Loading...
HomeMy WebLinkAbout2025-04-23 - Agenda Packet Historic Preservation Commission and Planning Commission Meeting Agenda Rancho Cucamonga Civic Center COUNCIL CHAMBERS April 23, 2025 10500 Civic Center Drive Rancho Cucamonga, CA 91730 7:00 PM A. CALL TO ORDER AND PLEDGE OF ALLEGIANCE ROLL CALL: Chairman Morales Vice Chairman Boling Commissioner Dopp Commissioner Daniels Commissioner Diaz B. PUBLIC COMMUNICATIONS This is the time and place for the general public to address the Planning/Historic Commission (“Planning Commission”) on any Consent Calendar item or any item not listed on the agenda that is within the Commission’s subject matter jurisdiction. The Planning Commission may not discuss any issue not included on the agenda, but may set the matter for discussion during a subsequent meeting. C. CONSENT CALENDAR C1. Consideration to adopt Regular Meeting Minutes of April 9th, 2025. D. PUBLIC HEARINGS D1. DESIGN REVIEW AND CONDITIONAL USE PERMIT – GOREE ARCHITECHTS FOR CAL BOX - A request for site plan and architectural review of a 45,993 square foot addition to an existing 98,406 square foot industrial building and a Conditional Use Permit to operate a manufacturing use within Mixed Employment 2 (ME2) Zone, at 8949 Toronto Avenue; APN: 0209-401-05. The project qualifies as a Class 32 exemption under State CEQA Guidelines Section 15332 – Infill Development Projects. The project also qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 – Existing Facilities (Design Review DRC2023-00379 and Conditional Use Permit DRC2024-00288). E. GENERAL BUSINESS E1. Urban Design Presentation by Torti Gallas. (Verbal Report Only) F. DIRECTOR ANNOUNCEMENTS G. COMMISSION ANNOUNCEMENTS H. ADJOURNMENT TO ADDRESS THE PLANNING COMMISSION The Planning Commission encourages free expression of all points of view. To allow all persons to speak, given the length of the agenda, please keep your remarks brief. If others have already expressed your position, you may simply indicate that you agree with a previous speaker. If appropriate, a spokesperson may present the views of your entire group. To encourage all views and promote courtesy to others, the audience should refrain from clapping, booing or shouts of approval or disagreement from the audience. If you need special assistance or accommodations to participate in this meeting, please contact the City Clerk's office at (909) 477-2700. Notification of 48 hours prior to the meeting will enable the City to make reasonable arrangements to ensure accessibility. Listening devices are available for the hearing impaired. The public may address the Planning Commission on any agenda item. To address the Planning Commission, please come forward to the podium. State your name for the record and speak into the microphone. After speaking, please complete a speaker card located next to the speaker’s podium. It is important to list your name, address (optional) and the agenda item letter your comments refer to. Comments are generally limited to 3 minutes per individual. If you wish to speak concerning an item not on the agenda, you may do so under “Public Communications.” As an alternative to participating in the meeting you may submit comments in writing to Elizabeth.Thornhill@cityofrc.us by 12:00 PM on the date of the meeting. Written comments will be distributed to the Commissioners and included in the record. AVAILABILITY OF STAFF REPORTS Copies of the staff reports or other documentation to each agenda item are available at www.CityofRC.us. APPEALS Any interested party who disagrees with the City Planning Commission decision may appeal the Commission’s decision to the City Council within 10 calendar days. Any appeals filed must be in writing with the City Clerk’s Office, state the reason for the appeal, and be accompanied by an appeal fee pursuant to the most adopted fee schedule for all decisions for the Commission. (Fees are established and governed by the City Council). Please turn off all cell phones while the meeting is in session. I, Elizabeth Thornhill, Executive Assistant of the City of Rancho Cucamonga, or my designee, hereby certify that a true, accurate copy of the foregoing agenda was posted Seventy-Two (72) hours prior to the meeting per Government Code 54954.2 at 10500 Civic Center Drive, Rancho Cucamonga, California and on the City's website. HPC/PC Draft Minutes – April 9, 2025 Page 1 of 3 2 8 3 1 Historic Preservation Commission and Planning Commission Agenda April 9, 2025 Draft Minutes Rancho Cucamonga, CA 91730 7:00 p.m. The regular joint meeting of the Historic Preservation Commission and Planning Commission was held on April 9th, 2025. The meeting was called to order by Vice Chairman Boling at 7:00 p.m. A. Roll Call Planning Commission present: Vice Chairman Boling, Commissioner Dopp, Commissioner Diaz; Chairman Morales and Commissioner Daniels absent. Staff Present: Serita Young, Assistant City Attorney; Sean McPherson, Principal Planner; Jared Knight, Assistant Planner; Claudia Vargas, Associate Planner; Elizabeth Thornhill, Executive Assistant. B. Public Communications There were no public communications. C. Consent Calendar C1. Consideration to adopt Regular Meeting Minutes of March 12, 2025. Motion: Moved by Commissioner Dopp; seconded by Commissioner Diaz. Motion carried 3-0-2, with Chairman Morales and Commissioner Daniels absent. D. Public Hearings D1. CONDITIONAL USE PERMIT – FLORA BUNDA – A request to operate a home décor wholesale, distribution and warehouse facility within an existing 105,858 square foot industrial building within the Neo-Industrial (NI) Zone, located at 8545 Pecan Ave; APN:0229-171-02. This item is exempt from requirements of the California Environmental Quality Act (CEQA) under CEQA Section 15301- Existing Facility (Conditional Use Permit DRC2024-00289). Associate Planner Vargas presented a PowerPoint presentation (copy on file). Commissioner Dopp asked staff whether the applicant conducted onsite sales at their previous location and if they plan to do the same at their new location, or is it merely warehouse oriented.    Page 3 HPC/PC Draft Minutes – April 9, 2025 Page 2 of 3 2 8 3 1 Associate Planner Vargas replied that it is warehouse oriented. The showroom is meant to be for their advertisement only, and it will not be open to the public. Vice Chairman Boling opened the public hearing. Architect Chen attended on behalf of the applicant, who was unable to attend. Vice Chairman Boling inquired whether the expansion into the larger facility resulted in the creation of new jobs. Design Chen confirmed. Hearing no comments from the public, Vice Chairman Boling closed the public hearing. Commissioner Dopp stated that when the Neo Industrial zone was first established, the goal was to attract businesses with a dynamic that goes beyond just warehouses. He expressed disappointment that this element was not present. However, beyond that, the commissioners are always pleased to see businesses grow. Vice Chairman Boling concurred with Commissioner Dopp, stating the goal is to create economic value within the community. He emphasized that the potential for sales tax generation, in addition to business-to-business sales, could increase property tax revenue. Having additional sales tax revenue would be beneficial in an area zoned as Neo Industrial. However, he also expressed his appreciation for the city’s business retention program, which encourages existing businesses to thrive and promotes employment opportunities within the city. Motion: Moved by Commissioner Dopp; seconded by Commissioner Diaz to adopt Resolution 2025-009, Conditional Use Permit DRC2024-00289. Motion carried 3-0-2, with Chairman Morales and Commissioner Daniels absent. D2. ZONING MAP AMENDMENT – CITY OF RANCHO CUCAMONGA – A request to change the zoning map designation of two parcels located at 9750 and 9720 7th Street from, Center 1 – Southwest Cucamonga (CE1-SC) to Neo-Industrial (NI), to correct an inconsistency with the General Plan Land Use Map. This project qualifies for a statutory exemption under State CEQA Guidelines section 15061(b) (3), as the proposed zoning map amendment will not have any direct impact on the environment. APNs: 0209-211-68, 0209-211-69. Assistant Planner Knight presented a PowerPoint presentation (copy on file). Vice Chairman Boling opened the public hearing. Hearing no comments from the public, Vice Chairman Boling closed the public hearing. Motion: Moved by Commissioner Dopp; seconded by Commissioner Diaz to adopt Resolution 2025-010, Zoning Map Amendment DRC2025-00044. Motion carried 3-0-2, with Chairman Morales and Commissioner Daniels absent. E. Director Announcements Principal Planner McPherson stated that the next meeting is scheduled for April 23rd and that a special presentation on Urban Design will be included.    Page 4 HPC/PC Draft Minutes – April 9, 2025 Page 3 of 3 2 8 3 1 F. Commission Announcements Commissioner Dopp formally welcomed back Serita Young. We are all excited to have her back with us again. G. Adjournment Motion: Moved by Commissioner Diaz, seconded by Commissioner Dopp to adjoin the meeting. Hearing no objections, Vice Chairman Boling adjourned the meeting at 7:20 p.m. Respectfully submitted, Elizabeth Thornhill, Executive Assistant Planning Department Approved:    Page 5 DATE:April 23, 2025 TO:Chairman and Members of the Planning Commission FROM:Jennifer Nakamura, CNU-A, Planning Director INITIATED BY:Tabe van der Zwaag, Associate Planner SUBJECT:DESIGN REVIEW AND CONDITIONAL USE PERMIT – GOREE ARCHITECHTS FOR CAL BOX - A request for site plan and architectural review of a 45,993 square foot addition to an existing 98,406 square foot industrial building and a Conditional Use Permit to operate a manufacturing use within Mixed Employment 2 (ME2) Zone, at 8949 Toronto Avenue; APN: 0209-401-05. The project qualifies as a Class 32 exemption under State CEQA Guidelines Section 15332 – Infill Development Projects. The project also qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 – Existing Facilities (Design Review DRC2023-00379 and Conditional Use Permit DRC2024-00288). RECOMMENDATION: Staff recommends that the Planning Commission adopt the resolutions of approval for Design Review DRC2023-00379 and Conditional Use Permit DRC2024-00288, subject to the attached Conditions of Approval. BACKGROUND: The project site is located at 8949 Toronto Avenue and is developed with a 98,406-square-foot industrial building constructed in 1995 by Cal Box. Cal Box manufactures and distributes custom designed corrugated boxes for businesses. They are proposing an expansion of their existing facility to store raw materials and finished goods manufactured on site. The parcel is approximately 532 feet from east to west and 613 feet from north to south, with an area of approximately 336,283 square feet (7.7 acres). The right-of-way improvements, including sidewalk, curb, gutter, landscaping, and utility undergrounding along Toronto Avenue, have been completed and will remain as part of this project. The existing Land Use, General Plan, and Zoning designations for the project site and adjacent properties are as follows: Land Use General Plan Zoning Site Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) North BNSF/Metrolink Right of Way -- South Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) East Vacant Land City Center Center 2 (CE2) West Industrial Building 21st Century Employment District Mixed Employment 2 (ME2)    Page 6 Page 2 of 5 2 7 9 2 ANALYSIS: The applicant proposes constructing a 45,993-square-foot addition along the west elevation of the existing 98,406-square-foot industrial building. The addition will be used to store raw materials and finished goods related to the site's primary manufacturing use, which is proposed to continue in relation to the subject request for entitlements. While the use is permitted with a Conditional Use Permit (CUP) pursuant to Development Code Section 17.136.020 (Allowed Land Uses), the existing building is nonconforming in terms of street-side setbacks. Development Code Section 17.62.030-B (Alterations and Additions to Nonconforming Uses and Structures) states: “No nonconforming structure shall be altered or reconstructed in a way that increases the discrepancy between existing conditions and the standards for front yard, side yards, rear yard, height of structures, distances between structures, and parking facilities.” The proposed addition will reduce the discrepancy between current conditions (190-foot setback from the face of the curb on Toronto Avenue) and the required setbacks (15 feet minimum), as the addition will bring the overall building closer to the street (70 feet from the face of the curb). Figure 1: Site Plan    Page 7 Page 3 of 5 2 7 9 2 Design The proposed building addition will be of concrete tilt-up construction and designed to match the existing building, including the use of form lines and high windows. A two-story design element with glazing has been added to the southwest corner of the addition to create an office-like appearance, along with new landscaping along the west and south elevations and decorative paving at the main vehicle entrance. The landscaping in the existing parking lot area will be enhanced to meet current landscape requirements, including the addition of trees, shrubs, and ground cover. The existing and new loading areas, dock doors, and trailer parking stalls will be located on the north and south elevations of the building and screened from public view by an existing wall and by the building. Figure 2: Colored Rendering Development Code Conformity The project was designed to bring the site into closer conformance with development standards of the Mixed Employment 2 (Zone) including building and parking setbacks, number of parking spaces, and floor area ratio as shown in the following tables: Required Provided Compliant? Building Setback (Street)15 Feet Maximum 70 Feet Yes* Building Setback (Side)N/A 40 and 50 Feet Yes Building Setback (Rear)N/A 135 Feet Yes Parking Setback 10 Foot Minimum 81 Feet Yes Landscape Coverage N/A 10.8 Percent Yes Floor Area Ratio .4 – 2.0 Percent 43 Percent Yes Building Height 4 Stories (Maximum)1 Story Yes *The proposed addition will bring the building into greater conformance with the required streetside setback in compliance with Development Code Section 17.62.030-B related to Nonconforming Uses and Structures.    Page 8 Page 4 of 5 2 7 9 2 Parking Ratio Required Parking Provided Parking Office Parking (5,585 SF)1:250 SF 22 Spaces 22 Spaces Manufacturing (11,779 SF)2:1,000 SF 24 Space 24 Space Warehouse Parking (180,186 SF) 1:1,000 for 1st 20,000 SF 1:2,000 for 2nd 20,000 SF 1:4,000 for the Remaining SF 48 Spaces 48 Spaces Total Vehicle Parking 94 Spaces 94 spaces Trailer Parking 1 per Dock High Door 11 Spaces 11 Spaces Conditional Use Permit Per Development Code Table 17.136.020-1 (Allowed Land Uses in Form-Based Zones), manufacturing facilities exceeding 50,000 square feet are classified as Light Manufacturing Large and require a Conditional Use Permit (CUP). With the proposed expansion, the existing manufacturing use is required to obtain a CUP to comply with this requirement. Cal Box operates 24 hours a day, Monday through Friday, with up to 64 employees working in two shifts. During peak periods, up to two Saturday shifts may be added per month between 2:00 a.m. and 5:30 p.m. Office personnel work from 8:00 a.m. to 5:00 p.m., Monday through Friday. On average, 20 trucks access the site daily. The expansion will not increase the number of employees or vehicles accessing the site but will relocate existing outdoor activities indoors. The site has sufficient parking to accommodate the current staff, trucks, and trailers. Design Review Committee The Design Review Committee (DRC – Daniels and Boling) reviewed the project on October 1, 2024. Staff presented the item, and committee members inquired about nonconforming setbacks and compliance with other development standards. Committee members also asked the applicant about their business history in Rancho Cucamonga and operations related to the proposed addition. They noted that colored renderings were missing from the plan set and requested that the applicant provide a rendering before the item goes to the Planning Commission. The full set of plans attached as Exhibit B includes the requested color renderings. Public Art This project is required to comply with the public art ordinance as outlined in Chapter 17.124 of the Development Code. Based on the area of the proposed addition, the total art value required    Page 9 Page 5 of 5 2 7 9 2 per Section 17.124.020.C. is $45,993 ($1 per square foot). A condition has been included pursuant to the Development Code that requires the public art requirement to be fulfilled prior to occupancy. Environmental Assessment Planning staff determined that the project is categorically exempt from the California Environmental Quality Act (CEQA) under: •Section 15332 (Infill Development Projects): Covers infill developments on sites less than 5 acres, with no significant impact on traffic, noise, air quality, or water. •Section 15301 (Existing Facilities): Covers the Conditional Use Permit requirement for a Manufacturing Use (Large) over 50,000 square feet in the ME2 Zone. A Section 15332 CEQA exemption was prepared by UES (April 2025), an environmental consultant hired by the City (Exhibit D – CEQA Section 15332 Infill Exemption). Staff reviewed the exemption and confirmed that the project meets CEQA criteria and does not significantly impact biological resources, traffic, noise, air quality, or water. While the overall site is approximately 7.7 acres in area, the area disturbed by the proposed improvements is significantly below the 5-acre limit permitted by the Section 15332 exemption. The proposed addition will replace a paved area currently used for outdoor storage with an enclosed building. The Planning Director independently reviewed and concurred with staff’s findings. Correspondence This item was advertised as a public hearing with a regular legal advertisement in the Inland Valley Daily Bulletin newspaper on April 8, 2025, the property was posted on April 9, 2025, and notices were mailed to 15 property owners within a 660-foot radius of the project site on April 8, 2025. To date, Staff has not received any comments related to the project to date. FISCAL IMPACT: The project site is currently assessed an annual property tax. A percentage of this annual tax is shared with the City. The proposed building addition will increase the value of the project site, and the City’s annual share of the property tax will increase accordingly. COUNCIL MISSION / VISION / VALUE(S) ADDRESSED: The project supports the City Council's core value of the relentless pursuit of improvement by increasing the operational efficiency of an existing manufacturing use within the city. The addition will allow for the relocation of outdoor storage into an enclosed building, reducing visual clutter and enhancing site aesthetics. EXHIBITS: Exhibit A – Project Location Exhibit B – Project Plans Exhibit C – DRC Comments and Meeting Minutes dated October 1, 2024 Exhibit D – Section 15332 Categorical Exemption Memorandum Exhibit E – Draft Resolutions of Approval with Conditions of Approval    Page 10 •.... p ... ,, T "" §)�•�o. ... � . !,,... · . p � .. Project Location Exhibit A    Page 11 &$/￿%2;￿,,￿:$5(+286(￿(;3$16,21 ￿￿￿￿￿7252172￿$9(18(￿￿5$1&+2￿&8&$021*$￿￿&$￿￿￿￿￿￿ $5&+,7(&76￿352-(&7￿￿ &￿￿￿￿￿ '(6,*1￿5(9,(: ￿￿￿￿￿￿￿￿ ￿￿ 7+,6￿'5$: ,1*￿$1'￿7+(￿%,0￿&$'￿),/(￿)520￿: +,&+￿,7￿+$6￿%((1￿*(1(5$7('￿$5(￿3529,'('￿$6￿$1￿,167580(17￿2)￿6(59,&(￿)25￿7+,6￿352-(&7￿ 7+(6(￿'2&80(176￿$5(￿7+(￿62/(￿3523(57<￿*25((￿$5&+,7(&76￿￿,1&￿￿$1<￿86(￿2)￿7+(6(￿'2&80(176￿￿'$7$￿$1'￿'(6,*16￿)25￿385326(6￿27+(5￿7+$1￿7+26(￿$662&,$7('￿: ,7+￿7+,6￿352-(&7￿: ,7+287￿7+(￿(;35(66('￿￿: 5,77(1￿3(50,66,21￿2)￿*25((￿$5&+,7(&76￿￿,1&￿￿,6￿352+,%,7('￿ &2168/7$176 0(3 &,9,/6758&785$/ *.￿(1*,1((56 ￿￿￿￿￿:￿/223￿6￿￿68,7(￿￿￿￿ %(//$,5￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ &'5 '$//<￿$662&,$7(6 ￿￿￿￿￿5,&+021'￿$9(18(￿￿68,7(￿￿￿￿ +286721￿￿7;￿￿￿￿￿￿ ￿￿￿￿72:1￿&(17(5￿'5,9(￿￿68,7(￿￿￿￿ &267$￿0(6$￿￿&$￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿*.￿0(3￿&20 :::￿&'5:(67￿&20 '$//<$662&,$7(6￿&20 $￿352-(&7￿)25 &$/￿%2;([KLELWꢀ%ꢀꢁꢀ3URMHFWꢀ3ODQV 67$03￿￿￿6,*1$785( )25￿,17(5,0￿5(9,(:￿ 127￿,17(1'('￿)25￿ %,'',1*￿3(50,7￿25 &216758&7,21￿385326(6 58'2/)2￿5￿￿3$*6$1-$1￿ -5￿￿￿￿￿￿￿￿    Page 12 SD MH RAILROAD SPUR PP FH WV PP EDISON MH FH GATEKRAILCONCRETE SWALE GATE FH WV GATE 2 PROPANE FF 1110.86 FF 1111.43 TANKS FF 1111.40 FF 1111.86 FIRE SERVICE LOADING DOCK FF 1111.75 FF 1110.20 FF 1110.12 UTILITY MH CO GUY POLE FH VICINITY MAPLOT LT STRUCTURAL STEEL POST ON CONCRETE WV FH N.T.S. AIR FF 1109.99 EASEMENT NOTESAIRFIRST AMERICAN TITLE COMPANY ORDER NO. NCS-1166801-ONT1 FEBRUARY 6, 2023 UTI UNIT 4" FIRE COMMERCIAL BUILDING 5 EASEMENT TO CUCAMONGA WATER COMPANY RECORDED FEBRUARY 10, 1888 IN BOOK 69 OF DEEDS, PAGE 314. LOCATION CANNOT BE LOCATED FROM RECORD INFORMATION FF 1111.30 CO 6 7 8 9 EASEMENT TO METROPOLITAN WATER DISTRICT OF SOUTHERN CALIFORNIA RECORDED OCTOBER 8, 1936 AS BOOK1168, PAGE 50 OF OFFICIAL RECORDS. RESOLUTION NO. 81-94, VACATION OF CLEVELAND AVENUE RECORDED JUNE 29, 1981 AS DOCUMENT NO. 81-142194 OF OFFICIAL RECORDS. CCR FHWV PARCEL 27 PARCEL MAP NO, 6194 GRANT OF RAILROAD EASEMENTS RECORDED JUNE 21, 1983 AS INSTRUMENT NO. 83-136515 OF OFFICIAL RECORDS. FF 1109.74 10 RESOLUTION NO, 83-99, VACATION OF 8TH STREET RECORDED JULY 5, 1983 AS INSTRUMENT NO. 83-148882 OF OFFICIAL RECORDS. 11 COVENANTS OF AGREEMENT RECORDED JULY 18, 1983 AS INSTRUMENT NO. 83-160413 OF OFFICIAL RECORDS. 12 EASEMENT TO CADILLAC FAIRVIEW/CALIFORNIA, INC. FOR RAILROAD AND INCIDENTAL PURPOSES RECORDED FEBRUARY 4, 1985 AS INSTRUMENT NO. 85-027233 OF OFFICIAL RECORDS. 13 CCR TRANSFORMERS ON CONCRETE PAD GV FIRE SERVICE STRUCTURAL STEEL POST ON CONCRETE PIER ON CONCRETE AIR 14 EASEMENT TO CITY OF RANCHO CUCAMONGA RECORDED JUNE 15, 1995 AS INSTRUMENT NO. 95-206651 OF OFFICIAL RECORDS. 15 EASEMENT TO METROPOLITAN WATER DISTRICT OF SOUTHERN CALIFORNIA RECORDED JULY 7, 1995 AS INSTRUMENT ON.95-231996 OF OFFICIAL RECORDS. AIR FF 1110.32 WV FH FF 1109.24 8" DRNLOT LT 4" PIPE FH FF 1110.558" DRN STRUCTURAL STEEL POST ON CONCRETE PIER ON CONCRETE RF 1145.25 FF 1109.38 FF 1109.12 FF 1109.04 RF 1147.77GATEFF 1109.29 EDISON BX FF 1109.87 RF 1141.86 RF 1146.02 RD RD 4" TRENCH DRN4" FIRE 8" FIRE 2" BFP TRANSFORMER AND EDSION BX ON CONCRETE PADUTL BX SMH4" FIRE 2" BFP SCO WMSMH LOT LT FF 1110.16 WM WMWM STLT SIGN GATE FH WV SIGN SIGN FH SMH LOT LT LOT LT LOT LT LOT LT UTL BX GTE BX WV WV WV WV FH SMH DRAWN BY: CHECKED BY: DATE:TOPOGRAPHIC SURVEY SHEET CG-01 REVISIONS PLANS PREPARED BY:A 05/01/24 NUMBER DATE APP'V'D BENCHMARK:CAL BOXTHE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74.8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 ELEVATION : 1117.66 01 OF 04BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET.,N 89°31'52"E    Page 13 APN: 0209-143-07-0000 NEO INDUSTRIAL APN: 0209-143-26-0000 NEO INDUSTRIALAPN: 0209-143-08-0000 NEO INDUSTRIAL APN: 0209-143-13-0000 NEO INDUSTRIAL APN: 0209-143-05-0000 NEO INDUSTRIAL APN: 0209-143-11-0000 APN: 0209-143-27-0000NEO INDUSTRIAL NEO INDUSTRIAL VICINITY MAP N.T.S. APN: 0209-143-10-0000 RAILROAD INDUSTRIAL APN: 0209-143-14-0000 RAILROAD INDUSTRIAL ATCHISON TOPEKA AND SA OWNER/APPLICANT CALIFORNIA BOX 2PARCEL/USE DATAEIGHT STREET (VACATED)8949 TORONTO AVE.PARCEL MAP NO.APN ZONING USE RANCHO CUCAMONGA, CA 91730 ORANGE EMPIRE ACRES M.B. 20/1 ARCHITECT0209-143-05-0000 NEO INDUSTRIAL NEO INDUSTRIAL APN:GOREE0209-272-30-0000 CITY CENTER CENTER 2 ZONE MAP 20032 P.M. 251/83-84 PAR. 1 0209-143-07-0000 0209-143-08-0000 0209-143-10-0000 0209-143-11-0000 0209-143-13-0000 0209-143-14-0000 0209-143-26-0000 NEO INDUSTRIAL NEO INDUSTRIAL INDUSTRIAL NEO INDUSTRIAL NEO INDUSTRIAL RAILROAD 5151 SAN FELIPE ST. SUITE 1700 HOUSTON, TX 77056 CONTACT: RUDY PAGSANJAN TEL: 713-660-6102MAP 19637 P.M.247/93-94 PAR.3 MAP 19637 P.M.247/93-94 PAR. 4 CIVIL ENGINEER MAP 19637 P.M.247/93-94 PAR. 5 COMMERCIAL DEVELOPMENT RESOURCES 695 TOWN CENTER DR. SUITE #110 COSTA MESA, CA 92626 CONTACT: AARON ALBERTSON, P.E. TEL: 949-351-5325 NEO INDUSTRIAL NEO INDUSTRIAL INDUSTRIAL NEO INDUSTRIAL NEO INDUSTRIAL RAILROAD APN: 0209-401-03-0000 APN: 0209-401-04-0000 APN: 0209-401-05-0000 MAP 19637 P.M.247/93-94 PAR. 221ST CENTURY EMPLOYMENT MIXED EMPLOYMENT 2 ZONE 21ST CENTURY EMPLOYMENT MIXED EMPLOYMENT 2 ZONE 21ST CENTURY EMPLOYMENT MIXED EMPLOYMENT 2 ZONE MAP 19637 P.M.247/93-94 PAR. 6 SURVEY MAP 19637 P.M.247/93-94 PAR. 1 COMMERCIAL DEVELOPMENT RESOURCES 695 TOWN CENTER DR. SUITE #110 COSTA MESA, CA 92626 CONTACT: AARON ALBERTSON, P.E. TEL: 949-351-5325 NEO INDUSTRIAL NEO INDUSTRIAL ORANGE EMPIRE ACRES M.B. 20/1 0209-143-27-0000 NEO INDUSTRIAL NEO INDUSTRIAL ORANGE EMPIRE ACRES M.B. 20/1 0209-272-20-0000 0209-272-26-0000 0209-272-30-0000 0209-401-03-0000 0209-401-04-0000 0209-401-05-0000 0209-401-06-0000 0209-401-22-0000 0209-401-23-0000 0209-411-18-0000 0209-411-19-0000 EMPIRE LAKES SPECIFIC PLAN CITY CENTER PROJECT INFORMATION ORANGE EMPIRE ACRES M.B. 20/1 FLOOD CONTROL/UTILITY CORRIDOR GENERAL OPEN SPACE 1. PER FEMA MAP NO. 06071C8635J, EFFECTIVE DATE: SEPTEMBER 26, 2014 THE PROPERTY IS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN AND LOCATED WITHIN FLOOD ZONE X.MAP 148-36-63A PAR. 1 MAP 148-36-63A PAR. 1 CENTER 2 ZONE CITY CENTER 2. NOT SUBJECT TO LIQUEFACTION OR OTHER GEOLOGICAL HAZARDS, SAID PROPERTY IS NOT IN ANY SPECIAL STUDY ZONES.APN: 0209-272-20-0000 CITY CENTER MIXED EMPLOYMENT 2 MIXED EMPLOYMENT 2 MIXED EMPLOYMENT 2 MIXED EMPLOYMENT 2 MIXED EMPLOYMENT 2 MIXED EMPLOYMENT 2 MIXED EMPLOYMENT 2 MIXED EMPLOYMENT 2 21ST CENTURY EMPLOYMENT 21ST CENTURY EMPLOYMENT 21ST CENTURY EMPLOYMENT 21ST CENTURY EMPLOYMENT 21ST CENTURY EMPLOYMENT 21ST CENTURY EMPLOYMENT 21ST CENTURY EMPLOYMENT 21ST CENTURY EMPLOYMENT MAP 20032 P.M. 251/83-84 PAR. 1 3. SETBACKS OF SLOPES TO PROPERTY LINES SHALL CONFORM TO THE CITY OF RANCHO CUCAMONGA MUNICIPAL CODE REQUIREMENTS. 4. NO EXISTING STRUCTURES LOCATED ON SITE. 5. ALL SLOPES ARE AT A MAXIMUM OF 2:1 RATIO 6. TOTAL PARCEL ACREAGE: 336,283 SF / 7.72 AC MAP 872-36-112 PAR. 2 MRO MAP 19762 P.M. 250/72-74 PAR. 1 MAP 19762 P.M. 250/72-74 PAR. 2 MAP 19762 P.M. 250/72-74 PAR. 3 APN:MAP 148-36-63B PAR. 1 MAP 148-36-63B PAR. 1APN: 0209-401-23-0000 21ST CENTURY EMPLOYMENT MIXED EMPLOYMENT 2 ZONE 0209-401-06-0000 21ST CENTURY EMPLOYMENT MIXED EMPLOYMENT 2 ZONEAPN: 0209-401-22-0000 21ST CENTURY *PER CITY OF RANCHO CUCAMONGA ARCGIS ZONING PLAN VIEWER (ZONING) & GENERAL PLAN VIEWER (LAND USE) EMPLOYMENT MIXED EMPLOYMENT 2 ZONE APN: 0209-411-18-0000 21ST CENTURY EMPLOYMENT MIXED EMPLOYMENT 2 ZONE APN: 0209-411-19-0000 21ST CENTURY EMPLOYMENT MIXED EMPLOYMENT 2 ZONE APN: 0209-272-26-0000 GENERAL OPEN SPACE FLOOD CONTROL/UTILITY CORRIDOR DRAWN BY:AM UTILIZATION MAP SHEET CG-02 REVISIONS PLANS PREPARED BY:CHECKED BY: AMA DATE:05/01/24 NUMBER DATE APP'V'D BENCHMARK:CAL BOXTHE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74.8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 ELEVATION :1117.66 05/01/2024 02 OF 04BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET., AARON M. ALBERTSON R.C.E. 65513, EXP. 9/30/25N 89°31'52"E    Page 14 LEGEND:ABBREVIATIONS: PROP. 26-FT WIDE MULTI-USE TRAIL.FINAL LOCATION TO BE (XX.XX) EXISTING ELEVATIONEXISTING CONCRETE EXISTING LANDSCAPE PROP. CONCRETE PROP. LANDSCAPE PROP. MULTI-USE TRAIL EXISTING CONTOUR EXISTING WALL DETERMINED BY CITY ENGINEER BOW CF ELEV ELEC EX BACK OF WALK CURB FACE ELEVATION ELECTRICAL EXISTING FF FL FINISH FLOOR FLOW LINE FG FS GBINV MAX MH MIN MWD FINISH GRADE FINISH SURFACE GRADE BREAKINVERT MAXIMUM MANHOLE MINIMUM MUNICIPAL WATER DISTRICT 7.41TC (6.91FS)XXXX 8.20DOOR 8.50FSDOOR 9.24FF9.22FS(6.58TC)(6.08FS)PROJECT INFORMATION PROPERTY LINEINTERIOR RAMP TO @10% MAX9.24FF OC TC TGTYP W ON CENTER TOP OF CURB TOP OF GRATETYPICAL 1. PER FEMA MAP NO. 06071C8635J, EFFECTIVE DATE: SEPTEMBER 26, 2014 THE PROPERTY IS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN AND LOCATED WITHIN FLOOD ZONE X. CENTERLINEEXISTING PROPANE TANKS TO BE REMOVED PROP. ADA PATH OF TRAVEL PROP. CONTOUR WIDTH (6.46TC) (6.34TC) 6.53 9.24FF 9.22FS 2. NOT SUBJECT TO LIQUEFACTION OR OTHER GEOLOGICAL HAZARDS, SAID PROPERTY IS NOT IN ANY SPECIAL STUDY ZONES. WM WATER METER FS 9.12TS (10.30FS) (10.20FF) 3. SETBACKS OF SLOPES TO PROPERTY LINES SHALL CONFORM TO THE CITY OF RANCHO CUCAMONGA MUNICIPAL CODE REQUIREMENTS. :PROP. WATER LATERAL PROP. SEWER LATERAL PROP. STORM DRAIN LIMITS OF WORK 6.51 FS (5)-6"RISERS 6.62FS-BS 66 4. ALL SLOPES ARE AT A MAXIMUM OF 2:1 RATIO 5. TOTAL PARCEL ACREAGE: 336,283 SF / 7.72 AC(9.90FS)6'VICINITY MAP(6.36TC) (6.06TC) (10.14FS) 10.12FFADJUST INTERIORSLAB TO 9.24 FF(9.99FF) EXISTING FIRE HYDRANT TO BE REMOVED UTILITY PROVIDERS N.T.S.EXISTING EASEMENT SEE CG-01 FOR FURTHER DETAILSELECTRICITY: SOUTHERN CALIFORNIA EDISON GAS: SOUTHERN CALIFORNIA GAS WATER: CUCAMONGA VALLEY WATER DISTRICT CABLE: SPECTRUM 800-655-4555 800-427-2200 909-944-6000 888-892-4357 9.24FF-GB 2.0%OWNER/APPLICANT CIVIL ENGINEER SOILS ENGINEER PERVIOUS/IMPERVIOUS AREAS:PROP. STORM DRAIN FOR ROOF DRAINAGE CHRIS WALDERA, PRESIDENT CALIFORNIA BOX II 8949 TORONTO AVE. RANCHO CUCAMONGA TEL: 909-944-9202 COMMERCIAL DEVELOPMENT RESOURCES 695 TOWN CENTER DR. SUITE #110 COSTA MESA, CA 92626 CONTACT: AARON ALBERTSON, P.E. TEL: 949-351-5325 NORCAL ENGINEERING 10641 HUMBOLT ST LOS ALAMITOS, CA 90720 CONTACT: SCOTT SPENSIERO TEL: 562-799-9469 PROPOSED DISTURBED AREA: 65,430 SF PROPOSED/REPLACED IMPERVIOUS AREA: 57,128 SF PROPOSED PERVIOUS AREA: 8,302 SF TOTAL SITE AREA: 321,374 SF (7.37 ACRES) 2.0%ARCHITECT SURVEY PRELIMINARY EARTHWORK(5.81TC) (5.69TC) GOREE COMMERCIAL DEVELOPMENT RESOURCES 695 TOWN CENTER DR. SUITE #110 COSTA MESA, CA 92626 CONTACT: AARON ALBERTSON, P.E. TEL: 949-351-5325 RAW CUT: 80 CY RAW FILL: 2543 CY5151 SAN FELIPE ST. SUITE 1700 HOUSTON, TX 77056 CONTACT: RUDY PAGSANJAN, AIA TEL: 832-463-0007PARCEL 27 PARCEL MAP NO, 6194 EXPORT: 2463 CY FILL 9.24 FF-GB (9.74FF)THESE ARE ENGINEERING ESTIMATES ONLY AND THE CONTRACTOR IS REQUIRED TO PERFORM THEIR OWN TAKE-OFFS FOR EARTHWORK. 8.57FG (10.16FF) 10.14FS(5.52TC) (5.27TC) PROP. STORM DRAIN FOR ROOF DRAINDOWNSPOUT 10.04FS-GB2.0% 5.39FS EX. RAMP TO BEREMOVED& REPLACED 9.24FF9.22FS 9.27 FS-GB W/ ADA ACCESS RAMP5.36FS 9.12TS(7)-6-1/4"RISERS5.48 FS-BS (9.24FF)MATCH (9.05TC)(8.68FS)EXISTING 8" DRAININLETS TO BE REMOVED (1.5%)MATCH (8.46TC)(7.96FS) 9.66TC9.16FS-GB 9.16FS-GB (8.50FS)8.57FG 9.66TC 9.16FS-GB PROPOSED SS LATERALMIN INV = 1101.6067TOP OF PIPE = 1102.1067PIPE COVER = 6.20 FEET PROP. ADA (4.34TC)(3.84FS) ACCESS RAMPEX. TRANSFORMER TO BE RELOCATED PROP. 9.24FF 9.22FS 9.24FF 9.22FS DETAIL A: PROPOSED ADA ACCESS/PARKING IMPROVEMENTS LIMITSOF SAWCUT(4.14TC)9.24FF9.22FS 9.24FF 9.22FS(7.65FS)7.58 FS-GB 5' PROP. 6" SEWER LATERAL POCTO EX. SEWER MH (4.19TC)(3.77FS)9.03FS PROPOSEDLPG (4.31TC)STATION EX. SSMH MATCH(8.63TC)(8.13FS) TO REMAIN (8.16FS)EX. SSMHTO REMAIN 1100.25INV (APPROX.)8.24TC 7.74FS (8.12FS) (7.99FS) (4.06TC) 8.22TC7.72FSMATCH(7.46FS)(3.82TC) (4.44TC) 5.20TC-FS EX. WALL TOEX. 8" FIRE SERVICE DCDA BE REMOVED.LIMITS OF SAWCUT/DEMOFOR NEW CONCRETE PAVEMENT (7.59FS)(5.54TC) (5.07FS)NEW EXT. CURB TOBE INSTALLED (8.06FS) (7.98FS) (8.08FS) TO REMAIN (8.38TC)ENDEX. WATERMETERS & BACKFLOWSTO REMAIN 7.58FS-GB (7.35FS)CURB (7.79FS)(7.88FS)(1.1%)(6.85FS)(7.84FS) PROP.UNDERGROUNDINFILTRATION BMP.SEE PWQMP/HYD (1.1%)(6.77FS) 7.24TC (6.74FS) 7.51FS-GB (7.12FS) 1.53TC (1.1%)7.64FS (1.03FS)2.03TC 9' TYP.1.53FL 1.65FS (2.88TC)2.43FS 7.22TC 8.16TC (8.12TC)(7.55FS) 1.36TC(0.88FS) MATCH(7.01FS-GB)(7.68FS)(7.90FS) 18' 6'6'(6.72FS) 4.57TC 7.24TC (7.57FS) (8.04TC)7.54FS 7.80FS (7.83FS)(4.07FS)(4.16FS)(4.40FS) (4.37FS) (5.45FS) (5.37FS) (5.54FS) (5.53FS) (6.07FS) (6.00FS) (6.74FS)(7.00FS) (7.29TC) (6.82FS)MATCH(6.80FS) 7.36FS-GB (7.48FS) 7.48FS(2.92TC) (2.47FS) 2.00TC 1.50FL1.62FS 4.48TC(3.98FS) (4.08FS) (7.26TC)(6.75FS)PROP. ADA ACCESSIBLE PATHWAYTO PUBLIC ROW.RESTRIPE STALLS (6.67FS)MATCH (6.65FS)MATCH(7.94TC)(7.44FS) DETAIL A: ADA PARKING (8.47TC) (7.21FS)IMPROVEMENTS SCALE: 1":10' DRAWN BY:AM CONCEPTUAL GRADING PLAN SHEET CG-03 REVISIONS PLANS PREPARED BY:CHECKED BY: AMA DATE: 05/01/24 APP'V'D BENCHMARK:NUMBER DATE CAL BOXTHE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74.8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 ELEVATION :1117.66 05/01/2024 03 OF 04BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET., AARON M. ALBERTSON R.C.E. 65513, EXP. 9/30/25N 89°31'52"E    Page 15 VICINITY MAP N.T.S. WEST114 PL 114 112 110 108 106 104 102 100 12.6' EXIST. DRIVEAISLE 18.0' EXIST. PARKINGSTALL 28.3' PROPOSEDLANDSCAPE BUEIXLIDSITN.G1109.74FF112 110 108 106 104 102 100 1109.24FF1108.57FS PROPOSEDBUILDINGEXPANSION1109.24FFEXISTINGPROPOSED GRADE EXISTING WALLCONCRETETO BE REMOVEDGUTTER (1104.12FL)(1104.22FS) (1105.63TC) (1105.13FS)EXISTING GRADEEXISTING GRADEEXISTING GRADE SECTION "A-A" SCALE:1"=10' NORTH PL 118 0.6'118 116 19.2' EXISTING LANDSCAPE 23.6' STORAGE AREA 3.0'23.5'EXISTING BUILDING 1110.86FF116 114 112 110 EXIST. GUTTER EXISTING DRIVE AISLE 1111.46EG EXISTINGGRADE EXISTINGEDGE OFPAVEMENT 1110.40FL 114 112 110 1110.84FSEXISTINGGRADE1110.78EG 1110.53FS 1110.52FS 108 106 108 106 SECTION "B-B" SCALE:1"=5' EAST PL118 116 1.9' SIDEWALK 26.1'15.9' EX. LANDSCAPE 118 116 EXISTING BUILDING 1110.31FF EXISTING DRIVE AISLE 1113.87EG 114 112 110 114 112 110 1110.44TC1111.09TC1110.67FS 1109.72FLEXISTINGGRADE 108 106 108 106 SECTION "C-C" SCALE:1"=5' 116 114 51.2'EXISTING STORAGE AREA 65.7'18.0'5.0' ADA PATH OF TRAVEL 8.0'24.6'19.9'5.9' PL 116 114EXISTING BUILDING 1109.15FF EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING DRIVE AISLE PARKING STALL LANDSCAPE DRIVE AISLE PARKING STALL LANDSCAPE 112 110 108 106 104 102 100 98 EXISTINGGRADE EXISTINGGRADE 112 110 108 106 104 102 100 98 1105.50 1105.63TC1105.45FL 1105.27TC 1104.88FS 1102.661105.52 FS EGFS1103.91TC1103.41FL SECTION "D-D" SCALE:1"=10' DRAWN BY:AM SITE SECTIONS SHEET CG-4 REVISIONS PLANS PREPARED BY:CHECKED BY: AMA DATE: 05/01/24 APP'V'D BENCHMARK:NUMBER DATE CAL BOX 8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 THE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74. ELEVATION :1117.66 05/01/2024 4 OF 04BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET., AARON M. ALBERTSON R.C.E. 65513, EXP. 9/30/25N 89°31'52"E    Page 16 EXISTING PRIVATEFIRE HYDRANT EXISTING PRIVATEFIRE HYDRANT EXISTING PRIVATEFIRE HYDRANT LEGEND:ABBREVIATIONS: (XX.XX) EXISTING ELEVATIONEXISTING CONCRETE EXISTING LANDSCAPE PROP. CONCRETE PROP. LANDSCAPE EXISTING CONTOUR EXISTING WALL BOW CF ELEV ELECEX BACK OF WALK CURB FACE ELEVATION ELECTRICALEXISTING EXISTING PRIVATEFIRE HYDRANT TO BE REMOVED EXISTING PRIVATEFIRE HYDRANT FF FL FINISH FLOOR FLOW LINE FG FS GB INV MAX MHMIN MWD FINISH GRADE FINISH SURFACE GRADE BREAK INVERT MAXIMUM MANHOLEMINIMUM MUNICIPAL WATER DISTRICT XXXX PROPERTY LINE CENTERLINE OC TC TG TYP W ON CENTER TOP OF CURB TOP OF GRATE TYPICAL 150' FIRE HOSE HOSE PULL RADIUS WIDTH WM WATER METER EXFIRPARCEL 27 PARCEL MAP NO, 6194 VICINITY MAPPROPOSED BUILDING ADDITION 1109.24FF EXISTING BUILDING PROJECT DATA:N.T.S. CAL BOX WAREHOUSE EXPANSION EXISTING GROSS BLDG AREA: PROPOSED GROSS BLDG AREA: TOTAL GROSS BLDG AREA: TYPE OF CONSTRUCTION: +-99,400 SF +-47,000 SF +-146,400 SF TYPE-IIIB FULLY SPRINKLERED 150.0' HOSE PULL EXISTING PRIVATE FIRE HYDRANT EXISTING PRIVATEFIRE HYDRANT EXISTING 4" FIRESERVICE FH EX. 8" FIRE LINESERVICE DCDA BACKFLOWPREVENTER EXISTING PUBLIC FIRE HYDRANT EXISTING PRIVATE FIRE HYDRANT EXISTING 8" DCDA DRAWN BY:AM FIRE ACCESS PLAN SHEET FM-01 REVISIONS PLANS PREPARED BY:CHECKED BY: AMA DATE:09/25/23 NUMBER DATE APP'V'D BENCHMARK:CAL BOXTHE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74.8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 ELEVATION :1117.66 09/25/2023 01 OF 01BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET., AARON M. ALBERTSON R.C.E. 65513, EXP. 9/30/19N 89°31'52"E    Page 17 & & & & & & & & & & & & LEGEND(S (SMATCHLINE REFER TO SHEET MATCHLINE TAG: DESCRIPTION: ITEM: REMARKS&&#LP-02 REFER TO SHEET #LP-02 AIR MATCHLINE REFER TO SHEET #LP-02 A INFILL / EXTEND / REPAIR EXISTING TURF AND IRRIGATION BASED ON INSTALLATION OF NEW WALKWAY -&& & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & (S FF 1110.32&&&WV FH & & & & & & & & & & & & & & & & & (S REPAIR / REPLACE EXISTING LANDSCAPE AND TURF BASED ON INSTALLATION OF NEW SIDEWALK AND CURB. -BFF 1109.24 C B D (S (S C D EXISTING CANARY ISLAND PINES - PROTECT-IN-PLACE (S8" (S L&O&T L&T PLANTING AREA - INSTALL 3" DEEP LAYER OF PLANTER MULCH IN ALL SHRUB AND GROUNDCOVER AND IRRIGATION NOTES #3 THIS REFER TO GENERAL PLANTING8.0'&& & & &&AREA SHEET.&&4" P&IP&E (S FF 1110.55 EXISTING PLANTING AREA -" D E F && &&&& &(S STRUCTURAL STEEL POST ON CONCRETE PIER ON CONCRETE&&EXISTING TURF AREA - &&&(S &&PROPOSED LPG STATION RF 1145.25&&&(S G H J PEDESTRIAN CONCRETE PAVING WALKWAY ADA PATH OF TRAVEL REFER TO CIVIL ENGINEER PLANS &&&FF 1109.12 FF 1109.04 RF 1147.77&&(S &FF 1109.29&FF 1109.38&&&(S REFER TO CIVIL ENGINEER PLANS&& && & & (S&RD FF 1109.87 RF 1141.86 RF 1146.02 & &(S (S RD DRIVE ISLE OR PARKING AREA PARKING STALL REFER TO CIVIL ENGINEER PLANS& & (S & & 4" TRENCH DRN4" FIRE 8" FIRE &(S (S (S (S (S && & & &K L REFER TO CIVIL ENGINEER PLANS5F5F5F5F5F5F5F5F5F5F5F5F5F5F5F 5F5F5F5F5F5F5F5F5F5F5F5F5F5F5F 2" BFP &&5F5F5F5F5F5F5F5F5F5F5F5F5F5F 5F5F5F5F5F5F5F5F5F5F5F5F5F5F&&EXTEND EXISTING IRRIGATION TO PROVIDE PROPER COVERAGE FOR NEW LANDSCAPE AREA - - - &&5F5F5F5F5F5F5F5F5F5F5F5F5F SMH && && & && & & & & & & & & & & & & & &&&& & & & &&&& & & & & & & & & & & & & & &&M N REPAIR / REPLACE EXISTING LANDSCAPE AND IRRIGATION BASED ON INSTALLATION OF NEW CURB&&&&&&&ESCO WM && & && && &&LO& T& L&T FF 1110.16 REPAIR / REPLACE EXISTING TURF, LANDSCAPE AND IRRIGATION AS REQUIRED BASED ON INSTALLATION OF NEW ADA RAMP SMH & & &&&& & & & &&WM &&&&& &&&&& &&&&&& STLT N N D M 3/$17ꢀ6&+('8/(ꢀ/3ꢃꢂ (;,67,1*ꢀ3$/06 47<%27$1,&$/ꢀꢉꢀ&20021ꢀ1$0(5(0$5.6 (;,67,1*ꢊ6<$*586ꢀ520$1=2)),$1$ 48((1ꢀ3$/0 F F E JK G ꢂꢈ:$6+,1*721,$ꢀ52%867$ 0(;,&$1ꢀ)$1ꢀ3$/0 (;,67,1* 5(0$5.6 D L SIGNAGATE E FH B G H (;,67,1*ꢀ75((6 47< ꢊ %27$1,&$/ꢀꢉꢀ&20021ꢀ1$0(WV %5$&+<&+,721ꢀ;ꢀꢋ0$-(67,&ꢀ%($87<ꢋ 0$-(67,&ꢀ%($87<ꢀ%277/(ꢀ75(( (;,67,1* (;,67,1* (;,67,1* (;,67,1* (;,67,1* (;,67,1* 5F 5F SIGN SIGN K F FH ꢈ ꢌ &,11$02080ꢀ&$03+25$ &$03+25ꢀ75(( SMH LOT LT LOT LT /$*(56752(0,$ꢀ,1',&$ &5$3(ꢀ0<57/(LOT LT LOT LTB F GTE BX ꢇ0$*12/,$ꢀ*5$1',)/25$ 6287+(51ꢀ0$*12/,$E E E E E J ꢂꢆ ꢂ 3,186ꢀ&$1$5,(16,6 &$1$5<ꢀ,6/$1'ꢀ3,1(F E E V V 3,186ꢀ+$/(3(16,6 $//(32ꢀ3,1( PROPERTY LINE SMH PROPERTY LINE GENERAL PLANTING AND IRRIGATION NOTES:3/$17ꢀ6&+('8/(ꢀ/3ꢃꢂ 6+58%6 47<%27$1,&$/ꢀꢉꢀ&20021ꢀ1$0(:8&2/6 / 6,=(5(0$5.6 1.CONTRACTOR SHALL PROVIDE PHOTOS OF EACH VARIETY OF PLANT MATERIAL. FOR REVIEW AND APPROVAL BY OWNER AND LANDSCAPE ARCHITECT. PHOTOS SHALL SHOW THE REPRESENTATIVE SIZE, QUALITY, AND CHARACTER OF EACH VARIETY. &ꢌꢂꢌ&$5,66$ꢀ0$&52&$53$ꢀꢋ*5((1ꢀ&$53(7ꢋ *5((1ꢀ&$53(7ꢀ1$7$/ꢀ3/80 ꢂꢀ*$/ꢍ ꢅꢀ*$/ꢍ ꢅꢀ*$/ꢍ #ꢀꢊCꢁꢃꢎꢀ2ꢍ&ꢍ 2. 3. 4. 5. THE QUANTITIES SHOWN IN THE PLANTING LEGEND ARE FOR CONVENIENCE ONLY. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE AND INSTALL QUANTITIES OF PLANT MATERIAL AS DRAWN OR CALLED OUT ON THE PLAN. ꢌꢂ ꢈꢏ (/$($*186ꢀ381*(16 7+251<ꢀ(/$($*186 /ꢀꢉꢀ0 / #ꢀꢆCꢁꢃꢎꢀ2ꢍ&ꢍ #ꢀꢏCꢁꢃꢎꢀ2ꢍ&ꢍ RAIL ROAD (S THE CONTRACTOR SHALL INSTALL A 3" DEEP LAYER OF PLANTER MULCH IN ALL SHRUB AND GROUNDCOVER AREAS. SUBMIT SAMPLE AND TECHNICAL INFORMATION TO LANDSCAPE ARCHITECT FOR REVIEW AND APPROVAL. NEW WATER EFFICIENT LANDSCAPE IRRIGATION SYSTEM ON AUTOMATED TIMERS AND SENSORS SHALL BE USED AND ABIDE BY ALL APPLICABLE CITY OF RANCHO CUCAMONGA WATER USE PROHIBITIONS. CONTRACTOR SHALL NOTIFY THE OWNER OF ANY CONCERNS ABOUT THE EXISTING IRRIGATION SYSTEM AND RECOMMENDATIONS FOR REQUIRED IMPROVEMENTS. 5+$3+,2/(3,6ꢀ,1',&$ꢀꢋ&/$5$ꢋ &/$5$ꢀ,1',$1ꢀ+$:7+2515F NORTH AREA SOUTH AREA Under Ground Service Alert of Southern California0102040 CONTACT811 KEY MAPScale: 1"=20'TWO WORKING DAYS BEFORE YOU DIG N.T.S. DRAWN BY: CHECKED BY: BH DATE: 09/25/23 APP'V'D BENCHMARK: PC /$1'6&$3(ꢀ&21&(37ꢀ3/$17,1*ꢀ3/$1ꢀꢁꢀ6287+SHEETREVISIONS%UDQGRQꢀ+DQQD 09/25/2023 BRANDON HANNA, RLA EXP. 9/30/25 DATENUMBERDATE /3ꢁ2ꢂ 2 OF 03 09/25/23 AGENCY SUBMITTAL THE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74. %UDQGRQꢀ+DQQD 8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 ELEVATION : 1117.66 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET., 16672 Millikan Avenue T: (949) 224-0040 www.missionlandscape.comIrvine, CA 92606N 89°31'52"E    Page 18 LEGEND TAG: DESCRIPTION: ITEM: REMARKS GTE MH A NOT ASSIGNED - SD M B REPAIR / REPLACE EXISTING LANDSCAPE BASED ON INSTALLATION OF NEW SIDEWALK AND CURB. - RAILROAD SPUR PP C D EXISTING CANARY ISLAND PINES - PROTECT-IN-PLACEFH WV PP PLANTING AREA - INSTALL 3" DEEP LAYER OF PLANTER MULCH IN ALL SHRUB AND GROUNDCOVER AND IRRIGATION NOTES #3 THIS AREA REFER TO GENERAL PLANTINGEDIS K RA FH SHEET. EXISTING PLANTING -E CONCRETE SWALE NOT ASSIGNED -F G H J P PEDESTRIAN CONCRETE PAVING WALKWAY NOT ASSIGNED REFER TO CIVIL ENGINEER PLANS V D GAT GA E &(S (S (S (S (S (S (S 285.4'& &FF 1110.86 FF 1111.43 DRIVE ISLE OR PARKING AREA PARKING STALL REFER TO CIVIL ENGINEER PLANS&& & & & & & & & & & FF 1111.86&&FF 1111.40& & & & & & & & & & REFER TO CIVIL ENGINEER PLANS&& & & & & & K L& & & & & & & & NOT ASSIGNED -B O G NOT ASSIGNED -M N O P FIRE SERVICE E NOT ASSIGNED -LOADING DOCK& &&&&P NEW STEPS WITH HANDRAIL EXISTING RETAINING WALL REFER TO CIVIL ENGINEER PLANS - FF 1111.75 & & & & & & & & & &(S (S (S B C & & & & & & & & & & FF 1110.20 FF 1110.12 UTILITY MH CO G & & & & & & & & & & & & & & & & & & & & & &&& LO&T LT& (S& & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & & (S (S (S (S (S (S (S (S (S (S (S (S (S (S (S (S (S (S (S (S (S STRUCTURAL STEEL POST ON CONCRETE WV FH FF 1109.99J K 4" FIRE COMMERCIAL BUILDING& & & & & & & & & & & & & & & & & & & & & & & & & & & FF 1111.30 CO & & & & & & & & & & & & & & PARCEL 27 PARCEL MAP NO, 6194C D FF 1109.74 3/$17ꢀ6&+('8/(ꢀ/3ꢃꢌ (;,67,1*ꢀ75((6 47<%27$1,&$/ꢀꢉꢀ&20021ꢀ1$0(5(0$5.6 (;,67,1*ꢌ%5$&+<&+,721ꢀ;ꢀꢋ0$-(67,&ꢀ%($87<ꢋ 0$-(67,&ꢀ%($87<ꢀ%277/(ꢀ75(( FIRE SERVICE ꢂꢆ3,186ꢀ&$1$5,(16,6 &$1$5<ꢀ,6/$1'ꢀ3,1( (;,67,1* B O G STRUCTURAL STEEL POST ON CONCRETE PIER ON CONCRETE AIR E RAIL ROAD& &&&&&AIR NORTH AREA&M&AT&CH&LIN&E && & (S (S MATCHLINE REFER TO SHEET # LP-01 FF 1110.3 WV FHMATCHLINE REFER TO SHEET # LP-01 REFER TO SHEET #LP-01 && &&&&FF 1109 24 3/$17ꢀ6&+('8/(ꢀ/3ꢃꢌSOUTH AREA6+58%6 47<%27$1,&$/ꢀꢉꢀ&20021ꢀ1$0(:8&2/6 / 6,=(5(0$5.6 ꢌꢈꢏ&$5,66$ꢀ0$&52&$53$ꢀꢋ*5((1ꢀ&$53(7ꢋ *5((1ꢀ&$53(7ꢀ1$7$/ꢀ3/80 ꢂꢀ*$/ꢍ#ꢀꢊCꢁꢃꢎꢀ2ꢍ&ꢍ&Under Ground Service Alert0102040of Southern California ꢏꢌ(/$($*186ꢀ381*(16 7+251<ꢀ(/$($*186 /ꢀꢉꢀ0 ꢅꢀ*$/ꢍ#ꢀꢆCꢁꢃꢎꢀ2ꢍ&ꢍCONTACT(S 811 KEY MAPScale: 1"=20'TWO WORKING DAYS BEFORE YOU DIG N.T.S. DRAWN BY:PC /$1'6&$3(ꢀ&21&(37ꢀSHEETREVISIONSCHECKED BY: BH %UDQGRQꢀ+DQQD 3/$17,1*ꢀ3/$1ꢀꢁꢀ1257+09/25/2023 BRANDON HANNA, RLA EXP. 9/30/25 DATEDATE:09/25/23 NUMBER DATE 09/25/23 AGENCY SUBMITTAL APP'V'D BENCHMARK: THE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74. %UDQGRQꢀ+DQQD 8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 /3ꢁ2ꢌ 2 OF 03ELEVATION : 1117.66 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET., 16672 Millikan Avenue T: (949) 224-0040 www.missionlandscape.comIrvine, CA 92606N 89°31'52"E    Page 19 CARISSA MACROCARPA 'GREEN CARPET' DWARF NATAL PLUM ELAEAGNUS PUNGENS THORNY ELAEAGNUS RHAPHIOLEPIS INDICA 'CLARA' INDIAN HAWTHORN DRAWN BY:PC /$1'6&$3(ꢀ&21&(37ꢀ3/$17,1*ꢀ,0$*(5<SHEETREVISIONSCHECKED BY: BH %UDQGRQꢀ+DQQD BRANDON HANNA, RLA EXP. 9/30/25 09/25/2023 DATEDATE:09/25/23 NUMBER DATE 09/25/23 AGENCY SUBMITTAL APP'V'D BENCHMARK: THE BENCHMARK FOR THIS SURVEY ARE THE FIELD NOTES FOR THE M.W.D. WATER LINE, PROJECT NAME CLEVELAND AVE, IN BOOK 4014, PAGE 700 DATED 10-7-74. %UDQGRQꢀ+DQQD 8949 TORONTO AVENUE RANCHO CUCAMONGA, CA 91730 APN: 0209-401-05-0000 /3,ꢁ2ꢂ 3 OF 03ELEVATION : 1117.66 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS SURVEY IS THE NORTHERLY LINE OF PARCEL MAP NO. 6194 ALSO CALLED OUT AS EIGHT STREET., 16672 Millikan Avenue Irvine, CA 92606 T: (949) 224-0040 www.missionlandscape.comN 89°31'52"E    Page 20 ꢂꢃꢄꢅꢆ 6,7(ꢀ3/$1ꢀ/(*(1' 127ꢀ,1ꢀ6&23( 6,7(ꢀ:$/.ꢀ3$9,1* ꢇꢉꢇꢉꢀ6DQꢀ)HOLSHꢀ6Wꢐꢀ6XLWHꢀꢉꢏꢅꢅ +RXVWRQꢃꢀ7;ꢀꢀꢏꢏꢅꢇꢆ ꢏꢉꢈꢋꢆꢆꢅꢋꢆꢉꢅꢎ/$1'6&$3,1*ꢀꢌꢀ*5$66 ZZZꢐJRUHHꢐFRP'(6,*1$7('ꢀ),5(ꢀ$&&(66ꢀ/$1( &2168/7$176 :$5(+286(ꢀꢌꢀ6725$*(ꢀꢋ ꢆꢇꢃꢉꢎꢆꢀ6)&,9,/ &'5( ' & % $ ꢆꢁꢇꢀ72:1ꢀ&(17(5ꢀ'5,9(ꢃꢀ68,7(ꢀꢉꢉꢅ &267$ꢀ0(6$ꢃꢀ&$ꢀꢁꢎꢆꢎꢆ ꢁꢄꢁꢋꢈꢇꢉꢋꢇꢈꢎꢇ 0$18)$&785,1*ꢀ(48,30(17ꢀꢋ ꢉꢇꢃꢂꢎꢅꢀ6) :::ꢐ&'5:(67ꢐ&20,1'8675,$/ꢀ0$18)$&785,1*ꢀꢋ ꢎꢅꢃꢄꢇꢉꢀ6) 2)),&(ꢀ63$&(ꢀꢋ ꢇꢃꢇꢂꢇꢀ6) 6758&785$/ '$//<ꢈ$662&,$7(6 ꢁꢂꢅꢅꢀ5,&+021'ꢀ$9(18(ꢃꢀ68,7(ꢀꢄꢆꢅ +286721ꢃꢀ7;ꢀꢏꢏꢅꢄꢎ ꢏꢉꢈꢋꢈꢈꢏꢋꢂꢂꢂꢉ '$//<$662&,$7(6ꢐ&20 3523(57<ꢀ/,1(ꢇꢈꢉꢊꢀꢋꢀꢁꢀꢉꢌꢄꢍ3523(57<ꢀ/,1( 75$,/(5ꢀ3$5.,1*0(3 *.ꢉ(1*,1((56 ꢇꢁꢇꢁꢀ:ꢀ/223ꢀ6ꢃꢀ68,7(ꢀꢈꢇꢅ %(//$,5ꢃꢀ7;ꢀꢏꢏꢄꢅꢉ ꢏꢉꢈꢋꢁꢂꢂꢋꢂꢂꢁꢄ)+352326('ꢀ),5(ꢀ+<'5$17 +26(ꢀ/$< *.ꢋ0(3ꢐ&20 3523(57<ꢀ/,1( ꢆꢈꢊꢀꢋꢀꢆꢍ '183 6,7(ꢀ3/$1ꢀ*(1(5$/ꢀ127(6 ꢈꢀ36 (;,67,1*ꢀ7,/7:$// %8,/',1*3523(57<ꢀ/,1(352-(&7ꢀ1$0( ꢁꢂꢃꢄꢅꢆꢀ6)&$/ꢀ%2;ꢀ,, :$5(+286( (;3$16,21 :$5(+286(ꢀꢌꢀ6725$*(ꢀꢋ ꢆꢇꢃꢉꢎꢆꢀ6) 0$18)$&785,1*ꢀ(48,30(17ꢀꢋ ꢉꢇꢃꢂꢎꢅꢀ6) ,1'8675,$/ꢀ0$18)$&785,1*ꢀꢋ ꢎꢅꢃꢄꢇꢉꢀ6) 2)),&(ꢀ63$&(ꢀꢋ ꢇꢃꢇꢂꢇꢀ6)352-(&7ꢀ'(6&5,37,21 $'',7,21ꢀ2)ꢀ(;,67,1* :$5(+286(75$,/(5ꢀ3$5.,1* ꢁꢀ36 352-(&7ꢀ$''5(66 ꢂꢁꢄꢁꢀ7252172ꢀ$9(18(ꢃ 5$1&+2ꢀ&8&$021*$ꢃ &$ꢃꢁꢉꢏꢈꢅ 352326('ꢀ7,/7:$// (;3$16,21 ꢄꢇꢃꢁꢁꢈꢀ6) 180%(5ꢀ2)ꢀ3$5.,1*ꢀ63$&(6ꢀ5(48,5('ꢀ3(5ꢀ7$%/(ꢀꢉꢏꢐꢆꢄꢐꢅꢇꢅꢀꢋ 3$5.,1*ꢀ5(48,5(0(176ꢀ%<ꢀ/$1'ꢀ86(2:1(5ꢀ,1)250$7,21 &$/ꢀ%2;ꢀ,,ꢎꢅꢊꢀꢋꢀꢅꢍ(;,67,1*ꢀ:$5(+286(ꢀꢌꢀ 6725$*(ꢀ ꢉꢀ3(5ꢀꢉꢃꢅꢅꢅꢀ6)ꢀ)25ꢀ),567ꢀꢎꢅꢃꢅꢅꢅꢀ 6)ꢑꢀꢉꢀ3(5ꢀꢎꢃꢅꢅꢅꢀ6)ꢀ)25ꢀ1(;7ꢀ ꢎꢅꢃꢅꢅꢅꢀ6)ꢑꢀ$1'ꢀꢉꢀ3(5ꢀꢄꢃꢅꢅꢅꢀ6)ꢀ )25ꢀ7+(ꢀ5(0$,1,1*ꢀ6)ꢐ ꢆꢇꢃꢉꢎꢆꢀꢋ ),567ꢀꢎꢅꢃꢅꢅꢅꢀ ꢀꢎꢅꢀ36 ꢄꢇꢃꢉꢎꢇꢀꢋ 6(&21'ꢀꢎꢅꢃꢅꢅꢅꢀ ꢀꢉꢅꢀ36 ꢎꢇꢃꢉꢎꢇꢀ5(0$,1,1*ꢀ ꢀꢆꢀ36 ꢈꢆꢀ36ꢀ727$/ ,1'8675,$/ꢀ0$18)$&785,1* 2)),&(ꢀ63$&( ꢎꢀ3(5ꢀꢉꢃꢅꢅꢅꢀ6) ꢄꢀ3(5ꢀꢉꢃꢅꢅꢅꢀ6) ꢉꢀ3(5ꢀꢄꢃꢅꢅꢅꢀ6)ꢀ ꢉꢉꢃꢏꢏꢁꢀ6)ꢀ ꢀꢎꢄꢀ36ꢀ727$/ ꢇꢃꢇꢂꢇꢀ6)ꢀ ꢀꢎꢎꢀ36ꢀ727$/ ꢄꢄꢃꢂꢉꢅꢀ6) ꢀꢉꢎꢀ36ꢀ727$/352326('ꢀ :$5(+286(ꢀꢌꢀ6725$*(ꢀꢁꢀ36 727$/ꢀ3$5.,1*ꢀ63$&(6ꢀꢒ36ꢓꢀ5(48,5(' 727$/ꢀ3$5.,1*ꢀ63$&(6ꢀꢒ36ꢓꢀ3529,'(' ꢁꢄꢀ36ꢀ727$/ ꢉꢅꢈꢀ36ꢀ727$/ ꢆꢅꢊꢀꢋꢀꢎꢀꢉꢌꢂꢍ ꢈꢀ36 6,7(ꢀ3/$1ꢀ.(<('ꢀ127(6 *25((ꢀ352-(&7ꢀ180%(5 &ꢎꢎꢅꢁꢆ '1 67$03ꢀꢌꢀ6,*1$785( 5/3(*/2ꢀ6& 7 $ $ 7 7 ('ꢀ ,21 ꢇꢊꢀꢋꢀꢅꢍꢉꢄꢊꢀꢋꢀꢅꢍ6,7(ꢀ3/$1ꢀ.(<('ꢀ127(6 $ꢀ $6ꢀꢁꢂ7<3( &86720(5 (03/2<(( 6(59,&( 63$&(6 '1 ꢉꢇ ꢉꢇ ꢏꢅ ꢎ (;,67,1* ꢀ),5(ꢀ/$1( ,668(ꢀ+,6725<$'$ꢀ3$5.,1* 727$/ '$7(ꢔ ꢅꢆꢌꢉꢂꢌꢎꢅꢎꢄ 0$5.ꢔ'(6&5,37,21ꢔ '(6,*1ꢀ5(9,(:ꢉꢅꢎ '6&(&2255('$7ꢀ&,92(1ꢀ3&$59(,17(* 3523(57<ꢀ/,1( 3$5.,1*ꢀ$1$/<6,6 ꢁꢅꢊꢀꢋꢀꢆꢍ ꢇꢀ36 ꢆꢀ36 ꢉꢎꢀ36 3523(57<ꢀ/,1( ꢂꢅꢊꢀꢋꢀꢉꢉꢍꢂꢉꢊꢀꢋꢀꢆꢀꢈꢌꢂꢍꢁꢅꢊꢀꢋꢀꢎꢀꢈꢌꢂꢍ .(<ꢀ3/$1 ++++++ 6+((7ꢀ1$0( $5&+,7(&785$/ꢀ6,7(ꢀ3/$1 1 6+((7ꢀ180%(5 $6ꢂꢇꢂ29(5$//ꢀ6,7(ꢀ3/$1 6&$/(ꢔ ꢂꢊꢄꢃꢋꢀ ꢀꢂꢌꢉꢇꢋ$ꢉ ꢂꢃꢄꢅꢆ    Page 21 ￿￿￿￿￿￿ ￿￿￿￿￿6DQ￿)HOLSH￿6W￿￿6X LWH￿￿￿￿￿ +RXVWRQ￿￿7;￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ZZZ￿JRUHH￿FRP &2168/7$176 &,9,/ &'5( ' & % $ ( ' & % $ ￿￿￿￿72:1￿&(17(5￿'5,9(￿￿68,7(￿￿￿￿ &267$￿0(6$￿￿&$￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ :::￿&'5:(67￿&20 6758&785$/ '$//<￿$662&,$7(6 ￿￿￿￿￿5,&+021'￿$9(18(￿￿68,7(￿￿￿￿ +286721￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ '$//<$662&,$7(6￿&20 0(3 *.￿(1*,1((56 ￿￿￿￿￿:￿/223￿6￿￿68,7(￿￿￿￿ %(//$,5￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ *.￿0(3￿&20 352-(&7￿1$0( &$/￿%2;￿,, :$5(+286( (;3$16,21 352-(&7￿'(6&5,37,21 $'',7,21￿2)￿(;,67,1* :$5+286( 352-(&7￿$''5(66 ￿￿￿￿￿7252172￿$9(18(￿ 5$1&+2￿&8&$021*$￿ &$￿￿￿￿￿￿ 2:1(5￿,1)250$7,21 &$/￿%2;￿,, (;,67,1*￿*$7( *25((￿352-(&7￿180%(5 &￿￿￿￿￿ 67$03￿￿￿6,*1$785( $￿ $6￿￿￿,668(￿+,6725< '$7(￿0$5.￿'(6&5,37,21￿ '(6,*1￿5(9,(:￿￿￿￿￿￿￿￿ ￿￿ '(&25$7,9(￿3$9,1* 6&25('￿&21&5(7( .(<￿3/$1 $''('￿5(48,5('￿￿￿￿3(5&(17￿9,(: 2%6&855,1*￿0(7$/￿%$&.,1*￿ (;,67,1*￿(175$1&(￿*$7( (;,67,1*￿)(1&( &$/￿%2;￿,, ￿￿￿￿6+((7￿1$0( 6,7(￿'(7$,/6 6+((7￿180%(5 $6￿￿￿29(5$//￿6,7(￿3/$1￿￿ (175$1&(￿*$7( 6&$/(￿ ￿￿￿￿￿ ￿￿￿￿￿￿ (175$1&(￿*$7( $￿$￿6&$/(￿ ￿￿￿￿￿ ￿￿￿￿￿￿ ￿￿￿￿￿￿    Page 22 ￿￿￿￿￿ )/225￿3/$1￿/(*(1' 127￿,1￿&2175$&7 %8,/',1*￿&25(￿(/(0(176 ￿￿￿￿￿6DQ￿)HOLSH￿6W￿￿6X LWH￿￿￿￿￿ +RXVWRQ￿￿7;￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ (;,67,1*￿0,//:25.￿72￿5(0$,1 ,1',&$7(6￿0,//:25.￿72￿%(￿'(02/,6+('ZZZ￿JRUHH￿FRP (;,67,1*￿&216758&7,21￿72￿5(0$,1 &2168/7$176 (;,67,1*￿&216758&7,21￿72￿%(￿'(02/,6+('￿&,9,/ &'5( ' & % $ ￿￿￿￿72:1￿&(17(5￿'5,9(￿￿68,7(￿￿￿￿ &267$￿0(6$￿￿&$￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ (;,67,1*￿'225￿72￿5(0$,1 (;,67,1*￿'225￿72￿%(￿5(029(':::￿&'5:(67￿&20 6758&785$/ '$//<￿$662&,$7(6 ￿￿￿￿￿5,&+021'￿$9(18(￿￿68,7(￿￿￿￿ +286721￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ '$//<$662&,$7(6￿&20 )/225￿3/$1￿*(1(5$/￿127(6 $￿ *&￿72￿),(/'￿9(5,)<￿&21',7,216￿%()25(￿352&((',1*￿$1'￿,1)250￿$5&+,7(&7 $1'￿7(1$176￿5(35(6(17$7,9(￿2)￿$1<￿',6&5(3$1&,(6￿ 0(3 *.￿(1*,1((56 ￿￿￿￿￿:￿/223￿6￿￿68,7(￿￿￿￿ %(//$,5￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ %￿ $//￿',0(16,216￿$5(￿72￿)$&(￿2)￿*:%￿￿(;&/86,9(￿2)￿$33/,('￿),1,6+(6￿ 7<3,&$/￿81/(66￿127('￿27+(5:,6(￿ &￿ ,1￿',0(16,21￿675,1*6￿￿$￿￿￿￿￿￿￿￿,1',&$7(6￿$￿',0(16,21￿72￿%(￿),(/'￿9(5,),(' $)7(5￿7+(￿5(0$,1'(5￿2)￿7+(￿675,1*￿,6￿/$,'￿287￿￿￿127,)<￿$5&+,7(&7￿2)￿$1< 6,*1,),&$17￿',0(16,21$/￿',6&5(3$1&,(6￿*5($7(5￿7+$1￿￿￿￿ *.￿0(3￿&20 ￿￿￿(;￿(;￿'￿(;￿(;￿(;￿(;￿(;￿$￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ '1 ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿'￿ $//￿:22'￿%/2&.,1*￿6+$//￿%(￿),5(￿5(7$5'$17￿75($7('￿72￿&21)250￿72￿7+( ),5(￿5(6,67,9(￿67$1'$5'6￿2)￿7+(￿/2&$/￿-85,6',&7,21￿+$9,1*￿$87+25,7<￿ 83 (;$(￿ $//￿)/2256￿6+$//￿%(￿/(9(/('￿72￿￿￿￿￿￿,1￿￿￿￿￿￿￿25￿72￿,1'8675<￿67$1'$5'￿ )/2256￿6+$//￿%(￿),//('￿$1'￿6:(37￿%5220￿&/($1￿)￿ *&￿72￿9(5,)<￿&21',7,21￿2)￿(;,67,1*￿:,1'2:￿75($70(176￿￿5(3/$&(￿'$0$*(' 25￿0,66,1*￿:,7+￿1(:￿72￿0$7&+￿￿$//￿:,1'2:￿75($70(176￿$5(￿72￿%( &216,67(17￿:,7+,1￿($&+￿5220￿83 3$57,7,216 *￿ 5()(5￿72￿6+((7￿;;;;￿)25￿3$57,7,21￿7<3(6￿$1'￿$'',7,21$/￿127(6 +￿ $//￿1(:￿3$57,7,216￿$5(￿6+2:1￿6+$'('￿$1'￿￿81/(66￿127('￿27+(5:,6(￿21 3/$1￿￿$5(￿7<3(￿￿$￿￿￿￿25￿￿(￿￿￿￿5()(5￿72￿/(*(1'￿)25￿6+$',1*￿7<3(6￿￿￿￿2 7+(5 3$57,7,21￿7<3(￿:+,&+￿0$<￿%(￿&$//('￿287￿21￿7+(￿3/$1￿683(56('(￿7+( 6+$',1*￿6+2:1￿$7￿7+$7￿/2&$7,21￿￿￿5()(5￿72￿7+,6￿6+((7￿21/<￿)25￿:$// 6+$',1*￿7<3(6￿,￿ :+(5(￿1(:￿3$57,7,216￿-2,1￿(;,67,1*￿￿&2175$&725￿72￿9(5,)<￿(;,67,1* 3$57,7,21￿7+,&.1(66￿$1'￿0$7&+￿1(:￿72￿(;,67,1*￿ -￿ 9(5,)<￿(;,67,1*￿&20021￿&255,'25￿$1'￿$'-$&(17￿7(1$17￿:$//6￿(;7(1'￿72 81'(56,'(￿2)￿6758&785(￿$%29(￿￿￿,)￿127￿￿(;7(1'￿(;,67,1*￿:$//6￿72 6758&785(￿$%29(￿￿5(￿￿3$57,7,21￿7<3(￿￿.￿￿(;% (;& (;' (;( (;) (;* 352-(&7￿1$0( .￿ $//￿,17(5,25￿*/$=,1*￿6<67(06￿72￿%(￿085$)/(;￿),12￿￿8￿1￿2￿￿&217$&7￿)5$1. %5812￿#￿7(;$6￿,17(5,256￿)25￿35,&,1*￿ &$/￿%2;￿,, :$5(+286( (;3$16,21 352326('￿7,/7:$// (;3$16,21 (;,67,1*￿7,/7:$// %8,/',1* ￿￿￿￿￿￿￿6 ) ￿￿￿￿￿￿￿6 )'2256 /￿ 5()(5￿72￿6+((7￿;;;;￿)25￿'225￿￿)5$0(￿$1'￿+$5':$5(￿6&+('8/(6￿$1' 5(63216,%,/,7,(6￿$1'￿$'',7,21$/￿127(6￿￿￿&225',1$7(￿:,7+￿),1,6+(6 63(&,),&$7,216￿￿$//￿'225￿-$0%6￿72￿%(￿6(7￿￿￿￿)520￿,17(56(&7,1*￿3$57,7,216￿ 7<3,&$/￿￿812￿ 352-(&7￿'(6&5,37,21 $'',7,21￿2)￿(;,67,1* :$5+286(0￿ $//￿1(:￿25￿5(86('￿'2256￿$1'￿)5$0(6￿72￿0$7&+￿(;,67,1*￿'2256￿$1' )5$0(6￿:,7+,1￿/($6(￿63$&(￿￿812￿￿(9$/8$7(￿'2256￿)25￿5(86(￿￿*&￿72￿728&+ 83￿$6￿5(48,5('￿72￿%(,1*￿72￿/,.(￿1(:￿&21',7,21￿￿$//￿'2256￿:,7+￿/2&.6(76 127￿86('￿72￿%(￿3$7&+('￿:,7+￿0(7$/￿%/$1.6￿,)￿1(&(66$5<￿￿,)￿'225 81'(5&876￿(;&(('￿￿￿￿￿￿$))￿￿*&￿6+$//￿&217$&7￿$5&+,7(&7￿,1￿25'(5￿72 '(7(50,1(￿,)￿&255(&7,9(￿$&7,21￿,6￿5(48,5('￿ 352-(&7￿$''5(66 ￿￿￿￿￿7252172￿$9(18(￿ 5$1&+2￿&8&$021*$￿ &$￿￿￿￿￿￿ 1￿ $//￿+$5':$5(￿6+$//￿%(￿/(9(5￿7<3(￿￿812￿￿*&￿72￿9(5,)<￿&203/(7(1(66￿2)￿$// /$7&+￿6(76￿$1'￿/2&.￿6(76￿)25￿5(86(￿$1'￿3529,'(￿0,66,1*￿&20321(176￿$6 5(48,5('￿ 3/80%,1*2:1(5￿,1)250$7,21 &$/￿%2;￿,,2￿ *&￿72￿9(5,)<￿23(5$7,21$/￿&21',7,21￿2)￿$//￿(;,67,1*￿3/80%,1*￿72￿5(0$,1 $1'￿&21',7,21￿2)￿$662&,$7('￿0,//:25.￿$1'￿5(3$,5￿$6￿5(48,5('￿ 3￿ $//￿1(:￿)$8&(76￿72￿%(￿(48,33('￿:,7+￿$'$￿$33529('￿:5,67￿%/$'(6￿81/(66 +$1'6￿)5((￿'(9,&(￿,6￿63(&,),('￿ 4￿ $//￿3/80%,1*￿,1￿5(7851￿$,5￿3/(180￿72￿%(￿&$67￿,521￿$6￿3(5￿/2&$/ -85,6',&7,21￿￿+$9,1*￿$87+25,7<￿ &￿ $￿￿￿0,//:25. 5￿ *&￿72￿(;$0,1(￿&21',721￿2)￿$//￿(;,67,1*￿0,//:25.￿$1'￿5(3$,5￿72 $&&(37$%/(￿&21',7,21￿ 6￿ 6&5,%(￿$//￿0,//:25.￿72￿$'-$&(17￿685)$&(6￿$6￿5(48,5('￿ 7￿ 3529,'(￿),5(￿5(7$5'$17￿%/2&.,1*￿,1￿3$57,7,216￿$7￿:$//￿02817(' (48,30(17￿$1'￿0,//:25.￿ 8￿ :+(1￿0,//:25.￿$%8776￿$￿3$57,7,21￿￿7+(￿3$57,7,21￿6+$//￿(;7(1'￿￿￿￿%(<21' 7+(￿('*(￿2)￿7+(￿0,//:25.￿ )/9￿22&21755$￿&3725/￿7$2￿01$7&￿+.￿6,(/,&<21((￿&'￿51￿722￿0,/7/:(25.￿),1,6+(6￿6 *25((￿352-(&7￿180%(5 &￿￿￿￿￿ 67$03￿￿￿6,*1$785( ,668(￿+,6725< '$7(￿0$5.￿'(6&5,37,21￿ '(6,*1￿5(9,(:￿￿￿￿￿￿￿￿ ￿￿ *￿￿(;,67,1*￿ 2)),&(6 5￿5￿ 5￿5￿ $￿ $￿￿￿ '1 ￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿ (;+ (;, $/,*1 .(<￿3/$1 ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿￿￿￿ ￿￿￿￿ '1 ￿￿￿￿￿￿￿￿ ￿￿￿￿ &/&/&/ %￿ $￿￿￿1 6+((7￿1$0( 29(5$//￿)/225￿3/$1 6+((7￿180%(51$￿￿￿29(5$//￿)/225￿3/$1 6&$/(￿ ￿￿￿￿￿￿ ￿￿￿￿￿￿$￿ ￿￿￿￿￿    Page 23 ￿￿￿￿￿ 522)￿3/$1￿/(*(1' '(127(6￿578￿=21( '(127(6￿7$3(5('￿,168/$7,21 ￿￿￿￿￿￿￿3(5￿)7￿6/23(￿￿￿￿￿6DQ￿)HOLSH￿6W￿￿6X LWH￿￿￿￿￿ +RXVWRQ￿￿7;￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ )8785(￿3$5.,1* 35(),1,6+('￿￿￿35()$%5,&$7('￿ $12',=('￿$/80,180￿&$123<ZZZ￿JRUHH￿FRP 723￿ ￿723￿2)￿3$5$3(7 '6￿ ￿5(&(66('￿'2:163287 &2168/7$176 &,9,/ &'5( ' & % $ 522)￿3/$1￿*(1(5$/￿127(6 ￿￿￿￿72:1￿&(17(5￿'5,9(￿￿68,7(￿￿￿￿ &267$￿0(6$￿￿&$￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ :::￿&'5:(67￿&20 $￿ *&￿72￿&225',1$7(￿:,7+￿0(&+$1,&$/￿6&5((1￿0$18)$&785(5￿21￿/2&$7,21￿2) 0(&+$1,&$/￿6&5((1￿32676￿￿5()(5￿72￿6758&785$/￿)25￿%5$&,1*￿6758&785$/ '$//<￿$662&,$7(6 ￿￿￿￿￿5,&+021'￿$9(18(￿￿68,7(￿￿￿￿ +286721￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ '$//<$662&,$7(6￿&20 %￿ 5()(5￿72￿0(&+$1,&$/￿￿(/(&75,&$/￿$1'￿3/80%,1*￿)25￿27+(5￿522)￿(48,30(17￿ &￿ 3/$&(￿522)￿:$/.￿3$'￿$7￿3(5,0(7(5￿2)￿0(&+$1,&$/￿(48,30(17￿￿522) +$7&+(6￿$1'￿75$9(/￿5287(6￿)520￿522)￿/$''(56￿ 0(3 *.￿(1*,1((56 ￿￿￿￿￿:￿/223￿6￿￿68,7(￿￿￿￿ %(//$,5￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ 522)￿3/$1￿.(<('￿127(6 ￿￿￿(;￿(;￿(;￿(;￿(;￿(;￿(;￿*.￿0(3￿&20 (;$ (;% (;& (;' (;( (;) (;* 352-(&7￿1$0( &$/￿%2;￿,, :$5(+286( (;3$16,21 352-(&7￿'(6&5,37,21 $'',7,21￿2)￿(;,67,1* :$5+286( 352-(&7￿$''5(66 ￿￿￿￿￿7252172￿$9(18(￿ 5$1&+2￿&8&$021*$￿ &$￿￿￿￿￿￿ 2:1(5￿,1)250$7,21 &$/￿%2;￿,, (;,67,1*￿7,/7:$// %8,/',1* *25((￿352-(&7￿180%(5 &￿￿￿￿￿ 67$03￿￿￿6,*1$785( ,668(￿+,6725< '$7(￿0$5.￿'(6&5,37,21￿ '(6,*1￿5(9,(:￿￿￿￿￿￿￿￿ ￿￿ ￿￿￿￿￿ ￿￿*￿￿ (;+ (;, .(<￿3/$1 1 6+((7￿1$0( 29(5$//￿522)￿3/$1 6+((7￿180%(5 1 $￿￿￿29(5$//￿522)￿3/$1 6&$/(￿ ￿￿￿￿￿￿ ￿￿￿￿￿￿$￿ ￿￿￿￿￿    Page 24 ￿￿￿￿￿￿ (;7(5,25￿0$7(5,$/￿/(*(1' 62/,'￿￿ :+,7(￿￿ *(1(5$/￿3$,17￿29(5￿&21&5(7( )250/,1(5￿￿ 9(57,&$/￿￿￿￿￿￿6DQ￿)HOLSH￿6W￿￿6X LWH￿￿￿￿￿ +RXVWRQ￿￿7;￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ */$=,1*￿￿ 9,6,21 ZZZ￿JRUHH￿FRP (;,67,1*￿%8,/',1* &2168/7$176 &,9,/ &'5( ' & % $ ( ' & % $ ￿￿￿￿72:1￿&(17(5￿'5,9(￿￿68,7(￿￿￿￿ &267$￿0(6$￿￿&$￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿(/(9$7,21￿.(<('￿127(6 :::￿&'5:(67￿&20 6758&785$/ '$//<￿$662&,$7(6 ￿￿￿￿￿5,&+021'￿$9(18(￿￿68,7(￿￿￿￿ +286721￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ '$//<$662&,$7(6￿&20 0(3 *.￿(1*,1((56 ￿￿￿￿￿:￿/223￿6￿￿68,7(￿￿￿￿ %(//$,5￿￿7;￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿ (;￿(;￿(;￿(;￿(;￿(;￿(;￿￿￿￿*.￿0(3￿&20 ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿3$5$3(7￿% ￿￿￿￿￿ ￿￿ 3$5$3(7￿$ ￿￿￿￿￿ ￿￿ *5281'￿)/225 ￿￿ 352-(&7￿1$0(758&.￿&2857 ￿￿￿￿￿ ￿￿29(5$//￿1257+￿(/(9$7,21 6&$/(￿ ￿￿￿￿￿￿ ￿￿￿￿￿￿ &$/￿%2;￿,, :$5(+286( (;3$16,21 '￿ (;$(;%(;&(;'(;((;)(;**￿￿(;+ 352-(&7￿'(6&5,37,21 ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿$'',7,21￿2)￿(;,67,1* :$5+286(￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿352-(&7￿$''5(66 3$5$3(7￿% ￿￿￿￿￿ ￿￿ ￿￿￿￿￿7252172￿$9(18(￿ 5$1&+2￿&8&$021*$￿ &$￿￿￿￿￿￿3$5$3(7￿$ ￿￿￿￿￿ ￿￿ 2:1(5￿,1)250$7,21 &$/￿%2;￿,, *5281/'(￿)/2/2￿￿5￿ ￿￿ 29(5$//￿:(67￿(/(9$7,21&￿6&$/(￿ ￿￿￿￿￿￿ ￿￿￿￿￿￿ ￿￿￿(;￿(;￿(;￿(;￿(;￿(;￿(;￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿&/ ￿￿￿￿￿￿￿ ￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿ ￿￿￿￿￿ ￿￿￿0$7&+￿(;,67,1*￿￿￿￿￿ ￿￿*25((￿352-(&7￿180%(5 &￿￿￿￿￿3$5$3(7￿% ￿￿￿￿￿ ￿￿67$03￿￿￿6,*1$785( 3$5$3(7￿$ ￿￿￿￿￿ ￿￿ ,668(￿+,6725< *5281/'(￿)9 /(2/2￿ ￿5￿'$7(￿0$5.￿'(6&5,37,21￿ '(6,*1￿5(9,(:￿￿￿￿￿￿￿￿￿￿ ￿￿ 758&.￿&2857 ￿￿￿￿￿ ￿￿29(5$//￿6287+￿(/(9$7,21 6&$/(￿ ￿￿￿￿￿￿ ￿￿￿￿￿￿%￿ (;,(;+*￿￿(;*(;)(;((;'(;&(;%(;$ 3$5$3(7￿% ￿￿￿￿￿ ￿￿ 3$5$3(7￿$ ￿￿￿￿￿ ￿￿ .(<￿3/$1 *5281'￿)/225 ￿￿ 29(5$//￿(/(9$7,21￿￿ ($67 1$￿6&$/(￿ ￿￿￿￿￿￿ ￿￿￿￿￿￿ 6+((7￿1$0( 29(5$//￿%8,/',1* (/(9$7,216 6+((7￿180%(5 $￿￿￿6287+￿:(67￿&251(5￿72:(5 6&$/(￿$￿ ￿￿￿￿￿￿    Page 25 ꢃꢍꢃꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢅ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢏ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢏ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢇ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢏ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢂ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢏ ꢃꢍꢄ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢏ ꢃꢍꢅ ꢃꢍꢇ ꢂꢍꢏ ꢂꢍꢅ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢊ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢏ ꢂꢍꢏ ꢂꢍꢅ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢊ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢅ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢊ ꢃꢍꢈ ꢂꢍꢏ ꢂꢍꢅ ꢂꢍꢊ ꢂꢍꢌ ꢃꢍꢌ ꢃꢍꢊ ꢃꢍꢆ ꢂꢍꢂ ꢂꢍꢊ ꢂꢍꢆ ꢌꢍꢂ ꢌꢍꢃ ꢂꢍꢄ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢄ ꢌꢍꢃ ꢌꢍꢂ ꢂꢍꢇ ꢂꢍꢅ ꢂꢍꢏ ꢂꢍꢂ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢆ ꢌꢍꢂ ꢌꢍꢃ ꢂꢍꢈ ꢂꢍꢏ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢏ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢅ ꢃꢍꢆ ꢂꢍꢅ ꢂꢍꢈ ꢂꢍꢆ ꢂꢍꢈ ꢃꢍꢂ ꢃꢍꢏ ꢃꢍꢄ ꢃꢍꢇ ꢂꢍꢏ ꢂꢍꢆ ꢌꢍꢌ ꢌꢍꢃ ꢂꢍꢅ ꢂꢍꢂ ꢃꢍꢆ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢅ ꢌꢍꢃ ꢌꢍꢌ ꢂꢍꢆ ꢂꢍꢏ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢏ ꢂꢍꢆ ꢌꢍꢌ ꢌꢍꢂ ꢂꢍꢄ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢈ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢃ ꢂꢍꢄ ꢌꢍꢃ ꢌꢍꢌ ꢌꢍꢌ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢂ ꢂꢍꢆ ꢌꢍꢃ ꢌꢍꢌ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢂ ꢂꢍꢇ ꢌꢍꢃ ꢌꢍꢃ ꢂꢍꢈ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢌ ꢌꢍꢃ ꢌꢍꢌ ꢂꢍꢇ ꢂꢍꢊ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢌ ꢌꢍꢃ ꢌꢍꢏ ꢂꢍꢇ ꢂꢍꢏ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢌ ꢌꢍꢃ ꢌꢍꢌ ꢂꢍꢇ ꢂꢍꢅ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢂ ꢂꢍꢇ ꢌꢍꢃ ꢌꢍꢂ ꢂꢍꢆ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢂ ꢂꢍꢆ ꢌꢍꢂ ꢌꢍꢏ ꢌꢍꢌ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢃ ꢂꢍꢈ ꢌꢍꢃ ꢌꢍꢌ ꢃꢍꢌ ꢃꢍꢅ ꢃꢍꢇ ꢂꢍꢈ ꢂꢍꢆ ꢂꢍꢆ ꢂꢍꢄ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢃ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢅ ꢂꢍꢌ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢂ ꢂꢍꢅ ꢂꢍꢈ ꢂꢍꢊ ꢂꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢂ ꢂꢍꢅ ꢂꢍꢆ ꢂꢍꢊ ꢃꢍꢇ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢃ ꢂꢍꢄ ꢂꢍꢆ ꢂꢍꢅ ꢂꢍꢂ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢃ ꢂꢍꢆ ꢂꢍꢆ ꢂꢍꢆ ꢂꢍꢅ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢂ ꢂꢍꢇ ꢌꢍꢂ ꢌꢍꢌ ꢌꢍꢂ ꢃꢍꢌ ꢃꢍꢈ ꢂꢍꢏ ꢌꢍꢂ ꢌꢍꢅ ꢌꢍꢄ ꢌꢍꢅ ꢃꢍꢏ ꢃꢍꢈ ꢂꢍꢊ ꢌꢍꢏ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢏ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢊ ꢌꢍꢅ ꢌꢍꢇ ꢌꢍꢄ ꢌꢍꢂ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢊ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢄ ꢌꢍꢂ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢅ ꢌꢍꢇ ꢌꢍꢆ ꢌꢍꢊ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢅ ꢌꢍꢇ ꢏꢍꢃ ꢌꢍꢈ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢇ ꢌꢍꢅ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢈ ꢌꢍꢌ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢄ ꢌꢍꢂ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢆ ꢌꢍꢊ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢈ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢇ ꢌꢍꢈ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢇ ꢌꢍꢄ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢈ ꢌꢍꢌ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢄ ꢌꢍꢂ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢈ ꢌꢍꢏ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢇ ꢌꢍꢄ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢇ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢈ ꢌꢍꢏ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢄ ꢌꢍꢂ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢅ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢈ ꢌꢍꢌ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢇ ꢌꢍꢄ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢅ ꢌꢍꢇ ꢌꢍꢇ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢄ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢆ ꢌꢍꢊ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢊ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢄ ꢌꢍꢂ ꢃꢍꢏ ꢃꢍꢆ ꢂꢍꢊ ꢌꢍꢅ ꢌꢍꢆ ꢌꢍꢄ ꢌꢍꢂ ꢃꢍꢌ ꢃꢍꢈ ꢂꢍꢊ ꢌꢍꢏ ꢌꢍꢄ ꢌꢍꢈ ꢌꢍꢊ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢌ ꢌꢍꢃ ꢌꢍꢊ ꢌꢍꢅ ꢌꢍꢊ ꢃꢍꢌ ꢃꢍꢄ ꢂꢍꢂ ꢌꢍꢃ ꢌꢍꢊ ꢌꢍꢆ ꢏꢍꢂ ꢂꢍꢆ ꢌꢍꢊ ꢃꢍꢌ ꢃꢍꢅ ꢂꢍꢃ ꢂꢍꢆ ꢌꢍꢏ ꢌꢍꢄ ꢌꢍꢈ ꢂꢍꢇ ꢌꢍꢅ ꢌꢍꢆ ꢌꢍꢆ ꢌꢍꢆ ꢏꢍꢃ ꢏꢍꢌ ꢏꢍꢂ ꢌꢍꢇ ꢌꢍꢇ ꢏꢍꢃ ꢏꢍꢌ ꢏꢍꢂ ꢌꢍꢇ ꢌꢍꢇ ꢏꢍꢂ ꢏꢍꢌ ꢏꢍꢃ ꢌꢍꢆ ꢌꢍꢇ ꢏꢍꢂ ꢏꢍꢌ ꢌꢍꢇ ꢌꢍꢈ ꢌꢍꢆ ꢌꢍꢆ ꢌꢍꢊ ꢂꢍꢆ ꢂꢍꢏ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢆ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢅ ꢃꢍꢇ ꢂꢍꢄ ꢌꢍꢌ ꢌꢍꢊ ꢌꢍꢊ ꢂꢍꢇ ꢌꢍꢏ ꢌꢍꢈ ꢌꢍꢇ ꢏꢍꢂ ꢏꢍꢂ ꢏꢍꢂ ꢏꢍꢂ ꢏꢍꢌ ꢏꢍꢌ ꢏꢍꢂ ꢏꢍꢌ ꢏꢍꢂ ꢏꢍꢌ ꢏꢍꢌ ꢏꢍꢂ ꢏꢍꢌ ꢏꢍꢂ ꢏꢍꢌ ꢏꢍꢌ ꢏꢍꢂ ꢏꢍꢂ ꢏꢍꢂ ꢏꢍꢂ ꢌꢍꢇ ꢌꢍꢈ ꢌꢍꢏ ꢂꢍꢆ ꢂꢍꢅ ꢂꢍꢌ ꢃꢍꢆ ꢃꢍꢊ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢊ ꢃꢍꢆ ꢂꢍꢏ ꢂꢍꢈ ꢂꢍꢆ ꢂꢍꢇ ꢂꢍꢈ ꢌꢍꢃ ꢌꢍꢏ ꢌꢍꢅ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢆ ꢌꢍꢆ ꢌꢍꢈ ꢌꢍꢆ ꢌꢍꢈ ꢌꢍꢆ ꢌꢍꢆ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢆ ꢌꢍꢆ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢅ ꢌꢍꢌ ꢌꢍꢃ ꢂꢍꢈ ꢂꢍꢏ ꢂꢍꢃ ꢃꢍꢈ ꢃꢍꢊ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢅ ꢃꢍꢅ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢃ ꢌꢍꢂꢌꢍꢂꢌꢍꢄꢌꢍꢈ WP-NEW WP-NEW WP-EX WP-EX WP-EX WP-EX WP-EX WP-EX WP-EX ꢌꢍꢄ ꢌꢍꢊ ꢌꢍꢏ ꢌꢍꢄ ꢌꢍꢇ WP-NEW WP-NEW WP-NEW WP-EX ꢌꢍꢆ ꢌꢍꢅ ꢌꢍꢊ ꢌꢍꢈ RENDERED PERSPECTIVE ꢌꢍꢇ WP-EX ꢌꢍꢈ ꢌꢍꢊ ꢌꢍꢅ ꢌꢍꢆ WꢌPꢍ-ꢇEX ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢅ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢅ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢃ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢌꢍꢈ ꢌꢍꢊ ꢌꢍꢅ ꢌꢍꢆ WP-EXꢌꢍꢇ ꢌꢍꢄ ꢌꢍꢏ ꢌꢍꢅ ꢌꢍꢄ WP-EX ꢌꢍꢏ ꢂꢍꢈ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢊ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢃ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢊ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢏ ꢃꢍꢃ ꢂꢍꢂ ꢂꢍꢊ ꢂꢍꢄ ꢂꢍꢅ ꢃꢍꢇ ꢃꢍꢄ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢂꢍꢈ ꢌꢍꢃ ꢂꢍꢇ ꢂꢍꢆ ꢂꢍꢌ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢅ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢌ ꢌꢍꢏ ꢌꢍꢅ ꢌꢍꢊ ꢌꢍꢂ ꢂꢍꢊ ꢃꢍꢇ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢌ WP-EꢌXꢍꢊꢌꢍꢌ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢈ ꢂꢍꢈ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢊ ꢃꢍꢏ ꢌꢍꢃ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢈ ꢂꢍꢌ ꢃꢍꢆ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢊ ꢂꢍꢅ ꢂꢍꢅ ꢂꢍꢅ ꢂꢍꢏ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢏ ꢌꢍꢌ ꢌꢍꢆ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢆ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢅ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢊ ꢌꢍꢄ ꢏꢍꢃ ꢏꢍꢃ ꢌꢍꢈ ꢌꢍꢃ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢄ ꢂꢍꢏ ꢂꢍPꢌL-1 ꢂꢍꢈ ꢂꢍꢅ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ WPꢌ-ꢍꢄEX ꢌꢍꢏ ꢌꢍꢆ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢇ ꢂꢍꢏ ꢃꢍꢇ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢅ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢊ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ ꢌꢍꢂ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢇ ꢂꢍꢆ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢌ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢅ ꢌꢍꢌ ꢌꢍꢈ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢆ ꢂꢍꢌ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢅ ꢌꢍꢅ ꢌꢍꢇ ꢏꢍꢃ ꢌꢍꢈ ꢂꢍꢇ ꢂꢍꢌ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢅ WꢌꢍPꢄ-EX ꢏꢍꢃ ꢏꢍꢃ ꢌꢍꢈ ꢂꢍꢇ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ ꢌꢍꢏ ꢌꢍꢆ ꢏꢍꢃ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢈ ꢌꢍꢂ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢈ ꢂꢍꢂ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢈ ꢌꢍꢂ ꢌꢍꢈ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢈ ꢂꢍꢂ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢊ ꢌꢍꢇ ꢏꢍꢃ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢂ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢊ ꢂꢍꢃ ꢃꢍꢇ ꢌꢍWꢄ P-EX ꢌꢍꢊꢌꢍꢂ ꢌꢍꢈ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢄ ꢂꢍꢂ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢏ ꢂꢍꢃ ꢃꢍꢇ ꢌꢍꢂ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢄ ꢂꢍꢂ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢏ ꢂꢍꢊ ꢂꢍꢅ ꢂꢍꢅ ꢂꢍꢊ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢊ ꢌꢍꢆ ꢏꢍꢃ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢏ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢄ WP-EXꢌꢍꢅꢌꢍꢂ ꢌꢍꢈ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢈ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢃ ꢌꢍꢄ ꢏꢍꢃ ꢌꢍꢆ ꢂꢍꢈ ꢂꢍꢂ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢏ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢏ ꢌꢍꢆ ꢌꢍꢇ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢅ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢏ ꢂꢍꢂ ꢃꢍꢇ ꢌꢍꢄ ꢌꢍꢇ ꢏꢍꢃ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢆ ꢂꢍꢆ ꢂꢍꢈ ꢂꢍꢊ ꢂꢍꢂ ꢃꢍꢇ WP-EꢌXꢍꢅꢌꢍꢌ ꢌꢍꢈ ꢌꢍꢇ ꢌꢍꢈ ꢂꢍꢈ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢅ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢏ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢃ ꢌꢍꢄ ꢌꢍꢇ ꢌꢍꢈ ꢂꢍꢄ ꢂꢍꢂ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢏ ꢂꢍꢅ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢊ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢆ ꢌꢍꢌ ꢌꢍꢄ ꢌꢍꢆ ꢌꢍꢄ ꢂꢍꢄ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢏ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢈ ꢌꢍꢊ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢏ ꢂꢍꢄ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ WPꢌ-ꢍꢏEX ꢂꢍꢈ ꢂꢍꢇ ꢂꢍꢇ ꢂꢍꢇ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢅ ꢂꢍꢂ ꢂꢍꢊ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢅ ꢌꢍꢈ ꢌꢍꢈ ꢌꢍꢊ ꢂꢍꢈ ꢂꢍꢃ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢇ ꢃꢍꢇ ꢃꢍꢇ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢏ ꢏꢍꢃ ꢏꢍꢃ ꢌꢍꢆ ꢌꢍꢃ ꢂꢍꢏ ꢃꢍꢇ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢅ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ ꢏꢍꢃ ꢏꢍꢃ ꢌꢍꢄ ꢂꢍꢆ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢊ ꢌꢍꢆ ꢏꢍꢃ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢆ ꢂꢍꢆ ꢂꢍꢈ ꢂꢍꢊ ꢂꢍꢂ ꢃꢍꢇ ꢏꢍꢃ ꢏꢍꢃ ꢌꢍꢄ ꢂꢍꢇ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢇ ꢌꢍꢇ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢏ ꢂꢍꢊ ꢂꢍꢊ ꢂꢍꢏ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢌꢍꢇ ꢌꢍꢇ ꢌꢍꢈ ꢂꢍꢆ ꢂꢍꢃ ꢃꢍꢄ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢆ ꢌꢍꢊ ꢌꢍꢏ ꢌꢍꢂ ꢂꢍꢊ ꢃꢍꢇ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢇ ꢂꢍꢃ ꢂꢍꢂ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢌ ꢂꢍꢂ ꢂꢍꢃ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢄ ꢂꢍꢏ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢂ ꢂꢍꢏ ꢂꢍꢅ ꢂꢍꢅ ꢂꢍꢅ ꢂꢍꢏ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ ꢃꢍꢂ ꢃꢍꢌ ꢃꢍꢏ ꢃꢍꢊ ꢃꢍꢄ ꢃꢍꢆ ꢃꢍꢇ ꢂꢍꢌ ꢂꢍꢅ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢄ ꢂꢍꢊ ꢂꢍꢂ ꢃꢍꢇ ꢃꢍꢈ ꢃꢍꢅ ꢃꢍꢊ ꢃꢍꢆ ꢃꢍꢈ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢌ ꢂꢍꢅ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ ꢃꢍꢄ ꢃꢍꢄ ꢃꢍꢈ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢄ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢅ ꢂꢍꢌ ꢂꢍꢃ ꢃꢍꢆ ꢃꢍꢄ ꢃꢍꢊ ꢃꢍꢏ ꢃꢍꢅ ꢃꢍꢄ ꢃꢍꢆ ꢂꢍꢃ ꢂꢍꢏ ꢂꢍꢄ ꢂꢍꢈꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢏ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ PL-ꢍ1ꢈ ꢂ ꢂꢍꢄ ꢂꢍꢅ ꢂꢍꢌ ꢃꢍꢇ ꢃꢍꢆ ꢃꢍꢅ ꢃꢍꢊ PL-1 PL-1 ꢃꢍꢌ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢃꢍꢂ ꢂꢍꢆ ꢂꢍꢈ ꢂꢍꢊ ꢂꢍꢃ ꢃꢍꢇ ꢂꢍꢈ ꢂꢍꢈ ꢂꢍꢊ ꢂꢍꢂ ꢃꢍꢇꢃꢍꢃ Designer Date 02/06/2024 Scale Not to Scale Drawing No. Plan View Scale 1" 20ft Summary -=    Page 26 DESIGN REVIEW COMMENTS October 1, 2024 6:00 p.m. Tabe van der Zwaag, Associate Planner ENVIRONMENTAL ASSESSMENT, DESIGN REVIEW AND CONDITIONAL USE PERMIT – GORRE ARCHITECHTS FOR CAL BOX - A request for site plan and architectural review of 45,993 square foot addition to an existing 98,406 square foot industrial building and a Conditional Use Permit to operate a manufacturing use over 50,000 square feet located on approximately 7.7 acres of land within Mixed Employment 2 (ME2) Zone, located on the east side of Toronto Avenue where it terminates into the BNSF/Metrolink right of way; APN: 0209-401-05. (Design Review DRC2023-00379 and Conditional Use Permit DRC2024-00288). The project qualifies as a Class 32 exemption under State CEQA Guidelines Section 15332 – Infill Development Projects. Site Characteristics: The project site is located at the terminus of Toronto Avenue and is developed with a 98,406 square foot industrial building. The parcel is approximately 532 feet from east to west and 613 feet from north to south, with an area of approximately 336,283 square feet (7.7 acres). The right-of-way improvements (including landscaping, and utility undergrounding along Toronto Avenue have been installed and will remain as part of this project. The existing Land Use, General Plan and Zoning designations for the project site and adjacent properties are as follows: Project Overview: The applicant proposes constructing a 45,993 square foot addition on the west side of the existing 98,406 square foot industrial building that is used manufacturing purposes. The addition will be used to store raw material and finished goods related to the main manufacturing use. While the proposed use is permitted with a Conditional Use Permit pursuant to Development Code Section 17.136.010 (Allowed Land Uses), the existing building on the site is non-conforming in terms of street side setbacks. Development Code Section 17.62.030-B (Alteration and Additions to Nonconforming Uses and Structures) states that “(n)o nonconforming structure shall be altered or reconstructed that results in an increase of the discrepancy between existing conditions and the standards for front yard, side yards, rear yard or height of structures, distances between structures, and parking facilities…”. The proposed building addition will reduce the discrepancy between current conditions and the required setbacks as the addition will bring the overall building closer to the street. The proposed building will be of concrete tilt-up construction and designed to match the existing building including the use of form lines and high windows. Two-story glazing has been added to the southwest corner of the addition to create visual interest, along with new landscaping along the west and south elevations and decorative paving at the main vehicle entrance. The Land Use General Plan Zoning Site Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) North BNSF/Metrolink Right of Way - Industrial Employment (IE) South Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) East Vacant Land City Center Center 2 (CE2) West Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) Exhibit C    Page 27 DRC COMMENTS DRC2023-00379 – GORRE ARCHITECHTS FOR CAL BOX October 1, 2024 Page 2 landscaping in the existing parking lot area has been enhanced to meet current landscape requirements. The existing and new loading areas, dock doors and trailer parking stalls are located on the north and south elevations of the building and screened from public view by an existing wall and by the building. The project was designed to bring the site into closer conformance with development standards of the Mixed Employment 2 (Zone) including building and parking setbacks, number of parking spaces, and floor area ratio as shown on the following tables: Required Provided Compliant? Building Setback (Street) 15 Feet Maximum 78 Feet Yes Building Setback (Side) N/A 40 and 50 Feet Yes Building Setback (Rear) N/A 135 Feet Yes Parking Setback 10 Foot Minimum 81 Feet Yes Landscape Coverage N/A 10.8 Percent Yes Floor Area Ratio .4 – 2.0 Percent 43 Percent Yes Building Height 4 Stories 1 Story Yes Parking: Parking Ratio Required Parking Provided Parking Office Parking (5,585 SF) 1:250 SF 22 Spaces 22 Spaces Manufacturing (11,779 SF) 2:1,000 SF 24 Space 24 Space Warehouse Parking (180,186 SF) 1:1,000 for 1st 20,000 SF 1:2,000 for 2nd 20,000 SF 1:4,000 for the Remaining SF 48 Spaces 48 Spaces Total Vehicle Parking 94 Spaces 103 Spaces Trailer Parking (11 Dock High Doors) 1 per Dock High Door 11 Spaces 11 Spaces Staff Recommendation: Staff supports the proposed addition to the existing industrial building. The building is designed to be architecturally compatible with the existing building and onsite improvements. The building addition will reduce the current non-conforming street setback by bringing the overall building closer to the public street. Staff requests that the Design Review Committee consider the design (building architecture, site planning, etc.) of the proposed project and recommend the selected action below: ☒Recommend Approval of the design of the project as proposed by the applicant. ☐Recommend Approval with Modifications to the design of the project by incorporating revisions requested by the Committee. Follow-up review by the Committee is not required. The revisions shall be verified by staff prior to review and action by the Planning Director / Planning Commission. ☐Recommend Conditional Approval of the design of the project by incorporating revisions requested by the Committee. Follow-up review by the Committee is not required. The revisions shall be Conditions of Approval and verified by staff during plan check after review and action by the Planning Director / Planning Commission.    Page 28 DRC COMMENTS DRC2023-00379 – GORRE ARCHITECHTS FOR CAL BOX October 1, 2024 Page 3 ☐Recommend Denial of the design of the project as proposed by the applicant. Design Review Committee Action: Staff Planner: Tabe van der Zwaag, Associate Planner Members Present: Staff Coordinator: Sean McPherson, Principal Planner Exhibit A – Project Plans    Page 29 Design Review Committee Meeting Agenda October 1, 2024 FINAL MINUTES Rancho Cucamonga, CA 91730 New Time: 6:00 p.m. A. Call to Order The meeting of the Design Review Committee held on October 1, 2024. The meeting was called to order by Sean McPherson, Staff Coordinator, at 6:00 p.m. Design Review Committee members present: Vice Chairman Boling and Commissioner Diaz Correction to the members present; remove Commissioner Diaz and replace with Commissioner Daniels. Staff Present: Tabe van der Zwaag, Associate Planner B. Public Communications Staff Coordinator opened the public communication and after noting there were no public comments, closed public communications. C. Consent Calendar C1. Consideration to adopt Meeting Minutes of September 17, 2024. Item C1. Motion carried 2-0 vote. D. Project Review Items D1. ENVIRONMENTAL ASSESSMENT, TENTATIVE MAP, DESIGN REVIEW & VARIANCE – GRAND PACIFIC COMMUNITIES – A request to subdivide approximately 1.7 acres of land into 8 numbered and 4 lettered lots including site plan and design review of 8 duplexes (16 units total), and a variance to reduce the required streetscape setback for a site located between 19th and Hamilton Streets east of Hermosa Avenue in the Medium Residential (M) Zone; APN: 1076-121-03 (Tentative Tract Map SUBTT20662, Design Review DRC2023- 00363, and Variance DRC2024-00300). The project qualifies as a Class 32 exemption under State CEQA Guidelines Section 15332 – Infill Development Projects. Staff presented the item. Committee members asked a number of questions regarding WQMP facilities, wall height, street width, and requirements for completing sidewalks. Additional questions from committee members included landscaping, specifically that the applicant consider a tree type that does not drop pods, the placement of mailboxes, the placement of solar and location of trash cans. Committee Members complimented the design. Committee Member Boling inquired about the need for crosswalks and crossing guards, considering the new proposed street included within the project design would terminate right in front of an elementary school. Committee Members recommended that the applicant contact the school district and City engineering department for requirements on crosswalks and crossing guards. Committee members voted to move the item forward to the full Planning Commission with the motion that the applicant consider flashing beacons in any potential crosswalk and coordinate with the school district on the need for crossing guards and any other requirements the school district may desire. The motion also included that the applicant consider revising the landscape    Page 30 plan as well as incorporate a dog relief station within the WQMP area. The Committee took the following action: Recommend approval to PC. 2-0 Vote. D2. ENVIRONMENTAL ASSESSMENT, DESIGN REVIEW AND CONDITIONAL USE PERMIT – GORRE ARCHITECHTS FOR CAL BOX - A request for site plan and architectural review of 45,993 square foot addition to an existing 98,406 square foot industrial building and a Conditional Use Permit to operate a manufacturing use over 50,000 square feet located on approximately 7.7 acres of land within Mixed Employment 2 (ME2) Zone, located on the east side of Toronto Avenue where it terminates into the BNSF/Metrolink right of way; APN: 0209- 401-05. (Design Review DRC2023-00379 and Conditional Use Permit DRC2024-00288). The project qualifies as a Class 32 exemption under State CEQA Guidelines Section 15332 – Infill Development Projects. Staff presented the item. Committee members asked general questions related to nonconforming setbacks and the project’s compliance with other standards. Committee members asked the applicant questions about the history of their business in Rancho Cucamonga and about business operations related to the proposed addition. Committee members noted that the plan set did not include colored renderings which would have been helpful in their review. Particularly since this is an addition to an existing building, colored renderings would be helpful to distinguish the existing structure from the new addition. Staff responded that these items will be addressed prior to the item going to the Planning Commission. The Committee took the following action: Recommend approval to PC. 2-0 Vote. E. Adjournment Principal Planner Sean McPherson adjourned the meeting at 6:53 p.m. Respectfully submitted, ___________________________ Elizabeth Thornhill, Executive Assistant    Page 31 EXHIBIT D Due to file size, this attachment can be accessed through the following link: Section 15332 Categorical Exemption Memorandum    Page 32 RESOLUTION NO. 25-012 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING DESIGN REVIEW DRC2023-00379, FOR SITE PLAN AND ARCHITECTURAL REVIEW OF A 45,993 SQUARE FOOT ADDITION TO AN EXISTING 98,406 SQUARE FOOT INDUSTRIAL BUILDING LOCATED ON APPROXIMATELY 7.7 ACRES OF LAND WITHIN MIXED EMPLOYMENT 2 (ME2) ZONE, LOCATED AT 8949 TORONTO AVENUE; AND MAKING FINDINGS IN SUPPORT THEREOF – APN: 0209-401-05. A.Recitals. 1.Goree Architects for Cal Box filed an application for the issuance of Design Review DRC2023-00379, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Design Review request is referred to as "the application." 2.On the 23rd day of April 2025, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on said application and concluded said hearing on that date. 3.All legal prerequisites prior to the adoption of this Resolution have occurred. B.Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1.This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2.Based upon the substantial evidence presented to this Commission during the above-referenced meeting on April 23, 2025, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a.The application applies to a project site located 8949 Toronto Avenue (APN: 0209- 401-05); and b.The existing Land Use, General Plan, and Zoning designations for the project site and adjacent properties are as follows: Exhibit E   Page 33 PLANNING COMMISSION RESOLUTION NO. 2025-012 DESIGN REVIEW DRC2023-00379 – GOREE ARCHITECHTS FOR CAL BOX April 23, 2025 Page 2 c. Approval is for the design review and site layout of a 45,993 square foot addition to an existing 98,406 square foot industrial building; and d. This application is in conjunction with Conditional Use Permit DRC2024-00288 to operate a Light Manufacturing Large land use in the resulting 144,399 square foot building. 3. Based upon the substantial evidence presented to this Commission during the above- referenced meeting and upon the specific findings of facts set forth in Paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The proposed project is consistent with the General Plan, which designates the site as 21st Century Employment District. This designation allows for the expansion of existing industrial uses, provided they maintain clean industrial operations. The project includes the construction of a 45,993-square-foot addition to an existing 98,406-square-foot industrial building used for manufacturing purposes, aligning with the intent of the General Plan; and b. The proposed use is in accord with the objective of the Development Code and the purposes of the district in which the site is located as the project site is within the Mixed Employment 2 (ME2) Zone which permits Light Manufacturing Large land uses subject to the approval of a Conditional Use Permit; and c. The proposed use is in compliance with each of the applicable provisions of the Development Code. The Development Code permits the expansion of existing non-conforming buildings that do not result in an increase of the discrepancy between existing conditions and the standards for “front yard, side yards, rear yard or height of structures, distances between structures, and parking facilities…”. The proposed addition will reduce the current non-conforming front setback in conformance with the Development Code; and d. The proposed use, together with the conditions applicable thereto, will not be detrimental to the public health, safety, or welfare, or materially injurious to properties or improvements in the vicinity. A CEQA exemption was prepared for the project which determined that the propose building addition would not have a significant impact on the environment. 4. Planning staff has determined that the project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) and the City’s CEQA Guidelines. The project qualifies as a Class 32 exemption under State CEQA Guidelines Section 15332 – Infill Development Projects, as the project is for the construction of a 45,993-square-foot addition to an existing 98,406-square-foot industrial building. The Section 15332 CEQA exemption covers infill Land Use General Plan Zoning Site Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) North BNSF/Metrolink Right of Way - - South Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) East Vacant Land City Center Center 2 (CE2) West Industrial Building 21st Century Employment District Mixed Employment 2 (ME2)    Page 34 PLANNING COMMISSION RESOLUTION NO. 2025-012 DESIGN REVIEW DRC2023-00379 – GOREE ARCHITECHTS FOR CAL BOX April 23, 2025 Page 3 developments on sites less than 5 acres in area that will not have a significant impact relating to traffic, noise, air quality, or water. A Section 15332 CEQA exemption was prepared by UES (April 2025), an environmental consultant hired by the City (Exhibit D – CEQA Section 15332 Infill Exemption), to demonstrate compliance with the Section 15332 exemption. Staff evaluated the CEQA exemption prepared by UES and concluded that the impacted area is less than 5 acres in area and will not have a significant impact on the environment relating to biological resources, traffic, noise, air quality, or water. The Planning Commission has reviewed the Planning Department’s determination of exemption, and based on its own independent judgment, concurs with staff's determination of exemption. 5. Based upon the findings and conclusions set forth in Paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth in the Standard Conditions, attached hereto and incorporated herein by this reference. 6. The Secretary to this Commission shall certify the adoption of this Resolution. APPROVED AND ADOPTED THIS 23RD DAY OF April 2025. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: Tony Morales, Chairman ATTEST: Jennifer Nakamura, Secretary I, Jennifer Nakamura, Secretary of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 23rd day of April 2025, by the following vote-to-wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS:    Page 35 RESOLUTION NO. 25-013 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT DRC2024-00288, TO OPERATE A MANUFACTURING USE OVER 50,000 SQUARE FEET ON APPROXIMATELY 7.7 ACRES OF LAND IN THE MIXED EMPLOYMENT 2 (ME2) ZONE, LOCATED AT 8949 TORONTO AVENUE; AND MAKING FINDINGS IN SUPPORT THEREOF – APN: 0209-401-05. A. Recitals. 1. Goree Architects for Cal Box filed an application for the issuance of Conditional Use Permit DRC2024-00288, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Conditional Use Permit request is referred to as "the application." 2. On the 23rd day of April 2025, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on said application and concluded said hearing on that date. 3. All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2. Based upon the substantial evidence presented to this Commission during the above-referenced meeting on April 23, 2025, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a. The application applies to a project site located at 8949 Toronto Avenue (APN: 0209-401-05); and b. The existing Land Use, General Plan, and Zoning designations for the project site and adjacent properties are as follows: Land Use General Plan Zoning Site Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) North BNSF/Metrolink Right of Way - - South Industrial Building 21st Century Employment District Mixed Employment 2 (ME2) East Vacant Land City Center Center 2 (CE2) West Industrial Building 21st Century Employment District Mixed Employment 2 (ME2)    Page 36 PLANNING COMMISSION RESOLUTION NO. 2025-013 CONDITIONAL USE PERMIT DRC2024-00288 – GOREE ARCHITECHTS FOR CAL BOX April 23, 2025 Page 2 c. Approval is for the operation of a Light Manufacturing Large land use within a 144,399 square foot building; and d. The subject Conditional Use Permit is related to Development Review DRC2023- 00379 to expand an existing 98,406 square foot building by 45,993 square feet (total area 144,399). 3. Based upon the substantial evidence presented to this Commission during the above- referenced meeting and upon the specific findings of facts set forth in Paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The use is consistent with the general plan designation. The 21st Century Employment District permits existing industrial uses to remain. The site is developed with an existing industrial building, parking, and landscaping. The related expansion of the existing industrial building (Design Review DRC2023-00379) is not expected to increase the number of employees or vehicle trips to the project site as it will bring activities that currently take place outdoors within the expanded building footprint; and b. The proposed use is consistent with the purposes of the Development Code and the purposes of the applicable zone as well as any applicable specific plans or city regulations/standards. Per Development Code Table 17.136.020-1 (Allowed Land Uses in Form- Based Zones), manufacturing uses over 50,000 square feet are classified as Light Manufacturing Large and require the approval of a Conditional Use Permit (CUP) in the Mixed Employment 2 (ME2) Zone. The existing manufacturing use has been in operation in the current location prior to the CUP requirement. With the proposed expansion, the existing manufacturing use must obtain a CUP to comply with this requirement; and c. The site is physically suitable for the type, density, and intensity of the use being proposed, including access, utilities, and the absence of physical constraints that would make conduct of the use undesirable. The project’s scale and operation align with the intensity of neighboring land uses. The proposed conditions of approval will ensure compliance with performance criteria, safety standards, maintenance expectations, and all related municipal codes to mitigate any potential adverse impacts associated with the manufacturing process; and d. The design, location, size, and operating characteristics of the proposed use would be compatible with the existing and other permitted uses in the vicinity, including transportation and service facilities. The manufacturing use on the site will take place entirely indoors, and the intensity of the use is not expected to exceed that of the current use on the site; and e. Granting the permit would not constitute a nuisance or be injurious or detrimental to the public interest, health, safety, convenience, or welfare, or materially injurious to persons, property, or improvements in the vicinity and zone in which the property is located. The scale and operation of the use are of similar intensity to the surrounding uses. The use has been conditioned to meet performance criteria, safety standards, maintenance standards, and all other Municipal Code standards to mitigate any potential impact related to the proposed manufacturing use; and f. The proposed use will not pose an undue burden on city services, including police, fire, streets, and other public utilities, such that the city is unable to maintain its current level of service due to the use. The expansion of the existing operation is not expected to hinder the city’s ability to maintain its current level of service; and    Page 37 PLANNING COMMISSION RESOLUTION NO. 2025-013 CONDITIONAL USE PERMIT DRC2024-00288 – GOREE ARCHITECHTS FOR CAL BOX April 23, 2025 Page 3 g. The proposed project has been reviewed in compliance with the California Environmental Quality Act (CEQA). The project qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 – Existing Facilities, as outlined in Section 4 below. 4. Planning staff has determined that the project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) and the City’s CEQA Guidelines. The project also qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 – Existing Facilities, which covers the permitting of existing structures . The Planning Commission has reviewed the Planning Department’s determination of exemption, and based on its own independent judgment, concurs with staff's determination of exemption. 5. Based upon the findings and conclusions set forth in Paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth in the Standard Conditions, attached hereto and incorporated herein by this reference. 6. The Secretary to this Commission shall certify the adoption of this Resolution. APPROVED AND ADOPTED THIS 23RD DAY OF APRIL 2025. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: Tony Morales, Chairman ATTEST: Jennifer Nakamura, Secretary I, Jennifer Nakamura, Secretary of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 23rd day of April 2025, by the following vote-to-wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS:    Page 38 Conditions of Approval Community Development Department Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval The applicant shall sign the Statement of Agreement and Acceptance of Conditions of Approval provided by the Planning Department. The signed Statement of Agreement and Acceptance of Conditions of Approval shall be returned to the Planning Department prior to the submittal of grading/construction plans for plan check, request for a business license, and/or commencement of the approved activity. 1. The applicant shall indemnify, protect, defend, and hold harmless, the City, and/or any of its officials , officers, employees, agents, departments, agencies, those City agents serving as independent contractors in the role of City officials and instrumentalities thereof (collectively “Indemnitees”), from any and all claims, demands, lawsuits, writs of mandamus, and other actions and proceedings (whether legal, equitable, declaratory, administrative or adjudicatory in nature ), and alternative dispute resolutions procedures (including, but not limited to, arbitrations, mediations, and other such procedures ) (collectively “Actions”), brought against the City, and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof, that challenge, attack, or seek to modify, set aside, void, or annul, the action of, or any permit or approval issued by, the City and /or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof (including actions approved by the voters of the City ), for or concerning the project, whether such actions are brought under the California Environmental Quality Act (CEQA), State Planning and Zoning Law, the Subdivisions Map Act, Code of Civil Procedure Section 1085 or 1094.5, or any other state, federal, or local statute, law, ordinance, rule, regulation, or any decision of a competent jurisdiction. This indemnification provision expressly includes losses, judgments, costs, and expenses (including, without limitation, attorneys’ fees or court costs) in any manner arising out of or incident to this approval, the Planning Director’s actions, the Planning Commission’s actions, and/or the City Council’s actions , related entitlements, or the City’s environmental review thereof. The Applicant shall pay and satisfy any judgment, award or decree that may be rendered against City or the other Indemnitees in any such suit , action, or other legal proceeding. It is expressly agreed that the City shall have the right to approve , which approval will not be unreasonably withheld, the legal counsel providing the City’s defense, and that the applicant shall reimburse City for any costs and expenses directly and necessarily incurred by the City in the course of the defense. City shall promptly notify the applicant of any Action brought and City shall cooperate with applicant in the defense of the Action. In the event such a legal action is filed challenging the City’s determinations herein or the issuance of the approval, the City shall estimate its expenses for the litigation. The Applicant shall deposit said amount with the City or, at the discretion of the City, enter into an agreement with the City to pay such expenses as they become due. 2. www.CityofRC.us Printed: 4/10/2025    Page 39 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval The applicant shall be required to pay California Department of Fish and Wildlife Notice of Exemption fee in the amount of $50.00. All checks are to be made payable to the Clerk of the Board Supervisors and submitted to the Planning Commission Secretary prior to public hearing or within 5 days of the date of project approval. 3. Any approval shall expire if Building Permits are not issued or approved use has not commenced within 2 years from the date of approval or a time extension has been granted. 4. Any modification or intensification of the approved use, including revisions in the operations of the business including changes to the operating days /hours; change in the location on -site or within the building of the use /activity that is approved by this Conditional Use Permit; improvements including new building construction; and/or other modifications /intensification beyond what is specifically approved by this Conditional Use Permit, shall require the review and approval by the Planning Director prior to submittal of documents for plan check /occupancy, construction, commencement of the activity, and/or issuance of a business license. The Planning Director may determine that modifications or intensifications of use require the submittal of an application to modify this Conditional Use Permit for review by the City. 5. This project is subject to public art requirement outlined in Chapter 17.124 of the Development Code . Prior to the issuance of building permits (for grading or construction ), the applicant shall inform the Planning Department of their choice to install public art, donate art or select the in -lieu option as outlined in 17.124.020.D. If the project developer chooses to pay the in -lieu fee, the in-lieu art fee will be invoiced on the building permit by the City and shall be paid by the applicant prior to building permit issuance. If the project developer chooses to install art, they shall submit, during the plan check process, an application for the art work that will be installed on the project site that contains information applicable to the art work in addition to any other information as may be required by the City to adequately evaluate the proposed the art work in accordance with the requirements of Chapter 17.124. If the project developer chooses to donate art, applications for art work donated to the City shall be subject to review by the Public Art Committee which shall make a recommendation whether the proposed donation is consistent with Chapter 17.124 and final acceptance by the City Council. No final approval, such as a final inspection or the a issuance of a Certificate of Occupancy, for any development project (or if a multi-phased project, the final phase of a development project) that is subject to this requirement shall occur unless the public art requirement has been fulfilled to the satisfaction of the Planning Department. 6. Approval of this request shall not waive compliance with all sections of the Development Code and all other applicable City Ordinances. 7. Downspouts shall not be visible from the exterior of any elevations of the buildings. All downspouts shall be routed through the interior of the building walls. 8. www.CityofRC.us Page 2 of 11Printed: 4/10/2025    Page 40 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval All ground-mounted utility appurtenances such as transformers, AC condensers, etc., shall be located out of public view and adequately screened through the use of a combination of concrete or masonry walls, berming, and/or landscaping to the satisfaction of the Planning Director. For single -family residential developments, transformers shall be placed in underground vaults. 9. All parking spaces shall be 9 feet wide by 17 feet long with a required 1-foot overhang (e.g., over a curb stop). 10. All parking spaces shall be double striped per City standards and all driveway aisles, entrances, and exits shall be striped per City standards. 11. For commercial and industrial projects, paint roll -up doors and service doors to match main building colors. 12. All roof appurtenances, including air conditioners and other roof mounted equipment and /or projections shall be screened from all sides and the sound shall be buffered from adjacent properties and streets as required by the Planning Department. Such screening shall be architecturally integrated with the building design and constructed to the satisfaction of the Planning Director. Any roof -mounted mechanical equipment and /or ductwork, that projects vertically more than 18 inches above the roof or roof parapet, shall be screened by an architecturally designed enclosure which exhibits a permanent nature with the building design and is detailed consistent with the building. Any roof -mounted mechanical equipment and /or ductwork, that projects vertically less than 18 inches above the roof or roof parapet shall be painted consistent with the color scheme of the building. Details shall be included in building plans. 13. Engineering Services Department Please be advised of the following Special Conditions Development Impact Fees: Development Impact Fees Due Prior to Building Permit Issuance (Subject to Change / Periodic Increases - Refer to current fee schedule to determine current amounts) 1. www.CityofRC.us Page 3 of 11Printed: 4/10/2025    Page 41 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Please be advised of the following Special Conditions Except as otherwise provided in this condition, the applicant shall pay an in -lieu fee to the City’s Active Transportation Fund in an amount determined by the City Engineer. This fee shall be used for the design and construction of the multipurpose trail located along the northerly side of the parcel limits (approximately 533 feet). The in-lieu fee shall include the construction and /or installation of a paved Class 1 Bikeway, sidewalk, signage, striping, landscape, and lighting, and design costs. The in -lieu fee improvement requirements may change if the payment of the in -lieu fee satisfies the project’s obligation for active transportation improvements and must be completed prior Certificate of Occupancy. The City is undergoing an amendment change to the General Plan that may alter or eliminate the required on-site multipurpose trail required as of the date of this approval. If the General Plan amendment alters the multipurpose trail, the in -lieu fee for the required improvements listed above may change. If the amendment to the General Plan is approved with the elimination of the on -site multipurpose trial prior to Certificate of Occupancy, this condition of approval will no longer be required or imposed by the City on the project. 2. Standard Conditions of Approval ** CD Information Required Prior to Sign-Off for Building Permit Prior to the issuance of building permits, if valuation is greater or equal to $100,000, a Diversion Deposit and a related administrative fee shall be paid for the Construction and Demolition Diversion Program. The deposit is fully refundable if at least 65% of all wastes generated during construction and demolition are diverted from landfills, and appropriate documentation is provided to the City. Applicant must identify if they are self -hauling or utilizing Burrtec prior to issuance of a building permit. Proof of diversion must be submitted to the Environmental Engineering Division within 60 days following the completion of the construction and / or demolition project. Contact Marissa Ostos, Environmental Engineering, at (909) 774-4062 for more information. Instructions and forms are available at the City 's website, www.cityofrc.us, under City Hall / Engineering / Environmental Programs / Construction & Demolition Diversion Program. 3. The developer shall be responsible for the relocation of existing utilities as necessary.4. Fire Prevention / New Construction Unit Standard Conditions of Approval Access doors are required to be identified in accordance with Fire District Standard 5-5. The Standard has been uploaded to the Documents section. 1. Plans for the private, onsite fire underground water infrastructure are required to be submitted separately and issued a separate permit. Submit all plans to the Building Department for routing to the Fire District. 2. www.CityofRC.us Page 4 of 11Printed: 4/10/2025    Page 42 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Fire Prevention / New Construction Unit Standard Conditions of Approval Plans for the racks used for high piled combustible storage are required to be submitted separately and issued a separate permit. Submit all plans to the Building Department for routing to the Fire District. 3. Any changes or modifications to the fire sprinkler system, fire alarm system, exhaust hood fire suppression system, or the commercial cooking appliances require the approval of the Fire District . Plans for modifications are required to be deferred submittals with the work completed under separate permits. 4. Plans for high piled combustible storage are required to be submitted separately and issued a separate permit. Submit all plans to the Building Department for routing to the Fire District. 5. Emergency responder communication coverage in accordance with Fire District Standard 5-12 is required for the building (s) included in this project. A radio signal strength test of the public safety radio communication system conducted in accordance with the requirements of the 2022 California Fire Code is required to be submitted. Where existing radio signal strength does not meet the requirements of the Fire Code, a separate submittal for an emergency responder communication coverage system is required. 6. The warehouse portion of this building may be allowed to utilize forklift and powered industrial truck mounted fire extinguishers to meet the Fire Code requirement for fire extinguishers. Please consult with the fire code official. 7. Fire extinguishers are required in accordance with Section 906 of the California Fire Code. Consult with the Fire Inspector for the correct type, size, and exact installation locations. 8. Fire flow information for this project is obtained from the Cucamonga Valley Water District (CVWD). CVWD can be reached at 909-944-6000 or custserv@cvwdwater.com. 9. Fire flow is required to be in accordance with Appendix B of the California Fire Code. The Fire District has adopted the appendix without local amendments except that the minimum fire flow for commercial buildings shall not be less than 1500 gpm. Proof of the availability of the required fire flow must be provided to the Fire District in the form of a letter or written report dated within the past 12 months. 10. The most current versions of the Fire District's Standards can be found at: https://www.dropbox.com/sh/86zjfacfxqh8oeo/AABYEQ81w5vL7WZ7e1zBiu25a?dl=0 11. Building and Safety Services Department Please be advised of the following Special Conditions When the Entitlement Review is approved submit complete construction drawings to Building and Safety for plan review in accordance with the current edition of the California Building and Fire Codes including all local ordinances and standards. 1. Grading Section Standard Conditions of Approval www.CityofRC.us Page 5 of 11Printed: 4/10/2025    Page 43 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval Grading of the subject property shall be in accordance with current adopted California Building Code and/or the California Residential Code, City Grading Standards, and accepted grading practices. The Grading and Drainage Plan (s) shall be in substantial conformance with the approved conceptual Grading and Drainage Plan. 1. A soils report shall be prepared by a qualified Engineer licensed by the State of California to perform such work. Two copies will be provided at grading and drainage plan submittal for review. Plans shall implement design recommendations per said report. 2. The final Grading and Drainage Plan, appropriate certifications and compaction reports shall be completed, submitted, and approved by the Building and Safety Official prior to the issuance of building permits. 3. A separate Grading and Drainage Plan check submittal is required for all new construction projects and for existing buildings where improvements being proposed will generate 50 cubic yards or more of combined cut and fill. The Grading and Drainage Plan shall be prepared, stamped, and wet signed by a California licensed Civil Engineer prior to the issuance of a grading or building permit. The Grading and Drainage Plan shall be submitted to the Engineering Services Department for review and approval. 4. The applicant shall comply with the City of Rancho Cucamonga Dust Control Measures and place a dust control sign on the project site prior to the issuance of a grading permit. All dust control sign (s) shall be located outside of the public right of way. 5. Prior to issuance of a grading permit the Final Grading and Drainage Plan shall show the accessibility path from the public right of way and the accessibility parking stalls to the building doors in conformance with the current adopted California Building Code. All accessibility ramps shall show sufficient detail including gradients, elevations, and dimensions and comply with the current adopted California Building Code. 6. The Grading and Drainage Plan shall implement City Standards for on -site construction where possible , and shall provide details for all work not covered by City Standard Drawings. 7. Prior to issuance of a grading permit, the grading and drainage plan shall show the maximum parking stall gradient at 5 percent. Accessibility parking stall grades shall be constructed per the, current adopted California Building Code. 8. The final grading and drainage plan shall show existing topography a minimum of 100-feet beyond project boundary. 9. This project shall comply with the accessibility requirements of the current adopted California Building Code. 10. www.CityofRC.us Page 6 of 11Printed: 4/10/2025    Page 44 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval Grading Inspections: a) Prior to the start of grading operations the owner and grading contractor shall request a pre -grading meeting. The meeting shall be attended by the project owner /representative , the grading contractor and the Building Inspector to discuss about grading requirements and preventive measures, etc. If a pre-grading meeting is not held within 24 hours from the start of grading operations, the grading permit may be subject to suspension by the Building Inspector; b) The grading contractor shall call into the City of Rancho Cucamonga Building and Safety Department at least 1 working day in advance to request the following grading inspections prior to continuing grading operations: i)The bottom of the over-excavation; ii)Completion of Rough Grading, prior to issuance of the building permit; iii)At the completion of Rough Grading, the grading contractor or owner shall submit to the Engineering Services Department an original and a copy of the Pad Certifications to be prepared by and properly wet signed and sealed by the Civil Engineer and Soils Engineer of Record; iv) The rough grading certificates and the compaction reports will be reviewed by the Associate Engineer or a designated person and approved prior to the issuance of a building permit. 11. Prior to issuance of a grading or building permit, the permitted grading plan (or architectural site plan ) set shall show in each of the typical sections and the plan view show how the separations between the building exterior and exterior ground surface meet the requirements of Sections CBC 1804.3/CRC R401.3, CBC2304.11.2.2/CRC R317.1(2) and CBC2512.1.2/CRC R703.6.2.1 of the current adopted California Building Code/Residential Code. 12. Prior to approval of the project -specific storm water quality management plan, the applicant shall submit to the City Engineer, or his designee, a precise grading plan showing the location and elevations of existing topographical features, and showing the location and proposed elevations of proposed structures and drainage of the site. 13. It shall be the responsibility of the applicant to acquire any required off -site drainage easements prior to the issuance of a grading permit. 14. Private sewer, water, and storm drain improvements will be designed per the latest adopted California Plumbing Code. Private storm drain improvements shall be shown on the grading and drainage plan. 15. Metropolitan Water District (MWD) shall approve all plans that impact their easement, including utilities , storm drain, slopes, and street trees and landscaping prior to issuance of a grading permit. A note shall be included on all pertinent plans requiring Metropolitan Water District Operations Maintenance Branch to be notified two working days prior to starting any work in the vicinity of their easement. 16. A permit shall be obtained from Metropolitan Water District (MWD) for any work within their right -of-way, including grading prior to issuance of a grading permit. 17. Prior to issuance of a grading permit the applicant shall obtain written comments from MWD regarding site design restrictions within their easement and provide a copy of said comments to the Building and Safety Official for review. 18. www.CityofRC.us Page 7 of 11Printed: 4/10/2025    Page 45 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval Prior to the issuance of the Certificate of Occupancy or final sign off by the Building Inspector the engineer of record shall certify the functionality of the storm water quality management plan (WQMP) storm water treatment devices and best management practices (BMP). 19. Prior to the issuance of a Grading Permit the City of Rancho Cucamonga’s “Memorandum of Agreement of Storm Water Quality Management Plan” shall be submitted for review and approval by the Building Official and recorded with the County Recorder’s Office . 20. Prior to issuance of a Grading Permit the applicant shall obtain a Waste Discharge Identification Number (WDID). The WDID number shall also be shown on the WQMP Site and Drainage Plan document. 21. The applicant shall provide a copy of a completed EPA Form 7520-16 (Inventory of Injection Wells) for each underground infiltration device, with the Facility ID Number assigned, to the Building and Safety Services Department Official prior to issuance of the Grading Permit and /or approval of the project-specific Water Quality Management Plan. A copy of EPA Form 7520-16 shall be scanned and pasted onto the permitted grading plan set, and a copy of said form shall be included in the project-specific Water Quality Management Plan . 22. The land owner shall provide an inspection report on a biennial basis for the structural storm water treatment devices, commonly referred to as BMPs, to the City of Rancho Cucamonga Environmental Program Manager. The land owner shall maintain on a regular basis as described in the Storm Water Quality Management Plan prepared for the subject project. All costs associated with the underground infiltration chamber are the responsibility of the land owner. 23. A final project-specific Storm Water Quality Management Plan (WQMP) shall be approved by the Engineering Services Department, and the City of Rancho Cucamonga’s “Memorandum of Storm Water Quality Management Plan” shall be recorded prior to the issuance of a grading permit or any building permit. 24. Prior to the issuance of a certificate of occupancy by the Building Official, or his designee, the civil engineer of record shall file a Water Quality Management Plan (WQMP) Post Construction Storm Water Treatment Devices As-Built Certificate with the Environmental Programs Coordinator, City of Rancho Cucamonga Engineering Services Department. 25. www.CityofRC.us Page 8 of 11Printed: 4/10/2025    Page 46 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval GROUND WATER PROTECTION: Prior to approval of the final project specific water quality management plan (WQMP), the WQMP document shall meet the requirements of the State Water Resources Control Board Order No . R8-2010-0036 (NPDES No. CAS 618036), the San Bernardino County Municipal Separate Storm Sewers Separation (MS4) Permit reads: Section XI.D(Water Quality Management Plan Requirements ).8(Groundwater Protection): Treatment Control BMPs utilizing infiltration [exclusive of incidental infiltration and BMPs not designed to primarily function as infiltration devices (such as grassy swales, detention basins, vegetated buffer strips, constructed wetlands, etc.)] must comply with the following minimum requirements to protect groundwater: a.Use of structural infiltration treatment BMPs shall not cause or contribute to an exceedance of ground water quality objectives. b.Source control and pollution prevention control BMPs shall be implemented to protect groundwater quality. The need for pre-treatment BMPs such as sedimentation or filtration should be evaluated prior to infiltration. c.Adequate pretreatment of runoff prior to infiltration shall be required in gas stations and large commercial parking lots. (NOTE: The State Water Quality Control Board defines a large commercial parking lot as ‘100,000 sq. ft. or more of commercial development to include parking lot (with 100 or more vehicle traffics ), OR, by means of 5,000sqft or more of allowable space designated for parking purposes’). d.Unless adequate pre -treatment of runoff is provided prior to infiltration structural infiltration treatment BMPs must not be used for areas of industrial or light industrial activity {77}, areas subject to high vehicular traffic (25,000 or more daily traffic ); car washes; fleet storage areas; nurseries; or any other high threat to water quality land uses or activities. e.Class V injection wells or dry wells must not be placed in areas subject to vehicular {78} repair or maintenance activities {79}, such as an auto body repair shop, automotive repair shop, new and used car dealership, specialty repair shop (e.g., transmission and muffler repair shop) or any facility that does any vehicular repair work. f.Structural infiltration BMP treatment shall not be used at sites that are known to have soil and groundwater contamination. g.Structural infiltration treatment BMPs shall be located at least 100 feet horizontally from any water supply wells. h.The vertical distance from the bottom of any infiltration structural treatment BMP to the historic high groundwater mark shall be at least 10-feet. Where the groundwater basins do not support beneficial uses, this vertical distance criteria may be reduced, provided groundwater quality is maintained. i.Structural infiltration treatment BMPs shall not cause a nuisance or pollution as defined in Water Code Section 13050. 26. www.CityofRC.us Page 9 of 11Printed: 4/10/2025    Page 47 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval NONRESIDENTIAL MANDATORY MEASURES – CALIFORNIA GREEN BUILDING STANDARDS CODE – Prior to the issuance of any building permit the applicant shall comply with Section 5.106.1 (Storm water pollution prevention) of the current adopted California Green Building Standards Code: Newly construction projects and additions which disturb less than one acre of land shall prevent the pollution of stormwater runoff from the construction activities through one or more of the following measures: 5.106.1.1 Local Ordinance – Comply with a lawfully enacted stormwater management and /or erosion control ordinance. 5.106.1.2 Best Management Practices (BMP) – Prevent the loss of soil through wind or water erosion by implementing an effective combination of erosion and sediment control and good housekeeping BMP. 1.Soil loss BMP that should be considered for implementation as appropriate for each project include , but are not limited to, the following: a.Scheduling construction activity. b.Preservation of natural features, vegetation and soil. c.Drainage swales or lined ditches to control stormwater flow. d.Mulching or hydroseeding to stabilize disturbed soils. e.Erosion control to protect slopes. f.Protection of storm drain inlets (gravel bags or catch basin inserts). g.Perimeter sediment control (perimeter silt fence, fiber rolls). h.Sediment trap or sediment basin to retain sediment on site. i.Stabilized construction exits. j.Wind erosion control. k.Other soil loss BMP acceptable to the enforcing agency . 2.Good housekeeping BMP to manage construction equipment, materials and wastes that should be considered for implementation as appropriate for each project include, but are not limited to, the following: a.Material handling and waste management. b.Building materials stockpile management. c.Management of washout areas (concrete, paints, stucco, etc.). d.Control of vehicle/equipment fueling to contractors staging area. e.Vehicle and equipment cleaning performed off site . f.Spill prevention and control. g.Other housekeeping BMP acceptable to the enforcing agency (City of Rancho Cucamonga). 27. www.CityofRC.us Page 10 of 11Printed: 4/10/2025    Page 48 Project #: DRC2023-00379 DRC2024-00288 Project Name: Cal Box II Location: 8949 TORONTO AVE - 020940105-0000 Project Type: Design Review Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval NONRESIDENTIAL MANDATORY MEASURES – CALIFORNIA GREEN BUILDING STANDARDS CODE – Prior to the issuance of any building permit the applicant shall comply with Section 5.106.10 (Grading and paving) of the current adopted California Green Building Standards Code: Construction plans shall indicate how site grading or a drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1.Swales. 2.Water collection and disposal systems . 3.French drains. 4.Water retention gardens . 5.Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 28. www.CityofRC.us Page 11 of 11Printed: 4/10/2025    Page 49