meeting, please
contact the Planning Department at (909) 477-2750. Notification of 48 hours prior to the
meeting will enable the City to make reasonable arrangements to ensure accessibility.
Listening devices are available for the hearing impaired.
E. Adjournment
The Design Review Committee has adopted Administrative Regulations that set an 11:00 p.m. adjournment
time. If items go beyond that time, they shall be heard only with the consent of the Committee.
I, Elizabeth Thornhill, Executive Assistant of the City of Rancho Cucamonga, or my designee,
hereby certify that a true, accurate copy of the foregoing agenda was posted seventy-two (72)
hours prior to the meeting per Government Code 54954.2 at 10500 Civic Center Drive, Rancho
Cucamonga, California and on the City’s website.
Design Review Committee
Meeting Agenda
April 16, 2024
DRAFT MINUTES
Rancho Cucamonga, CA 91730
6:00 p.m.
A. Call to Order
The meeting of the Design Review Committee held on April 16, 2024. The meeting was called to order by
Sean McPherson, Staff Coordinator, at 6:00 p.m.
Design Review Committee members present: Vice Chairman Al Boling and Commissioner James Daniels.
Staff Present: Tabe van der Zwaag, Assistant Planner; Adam Pisarkiewicz, Senior Planner.
B. Public Communications
Staff Coordinator opened the public communication and after noting there were no public comments,
closed public communications.
C. Consent Calendar
C1. Consideration to adopt Regular Meeting Minutes of March 19, 2024.
Motion carried 2-0 vote to adopt the minutes as presented.
D. Project Review Items
D1. DESIGN REVIEW – WESTERN SPIRE – A request for a site plan and design review of a mixed-use
development consisting of 176 residential units (including 2 live-work units), 7,870 square feet of commercial
lease area, and 1,400 square feet of live-work commercial lease area on 1.8 acres of land at the northeast
corner of Red Oak and Spruce Avenues in the Center 2 (CE2) Zone. APN: 208-353-18 (DRC2023-00154).
Staff presented the item to the Design Review Committee. Following the staff’s presentation, members of
the applicant team (Western Spire), including their architect provided additional background and detail on
the project. Following the presentation discussion ensued over various aspects of the project.
The Committee was complimentary of the project design and amenities and was accepting of the proposed
reduction in the square footage of the non-residential floor area. They stated there were adequate
commercial and office uses adjacent to the building and that creating housing was a priority.
The Committee raised mild concerns about the requested reduction in on-site parking. The applicant stated
that they have a parking management plan to ensure adequate on-site parking. The Committee asked
questions about the location of parking spaces for guests, customers, and delivery trucks and whether the
roundabout would require modification of the existing drive approaches for the surrounding land uses. The
applicant outlined the parking and staff stated that the drive approaches are not expected to be impacted by
the roundabout. The Committee recommended that the project be forwarded to the Planning Commission
for their review.
The Committee took the following action:
Recommend approval to PC. 2-0 Vote.
D2. DESIGN REVIEW – FORE PROPERTY (FOOTHILL AND GROVE MIXED USE) – A request to
construct a mixed-use development comprising 308 residential units and 14,704 square feet of commercial
lease area on 9.15 acres of land at the northeast corner of Foothill Boulevard and Grove Avenue in the
Center 1 (CE1) Zone. APN: 0207-011-35, 36, 41, 43, 44, and 45 (DRC2022-00379).
Staff presented the item to the Design Review Committee. Following the staff’s presentation, members of
the applicant team (Western Spire), including their architect provided additional background and detail on
the project. Following the presentation discussion ensued over various aspects of the project.
The Committee was complimentary of the project design and amenities and was accepting of the proposed
reduction in the square footage of the non-residential floor area. They stated there were adequate
commercial and office uses adjacent to the building and that creating housing was a priority.
The Committee raised mild concerns about the requested reduction in on-site parking. The applicant stated
that they have a parking management plan to ensure adequate on-site parking. The Committee asked
questions about the location of parking spaces for guests, customers, and delivery trucks and whether the
roundabout would require modification of the existing drive approaches for the surrounding land uses. The
applicant outlined the parking and staff stated that the drive approaches are not expected to be impacted by
the roundabout. The Committee recommended that the project be forwarded to the Planning Commission
for their review.
The Committee took the following action:
Recommend approval to PC. 2-0 Vote.
E. Adjournment
Meeting was adjourned at 8:00 p.m.
Respectfully submitted,
Elizabeth Thornhill, Executive Assistant
DESIGN REVIEW COMMENTS
May 7, 2024
6:00 p.m.
Bond Mendez, Associate Planner
DESIGN REVIEW – ELECTRIC PICKLE - A request to construct a 12,074 square-foot building
for a restaurant/bar with outdoor patio dining; 9 pickle-ball courts; and a 1,771 square-foot building
with a coffee bar, restrooms, and storage within the Urban Neighborhood General Plan
designation and The Resort Specific Plan, located at the northwest corner of 4th Street and Resort
Parkway - APN: 0210-102-07 (Design Review DRC2023-00248).
Revised Design: Since the previous DRC meeting held on March 19, 2024, the applicant has
revised the design of the primary structure. The revised design is a result of a model that better
suits the engineering of the building.
The change to the building is the second floor has now been relocated to the ground floor to
create a single-story building. The overall floor area of the building is reduced but the revised floor
plan does not result in new uses within the building or on the site. The architecture is consistent
with the original design and elements will be continued with the re-design..
The impact to the site is the loss of one pickleball court but the remaining site layout remains the
same for the outdoor space, parking, and landscaping. The structure is consistent with the Resort
South Specific Plan development requirements. The secondary building on the corner of Resort
Parkway and 4th Street also remains in place.
Figure 1: View of Building 1 east elevation from Resort Parkway.
DRC COMMENTS
DESIGN REVIEW DRC2023-00248 – ELECTRIC PICKLE
May 7, 2024
Page 2OMMENTS
Figure 2: Revised Site Plan
Staff Recommendation: Staff requests the Design Review Committee to review the project, and
recommends the selected action below to the Planning Commission:
☒Recommend Approval of the design of the project as proposed by the applicant.
☐Recommend Approval with Modifications to the design of the project by incorporating
revisions requested by the Committee. Follow-up review by the Committee is not required. The
revisions shall be verified by staff prior to review and action by the Planning Director / Planning
Commission.
☐Recommend Conditional Approval of the design of the project by incorporating revisions
requested by the Committee. Follow-up review by the Committee is not required. The revisions
DRC COMMENTS
DESIGN REVIEW DRC2023-00248 – ELECTRIC PICKLE
May 7, 2024
Page 3OMMENTS
shall be Conditions of Approval and verified by staff during plan check after review and action by
the Planning Director / Planning Commission.
☐Recommend Denial of the design of the project as proposed by the applicant.
Design Review Committee Action:
Staff Planner: Bond Mendez, Associate Planner
Members Present:
Staff Coordinator: Sean McPherson, Principal Planner
Exhibit A – DRC Comments March 19, 2024
Exhibit B – Project Plans
DESIGN REVIEW COMMENTS
March 19, 2024
6:00 p.m.
Bond Mendez, Associate Planner
DESIGN REVIEW – ELECTRIC PICKLE - A request to construct a 14,678 square-foot building
for a restaurant/bar with outdoor patio dining; 10 pickle-ball courts; and a 1,771 square-foot
building with a coffee bar, restrooms, and storage within the Urban Neighborhood General Plan
designation and The Resort Specific Plan, located at the northwest corner of 4th Street and Resort
Parkway - APN: 0210-102-07 (Design Review DRC2023-00248).
Site Characteristics and Background: The 2.88-acre vacant lot is located at the southernmost
portion of the Resort Specific Plan Planning Area 1A (PA1A). The location of the project site is
within area S-19, which is designated as the Mixed-Use (MU) Placetype. The project site has
dimensions of approximately 331 feet (east to west) and 340 feet (north to south). The remainder
of the Resort is developed with condominiums along the east side of The Resort Parkway and is
developed with apartment buildings and amenities along the west side of The Resort Parkway.
The existing Land Use, General Plan, and Zoning Designations for the project site and adjacent
properties are as follows:
Land Use General Plan Zoning
Site Vacant Urban Neighborhood The Resort Specific Plan,
Planning Area 1A
North Multi-Family Residential Urban Neighborhood The Resort Specific Plan,
Planning Area 1A
South City of Ontario Urban Commercial Ontario Center Specific Plan
East Multi-Family Residential Urban Neighborhood The Resort Specific Plan,
Planning Area 1A
West Office/Business Park 21st Century
Employment Mixed Employment 2 (ME2)
Project Overview and Site Planning: The applicant proposes to construct two commercial
buildings totaling 16,449 square feet. Building 1 measures 14,678 square feet and is located in
the center of the site. Building 2 measures 1,771 square feet and is located at the southeast
corner of the site. The larger building is the two-story primary structure proposed to include a
restaurant, bar, and outdoor dining. It also includes a small retail “pro shop” and indoor golfing
range simulation for recreation. The smaller single-story building on the corner is a coffee bar that
will have limited operating hours and will feature a walk-up window that faces the public right-of-
way on the corner of 4th Street and Resort Parkway. The site includes 10 pickle-ball courts, 2
bocce courts, and open lawn space for general leisure. The site will be accessed via a single
driveway from Resort Parkway.
Exhibit A
DRC COMMENTS
DESIGN REVIEW DRC2023-00248 – ELECTRIC PICKLE
March 19, 2024
Page 2OMMENTS
Landscape: Landscaping is generally distributed along the project’s 4th Street frontage, along the
west property line, and distributed throughout the parking lot. There is also landscaping including
trees and a lawn area within the interior/central portion of the site. The project will be conditioned
to incorporate tiered landscaping along the street frontages in compliance with the Resort Specific
Plan.
Architecture: The proposed buildings will have an industrial architectural style including standing
seam metal paneling painted with a palette of two colors including dark bronze and slate gray.
The buildings will include Hardie siding panels in an evening blue color finish, and Indiana
limestone veneer accents at various locations. Other than the south elevations both buildings,
which include the outdoor dining on the primary building and walk-up window on the secondary
building, there is limited articulation designed throughout the wall planes in order to maximize the
efficiency of the interior space and accommodate the back-of-house uses. However, this limited
articulation does not result in an overwhelming building mass, as trellis projections aide in
breaking up the building façades. Additionally, the application of glass panels along the building’s
rear elevations, which is mostly visible from the parking lot and property to the north, adds
architectural interest to the wall planes.
DRC COMMENTS
DESIGN REVIEW DRC2023-00248 – ELECTRIC PICKLE
March 19, 2024
Page 3OMMENTS
Figure 1: View of Building 1 north elevation from interior of the site within the parking lot.
Figure 2: View of Building 2 south and east elevation from the corner of 4th Street and Resort Parkway.
Development Standards: The project complies with all pertinent standards in the Mixed-Use (MU)
Placetype of the Resort Specific Plan, as demonstrated in the following table:
DRC COMMENTS
DESIGN REVIEW DRC2023-00248 – ELECTRIC PICKLE
March 19, 2024
Page 4OMMENTS
Parking: Parking is distributed across the northern and eastern portions of the site between the
property to the north and along the frontage on Resort Parkway. Required parking for the project
was calculated with the floor areas for both buildings and then deducting areas of the buildings
as allowed within the Development Code. Based on this calculation, the project will require a total
of 120 vehicle parking stalls. The project provides 139 stalls, meeting the parking requirement.
Signage: The conceptual signage within the plans is not part of the review and will be subject to
a separate application and review with Planning and Economic Development staff.
Staff Recommendation: Staff requests the Design Review Committee to review the project, and
provide direction on the following outstanding design recommendations by Staff:
• Fences and Walls. Staff recommends replacing all proposed solid walls with tubular style
fencing, and to remove or relocate fencing from specific areas of the site.
• Shade structures. Staff recommends adding shade structures over all the outdoor
recreation courts. The applicant is proposing to install shade structures over the
recreational courtside seating areas.
• Elevations: Staff is recommending enhancing the elevations to break up massing and
potentially incorporate more fenestration, particularly along the east elevation of the
primary building which also enhances the building entry and primary façade.
With these design considerations, Staff recommends the selected action below to the Planning
Commission:
☐Recommend Approval of the design of the project as proposed by the applicant.
☒Recommend Approval with Modifications to the design of the project by incorporating
revisions requested by the Committee. Follow-up review by the Committee is not required. The
revisions shall be verified by staff prior to review and action by the Planning Director / Planning
Commission.
☐Recommend Conditional Approval of the design of the project by incorporating revisions
Development Standard Required Proposed Complies?
Building Height Max. 60’ 39’ YES
Floor Area Max 35,000 16,449 YES
Resort Parkway ROW Min. 5’ 5’ YES
4th Street ROW Min. 10’ 10’ YES
PA1A Boundary Setback from Cleveland
Avenue Min. 10’ 10’ YES
Setback from Interior Property Line 0’ 134’ YES
DRC COMMENTS
DESIGN REVIEW DRC2023-00248 – ELECTRIC PICKLE
March 19, 2024
Page 5OMMENTS
requested by the Committee. Follow-up review by the Committee is not required. The revisions
shall be Conditions of Approval and verified by staff during plan check after review and action by
the Planning Director / Planning Commission.
☐Recommend Denial of the design of the project as proposed by the applicant.
Design Review Committee Action:
Staff Planner: Bond Mendez, Associate Planner
Members Present:
Staff Coordinator: Sean McPherson, Principal Planner
Exhibit A – Project Plans
S1 @ 20'S1 @ 20'
S1 @ 20'
P1 @ 20'
S2 @ 20'S2 @ 20'S2 @ 20'S2 @ 20'S2 @ 20'S2 @ 20'S2 @ 20'
P3 @ 20'P3 @ 20'P3 @ 20'
P1 @ 20'
S1 @ 20'EV CAPABLEPARKINGEV CAPABLEPARKINGEV CAPABLEPARKINGEV CAPABLEPARKINGEV CAPABLEPARKINGEV CAPABLEPARKINGEV CAPABLEPARKINGEV CAPABLEPARKINGTRASH/
GREASE
139 TOTAL PARKING SPACES
CLEVELAND AVENUETHE RESORT PARKWAYLOT 7
116,728 SF
2.68 AC.
4TH STREET 10'-0"MAIN BUILDING
ONE STORY (12,977 GSF FOOTPRINT)
12
8
16 1812
7 12
7
1112
13 11
CABANA BUILDING
1-STORY
1,765 GSF6'-6"5'-0"
118'-8" TO F.O.C.
121'-5" TO F.O.C.
94'-8" TO P.L.
107'-7" TO P.L.
16'-3"
TO F.O.C.
1
3
4
4 4 4 4 4 4 4 4
5
6
7
8
9
10
11
10
12
12
1314
15
16
17
18
20
21
22
23
26
28
29
24
30
35
36
39
20'-0"20'-0"10'-0"10'-0"
10'-0"10'-0"331'-3.3"328'-2.2"3
0
'
-
0
.
8
"
288'-11.3"
29'-4.
2"186'-11.9"152'-5.6"133'-7"45'-4"
10'-8"
10'-5"20'-3"52'-8"
48'-5"
11'-8"
31.01
03.10 03.10
03.07
24
24
24
24
19
31.01 31.01
03.04 03.04
31.01
31.01 31.0131.0131.01
31.01
31.01
31.01
24
31.0131.01
31.01
03.04
03.04
03.04
32.09
31.01
31.01
03.04
03.04
31.01
32.10
32.10
32.10
32.10
32.10
32.10
32.10
32.10
32.10
32.10
1111
32.11
32.11
22.03
05.09
32.10
03.16
03.08
03.08
03.08
31.01 31.01 31.01
32.0832.04
32.0532.05 32.05
888
26.02 26.02 26.02
26.02 26.02
26.0326.0326.0326.03 26.03 26.0326.0326.03 26.03
26.03 26.03
05.10
05.10
03.14
03.14
03.13
03.13
03.19
05.08
05.10 05.11
08.1221.01
21.02 26.04
22.01
22.04
32.02
32.06
32.06
32.07
04.03 05.17
04.02 (E)
04.02 (E)
04.02
05.16
05.16
05.15
04.03 05.17
04.03
05.13
05.13
05.17
31.01
26.05
04.03
10.0210.0210.0210.0210.02
01.01 01.01
18'-6"42'-6"
32.03
6'-0"
NORTH G100
SITE PLAN
CONSULTANTS:
CERTIFICATION:Project No.Drawn ByChecked ByDateRevision Date
THIS DRAWING IS PART OF A SET OF WORKING DRAWINGS. THE INFORMATION CONTAINED ON THIS DRAWING MUST BE COORDINATED WITH THE BALANCE OF THE DRAWINGS, AND CANNOT BE TAKEN AS A STAND-ALONE INSTRUCTION. ALL GENERAL NOTES AND SPECIFICATIONS APPLY TO EVERY SHEET IN THIS SET.MXRJEDContact: Paul Frederick12101 S. Crenshaw Blvd. #400Hawthorne, CA 90250paul@eurekarestaurantgroup.com310-331-823211301ELECTRIC PICKLERANCHO CUCAMONGA2024/01/19PLAN CHECK #:CASE #:*For additional information and project requirements and instructions visit www.brickandwest.com/build PLAN CHECK #:__________TRACKING #:__________PROGRESS
DRAWINGS
NOT FOR
CONSTRUCTION
1 OVERALL SITE PLAN
1"=20'-0"
SITE PLAN KEYNOTES
1 SERVICE YARD ENCLOSURE (MASONRY WALLS)
2 PARKING LOT LIGHTING (SEE SHEET G800)
3 BACK YARD BOCCE COURT
4 PICKLE BALL COURT
5 COVERED CABANA
6 COVERED OUTDOOR BAR
7 RESTROOMS / STORAGE BUILDING
8 OUTDOODR SEATING AREA
9 COVERED PERGOLA/ENTRY
10 GATES
11 DECORATIVE SITE FENCE (8'-0" H.) (SEE ELEVATIONS)
12 LINE OF OPEN_AIR SHADE STRUCTURE ABOVE (SEE ELEVATIONS)
13 SYNTHETIC TURF
14 FIRE PIT SEATING AREA
15 COVERED 'FRONT PORCH'
16 TRASH ENCLOSURE (MASONRY/SOLID GATES)
17 CONCRETE APRON / PAVEMENT
18 SES / ELECTRICAL SERVICE
19 CONT. TRENCH DRAIN WITH SAND/OIL INTERCEPTOR
20 GREASE INTERCEPTOR
21 STAGE
22 OUTDOOR LOUNGE AREA
23 PROPERTY LINE
24 FLUSH PAVEMENT / PED CROSSING
26 CENTERLINE AT ROW
28 AT GRADE LANDSCAPE AREA (SEE LANDSCAPE PLANS)
29 FIRE RISER ROOM / FDC
30 TRELLIS OVERHANG (SEE ELEVATIONS)
31 EXISTING SIDEWALK, CURB, AND GUTTER TO REMAIN
35 BICYCLE PARKING
36 NEW FIRE HYDRANT
39 WATER FEATURE - SEE DETAILS
SITE PLAN SPECIFICATION NOTES
SHEET G100 REFER TO SHEET G630 FOR SITE FINISHES (XX)
01.01 Designated loading zone with signage (10.02) to keep clear during
receieving and service hours.
03.04 CO1 Concrete sidewalk (see Civil Drawings). Integral color concrete
SIKA 'Smoke' or Lanon Stone' with top casst 15 finish (See Landscape).
Trowel finish. Concrete sealer.
03.05 Align saw cut Control joints 1" deep minimum for 4" slabs and at building,
planing area, and wall corners in all concrete flatwork. Minimum joint
spacing: 8 Feet.
03.07 Concrete 'Apron' slab as shown (see Civil)
03.08 Stamped integral color concrete - 'flagstone look' GC to provide mock-up
for approval by Brick & West prior to execution.
03.09 Gray concrete slab (see Civil drawings for additional information) finish to
match concrete work at site (driveway aprons)
03.10 ADA ramp (maximum slope 1:12). See Civil for grades.
03.11 CIP concrete water feature. See details. See plumbing for water and
drainage information.
03.12 (AK) CIP concrete wall (see elevations)
03.13 (AK) CIP Feature wall (see details)
03.14 (AK) CIP stepped seating wall. See details. See electiral and lighting
plans for step light specifications. 3/A504
03.16 Raised concrete stage (see Civil). See details.
03.18 Concrete ramp 1:12 max. slope. See details
03.19 CIP concrete fireplace. See site details. See plumbing for gas
information.
04.02 CMU (Masonry) perimiter wall at multi-family parcel to the north.
04.03 CMU (Masonry) pilaster to match multi-family parcel to the north. See
8/A503
05.08 Steel 'picket' fence (see design intent drawings). 3/A503
05.09 Steel view fence (see design intent drawings). Coordinate with retaning
walls and gates. 5/A503. Painted PT-02 per specifications.
05.10 Decorative steel EXIT gate. See door schedule and notes. Painted PT-02
per specifications.
05.11 Steel trellis (see structural) painted PT-02 per speficicatons.
05.13 Decorative tubular steel perimiter fence to match mult-family parcel to
north see 1/A503
05.14 Tubular steel gate at perimeter fence see to match 05.13 (by fence mfr.)
05.15 Metal fence at building entry locations (Electric Pickle standard) see
5/A503
05.16 Metal gate at building entry locations (Electric Pickle standard see
5.1/A503
05.17 Decorative steel fence see 3/A503
08.12 Steel doors at electrical cabinet. See door schedule. PT-02 per
specifications.
10.02 NO PARKING BETWEEN 5AM-11AM' sign mounted on steel gates at
enclosure wall.
21.01 F.D.C.
21.02 Fire Riser
22.01 Continuous trench drain tied to sand-oil interceptor. GC to coordinate
final elevation with concrete pour to ensure proper sheet flow to drain.
22.02 Grease interceptor (see plumbing)
22.03 Water feature (design-build) - see Plumbing drawings.
22.04 Gas plumbing to fire feature. See plumbing drawings
26.02 Site / parking lot lighting pole. See architectural details for base
dimensions and details. 4/A502
26.03 Pickleball court lighting (pole mounted). See electrical and lighting plans
and specifications for details. Coordinate shielding to elminate light
trespass beyond edge of court.
26.04 Service Entry Section (SES) / Electrical Gear (See electrical)
26.05 (E) Electrical transformer
31.01 Art-grade planting area (turn-down edge from flatwork). See landscape
plans for planting and irrigation requirements. See electrical and lighting
plans for landscape lighting information.
31.02 Elevated/curbed planting area. See landscape drawings for planting and
irrigation specifications. See electrical and lighting plans for landscape
lighting information.
32.01 Heavy-duty parking block (tupical as shown on site plan). Centered on
parking stall.
32.02 A-Safe 'I-Flex' Bollard anchored per all manufacturer's specifications and
requiements.
32.03 Bicycle Racks (see site furnishings schedule). Install per all
manufacturer's speficiations and instructions. 6/A502
32.04 (AE) Stablizied compacted decomposed granite paving.
32.05 18" deep hedge min 42" height. See landscape drawings for planting and
irrigation specifications. See electrical and lighting plans for landscape
lighting information.
32.06 Planting and planter within CIP concrete wall. See landscape drawings
for planting and irrigation specifications. See electrical and lighting plans
for landscape lighting information.
32.07 Fire feature as specificed. Coordinate final loation and gas routing with
plumbing drawings.
32.08 (AF) Synthetic lawn as specificed. See site finish schedule. See also civil
for graing, drainage, and substrate information.
32.09 Raised planter clad in steel. See site details. See landscape drawings for
planting and irrigation specifications. See electrical and lighting plans for
landscape lighting information.
32.1 Pickleball Court. see plans and specifications from court subcontractor
32.11 Bocce Ball Court - see plans and specifications from court subcontractor.
Edge details and lighting per archietctural and electrical.
PARKING SUMMARY (17.64):
108 REQUIRED (10,799 @ 10/1000 SF)
139 VEHICLE SPACES PROVIDED
5% BICYCLE PARKING 7 REQUIRED 9 PROVIDED
5% EV CAPABLE PARKING 7 REQUIRED 7 PROVIDED
ADA SPACES REQUIRED
101-150 SPACES = 5 REQ'D
6 PROVIDED
Building 1 Restaurant/Bar
First Floor Space/Use Sq. Ft. Space/Use Sq. Ft.
Pro Shop 216 Utility Room 243.5
Bar 800 Walk-In Fridge 319
Dining 2,306 Walk-in Freezer 92.5
Patio 1,571 Keg Cooler 188
Elevator 76 Liquor Storage 74.5
Entry/Host 298 Dry Storage 204
Server 134.5 Prep 357
Stairway 1 217 Cook 410
Stairway 2 225 Expo 337
Bathroom 507 Dish 349
Riser Room 66.5 Pizza 243
SES Room 122 Beverages 118
AVIT-A Room 110
Building 1 Restaurant/Bar
Second
Floor
Space/Use Sq. Ft.
Bar 200
Golf 788
Dining 1,863
Patio 1,024
Bathroom 251
Admin Offices 95
Host/Entry 185
Stairway 1 217
Stairway 2 225
Storage Closets 169
Bev Serv 76
Building 2 Cabana
Space/Use Sq. Ft.
Bar 400
Coffee 319
Service/Beverag
es
191.5
Dry Storage 298
Water
Treatment
64
Walk In 106
Restrooms 315
Riser Room 77
TOTAL GROSS 14,742
DEDUCTIONS (1)3,943
PARKING TOTAL AREA 10,799
Exhibit B
P1 @ 20'
20'
NORTH
CONSULTANTS:
CERTIFICATION:Project No.Drawn ByChecked ByDateRevision Date
THIS DRAWING IS PART OF A SET OF WORKING DRAWINGS. THE INFORMATION CONTAINED ON THIS DRAWING MUST BE COORDINATED WITH THE BALANCE OF THE DRAWINGS, AND CANNOT BE TAKEN AS A STAND-ALONE INSTRUCTION. ALL GENERAL NOTES AND SPECIFICATIONS APPLY TO EVERY SHEET IN THIS SET.MXRJEDContact: Paul Frederick12101 S. Crenshaw Blvd. #400Hawthorne, CA 90250paul@eurekarestaurantgroup.com310-331-823211301ELECTRIC PICKLERANCHO CUCAMONGA2024/04/24PLAN CHECK #:CASE #:*For additional information and project requirements and instructions visit www.brickandwest.com/build PLAN CHECK #:__________TRACKING #:__________PROGRESS
DRAWINGS
NOT FOR
CONSTRUCTION
CONSULTANTS:
CERTIFICATION:Project No.Drawn ByChecked ByDateRevision Date
THIS DRAWING IS PART OF A SET OF WORKING DRAWINGS. THE INFORMATION CONTAINED ON THIS DRAWING MUST BE COORDINATED WITH THE BALANCE OF THE DRAWINGS, AND CANNOT BE TAKEN AS A STAND-ALONE INSTRUCTION. ALL GENERAL NOTES AND SPECIFICATIONS APPLY TO EVERY SHEET IN THIS SET.MXRJEDContact: Paul Frederick12101 S. Crenshaw Blvd. #400Hawthorne, CA 90250paul@eurekarestaurantgroup.com310-331-823211301ELECTRIC PICKLERANCHO CUCAMONGA2024/04/24PLAN CHECK #:CASE #:*For additional information and project requirements and instructions visit www.brickandwest.com/build PLAN CHECK #:__________TRACKING #:__________PROGRESS
DRAWINGS
NOT FOR
CONSTRUCTION
1 FIRST FLOOR PLAN - MAIN BUILDING
1/8" = 1'-0"
A100
FIRST FLOOR OVERALL
MAIN BUILDING
3A 19 1527 73A41
29'-10"17'-0"25'-0"14'-0"102'-9"
3 1924
13'-0"13'-0"2 2
6'-0"15 2 2A33322424
7 3
14'-0"29'-10"17'-0"25'-0"3A
74'-6"
2A
102'-9"20'-0"2 41
3885
39 243
A200
EXTERIOR ELEVATIONS
CONSULTANTS:
CERTIFICATION:Project No.Drawn ByChecked ByDateRevision Date
THIS DRAWING IS PART OF A SET OF WORKING DRAWINGS. THE INFORMATION CONTAINED ON THIS DRAWING MUST BE COORDINATED WITH THE BALANCE OF THE DRAWINGS, AND CANNOT BE TAKEN AS A STAND-ALONE INSTRUCTION. ALL GENERAL NOTES AND SPECIFICATIONS APPLY TO EVERY SHEET IN THIS SET.MXRJEDContact: Paul Frederick12101 S. Crenshaw Blvd. #400Hawthorne, CA 90250paul@eurekarestaurantgroup.com310-331-823211301ELECTRIC PICKLERANCHO CUCAMONGA2024/04/02PLAN CHECK #:CASE #:*For additional information and project requirements and instructions visit www.brickandwest.com/build PLAN CHECK #:__________TRACKING #:__________PROGRESS
DRAWINGS
NOT FOR
CONSTRUCTION
1 MAIN BUILDING ELEVATION - EAST
3/16" = 1'-0"
2 MAIN BUILDING ELEVATION - WEST
3/16" = 1'-0"
MATERIAL AND FINISH SCHEDULE
SEE SHEET A630 FOR ADDITIONAL DETAIL ON MATERIALS
2 INDIANA LIMESTONE VENEER (C) SQUARE-CUT
INDIANA LIMESTONE VENEER BUILDING ACCENT
MATERIAL. SITE WALLS
2A CIP BOARD-FORMED CONCRETE (AK)
3 STANDING SEAM METAL (DARK GRAY) (A) WESTERN
WAVE METAL RIGID WALL PANEL 'DARK BRONZE' 24
GA. MANUFACTURER: WESTERN STATES METAL
ROOFING
3A STANDING SEAM METAL (LIGHT GRAY) (B) WESTERN
WAVE METAL RIGID WALL PANEL 'SLATE GRAY' 24 GA.
MANUFACTURER: WESTERN STATES METAL ROOFING
'SLATE GRAY 24 Ga.
MANUFACTURER: WESTERN STATES METAL ROOFING
4 STANDING SEAM METAL ROOF (B) WESTERN WAVE
METAL RIGID ROOFING 'SLATE GRAY' 24 GA.
MANUFACTURER: WESTERN STATES METAL ROOFING
'SLATE GRAY 24 Ga.
MANUFACTURER: WESTERN STATES METAL ROOFING
7 GLUELAM WOOD SHADE TRELLIS (E)
6 8'-0" HIGH WROUGHT-IRON FENCE
8 STEEL COLUMN (PAINTED PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
9 OPERABLE STORERFONT WINDOW SYSTEM
10 MASONRY WALL AT OUTDOOR STAGE CLAD IN
INDIANA LIMESTONE VENEER (C)
11 MASONRY WALL
12 SERVICE YARD ENCLOSURE (CIP BOARD-FORMED
CONCRETE) (AK) ACCENT MATERIAL. SITE WALLS
13 OPAQUE METAL GATES PAINTED PT-02 (D) PT-02
SHERWIN WILLIAMS 7061 'NIGHT OWL' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
14 ENGINEERED WOOD GATE TO MATCH FENCE
15 SIGNAGE (BY SEPARATE PERMIT)
17 SES (PAINTED PT-01) (H) PT-01 SHERWIN WILLIAMS
9161 'DUSTBLU' SHERWIN WILLIAMS Pro Industrial
Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
18 CABANA BUILDING (SEE ELEVATIONS)
MATERIAL AND FINISH SCHEDULE
SEE SHEET A630 FOR ADDITIONAL DETAIL ON MATERIALS
19 STORERFONT WINDOWS (BRONZE ANODIZED/CLEAR
GLASS)
20 HARIDE PLANK SIDING (F) HARDIE SIDING 'EVENING
BLUE' JAMES HARDIE CEDARMILL SIDING 7.25" X 144"
6" EXPOSURE
MANUFACTURER: JAMES HARDIE COMPANY
22 FDC
23 FIRE RISER ROOM
24 STEEL C CHANNEL (PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
25 STEEL GATES AT SERVICE YARD (PAINTED PT-02) (D)
PT-02 SHERWIN WILLIAMS 7061 'NIGHT OWL'
SHERWIN WILLIAMS Pro Industrial Pro-Cryl Universal
Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
27 GAS FIREPLACE
28 GLUELAM WOOD BEAM (E)
29 TREX CLADDING (G) TREX TRANSCEND IN 'TIKI
TORCH' 5.5" PLANK
MANUFACTURER: TREX COMPANY, INC.
30 GLASS GARAGE DOOR
31 BAR WITH TILE BAR DIE WALL
33 PLATE STEEL SADDLE STRAP (PT-02) (D) PT-02
SHERWIN WILLIAMS 7061 'NIGHT OWL' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
34 ENGINEERED WOOD COLUMN
35 HOLLOW METAL DOOR (PAINTED PT-01) (H) PT-01
SHERWIN WILLIAMS 9161 'DUSTBLU' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
36 STEEL BEAM (PAINTED PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
38 WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE)
39 ADDRESS NUMERALS
40 MECHANICAL UNITS (BEYOND) SCREENED BY
PARAPET
41 CRL GLASS BALUSTRADE SYSTEM
42
PLAZIT 'POLYGAL' 'ICE' CORRUGATED
POLYCARBONAT ROOFING
43
STEEL KNIFE EGDE PARAPET CAP PAINTED PT-02 SW
7601 'NIGHT OWL'
3 3A193
20'-0"9'-0"13'-0"128'-10"
7
GRADE 0'-0"
(EL: 1229.5')6'-0"10'-0"29'-10"22472A 40 23 2220 2A
8'-0"17'-9"2/A2011/A20115
3A
20'-0"25'-0"9'-0"23 22 2A
8'-0"26'-0"
77'-0"
17'-9"
12 1213
2/A2011/A20116'-9"
60'-0"
3
A201
EXTERIOR ELEVATIONS
CONSULTANTS:
CERTIFICATION:Project No.Drawn ByChecked ByDateRevision Date
THIS DRAWING IS PART OF A SET OF WORKING DRAWINGS. THE INFORMATION CONTAINED ON THIS DRAWING MUST BE COORDINATED WITH THE BALANCE OF THE DRAWINGS, AND CANNOT BE TAKEN AS A STAND-ALONE INSTRUCTION. ALL GENERAL NOTES AND SPECIFICATIONS APPLY TO EVERY SHEET IN THIS SET.MXRJEDContact: Paul Frederick12101 S. Crenshaw Blvd. #400Hawthorne, CA 90250paul@eurekarestaurantgroup.com310-331-823211301ELECTRIC PICKLERANCHO CUCAMONGA2024/04/02PLAN CHECK #:CASE #:*For additional information and project requirements and instructions visit www.brickandwest.com/build PLAN CHECK #:__________TRACKING #:__________PROGRESS
DRAWINGS
NOT FOR
CONSTRUCTION
1 MAIN BUILDING ELEVATION - NORTH
3/16" = 1'-0"
MATERIAL AND FINISH SCHEDULE
SEE SHEET A630 FOR ADDITIONAL DETAIL ON MATERIALS
19 STORERFONT WINDOWS (BRONZE ANODIZED/CLEAR
GLASS)
20 HARIDE PLANK SIDING (F) HARDIE SIDING 'EVENING
BLUE' JAMES HARDIE CEDARMILL SIDING 7.25" X 144"
6" EXPOSURE
MANUFACTURER: JAMES HARDIE COMPANY
22 FDC
23 FIRE RISER ROOM
24 STEEL C CHANNEL (PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
25 STEEL GATES AT SERVICE YARD (PAINTED PT-02) (D)
PT-02 SHERWIN WILLIAMS 7061 'NIGHT OWL'
SHERWIN WILLIAMS Pro Industrial Pro-Cryl Universal
Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
27 GAS FIREPLACE
28 GLUELAM WOOD BEAM (E)
29 TREX CLADDING (G) TREX TRANSCEND IN 'TIKI
TORCH' 5.5" PLANK
MANUFACTURER: TREX COMPANY, INC.
30 GLASS GARAGE DOOR
31 BAR WITH TILE BAR DIE WALL
33 PLATE STEEL SADDLE STRAP (PT-02) (D) PT-02
SHERWIN WILLIAMS 7061 'NIGHT OWL' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
34 ENGINEERED WOOD COLUMN
35 HOLLOW METAL DOOR (PAINTED PT-01) (H) PT-01
SHERWIN WILLIAMS 9161 'DUSTBLU' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
36 STEEL BEAM (PAINTED PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
38 WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE)
39 ADDRESS NUMERALS
40 MECHANICAL UNITS (BEYOND) SCREENED BY
PARAPET
41 CRL GLASS BALUSTRADE SYSTEM
42
PLAZIT 'POLYGAL' 'ICE' CORRUGATED
POLYCARBONAT ROOFING
43
STEEL KNIFE EGDE PARAPET CAP PAINTED PT-02 SW
7601 'NIGHT OWL'
2 MAIN BUILDING ELEVATION - NORTH
3/16" = 1'-0"
MATERIAL AND FINISH SCHEDULE
SEE SHEET A630 FOR ADDITIONAL DETAIL ON MATERIALS
2 INDIANA LIMESTONE VENEER (C) SQUARE-CUT
INDIANA LIMESTONE VENEER BUILDING ACCENT
MATERIAL. SITE WALLS
2A CIP BOARD-FORMED CONCRETE (AK)
3 STANDING SEAM METAL (DARK GRAY) (A) WESTERN
WAVE METAL RIGID WALL PANEL 'DARK BRONZE' 24
GA. MANUFACTURER: WESTERN STATES METAL
ROOFING
3A STANDING SEAM METAL (LIGHT GRAY) (B) WESTERN
WAVE METAL RIGID WALL PANEL 'SLATE GRAY' 24 GA.
MANUFACTURER: WESTERN STATES METAL ROOFING
'SLATE GRAY 24 Ga.
MANUFACTURER: WESTERN STATES METAL ROOFING
4 STANDING SEAM METAL ROOF (B) WESTERN WAVE
METAL RIGID ROOFING 'SLATE GRAY' 24 GA.
MANUFACTURER: WESTERN STATES METAL ROOFING
'SLATE GRAY 24 Ga.
MANUFACTURER: WESTERN STATES METAL ROOFING
7 GLUELAM WOOD SHADE TRELLIS (E)
6 8'-0" HIGH WROUGHT-IRON FENCE
8 STEEL COLUMN (PAINTED PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
9 OPERABLE STORERFONT WINDOW SYSTEM
10 MASONRY WALL AT OUTDOOR STAGE CLAD IN
INDIANA LIMESTONE VENEER (C)
11 MASONRY WALL
12 SERVICE YARD ENCLOSURE (CIP BOARD-FORMED
CONCRETE) (AK) ACCENT MATERIAL. SITE WALLS
13 OPAQUE METAL GATES PAINTED PT-02 (D) PT-02
SHERWIN WILLIAMS 7061 'NIGHT OWL' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
14 ENGINEERED WOOD GATE TO MATCH FENCE
15 SIGNAGE (BY SEPARATE PERMIT)
17 SES (PAINTED PT-01) (H) PT-01 SHERWIN WILLIAMS
9161 'DUSTBLU' SHERWIN WILLIAMS Pro Industrial
Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
18 CABANA BUILDING (SEE ELEVATIONS)
34119413A2
184'-6"
GRADE 0'-0"
(EL: 1229.5')12'-0"12'-0"10'-0"29'-10"25'-0"242 743
184'-6"12'-0"12'-0"10'-0"29'-10"13'-6"25'-0"242 7
1/A2022/A2022919 242424
2
GRADE 0'-0"
(EL: 1229.5')
2A
1/A2022/A2022194019242424243
8'-0"25'-0"A202
EXTERIOR ELEVATIONS
CONSULTANTS:
CERTIFICATION:Project No.Drawn ByChecked ByDateRevision Date
THIS DRAWING IS PART OF A SET OF WORKING DRAWINGS. THE INFORMATION CONTAINED ON THIS DRAWING MUST BE COORDINATED WITH THE BALANCE OF THE DRAWINGS, AND CANNOT BE TAKEN AS A STAND-ALONE INSTRUCTION. ALL GENERAL NOTES AND SPECIFICATIONS APPLY TO EVERY SHEET IN THIS SET.MXRJEDContact: Paul Frederick12101 S. Crenshaw Blvd. #400Hawthorne, CA 90250paul@eurekarestaurantgroup.com310-331-823211301ELECTRIC PICKLERANCHO CUCAMONGA2024/04/02PLAN CHECK #:CASE #:*For additional information and project requirements and instructions visit www.brickandwest.com/build PLAN CHECK #:__________TRACKING #:__________PROGRESS
DRAWINGS
NOT FOR
CONSTRUCTION
1 MAIN BUILDING ELEVATION - SOUTH
3/16" = 1'-0"
MATERIAL AND FINISH SCHEDULE
SEE SHEET A630 FOR ADDITIONAL DETAIL ON MATERIALS
2 INDIANA LIMESTONE VENEER (C) SQUARE-CUT
INDIANA LIMESTONE VENEER BUILDING ACCENT
MATERIAL. SITE WALLS
2A CIP BOARD-FORMED CONCRETE (AK)
3 STANDING SEAM METAL (DARK GRAY) (A) WESTERN
WAVE METAL RIGID WALL PANEL 'DARK BRONZE' 24
GA. MANUFACTURER: WESTERN STATES METAL
ROOFING
3A STANDING SEAM METAL (LIGHT GRAY) (B) WESTERN
WAVE METAL RIGID WALL PANEL 'SLATE GRAY' 24 GA.
MANUFACTURER: WESTERN STATES METAL ROOFING
'SLATE GRAY 24 Ga.
MANUFACTURER: WESTERN STATES METAL ROOFING
4 STANDING SEAM METAL ROOF (B) WESTERN WAVE
METAL RIGID ROOFING 'SLATE GRAY' 24 GA.
MANUFACTURER: WESTERN STATES METAL ROOFING
'SLATE GRAY 24 Ga.
MANUFACTURER: WESTERN STATES METAL ROOFING
7 GLUELAM WOOD SHADE TRELLIS (E)
6 8'-0" HIGH WROUGHT-IRON FENCE
8 STEEL COLUMN (PAINTED PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
9 OPERABLE STORERFONT WINDOW SYSTEM
10 MASONRY WALL AT OUTDOOR STAGE CLAD IN
INDIANA LIMESTONE VENEER (C)
11 MASONRY WALL
12 SERVICE YARD ENCLOSURE (CIP BOARD-FORMED
CONCRETE) (AK) ACCENT MATERIAL. SITE WALLS
13 OPAQUE METAL GATES PAINTED PT-02 (D) PT-02
SHERWIN WILLIAMS 7061 'NIGHT OWL' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
14 ENGINEERED WOOD GATE TO MATCH FENCE
15 SIGNAGE (BY SEPARATE PERMIT)
17 SES (PAINTED PT-01) (H) PT-01 SHERWIN WILLIAMS
9161 'DUSTBLU' SHERWIN WILLIAMS Pro Industrial
Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
18 CABANA BUILDING (SEE ELEVATIONS)
MATERIAL AND FINISH SCHEDULE
SEE SHEET A630 FOR ADDITIONAL DETAIL ON MATERIALS
19 STORERFONT WINDOWS (BRONZE ANODIZED/CLEAR
GLASS)
20 HARIDE PLANK SIDING (F) HARDIE SIDING 'EVENING
BLUE' JAMES HARDIE CEDARMILL SIDING 7.25" X 144"
6" EXPOSURE
MANUFACTURER: JAMES HARDIE COMPANY
22 FDC
23 FIRE RISER ROOM
24 STEEL C CHANNEL (PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
25 STEEL GATES AT SERVICE YARD (PAINTED PT-02) (D)
PT-02 SHERWIN WILLIAMS 7061 'NIGHT OWL'
SHERWIN WILLIAMS Pro Industrial Pro-Cryl Universal
Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
27 GAS FIREPLACE
28 GLUELAM WOOD BEAM (E)
29 TREX CLADDING (G) TREX TRANSCEND IN 'TIKI
TORCH' 5.5" PLANK
MANUFACTURER: TREX COMPANY, INC.
30 GLASS GARAGE DOOR
31 BAR WITH TILE BAR DIE WALL
33 PLATE STEEL SADDLE STRAP (PT-02) (D) PT-02
SHERWIN WILLIAMS 7061 'NIGHT OWL' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
34 ENGINEERED WOOD COLUMN
35 HOLLOW METAL DOOR (PAINTED PT-01) (H) PT-01
SHERWIN WILLIAMS 9161 'DUSTBLU' SHERWIN
WILLIAMS Pro Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
36 STEEL BEAM (PAINTED PT-02) (D) PT-02 SHERWIN
WILLIAMS 7061 'NIGHT OWL' SHERWIN WILLIAMS Pro
Industrial Pro-Cryl Universal Primer with
two coats of Pro Industrial Multi-Surface Acrylic Gloss
38 WALL MOUNTED LIGHT FIXTURE (SEE SCHEDULE)
39 ADDRESS NUMERALS
40 MECHANICAL UNITS (BEYOND) SCREENED BY
PARAPET
41 CRL GLASS BALUSTRADE SYSTEM
42
PLAZIT 'POLYGAL' 'ICE' CORRUGATED
POLYCARBONAT ROOFING
43
STEEL KNIFE EGDE PARAPET CAP PAINTED PT-02 SW
7601 'NIGHT OWL'
2 MAIN BUILDING ELEVATION - SOUTH
3/16" = 1'-0"
DESIGN REVIEW COMMENTS
May 7, 2024
6:00 p.m.
Adam Pisarkiewicz, Contract Planner
DESIGN REVIEW – BISHOP VENTURES – A request to construct a multi-family residential
development comprising 145 residential units on 2.72 acres of land at the northeast corner of
Foothill Boulevard and Lion Street in the Corridor 1 (CO1) Zone. APN: 0208-632-47 (DRC2022-
00354).
Site Characteristics:
The 2.72-acre project site is located at the northeast corner of Foothill Boulevard and Lion Street.
The site is currently vacant and has been so for decades. The dimensions of the roughly square
project site are approximately 290 feet from north to south and 408 feet from east to west. The
site is flat with minimal grade change.
Background:
The applicant submitted an SB 330 preliminary application on September 20, 2022 (followed by
a timely full application), which vested the project to applicable development standards in place
at the time in accordance with state law.
The Land Use, General Plan, and Zoning Designations for the project site and adjacent properties
are as follows:
Table 1: Surrounding Land Use and Zoning Context
In addition to the SB 330 application, the applicant also proposes to utilize State Density Bonus
Law (SDBL) and will preserve 11% of the residential units (12 units) for very low-income
households. Pursuant to State Density Bonus Law (SDBL), the applicant is requesting waivers
from various development standards. A full discussion of waivers will be provided to the Planning
Commission at the appropriate time.
Project Design and Layout:
The project is comprised of one 4-story residential building with an interior courtyard/pool area,
pocket park, dog park, and surface parking. Parking is provided in surface lots and private garages
on the first floor of the residential building, and off-street parking along a new frontage lane on
Foothill Boulevard and Lion Street. The new frontage lane and on-street parking creates a buffer
between the units, the pocket park, dog park, and vehicle traffic. This configuration effectuates
the General Plan’s vision to improve the pedestrian realm along the City’s primary corridors.
Land Use General Plan Zoning
Site Vacant City Corridor Moderate Corridor 1 (CO-1)
North Single-Family
Residences
Suburban Neighborhood –
Very Low Low Residential (L)
South Multi-Family
Residences City Corridor Moderate Corridor 1 (CO-1)
East Commercial (Auto
Repair) City Corridor Moderate Corridor 1 (CO-1)
West Commercial
Shopping Center City Corridor Moderate Corridor 1 (CO-1)
DRC COMMENTS
DR DRC2022-00354 – BISHOP VENTURES
May 7, 2024
Page 2
Figure 1: Site Plan
Architecture:
The project’s exterior design is considered contemporary. The proposed building provides a flat
roof with varying rooflines, large open corner elements, and undulating building facades to help
break up the building massing and provide visual interest. Building materials include concrete,
plaster, and metal railings on balconies.
Figure 2: View from corner from Foothill Boulevard and Lion Street.
DRC COMMENTS
DR DRC2022-00354 – BISHOP VENTURES
May 7, 2024
Page 3
Figure 3: View from Lion Street of the rear of the project site.
Unit Composition and Floor Plans:
The project is comprised of 145 elevator-served residential units that are all single-level except
for 11 units which include mezzanines. The table below summarizes the number of residential
units and square feet of each unit:
UNIT SUMMARY
Residential
Unit Type Unit Size (SF - Net) Number of Units
Studio 361-510 SF 19
1 Bedroom 508 to 883 SF 64
2 Bedroom 804 to 1,161 SF 62
Total Number of Units 145
Recreational Amenities:
Resident amenities include the following:
• Pool with lounge seating areas
• Indoor Lounge
• Dog park
• Bike Storage Facility with 40 long-term racks
• Interior pocket park with bench seating
• Leasing office
Public Amenities:
The project provides one pocket park on the southwest corner of the property and one dog park
in the southeast corner of the property. The project also provides ten short-term bike racks.
Compliance with Development Standards:
As noted, the applicant has requested waivers from various development standards through State
Density Bonus Law (SDBL). Under the SDBL, a “waiver” is intended to modify or reduce
applicable development standards that would have the effect of physically precluding the
construction of the proposed density bonus units or the developer’s requested concession or
incentive. See below for the project’s compliance with relevant development standards.
DRC COMMENTS
DR DRC2022-00354 – BISHOP VENTURES
May 7, 2024
Page 4
COMPLIANCE TABLE
Development Standard Required Proposed Complies
Residential Density 42 DU/AC max. 57 DU/AC YES*
Non-Residential
Intensity/FAR (General
Plan)
0.4-1.0 0 WAIVER
Setbacks (CO-1) Variable Variable YES
Building Height (CO-1) 5 stories max. 4 stories YES
Landscape Area 10% min. 30% YES
Open Space 10,780 SF (30 SF/Unit) 14,220 SF YES
*State Density Bonus Law allows for developments to exceed the maximum units per acre standard
On-Site Parking, On-Street Parking, and Foothill Boulevard Frontage Lane:
Regarding parking, the project proposes 185 on-site parking spaces to serve the residential units.
As a result of parking reductions afforded to the project through SDBL, these 185 parking spaces
exceeds the minimum number of required parking spaces for the project which would be 176.
The applicant is providing 19 on-street parking spaces to serve the development. Specifically, this
on-street parking comprises 11 clear-view parking spaces along the frontage lane parallel to
Foothill Boulevard, separated from Foothill Boulevard via a new landscaped median, and 8
parallel parking spaces along Lion Street. The figure below displays the locations of the frontage
lane and off-street spaces for reference:
DRC COMMENTS
DR DRC2022-00354 – BISHOP VENTURES
May 7, 2024
Page 5
Figure 4: Site Plan, displaying the proposed frontage lane and off-street parking areas circled in red.
Staff Recommendation: The project meets the City’s vision for a high-density residential
development within the underlying zone, in terms of walkability, pedestrian connections, and the
public realm.
Staff requests that the Design Review Committee consider the design (building architecture, site
planning, etc.) of the proposed project and recommend the selected action below:
☒Recommend Approval of the design of the project as proposed by the applicant.
☐Recommend Approval with Modifications to the design of the project by incorporating
revisions requested by the Committee. Follow-up review by the Committee is not required. The
revisions shall be verified by staff prior to review and action by the Planning Director / Planning
Commission.
☐Recommend Conditional Approval of the design of the project by incorporating revisions
requested by the Committee. Follow-up review by the Committee is not required. The revisions
shall be Conditions of Approval and verified by staff during plan check after review and action by
the Planning Director / Planning Commission.
☐Recommend Denial of the design of the project as proposed by the applicant.
DRC COMMENTS
DR DRC2022-00354 – BISHOP VENTURES
May 7, 2024
Page 6
Design Review Committee Action:
Staff Planner: Adam Pisarkiewicz, Contract Planner
Members Present:
Staff Coordinator: Sean McPherson, Principal Planner
Exhibit A – Architecture Plans
L LOW RESIDENTIAL
M MEDIUM RESIDENTIAL
OS OPEN SPACE
NI NEO INDUSTRIAL
CO-1 CORRIDOR 1 ZONE
GI GENERAL INDUSTRIAL
CE1 CENTER 1 ZONE
SITE: CO-1 CORRIDOR 1 ZONE
SITE
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
COVER SHEET / PROJECT DATA
G001G001Lion's Gate Multi-family Development
LION'S GATE
DEVELOPER
LIONS GATE PARTNERS LLC.
Contact: Gilman Bishop
Address: 2050 Hancock St., Suite B
San Diego, CA 92110
T: 619.746.5191
Email: gbishop@bishopventures.com
ARCHITECT
DESIGNARC LA, INC.
Contact: Mark Kirkhart
Address: 2558 Overland Avenue
Los Angeles, CA 90064
T: 310.204.8950
Email: mkirkhart@designarc.net
CIVIL ENGINEER
MADOLE ASSOCIATES, INC.
Contact: Mark Bertone
Address: 9302 Pittsburgh Ave., Suite 230
Rancho Cucamonga, CA 91730
T: 909.481.6322 x 116
Email: mbertone@madoleinc.com
LANDSCAPE ARCHITECT
GMP
Contact: John Patterson
Address: 3176 Lionshead Ave. #102
Carlsbad, CA 92010
T: 858.558.8977
Email: john@gmplandarch.com
ADDRESS:
NE Corner of Foothill Blvd and Lion St, Rancho Cucamonga, CA 91730
APN: 0208-632-47-0000
BUILDING TYPE: V-A 4 Stories
LOT SIZE: 2.72 acres (Gross)
2.54 acres (Net)
ZONING: CO-1 Corridor 1 Zone
SUPPLEMENTAL ZONING: Corridor Fronting Residential
GENERAL PLAN: City Corridor Moderate
EXISTING USE: Vacant Lot
GENERAL
G001 - COVER SHEET / PROJECT DATA
G002 - SDBL / ZONING STANDARDS
ARCHITECTURE
A101 - FIRST FLOOR PLAN
A102 - SECOND FLOOR PLAN
A103 - THIRD FLOOR PLAN
A104 - FOURTH FLOOR PLAN
A105 - LOFTS & ROOF PLAN
A106 - TOP ROOF PLAN
A201 - BUILDING ELEVATIONS
A202 - BUILDING ELEVATIONS
A203 - BIKE ROOM ELEVATIONS
A204 - CARPORT ELEVATIONS
A301 - SECTIONS
A401 - UNIT PLANS
A402 - UNIT PLANS
A403 - UNIT PLANS
A404 - UNIT PLANS
A405 - UNIT PLANS
A406 - UNIT PLANS
A501 - RENDERING
A502 - RENDERING
A503 - RENDERING
A504 - RENDERING
A601 - MATERIAL BOARD
LANDSCAPE
L01 - LANDSCAPE CONCEPT PLAN
L02 - LANDSCAPE CONCEPT
ENLARGEMENTS
L03 - LANDSCAPE CONCEPTUAL
IRRIGATION PLAN
L04 - LANDSCAPE FENCE & WALL PLAN
CIVIL
CF-01 CUT-FILL MAP
CG-01 CONCEPTUAL GRADING
CG-02 CONCEPTUAL GRADING SECTIONS
CU-01 CONCEPTUAL UTILITY PLAN
FA-01 FIRE ACCESS EXHIBIT
SP-01 SITE PLAN
SUM-01 SITE UTILIZATION MAP
WQ-01 PRELIMINARY WATER QUALITY
MANAGEMENT PLAN
The project consists of a new proposed multi-family housing development located on the North East corner of Foothill Boulevard and Lion Street within the
Corridor 1 (CO-1) Zoning District. The development includes 145 residential apartment units of which 12 will be very low income rent restricted and which
utilizes the State Density Bonus Law (SDBL) with 11% of base density units being provided as very low Income rent restricted units onsite. The unit mix
includes (19) Studios, (64) One-Bedroom, and (62) Two-Bedroom units with a combination of flats, townhomes, and units with mezzanines, with an
average size of 703 square feet and 166 parking spaces (surface, covered, or tandem configuration). An additional 19 spaces off-site for a total of 185 are
being provided with the public street improvements along both Foothill Blvd and Lion St. The proposed density on the parcel, including the SDBL units, will
be 57.1 dwelling units per acre (net) / 53.3 dwelling units per acre (gross).
VICINITY MAP
SITE UTILIZATION MAP
SHEET INDEXPROJECT INFORMATION
PROJECT DESCRIPTION
PROJECT DATA
UNIT COUNT AND PARKING INFORMATION
PROJECT TEAM
PARKING CALCULATIONS
COVER SHEET / PROJECT DATA
SDBL ELIGIBILTY:
With the inclusion of the SDBL 11% Very-low-income units,
the Applicant team is eligible for up too (2) Incentives, as well
as an unlimited number of Waivers. This project proposes to
use (1) of the Incentives and (11) Waivers. The unused 2nd
Incentive shall be reserved.
PRIVATE OPEN SPACE
NUMBER OF UNITS WITH
COMPLIANT BALCONIES
NUMBER OF UNITS WITHOUT
COMPLIANT BALCONIES
NUMBER OF UNITS WITHOUT
BALCONIES
NUMBER OF UNITS WITH
NON-COMPLIANT BALCONIES
TOTAL NUMBER OF UNITS
% OF UNIT WITH COMPLIANT
BALCONIES
121
24
3
21
145
83%
Exhibit A
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
SDBL / ZONING STANDARDS
G002G002Lion's Gate Multi-family Development SDBL / ZONING STANDARDS
STATE DENSITY BONUS LAW SUMMARYBUILDING TYPE STANDARDS (MID-RISE BUILDING)
SMALL FRONT YARD, PORCH AND STOOP VARIATIONS CORRIDOR 1 (CO1)PUBLIC OPEN SPACE STANDARDS (POCKET PARK)
ZONING DISTRICT STANDARDS CORRIDOR 1 (CO1)
BUILDING ENTRANCE AND FACADE TYPE STANDARDS
(GALLERY & ARCADE VARIATION)
RESIDENTIAL
LOADING ZONE)MOTORCYCLEFOOTHILL BOULEVARDLION STREETCARPORTCARPORT CARPORT CARPORT
CARPORTCARPORT1BR-C1BR-C1BR-CST-C
1BR-C1BR-C1BR-CST-C
STAIR 1
LOBBY
AMENITY
2BR-B-GF
1BR-B-GF1BR-B-GF 1BR-B-GF
2BR-A
1BR-B-GF 2BR-B-GF
ST-C ST-C 1BR-C 1BR-C
ST-C 1BR-C 1BR-CST-C
MECH.
STORAGE
1BR-E2
1BR-D2
1BR-A-GF
2BR-A2
MECH.
2BR-B22BR-A2
2BR-A2
1BR-D2
TRASH
MECH.
STAIR 2
A201
1
A202
1
A202
2
A201
2
SEE LANDSCAPE
DRAWINGS
1BR-D3
STAIR 3
(E) PROPERTY LINE
ASSUMED (N) PROPERTY LINE
GARAGE
GARAGE
GARAGE
GARAGE
GARAGE
GARAGE
GARAGE
GARAGE
GARAGE
GARAGEGARAGEGARAGEGARAGEGARAGEGARAGE
96' - 7"
SEE LANDSCAPE
DRAWINGS
1234
5678
9
10
1112 13
14
15
16
17 18 19 20
212223242526272829
3231 30
A301
1
LOUNGE
MAIL /
PARCEL ROOM
STO.
LEASING
OFFICE
LEASING
OFFICE
LOCKABLE GARAGES
WITH SPACE FOR
STORAGE
GALLERY AND ARCADE VARIATION
ENTRANCE
ELEVATORS
A301
2
11' - 3"12' - 1"330' - 0"192' - 0"11' - 3"24' - 6"59' - 2"9' - 2"31' - 9"15' - 0"15' - 0"15' - 0"
BUILD-TO LINE1' - 7"11' - 0"5' - 6"70' - 10"13' - 4"
20' - 0"TYP.10' - 0"PROJECTION ABOVE16' - 3"16' - 9"14' - 10"BIKE RACK, TYP.
(10 SHORT-TERM BIKE
PARKING SPACES IN TTL)
BIKE STORAGE ROOM
(40 LONG-TERM BIKE
PARKING SPACES)15' - 0"PROJECTION ABOVE
4' - 0"9' - 6"PROJECTION
ENTRANCE
SCALE: 3/32" = 1' - 0"
0 4 8 241612
NORTH
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
1ST FLOOR PLAN
A101A101Lion's Gate Multi-family Development 1ST FLOOR PLAN
1BR-C1BR-C1BR-CST-B
1BR-C1BR-C1BR-CST-B
STAIR 1
1BR-D4
2BR-B
1BR-B
2BR-A
2BR-B
ST-C ST-C 1BR-C 1BR-C
ST-C 1BR-C 1BR-CST-D
MECH.STORAGE
1BR-E
1BR-D1
2BR-A
2BR-A
MECH.
2BR-B2BR-A
2BR-A
1BR-D1
TRASH
STORAGE
STAIR 2
ST-A2
STORAGE
1BR-B 1BR-B 1BR-B
IDF
2BR-A
1BR-E
ST-A1
2BR-B
1BR-B
2BR-B
2BR-B
1BR-B
2BR-B
1BR-B2BR-B1BR-B2BR-BST-A1
A201
1
A202
1
A202
2
A201
2
STAIR 3
33
34
59
60
6162 63
64
65
66
47
5152535455
57
68 67
35
36
37
38
3940 41 42 43
44
45
46
56
58
48
4950
A301
1
ELEVATORS
69
A301
2
9' - 7"SCALE: 3/32" = 1' - 0"
0 4 8 241612
NORTH
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
2ND FLOOR PLAN
A102A102Lion's Gate Multi-family Development 2ND FLOOR PLAN
2BR-C1BR-F
STAIR 1
2BR-B
2BR-B
1BR-B
2BR-A
2BR-B 1BR-F
2BR-C
MECH.STORAGE
1BR-E
1BR-D1
2BR-A
MECH.
2BR-B2BR-A
2BR-A
1BR-D1
TRASH
STORAGE
STAIR 2
STORAGE
1BR-B 1BR-B 1BR-B
IDF
2BR-A
1BR-E
ST-A1
2BR-B
2BR-B
1BR-B2BR-B1BR-B2BR-BST-A1
2BR-C1BR-F
1BR-B
2BR-C
A201
1
A202
1
A202
2
A201
2
STAIR 3
70
97
98
99100 101
102
103
104
87 88
899091929394
107106 105
7172
74
75
7980 81 82 83
84
85
96
A301
1
1BR-B
1BR-B
2BR-B
2BR-B
18' - 4"6' - 0"18' - 4"6' - 0"6' - 4"16' - 3"2BR-A
6' - 1"18' - 11"22' - 0"6' - 0"6' - 1"22' - 4"6' - 1"15' - 6"
6' - 1"15' - 10"15' - 10"6' - 1"
ELEVATORS
18' - 11"19' - 1"6' - 1"
22' - 4"
76
77
78
6' - 1"15' - 10"6' - 0"73
86
95
A301
2
SCALE: 3/32" = 1' - 0"
0 4 8 241612
NORTH
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
3RD FLOOR PLAN
A103A103Lion's Gate Multi-family Development 3RD FLOOR PLAN
2BR-C1BR-F
W/ Mezzanine
STAIR 1
2BR-B
W/ Mezzanine
2BR-B
1BR-B
W/ Mezzanine
2BR-A
2BR-B
W/ Mezzanine
1BR-F
W/ Mezzanine
2BR-C
MECH.STORAGE
1BR-E
1BR-D1
2BR-A
2BR-A
MECH.
2BR-B2BR-A
2BR-A
1BR-D1
TRASH
STORAGE
STAIR 2
STORAGE
1BR-B
W/ Mezzanine
1BR-B
W/ Mezzanine 1BR-B
IDF
2BR-A
1BR-E
ST-A1
2BR-B
2BR-B
1BR-B2BR-B1BR-B2BR-BST-A1
2BR-C1BR-F
1BR-B
2BR-C
A201
1
A202
1
A202
2
A201
2
STAIR 3
110109
111112
135
136
137138 139
140
141
142 124
125 126
127128129130131132133
144 143
113
114
115
116
117118 119 120 121
122
123
108
134
A301
1
1BR-B
W/ Mezzanine
1BR-B
W/ Mezzanine
2BR-B
W/ Mezzanine
2BR-B
W/ Mezzanine
22' - 0"5' - 10"6' - 0"
6' - 0"19' - 1"6' - 0"14' - 4"6' - 0"15' - 8"6' - 0"18' - 9"22' - 0"
15' - 10"6' - 0"ELEVATORS
15' - 10"6' - 0"37' - 1"6' - 4"15' - 10"
22' - 4"19' - 1"6' - 0"15' - 10"15' - 6"6' - 0"145
A301
2
SCALE: 3/32" = 1' - 0"
0 4 8 241612
NORTH
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
4TH FLOOR PLAN
A104A104Lion's Gate Multi-family Development 4TH FLOOR PLAN
A201
1
A202
1
A202
2
A201
2
A301
11BR-F
W/ Mezzanine
2BR-B
W/ Mezzanine
1BR-B
W/ Mezzanine
2BR-B
W/ Mezzanine
1BR-F
W/ Mezzanine
1BR-B
W/ Mezzanine
1BR-B
W/ Mezzanine
1BR-B
W/ Mezzanine
1BR-B
W/ Mezzanine
2BR-B
W/ Mezzanine
2BR-B
W/ Mezzanine
4' - 0" HIGH EQUIPMENT SCREEN
4' - 0" HIGH EQUIPMENT SCREEN
A301
2
SCALE: 3/32" = 1' - 0"
0 4 8 241612
NORTH
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
LOFTS & ROOF PLAN
A105A105Lion's Gate Multi-family Development LOFTS & ROOF PLAN
A201
1
A202
1
A202
2
A201
2
A301
1
A301
2
SCALE: 3/32" = 1' - 0"
0 4 8 241612
NORTH
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
TOP ROOF PLAN
A106A106Lion's Gate Multi-family Development 4TH FLOOR PLAN
Level 1
0' - 0"
Level 3
23' - 6"
Level 2
13' - 3"
Level 4
33' - 9"
Mezzanine
44' - 0"
Roof Level
54' - 3"
M-1
P-3
PL-1
P-1
DW-1 MT-1
P-5
PL-1
P-2
PL-1
P-4
DW-2
CN-1
DW-3
M-2
P-2
LA-1
LA-1
DW-2
MAX. ZONING HEIGHT
76' - 3"92' - 0"
M-1
P-3
10' - 3"10' - 3"10' - 3"10' - 3"13' - 3"BUILDING HEIGHT (MAX 92')54' - 3"24' - 0"21' - 2"18' - 4"21' - 5"18' - 4"10' - 1"18' - 4"10' - 6"18' - 5"21' - 4"36' - 4"10' - 6"39' - 6"10' - 9"18' - 3"21' - 2"24' - 0"
ARCHITECTURAL PROJECTION OVER LOBBY ENTRANCEGALLERY AND
ARCADE VARIATION
ENTRANCE
CORNER ELEMENT CORNER ELEMENT
ENTRANCE HEIGHT12' - 0"HEIGHT, WALL AT FRONTAGE3' - 0"22' - 0"PORCH VARIATION: HEIGHT12' - 0"COLUMN HEIGHT11' - 0"Level 1
0' - 0"
Level 3
23' - 6"
Level 2
13' - 3"
Level 4
33' - 9"
Mezzanine
44' - 0"
Roof Level
54' - 3"10' - 3"10' - 3"10' - 3"10' - 3"13' - 3"BUILDING HEIGHT54' - 3"DW-4
P-5
M-1
P-3
PL-1
P-1
DW-1 MT-1
P-5
PL-1
P-2
PL-1
P-4
DW-2
DW-3
M-2
P-2
LA-1
MAX. ZONING HEIGHT
76' - 3"92' - 0"37' - 9"30' - 6"6' - 0"30' - 6"10' - 5"16' - 3"10' - 3"18' - 4"21' - 5"18' - 4"10' - 4"29' - 1"
PROJECTION ENTRANCE12' - 0"PROJECTION OVER ENTRY
KEY PLAN-
2
-
1
SCALE: 3/32" = 1' - 0"
0 4 8 241612
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
SOUTH & WEST ELEVATIONS
A201A201Lion's Gate Multi-family Development
3/32" = 1'-0"A201
1SOUTH ELEVATION
3/32" = 1'-0"A201
2WEST ELEVATION
KEYNOTES
CONCRETE
CN-1 CMU concrete site wall.
PLASTER
PL-1 Exterior plaster.
METALS
MT-1 Perforated metal guardrail, painted.
MISCELLANEOUS
M-1 6" Horizontal cementitious siding, painted.
M-2 Metal carports, painted.
PAINT / STAIN
P-1 Snowbound-SW 7004
P-2 Passive-SW 7064
P-3 Gray Matters-SW 7066
P-4 Cityscape-SW 7067
P-5 Peppercorn-SW 7674
LANDSCAPE
LA-1 Landscaping & irrigation
DOORS, WINDOWS, & FRAMES
DW-1 Milgard or equal vinyl windows, silver finish.
DW-2 Milgard or equal vinyl sliding doors, silver finish.
DW-3 Clear anodized aluminum storefront system.
DW-4 Aluminum garage door, painted or integral.
SOUTH & WEST ELEVATIONS
DRB 05-02-2024
Level 1
0' - 0"
Level 3
23' - 6"
Level 2
13' - 3"
Level 4
33' - 9"
Mezzanine
44' - 0"
Roof Level
54' - 3"10' - 3"10' - 3"10' - 3"10' - 3"13' - 3"BUILDING HEIGHT (MAX 92')54' - 3"M-1
P-3
PL-1
P-1
DW-1MT-1
P-5
PL-1
P-2
PL-1
P-4
DW-2
DW-3 DW-4
P-5
LA-1PL-1
P-4
MAX. ZONING HEIGHT
76' - 3"92' - 0"37' - 9"30' - 7"26' - 11"16' - 7"10' - 3"18' - 5"21' - 4"18' - 4"10' - 7"28' - 8"6' - 4"30' - 7"
15' - 3"11' - 8"12' - 0"Level 1
0' - 0"
Level 3
23' - 6"
Level 2
13' - 3"10' - 3"10' - 3"10' - 3"10' - 3"13' - 3"Level 4
33' - 9"
Mezzanine
44' - 0"
Roof Level
54' - 3"BUILDING HEIGHT (MAX 92')54' - 3"M-1
P-3
PL-1
P-1
DW-1 MT-1
P-5PL-1
P-2
DW-2
LA-1
DW-3
DW-4
P-5
PL-1
P-4
PL-1
P-1
DW-2
MT-1
P-5
M-1
P-3
MAX. ZONING HEIGHT
76' - 3"92' - 0"37' - 9"M-1
P-3
29' - 0"10' - 4"18' - 4"21' - 4"18' - 5"10' - 0"17' - 6"30' - 6"6' - 0"30' - 6"12' - 0"KEY PLAN -
2
-
1
SCALE: 3/32" = 1' - 0"
0 4 8 241612
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
NORTH & EAST ELEVATION
A202A202Lion's Gate Multi-family Development
3/32" = 1'-0"A202
1NORTH ELEVATION
3/32" = 1'-0"A202
2EAST ELEVATION
KEYNOTES
CONCRETE
CN-1 CMU concrete site wall.
PLASTER
PL-1 Exterior cement plaster.
METALS
MT-1 Perforated metal guardrail, painted.
MISCELLANEOUS
M-1 6" Horizontal cementitious siding, painted.
M-2 Metal carport Carports, painted.
PAINT / STAIN
P-1 Snowbound-SW 7004
P-2 Passive-SW 7064
P-3 Gray Matters-SW 7066
P-4 Cityscape-SW 7067
P-5 Peppercorn-SW 7674
LANDSCAPE
LA-1 Landscaping & irrigation
DOORS, WINDOWS, & FRAMES
DW-1 Milgard or equal vinyl windows, silver finish.
DW-2 Milgard or equal vinyl sliding doors, silver finish.
DW-3 Clear anodized aluminum storefront system.
DW-4 Aluminum garage door, painted or integral.
NORTH & EAST ELEVATIONS
DRB 05-02-2024
10' - 6"24' - 0"
FFE PER CIVIL
10' - 11"22' - 6"10' - 6"FFE PER CIVIL 10' - 11"24' - 0"
FFE PER CIVIL10' - 6"22' - 6"10' - 11"FFE PER CIVIL
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
BIKE ROOM ELEVATIONS
A203A203Lion's Gate Multi-family Development BIKE ROOM ELEVATIONS
1/4" = 1'-0"A203
3 BIKE ROOM EAST ELEVATION
1/4" = 1'-0"A203
2BIKE ROOM NORTH ELEVATION
1/4" = 1'-0"A203
1 BIKE ROOM WEST ELEVATION
1/4" = 1'-0"A203
4BIKE ROOM SOUTH ELEVATION
Level 1
0' - 0"
72' - 0"8' - 11"FFE LEVEL PER CIVIL
Level 1
0' - 0"8' - 11"17' - 8"
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
CARPORT ELEVATIONS
A204A204Lion's Gate Multi-family Development CARPORT ELEVATIONS
1/4" = 1'-0"A204
1CARPORT FRONT
1/4" = 1'-0"A204
2CARPORT SIDE
Level 1
0' - 0"
Level 3
23' - 6"
Level 2
13' - 3"
Level 4
33' - 9"
Mezzanine
44' - 0"
Roof Level
54' - 3"10' - 3"10' - 3"10' - 3"10' - 3"13' - 3"BUILDING HEIGHT (MAX 92')54' - 3"MAX. ZONING HEIGHT
76' - 3"37' - 9"92' - 0"
EQUIPMENT SCREEN
TYP.4' - 0"GROUND FLOOR HEIGHT12' - 0"Level 1
0' - 0"
Level 3
23' - 6"
Level 2
13' - 3"
Level 4
33' - 9"
Mezzanine
44' - 0"
Roof Level
54' - 3"10' - 3"10' - 3"10' - 3"10' - 3"13' - 3"BUILDING HEIGHT (MAX 92')54' - 3"MAX. ZONING HEIGHT
76' - 3"37' - 9"92' - 0"
95' - 11"
6' - 6"PROPERTY LINETYP.4' - 0"EQUIPMENT SCREEN RTU TYP.
72' - 10"23' - 1"
63' - 3"9' - 7"11' - 0"12' - 1"
KEY PLAN
-
1-2SCALE: 3/32" = 1' - 0"
0 4 8 241612
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
SECTIONS
A301A301Lion's Gate Multi-family Development
3/32" = 1'-0"A301
1SECTION 1
3/32" = 1'-0"A301
2SECTION 2
SECTIONS
W/DW/DUP
DN
W/DW/DUP
DN
29' - 9"42" CLR18" CLR
18" CLR 42" CLR44" CLR18" CLR42" CLR18" CLR
24" CLR MIN
5' - 0"9' - 11"6' - 4"8' - 8"6' - 9"14' - 4"To Patio
30"
DW
30x4830x48
30x48
2' - 6"W/D30x48
30x48BATHROOM
KITCHEN
BEDROOM LIVING ROOM
27' - 3 3/8"32' - 0"
10' - 9"
10' - 11"11' - 2"DW30x4830x4830x4830x4830"44" CLR18" CLR
24" CLR MIN
30x48
3
0
x
4
8
To Balcony
28' - 10"
14' - 4"3' - 7"10' - 11"24' - 0"8' - 1"15' - 11"42" CLR
18" CLR42" CLR
18" CLR42" CLR18" CLR
KITCHEN
LIVING ROOM
BATHROOM
BEDROOM 17' - 6"DWOPEN TO BELOW
14' - 2"6' - 6"10' - 6"
LIVING ROOM
To Balcony
KITCHEN
LIVING ROOM
BATHROOM
BEDROOM
24' - 0"44" CLR18" CLR
18" CLR
42" CLR18" CLR42" CLR28' - 10"
13' - 3"3' - 9"11' - 10"7' - 10"4' - 10"11' - 4"16' - 10"12' - 0"
24" CLR MIN
30x48
3
0
x
4
8DW
30x4830x4830x4830x4830"To Patio
KITCHEN
LIVING ROOM
BATHROOM
BEDROOM
24' - 0"44" CLR18" CLR
18" CLR
42" CLR18" CLR42" CLR28' - 10"
13' - 3"3' - 9"11' - 10"7' - 10"4' - 10"11' - 4"16' - 10"12' - 0"
24" CLR MIN
30x48
3
0
x
4
8DW
30x4830x4830x4830x4830"24" CLR MIN18" CLR42" CLR
44" CLR18" CLR
16' - 11"
5' - 5"11' - 6"25' - 7"W/D30x48
To Patio
BATHROOM
KITCHEN
LIVING ROOMDW
30x4830x4830x4830x4830"16' - 11"6' - 6"11' - 11"28' - 7"10' - 2"BATHROOM
BEDROOM
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3:
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
UNIT PLANS - 1BR-A, 1BR-B, 1BR-C
A401A401Lion's Gate Multi-family Development
800 SF
1/4" = 1'-0"A401
1 UNIT 1BR-A-GF
1/4" = 1'-0"A401
3UNIT 1BR-B MEZZ LEVEL 1
1/4" = 1'-0"A401
4UNIT 1BR-B MEZZ LEVEL 2
1/4" = 1'-0"A401
2 UNIT 1BR-B
1/4" = 1'-0"A401
5UNIT 1BR-B-GF
1/4" = 1'-0"A401
6UNIT 1BR-C Level 1
1/4" = 1'-0"A401
7UNIT 1BR-C Level 2
01-19-2024
W&D
W&D
W&DW&D
W&DW&DDWBB
BB24' - 0"23' - 10 1/2"
10' - 11 1/4"12' - 11 1/4"
To Balcony
44" CLR18" CLR 7' - 9"4' - 9"11' - 6"18" CLR
42" CLR24" CLR MIN
30x48
3
0
x
4
8
0' - 1 5/8"3' - 1 1/4"
4' - 0 1/2"
6' - 5 3/8"
5' - 0 1/2"DWBB
BB
23' - 11"8' - 9"7' - 2 1/2"15' - 0"11' - 3"12' - 8"16' - 2"14' - 9 1/2"30' - 11 1/2"To Patio
lLIVING ROOM
KITCHEN
BEDROOM
BATHROOM
44" CLR18" CLR
24' - 0"22' - 10"DWBB
BB
13' - 0"11' - 0"7' - 8"4' - 10"10' - 4"To Patio
BEDROOM
BATHROOM
KITCHEN
LIVING ROOM
44" CLR18" CLR30x4830x48
31' - 8 1/2"20' - 3"17' - 1"6' - 8 3/8"10' - 7"3' - 5"17' - 8 1/2"
To Patio (GF) /
To Balcony (Upper floors)
BEDROOM
BATHROOM
KITCHEN
LIVING ROOM
DW44" CLR18" CLR24' - 0"23' - 0"
10' - 6"12' - 6"
18" CLR
42" CLR24" CLR MIN
30x48
3
0
x
4
8 7' - 9"4' - 9"11' - 6"DWBB
BB60"18" CLR
18" CLR42" CLR30x4830x48DW27' - 2 1/2"10' - 4"17' - 1"10' - 3"21' - 5 1/2"7' - 7"To Patio
LIVING ROOM
KITCHEN
BATHROOM
BEDROOM
44" CLR18" CLR
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3:
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
UNIT PLANTS - 1BR-D, 1BR-E
A402A402Lion's Gate Multi-family Development
1/4" = 1'-0"A402
1 UNIT 1BR-D1
1/4" = 1'-0"A402
2 UNIT 1BR-D2
1/4" = 1'-0"A402
3UNIT 1BR-D3
1/4" = 1'-0"A402
5UNIT 1BR-E
1/4" = 1'-0"A402
4UNIT 1BR-D4
1/4" = 1'-0"A402
6UNIT 1BR-E2
01-19-2024
W&D
UP
W&DDW
BB
BB
30' - 4"24' - 0"To Balcony
LIVING ROOM BEDROOM
BATHROOM
KITCHEN
44" CLR18" CLR
30x48
30x4830' - 4"
DW
BB
BB4' - 0"24' - 0"To Balcony
LIVING ROOM
KITCHEN
BATHROOM
BEDROOM
24" CLR MIN
30x48
30x4842" CLR
18" CLR44" CLR18" CLR
11' - 5 1/8"
30' - 4"
OPEN TO BELOW
18' - 4"10' - 11"5' - 8"15' - 7"14' - 9"24' - 0"ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3:
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
UNIT PLANS - 1BR-F
A403A403Lion's Gate Multi-family Development
1/4" = 1'-0"A403
1 UNIT 1 BR-F
1/4" = 1'-0"A403
2UNIT 1BR-F W/ Mezz
1/4" = 1'-0"A403
3UNIT 1BR-F W/ MEZZ upper
01-19-2024
W/DW/DW/DW/DW/D22' - 10"44" CLR18" CLR
18" CLR
42" CLR18" CLR 42" CLR18" CLR42" CLR42" CLR18" CLR24" CLR MIN
42' - 0"
3' - 7"5' - 0"11' - 3"11' - 7"10' - 7"15' - 10"5' - 1"8' - 4"24" CLR MIN10' - 0"8' - 3"2' - 7"30x48
30x48
To Balcony
W/D2' - 8"DWBB30x48
BB
30x4830x48
30
x
4
8
30x482' - 6"
KITCHENBATHROOM BATHROOM
BEDROOM
BEDROOM
LIVING ROOM 7' - 2 1/2"To Balcony
30x48
3
0
x
4
8
11' - 2"
KITCHEN
MASTER BATHROOM
MASTER BEDROOMBEDROOM
BATHROOM
LIVING ROOM
30"DW30x4830x4830x4830x48
11' - 2"16' - 9"11' - 5"24' - 0"18" CLR
42" CLR18" CLR
42" CLR18" CLR42" CLR44" CLR18" CLR
39' - 4"
24" CLR MIN11' - 3"5' - 0"7' - 9"24" CLR MIN18" CLR42" CLR
2' - 6"
11' - 5"8' - 2"5' - 1"3' - 6"11' - 2"11' - 6"4' - 8"7' - 10"To Patio
30x4830
x
4
8
5' - 4 1/2"3' - 6"11' - 2"
BATHROOM
BEDROOM
KITCHEN
LIVING ROOM
BATHROOM
BEDROOM
30"DW30x4830x4830x4830x4824' - 0"18" CLR
42" CLR18" CLR
42" CLR18" CLR42" CLR44" CLR18" CLR
39' - 4"
24" CLR MIN11' - 3"5' - 0"7' - 9"24" CLR MIN18" CLR42" CLR
2' - 6"
11' - 5"8' - 2"5' - 1"3' - 6"11' - 2"11' - 6"4' - 8"7' - 10"18" CLR
18" CLR42" CLR42" CLR44" CLR18" CLR 42" CLR18" CLR24" CLR MIN24" CLR MIN
18" CLR
42" CLRTo Patio
24" CLR MIN
30"
DW
30x4830x48
30x48
30x48
30x48
2' - 6"21' - 0 1/2"8' - 10"8' - 10"11' - 5"10' - 9"8' - 4"6' - 6"14' - 11"10' - 5"9' - 9"5' - 2"16' - 8"
42' - 0"
BEDROOM MASTER BEDROOM
MASTER BATHROOMKITCHENBATHROOM
LIVING ROOM
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3:
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
UNIT PLANS - 2BR-A, 2BR-B
A404A404Lion's Gate Multi-family Development
800 SF
1/4" = 1'-0"A404
1 UNIT 2BR-A
1/4" = 1'-0"A404
3UNIT 2BR-B
1/4" = 1'-0"A404
4UNIT 2BR-B-GF
1/4" = 1'-0"A404
2 UNIT 2BR-A2
01-19-2024
W/DUP
DN
W/DDW44" CLR
18" CLR18" CLR42" CLR
18" CLR
42" CLR18" CLR42" CLR42" CLR18" CLR
24" CLR MIN24" CLR MIN5' - 6"9' - 9"12' - 0"13' - 9"27' - 0"11' - 9"21' - 3"10' - 3"30x4837' - 4"
5' - 10"
30x4830"30x48
30x4830x4811' - 7"
To Balcony
BATHROOM
BEDROOM
LIVING ROOM
KITCHEN
BATHROOM
BEDROOM
8' - 1"18" CLR
42" CLR18" CLR42" CLR
30"DW30x4830x4830x4830x48
24" CLR MIN
30x48
3
0
x
4
8
42" CLR
18" CLR15' - 11"39' - 4"24' - 0"7' - 9"5' - 0"11' - 3"11' - 0"3' - 7"5' - 2"8' - 2"11' - 5"
42" CLR
18" CLRTo Balcony
42" CLR18" CLR
44" CLR18" CLR 4' - 0" BATHROOM
BEDROOM
KITCHEN
LIVING ROOM
BEDROOM
BATHROOM 17' - 6"OPEN TO BELOW
14' - 2"DWLIVING ROOM
10' - 6 1/2"6' - 6"24' - 0"31' - 0"18" CLR42" CLR18" CLR
42" CLR44" CLR18" CLR18" CLR42" CLR
39' - 4"
To Patio
DW30x4830"
18" CLR
42" CLR24" CLR MIN
18" CLR
42" CLR24" CLR MIN
30x4830x4830x48
30x48
3
0
x
4
86' - 5"16' - 11"7' - 8"16' - 1"7' - 1"7' - 10"11' - 2"17' - 1"11' - 1"
11' - 2"3' - 6"5' - 5"8' - 4"10' - 11"
BEDROOM
BATHROOM
LIVING ROOM
K,ITCHEN
MASTER BEDROOM
MASTER BATHROOM
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3:
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
UNIT PLANS - 2BR-B, 2BR-C
A405A405Lion's Gate Multi-family Development
800 SF
1/4" = 1'-0"A405
4UNIT 2BR-C
1/4" = 1'-0"A405
1 UNIT 2BR-B Mezz level 1
1/4" = 1'-0"A405
2 UNIT 2BR-B MEZZ LEVEL 2
1/4" = 1'-0"A405
3UNIT 2BR-B2
01-19-2024
W/DW/DW/D
W/D W/D18" CLR42" CLR
44" CLR18" CLR 24" CLR MIN3' - 7"5' - 1"7' - 8"9' - 10"2' - 6"11' - 8"30x4830x
4
8DW30x4830x4830x4830x4830"16' - 4"24' - 0"To Balcony
BATHROOM
BEDROOM
LIVING ROOM
KITCHEN
16' - 11"28' - 7"44" CLR18" CLR 18" CLR42" CLR
24" CLR MIN7' - 9"3' - 7 1/2"5' - 6 1/2"10' - 2"4' - 4"14' - 1"To Balcony
30x4830x48
BEDROOM
LIVING ROOM
KITCHEN
BATHROOMDW30x4830x4830x4830x4830"16' - 11"18" CLR42" CLR
24" CLR MIN25' - 7"44" CLR18" CLR
8' - 8"8' - 3"10' - 3"30x4830
x
4
8 15' - 4"BEDROOMLIVING ROOM
KITCHEN
BATHROOMDW
30x4830x4830x4830x4830"To Patio
28' - 7"44" CLR18" CLR7' - 11"9' - 0"30x48
30x48To Balcony16' - 11"15' - 10"2' - 4"10' - 5"
24" CLR MIN
18" CLR
42" CLRDW
30x4830x48
30x4830x48
30"
BATHROOM
KITCHEN
BEDROOM
LIVING ROOM 33' - 6"16' - 4"18" CLR42" CLR
24" CLR MIN30x4830x
4
8
44" CLR18" CLRDW30x48 30x4830x4830x4830"To Balcony
BEDROOM
KITCHEN
BATHROOM
LIVING ROOM
21' - 2"2' - 6"9' - 10"ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3:
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
UNIT PLANS - ST-A, ST-B, ST-C, ST-D
A406A406Lion's Gate Multi-family Development
800 SF
1/4" = 1'-0"A406
1 UNIT ST-A
1/4" = 1'-0"A406
3UNIT ST-B
1/4" = 1'-0"A406
4UNIT ST-C
1/4" = 1'-0"A406
5UNIT ST-D
1/4" = 1'-0"A406
2 UNIT ST-A2
01-19-2024
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
3D RENDERING
A501A501Lion's Gate Multi-family Development 3D RENDERING
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
3D RENDERING
A502A502Lion's Gate Multi-family Development 3D RENDERING
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
3D RENDERING
A503A503Lion's Gate Multi-family Development 3D RENDERING
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. DESIGN ARC LOS ANGELES ©
FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA
2558 OVERLAND AVE.
LOS ANGELES
CA 90064
P: 310 204 8950
Project Address
FOOTHILL BLVD.,
RANCHO CUCAMONGA
CALIFORNIA, 91730
Project Name
Lion's Gate
Legal Description
APN: 0208-632-47-0000
See Sheet G002
Original Date: 02-13-2023
Revision 1: 07-05-2023
Revision 2: 10-25-2023
Revision 3: 01-19-2024
Revision 4:
Revision 5:
Revision 6:
Sheet of sheets
Revision 7:
Revision 8:
Revision 9:
Revision 10:
Sheet Title:
3D RENDERING
A504A504Lion's Gate Multi-family Development 3D RENDERING
CMU SITE WALL PLASTER
CMU-1 CMU Site Wall: Refer to Landscape sheet L-05 for CMU Specifications PL-1 Exterior plaster PL-1 Exterior plaster PL-1 Exterior plaster
P-1 Snowbound - SW 7004 P-2 Passive - SW 7064 P-4 Cityscape - SW 7067
SIDING
MT-1 Perforated metal guardrail, paintedM-1 6" Horizontal cementitious siding, painted or integral
P-3 Gray Matters - SW 7066
M-2 Steel or aluminum carports such as Baja Carports or similar , painted
P-2 Passive - SW 7064 P-5 Peppercorn - SW 7674 TYP. RECESSED WINDOW
DOORS, WINDOWS, & FRAMES
DW-1 Milgard vinyl windows or equal, silver finish DW-2 Milgard vinyl sliding doors or equal, silver finish DW-3 Clear anodized aluminum storefront system DW-4 Aluminum garage door, painted or integral
P-5 Peppercorn - SW 7674
Lion's Gate Multi-family Development A601FOOTHILL BLVD., RANCHO CUCAMONGA, CALIFORNIA, 91730
DesignARC LA Sheet of sheets Revision 10: 2558 OVERLAND AVE. Sheet Title: MATERIAL BOARD / Revision 9: LOS ANGELES DETAILS Revision 8: CA 90064
P: 310 204 8950 Revision 7:
Project Address Revision 6:
FOOTHILL BLVD., Revision 5:
RANCHO CUCAMONGA Revision 4:
CALIFORNIA, 91730 Revision 3: 01-19-2024
Project Name Revision 2: 10-25-2023
Lion's Gate Revision 1: 07-05-2023
Legal Description Original Date: 02-13-2023
APN: 0208-632-47-0000
See Sheet G002
ARCHITECTURE + INTERIORS
ALL DESIGN IDEAS AND PLANS INDICATED OR REPRESENTED BY THESE
DRAWINGS ARE OWNED BY AND ARE THE PROPERTY OF DESIGNARC AND
WERE CREATED AND DEVELOPED FOR USE IN CONNECTION WITH THE
SPECIFIED PROJECT. NONE OF SUCH IDEAS, DESIGNS, OR PLANS SHALL BE
USED FOR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION
OF DESIGNARC LOS ANGELES. © DESIGN ARC LOS ANGELES
MATERIAL BOARD
SELECTED BUILDING MATERIALS
MISCELLANEOUS METALS
DRB 05-02-2024
DOORS, WINDOWS, & FRAMES
DESIGN REVIEW COMMENTS
May 7, 2024
7:00 p.m.
Sean McPherson, Principal Planner
DESIGN REVIEW – LONE OAK-RANCHO, LLC– A request to redevelop and expand an existing
beverage distribution facility over two phases to include production, bottling and distribution
operations on approximately 30.11 acres of land generally bounded by Haven Avenue to the west,
7th Street to the north, Utica Avenue to the east, and 6th Street to the south in the Mixed
Employment 2 (ME2) Zone. APN: 0209-411-002, -003, 004, -023, -24, -32, -34, -35. (DRC2023-
00067).
Site Characteristics:
The 30.11-acre project site currently comprises 8 parcels of land which are roughly bounded by
Haven Avenue to the west, 7th Street to the north, Utica Avenue to the east, and 6th Street to the
south. The project does not include the parcel at the southwest corner of Haven Avenue and 7th
Street (APN: 0209-41-101).
The project area is currently improved with 4 existing buildings which total approximately 208,575
square feet. This includes two office buildings located near the northeast corner of Haven Avenue
and 6th Street (9227 Haven Avenue and 9267 Haven Avenue), the existing beverage distribution
warehouse facility near the northwest corner of Utica Avenue and 6th Street (10670 6th Street),
and an existing industrial building near the southwest corner of Utica Avenue and 7th Street (10655
7th Street). Other existing improvements include parking areas, truck loading areas, drive aisles
and existing landscaping. The project area is otherwise vacant and covered in native and non-
native shrubs and grasses.
Figure 1: Vicinity/Aerial Photograph
DRC COMMENTS
DR DRC2022-00067– LONE OAK- RANCHO LLC
May 7, 2024
Page 2
Background and Context:
In addition to the project being located in the Mixed Employment 2 (ME2) zone, the General Plan
land use designation of the subject project area is 21st Century Employment District. As stated in
the General Plan, development within the 21st Century Employment District is “…urban in
character where buildings are expected to be set near or at the sidewalk and oriented toward the
primary street to provide spatial definition of the public realm and ground floor activity. Parking
structures are consistent in architectural design with adjacent buildings… (and) streetscapes
provide safe and comfortable environments for bicyclists and pedestrians with continuous
sidewalks, shade trees and native landscaping.” (General Plan, Volume 2, Page 87). In short, the
21st Century Employment District land use designation effectuates the City Council’s long-term
vision of transforming Haven Avenue into the City’s central north-south artery.
The land use, general plan, and zoning designations for the project site and adjacent properties
are as follows:
Table 1: Surrounding Land Use and Zoning Context
Project Design and Layout:
As noted, the applicant proposes to expand the existing beverage distribution facility to include
production, bottling and distribution operations over two phases. Phase 1 includes the demolition
of approximately 208,575 square feet of building area, which includes the demolition of the
northerly office building located near the northeast corner of Haven Avenue and 6th Street (9227
Haven Avenue) and the existing distribution warehouse located near the northeast corner of Utica
Avenue and 6th Street (10670 6th Street), in addition to the demolition of associated improvements
such as parking lots and landscaping. Notably, the southerly of the two office buildings located
near the corner of Haven Avenue and 6th Street (9267 Haven Avenue) will remain.
Land Use General Plan Zoning
Site
Existing office, warehouse,
distribution, industrial and
vacant
21st Century
Employment District
Mixed-Employment 2
(ME2)
North Office/Industrial 21st Century
Employment District
Mixed-Employment 2
(ME2)
South Hotel/Industrial 21st Century
Employment District
Mixed-Employment 2
(ME2)
East Office/Commercial/Industrial 21st Century
Employment District
Mixed-Employment 2
(ME2)
West Office/Commercial 21st Century
Employment District
Mixed-Employment 2
(ME2)
*Zoning designation in place at the time that the applicant submitted their SB 330 application
DRC COMMENTS
DR DRC2022-00067– LONE OAK- RANCHO LLC
May 7, 2024
Page 3
Figure 2: Phase 1 Demolition Exhibit
In addition to demolition of existing structures, Phase 1 also includes the construction of
approximately 959,441 square feet of new building area which includes the construction of a new
beverage Production Center (PC), Distribution Center (DC), an Automated Storage and Retrieval
System (ASRS), a truck deck, and associated infrastructure improvements including a
cogeneration facility used in the processing of beverages and other improvements such as
parking areas, truck loading and parking areas, landscaping, and fences and walls. The PC, DC,
and ASRS components will be located in one large building which will be located largely at the
south-central portion of the project area. A 4-story parking structure is also proposed to be
constructed at the southerly end of the project adjacent to 6th Street. In addition, the existing office
building at 9267 Haven Avenue will remain and is proposed to be renovated and function as
additional office space for the project user. Lastly, Phase 1 also includes the construction of a
ground water supply well to be located at the northwest corner of Utica Avenue and 6th Street.
Currently, the applicant proposes to enclose this water infrastructure with a wrought-iron fence
which will make this infrastructure visible from the street and public right of way.
Staff notes that Phase 2 as currently proposed by the applicant is still in development and that no
renderings or architectural details have been provided for review for this second phase. Staff
notes that once this level detail is provided, additional entitlements may be required, which could
necessitate Design Review Committee review.
DRC COMMENTS
DR DRC2022-00067– LONE OAK- RANCHO LLC
May 7, 2024
Page 4
Figure 3: Proposed Site Plan
Architecture:
The applicant proposes a variety of building materials throughout the site. Specifically, the large
PC/DC/ASRS building, which is the dominant feature of the project, will provide a façade on all
elevations comprised of insulated metal paneling of various colors ranging from grey to red. The
north and west elevations of the PC/DC/ASRS building will include tilt-up concrete construction in
addition to metal panel elements. The east elevation of the PC/DC/ASRS will include these same
elements, in addition to metal structural components to support a raised truck deck and ramp.
Other street-facing facades throughout the project, such as the parking structure, combines
insulated metal panels with metal mesh intended to screen the structure and provide design
consistency throughout. Where office facades exist, both internal and external to the site, these
comprise metal and stucco elements, in addition to glazing and window surrounds comprised of
metal paneling.
DRC COMMENTS
DR DRC2022-00067– LONE OAK- RANCHO LLC
May 7, 2024
Page 5
Figure 4: East elevation (note elevated truck deck and ramp)
Figure 5: West elevation of project
Figure 6: North elevation of project
Figure 7: South elevation of project.
As the project has been reviewed by staff, a primary focus of architectural treatment has been the
Haven Avenue façade of the PC/DC/ASRS building (west elevation). The Haven Avenue
elevation of this building consists primarily of concrete tilt-up construction with several enhanced
features. To meet the General Plan’s expectation that buildings within the 21st Century
Employment District be closer to the street and provide ground floor transparency, while also
trying to maintain internal security for the user, the applicant proposes opaque spandrel glass,
exaggerated window surrounds made of metal paneling, and multiple vertical elements comprised
of dark metal paneling. The window surrounds and vertical features protrude from the painted
concrete tilt-wall to provide depth, and at one point along the facade includes double-high opaque
DRC COMMENTS
DR DRC2022-00067– LONE OAK- RANCHO LLC
May 7, 2024
Page 6
spandrel glass window features so as to provide the appearance of a two-story façade. The
remainder to the PC/DC/ASRS building along Haven Avenue is comprised of painted concrete
tilt-up walls and a band of vertical metal panels which protrude from the concrete tilt-wall façade
(see Figure 8 below).
Figure 8: Detail of Haven Avenue elevation of the PC/DC/ASRS building.
In addition to establishing criteria for creating places with urban character, the 21st Century
Employment District land use designation and Mixed Employment 2 (ME2) zone also calls for
significant frontage improvements to improve the pedestrian realm, particularly as Haven Avenue
is identified as a “Boulevard” pursuant to the General Plan (Volume 2, Page 162). In response to
this requirement, the applicant has provided a multi-modal frontage lane along the project’s Haven
Avenue frontage to accommodate both vehicles and bicycles. This frontage lane has been
designed to also accommodate a future Bus Rapid Transit (BRT) stop at Haven Avenue and 6th
Street. In addition, the applicant has also provided linear sidewalks approximately 10 feet wide
along the Haven Avenue frontage with evenly spaced shade trees which has been designed in
accordance with General Plan provisions for the 21st Century Employment District land use
designation. Sidewalks along the secondary frontages are 6 feet in width.
Along 6th Street, the applicant proposes 6-foot sidewalks, consistent with the General Plan
Placemaking Toolkit (General Plan, Volume 4, Page 323). In addition, two enhanced paving areas
are provided with seat walls to improve the pedestrian experience. Lastly, along the 6th Street
frontage, the applicant has included a Class IV cycle track. The 7th Street and Utica Avenue street
frontages also include 6-foot wide sidewalks with landscaped trees, consistent with the General
Plan.
Figure 9: 6th Street frontage showing enhanced paving with seat walls.
DRC COMMENTS
DR DRC2022-00067– LONE OAK- RANCHO LLC
May 7, 2024
Page 7
Compliance with Development Standards:
The applicant has applied for a master plan to establish site specific development standards.
Pursuant to the Development Code, a master plan is a legislative action which requires a
recommendation by the Planning Commission and approval by the City Council.
Please see the reference table below regarding the project’s compliance with relevant
development standards:
Table 2: Development Standards Compliance Table
Development Standard Required Proposed Complies
Floor Area Ratio 0.4 to 2.0 .89 YES
Setback – Haven Avenue 5 to 15’ (min/max) Var. 25.8’ to 39.8’ YES*
Setback – Utica Avenue
5 to 15’ Var. 97’ to 110’ YES*
Setback – 7th Street 5 to 15’ Approx. 14 feet YES
Setback – 6th Street 5 to 15’ Var. approx.. 16’ to
78.5’ YES*
Building Height 132 feet (for High-Rise
Building Type) 131 feet YES
*Complies upon approval of the master plan
Staff Recommendation:
Relative to the architectural treatments along the Haven Avenue façade of the PC/DC/ASRS
building, staff has identified additional features which, if added, could further achieve compliance
with the expectations of the general plan and the requirements of the development code.
Specifically, the applicant must clarify the window height of proposed windows along Haven
Avenue at the west elevation of the PC/DC/ASRS. The development code requires that windows
be 12-20 feet in height. The applicant has not clearly identified this height. Also, pursuant to
Development Code 17.132, the applicant must determine the appropriate “building frontage type”
used along this building facade. Notably, it appears the applicant has identified this building type
as “High-Rise.” In previous conversations with the applicant, staff has suggested that the applicant
consider “shopfront” building frontage. Thus, staff specifically recommends that west elevation
along Haven Avenue of the PC/DC/ASRS building be modified to include projections above
windows, such as metal awnings pursuant to applicable requirements of the shopfront frontage
type.
Staff also recommends that the proposed landscaped adjacent to the linear sidewalk on Haven
Avenue be reduced and replaced with additional enhanced paving at select areas, similar to the
enhanced paving treatment proposed along 6th Street. Incorporating enhanced paving may permit
the inclusion of benches and seating areas which would improve the intended urban aesthetic of
the project’s frontage along Haven Avenue.
DRC COMMENTS
DR DRC2022-00067– LONE OAK- RANCHO LLC
May 7, 2024
Page 8
Lastly, staff recommends that the Design Review Committee consider recommending screening
for the proposed ground water supply well. Options may include decorative screening at the
perimeter of the site at the corner of Utica Avenue and 6th Street, the construction of a “pump
house” building which could enclose the proposed infrastructure or another alternative as the
Committee may recommend.
☐Recommend Approval of the design of the project as proposed by the applicant.
OR
☒Recommend Approval with Modifications to the design of the project by incorporating
revisions requested by the Committee. Follow-up review by the Committee is not required. The
revisions shall be verified by staff prior to review and action by the Planning Director / Planning
Commission.
☐Recommend Denial of the design of the project as proposed by the applicant.
Design Review Committee Action:
Staff Planner: Sean McPherson, Principal Planner
Members Present:
Staff Coordinator: Jennifer Nakamura, Deputy Planning Director
Exhibit A – Architecture Plans
EXHIBIT A
Due to file size, this attachment can be accessed through the following link:
Architecture Plans