Loading...
HomeMy WebLinkAbout13-39 - Resolutions RESOLUTION NO. 13-39 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING DEVELOPMENT REVIEW DRC2013-00018 THE CONSTRUCTION OF 53 SINGLE-FAMILY RESIDENCES, ON 40.12 ACRES OF LAND WITHIN THE VERY LOW RESIDENTIAL DISTRICT OF THE ETIWANDA NORTH SPECIFIC PLAN, LOCATED AT THE NORTHWEST CORNER OF WARDMAN BULLOCK ROAD AND WILSON AVENUE; AND MAKING FINDINGS IN SUPPORT THEREOF -APN: 0226-081-06 AND 06. A. Recitals. 1. Steven Ford, on behalf of Pulte Homes, filed an application for the approval of Development Review DRC2013-00018, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Development Review request is referred to as "the application." 2. On the 25th day of September 2013, the Planning Commission of the City of Rancho Cucamonga conducted a duly notice public hearing on the application and concluded said hearing on that date. 3. All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing on September 25, 2013, including written and oral staff reports,this Commission hereby specifically finds as follows: a. The application applies to the property located at the northwest corner of Wardman Bullock Road and Wilson Avenue, with a street frontage of 1,287 feet and lot depth of approximately 1,313 feet and is presently vacant land; and b. The property to the north of the subject site is a partially built subdivision of single-family residences; the property to the south and east across Wardman Bullock Road consists of existing single-family residences; and the property to the west is the flood control basin;and C. The project consists of a Development Review of 53 single-family residential lots on 40.12 acres of vacant land; and d. The project also has a Minor Exception application being concurrently processed for the increased height of the tract boundary walls along the north and west sides of the project; and e. The project conforms to the basic Development Standards of the Etiwanda North Specific Plan with required architectural elevations, slope requirements, and overall project density. PLANNING COMMISSION RESOLUTION NO. 13-39 DR DRC2013-00018 — PULTE HOMES September 25, 2013 Page 2 3. Based upon the substantial evidence presented to this Commission during the above- referenced public hearing and upon the specific findings of facts set forth in Paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The proposed project is consistent with the objectives of the General Plan by providing a variety of housing units that are compatible with the surrounding area; and b. The proposed use is in accord with the objectives of the Development Code and the purposes of the district in which the site is located by adhering to all setback, height, and density regulations that govern the area where these homes are being constructed; and C. The proposed use is in compliance with each of the applicable provisions of the Development Code in that single-family residences are an approved use within the Very Low Residential District of the Etiwanda North Specific Plan; and d. The proposed use, together with the conditions applicable thereto, will not be detrimental to the public health, safety or welfare, or materially injurious to properties or improvements in the vicinity. 4. Based upon the facts and information contained in the application, together with all written and oral reports included for the environmental assessment for the application, the Planning Commission finds that no subsequent or supplemental environmental document is required pursuant to the California Environmental Quality Act(CEQA) in connection with the review and approval of this application based upon the following findings and determinations: a. Pursuant to the California Environmental Quality Act("CEQA") and the City's local CEQA Guidelines, the City adopted a Mitigated Negative Declaration in January.9, 2013, in connection with the City's approval of Tentative Tract Map SUBTT18741. 'Pursuant to CEQA Guidelines Section 15162, no subsequent or supplemental EIR or Negative Declaration is required in connection with subsequent discretionary approvals of the same project unless: (i) substantial changes are proposed to the project that indicate new or more severe impacts on the environment; (ii)substantial changes have occurred in the circumstances under which the project was previously reviewed that indicates new or more severe environmental impacts;or(iii)new important information shows the project will have new or more severe impacts than previously considered; or (iv) additional mitigation measures are now feasible to reduce impacts or different mitigation measures can be imposed to substantially reduce impacts. b. The Planning Commission finds, in connection with the Development Review,that substantial changes to the project or the circumstances surrounding the project have not occurred which would create new or more severe impacts than those evaluated in the previous Mitigated Negative Declaration. The development review proposes the construction of 53 single-family residences'as evaluated in the previous initial study. Staff further finds that the project will not have one or more significant effects not discussed in the previous Mitigated Negative Declaration, not have more severe effects than previously analyzed, and that additional or different mitigation measures are not required to reduce the impacts of the project to a level of less-than-significant. The proposed construction of the single-family residences meets the requirements of the development code and specific plan in which the project site is located. C. Based on these findings and all evidence in the record, the Planning Commission concurs with the staff determination that no additional environmental review is required pursuant to CEQA in connection with the City's consideration of the Development Review. PLANNING COMMISSION RESOLUTION NO. 13-39 DR DRC2013-00018— PULTE HOMES September 25, 2013 Page 3 5. Based upon the findings and conclusions set forth in Paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth below and in the Standard Conditions, attached hereto, and incorporated herein by this reference. Planning Department 1) Approval is for the development of 53 single-family homes within tract 18741. 2) The applicant shall adhere to all Standard and Special Conditions of Approval from Tentative Tract Map SUBTT18741 Planning Commission Resolution No. 13-10. 3) The applicant shall implement all mitigation measures adopted for Tentative Tract Map SUBTT18741, as shown in Planning Commission Resolution No. 13-10. 4) All driveways shall have a maximum grade of 10 percent. If necessary, driveways shall be lengthened and the garage setbacks increased in order to achieve a 10 percent grade. 5) Boulders from the project site shall be utilized and integrated as part of the front yard landscape plan, per the Master Plan Resolution of Approval. 6) Man doors leading from the garage to the rear yard shall be raised panel to compliment the architectural style of the residence. 7) Coach light styles that are utilized in the front of the homes shall also be utilized around the rest of the house to compliment the architectural style of the residence. 8) The driveways shall be scored in a horizontal pattern for additional entryway detail. Engineering Services Department 1) The applicant shall adhere to all Standard and Special Conditions of Approval from Tentative Tract Map SUBTT18741, as shown in Planning Commission Resolution No. 13-10. 2) Add the following note to any private landscape plans that show street trees or LMD areas: "All improvements within the public right-of-way, including street trees and Landscape Maintenance District areas, shall be installed per the public improvement plans." If there is a discrepancy between the public and private plans, the street improvement plans will govern. PLANNING COMMISSION RESOLUTION NO. 13-39 DR DRC2013-00018— PULTE HOMES September 25, 2013 Page 4 6. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 25TH DAY OF SEPTEMBER 2013. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA /W BY: dl-v Frances Howdyshell, Chairman ATTEST: Candyqjurneft, Secretary I, Candyce Burnett, Secretary of the Planning Commission for the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed,and adopted by the Planning Commission of the City of Rancho Cucamonga,at a regular meeting of the Planning Commission held on the 25th day of September 2013, by the following vote-to-wit: AYES: COMMISSIONERS: FLETCHER,HOWDYSHELL,MUNOZ,OAXACA,WIMBERLY NOES: COMMISSIONERS: NONE ABSENT: COMMISSIONERS: NONE ABSTAIN: COMMISSIONERS: NONE COMMUNITY DEVELOPMENT DEPARTMENT STANDARD. CONDITIONS PROJECT#: DRC2013-00018 SUBJECT: DEVELOPMENT REVIEW APPLICANT: PULTE HOMES NORTHWEST CORNER OF WARDMAN BULLOCK ROAD AND WILSON AVENUE - LOCATION: APN: 0226-081-05 AND 06. ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT. APPLICANT SHALL CONTACT THE PLANNING DEPARTMENT, (909) 477-2750, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: A. General Requirements Completion Date 1. The applicant shall agree to defend at his sole expense any action brought against the City, its agents, officers, or employees, because of the issuance of such approval, or in the alternative, to relinquish such approval. The applicant shall reimburse the City, its agents, officers, or employees, for any Court costs and attorney's fees which the City, its agents, officers, or employees may be required by a court to pay as a result of such action. The City may, at its sole discretion, participate at its own expense in the defense of any such action but such participation shall not relieve applicant of his obligations under this condition. 2. Copies of the signed Planning Commission Resolution of Approval No. 13-39 or Approval _/_/_ Letter, Standard Conditions, and all environmental mitigations shall be included on the plans (full size). The sheet(s) are for information only to all parties involved in the construction/grading activities and are not required to be wet sealed/stamped by a licensed Engineer/Architect. 3. The applicant shall be required to pay any applicable Fish and Game fees as shown below. _/_I_ The project planner will confirm which fees apply to this project. All checks are to be made payable to the Clerk of the Board Supervisors and submitted to the Planning Commission Secretary prior to the Planning Commission or Planning Manager hearing. a) Notice of Exemption - $50 X B. Time Limits 1. Any approval shall expire if Building Permits are not issued or approved use has not commenced within 5 years from the date of approval or a time extension has been granted. 1 Project No. ORC2013-00018 Completion Date C. Site Development 1. The site shall be developed and maintained in accordance with the approved plans which include Site Plans, architectural elevations, exterior materials and colors, landscaping, sign program, and grading on file in the Planning Department, the conditions contained herein, the Development Code regulations, and the Etiwanda North Specific Plan. 2. Prior to any use of the project site or business activity being commenced thereon, all _/_/_ Conditions of Approval shall be completed to the satisfaction of the Planning Manager. 3. Occupancy of the facilities shall not commence until such time as all California Building Code and State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety Services Department to show compliance. The buildings shall be inspected for compliance and final acceptance granted prior to occupancy. 4. Revised Site Plans and building elevations incorporating all Conditions of Approval shall be submitted for Planning Manager review and approval prior to the issuance of Building Permits. 5. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for consistency prior to issuance of any permits (such as grading, tree removal, encroachment, building, etc.) or prior to final map approval in the case of a custom lot subdivision, or approved use has commenced, whichever comes first. 6. Approval of this request shall not waive compliance with all sections of the Development Code, all other applicable City Ordinances, and applicable Community, Specific Plans and/or Master Plans in effect at the time of Building Permit issuance. 7. All ground-mounted utility appurtenances such as transformers, AC condensers, etc., shall be located out of public view and adequately screened through the use of a combination of concrete or masonry walls, berming, and/or landscaping to the satisfaction of the Planning Manager. For single-family residential developments, transformers shall be placed in underground vaults. 8. Street names shall be submitted for Planning Manager review and approval in accordance with the adopted Street Naming Policy prior to approval of the final map 9. All building numbers and individual units shall be identified in a clear and concise manner, including proper illumination and in conformance with Building and Safety Services Department standards, the Municipal Code and the Rancho Cucamonga Fire Department (RCFD) Standards. 10. A detailed plan indicating trail widths, maximum slopes, physical conditions, fencing, and weed control, in accordance with City Master Trail drawings, shall be submitted for Planning Manager review and approval prior to approval and recordation of the Final Tract Map and prior to approval of street improvement and grading plans. Developer shall upgrade and construct all trails, including fencing and drainage devices, in conjunction with street improvements. 11. Local Feeder Trail entrances shall also provide access for service vehicles, such as _/_/_ veterinarians or hay deliveries, including a 12-foot minimum drive approach. Entrance shall be gated provided that equestrian access is maintained through step-throughs in accordance with Engineering Services Department Standard Drawing 1006-B and 1007-B. 12. Local Feeder Trail grades shall not exceed 0.5 percent at the downstream end of a trail for a distance of 25 feet behind the public right-of-way line to prohibit trail debris from reaching the street. Drainage devices may be required by the Building and Safety Official. 2 Project No. DRC2013-00018 Completion Date 13. Provide a 24-foot by 24-foot or 12-foot by 48-foot corral area in the rear yard adjacent to the Local Feeder Trail. Grade access from corral to trail with a maximum slope of 5:1 and a minimum width of 10 feet. 14. For single-family residential development within the Equestrian/Rural Overlay District, at least one model home shall be provided with a constructed 24-foot by 24-foot corral with appropriate fencing. 15. Where corner side, interior side or rear yard property lines are adjacent to local equestrian I !_ trails, construct minimum 6-foot high decorative masonry walls. Decorative masonry shall mean split-face double sided block, 'slump stone' or an alternative material that is acceptable to the Design Review Committee. 16. The Covenants, Conditions, and Restrictions (CC&Rs) shall not prohibit the keeping the equine animals where zoning requirements for the keeping of said animals have been met. Individual lot owners in subdivisions shall have the option of keeping said animals without the necessity of appealing to boards of directors of homeowners' associations for amendments to the CC&Rs. 17. The Covenants, Conditions, and Restrictions (CC&Rs) and Articles of Incorporation of the Homeowners' Association are subject to the approval of the Planning and Engineering Services Department and the City Attorney. They shall be recorded concurrently with the Final Map or prior to the issuance of Building Permits, whichever occurs first. A recorded copy shall be provided to the City Engineer. The Homeowners' Association shall submit to the Planning Department a list of the name and address of their officers on or before January 1 of each and every year and whenever said information changes. 18. All parkways, open areas, and landscaping shall be permanently maintained by the property owner, homeowners' association, or other means acceptable to the City. Proof of this landscape maintenance shall be submitted for Planning Manager and Engineering Services Department review and approved prior to the issuance of Building Permits. 19. Solar access easements shall be dedicated for the purpose of assuming that each lot or dwelling unit shall have the right to receive sunlight across adjacent lots or units for use of a solar energy system. The easements may be contained in a Declaration of Restrictions for the subdivision which shall be recorded concurrently with the recordation of the final map or issuance of permits, whichever comes first. The easements shall prohibit the casting of shadows by vegetation, structures, fixtures, or any other object, except for utility wires and similar objects. 20. The developer shall submit a construction access plan and schedule for the development of all lots for Planning Manager and Engineering Services Department approval; including, but not limited to, public notice requirements, special street posting, phone listing for community concerns, hours of construction activity, dust control measures, and security fencing. 21. Six-foot decorative block walls shall be constructed along the project perimeter. If a double wall condition would result, the developer shall make a good faith effort to work with the adjoining property owners to provide a single wall. Developer shall notify, by mail, all contiguous property owners at least 30 days prior to the removal of any existing walls/fences along the project perimeter. 22. Construct block walls between homes (i.e., along interior side and rear property lines), rather than wood fencing for permanence, durability, and design consistency. 23. Access gates to the rear yards shall be constructed from a material more durable than wood gates. Acceptable materials include, but are not limited to, wrought iron and PVC. 24. For residential development, return walls and corner side walls shall be decorative masonry. 3 Project No. DRC2013-00018 Completion Date 25. Slope fencing along side property lines may be wrought iron or black plastic coated chain link to maintain an open feeling and enhance views. 26. On corner side yards, provide minimum 5-foot setback between walls/fences and sidewalk. The 5-foot wall/fence setback and the parkway shall have landscape and irrigation in addition to the required street trees. Detailed landscape and irrigation plans shall be submitted for Planning Manager review and approval prior to issuance of Building Permits. The parkway landscaping including trees, shrubs, ground covers and irrigation shall be maintained by the property owner. The developer shall provide each prospective buyer written notice of the parkway maintenance requirement, in a standard format as determined by the Planning Manager, prior to accepting a cash deposit on any property. 27. Where rock cobble is used, it shall be real river rock. Other stone veneers may be manufactured products. D. Building Design 1. For all residential development, provide conduit from each unittlot and a pull box to connect _/_/_ to the street. Provide interior structured wiring for each house/building with minimum Category 5 copper wire, Radio Grade 6 coaxial cable, and a central distribution panel, prior to release of occupancy (fiber-to-the building, FTTB). Plans shall be submitted for Planning Manager and Building Official review and approval prior to issuance of Building Permits. E. Landscaping 1. A detailed landscape and irrigation plan, including slope planting and model home landscaping in the case of residential development, shall be prepared by a licensed landscape architect and submitted for Planning Manager review and approval prior to the issuance of Building Permits for the development or prior final map approval in the case of a custom lot subdivision. For development occurring in the Very High Fire Hazard Severity Zone, the landscape plans will also be reviewed by Fire Construction Services. 2. All private slopes of 5 feet or more in vertical height and of 5:1 or greater slope, but less than 2:1 slope, shall be, at minimum, irrigated, and landscaped with appropriate ground cover for erosion control. Slope planting required by this section shall include a permanent irrigation system to be installed by the developer prior to occupancy. 3. All private slopes in excess of 5 feet, but less than 8 feet in vertical height and of 2:1 or greater slope shall be landscaped and irrigated for erosion control and to soften their appearance as follows: one 15-gallon or larger size tree per each 150 sq. ft. of slope area, 1-gallon or larger size shrub per each 100 sq. ft. of slope area, and appropriate ground cover. In addition, slope banks in excess of 8 feet in vertical height and 2:1 or greater slope shall also include one 5-gallon or larger size tree per each 250 sq. ft. of slope area. Trees and shrubs shall be planted in staggered clusters to soften and vary slope plane. Slope planting required by this section shall include a permanent irrigation system to be installed by the developer prior to occupancy. 4. For single-family residential development, all slope planting and irrigation shall be continuously maintained in a healthy and thriving condition by the developer until each individual unit is sold and occupied by the buyer. Prior to releasing occupancy for those units, an inspection shall be conducted by the Planning Department to determine that they are in satisfactory condition. 5. Front yard and corner side yard landscaping and irrigation shall be required per the Development Code. This requirement shall be in addition to the required street trees and slope planting. 4 Project No. DRC2013-00018 Completion Date 6. The final design of the perimeter parkways, walls, landscaping, and sidewalks shall be included in the required landscape plans and shall be subject to Planning Manager review and approval and coordinated for consistency with any parkway landscaping plan which may be required by the Engineering Services Department. 7. All walls shall be provided with decorative treatment. If located in public maintenance areas, the design shall be coordinated with the Engineering Services Department. 8. Landscaping and irrigation shall be designed to conserve water through the principles of water efficient landscaping per Development Code Chapter 17.82. F. Environmental 1. Mitigation measures are required for the project. The applicant is responsible for the cost of implementing said measures, including monitoring and reporting. Applicant shall be required to post cash, letter of credit, or other forms of guarantee acceptable to the Planning Manager in the amount of $ 581 prior to the issuance of Building Permits, guaranteeing satisfactory performance and completion of all mitigation measures. These funds may be used by the City to retain consultants and/or pay for City staff time to monitor and report on the mitigation measures. Failure to complete all actions required by the approved environmental documents shall be considered grounds for forfeit. 2. In those instances requiring long term monitoring (i.e. beyond final certificate of occupancy), the applicant shall provide a written monitoring and reporting program to the Planning Manager prior to issuance of Building Permits. Said program shall identify the reporter as an individual qualified to know whether the particular mitigation measure has been implemented. G. Other Agencies 1. The applicant shall contact the U.S. Postal Service to determine the appropriate type and location of mailboxes. Multi-family residential developments shall provide a solid overhead structure for mailboxes with adequate lighting. The final location of the mailboxes and the design of the overhead structure shall be subject to Planning Manager review and approval prior to the issuance of Building Permits. APPLICANT SHALL CONTACT THE BUILDING AND SAFETY SERVICES DEPARTMENT, (909) 477-2710, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: NOTE: ANY REVISIONS MAY VOID THESE REQUIREMENTS AND NECESSITATE ADDITIONAL REVIEW(S). H. Building and Safety VHFHSZ Tract Standard Conditions NOTE: The construction of this tract must be in accordance with the approved Fire Protection Plan and/or the California Building; this tract is located in the VHFHSZ. General Requirements 1. Submit five complete sets of plans including the following: a. Site/Plot Plan; b. Foundation Plan and reverse foundation plan (when applicable); C. Floor Plan; d. Roof and Floor Framing Plan and reverse Roof and Floor Framing Plan (when applicable); 5 Project No. DRC2013-00018 Completion Date e. Electrical Plans (2 sets, detached) including the size of main switch, number and size of service entrance conductors, panel schedules, and single line diagrams; f. Plumbing and Sewer Plans, including isometrics, underground diagrams, water and waste diagram, sewer or septic system location, fixture units, gas piping, and heating and air conditioning; and g. Planning Department Project Number (DRC2013-00018) clearly identified on the outside of all plans. 2. Submit two sets of structural calculations, two sets of energy conservation calculations, and a soils report. Architect's/Engineer's stamp and "wet" signature are required prior to plan check submittal. 3. Contractors must show proof of State and City licenses and Workers' Compensation coverage to the City,prior to permit issuance. 4. Separate permits are required for fencing and/or walls. 5. Developers wishing to participate in the Community Energy Efficiency Program (CEEP) can contact the Building and Safety Services Department staff for information and submittal requirements. Site Development 1. Plans shall be submitted for plan check and approved prior to construction. All plans shall be marked with the project file number(DRC2013-00018). The applicant shall comply with the latest adopted California Codes, and all other applicable codes, ordinances, and regulations in effect at the time of permit application. Contact the Building and Safety Services Department for availability of the Code Adoption Ordinance and applicable handouts. 2. Prior to issuance of Building Permits for a new residential project or major addition, the applicant shall pay development fees at the established rate. Such fees may include, but are not limited to: City Beautification Fee, Park Fee, Drainage Fee, Transportation Development Fee, Permit and Plan Check Fees, and School Fees. Applicant shall provide a copy of the school fees receipt to the Building and Safety Services Department prior to permit issuance. 3. The Building and Safety Official shall provide street addresses after tract/parcel map recordation and prior to issuance of Building Permits. 4. Construction activity shall not occur between the hours of 8:00 p.m. and 6:30 a.m. Monday through Saturday, with no construction on Sunday or holidays. New Structures 1. Provide compliance with the California Residential/Code Building Code (CBC/CRC) for property line clearances considering use, area, and fire-resistive construction. 2. Construction of the home must be in accordance with the approved Fire protection Plan and/or Chapter 7A of the CBC; this tract is located in the VHFHSZ. 3. Provide compliance with the California Building Code for required occupancy separations. 4. The structures in this tract must be equipped with automatic fire sprinkler in accordance with the approved Fire protection Plan and The California Residential Code. 6 Project No. DRC2013-00018 completion Date 5. Roofing material shall be installed per the manufacturer's"high wind" instructions. I. Grading 1. Grading of the subject property shall be in accordance with current adopted California Building Code, City Grading Standards, and accepted grading practices. The grading and drainage plan(s) shall be in substantial conformance with the approved conceptual grading and drainage plan. 2. A soils report shall be prepared by a qualified engineer licensed by the State of California to perform such work. Two copies will be provided at grading and drainage plan submittal for review. Plans shall implement design recommendations per said report. 3. A geologic report shall be prepared by a qualified engineer or engineering geologist and submitted at the time of application for Grading and Drainage Plan review. 4. The final Grading and Drainage Plan, appropriate certifications and compaction reports shall be completed, submitted, and approved by the Building and Safety Official prior to the issuance of Building Permits. 5. A separate Grading and Plan check submittal is required for all new construction projects and for existing buildings where improvements being proposed will generate 50 cubic yards or more of combined cut and fill. The Grading and Drainage Plan shall be prepared, stamped, and wet signed by a California licensed Civil Engineer. 6. If human remains are discovered on-site before or during grading, no further disturbance shall occur until the County Coroner has made a determination of origin and disposition pursuant to Public Resources Code Section 5097.98 and California Health and Safety Code Section 7050.5. 7. The applicant shall comply with the City of Rancho Cucamonga Dust Control Measures and place a dust control sign on the project site prior to the issuance of a Grading Permit. 8. If a Rough Grading and Drainage Plan/Permit are submitted to the Building and Safety Official for review, that plan shall be a separate plan/permit from the Precise Grading and Drainage Plan/Permit. 9. It shall be the responsibility of the applicant to acquire any required off-site drainage easements prior to the issuance of a Grading Permit. 10. It shall be the responsibility of the applicant to acquire any required off-site drainage acceptance letter(s) from adjacent downstream property owner(s) or discharge flows in a natural condition (concentrated flows are not accepted) and shall provide the Building and Safety Official a drainage study showing the proposed flows do not exceed the existing flows prior to the issuance of a Grading Permit. 11. It shall be the responsibility of the applicant to obtain written permission from the adjacent property owners to construct walls on property lines or provide a detail(s) showing the perimeter wall(s) to be constructed off-set from the property line. 12. The Grading and Drainage Plan shall implement City Standards for on-site construction where possible, and provide details for all work not covered by City Standard Drawings. 13. All slopes shall be a minimum 2-foot off-set from the public right-of-way or adjacent private property. 7 Project No. DRC2013-00018 Completion Date 14. Private sewer, water, and storm drain improvements will be designed per the latest adopted _/_/ California Plumbing Code. 15. The maximum parking stall gradient is 5 percent. Accessibility parking stall grades shall be constructed per the current adopted California Building Code. 16. The final Grading and Drainage Plan shall show existing topography a minimum of 100 feet beyond the project boundary. 17. The applicant shall provide a grading agreement and grading bond for all cut and fill I /_ combined exceeding 5,000 cubic yards prior to issuance of a Grading Permit. The grading agreement and bond shall be approved by the Building and Safety Official. 18. Provide documentation for CVWD sewer off-set program to the Building and Safety Official for review prior to issuance of a Grading Permit. 19. This project shall comply with the accessibility requirements of the current adopted California Building Code. 20. The precise Grading and Drainage Plan shall follow the format provided in the City of Rancho Cucamonga handout"Information for Grading Plans and Permit." 21. Grading Inspections: a. Prior to the start of grading operations the owner and grading contractor shall request a pre-grading meeting. The meeting shall be attended by the project owner/representative, the grading contractor, and the Building Inspector to discuss about grading requirements and preventive measures, etc. If a pre-grading meeting is not held within 24 hours from the start of grading operations, the Grading Permit may be subject to suspension by the Building Inspector; b. The grading contractor shall call into the City of Rancho Cucamonga Building and Safety Services Department at least 1 working day in advance to request the following inspections prior to continuing grading operations: L The bottom of the over-excavation; ii. Completion of rough grading - The grading contractor or owner shall submit to the Permit Technicians (Building and Safety Services Department front counter) an original and a copy of the Pad Certifications to be prepared by and properly wet signed and sealed by the Civil Engineer and Soils Engineer of Record; iv. The rough grading certificates and the compaction reports will be reviewed by the Associate Engineer or a designated person and approved prior to the issuance of a Building Permit. 22. Prior to the issuance of the Certificate of Occupancy the engineer of record shall certify the functionality of the storm water quality management plan (WQMP) best management practices (BMP) devices. 23. Roof storm water is not permitted to flow over the public parkway and shall be directed to an under parkway culvert per City of Rancho Cucamonga requirements prior to issuance of a Grading Permit. J. Water Quality Management Plan 8 Project No. DRC2013-00018 Completion Date 1. A Storm Water Quality Management Plan shall be approved by the Building and Safety —/—/— Official and the City of Rancho Cucamonga's "Memorandum of Storm Water Quality Management Plan" shall be recorded prior to the issuance of a Grading Permit 2. The Water Quality Management Plan shall include a copy of the project Conditions of —/—/— Approval. THE APPLICANT SHALL CONTACT THE ENGINEERING SERVICES DEPARTMENT, (909) 477-2740, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: None. APPLICANT SHALL CONTACT THE POLICE DEPARTMENT, (909) 477-2800, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: K. Security Hardware 1. A secondary locking device shall be installed on all sliding glass doors. —/—/- 2. One-inch single cylinder dead bolts shall be installed on all entrance doors. If windows are —/—/— within 40 inches of any locking device, tempered glass or a double cylinder dead bolt shall be used. 3. All garage or rolling doors shall have slide bolts or some type of secondary locking devices. —/—/— L. Windows 1. All sliding glass windows shall have secondary locking devices and should not be able to be —/—/— lifted from frame or track in any manner. M. Building Numbering 1. Numbers and the backgrounds shall be of contrasting color and shall be reflective for —/—/— nighttime visibility. N. Alarm Systems 1. Install a burglar alarm system and a panic alarm if needed. Instructing management and —/—/— employees on the operation of the alarm system will reduce the amount of false alarms and in turn save dollars and lives. 2. Alarm companies shall be provided with the 24-hour Sheriffs dispatch number: —/—/— (909) 941-1488. APPLICANT SHALL CONTACT THE FIRE SAFETY DEPARTMENT, FIRE CONSTRUCTION SERVICES AT, (909) 477-2770, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: The project must comply in design and constructed in accordance with the 2010 California Building and Fire Codes, the RCFPD Ordinance FD50 and the RCFPD Standards. The RCFPD ordinance, procedures & standards which are referenced in this document can be access on the web at www.citvofrc.us. O. Fire Conditions for Single-Family Tracts/Very High Fire Hazard Severity Zone FSC-1 Public and Private Water Supply 1. Design guidelines for Fire Hydrants: The following provides design guidelines for the spacing and location of fire hydrants: — 9 Project No. DRC2013-00018 Completion Date a. For single-family residential projects in the designated Hazardous Fire Area, the fire hydrant design & installation shall be in accordance to RCFPD Policies and Standards. b. If any portion of a facility or building is located more than 150 feet from a public fire hydrant measured on an approved route around the exterior of the facility or building, additional private or public fire hydrants and mains capable of supplying the required fire flow shall be provided. C. Provide one fire hydrant for each 1000 gpm of required fire flow or fraction thereof. FSC-2 Fire Flow 1. The required fire flow for this project will be determined in gallons per minute at a minimum residual pressure of 20-pounds per square inch. This requirement is made in accordance with Fire Code Appendix B, as adopted by the Fire District Ordinances. The Fire flow has been established in the approved FPP 2. Public fire hydrants located within a 500-foot radius of the proposed project may be used to provide the required fire flow subject to Fire District review and approval. Private fire hydrants on adjacent property shall not be used to provide required fire flow. 3. Fire service plans are required for all projects that must extend the existing water supply to or onto the site. Building Permits will not be issued until fire service plans are approved. On all Site Plans to be submitted for review, show all fire hydrants located within 600-feet of the proposed project site. FCS-3 Fire Access Roadway 1. Public and private roads shall be improved as approved by the fire district in the Fire Protection plan before an occupancy release can be granted by the Fire District FSC-4 Hazardous Fire Area This project is located within the "State Responsibility Area" (SRA), the "Very High Fire Hazard Severity Zone" (VHFHSZ), City of Rancho Cucamonga "Hillside District', and/or within the area identified on the Rancho Cucamonga General Plan, Exhibit V-7 as High Probability-High Consequence for Fire Risk. These locations have been determined to be within the "Hazardous Fire Area" as defined by the Fire District. The Hazardous Fire Area is based on maps produced by the California Department of Forestry as adopted by the RCFPD. 1. Hazard Reduction Plans: The applicant shall prepare a Fire Protection Plan and obtain I /_ approval of the plan by RCFPD. The FPP addresses the following: a. Fire protection water supply b. Fire resistive non-combustible roof assemblies c. Fuel Modification by vegetation management d. Fire District access roadways e. Ignition resistive construction and protection of openings f. Fire sprinkler systems g. Fire flow criteria h. For construction requirements in the "Hazard Fire Area" refer to the current editions of the CBC Chapter 7A, The California Residential Code, the RCFPD Ordinance, and the applicable, standards and policies. 10 Project No. DRC2013-00018 Completion Date 2. The architectural plans for the construction of the buildings must be in accordance with the current editions of the CBC Chapter 7A, The California Residential Code, the RCFPD Ordinance, the applicable standards and policies, the County of San Bernardino's Development Code and the approved Fire Protection Plan. 3. Mobile, stationary, or portable power-operated equipment in the Hazardous Fire Area shall not be used without the Fire Safety Division's written approval. Specific fire protection measures that may be required to mitigate the hazard include, but are not limited to: a. A stand-by water tender, equipped with a pump, fire hose and nozzle. b. Pre-wetting of the site to avoid the production of sparks between blades or tracks and rocks. c. Conducting a fire watch for a minimum of one-hour following the cessation of operations each day. d. For welding, cutting or grinding work, clear away all combustible material from the area around such operation for a minimum distance of 10-feet. A "hot-work" permit must be obtained from Fire Construction Services prior to cutting, welding or grinding work. e. Maintain one serviceable round point shovel with an overall length of not less than forty-six (46) inches and one five (5) gallon backpack water pump-type fire extinguisher fully equipped and ready for use at the immediate area during the operation. FCS-5 Prior to the issuance of a Building Permit the applicant shall record the approved Fire Protection plan with the county's recorded office. FCS-6 Prior to the issuance of any Certificate of Occupancy, the property must be inspected and accepted by the Fire District staff. Schedule the inspection with Fire Construction Services at 909-477-2713. FSC-7 Single-family Residential Sales Model homes require approved Fire District vehicle access and water supply from a public or private water main system before construction. FCS-8 Fire Sprinklers: The Current editions of Rancho Cucamonga Fire District Ordinance, the —/—/— California Residential Code and/or any other applicable standards require an approved automatic fire sprinkler system to be installed in all Buildings with R and U occupancy fire areas. All structures must be equipped with automatic fire sprinklers in accordance with NFPA 13D, 13R or 13. FCS-9 Annexation of the parcel map: Annexation of the parcel into the Community Facilities District#85-1 or#88-1 is required prior to the issuance of grading or Building Permits. FSC-10 Alternate Method Application: Fire Construction Services staff and the Fire Marshal will review all requests for alternate method, when submitted. The request must be submitted on the Fire District "Application for Alternate Method" form along with supporting documents and payment of the review fee. Chronological Summary of RCFPD Standard Conditions PRIOR TO OCCUPANCY OR FINAL INSPECTION–Please complete the following: 1. Hydrant Markers: All fire hydrants shall have a blue reflective pavement marker indicating —/—/— the fire hydrant location on the street or driveway in accordance with the City of Rancho Cucamonga Engineering Standard Plan 134, "Installation of Reflective Hydrant Markers". On private property, the markers shall be installed at the centerline of the fire access road, at each hydrant location. 11 Project No. DRC2013-00018 Completion Date 2. Private Fire Hydrants: For the purpose of final acceptance, a licensed sprinkler contractor, in the presence of Fire Construction Services, shall conduct a test of the most hydraulically remote on-site fire hydrants. The underground fire line contractor, developer, and/or owner are responsible for hiring the company to perform the test. A final test report shall be submitted to Fire Construction Services verifying the fire flow available. The fire flow available must meet or exceed the required fire flow in accordance with the California Fire Code. 3. Fire Sprinkler System: Prior to the issuance of a Certificate of Occupancy, the fire sprinkler system(s) shall be tested and accepted by Fire Construction Services. 4. Fire sprinkler monitoring must be installed tested and final by FCS. 5. Fire Access Roadways: Prior to the issuance of any Certificate of Occupancy, the fire access roadways must be installed in accordance with the approved plans and acceptable to Fire Construction Services. The CC&R's, the reciprocal agreement and/or other approved documents shall be recorded and contain an approved fire access roadway map with provisions that prohibit parking, specify the method of enforcement and identifies who is responsible for the required annual inspections and the maintenance of all required fire access roadways. 6. Address: Prior to the granting of occupancy, single-family dwellings shall post the address with noncombustible 4-inch tall numbers on a contrasting background. The numbers shall be internally or externally illuminated during periods of darkness. The numbers shall be visible from the street. When building setback from the public roadway exceeds 100-feet, additional 4-inch numbers shall be displayed at the property entry. 7. The Fire Protection Plan: The approved plans shall be recorded with the county recorder's office. —— 8. Vegetation Management: The landscaping shall be installed and/or modified in accordance with approved FPP and or the RCFPD Standard. 9. All requirements of the FPP or the RCFPD Standard must be completed before an occupancy release may be granted. 12