HomeMy WebLinkAbout2024-02-28 - SupplementalsCode Update
Planning Commission
February 28, 2024
Background
•Comprehensive code update in 2022 with
additional updates in 2023
•Occasional inconsistencies need to be
addressed
•Updates to state law also trigger changes
Code Changes – Density Bonus
Code Changes – ADU’s
•Delete requirement for a deed restriction on the
property
•Restrictions already required by code
•Deed restriction is not needed for enforcement
•State removed the owner/occupancy requirement for
ADU development
•Facilitates faster development of ADU to meet a goal of
our Housing Element
Code Changes – Certificate of Appropriateness
•COA’s approved by Planning Director
•Public hearing no longer offered
•No change in type or intensity of alterations under
Director review
•Designed to facilitate small scale repairs to keep historic
properties in good condition.
Code Changes – Use Descriptions
Noticing & Environmental
•Noticed in the Inland Valley Daily Bulletin on February
13, 2024
•No property notice required – citywide ordinance
•No inquiries on the proposed changes
•Exempt from CEQA under Section 15061(b)(3)
Planning Commission
February 28, 2024
DRC2023-00053 & DRC2024-00044
Project: – A request for site plan and architectural review of a three-story 4,216
square foot mixed-use building on a 3,145 square parcel of land;
Entitlement: Design Review DRC2023-00053 and Variance DRC2024-00044
Zoning Designation: Corridor 1 (CO1)
General Plan Designation: Mixed-Use City Corridor Moderate
Project Overview
Location
Street View
Surrounding Land Uses
The existing Land Use, General Plan, and Zoning Designations for the project
site and adjacent properties are as follows:
Land Use General Plan Zoning
Site Undeveloped MU City Corridor Moderate Corridor 1 (CO1)
North Commercial building MU City Corridor Moderate Corridor 1 (CO1)
South Single-Family Residence MU City Corridor Moderate Corridor 1 (CO1)
East Commercial Center MU City Corridor Moderate Corridor 1 (CO1)
West Parking Lot MU City Corridor Moderate Flood Control/Utility
Corridor (FC/UC)
Overall Site Plan
Unit Composition
UNIT SUMMARY
Residential
Unit Type Unit Size (SF - Net)Number of
Units
1 Bedroom 680 1
2 Bedroom 828 1
Total Number of
Units 2
Commercial Total Area
Commercial (SF)1,314 1,314
Development Code Compliance
Development
Standard Required Proposed Complies
Density 24 to 42 DU/AC 28 DU/AC Yes
Floor Area Ratio
(Non-Residential)0.4 – 1.0 FAR .41 FAR Yes
Setback –
Archibald 0 to 15’0 – 1 Feet Yes
Setback – Estacia 0 to 15’0 – 3 Feet Yes
Setback – Interior None 0 Yes
Rear Yard 5’ min.0 Feet Yes*
Building Height 4 Stories.
40 Feet Max
3 Stories
44 Feet Yes*
*With Approval of Variance DRC2024-00044
Parking
PARKING ANALYSIS
Number of Units Square
Footage
Parking Ratio Required
Parking
Multi-family
unit
(one bedroom)
1 N/A 1.5 per unit
(1 in garage or carport)1.5
Multi-family
unit
(two bedrooms)
1 N/A 2 per unit
(1 in garage or carport) 2
Non-
Residential N/A 925*1 per 250 SF for
commercial units 4
Visitor parking 360 N/A 1 per 3 units 1
Total Garage Parking Required (Covered)2
Total Garage Parking Provided (Covered)7
Total Parking Spaces Required 9
Total Parking Spaces Provided 7**
*With Permitted Deductions
**Variance (DRC2024-00044) Submitted for Parking Reduction
Environmental Assessment
•The project qualifies as Class 3 and Class 5 exemptions under State
CEQA Guidelines.
•Section 15303 covers the construction and location of up to 4 residential
units and up to 10,000 square feet of office/commercial development in
an urbanized area.
•Section 15305 covers minor alterations in land use limitations.
Staff Recommendation
•Staff recommends that the Planning Commission adopt Resolutions 24-05 and
24-06 approving the Minor Design Review DRC2023-00053 and Variance
DRC2024-00044, subject to the attached Conditions of Approval.
Planning Commission
February 28, 2024
DRC2023-00212
DRC2023-00213
Project Overview
•Project: – A request to continue to operate an existing warehouse,
wholesale and distribution, manufacturing and assembly facility within two
existing industrial/warehouse buildings.
•Entitlement: Conditional Use Permits DRC2023-00212, DRC2023-00213
•Address: 8595 Milliken Avenue and 11340 Jersey Boulevard
•Applicant: Kimley Horn
Context & Site
Street View
Proposed Project
•Conditional Use Permit to continue to operate existing warehouse,
wholesale and distribution, manufacturing and assembly facilities within
two existing industrial/warehouse buildings totaling 302,861 square-feet
within the Neo-Industrial (NI) Zone
Floor Plan
Floor Plan
Goals and Policies
•General Plan Policy LC-3.10
•Complimentary to the General Plan Vision
•A new business that is complementary to the surrounding land uses and will provide additional
employment opportunities for City residents and the region.
•Interdepartmental Review
The Fire, Engineering and Building Departments have reviewed the project and have
provided applicable conditions of approval.
Environmental Assessment
•Project is consistent with all applicable General Plan policies.
•The project qualifies as a Class 1 exemption under State CEQA
Guidelines Section 15301 - Existing Facilities Projects which includes
leasing of existing private structures and facilities
Public Noticing
•Advertised in the Inland Valley Daily Bulletin on February 16, 2024
•Notices sent out to all property owners within 1,500 feet on February 13,
2024. To date, staff has not received any responses.
Recommendation
•Staff recommends that the Planning Commission adopt Resolution 24-07
approving Conditional Use Permit DRC2023-00212, and Resolution 24-
08 approving Conditional Use Permit DRC2023-00213 subject to the
attached Conditions of Approval.
Planning Commission
February 28, 2024
DRC2023-00382
Project Overview
•Project: – A request to operate a warehouse, wholesale and distribution
facility within an existing industrial/warehouse building.
•Entitlement: Conditional Use Permits DRC2023-00382
•Address: 10955 Arrow Avenue
•Applicant: Charles Joseph Associates
Context
Street View
Proposed Project
•Conditional Use Permit to operate a warehouse, wholesale and
distribution facility within an existing industrial/warehouse building totaling
124,328 square-feet within the Neo-Industrial (NI) Zone.
Floor Plan
Goals and Policies
•General Plan Policy LC-3.10
•Complimentary to the General Plan Vision
•A new business that is complementary to the surrounding land uses and will provide additional
employment opportunities for City residents and the region.
Interdepartmental Review
•The Fire, Engineering and Building Departments have reviewed the project and have provided
applicable conditions of approval.
Environmental Assessment
•Project is consistent with all applicable General Plan policies.
•The project qualifies as a Class 1 exemption under State CEQA
Guidelines Section 15301 - Existing Facilities Projects which includes
leasing of existing private structures and facilities
Public Noticing
•Advertised in the Inland Valley Daily Bulletin on February 16, 2024
•Notices sent out to all property owners within 1,500 feet on February 13, 2024. To date, staff has not received any responses.
Recommendation
•Staff recommends that the Planning Commission adopt Resolution 24-03
approving Conditional Use Permit DRC2023-00382 subject to the
attached Conditions of Approval.
Planning Commission
February 28, 2024
DRC2024-00017
Who: Manny Badiola (Applicant)
What: A request for a one (1) year time extension of
the approval of SUBTT188305
Where: West side of Hermosa Avenue at Vista Grove
Entitlement: Time Extension DRC2024-00017
Project Description
Background and Project Overview
•On January 13, 2021, the Planning Commission approved Tentative
Tract Map SUBTT18305 for the subdivision of a 4-acre parcel of land
into 6 residential lots;
•That approval included Minor Exception DRC2020-00217 for wall
height and Tree Removal Permit DRC2020-00218 for the removal of
onsite trees.;
•The approval of tentative maps was for three (3) years, or January 13,
2024;
6TH STREET HERMOSA AVEN
Location
Analysis
•The applicant is requesting to extend the approval of SUBTT18305 for
one (1) year to complete the Engineering Department final map
process;
•It is anticipated that the final map process will be completed in the next
several months;
•No changes to the approved tentative map are proposed or are any
changes proposed other than those which affect the expiration date;
•Municipal Code Section 16.16.107 (Extensions) permits up to 5 one-
year times extensions of tentative maps, of which this is the first.
Public Correspondence
This item was advertised as a public hearing with a regular legal
advertisement in the Inland Valley Daily Bulletin newspaper on February
16, 2024, the property was posted on February 15, 2024, and notices
were mailed to all property owners within a 660-foot radius of the project
site on February 13, 2024. No comments have been received in
response to these notifications.
Environmental Review
•Pursuant to the California Environmental Quality Act (“CEQA”), the City
certified a Mitigated Negative Declaration on January 13, 2021, in
connection with the City’s approval of SUBTT18305;
•CEQA Guidelines Section 15162, no subsequent or supplemental EIR
or Negative Declaration is required in connection with subsequent
discretionary approvals of the same project;
Recommendation
Staff recommends the Planning Commission take the following action:
Approve Time Extension DRC2024-00017 through the adoption of the
attached Resolution of Approval with Conditions.