Loading...
HomeMy WebLinkAboutDELETE (4)RESOLUTION NO. 2025-031 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING HILLSIDE DEVELOPMENT REVIEW DRC2025-00106, A REQUEST TO CONSTRUCT AN APPROXIMATELY 6,201 SQUARE -FOOT, TWO- STORY SINGLE-FAMILY RESIDENCE WITH A 1,108 SQUARE -FOOT ATTACHED GARAGE ON A 22,888 SQUARE -FOOT UNDEVELOPED LOT WITHIN THE VERY LOW (VL) RESIDENTIAL ZONE WITH HILLSIDE AND EQUESTRIAN OVERLAYS LOCATED AT 10842 CARRIAGE DRIVE - APN: 1074-531-14 A. Recitals. 1. The applicant, Joud Construction, on behalf of the owner of the property, Nabeel Salhab, filed an application for approval of Hillside Development Review DRC2025-00106, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Hillside Development Review is referred to as "the application." 2. On the 8th day of October 2025, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on said application and concluded said hearing on that date. 3. All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2. Based upon the substantial evidence presented to this Commission during the above -referenced meeting on October 8th, 2025, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a. The application applies to the property currently addressed 10842 Carriage Drive, APN: 1074-531-14, generally located on the north side of Carriage Drive ; and b. The project site consists of a single 22,888 square foot parcel, which is currently vacant and unimproved; and C. The existing land uses on, and General Plan land use and zoning designations, for the project site and the surrounding properties, relative to the subject parcel, are as follows: PLANNING COMMISSION RESOLUTION NO. 2025-031 Hillside Development Review DRC2025-00106 City of Rancho Cucamonga October 81, 2025 Page 2 Land Use General Plan Zoning Semi -Rural Very Low (VL) Site Vacant Neighborhood Residential Zone* Semi -Rural Very Low (VL) North Single -Family Residence Neighborhood Residential Zone* Semi -Rural Very Low (VL) South - Vacant Neighborhood Residential Zone* Semi -Rural Very Low (VL) East Single -Family Residence Neighborhood Residential Zone* Semi -Rural Very Low (VL) West Single -Family Residence Neighborhood Residential Zone* * Hillside Overlay & Equestrian Overlay d. The application encompasses the construction of a 6,201 square -foot, two-story single-family residence with a 1,108 square -foot garage on the undeveloped 22,888 square -foot lot. The square footage is inclusive of a proposed 67 square -foot covered front porch, a 507 square -foot covered rear patio, a 308 square foot balcony, and a 400 square -foot cabana.; and e. Pursuant to Development Code section 17.16.140, new single-family residences in the Hillside Overlay require the approval of a Hillside Development Review. The approving authority for such applications is the Planning Director, except in the case where fill or excavation exceeds five feet in depth, in which case the Hillside Development Review will require approval from the Planning Commission as is described in section 17.122.020.G. The project proposes grading excavation of 15 feet in depth. The additional excavation past 5 feet is necessary to create a flat and usable pad, while adding elevated pads and retaining walls placed strategically upslope to conform to the natural grade. Furthermore, section 17.36.010.E.2 outlines that single-family, detached development is required to provide a minimum 400 square feet of flat and graded rear yard area. The proposed project provides this rear area as a patio and elevated pool and cabana pad; and f. The proposed single-family residence complies with each of the applicable development standards in the Very Low (VL) Residential Zone of the Development Code section 17.36.010-1A as well as the Hillside Overlay design standards in section 17.122.020 as follows: PLANNING COMMISSION RESOLUTION NO. 2025-031 Hillside Development Review DRC2025-00106 City of Rancho Cucamonga October 8'h, 2025 Page 3 Dbvelopmer t Standard - Proposed Permitted =. Compliant Building Mplight 29" 0" 30' Maximum Yes Front Setback 46'6" 42' Minimum Yes Side'Setba'cks 13'10" / 16'3" 10' / 15' Minimum Yes Rear Setback 70'3" 60' Minimum Yes Lot Coverage 24.79% 25% Maximum Yes Excavation 15' 5' Yes* * Subject to Planning Commission Approval 3. Based upon the substantial evidence presented to this Commission during the above -referenced meeting and upon the specific findings of facts set forth in Paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The proposed project is in accord with the General Plan, 'the objectives of the Development Code, and the purpose of the district in which the site is located. The General Plan land use designation of the project site is Semi -Rural Neighborhood. This land use designation is intended for the development of single-family residences. The project is for the construction of a single-family residence on a vacant, 22,888 square foot lot lot which is in keeping with the General Plan land use designation; and b. The proposed project is in accord with the purposes of the Development Code and of the zone in which the site is located. The Very Low (VL) Residential zone is for the development of semi -rural residential use with a minimum lot size of 20,000 square feet and a maximum residential density of up to two units per gross acre. The proposed single-family residence follows the intent of the Very Low (VL) Residential zoning designation with an existing lot size of 22,888 square feet and a residential density which does not exceed two units per gross acre. The proposed single-family residence is compliant with the development and design standards of the Hillside Overlay; and c. The proposed project complies with the applicable provisions of the Development Code. The proposed single-family residence complies with all standards of the Very Low (VL) Residential zone and Hillside Overlay as shown in Table 17.36.010-1A (Development Standards for Residential Zones) and Section 17.122.020 (Hillside Development) of the Development Code. Such standards include the design, setbacks, lot coverage, and building height; and d. The proposed use, together with the conditions applicable thereto, will not be detrimental to the public health, safety, or welfare, or materially injurious to properties or improvements in the vicinity. The proposed single-family residence complies with the PLANNING COMMISSION RESOLUTION NO. 2025-031 Hillside Development Review DRC2025-00106 City of Rancho Cucamonga October 811, 2025 Page 4 development criteria for the zone, the Hillside and Equestrian Overlays, and conforms to the development of the surrounding sites. Therefore, the project is not expected to be detrimental to the health, safety, or welfare of the general public or materially injurious to the properties or improvements in the vicinity. 4. Prior to any action being taken for this request, Planning Department staff has determined that the project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) and the City's CEQA Guidelines. The project qualifies for a Class 3 exemption under State CEQA Guidelines Section 15303 — New Construction or Conversion of Small Structures which includes the construction of one single-family residence in a residential zone. The project scope is for the construction of a 6,201 square -foot, two-story single-family residence with a 1,108 square -foot attached garage on a residentially zoned lot. Staff finds that there is no substantial evidence that the project will have a significant effect on the environment. 5. Based upon the findings and conclusions set forth in Paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each condition set forth in the Standard Conditions, attached hereto and incorporated herein by this reference. 6. The Secretary to this Commission shall certify the adoption of this Resolution. APPROVED AND ADOPTED THIS 8TH DAY OF OCTOBER 2025 PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: Ton orates, unairman ATTEST: �GQ J Wife akamura, Secretary I, Jennifer Nakamura, Secretary of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning'Commission of the City of Rancho Cucamonga, at a regular meeting,of the Planning Commission held on the 8th day of October 2025 by the following vote -to -wit: AYES: COMMISSIONERS: DOPP, WILLIAMS, MORALES, BOLING, DANIELS NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: RECUSE: COMMISSIONERS: Conditions of Approval RANCHO CUCAMONGA Community Development Department Project #: DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR - 107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT.• Planning Department Standard Conditions of Approval 1. The applicant shall sign the Statement of Agreement and Acceptance of Conditions of Approval provided by the Planning Department. The signed Statement of Agreement and Acceptance of Conditions of Approval shall be returned to the Planning Department prior to the submittal of grading/construction plans for plan check, request for a business license, and/or commencement of the approved activity. 2. The applicant shall indemnify, protect, defend, and hold harmless, the City, and/or any of its officials, officers, employees, agents, departments, agencies, those City agents serving as independent contractors in the role of City officials and instrumentalities thereof (collectively "Indemnitees"), from any and all claims, demands, lawsuits, writs of mandamus, and other actions and proceedings (whether legal, equitable, declaratory, administrative or adjudicatory in nature), and alternative dispute resolutions procedures (including, but not limited to, arbitrations, mediations, and other such procedures) (collectively "Actions"), brought against the City, and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof, that challenge, attack, or seek to modify, set aside, void, or annul, the action of, or any permit or approval issued by, the City and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof (including actions approved by the voters of the City), for or concerning the project, whether such actions are brought under the California Environmental Quality Act (CEQA), State Planning and Zoning Law, the Subdivisions Map Act, Code of Civil Procedure Section 1085 or 1094.5, or any other state, federal, or local statute, law, ordinance, rule, regulation, or any decision of a competent jurisdiction. This indemnification provision expressly includes losses, judgments, costs, and expenses (including, without limitation, attorneys' fees or court costs) in any manner arising out of or incident to this approval, the Planning Director's actions, the Planning Commission's actions, and/or the City Council's actions, related entitlements, or the City's environmental review thereof. The Applicant shall pay and satisfy any judgment, award or decree that may be rendered against City or the other Indemnitees in any such suit, action, or other legal proceeding. It is expressly agreed that the City shall have the right to approve, which approval will not be unreasonably withheld, the legal counsel providing the City's defense, and that the applicant shall reimburse City for any costs and expenses directly and necessarily incurred by the City in the course of the defense. City shall promptly notify the applicant of any Action brought and City shall cooperate with applicant in the defense of the Action. In the event such a legal action is filed challenging the City's .determinations herein or the issuance of the approval, the City shall estimate its expenses for the litigation. The Applicant shall deposit said amount with the City or, at the discretion of the City, enter into an agreement with the City to pay such expenses as they become due. www.CityofRC.us Printed: 9/25/2025 Page 16 Project #: DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR - 107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT. Planning Department Standard Conditions of Approval 3. Copies of the signed Planning Commission Resolution of Approval or Approval Letter, Conditions of Approval, and all environmental mitigations shall be included on the plans (full size). The sheet(s) are for information only to all parties involved in the construction/grading activities and are not required to be wet sealed/stamped by a licensed Engineer/Architect. 4. The applicant shall be required to pay California Department of Fish and Wildlife Notice of Exemption fee in the amount of $50.00. All checks are to be made payable to the Clerk of the Board Supervisors and submitted to the Planning Commission Secretary prior to public hearing or within 5 days of the date of project approval. 5. Any approval shall expire if Building Permits are not issued or approved use has not commenced within 2 years from the date of approval or a time extension has been granted. 6. A detailed landscape and irrigation plan, including slope planting and model home landscaping in the case of residential development, shall be prepared by a licensed landscape architect and submitted for Planning Director review and approval prior to the issuance of Building Permits for the development or prior final map approval in the case of a custom lot subdivision. For development occurring in the Very High Fire Hazard Severity Zone, the landscape plans will also be reviewed by Fire Construction Services. 7. Tree maintenance criteria shall be developed and submitted for Planning Director review and approval prior to issuance of Building Permits. These criteria shall encourage the natural growth characteristics of the selected tree species. 8. All walls shall be provided with decorative treatment. If located in public maintenance areas, the design shall be coordinated with the Engineering Services Department. 9. Approval of this request shall not waive compliance with all sections of the Development Code, all other applicable City Ordinances, and applicable Community, Specific Plans and/or Master Plans in effect at the time of Building Permit issuance. 10. All building numbers and individual units shall be identified in a clear and concise manner, including proper illumination and in conformance with Building and Safety Services Department standards, the Municipal Code and the Rancho Cucamonga Fire Department (RCFD) Standards. 11. The site shall be developed and maintained in accordance with the approved plans which include Site Plans, architectural elevations, exterior materials and colors, landscaping, and grading on file in the Planning Department, the conditions contained herein, and the Development Code regulations. 12. All parkways, open areas, and landscaping shall be permanently maintained by the property owner, homeowners' association, or other means acceptable to the City. Proof of this landscape maintenance shall be submitted for Planning Director and Engineering Services Department review and approved prior to the issuance of Building Permits. 13. Where corner side, interior side or rear yard property lines are adjacent to local construct minimum 6-foot high decorative masonry walls. Decorative masonry shall double sided block, 'slump stone' or an alternative material that is acceptable to th e Printed: 9125/2025 www.CityofRC.us Page 2 of B Page 17 Project #: DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR - 107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planninct Department Standard Conditions of Approval 14. Occupancy of the facilities shall not commence until such time as all California Building Code and State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety Services Department to show compliance. The buildings shall be inspected for compliance and final acceptance granted prior to occupancy. 15. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for consistency prior to issuance of any permits (such as grading, tree removal, encroachment, building, etc.) or prior to final map approval in the case of a custom lot subdivision, or approved use has commenced, whichever comes first. 16. Prior to any use of the project site or business activity being commenced thereon, all Conditions of Approval shall be completed to the satisfaction of the Planning Director. 17. Revised Site Plans and building elevations incorporating all Conditions of Approval shall be submitted for Planning Director review and approval prior to the issuance of Building Permits. Enaineerina Services Department Please be advised of the following Special Conditions 1. Development Impact Fees Due Prior to Building Permit Issuance or Certificate of Occupancy (Note: Development Impact Fees placed are subject to change annually) Drainage Impact Fee. Transportation North Zone Library Impact Fee Animal Center Impact Fee Police Impact Fee Park Land Impact Fee Park Improvement Impact Fee Community & Recreation Center Facilities Impact Fee 2. Create separate ENG permit through ACCELA. Revise existing street improvement plans (DWG 1289) to the satisfaction of the City Engineer. Plan shall include street trees, street lights, and any other mentioned in COAs. Plan shall be prepared by a registered Civil Engineer and approved by the City Engineer. Plan check fees apply. Standard Conditions of Approval 3. Permits shall be obtained from the following agencies for work within their right of way: City of Rancho Cucamonga Engineering Services Department Cucamonga Valley Water District www.CityofRC.us Printed: .9/2512025 Page 3 of 8 Page 18 Project M DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR - 107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT.• Engineering Services Department Standard Conditions of Approval 4. Construct the following perimeter street improvements including, but not limited to: 1. Carriage Drive: Drive Appr. Street Trees Curb Drain (will need it if there is a drainage on site) 5. Improvement Plans and Construction: a. Street improvement plans, including street trees, street lights, and any other list on here shall be prepared by a registered Civil Engineer and shall be submitted to and approved by the City Engineer. Prior to final map approval or the issuance of Building Permits, whichever occurs first. b. Prior to any work being performed in public right-of-way, fees shall be paid and a construction permit shall be obtained from the Engineering Services Department in addition to any other permits required. c. Concentrated drainage flows shall not cross sidewalks. Under sidewalk drains shall be installed to City Standards. 6. Install street trees per City street tree design guidelines and standards as follows. The completed legend (box below) and construction notes shall appear on the title page of the street improvement plans. Street improvement plans shall include a line item within the construction legend stating: "Street trees shall be installed per the notes and legend on Sheet _ (typically Sheet 1)." Where public landscape plans are required, tree installation in those areas shall be per the public landscape improvement plans. - Carriage Drive Per City approved Street tree list Construction Notes for Street Trees: 1) All street trees are to be planted in accordance with City standard plans. 2) Prior to the commencement of any planting, an agronomic soils report shall be furnished to the City inspector. Any unusual toxicities or nutrient deficiencies may require backfill soil amendments, as determined by the City inspector. 3) All street trees are subject to inspection and acceptance by the Engineering Services Department. Street trees are to be planted per public improvement plans only. 7. Street improvement plans per City Standards for all private streets shall be provided for review and approval by the City Engineer. Prior to any work being performed on the private streets, fees shall be paid and construction permits shall be obtained from the Engineering Services Department in addition to any other permits required. Printed: 9/25I2025 www.CityofRC.us Page 4 of 8 Page 19 Project #: DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR - 107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT. Engineering Services Department Standard Conditions of Approval 8. All public improvements (interior streets, drainage facilities, community trails, paseos, landscaped areas, etc.) shown on the plans and/or tentative map shall be constructed to City Standards. Interior street improvements shall include, but are not limited to, curb and gutter, AC pavement, drive approaches, sidewalks, street lights, and street trees. 9. Street trees, a minimum of 15-gallon size or larger, shall be installed per City Standards in accordance with the City's street tree program. 10. This parcel is required to be annexed into CFD 2022-01 to finance the maintenance and services of streetlights, traffic lights, and appurtenant facilities. This condition needs to be completed before the Final Map approval or issuance of Building Permits whichever occurs first. Any annexation cost shall be borne by the developer. To start the CFD annexation process, please contact Kelly Guerra at 909-774-2582. To start the LIVID annexation process, please contact your plan examiner at 909-774-4028. Grading Section Standard Conditions of Approval 1. Grading of the subject property shall be in accordance with current adopted California Building Code and/or the California Residential Code, City Grading Standards, and accepted grading practices. The Grading and Drainage Plan(s) shall be in substantial conformance with the approved conceptual Grading and Drainage Plan. 2. A soils report shall be prepared by a qualified Engineer licensed by the State of California to perform such work. Two copies will be provided at grading and drainage plan submittal for review. Plans shall implement design recommendations per said report. 3. The final Grading and Drainage Plan, appropriate certifications and compaction reports shall be completed, submitted, and approved by the Building and Safety Official prior to the issuance of building permits. 4. A separate Grading and Drainage Plan check submittal is required for all new construction projects and for existing buildings where improvements being proposed will generate 50 cubic yards or more of combined cut and fill. The Grading and Drainage Plan shall be prepared, stamped, and wet signed by a California licensed Civil Engineer prior to the issuance of a grading or building permit. 5. Prior to the issuance of a grading permit the applicant shall obtain written permission from the adjacent property owner(s) to construct wall(s) on property line(s) or provide a detail(s) showing the perimeter wall(s) to be constructed offset from the property line. 6. Prior to issuance of a grading permit the grading plan shall show that all manufactured slopes shall be a minimum 2-foot offset from the public right of way, permitted line, or the adjacent private property. All slope offsets shall meet the requirements of the current adopted California Building Code. 7. The final grading and drainage plan shall show existing topography a minimum of 100-feet beyond project boundary. Printed: 9/25/2025 www.CilyofRC.us Page 5 of 5 Page 20 Project #: DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR - 107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT. - Grading Section Standard Conditions of Approval 8. Grading Inspections: a) Prior to the start of grading operations the owner and grading contractor shall request a pre -grading meeting. The meeting shall be attended by the project owner/representative, the grading contractor and the Building Inspector to discuss about grading requirements and preventive measures, etc. If a pre -grading meeting is not held within 24 hours from the start of grading operations, the grading permit may be subject to suspension by the Building Inspector; b) The grading contractor shall call into the City of Rancho Cucamonga Building and Safety Department at least 1 working day in advance to request the following grading inspections prior to continuing grading operations: i) The bottom of the over -excavation; ii) Completion of Rough Grading, prior to issuance of the building permit; iii) At the completion of Rough Grading, the grading contractor or owner shall submit to the Permit Technicians (Building and Safety Front Counter) an original and a copy of the Pad Certifications to be prepared by and properly wet signed and sealed by the Civil Engineer and Soils Engineer of Record; iv) The rough grading certificates and the compaction reports will be reviewed by the Associate Engineer or a designated person and approved prior to the issuance of a building permit. 9. Prior to issuance of a grading or building permit, the permitted grading plan (or architectural site plan) set shall show in each of the typical sections and the plan view show how the separations between the building exterior and exterior ground surface meet the requirements of Sections CBC 1804.3/CRC R401.3, CBC2304.11.2.2/CRC R317.1(2) and CBC2512.1.2/CRC R703.6.2.1 of the current adopted California Building Code/Residential Code. 10. The proposed private sewage disposal (septic) system shall be located in the front yard to allow a future connection to a public sewer main. 11. The conceptual grading and drainage plan is showing driveway slopes exceeding 10%. Therefore, prior to issuance of a grading permit, the permitted grading plan set shall show driveway profiles for the circular driveway from the street curb line to the garage door(s). 12. Private sewer, water, and storm drain improvements will be designed per the latest adopted California Plumbing Code. Private storm drain improvements shall be shown on the grading and drainage plan. 13. Prior to the issuance of the Certificate of Occupancy or final sign off by the Building Inspector the engineer of record shall certify the functionality of the storm water quality management plan (WQMP) storm water treatment devices and best management practices (BMP). 14. Prior to approval of the Water Quality Management Plan (WQMP), the WQMP shall include a copy of the project Conditions of Approval. Printed: 9/25/2625 www.CityofRC.us Page 6 of 8 Page 21 Project #: DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR - 107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval 15. This application for storm water quality management plan purposes may be considered a non -priority project. Therefore, prior to issuance of any building permit or Engineering Services Department issued right of way permit the land owner with the applicant shall file a Non -Priority Water Quality Management Plan (WQMP) with the Building and Safety Department. The applicant may contact Matthew Addington, Associate Engineer, at (909) 477-2710, extension 4202. This project is required to prepare a non -priority WQMP project as the following requirement has been met: i) For areas less than 2,000 square feet of impervious area, the development will be considered a non -priority project and a WQMP document is not required, unless the project is for the outdoor storage of hazardous materials or other materials which may require a pre-treatment of the storm water runoff which will require that a non -priority WQMP document is prepared, including but not limited to, vehicle fueling operations; ii) For significant re -development projects proposing impervious areas of 2,000 square feet to 4,999 square feet and new development projects proposing impervious areas of 2,000 square feet to 9,999 square feet the following criteria will require a non -priority WQMP document to be prepared: a. For all new and significant redevelopment projects; b. If the project is part of a common area of development, a non -priority WQMP document shall be prepared; c. If the proposed development is a commercial project the City will determine if activities may impact the water quality, and if impacts are determined to affect the water quality a non -priority WQMP document will be prepared; d. All industrial projects will require a non -priority WQMP document to be prepared. 16. RESIDENTIAL. MANDATORY MEASURES - CALIFORNIA GREEN BUILDING STANDARDS CODE - Prior to the issuance of any building permit the applicant shall comply with Section 4.106.2 (Storm water drainage and retention during construction) of the current adopted California Green Building Standards Code: Projects which disturb less than one (1) acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency (City of Rancho Cucamonga). 3. Compliance with a lawfully enacted storm water management ordinance. Printed: 9/25/2025 www.CityofRC.us Page 7 of B Page 22 Project #: DRC2025-00106 Project Name: Joud Construction Location: 10842 CARRIAGE DR-107453114-0000 Project Type: Hillside Development Review ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval 17. RESIDENTIAL MANDATORY MEASURES — CALIFORNIA GREEN BUILDING STANDARDS CODE — Prior to the issuance of any building permit the applicant shall comply with Section 4.106.3 (Grading and Paving) of the current adopted California Green Building Standards Code: Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering building. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales. 2. Water collection and disposal systems. 3. French drains. 4. Water retention gardens. 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. Printed: 9/25/2025 www.cityofRC.us Page 8 of 8 Page 23