Loading...
HomeMy WebLinkAbout13-43 - Resolutions RESOLUTION NO. 13-43 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT MODIFICATION DRC2013-00459, A REQUEST TO AMEND CONDITIONAL USE PERMIT CUP95-11 TO MODIFY AN EXISTING MASTER PLAN TO ALLOW FOR THE CONSTRUCTION OF A 4,994 SQUARE FOOT BUILDING WITHIN AN EXISTING SHOPPING CENTERAT THE NORTHWEST CORNER OF ROCHESTER AVENUE AND FOOTHILL BOULEVARD WITHIN THE COMMUNITY COMMERCIAL (CC) DISTRICT OF THE TERRA VISTA COMMUNITY PLAN, ON PROPERTY LOCATED AT 11884 FOOTHILL BOULEVARD;AND MAKING FINDINGS IN SUPPORT THEREOF—APN: 0227-151-38. A. Recitals. 1. Fountainhead Development filed an application for the issuance of Conditional Use Permit Modification DRC2013-00459, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Conditional Use Permit Modification request is referred to as "the application." 2. On the 23rd day of October 2013, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on the application and concluded said hearing on that date. 3. All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing on October 23, 2013, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a. The project area is located on an 11.18-acre parcel located at 11884 Foothill Boulevard within an existing shopping center within the Community Commercial(CC) District of the Terra Vista Community Plan at the northwest corner of Foothill Boulevard and Rochester Avenue; and b. The subject shopping center currently consists of various businesses including a fast food drive-thru restaurant, a sit-down restaurant, a gas station, a home improvement store,a tire store as well as other auto and commercial retail stores; and C. The property to the north of the subject site contains single-family residences and is within the Low Medium (LM) Residential District within the Terra Vista Community Plan; the property to the south consists of commercial retail buildings and is within the Community Commercial (CC) District within the Terra Vista Community Plan; the propertyto the east contains a retail commercial centerwithin the Community Commercial (CC) District as well as single-family residences within the Low Residential (L) District; and the property to the west is vacant land within the Community Commercial (CC) District; and PLANNING COMMISSION RESOLUTION NO. 13-43 DRC2013-00459— FOUNTAIHEAD DEVELOPMENT October 23, 2013 Page 2 d. The project proposes the development of a .47-acre parcel with a 4,994 square building. The building will include an automotive servicing area that will accommodate a maximum of 8 vehicles, a tire storage room, as well as a sales and waiting area. The dimensions of the building footprint will be approximately 150 feet wide by 36 feet deep; and e. The architecture of the building will generally match the established theme throughout the shopping center and will incorporate stucco coated walls, concrete S-tile roof on the tower at the south end of the building, EI Dorado stone veneer placed on the columns at various locations of the building, a wood decorative awning, clear anodized aluminum storefront ,and metal roll up doors to provide access to the service bays. The building will have a maximum height of 28 feet; and f. The proposal also includes the installation of a detached accessory structure that will be used to house the trash bins as well as used tire storage. The accessory structure will match the material, color, and style of the primary building; and g. Per Section 17.64 of the Development Code, parking is calculated for vehicle service uses at 2.5 spaces for every 1,000 square feet of building area. Therefore, a total of 13 parking spaces are required for this use. Since the project includes a total of 17 parking spaces, the site will contain sufficient parking. Furthermore, although the proposed development will require the removal of 66 parking spaces throughout the shopping center, 936 overall parking spaces will be provided, 174 of which are surplus parking spaces. 3. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing and upon the specific findings of facts set forth in Paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The proposed use is in accord with the General Plan, the objectives of the Development Code, and the purposes of the district in which the site is located. The proposed project is consistent with the objectives of the General Plan, which encourages in-fill commercial development is encouraged. The General Plan states that attention to the design of infill development is essential to ensure that the new development fits in with the established physical context and gains acceptance from the surrounding neighborhoods. This project fits with the established character of the built environment; and b. The proposed use, together with the conditions applicable thereto, will not be detrimental to the public health, safety or welfare, or materially injurious to properties or improvements in the vicinity. The proposed development is compatible with the surrounding shopping center; and C. The proposed use complies with each of the applicable provisions of the Development Code. In addition to the installation of a 4,994 square foot building, the site will contain sufficient landscaping and parking. 4. The Planning Department staff has determined that the project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) and the City's CEQA Guidelines. The project qualifies under the Class 32 exemption under State CEQA Guidelines Section 15332 (In-Fill Development Projects) because as the project is consistent with the applicable General Plan designation and all applicable General Plan policies as well as with applicable zoning designation and regulations, the proposed development occurs within City limits on a project site of PLANNING COMMISSION RESOLUTION NO. 13-43 DRC2013-00459— FOUNTAIHEAD DEVELOPMENT October 23, 2013 Page 3 no more than five acres substantially surrounded by urban uses, the project site has no value as habitat for endangered, rare or threatened species, approval of the project would not result in any significant effects relating to traffic, noise, air quality, orwater quality, and the site can be adequately served by all required utilities and public services. In addition, there is no substantial evidence that the project may have a significant effect on the environment. The Planning Commission has reviewed the Planning Department's determination of exemption, and based on its own independent judgment, concurs in the staffs determination of exemption. 5. Based upon the findings and conclusions set forth in Paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth below and in the Standard Conditions, attached hereto and incorporated herein by this reference. Planning Department 1) Approval is forthe modification of Conditional Use Permit CUP95-11 to allow for the development of a 4,994 square foot building located on a .47-acre site within the existing shopping center at the northwest comer of Foothill Boulevard and Rochester Avenue -APN: 0227-151-38. 2) The design of the proposed building shall be consistent with the plans submitted and reviewed by the Design Review Committee and approved by the Planning Commission. Final design review shall be subject to Planning Manager review and approval at Building Permit plan check review. 3) The tower element shall incorporate concrete tile roof material to match the concrete tile used throughout the shopping center. 4) EI Dorado stone veneer shall be incorporated on the proposed building as shown on the elevations reviewed by the Planning Commission. 5) The wood framing element indicated on the tower feature of the proposed building shall be designed and constructed to match the architecture used on the existing buildings throughout the shopping center. 6) All roof drain downspouts shall be routed through the interior of the building. 7) The color of the metal doors shown on the south and west building elevations shall match the colors.indicated on the building elevations reviewed by the Planning Commission. 8) The interior of the raised roof parapets and cornice shall be painted to match the exterior colors. 9) The proposed trees, shrubs, ground cover, and planters shall be consistent with the Landscape Plan reviewed by the Planning Commission. PLANNING COMMISSION RESOLUTION NO. 13-43 DRC2013-00459 — FOUNTAIHEAD DEVELOPMENT October 23, 2013 Page 4 10) The proposed trash enclosure/tire storage accessory building shall be architecturally compatible with the primary building on this parcel. Final design review shall be subject to Planning Manager review and approval at Building Permit plan check review. 11) The height of any relocated parking lot lights shall remain consistent with the height of the existing parking lot lights. 12) All parking lot striping shall be double striped to match the existing parking lot striping. 13) All proposed retaining walls shall be stucco coated with texture and paint to match the primary building on this parcel. 14) Any new ground-mounted equipment and utility boxes, including transformers, back-flow devices, etc., shall be screened by a minimum of two rows of shrubs spaced 18-inches on center. This equipment shall be painted forest green. 15) Any new Double Detector Checks (DDC) and Fire Department Connections (FDC)that are required and/or proposed shall be screened behind a 4-foot high block wall. These walls shall have a decorative finish to match the architecture of the primary building on this parcel. 16) All proposed signs shall comply with Uniform Sign Program (USP) #124. 17) All signs shall require review and approval of a Sign Permit application by the Planning Manager prior to installation. 18) Approval of this request shall not waive compliance with anysections of the Development Code, State Fire Marshal's regulations Uniform Building Code, or any other City ordinances. 19) Any revision to the approved plans shall require review and approval by the Planning Manager. Engineering Services Department 1) The final parcel map shall be submitted for review and approval. Plan check fees will be required and determined at.the time of submittal. 2) Prior to the issuance of Building Permits, a Diversion Deposit and related administrative fees shall be paid for the Construction and Demolition Diversion Program. The deposit is fully refundable if at least 50 percent of all wastes generated during construction and demolition are diverted from landfills and appropriate documentation is provided to the City. Form CD-1 shall be submitted to the Engineering Services Department when the first Building Permit application is submitted to Building and Safety Services Department. Form CD-2 shall be PLANNING COMMISSION RESOLUTION NO. 13-43 DRC2013-00459 — FOUNTAIHEAD DEVELOPMENT October 23, 2013 Page 5 submitted to the Engineering Services Department within 60 days following the completion of the construction and/or demolition project. 3) Reciprocal access easements shall be provided ensuring access to all parcels by Covenants, Conditions, and Restrictions (CC & Rs) or by deeds and shall be recorded concurrently with the map. 4) Reciprocal parking agreements for all parcels and maintenance agreements ensuring joint maintenance of all common roads, drives or parking areas shall be provided by CC & Rs or deeds and shall be recorded prior to, or concurrent with the final parcel map. Grading 1) The applicant shall prepare or amend the existing CC&Rs as needed to clarify how maintenance responsibilities will be shared between the newly created parcels and the remaining existing parcels of Parcel Map (SUBTPM19433) prior to approval of the Parcel Map. The Grading and Drainage Plan and the CC&Rs shall address shared access to Foothill Boulevard, private storm drains, surface drainage and maintenance of common areas, including landscaping within public rights-of-way and Best Management Practices identified in the Water Quality Management Plan (WQMP). WATER QUALITY MANAGEMENT PLAN 1) A Storm Water Quality Management Plan shall be approved by the Building and Safety Official and the City of Rancho Cucamonga's "Memorandum of Storm Water Quality Management Plan" shall be recorded prior to the issuance of a Building Permit. 2) The WQMP submitted with the application does not follow current WQMP templates/guidance and regulations set forth by the Santa Ana Regional Water Quality Control board (RWQCB). Access the following website for an updated San Bernardino County Water Quality Management Plan (WQMP)for New Development and Redevelopment Projects: http://www.swrcb.ca.gov/rwgcb8/html/sb wgmp.html. 3) This site provides Guidance and Templates that can be filled out electronically and printed. Adhere to these guidelines and use the templates provided. Also, include the BMPs identified in the plan on the Grading Plans when submitted for plan check. 4) The Water Quality Management Plan (WQMP) prepared by Fitzmaurice Consulting-Civil Engineering, dated July 24, 2013, is deemed "Incomplete." The following comments are required to be completed prior to the issuance of a Building Permit: PLANNING COMMISSION RESOLUTION NO. 13-43 DRC2013-00459 — FOUNTAIHEAD DEVELOPMENT October 23, 2013 Page 6 Section Page Comments This document shall be completed using the current adopted San Bernardino County model template for the Water Quality Management Plan. 6. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 23RD DAY OF OCTOBER 2013. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: �� ,v rances owdyshell, Chairman ATTEST: 0'-� Q -��A A Zc-- Candyce ett, ecretary I, Candyce Burnett, Secretary of the Planning Commission for the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 23rd day of October 2013, by the following vote-to-wit: AYES: COMMISSIONERS: FLETCHER, HOWDYSHELL, MUNOZ, OAXACA NOES: COMMISSIONERS: NONE ABSENT: COMMISSIONERS: WIMBERLY ABSTAIN: COMMISSIONERS: NONE COMMUNITY DEVELOPMENT DEPARTMENT STANDARD CONDITIONS PROJECT M DRC2013-00459 SUBJECT: CONDITIONAL USE PERMIT MODIFICATION APPLICANT: FOUNTAINHEAD DEVELOPMENT NORTHWEST CORNER OF ROCHESTER AVENUE AND FOOTHILL BOULEVARD — LOCATION: APN: 0227-151-38. ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT. APPLICANT SHALL CONTACT THE PLANNING DEPARTMENT, (909) 477-2750, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: A. General Requirements Completion Date 1. The applicant shall agree to defend at his sole expense any action brought against the City, its agents, officers, or employees, because of the issuance of such approval, or in the alternative, to relinquish such approval. The applicant shall reimburse the City, its agents, officers, or employees, for any Court costs and attorney's fees which the City, its agents, officers, or employees may be required by a court to pay as a result of such action. The City may, at its sole discretion, participate at its own expense in the defense of any such action but such participation shall not relieve applicant of his obligations under this condition. 2. Copies of the signed Planning Commission Resolution of Approval No. 13-43 and Standard Conditions shall be included on the plans (full size). The sheet(s) are for information only to all parties involved in the construction/grading activities and are not required to be wet sealed/stamped by a licensed Engineer/Architect. 3. The applicant shall be required to pay any applicable Fish and Game fees as shown below. The project planner will confirm which fees apply to this project. All checks are to be made payable to the Clerk of the Board Supervisors and submitted to the Planning Commission Secretary prior to the Planning Commission or Planning Manager hearing. a) Notice of Exemption -$50 X B. Time Limits 1. Any approval shall expire if Building Permits are not issued or approved use has not commenced within 5 years from the date of approval or a time extension has been granted. 1 Project No. DRC2013-00459 Completion Date C. Site Development 1. The site shall be developed and maintained in accordance with the approved plans which include Site Plans, architectural elevations, exterior materials and colors, landscaping, sign program, and grading on file in the Planning Department, the conditions contained herein, the Development Code regulations, and the Terra Vista Community Plan. 2. Prior to any use of the project site or business activity being commenced thereon, all Conditions of Approval shall be completed to the satisfaction of the Planning Manager. 3. Occupancy of the facilities shall not commence until such time as all California Building Code and State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety Services Department to show compliance. The buildings shall be inspected for compliance and final acceptance granted prior to occupancy. 4. Revised Site Plans and building elevations incorporating all Conditions of Approval shall be submitted for Planning Manager review and approval prior to the issuance of Building Permits. 5. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for consistency prior to issuance of any permits (such as grading, tree removal, encroachment, building, etc.) or prior to final map approval in the case of a custom lot subdivision, or approved use has commenced, whichever comes first. 6. Approval of this request shall not waive compliance with all sections of the Development Code, all other applicable City Ordinances, and applicable Community, Specific Plans and/or Master Plans in effect at the time of Building Permit issuance. 7. A detailed on-site lighting plan, including a photometric diagram, shall be reviewed and approved by the Planning Manager and Police Department(477-2800) prior to the issuance of Building Permits. Such plan shall indicate style, illumination, location, height, and method of shielding so as not to adversely affect adjacent properties. 8. Trash receptacle(s) are required and shall meet City standards. The final design, locations, and the number of trash receptacles shall be subject to Planning Manager review and approval prior to the issuance of Building Permits. 9. All ground-mounted utility appurtenances such as transformers, AC condensers, etc., shall be located out of public view and adequately screened through the use of a combination of concrete or masonry walls, berming, and/or landscaping to the satisfaction of the Planning Manager. For single-family residential developments, transformers shall be placed in underground vaults. 10. All building numbers and individual units shall be identified in a clear and concise manner, including proper illumination and in conformance with Building and Safety Services Department standards, the Municipal Code and the Rancho Cucamonga Fire Department (RCFD) Standards. 11. All parkways, open areas, and landscaping shall be permanently maintained by the property owner, homeowners' association, or other means acceptable to the City. Proof of this landscape maintenance shall be submitted for Planning Manager and Engineering Services Department review and approved prior to the issuance of Building Permits. D. SHOPPING CENTERS 1. Graffiti shall be removed within 72 hours. 2 Project No. SUBTPM19433 Completion Date D. SHOPPING CENTERS 1. Graffiti shall be removed within 72 hours. 2. The entire site shall be kept free from trash and debris at all times and in no event shall trash and debris remain for more than 24 hours. 3. Signs shall be conveniently posted for"no overnight parking". 4. All operations and businesses shall be conducted to comply with the following standards which shall be incorporated into the lease agreements for all tenants: a. Noise Level - All commercial activities shall not create any noise that would exceed an exterior noise level of 65 dB during the hours of 10 p.m. until 7 a.m. and 70 dB during the hours of 7 a.m. until 10 p.m. b. Loading and Unloading - No person shall cause the loading, unloading, opening, closing, or other handling of boxes, crates, containers, building materials, garbage cans, or other similar objects between the hours of 10 p.m. and 7 a.m. unless otherwise specified herein, in a manner which would cause a noise disturbance to a residential area. 5. The lighting fixture design shall compliment the architectural program. It shall include the plaza area lighting fixtures, building lighting fixtures (exterior), and parking lot lighting fixtures. E. Building Design 1. All roof appurtenances, including air conditioners and other roof mounted equipment and/or projections shall be screened from all sides and the sound shall be buffered from adjacent properties and streets as required by the Planning Department. Such screening shall be architecturally integrated with the building design and constructed to the satisfaction of the Planning Manager. Any roof-mounted mechanical equipment and/or ductwork, that projects vertically more than 18 inches above the roof or roof parapet, shall be screened by an architecturally designed enclosure which exhibits a permanent nature with the building design and is detailed consistent with the building. Any roof-mounted mechanical equipment and/or ductwork, that projects vertically less than 18 inches above the roof or roof parapet shall be painted consistent with the color scheme of the building. Details shall be included in building plans. 2. For commercial and industrial projects, paint roll-up doors and service doors to match main building colors. F. Parking and Vehicular Access (indicate details on building plans) 1. All parking spaces shall be 9 feet wide by 17 feet long with a required 1-foot overhang (e.g., over a curb stop). 2. All parking lot landscape islands shall have a minimum outside dimension of 6 feet. 3. All parking spaces shall be double striped per City standards and all driveway aisles, entrances, and exits shall be striped per City standards. 3 Project No. DRC2013-00459 Completion Date plans. The location of those trees to be preserved in place and new locations for transplanted trees shall be shown on the detailed landscape plans. The applicant shall follow all of the arborist's recommendations regarding preservation, transplanting, and trimming methods. 3. A minimum of 20 percent of trees planted within industrial projects, and a minimum of 30 percent within commercial and office projects, shall be specimen size trees -24-inch box or larger. 4. Within parking lots, trees shall be planted at a rate of one 15-gallon tree for every three parking stalls. 5. Trees shall be planted in areas of public view adjacent to and along structures at a rate of one tree per 30 linear feet of building. 6. The final design of the perimeter parkways, walls, landscaping, and sidewalks shall be included in the required landscape plans and shall be subject to Planning Manager review and approval and coordinated for consistency with any parkway landscaping plan which may be required by the Engineering Services Department. 7. Landscaping and irrigation shall be designed to conserve water through the principles of water efficient landscaping per Development Code Chapter 17.82. H. Signs 1. The signs indicated on the submitted plans are conceptual only and not a part of this approval. Any signs proposed for this development shall comply with Uniform Sign Program #124 and shall require separate application and approval by the Planning Department prior to installation of any signs. I. Building and Safety Industrial and Commercial Standard Conditions 1. Submit five complete sets of plans including the following: a. Site/Plot Plan; b. Foundation Plan; C. Floor Plan; d. Ceiling and Roof Framing Plan; e. Electrical Plans (2 sets, detached) including the size of the main switch, number and size of service entrance conductors, panel schedules, and single line diagrams; f. Plumbing and Sewer Plans, including isometrics, underground diagrams, water and waste diagram, sewer or septic system location, fixture units, gas piping, and heating and air conditioning; and g. Planning Department Project Number (DRC2013-00459) clearly identified on the outside of all plans 2. Submit two sets of structural calculations, two sets of energy conservation calculations, and a soils report. Architect's/Engineer's stamp and "wet" signature are required prior to plan check submittal. 3. Contractors must show proof of State and City licenses and Workers' Compensation coverage to the City prior to permit issuance. 4. Separate permits are required for fencing and/or walls. 4 Project No. DRC2013-00459 Completion Date 5. Business shall not open for operation prior to posting the Certificate of Occupancy issued by the Building and Safety Services Department. 6. Developers wishing to participate in the Community Energy Efficiency Program (CEEP) can contact the Building and Safety Services Department staff for information and submittal requirements. Site Development 1. Plans shall be submitted for plan check and approved prior to construction. All plans shall be marked with the project file number (DRC2013-00459). The applicant shall comply with the latest adopted California Codes, and all other applicable codes, ordinances, and regulations in effect at the time of permit application. Contact the Building and Safety Services Department for availability of the Code Adoption Ordinance and applicable handouts. 2. Prior to issuance of Building Permits for a new residential project or major addition, the applicant shall pay development fees at the established rate. Such fees may include, but are not limited to: Permit and Plan Check Fees, Construction and Demolition Diversion Program deposit and fees and School Fees. The applicant shall provide a copy of the School Fees receipt to the Building and Safety Services Department prior to permit issuance. 3. Prior to issuance of permit issuance for a new residential project or major addition, the applicant shall pay development fees at the established rate. Such fees may include, but are not limited to: City Beautification Fee, Park Fee, Drainage Fee, and Transportation Development Fee. 4. Prior to issuance of Building Permits for a new commercial or industrial development project or major addition, the applicant shall pay development fees at the established rate. Such fees may include but are not limited to: City Beautification Fee, Park Fee, Drainage Fee, Transportation Development Fee, Permit and Plan Check Fees, Construction and Demolition Diversion Program deposit and fees and School Fees. The applicant shall provide a copy of the school fees receipt to the Building and Safety Services Department prior to permits issuance. 5. Street addresses shall be provided by the Building and Safety Official after tract/parcel map recordation and prior to issuance of Building Permits. 6. For projects using septic tank facilities, shall be submitted to the Building and Safety Official for review and approval prior to the issuance of Septic Tank Permits, and prior to the issuance of Building Permits. 7. Construction activity shall not occur between the hours of 8:00 p.m. and 6:30 a.m. Monday through Saturday, with no construction on Sunday or holidays. 8. Construct trash enclosure(s) per City Standard (available at the Planning Department public counter). 9. All commercial/public/multi-family development swimming pool plans shall be submitted to the County of San Bernardino's Environmental Health Services Department for review and approval prior to approval from the City of Rancho Cucamonga. 10. The following is required for side yard use for increase in allowable area: a. Provide a reduced Site Plan (8 1/2-inches by 11 inches), which indicates the non- buildable easement. 5 Project No. DRC2013-00459 Completion Date b. Recorded "Covenant and Agreement for the Maintenance of a Non-Buildable Easement,"which is signed by the appropriate property owner(s). New Structures 1. Provide compliance with the California Building Code (CBC) for property line clearances considering use, area, and fire-resistiveness. 2. Provide compliance with the California Building Code for required occupancy separations. 3. Roofing material shall be installed per the manufacturer's "high wind" instructions. 4. Plans for food preparation areas shall be approved by County of San Bernardino Environmental Health Services prior to issuance of Building Permits. 5. Provide draft stops in attic areas in accordance with CBC Section 1505. 6. Roofing materials shall be Class"A." 7. Exterior walls shall be constructed of the required fire rating in accordance with CBC . 8. Openings in exterior walls shall be protected in accordance with CBC. 9. Walls and floors separating dwelling units in the same building shall be in accordance with the CBC. 10. Provide smoke and heat venting in accordance with CBC. 11. Upon plan check submittal, additional requirements may be needed. J. Grading 1. Grading of the subject property shall be in accordance with current adopted California Building Code, City Grading Standards, and accepted grading practices. The grading and drainage plan(s) shall be in substantial conformance with the approved conceptual grading and drainage plan. 2. A soils report shall be prepared by a qualified engineer licensed by the State of California to perform such work. Two copies will be provided at grading and drainage plan submittal for review. Plans shall implement design recommendations per said report. 3. The final Grading and Drainage Plan, appropriate certifications and compaction reports shall be completed, submitted, and approved by the Building and Safety Official prior to the issuance of Building Permits. 4. A separate Grading and Plan check submittal is required for all new construction projects and for existing buildings where improvements being proposed will generate 50 cubic yards or more of combined cut and fill. The Grading and Drainage Plan shall be prepared, stamped, and wet signed by a California licensed Civil Engineer. 5. If human remains are discovered on-site before or during grading, no further disturbance shall occur until the County Coroner has made a determination of origin and disposition pursuant to Public Resources Code Section 5097.98 and California Health and Safety Code Section 7050.5. 6 Project No. DRC2013-00459 Completion Date 6. The applicant shall comply with the City of Rancho Cucamonga Dust Control Measures and —/—/— place a dust control sign on the project site prior to the issuance of a Grading Permit. 7. A drainage study showing a 100-year, AMC 3 design storm event for on-site drainage shall —/—/— be prepared and submitted to the Building and Safety Official for review and approval for on-site storm water drainage prior to issuance of a Grading Permit. All reports shall be wet signed and sealed by the Engineer of Record. 8. It shall be the responsibility of the applicant to acquire any required off-site drainage easements prior to the issuance of a Grading Permit, 9. Private sewer, water, and storm drain improvements will be designed per the latest adopted —/—/— California Plumbing Code. 10. The maximum parking stall gradient is 5 percent. Accessibility parking stall grades shall be —/—/— constructed per the current adopted California Building Code. 11. This project shall comply with the accessibility requirements of the current adopted —/—/— California Building Code. 12. Prior to the issuance of the Certificate of Occupancy the engineer of record shall certify the —/—/— functionality of the storm water quality management plan (WQMP) best management practices (BMP)devices. K. Water Quality Management Plan 1. A Storm Water Quality Management Plan shall be approved by the Building and Safety —/—/— Official and the City of Rancho Cucamonga's "Memorandum of Storm Water Quality Management Plan" shall be recorded prior to the issuance of a Grading Permit 2. The Water Quality Management Plan shall include a copy of the project Conditions of —/—/— Approval. L. Commercial Fire Standard Conditions FSC -1 Public and Private Water Supply 1. Design guidelines for Fire Hydrants: Reference the RCFPD Standard 5-10. —/—/— FSC-2 Fire Flow 1. The required fire flow for this project is calculated gallons per minute at a minimum residual —/—/— pressure of 20 pounds per square inch. This requirement is made in accordance with California Fire Code Appendix, as adopted by the Fire District Ordinances. The required minimum fire flow for this project may be reduced by 50 percent when automatic fire sprinklers are installed. 2. Public fire hydrants located within the immediate vicinity of the proposed project may be used to provide the required fire flow subject to Fire District review and approval. Private fire hydrants on adjacent property shall not be used to provide required fire flow. 3. Fire protection water supply plans are required for all projects that must extend the existing —/—/— water supply to or onto the site. Building Permits will not be issued until the fire protection water supply plans are approved. 4. On all Site Plans to be submitted for review, show all fire hydrants located within 600-feet of —/—/— the proposed project site. 7 Project No. DRC2013-00459 Completion Date FSC-3 Prerequisite for submittal of Overhead Automatic Fire Sprinkler Systems —/—/— Prior to submitting plans for an overhead automatic fire sprinkler system, the applicant shall —/—/— submit plans, specifications and calculations for the fire sprinkler system underground supply piping. Approval of the underground supply piping system must be obtained prior to submitting the overhead fire sprinkler system plans. FSC-4 Requirements for Automatic Fire Sprinkler Systems Automatic fire sprinklers shall be installed in buildings as required by the current editions of the —/—/— California Fire Code, the Rancho Cucamonga Fire Protection District Ordinance and/or any other applicable standards that require an approved automatic fire sprinkler system to be installed. FSC-5 Fire Alarm System & Sprinkler Monitoring The current edition California Building/Fire Codes, the RCFPD Ordinance and Fire Alarm —/—/— Standard require most fire sprinkler systems to be monitored by a Central Station sprinkler monitoring system. A manual and or automatic fire alarm system may also be required based on the use and occupancy of the building. Plan check approval and a Building Permit are required prior to the installation of a fire alarm or a sprinkler monitoring system. Plans and specifications shall be submitted to Fire Construction Services in accordance with RCFPD Fire Alarm Standard. Refer to the specified documents for the system requirements. FSC-6 Fire District Site Access: Fire District access roadways include public roads, streets and highways, as well as private roads, drive aisles and/or designated fire lanes. Please reference the RCFPD Fire Department Access Roadways Standard. 1. Location of Access: All portions of the structures 1st story exterior wall shall be located —/—/— within 150-feet of Fire District vehicle access, measured on an approved route around the exterior of the building. Landscaped areas, unpaved changes in elevation, gates and fences are deemed obstructions. 2. Specifications for private Fire District Access roadways per the RCFPD Standards are: —/—/— a. The minimum unobstructed width is 26 feet. b. The maximum inside turn radius shall be 24 feet. c. The minimum outside turn radius shall be 50 feet. d. The minimum radius for cul-de-sacs is 45 feet. e. The minimum vertical clearance is 14 feet, 6 inches. f. At any private entry median, the minimum width of traffic lanes shall be 20 feet on each side. g. The angle of departure and approach shall not exceed 9 degrees or 20 percent. h. The maximum grade of the driving surface shall not exceed 12 percent. i. Support a minimum load of 80,000 pounds gross vehicle weight(GVW). j. Trees and shrubs planted adjacent to the fire lane shall be kept trimmed to a minimum of 14-feet, 6-inches from the ground up. Vegetation shall not be allowed to obstruct Fire Department apparatus. 3. Access Doorways Approved doorways, accessible without the use of a ladder, shall be —/—/— provided as follows: a. In buildings without high-piled storage, access shall be provided in accordance with the current edition of California Building/Fire Codes and/or any other applicable standards. 8 Project No. DRC2013-00459 Completion Date b. In buildings with high-piled storage access doors shall be provided in each 100 lineal feet or major fraction thereof, of the exterior wall that faces the required access roadways. When railways are installed provisions shall be made to maintain Fire District access to all required openings. 4. Access Walkways: Hardscaped access walkways shall be provided from the fire apparatus —/—/— access road to all required building exterior openings. 5. Building Access: Knox boxes for site and building access are required in accordance with —/—/— RCFPD Standard 5-9. 6. Commercial/Industrial Gates: Any gate installed across a Fire Department access road —/—/— shall be in accordance with the Fire District Standard. The following design requirements apply: a. Prior to the fabrication and installation of the gates, plans are required to be submitted to Fire Construction Services (FCS) for approval. Upon the completion of the installation and before placing the gates in service, inspection and final acceptance must be requested from FCS. b. Gates must slide open horizontally or swing inward. c. Gates may be motorized or manual. d. When fully open, the minimum clearance dimension of drive access shall be 20 feet. e. Manual gates must be equipped with a RCFPD lock. The lock must be purchased at the Fire Administration Office. f. Motorized gates must open at the rate of one-foot per second. g. The motorized gate actuation mechanism must be equipped with a manual override device and a fail-safe or battery backup feature to open the gate or release the locking Mechanism in case of power failure or mechanical malfunction. h. Motorized gates shall be equipped with a Knox override key switch. The switch must be installed outside the gate in a visible and unobstructed location. i. For motorized gates, a traffic loop device must be installed to allow exiting from the complex. j. If traffic pre-emption devices (TPD) are to be installed, the device, location and operation must be approved by the Fire Chief prior to installation. Bi-directional or multiple sensors may be required due to complexity of the various entry configurations. 7. Fire Lane Identification: Red curbing and/or signage shall identify the fire lanes. A Site Plan —/—/— illustrating the proposed delineation that meets the minimum Fire District standards shall be included in the architectural plans submitted to the Building and Safety Services Department for approval. 8. Approved Fire Department Access: Any approved mitigation measures must be clearly —/—/— noted on the Site Plan. A copy of the approved Alternative Method application, if applicable, must be reproduced on the architectural plans submitted to B&S for plan review. 9. Roof Access: Must be in accordance with the RCFPD Roof Access Standard 5-6. There —/—/— shall be a means of Fire Department access from the exterior walls of the buildings onto the roofs of all commercial, industrial, and multi-family residential structures more than 10,000 square feet or with roof more than 15 feet in height and less than 75 feet above the level of the fire access road. a. This access must be reachable by the Fire Department aerial ladder. 9 Project No. DRC2013-00459 Completion Date b. A minimum of one ladder point with a fixed ladder shall be provided in buildings with construction features, or high parapets that inhibit roof access. c. The number of ladder points may be required to be increased, depending on the building size and configuration. d. Regardless of the parapet height or construction features the approved ladder point shall be identified in accordance to the roof access standard. e. Where the entire roof access is restricted by high parapet walls or other obstructions, a permanently mounted access ladder is required. f. Multiple access ladders may be required for larger buildings. g. Ladder construction must be in accordance with the RCFPD Roof Access Standard Appendix. h. A Site Plan showing the locations of the roof ladder shall be submitted during plan check. i. Ladder points shall face a fire access roadway(s). FSC-10 Occupancy and Hazard Control Permits Listed are those Fire Code permits commonly associated with the business operations and/or building construction. Plan check submittal is required with the permit application for approval of the permit; field inspection is required prior to permit issuance. General Use Permit shall be required for any activity or operation not specifically described below, which in the judgment of the Fire Chief is likely to produce conditions that may be hazardous to life or property. • Candies and open flames in public assemblies • Compressed Gases • Dry Cleaning Plants • Explosive or Blasting Agents • Repair Garages • Refrigeration Systems • Public Assembly • Tents, Canopies and/or Air Supported Structures • LPG or Gas Fuel Vehicles in Assembly Buildings FSC-12 Hazardous Materials — Submittal to Fire Construction Services. Plans shall be submitted and approved prior to construction of buildings and/or the installation of equipment designed to store, use or dispense hazardous materials in accordance with the current editions of the California Building, Fire, Mechanical, Plumbing, Electrical Codes, RCFPD Ordinances and other implemented and/or adopted standards. FSC -13 Alternate Method Application - Fire Construction Services staff and the Fire Marshal _/_/_ will review all requests for alternate method, when submitted. The request must be submitted on the Fire District "Application for Alternate Method" form along with supporting documents and payment of the review fee. Map Recordation 1. Reciprocal Agreements for Fire Department Emergency Access and Water Supply are required on this project. The project appears to be located on a property that is being subdivided. The reciprocal agreement is required to be recorded between property owners and the Fire District. The recorded agreement shall include a copy of the Site Plan. The Fire Construction Services shall approve the agreement, prior to recordation. The agreement shall be recorded with the County of San Bernardino, Recorder's Office. 10 Project No. DRC2013-00459 Completion Date 2. Reciprocal Access Agreement — Please provide a permanent access agreement between the owners granting irrevocable and a non-exclusive easement, favoring the Fire District to gain access to the subject property. The agreement shall include a statement that no obstruction, gate, fence, building or other structure shall be placed within the dedicated access, without Fire Department approval. The agreement shall have provisions for emergency situations and the assessing of cost recovery to the property by the Fire District. 3. Reciprocal Water Covenant — Please provide a permanent maintenance and service covenant between the owners granting an irrevocable and non-exclusive easement, favoring the Fire District for the purpose of accessing and maintaining the private water mains, valves and fire hydrants (fire protection systems facilities in general). The covenant shall have provisions for emergency situations and the assessing of cost recovery to the property by the Fire District. FSC-15 Annexation of the parcel map: Annexation of the parcel map into the Community Facilities District#85-1 or#88-1 is required prior to the issuance of Grading or Building Permits. Chronological Summary of RCFPD Standard Conditions PRIOR TO ISSUANCE OF BUILDING PERMITS - Please complete the following prior to the issuance of any Building Permits: 1. Private Water Supply (Fire) Systems: The applicant shall submit construction plans, specifications, flow test data and calculations for the private water main system for review and approval by the Fire District. Plans and installation shall comply with Fire District Standards. Approval of the on-site (private) fire underground and water plans is required prior to any Building Permit issuance for any structure on the site. Private on-site combination domestic and fire supply system must be designed in accordance with RCFPD Standards. The Building and Safety Services Department and Fire Construction Services will perform plan checks and inspections. All private on-site fire hydrants shall be installed, flushed and operable prior to delivering any combustible framing materials to the site. Fire construction Services will inspect the installation, witness hydrant flushing and grant a clearance before lumber is dropped. 2. Public Water Supply (Domestic/Fire) Systems: The applicant shall submit a plan showing the locations of all new public fire hydrants for the review and approval by the Fire District and CVWD. On the plan, show all existing fire hydrants within a 600-foot radius of the project. Please reference the RCFPD Water Plan Submittal Procedure Standard. All required public fire hydrants shall be installed, flushed and operable prior to delivering any combustible framing materials to the site. CVWD personnel shall inspect the installation and witness the hydrant flushing. Fire Construction Services shall inspect the site after acceptance of the public water system by CVWD. Fire Construction Services must grant a clearance before lumber is dropped. 3. Construction Access: The access roads must be paved in accordance with all the _/_/_ requirements of the RCFPD Fire Lane Standard. All temporary utilities over access roads must be installed at least 14' 6" above the finished surface of the road. 4. Fire Flow: A current fire flow letter from CVWD must be received. The applicant is _/_!_ responsible for obtaining the fire flow information from CVWD and submitting the letter to Fire Construction Services. 5. Easements and Reciprocal Agreements: All easements and agreements must be recorded with the County of San Bernardino. 11 Project No. DRC2013-00459 Completion Date PRIOR TO THE RELEASE OF TEMPORARY POWER The building construction must be substantially completed in accordance with Fire Construction Services' "Temporary Power Release Checklist and Procedures." PRIOR TO OCCUPANCY OR FINAL INSPECTION— Please complete the following: 1. Hydrant Markers: All fire hydrants shall have a blue reflective pavement marker indicating _/_/_ the fire hydrant location on the street or driveway in accordance with the City of Rancho Cucamonga Engineering Standard Plan 134, "Installation of Reflective Hydrant Markers". On private property, the markers shall be installed at the centerline of the fire access road, at each hydrant location. 2. Private Fire Hydrants: For the purpose of final acceptance, a licensed sprinkler contractor, in the presence of Fire Construction Services, shall conduct a test of the most hydraulically remote on-site fire hydrants. The underground fire line contractor, developer and/or owner are responsible for hiring the company to perform the test. A final test report shall be submitted to Fire Construction Services verifying the fire flow available. The fire flow available must meet or exceed the required fire flow in accordance with the California Fire Code. 3. Fire Sprinkler System: Prior to the issuance of a Certificate of Occupancy, the fire sprinkler system(s) shall be tested and accepted by Fire Construction Services. 4. Fire Sprinkler Monitoring: Prior to the issuance of a Certificate of Occupancy, the fire sprinkler monitoring system must be tested and accepted by Fire Construction Services. The fire sprinkler monitoring system shall be installed, tested and operational immediately following the completion of the fire sprinkler system (subject to the release of power). 5. Fire Suppression Systems and/or other special hazard protection systems shall be inspected, tested and accepted by Fire Construction Services before occupancy is granted and/or equipment is placed in service. 6. Fire Alarm System: Prior to the issuance of a Certificate of Occupancy, the fire alarm system shall be installed, inspected, tested and accepted by Fire Construction Services. 7. Access Control Gates: Prior to the issuance of a Certificate of Occupancy, vehicular gates must be inspected, tested and accepted in accordance with RCFPD Standards by Fire Construction Services. 8. Fire Access Roadways: Prior to the issuance of any Certificate of Occupancy, the fire access roadways must be installed in accordance with the approved plans and acceptable to Fire Construction Services. The CC&R's, the reciprocal agreement and/or other approved documents shall be recorded and contain an approved fire access roadway map with provisions that prohibit parking, specify the method of enforcement and identifies who is responsible for the required annual inspections and the maintenance of all required fire access roadways. 9. Address: Must be in accordance with the RCFPD Standard 5-7, 5-8 and/or 5-5. Prior to the issuance of a Certificate of Occupancy, commercial/industrial and multi-family buildings shall post the address in accordance to the appropriate RCFPD addressing Standard. 10. Hazardous Materials: The applicant must obtain inspection and acceptance by Fire Construction Services. 12 Project No. DRC2013-00459 Completion Date 11. Confidential Business Occupancy Information: The applicant shall complete the Rancho —/—I— Cucamonga Fire District "Confidential Business Occupancy Information" form. This form provides contact information for Fire District use in the event of an emergency at the subject building or property. This form must be presented to the Fire Construction Services Inspector. 12. Mapping Site Plan: Must be in accordance with the RCFPD Standard 5-11. Prior to the —/—I— issuance of a Certificate of Occupancy, a 8 1/2-inch by 11-inch or 11-inch by 17-inch Site Plan of the site in accordance with RCFPD Standard shall be revised by the applicant to reflect the actual location of all devices and building features as required in the standard. The Site Plan must be reviewed and accepted by the Fire Inspector. THE APPLICANT SHALL CONTACT THE ENGINEERING SERVICES DEPARTMENT, (909) 477-2740, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: M. Dedication and Vehicular Access 1. Reciprocal access easements shall be provided ensuring access to all parcels by CCBRs or —/—/— by deeds and shall be recorded concurrently with the map or prior to the issuance of Building Permits, where no map is involved. 2. Reciprocal parking agreements for all parcels and maintenance agreements ensuring joint —/—/— maintenance of all common roads, drives, or parking areas shall be provided by CC & R's or deeds and shall be recorded prior to, or concurrent with, the final parcel map. N. Street Improvements 1. Pursuant to Municipal Code Section 16.37.010, no person shall make connections from a —/—/— source of energy, fuel or power to any building or structure which is regulated by technical codes and for which a permit is required unless, in addition to any and all other codes, regulations and ordinances, all improvements required by these conditions of development approval have been completed and accepted by the City Council, except: that in developments containing more than one building, structure or unit, the development may have energy connections made in equal proportion to the percentage of completion of all improvements required by these conditions of development approval, as determined by the City Engineer, provided that reasonable, safe and maintainable access to the property exists. In no case shall more than 95 percent of the buildings, structures or units be connected to energy sources prior to completion and acceptance of all improvements required by these conditions of development approval. O. Utilities 1. Provide separate utility services to each parcel including sanitary sewerage system, water, —/—/— gas, electric power, telephone, and cable TV(all underground) in accordance with the Utility Standards. Easements shall be provided as required. 2. The developer shall be responsible for the relocation of existing utilities as necessary. —/—/- 3. Water and sewer plans shall be designed and constructed to meet the requirements of the —/—/— Cucamonga Valley Water District(CVWD), Rancho Cucamonga Fire Protection District, and the Environmental Health Department of the County of San Bernardino. A letter of compliance from the CVWD is required prior to final map approval or issuance of permits, whichever occurs first. Such letter must have been issued by the water district within 90 days prior to final map approval in the case of subdivision or prior to the issuance of permits in the case of all other residential projects. 13 Project No. DRC2013-00459 Completion Date 4. Approvals have not been secured from all utilities and other interested agencies involved. —/—/— Approval of the final parcel map will be subject to any requirements that may be received from them. P. General Requirements and Approvals 1. Prior to the issuance of Building Permits, a Diversion Deposit and related administrative —/—/— fees shall be paid for the Construction and Demolition Diversion Program. The deposit is fully refundable if at least 50 percent of all wastes generated during construction and demolition are diverted from landfills, and appropriate documentation is provided to the City. Form CD-1 shall be submitted to the Engineering Services Department when the first Building Permit application is submitted to the Building and Safety Services Department. Form CD-2 shall be submitted to the Engineering Services Department within 60 days following the completion of the construction and/or demolition project. 14