Loading...
HomeMy WebLinkAbout1545-S GENERAL NOTES * - IF X = 1 USE THESEDIMENSIONS O 3' "LI 1 . Traffic signal and highway safety lighting systems per CALTRANS Standard Plans CASE 1 and Standard specifications dated July 1992, as shown on the plans and in the ° ° E.C.R Special Provisions. ° ° z _-_ CROSSWALK CAB. O CL DOUBLE YELLOW STRIPE STRIPE , 2. Traffic signs, stripes and legends per CALTRANS Traffic Sign Specifications, Traffic F "P» CAB. 10 OR MEDIAN CURB FACE OR Manual, Maintenance Manual, and Standard Specifications. Conform pavement e w �`.� LIMIT LINE 0 legends to city stencils. Reflectorize all signs, stripes and legends. 2'* 3. Pavement markers and painting procedures for striping per Standard Specifications SIDEWALK ° o4 Er Er for Public Works Construction, latest edition. SIDEWALK ° ° ° •, ° f G 10„ 4. Locate all substructures prior to construction. Hand dig foundations until clear of REFER TO PLAN FOR REMAINING LOOPS 5'* O obstructions. Coordinate pole installations with overhead utility or substructure PLAN SECTION 10'* +Z O owners. Phone Underground Service Alert and concerned utility companies 48 hours prior to construction. Location of utilities and substructures have been shown from a search of available records. The Contractor shall conduct his operation in such a manner as to protect not only the utilities and substructures LEFT TURN LANE 3'* shown, but other utilities or substructures that are not shown on these plans. U 8" WHITE TURNING LANE LINE C6 5. Obtain approval for exact equipment, crosswalk and limit line locations prior to 2, CASE 2 X-6' final placement. Perform preliminary striping layout prior to loop detector layout. ° 2 POLE LOCATION CODE 6. Loop detectors shall be 6 foot by 6 foot, except as noted. Center loops in the M ° ° Z - travelled portion of the lane, except as shown. O Q " �' _� X 10' 6, (EXACT LOCATION BY ENGINEER IN THE FIELD)ID 7 ashicle shown�lcations shall be 12", pullboxes No. 5 and conduit 2" rigid metal except P" CAB. CAB. ° 8. Electrical services shall be 120volt/240volt. Provide circuit breakers for signals -*T (oSIDEW D D ° DrTT 2r g ne 50 amp), illuminated signs (one 15 amp), and safety lighting (one 30 amp SIDEWALKper 1200 watts or portions thereof). Coordinate service detail and scheduling well X-6' In advance of need. See service wiring detail this sheet. 10" INSIDE THRU LANE 2 9. The CONDUCTOR SCHEDULE is furnished as an installation guideline only. It shall PIAN SECTION 4" LANE LINE OR 8" TURNING LANE UNE be the Contractor's responsibility to provide the correct conductors required for 3' the intended operation. CURB " CASE 3 EXIST. c & G 1 o s "P" CAB. p 1-- 7 S t"P" 3„ ° o w � z a � � CAB. ��� � 8" U C — 6" LC 2 ° SIDEWALK OUTSIDE THRU LANE I „ ° b I I4 D ° UTILITY COMPANIES TELE. NOS. ° D D ° V VARIES f�I5 1 , - -- ° 10" ALL DIMENSIONS TO OF STRIPE ELECTRICITY - SOUTHERN CALIFORNIA EDISON COMPANY (909) 947-8269 PIAN SECTION GAS - SOUTHERN CALIFORNIA GAS COMPANY (800) 422-4133 PHONE - GENERAL TELEPHONE COMPANY (909) 608-1230 - PACIFIC TELEPHONE COMPANY (800) 422-4133 WATER - CUCAMONGA COUNTY WATER DISTRICT (909) 987-2591 TYPE " P" CABINETFOU NDATION AN D LOOP DETECTOR PLACEMENT SEWER - CUCAMONGA COUNTY WATER DISTRICT (909) 987-2591 UNDERGROUND SERVICE ALERT 800 422-4133 I . I . S . N . S . LEGEND DETAIL c ) PAD DETAIL REFER TO PLAN FOR DISTANCE TO ADVANCE DETECTORS N INDEX OF SHEETS 1 OF 2 TITLE SHEET 2 OF 2 TRAFFIC SIGNAL PLAN NEMA BASE LINE ROAD Milliken Avenue and Church Street ENCLOSURE 1.5" C. THROUGH CABINET WALL > it N66 HALF NEMA V1SZA BLOCK 12 PAIR ENCLOSURE ZERRA TERMINAL BY ww w w PHONE CO. CABINET w U-1 w w Q Q z 9� CHURCH ST. QROFESS/ �y CHURCH ST. ���- S. E�sF y III LI LUNo. 13493 CFNl C'Po * Exp. 3-31-97 2" C. W/PULL ROPE TO TELEPHONE FR j /BOUL qr C/VI`�SERVICE POINT IF NOTED ON PLAN. � > S�RE� F OF2" C. W/INTERCONNECT CABLE TO INTERSECTION PULLBOX IF NOTED ON PLAN. FOOTHILL 6 6 z Q w NO. DESCRIPTION OF REVISION DATE CITY ACCOM Q1 — INSTALL SURFACE MOUNT WEATHERPROOF NEMA ENCLOSURE ON = U SIDE OF THE CONTROLLER CABINET FOR INTERCONNECT ACCESS C�V� w z w � � ¢o ENCLOSURE DIMENSION SHALL BE 12"x12 x6 WITH 3/4 PLYWOOD C a w N Z CITY OF RANCHO CUCAMONGA BACKBOARD ENCLOSURE FINISH TO MATCH CONTROLLER CABINET. v' Y w 3 ENCLOSURE SHALL BE ALUMINUM WITH HINGED DOOR AND LATCH v � PAINTED TO MATCH THE CONTROLLER CABINET (SEE SPECIAL CE R DRIVE 0o off` TRAFFIC SIGNAL GENERAL INFORMATION AND DETAILS PROVISIONS). �� ARROW ROUTE MILLI KEN AVENUE and CHURCH STREET 0 = TRAFFIC SIGNAL LOCATION APPROVED BY: DATE: -- - CITY ENGINEER R.C.E. DESIG"L•S.E. LAWRENC EISENHART RECOMMENDED 1n� CONSULTING ENGINEER INTERCONNECT TERMINATION DETAIL LOCATION MAP DRAWN 204E Orange Tree Lane. Suite 20E Redlands, California 92374 SH L.S.E. Tel: (909) 793-9242 Fox: (909) 793-4W3i SCALE: V = 0.5 MI. CHECKED DRAWING NO. EN E S. EN T R.C.E. 13493 DATE r /sY5-S EMERGENCY VEHICLE PHASE DIAGRAM CONDUCTOR SCHEDULE PREEMPTION DETECTOR TO SE CORNER OF MOUNTAIN VIEW \ \ & MILLIKEN WITH #5 PB AT MAX. 200' A.W.G ON CENTER. EXTEND I/C TO CONTROLLER RUNS 1 1/2" TO 3/4" ON THE NE CORNER THROUGH NEW CONDUIT ,N � Doi CIRCUIT A QQQQ REDUCCER 1 01 02 03 S2S4 0 1 VEHICLE • 6 3 3 3 3 3 1 3 3 \ Q ASTRO Mini-Brat MOUNT 0 2 VEHICLE 6 3 3 3 3 PELCO AB-121 2 / 0 3 VEHICLE • 3 3 3 3 e 0 OR APPROVED EQUAL ` 0 4 VEHICLE 6 3 3 3 3 3It -- 0 5 VEHICLE • 6 3 --� 0 6 VEHICLE 6 3 3 3 3 3 3 3 MAST-ARM � �No 10 ` ��- 0 7 VEHICLE • 3 3 3 0 8 VEHICLE 6 3 3 3 3 #14 0 2 PEDESTRIAN 4 2 2 2 0 4 PEDESTRIAN 4 2 2 2 2 2 , 05 1 06 11 07 1 08 0 6 PEDESTRIAN 2 2 2 2 2 Is \ \ 0 8 PEDESTRIAN 4 2 2 MAST ARM MOUNTING 0 2 P.P.B. 2 2 1CLAMP FOR \ \ 0 4 P.P.B. 2 1 1 1 1 1 1 1 0 6 P.P.B. 2 2 2 1 \ _ �i NAN°,-Ip1-E MODEL 511 OPTICAL DETECTOR S V pplN�) ,\ •gyp BACK 0 8 P.P.B. 2 1 0 K ' ` 1 S 4 � s 1Y � F� 3 SSW A\ \ Rp � � C P.P.B. COMMON 2 1 1 1 1 1 1 1 p ; 1 OF SPARES 6 3 3 3 3 3 3 3 � ,n TOTAL #14 72 35 28 25 13 29 25 16 H \ 26 •_••+ 12 I.I.S.N.S. - 2 2 2 2 2 2 R �„ C, 410, 212 •� SIGNAL COMMON 2 1 1 1 1 1 1 1 2 2 1 #10 LUMINAIRES 2 2 2 2 2 2 2 v6 '� \ \ �•- TOTAL 10 2 3 3 3 3 3 3 3 5 - Y s V � 2 1 r-�•✓ f 1 PJ DE EC OR 2 5 �n N l X 0 2 DETECTOR 3 5 5 5Y / G (y) � Z 6 5 6 _r•-' O 0 3 DETECTOR 2 2 A or •-� N DLC 0 4 DETECTOR 2 2 2 2 Y 2 C-1 6E r`•.� I,Ii1D Uj TYPE 0 5 DETECTOR 2 <A G ` N . '•_• "C" 0 6 DETECTOR 3 A �C G o 2„ C' 4 f 0 7 DETECTOR 2 2 2 2 <A SCALED 1' = 20' �, I �8 0 8 DETECTOR 2 2 e#8 �4 J TOTAL DLC 18 9 4 4 1 9 5 5 MAS-5A � 3 0 , — 6 , _ _ _ S OPTICOM CABLE 4 2 2 2 1 1 - - INTERCONNECT CABLE 2 1 - - - 1 1 1 » » A R,Y,G =0 2,0 4,0 6 or 0 8 /, 8 3 SEE DAIS � CONDUIT SIZE " " DETAIL A YA,GA=0 1,03 ,05 or 07 4 �3 & �2 o o -3.5 3 2.5 2.5 2.5 2.5 2.5 2.5 4 • COIL & TAPE RED CONDUCTOR FOR FUTURE. PROTECTED PERMITTED SIGNAL DISPLAYS 3 d?6 _.� & X .� 06 DETECTOR SENSOR TABLE �1 _ w SENSOR LOOPS PER O 4 �6 f _� 4 A N NO. CHANNEL DETECTOR SENSOR �--�� o5 1 1 1 — E - 1 • 1 •_•• �1 06 a2 2 1 —W- 5 • 1 .•� �• 2_W— 4 ' o5 � 5 3 2 1 2 — E — 1 3 N_N/ �2 IN N 2 2— E - 6 4 ' �, _ �2 O _-•�'- 1 1 — E - 6 • 3 r 3 _ � �` �2p -------------f 2 1 —W- 2 • 2 4 4 1 2 —w- 5 3 f N ID " A" �4 8C o7 8 2 2 —W- 2 4 65 �r S 1 8C 6 3 MA &�� 8 1 3— E - 6 2 5 8 O 2 SPARE — I — �4 CONSTRUCTION NOTES 6 1 1 — S- 3 0 1 2 1 -N- 7 • 12 4 ❑1 — Furnish and install 8 phase NEMA Type "90" controller assembly with detector 1 2 - S - 3 3 N ` -� AI sensors and auxiliary equipment in a Type P" cabinet (see Special Provisions). •_ p� ; Exact location to be determined by the Engineer. See Sheet #1 - Case #3. 7 2 2 - S- 8 4 cvA 3 'dw •_ --_r-fir2 x 3 ❑2 — Furnish and install TYPE III-BF Service Eqquipment Enclosure with one 50A-IP R1 1 1 `r - circuit breaker for metered si nals, two 3OA-IP circuit breakers for unmetered C, 1 1 —s- 8 . 2CVAU _RAN ___ O 9 lighting and one 15A-IP circuit breaker for metered I.I.S.N.S. See Special 8 / MID . 4 2 1 —N-4 • 2 5 1 Provisions and City Standard Plan 407. 9 1 2 -N- 7 3 •__-�-' 1 1 ❑3 — Furnish and install OPTICOM Model 511 Optical Detector on signal most arm per 2 2 —N- 4 4 - detail this sheet. Phases shall be as shown on the plan. Verify locations prior 1 3— N- 4 2 v _ to installing with manufacturer's representative. 2 3 — S- 8 4 10 ,- � , ® — Furnish and install R73-7 sign (36"X45") per CALTRANS Standard ES-6T, Detail U. r -•� 1 5 — Furnish and install 3" conduit & 3#4 service conductors to SCE ower source. �- A OPTICOM 1 & 6 _� � ❑ _ - CK 1 1 B OPTICOM 2 & 5 340CRpS WAI"K INSTALL POLE PLATE '`' OF - - © — Existing street light pole to be removed by SCE. A OPTICOM 3 & 8 ATTACH TOP OF SV 1 T ` 1 v ❑7 — Install NEMA enclosure on side of controller cabinet for interconnect 12 B OPTICOM 4 & 7 TO POLE PLATE 1 ; sN termination per detail on Sheet 1 of 2 1 . Detector loop locations shall be approved ' N� x 71 by the Engineer in the field prior to installation. 1 p J 2. All detector units shall be dual channel, v rack-mounted, inductive loop type confor- 1 m 0 ming to Detector Systems Model 222C or 1 cn approved equal. R / 11, 1 0 1 3. Detectors shown with a • shall be con- O ` 1' nected to door panel test switches. 12' 1 � v- 4. * Model 562 Discriminator. 1 0' o Y NO. DESCRIPTION OF REVISION DATE CRY FIVE SECTION 1 2� ACCEPTED POLE AND EQUIPMENT SCHEDULE SIGNAL HEAD G ; CITY OF RANCHO CUCAMONGA PLACEMENT PED PUSH � SIGNAL STANDARD SIGNAL MOUNTING Hp Y POLE S , DIMENSIONS I N BUTTONS DI E S 0 S I.I.S.N.S. �A 1-5-8 N0. SIGNAL LUMINAIRE » » , POLE MAST ARM POLE LUMINAIRE TRAFFIC SIGNAL PLAN DESCRIPTION MAST ARM MAST ARM C' B' VEHICLE VEHICLE PEDESTRIAN 0 ARROW G , .� 1 1 26-4-80 45 15 3 - 3 SV-1 -UM MAS/MAS SP_ _1 CS 2 200W Church ST N—A- MILLIKEN AVENUE 11200 2 15 - 12' 3' 3' - SV-2-TA - SP-1 -CS 8 20OW - N and TO NE CORNER OF FOOTHILL �_ AVE ` & MILLIKEN WITH #5 PB AT MAX. 200' CHURCH STREET 326-5-80 45 15 3 3 SV_1 UM MAS SP 1 CS 4 20OW Milliken 4 � ON CENTER. EXTEND I CTO CONTROLLER 5 00 / _� _ ON THE NE CORNER THROUGH NEW CONDUIT _ - 4 15 15 3 3 SV-2-TA SP 1 CS 6 200W E APPROVED BY: - DATE. QRpF ESS/0, L ST CITY ENGINEER R.C.E. S 26 4-80 45 15 3 3 SV-1 -UM MAS MAS SP-1 -CS 6 �— 200W Church TERMINAL COMPARTMENT 4. S. � "1� l��r��1�1� / E 11300 � 6 15 - 12' 3' 3' - SV-2-TA - SP-1 -CS 4 —� 200W - ��a sF� �% NOTE: SPECIAL PROVISIONS FOR DESIGN L�,WRENCE EISEN HART RECOMMENDED v � L.S.E. (J� awn W Q r^ CONSULTTNG ENGINEER 7 24-4-80 35' 15' 3' — 3' SV-1 -UM MAS SP-1 -CS 8 —••-- 200W Milliken AVE FIVE SECTION SIGNAL HEAD No. 13493 -+ 5300 THIS WORK ARE ON FILE DRAWN 2� �. T�. �.. ��. 2� SHEE, Redlands, IN o 7 8 15 - 15' 3' 3' - SV-2-TA - SP-1 -CS 2 1 -6— 200W - � � Ex 3-31-97 L.S.E. Tel: (909) 79a-9242 Fox: (909) �3-4e� SV— 1 —T T MOUNTING DETAIL , P' ,'` IN THE CITY ENGINEER'S -9 2 � 9234 �OF� q CI V1�- T CHECKED DRAWING N0. OFL� CA OFFICE. LiAWRENCE EISEN R.C.E. 13493 /� —�