HomeMy WebLinkAbout2020-03-11 - Supplementals BCity of Rancho Cucamonga
STEP-THRU BARRIER
REPLACEMENTS
Gianfranco Laurie, Senior Civil Engineer
Engineering Services Department
March 11, 2020
f wi D Z
Vicinity Map
e�
Gte
Alin LBnN wm s, ■
\��lv Qj aveland Y
• �♦Ass ■■■■ ■t■■■■.■."Jo ■■■a■■
C�.r v'
w Blvd — Bwd Foomdl Blvd
••f ■ IMBneho
► ■ (aeamonga _
• r
■ ■ ■
• WM ■
• Culmonge ■
■ ■
♦ ■ ■
Et,.anda
■ •,■
Faomiu Blvd
Ne,ser
s(-if, CITY OF RANCHO CUCAMONGA
r�
Bike Path Step-Thru
Standard Drawings
PVC TRAIL FENCE END POST
PERSTD. TING. 1010
7.5' MIL
S' MAX
1• CHAMFER AT 45^
S' X S'CLEAR PIE POST
TREATED WfTH CHROMATED
COPPER ARSENATE PER MW 2.2
(GREEN9OOK) SET IN CONCRETE
FINISH GRADE
CONCRETE FOOTING
CUSS 5MCG250D
STEP THROUGH
IrMN.
1.5'MIN.
STEP THROUGH
PVC TRAIL FENCE END POST
PER STD OAG. 1010
S' X &' CIfM FINE POST
TREATED NTH CHROMATED
COPPER ARSENATE PER 2042.2
(GREENSOON) SET IN CONCRETE
FINISH GRADE
CONCRETE FOOIRIG
CLASS 500.c25C0
Bike Path Barrier
Bollards can be used to prevent cars or motorcycles from entering a bike path, as well as to slow cyclists down
when approaching an intersection. Bollards should be installed as shown below.
I" GHANI�ER,
YJ�+u•f w�D �s15 �z
�IA1151� I GiT I1V '�ZUAV
G2h9� VF -?AVw, 5vwm
PCL-46I.,rrtAIt
it GUT �l h-G. COW
'fLir-4
Modified Bike Path Barrier
M6
Modified Bike Path Barrier
Recommendation
• Staff is seeking design feedback from the Trails
Advisory Committee on the planned modifications
to the Bike Path Barrier design standard.
Questions?
City of Rancho Cucamonga
PACIFIC ELECTRIC TRAIL
DRAINAGE IMPROVEMENTS
Gianfranco Laurie, Senior Civil Engineer
Engineering Services Department
March 11, 2020
T� D 3
Vicinity Map
V� y
_ I
u•".F�� ���T�'�/�`Ir1�64�/f! ��FFIFLJiJ//�FJ •T!/I/.'�L l/L.:J� • /l �
r� CITY OF RANCHO CUCAMONGA
r�
r�r CITY OF RANCHO CUCAMONGA
r�-
Improvement Plan
pvc
FENCE
TOP OF SLOPE
(TYP)
PATHWAY
8 1 LIGHT
4
INVERT ELEVATION \J FEN
484.0 APPROX. 2
• 487.43
CONL77l7E WiYK
/ . 488.16
J • 489.08 / • 490.24
487.
487.94
489.19
487
487
O
-- ,
` Y 487. 88.
488.7
/Y
C\ 489.1
/ 49i'
0
487.7 .2 •487t Y - — /
_488.5
\ I
•4� 8
24"S7U a 490.8 a
r
z
gWi�Gm .
—• •-sss7e•1�—GQEL:•Gt/R71..
LODECOMPOSED GRANITE
PAVING
--_
— FIBEIZ—OP cS
� ---
—
—
--cO--NS---u--—O—------
—LOCAIDt
--_
S—T—AZ--IO--Y--tN--EI
____—
_
--
CORRUGATED 17M — — —_
PIPE RISER- — ��
CONCRETE APRON-(4A9} _ _ �—
— —
—'-- �� �.�_�
__~�_�—_ _ _ — — —
— —
T 24" DIAMETER CORRUGATED METAL PIPE.
PIPE IS PARTIALLY FILLED WITH
_— — — — —
——
"
DIRT/DEBRIS AND COBBLES
Questions?