Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAbout2005/06/08 - Agenda Packet
n
-J
•
THE CITY OF RANCHO CUCAMONGA
PLANNING COMMISSION
AGENDA
CR~tiNCn June 8, 2005 - 7:00 PM
Rancho Cucamonga Civic Center
Council Chambers
10500 Civic Center Drive
Rancho Cucamonga, California
I. CALL TO ORDER
Pledge of Allegiance
Roll Call
Chairman Macias _ Vice Chairman McNiel _
Fletcher _ McPhail _ Stewart _
II. ANNOUNCEMENTS
III. APPROVAL OF MINi1TES
May 25, 2005
IV. CONSENT CALENDAR
The following Consent Calendaritems are expected to be routine and non-controversial
They wdl be acted on by the Commission at one time without discussion Ifanyone has
concern over any item, it should be removed for discussion
A. HILLSIDE DESIGN REVIEW DRC2005-00003 - AGUIRRE/BRUNO. A
proposal to construct atwo-story single-family residence with a floor area
of 3,974 square feet (including the garage, patios, and decks) on a parcel
of about 12,000 square feet in the Low Residential Distract, (2-4 dwelling
units per acre), located west of Predera Court at the north side of Camino
Predera - APN• 0207-631-22 This protect is categorically exempt from
the requirements of the California Environmental Quality Act (CEQA)
pursuant to State CEQA Gwdelmes Section 15303(a) (Class 3 Exemption -
New Construction or Conversion of Small Structures).
PLANNING COMMISSION AGENDA
June 8, 2005
CUI CONGA 'Z
V. PUBLIC COMII~NT5
This is the hme and place for the general public to address the commission. Items to be
discussed here are those that do not already appear on this agenda
VI. COMIVIISSION BUSINESS
VII. ADJOURNMENT
The Planning Commission has adopted Administratroe Regulations that set an 11 00 p m
ad/ournment time If items go beyond that hme, they shall be heard only wdh the consent
of the Commission
THE PLANNING COMMISSION WILL ADJOURN TO A WORKSHOP
IMMEDIATELY FOLLOWING TO DISCUSS DRC2005-00448 - ETCO
DEVELOPMENT AND DRC2005-00273 - SHEA HOMES
1, Gatl Sanchez, Planning Commission Secretary of the Cify of Rancho Cucamonga, or
my designee, hereby certdy that a true, accurate copy of the foregoing agenda was
posted on June 2, at least 72 hours poor to the meeting per Government Code Section
m
ong
a
54964 2 at 10500 Civic Censer Dnve, Rancho Cuca
Q
~
/
~
~.!/o-l ~Cllcs.c.~i
If you need special assistance or accommodations to participate in this meeting,
please contact the Planning Division at (909) 477-2751) Notification of 48 hours
pnor to the meeting will enable the City to make reasonable arrangements to
ensure accessibility Listening devices are available for the heanng impaired
•
•
Vicinity Map
Planning Commission
Agenda June 8, 2005
•
A~
Q
City of Rancho Cucamonga "
RANCUO CUCAMONGA
Staff Report
DATE: June 8, 2005
TO: Chairman and Members of the Planning Commission
FROM: Brad Buller, City Planner
BY: Mike Smith, Assistant Planner
SUBJECT• HILLSIDE DESIGN REVIEW DRC2005-00003 - AGUIRRE/BRUNO - A proposal to
construct a two-story single-family residence with a floor area of 3,974 square feet
(including the garage, patios, and decks) on a parcel of about 12,000 square feet in the
Low Residential District (2-4 dwelling units per acre) located west of Predera Court on the
north side of Camino Predera - APN. 0207-631-22 This project is categorically exempt
from the requirements of the California Environmental Quality Act (CEQA) pursuant to
State CEQA Guidelines Section 15303(a) (Class 3 Exemption -New Construction or
Conversion of Small Structures)
BACKGROUND: The proposed single-family residence is located in the Hillside Overlay District
Development proposed in the Hillside Overlay is subject to the Hillside Development Regulations,
Section 17 24 of the Development Code. The intent of these regulations is to minimize grading and
ensure that the form, mass, profile, and architectural features of the house are designed to blend with the
natural terrain, preserve the character and profile of the slope, and groe consideration to the lot size and
configuration. The protect includes excavation equal to, or exceeding 5 feet in vertical depth, therefore,
the application regwres the review and approval by the Planning Commission
ANALYSIS:
A. General• The protect site is located on the north side of Camino Predera on a parcel of about
12,000 square feet The parcel to the north is developed with asingle-family residence; the
property to the south is vacant, the properties to the east and west are vacant, but were recently
approved for development (Hillside Design Review DRC2004-00375 and DRC2004-00630,
respectively). The topography slopes in a generally northwest to southeast direction The existing
topography has two distinct slope profiles At the front of the property, the slope is generally 40
percent (between 2.1 and 3 1) At the front property Ime, the existing elevation is about 1,304 feet
and rises to about 1,317 feet at a point about 25 feet north, or behind, the front property Ime From
there, the slope is about 15 percent to the rear property line, which is at a general elevation of
about 1,335 feet
The applicant is proposing to construct atwo-story single-family residence with an attached 2-car
garage The first floor of the house, not including the garage, will have two stepped pads with
finished floor elevations of 1,329 5 feet and 1,326 5 feet The garage will have a finished surface
elevation of 1,322.5 feet The stepping will be consistent with the existing contours and direction of
slope The depth of excavation, or cut, that will be required to construct the driveway and a small
Item A
PLANNING COMMISSION STAFF REPORT
DRC2005-00003 - AGUIRRE/BRUNO
June 8, 2005
Page 2
portion of the yard area at the northwest comer of the house will exceed 5 feet (Exhibit E). The
house will screen the depth of cut at the northwest portion of the property However, excavation for
the driveway will be visible from Camino Predera The applicant proposes a serves of terraced
3-foot high retaining walls, separated by 3 feet, along the south side of the property adjacent to the
driveway. These walls, in contunction with appropriate landscaping, will reduce the apparent depth
of cut (note that although the Grading Plan indicates an overall height of each wall at 4 feet, the
exposed height will be 3 feet) Excavation throughout the rest of the property, including the building
pads, will be less than 5 feet The house will have setbacks from the side property lines on the
east and west of 16 5 feet and 7 feet, respectively. Furthermore, the house will have front and rear
yard setbacks of 58 feet (to the garage) and 30 feet, respectively. The setbacks of the proposed
structure exceed the minimum standards established for this development district and, as a result,
the visual bulk of the house will be minimized. The overall height of the structure will not exceed 30
feet measured from the finished grade Lot coverage will be about 23.5 percent; the maximum
permissible in the Low Residential District is 40 percent.
B. Neighborhood Meeting On August 24, 2005, a meeting was conducted to gather input and
comments from the owners of the surrounding properties on Camino Predera and immediately to
the north on Red Hill Country Club Drive (Exhibit H) The primary concern stated by those present
was the potential loss of views caused by new construction on currently vacant land along Camino
Predera, speafically on the south side of the street As the applicant's property is on the north side
of the street, and is significantly lower than the house to the north, his design and grading will allow
the house to have a lower profile Any loss of views will be minimal
C. Grading and Design Review: Both the Grading and Design Review Committees recommended
approval of the project at their meetings on May 17, 2005 (Exhibit I). The applicant, at the request
of the Design Review Committee, has included additional trim beneath several windows and, where
practical, continued the dark colored, stucco finished band along the base of the house to all
elevations of the home (Exhibit F)
D Environmental Review The project is categorically exempt from the requirements of the California
Environmental Quality Act pursuant to Section 15303(a) of the State CEQA Guidelines.
RECOMMENDATION: Staff recommends approval through the adoption of the attached Resolution and
Standard Conditions
Respectfull submitted,
Bra u r /
City Planner
Attachments• Exhibit A - Information Sheet -Hillside Design Review
Exhibit B - Project Site Map
Exhibit C - Site Plan
Exhibit D -
Exhibit E - Grading Plan with Sections
Grading Plan Identifying Where Excavation Exceeds 5 feet
Exhibit F - Elevations
Exhibit G - Floor Plan
Exhibit H - Neighborhood Meeting Notification Area Map
Exhibit 1 - Design Review Committee Action Agenda dated May 17, 2005
Draft Resolution of Approval for Hillside Design Review DRC2005-00003
x} -c~-
INFORMATION SHEET
HILLSIDE DESIGN REVIEW
•~
FILE NO: Hillside Design Rewew DRC2005-00003
PROJECT NAME. Single-family residence
APPLICANT: Sam/Pam Agwrre and Sarah Bruno
LOCATION: Lot 32, Camino Predere; APN: 0207-631-22
FLOOR AREA OF BUILDING: 4,722 square feet (2 stories, including the porch and 2-
cargarage)
LOT COVERAGE: 3,974 square feet (23 5%) including roof overhangs
LOT SIZE: 12,203 square feet
LAND USE CLASSIFICATION: Residential
EXISTING ZONING: Low (L) Residential (2-4 dwelling units per acre)
EXISTING LAND USE: Vacant
GENERAL PLAN DESIGNATION: Residential
ADJACENT ZONING/LAND USE:
ZONING LAND USE
North: Low (L) Residential (2-4 du/acre) single-family residences
South: Low (L) Residential (2-4 du/acre) vacant
East• Low (L) Residential (2-4 du/acre) vacant, single-family residence recently
approved (Related file DRC2004-00375)
West: Low (L) Residential (2-4 du/acre) vacant; single-family residence recently
approved (Related file• DRC2004-00630)
EXHIBIT A ~ 3
.,
-.
:,
ALTA
LOYA
'•
Y ,• x
y ~,f~ ~ 5
r~
1, ~~: ..W......~
PROJECT SITE
Nrd
Hdl
Cuunh~
CIW
ONTA~~ilO
R
~ti
;~
11®R
~OiF
ae ~
iv
EXHIBIT B ~ ~ ~`" I ! 1 A
y g
x
~ _ ...~~ Im ~.,~....o «.~. .1
Q
4 ...w~.. oxnw ~~ ]ON3a53a $ 7 tL -1
!e F Pa~pE ( 61. °
~
"°
"
~° 3YtllIlOY and a vMYS Atl015-oMl 9
9
A
~
c
~ i
F Ea la~ ~~
~ e7e ~
,wo +~r.~ s
1 ~~
[[(
;~
e2e
~1 I 1 ~l
l l I
ll ll l
l l 1
`l
- i
~~
'
~ ~ f ' -r~=-j~.
~ ~ I
1 ~~ ~
~~ ti~ I
o
~ ~ ~ ~~ ~ ;
~ I i
1
1 J
\ Y I I I~ ^]
~ 11 11
I
i L
~.I
w
1 i
1 1 u
F
~ ~ 1 j
~ l I d1
~
~ ,
~
I
1 • -
-
.
~ I ' !
'\-h',--''ill i
_....
.. ` 1_
_ -
~ i
i .wYr~i ~ ~
+~1
l l 11
_ wai Q
Ell
~ ~l
f 1 l
l 1 1
I 1
~
~kk
>~ 1 1 11
1 1
®
ra y
yyy
7
i
®
;
(~ Q
I (~~/
I
E i
I I
v -
a -
-~
- ~e-V ~ ~ ___~
-- ----- ---- ---- --0-0 i
~ t~
~~
o-- -
i ------- ,
S 5 ~
~ i
a
~
~
~ - --
o- ~~ ~
~
-------
*~
i
~
~
-
Q
4
~
i
~ ~
~~
!l4f
a
~EEg
5
5
~- __ ~
___
~ ~
E
-
g 57i1
~
eaa
9 ... ~
o-~
~ -
- --- - -- --
------ --- -----------
~
S 8 ff
SSSi
~ , i
~ ^
~ b
~ ,l,
b
z~I ~
l9 f
F
fT.? f 1~6
II
I II~
,
III l
I
7
1~
~; fq ~
;
yy
~;
~
~~~~f Eij
i
1sl g
l
i
,EXHIBIT C
r gay
?_'f~°d-dka°
S
x a
i~~~
'" E
~ !
~~ EE ~ g
8 p9
~
€ _ ~
~ ~~
~'~i
~~
~ ~
~~~
~~E ~
E
pp~
4~
y
F
G
~
y
~
gy6.yo
yEy
yE
~
~~
F
8 G9
B ~
O©00®O©00
., ,
oa
o
N q ~
~ G<'
~e~
o
m
ZsUZs
uu G ~
~V ~ ~ ~
~ U
.h ¢ 4 ~~
91, 6
a ~,
IE ~
b
I
h s it
~ e '
l,~ ~
~ I ~
b
e
0
a
~~
XHIBIT D
x
9
~~l~~
aG~6sE A
9 aei
i
4 a
i F - ~ fi
a
f
W ~ ;
ai~y
Sll
F
~~
a
P
~ s % A §
: g
a a a
4 I
p
3 3
~ 4
I a
s a
s 4
I R R
Y ,' a ~ R ~~ R & 9 ~R 9 & ~a S
Q bb m ?y U ~b p bb
I I~• 1~~ ~
I ~
O ~~ ~~
~ ~~
~ ,}y
^~
am
~ ~~ ~
5
W
a ~~
{{
N~T y//`^
y
NT~
Y
I
zT
i
a
s B
a
a
9
4
9
j~~~ c ~ Q
~
Ct~ ~b ~$ g ~.+.~.. O
auaino Nntl6 xruYS wm
r ma a vmns 7aM)a5fa
~
''" 0 ~ ~ ~ ~~)
~ ~
:~ h ~
.....-
O
~
~ ~
'
I ~
4
~ ii
~
i
-va+
L
~ ~
~~
~
h '
~~
i i
I
I
i
~
i
1
8
~
y
1 ~
j I ®
1 ~
i
e ~
i
I
I
I
I ~b
I '
I
~
I i
m
I
•~
.
~
. _ ~
\
.
~
~`,
.~,.~--
•
C~
I`~
~.J
~=~5
~vA~no~
EXH~~~
..~
1320
1315
1310
1305
1300
10 20 30 40 50
SECT{ON E-E
HORIZ. SCALE 1' = 5'
VERT. SCALE 1' = 5'
i
0 20 30 40 50
.x1'~~ ......,....
8g~~tS@pe sg tt "'°""
! I ~ ~i6: YF~4E~~H 'm°
i
~i
i
i
I
i
i
i
I
I
I
I I
i
1
I
1
I
I
I
I
i
~~,~ ~~ ~
3aal~~riid~i 3nms oats-wt Q ~ .. ~
:HIBIT F
C~
z ~ ~ ~
tqq °
~E~gp
~ •~'••~• m o e
oanae m'
axairor ma a 7~umisw i~ 1 ~ ~
'~ 4
f
~
Rd ~ ~~ 9 d ~ ~
9
C
!$'3~ 4
~~,
~.~
L
IBIT G
x ~
9 -av aaniu sn ]tl ~ ~ ' ]I
s
~
Q
x ",
p ...,. ~.. ounne mm wo
wainor ma s vnms 3~~
wou-oMi - 1 3 g Q
Qq
g~~
0~~
~~ C A y G
IA! BS
°~°
® k
~~
- _lJ
(.}_ y3
Nt ~dn~{+{+
Bryn
~~i~
Zit
b
4
Q
N
EXHIB
Foothill Blvd
DESIGN REVIEW COMMENTS
6:50 p.m. Michael Smith May 17, 2005
HILLSIDE DESIGN REVIEW DRC2005-00003 -AGUIRREBRUNO - A proposal to construct a two-
story single-family residence Hnth a floor area of 3,974 square feet (induding the garage, patios, and
ded<s) on a parcel of about 12,000 square feet in the Low Residential District, located west of
Predere Court on the north side of Camino Predera - APN: 0207-631-22.
Backoround: The proposed single-family residence is located in the Low Residential District and is
inducted m the Hillside Overlay District. The intent of the Hillside Development regulations is to
minimize grading and ensure that the form, mass, profile, and architectural features of the house are
designed to blend with the natural terrain, preserve the chareder and profile of the slope, and give
consideration to the lots size and configuration. Typically, Hillside Design Review applications are
reviewed and approved by the City Planner. However, this project requires the review and approval
by the Planning Commission because more than 5 feet of excavation is proposed.
Desion Parameters. The parcels to the north are developed with single-family residences. The
property to the east and west are vacant but are pending development (related file: Hillside Design
Review DRC2004-00375 and DRC2004-00630, respectively). The properties to the south are
vacant. The topography slopes in a generally northwest to southeast direction. The existing
topography has two distinct slope profiles. At the front of the property, the slope is generally 40
percent (between 2:1 and 3:1). At the front property line, the existing elevation is about 1,304 feet
and rises to about 1,317 feet at a point about 25 feet north, or behind, the front property line. From
there the slope is about 15 percent to the rear property line, which is at a general elevation of about
1,335 feet.
The applicant is proposing to construct a two-story single-family residence with an attached 2-car
garage. The first floor of the house, not induding the garage, will have two stepped pads with
finished floor elevations of 1,329.5 feet and 1,326.5 feet. The garage will have a finished surface
elevation of 1,322.5 feet. The "stepping" will be consistent with the existing contours and direction
of slope. The depth of excavation, or "cut," that will be required to construct the driveway and a
small portion of the yard area at the northwest comer of the house will exceed 5 feet (Exhibit "A"and
"B"). The house Hnll screen the depth of cut at the northwest portion of the property. However,
excavation for the dnveway will be visible from Camino Predera. The applicant proposes a series of
terraced 3-foot high retaining walls, separated by 3 feet, along the south side of the property
adjacent to the driveway. These walls, in conjunction with appropriate landscaping, will reduce the
apparent depth of cut (note that although the Grading Plan indicates an overall height of each wall at
4 feet, the exposed height will be 3 feet). Excavation throughout the rest of the property, induding
the budding pads, will be less than 5 feet. The house will have setbacks from the side properly lines
on the east and west of 16.5 feet and 7 feet, respectively. Furthermore, the house will have front
and rear yard setbacks of 58 feet (to the garage) and 30 feet, respectively. The setbacks of the
proposed structure exceed the minimum standards established for this development district and, as
a result, the visual bulk of the house will be minimized. The overall height of the structure will not
exceed 30 feet measured from the finished grade. Lot coverage will be about 23.5 percent; the
maximum permissible m the Low Residential District is 40 percent.
A neighbofiood meeting was held on August 24, 2004. Staff believes all of the concerns have been
addressed by the proposed design.
EXHIBIT `i' ~~
DRC ACTION AGENDA
DRC2005-00003 - AGUIRRE/BRUNO
May 17, 2005
Page 2
Staff Comments The following comments are intended to provide an outline for Committee
discussion.
Major Issues: The following broad design issues will be the focus of Committee discussion
regarding this project
In the Hillside Overlay, excavation ("cuY') or fill greater than 5 feet regwres Planning
Commission approval. Amounts in excess are discouraged and when viable alternatives exist,
staff will suggest to the applicant that they senously consider those alternatives first Similarly,
sensitivity to the surrounding neighbors' concerns, such as preservation of their views, and
architectural design compatibility with existing structures in the neighborhood are
recommended. There are two small areas where cut exceeds 5 feet (see Exhibits "A" and
"B") Staff believes that the following design features adequately address this concern
a. Stepped floors;
setbacks in excess of the minimums required by the Development Code, and
c relatively compact size.
These solutions are the result of discussions with the applicant and a neighborhood meeting
conducted on August 24, 2004 Staff believes that the applicant has made a good faith effort
to satisfy the intent of this ordinance The protect complies with the technical requirements of
the Hillside Development Regulations.
2 A Minor Exception is regwred for any wall between 6 feet and 8 feet in height (RCMC Section
1704.050 6.1.a.). The 3-foot to 4-foot high retaining wall along the west property line, when
combined with a 6-foot high garden wall, will require the submittal of a Minor Exception
application for review and approval by the City Planner pnor to construction. As alternative,
terraced walls separated by a minimum of 3 feet should be considered
Secondary Issues Once all of the major issues have been addressed, and time permitting, the
Committee will discuss the following secondary design issues:
The minimum separation between the driveway pavement and the property Ime is 5 feet.
Because the ratio of the dnveway at the southwest comer of the site precludes this separation,
the separation that the applicant has proposed is 3 feet.
Policy Issues The following items are a matter of Planning Commission policy and should be
incorporated into the project design vnthout discussion:
All of the walls exposed to public view, including retaining walls, shall be decorative (i e.
stucco, split-face, or slumpstone with a tnm cap)
Staff Recommendation: Staff recommends that the Committee approve the proposal as
submitted
Attachments
A--~n
DRC ACTION AGENDA
DRC2005-00003 - AGUIRRE/BRUNO .
May 17, 2005
Page 3
Desinn Review Committee Action.
Members Present McPhail, Stewart, Coleman
Staff Planner: Michael Smith
The Committee recommended approval contingent upon enhancements of the north and west
elevations, such as two-tone color and decorative window sdl.
~g
C~
~ = ~ 5;
~avA~ou
EXHIBIT
m ...
x
z
W 10 20 30 40 50
1316.7
T.. 2:1 MAX 1302.7 F
W
V
2:1 MA ~ 1307.5 TF
n ~ FRONT P OP. UNE
' SOUTFI.
V
~~
1320
1315
1310
EX. CU B do GUTTER
1305
10 20 30 40 50
SECTION E-E
HORIZ. SCALE 1' = 5'
VERT. SCALE 1' = 5'
• i •
1300
RESOLUTION NO. 05-42
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
RANCHO CUCAMONGA, CALIFORNIA, APPROVING HILLSIDE DESIGN
REVIEW DRC2005-00003, A REQUEST TO CONSTRUCT ATWO-STORY
SINGLE-FAMILY RESIDENCE WITH A FLOOR AREA OF 3,974 SQUARE
FEET (INCLUDING THE GARAGE, PATIOS, AND DECKS), ON A PARCEL
OF ABOUT 12,000 SQUARE FEET IN THE LOW RESIDENTIAL DISTRICT
(2-4 DWELLING UNITS PER ACRE), LOCATED WEST OF PREDERA
COURT ON THE NORTH SIDE OF CAMINO PREDERA, AND MAKING
FINDINGS IN SUPPORT THEREOF - APN. 0207-631-22.
A. ecitals
1 Sam Agwrre, Pam Aguirre, and Sarah Bruno filed an application for the approval of
Hillside Design Revew DRC2005-00003 as described in the title of this Resolution. Hereinafter in
this Resolution, the subbed Hillside Design Review is referred to as "the application."
2. On the 8th day of June 2005, the Planning Commission of the City of Rancho Cucamonga
conducted a meeting on the application and concluded said meeting on that date
All legal prerequisites prior to the adoption of this Resolution have occurred.
B. Resolution.
NOW, THEREFORE, it is hereby found, determined, and resolved bythe Planning Commission
of the City of Rancho Cucamonga as follows
1 This Commission hereby speafically finds that all of the facts set forth in the Recitals,
Part A, of this Resolution are true and correct.
2. Based upon the substantial evidence presented to this Commission during the
above-referenced meeting on June 8, 2005, mcludmg wntten and oral staff reports, this Commission
hereby specifically finds as follows.
a. The application applies to property in the Low Residential Distnd, located on the
north side of Camino Predera; and
b The subject property has an area of 12,203 square feet v~nth a street frontage of
about 80 feet and lot depth of about 155 feet, and
c The subbed property slopes from north to south with an elevation of 1,335 feet on
,the north (rear) side and an elevation of 1,304 feet on the south (front) side, and
d. The applicant proposes to construct a 2-story single-family residence and attached
2-car garage with a lot coverage of 23.5 percent; and
e. The first floor of the proposed house, mcludmg the garage, wdl have three stepped
pads v~nth finished floor elevations of 1,329.5 feet and 1,326.5 feet. The garage will have a finished
surface elevation of 1,322.5 feet; and
j~' d-~
PLANNING COMMISSION RESOLUTION NO. 05-42
DRC2005-00003 - AGUIRRE/BRUNO
June 8, 2005
Page 2
f. Excavation in excess of 5 feet will occur at two general locations at the dnveway at
the front of the property and at the northwest comer of the property. Excavations on the remainder
of the property will be limited to 5 feet or less; and
g. The combined quantity of excavation and fill will be about 1,000 cubic yards; and
h. The property to the north has an existing single-family residence; the propertyto the
south is vacant, and the properties to the east and west are vacant although one single-family
residence was recently approved for development on each (Hillside Design Review DRC2004-00375
and DRC2004-00630, respectively), and
i. On August 24, 2005, a neighborhood meeting was conducted to gather input and
comments from the owners of the surrounding properties on Camino Predere and immediatey to the
north on Red Hdl Country Club Dnve. The primary concern stated by those present was the potential
loss of views caused by new construction on currently vacant land along Camino Predera,
specifically on the south side of the street. As the applicant's property is on the north side of the
street, and is significantly lower than the house to the north, his design and grading will allow the
house to have 8 lower profile Any loss of views will be minimal.
j. The site is vacant and contains one tree and native grasses; and
k. The proposed residence is consistent vinth other single-family residential
developments in the area; and
I The proposed residence meets the intent and guidelines of the Hillside
Development Regulations.
3. Based upon the substantial evidence presented to this Commission dunng the
above-referenced meeting and upon the specific findings of facts set forth in paragraphs 1 and 2
above, this Commission hereby finds and concludes as follows
a The proposed project is consistent with the objectives of the General Plan; and
b. The proposed use is in accord with the objectives of the Development Code and the
purposes of the distnct in which the site is located; and
c. The proposed use is in compliance with each of the applicable provisions of the
Development Code; and
d The proposed use, together with the conditions applicable thereto, will not be
detnmental to the public health, safety, or welfare or materially injunous to properties or
improvements in the vicinity.
4. The Commission hereby finds and determines that the project identfied in this Resolution
is categoncally exempt from the requirements of the California Environmental Quality Act (CEQA) of
1970, as amended, and the Guidelines promulgated thereunder, pursuant to Section 15303(a) of the
State CEQA Guidelines.
5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above,
this Commission hereby approves the application subject to each and every condition set forth below
and in the Standard Conditions, attached hereto and incorporated herein by this reference.
PLANNING COMMISSION RESOLUTION NO 05-42
DRC2005-00003 - AGUIRRE/BRUNO
June 8, 2005
Page 3
Plamm~a Department
1) Approval is for the construction of a two-story, single-family residence
of 3,974 square feet, on a parcel located on the north side of Camino
Predera, west of Predera Court - APN: 0207-631-22.
2) Architectural details, finishes, trim, matenals, and color shall be un'ifortn
m appearance and design, and shall be applied on all elevations of the
house
3) Prior to the construction of a new penmeter wall on the west and east
sides of the subject property, a good faith effort shall be made to
coordinate the design and construction of this wall ninth the property
owners to the west and east to ensure that any grade differences are
minimized and that there are no "double-wall" conditions. Although
separate, approved building permits are required priorto construction of
this wall, ds location shall be shown m its entirety and with dimensions
and elevations (top/bottom of wall) on the Precise Grading Plan
4) The minimum honzontal distance between any retaining walls is 3 feet
(inside dimension) and shall inGude appropriate landscaping between
them. All walls shall have a decorative finish and a 2-inch decorative
cap. The mawmum allowable height of the retaining walls m the front
yard setback is 3 feet, measured from firnshed grade Although
separate, approved budding perrnts are required pnorto consWdion of
these walls; their location shall be shown on the Precse Grading Plan.
5) Walls moth a height m excess of 6 feet shall regwre the submittal of a
Minor Exception for revew and approval by the City Planner poor to
constructron
6) Vertical cuUfill shall not exceed 5 feet m depth anywhere on the
property, as measured from the natural grade, except at the two
locations identified in Exhibit E of the staff report.
7) Pnor to issuance of Grading Permt(s) and the removal of the tree that
is located near the northeast comer of the property, a Tree Removal
Perrnt (~nnth applicable fee) shall be submitted for review and approval
by the City Planner.
8) Front yard landscaping shall be installed poor to release of occupancy.
A minmum of 30 percent of the landscape material shall be large size
(minmum 24-inch box size trees, 10-gallon shrubs) mnthin the frontyard
and visible portions of the side yard in order to create a mature
appearance.
9) Any revisions to the Grading Plan, inctudmg changes in the quantities
or depth of cuUfill, moll regwre the review and approval by the Grading
Review Committee and Planning Commission.
~}- a,3
PLANNING COMMISSION RESOLUTION NO 05-42
DRC2005-00003 - AGUIRRE/BRUNO
June 8, 2005
Page 4
Enaineenna Department
1) The drainage runoff from this developed site shall not adversely affect
the ewsting homes/lots adjacent and downstream of this site.
2) Revise existing Public Street Improvement Plans, City Drawing
No. 922. Provide all missing public improvements inducting drive
approach and curbside drain outlet.
a) Curbside drain outlet(s) shall be constructed per City Standard
107-A Maintain the proposed curbside dram outlet Gear of the
dnve approach
b) The edge of the drive approach shall be a minimum 5 feet from
the property Ime Residential drive approach shall be constructed
per City Standard No.101, type R-1.
c) On the typical street section for Camino Predere, extend the
2 percenl parkway slope to 1 foot beyond the edge of the
sidewalk, then loin on-site grades with maximum 2.1 slopes.
3) Protect all existing street improvements m place inducting, but not
limited to, curb and gutter, sidewalk, streetlight, and pavement.
4) Protect all existing private drainage easement improvements along the
northwesterly property fine, or replace. Gean and maintain the private
drainage easement Swale and rrtamtam m a good working order. The
owner shall be responsible for all maintenance of drainage easement
facilities on this site.
5) Prior to any work being performed m the public right-of--way, fees shall
be paid and a construction perrnt shall be obtained from the Gty
Engineer's Office m addition to any other permits required.
6. The Secretary to this Commission shall certify to the adoption of this Resolution
APPROVED AND ADOPTED THIS 8TH DAY OF JUNE 2005
PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA
BY:
Rich Macias, Chairman
ATTEST:
Brad Buller, Secretary /~.. .^~ // nn
/ ' ~"
PLANNING COMMISSION RESOLUTION NO. 05-42
DRC2005-00003 - AGUIRRE/BRUNO
June 8, 2005
Page 5
i, Brad Buller, Secretary of the Planning Commission of the City of Rancho Cucamonga, do hereby
certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the
Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning
Commission held on the 8th day of June 2005, by the following vote-to-wit:
AYES: COMMISSIONERS.
NOES• COMMISSIONERS•
ABSENT: COMMISSIONERS•
tL_J
~~
COMMUNITY DEVELOPMENT•
DEPARTMENI~
STANDARD CONDITIONS
PROJECT #: DRC2005-00003
SUBJECT: HILLSIDE DESIGN REVIEW
APPLICANT: SAM AND PAM AGUIRRE AND SARAH BRUNO
LOCATION: NORTHSIDE OF CAMINO PREDERA, WEST OF PREDERA COURT-APN 0207-631-22
ALL OF THE FOLLOW/NG CONDITIONS APPLY TO YOUR PROJECT.
APPLICANT SHALL CONTACT THE PLANNING DEPARTMENT, (909) 477-2750, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
A. General Requirements coin Ietion Da
1 The applicant shall agree to defend at his sole expense any action brought against the City, its _/ /_
agents, officers, or employees, because of the issuance of such approval, or in the altemaWe, to
relingwsh such approval The applicant shall reimburse the City, its agents, officers, or
employees, for any Court costs and attorney's fees which the City, its agents, officers, or
employees maybe requred by a court to pay as a result of such action The City may, at ds sole
discretion, participate at its own expense in the defense of any such action but such partiapation
shall not relieve applicant of his obligations under this condition
2 Copies of the signed Planning Commission Resolution of Approval No. 05-42, Standard _/ /
Conditions, and all environmental mdigations shall be inGuded on the plans (full size) The
sheet(s) are for information only to all parties involved in the construction/grading actiwties and
are not required to be wet sealed/stamped by a licensed Engineer/Architect
B. Time Limits
1 Development/Design Review approval shall expue if budding permits are not issued or approved _/ /_
use has not commenced within 5 years from the date of approval No extensions are allowed
C. Site Development
1 The site shall be developed and maintained in accordance with the approved plans which inGude _/ /_
site plans, architectural elevations, exterior materials and colors, landscaping, sign program, and
grading on file in the Planning Department, the conditions contained herein, and Development
Code regulations
2 Prior to any use of the protect site or business activity being commenced thereon, all Conditions _/_/
of Approval shall be completed to the satisfaction of the Cdy Planner
,~-~.CP
1
Protect No DRC2005-00003
3 Occupancy of the faalities shall not commence until such time as all Uniform Bulding Code and
. State Fire Marshal regulations have been complied with Prior to occupancy, plans shall be
submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety
Department to show compliance The buildings shall be inspected for compliance prior to
occupancy
4 Revised site plans and building elevations incorporating all Conditions of Approval shall be
submitted for City Planner review and approval pnor to the issuance of budding permits
5 All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for
consistency pnor to issuance of any permits (such as grading, tree removal, encroachment,
budding, etc) or pnor to final map approval m the case of a custom lot subdivision, or approved
use has commenced, whichever comes first
6 Approval of this request shall not waive compliance Nnth all sections of the Development Code, all
other appl~ceble City Ordinances, and applicable Community or Specific Plans m effect at the
time of budding permit issuance
7 If no centralized trash receptacles are provided, all trash pick-up shall be for individual units with
all receptacles shielded from public view
8 All building numbers and mdmdual units shall be identified in a clear and concise manner,
including proper illumination
9 Six-foot decorative block walls shall be constructed along the protect perimeter. If a double wall
condition would result, the developer shall make a good faith effort to work with the adlommg
property owners to provide a single wall Developer shall notify, by mad, all contiguous property
owner at least 30 days pnor to the removal of any existing walls/ fences along the protect's
perimeter
• 10 Construct block walls between homes (i e , along interior side and rear property Imes), rather than
wood fencng for permanence, durability, and design consistency
11 Access gates to the rear yards shall be constructed from a material more durable than wood
gates Acceptable materials include, but are not limited to, wrought iron and PVC
12 For residential development, return walls and comer side walls shall be decorative masonry
13 Slope fencing along side property Imes may be wrought iron or black plastic coated chain link to
maintain an open feeling and enhance views.
D. Building Design
All roof appurtenances, including air conddioners and other roof mounted equipment and/or
protections, shall be shielded from view and the sound buffered from adjacent properties and
streets as regwred by the Planning Department Such screening shall be architecturally
integrated with the budding design and constructed to the satisfaction of the City Planner Details
shall be mGuded in bwldmg plans
E. Parking and Vehicular Access (indicate details on building plans)
Multiple car garage driveways shall be tapered down to a standard two-car width at street
F. Landscaping
1 A detailed landscape and irrigation plan, including slope planting and model home landscaping m
the case of residential development, shall be prepared by a licensed landscape architect and
submitted for City Planner review and approval prior to the issuance of building permits or pnor
final map approval m the case of a custom lot subdivision
f~~-1
ComoleGOn Date
/ /
/ /
/ /
/ /
/ /
/ /
/ /
_/-/.
/ /
/ /
/ /
/ /
/ /
/ /
Project No DRC2005-00003
Comolehon Date
2 All private slopes of 5 feet or more in vertical height and of 5 1 or greater slope, but less than 2 1
slope, shall be, at mwmum, irrigated and landscaped with appropriate ground cover for erosion
control Slope planting requred by this section shall include a permanent irrigation system to be
installed by the developer prior to occupancy.
3 All private slopes m excess of 5 feet, but less than 8 feet in vertical height and of 2 1 or greater
slope shall be landscaped and irrigated for erosion control and to soften their appearance as
follows one 15-gallon or larger size tree per each 150 sq ft of slope area, 1-gallon or larger size
shrub per each 100 sq ft of slope area, and appropriate ground cover In addition, slope banks
in excess of 8 feet in vertical height and 2 1 or greater slope shall also include one 5-gallon or
larger size tree per each 250 sq ft of slope area Trees and shrubs shall be planted in
staggered clusters to soften and vary slope plane Slope planting regwred by this section shall
inGude a permanent irrigation system to be installed by the developer prior to occupancy
4 For single-family residential development, all slope planting and irigation shall be continuously
maintained in a healthy and thriving condition by the developer until each indmdual unit ~s sold
and occupied by the buyer Prior to releasing occupancy for those units, an inspection shall be
conducted by the Planning Department to determine that they are in satisfactory condition
5 Front yard and comer side yard landscaping and irrigation shall be regwred per the Development
Code This regwrement shall be in addition to the regwred street trees and slope planting
6 The final design of the perimeter parkways, walls, landscaping, and sidewalks shall be inGuded in
the required landscape plans and shall be subject to City Planner revew and approval and
coordinated for consistency with any parkway landscaping plan which may be requred by the
Engineering Department
7 Landscaping and irrigation systems regwred to be installed within the public right-of-way on the
perimeter of this project area shall be continuously maintained by the developer.
8. All walls shall be provided with dewrative treatment If located in public maintenance areas, the
design shall be coordinated with the Engineering Department
G. Other Agencies
The applicant shall contact the U S Postal Service to determine the appropriate type and location
of mailboxes Multi-family residential developments shall prowde a solid overhead structure for
mailboxes Hnth adequate lighting The final location of the mailboxes and the design of the
overhead structure shall be subject to City Planner review and approval prior to the issuance of
bwlding permts
APPLICANT SHALL CONTACT THE BUILDING AND SAFETY DEPARTMENT, (909) 477-2710,
FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS:
NOTE: ANY REVISIONS MAY VOID THESE REQUIREMENTS AND NECESSITATE ADDITIONAL REVIEW(S)
H. General Requirements
Submit five complete sets of plans including the following
a Site/Plot Plan,
b Foundation Plan,
c Floor Plan,
d Ceding and Roof Framing Plan,
e Electrical Plans (2 sets, detached) mcludmg the size of the main switch, number and size
of service entrance conductors, panel schedules, and single line diagrams,
_/_/~
/ /
/ /
/ /
r i
/ /
-~ ~ .
•
;~ a ~'
Protect No DRC2005-00003
f Plumbing and Sewer Plans, including isometrics, underground diagrams, water and waste
diagram, sewer or septic system location, fixture units, gas piping, and heating and air
conddioning, and
g Planning Department Protect Number (DRC2005-00003) Dearly identified on the outside of
all plans
Submit lwo sets of structural calculations, energy conservation calculations, and a sods report
Architect's/Engineer's stamp and "wet" signature are required prior to plan check submittal.
Contractors must show proof of State and City licenses and Workers' Compensation coverage to
the City prior to permd issuance
Separate permits are regwred for fencing and/or walls
I. Site Development
1 Plans shall be submitted for plan check and approved pnor to construction All plans shall be
marked with the project file number (DRC2005-00003) The applicant shall complyHnth the latest
adopted Califomia Codes, and all other applicable codes, ordinances, and regulations in effect at
the time of permit application Contact the Building and Safety Department for availability of the
Code Adoption Ordinance and applicable handouts
2 Prior to issuance of building permits for a new residential project or motor addition, the applicant
shall pay development fees at the established rate Such fees may include, but are not limited to
City Beautification Fee, Park Fee, Drainage Fee, Transportation Development Fee, Permit and
Plan Check Fees, Construction and Demolition Diversion Program deposit and fees and School
Fees Applicent shall provide a wpy of the school fees receipt to the Budding and Safety
. Department pnor to permit issuance
3 Street addresses shall be provided by the Bulding and Safety Official after tract/parcel map
recordation and pnor to issuance of building permits
4 Construction activity shall not occur between the hours of 8 00 p m and 6 30 a m Monday
through Saturday, with no construction on Sunday or holidays
J. New Structures
1 Provide compliance with the California Building Code (CBC) for property line clearances
considering use, area, and fire-resistiveness
2 Provide compliance with the California Budding Code for required occupancy separations
3 Roofing material shall be installed per the manufacturer's "high wind" instructions.
K. Grading
1 Grading of the subject property shall be in accordance wrath Califomia Bulding Code, City Grading
Standards, and accepted grading practices. The final grading plan shall be in substantial
conformance with the approved grading plan
2 A soils report shall be prepared by a qualified engineer licensed by the State of California to
perform such work
3 A geological report shall be prepared by a qualified engineer or geologist and submitted at the
time of application for grading plan check
ComoleGOn Date
/ /
/ /
/ /
/ /
/ /
-/-/-
/ /
/ /
/ /
/ /
/ /
/ /
/ /
~" ~ t
Project No DRC2005-00003
Comolefton Date
4 The final grading, appropriate certifications and compaction reports shall be completed, _/_l~
submitted, and approved by the Building and Safety Official pnor to the issuance of budding
permits
5 A separate grading plan check submittal is required for all new construction projects and for _/_/_
existing buildings where improvements being proposed will generate 50 cubic yards or more of
combined cut and fill The grading plan shall be prepared, stamped, and signed by a California
registered Civil Engineer
APPLICANT SHALL CONTACT THE POLICE DEPARTMENT, (909) 477-2800, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
L. Security Hardware
1 A secondary locking device shall be installed on ail sliding glass doors _/-/-
2 One-inch single cylinder dead bolts shall be installed on all entrance doors If vtnndows are vnthm _/_/_
40 inches of any lockmg device, tempered glass or a double cylinder dead bolt shall be used
3 All garage or rolling doors shall have slide bolts or some type of secondary lockmg devices /_/_
M. Windows
1 All sliding glass windows shall have secondary locking devices and should not be able to be Irfted _/_/_
from frame or track m any manner
N. Building Numbering ,
1 Numbers and the backgrounds shall be of contrasting color and shall be reflective for rnghttime _/_/_
visibility
APPLICANT SHALL CONTACT THE FIRE SAFETY DEPARTMENT, FIRE PROTECTION
PLANNING SERVICES AT, (909) 477-2770, FOR COMPLIANCE WITH THE FOLLOWING
CONDITIONS:
SEE ATTACHED
T~~Q
5
/ ~ ,,,v.. Rancho Cucamonga Fire Protection District
x
Fire Construction Services
STANDARD CONDITIONS
Apnl 14, 2005
Samuel Aguirre
8044 Camino Predera
DRC2005-00003
THE FOLLOWING STANDARD CONDITIONS APPLY TO THIS PROJECT.
FSC-2 Fire Flow
1. The regwred fire flow for this project is 2,000 gallons per minute at a minimum residual
pressure of 20-pounds per square mch. This regwrement is made m accordance with Fire Code
Appendix III-A, as adopted by the Fire District Ordinances For structures m excess of 3,600
square feet use CFC Table A-III-A-1.
~. On all site plans to be submitted for review, show all fire hydrants located within 600-feet of the
proposed project site.
Please complete the following prior to the issuance of any building permits:
1. Fire Flow: A current fire flow letter from CCWD must be received. The applicant is responsible
for obtaining the fire flow information from CCWD and submitting the letter to Fire Construction
Services.
2. Address: Note on the plans that pnor to the granting of occupancy, single-family dwellings shall
post the address with minimum 4-inch numbers on a contrasting background. The numbers
shall be internally or externally illuminated dunng periods of darkness. The numbers shall be
visible from the street. When bwlding setback from the public roadway exceeds 100-feet,
additional 4-mch numbers shall be displayed at the property entry
~-