Loading...
HomeMy WebLinkAbout03-17 - Agenda Packet contact the Planning Department at (909) 477-2750. Notification of 48 hours prior to the meeting will enable the City to make reasonable arrangements to ensure accessibility. Listening devices are available for the hearing impaired. ` MARCH 17, 2026- 6:00 P.M. DESIGN REVIEW COMMITTEE MEETING AGENDA RAINS ROOM CITY HALL 10500 Civic Center Drive Rancho Cucamonga, CA 91730 A. Call to Order Roll Call: Chairman Al Boling Commissioner Tony Morales B. Public Communications This is the time and place for the general public to address the Committee on any item listed or not listed on the agenda. The Committee may not discuss any issue not included on the agenda but set the matter for a subsequent meeting. C. Consent Calendar Consideration to Adopt Meeting Minutes of January 20, 2026. (No meetings were held on February 3, February 17 and March 3, 2026) D. Project Review Items – A request for the design review of a proposed 4,910 square foot express car wash to be constructed on a vacant 1.05 acre parcel of land within the Corridor 1 (CO1) zone, located at 8172 Vineyard Avenue, generally to the southwest of the intersection of Vineyard Avenue and Foothill Boulevard. (APN: 0207-211- Guidelines Section 15332 – Infill Development Projects. (Conditional Use Permit DRC2025- 00113, Minor Design Review DRC2025-00118, Variance DRC2026-00074). E. Adjournment The Design Review Committee has adopted Administrative Regulations that set a 9:00 p.m. adjournment time. If items go beyond that time, they shall be heard only with the consent of the Committee. I, Elizabeth Thornhill, Executive Assistant of the City of Rancho Cucamonga, or my designee, hereby certify that a true, accurate copy of the foregoing agenda was posted seventy-two (72) hours prior to the meeting per Government Code 54954.2 at 10500 Civic Center Drive, Rancho Cucamonga, California and on the City’s website. Design Review Committee Meeting Agenda January 20, 2026 DRAFT MINUTES Rancho Cucamonga, CA 91730 6:00 p.m. A. Call to Order The meeting of the Design Review Committee was held on January 20, 2026. The meeting was called to order by Caleb Richards, Staff Facilitator, at 6:00 p.m. Design Review Committee members present: Chairman Boling and Vice Chairman Daniels and Caleb Richards Staff Present: Haide Aguirre, Contract Planner; Aracely Estrada, Management Analyst II B. Public Communications Staff Facilitator opened the public communication and after noting there were no public comments, closed public communications. C. Consent Calendar Consideration to adopt Special Meeting Minutes of November 4th Item C1. Motion carried 3-0 vote as amended and posted online. D. Project Review Items NEWBRIDGE HOMES – A request to merge six undeveloped lots totaling 415,562 square feet (9.54 acres) into two lots and construct a mixed-use development with 180 residential units on approximately 8.69-acres (Lot 1) and 8,100 square feet of commercial space on approximately 0.68-acres (Lot 2) within the Center 1 (CE1) Zone, located at the northeast corner of Etiwanda Avenue and Baseline Road (12906-13042 Baseline Road); APN: 0227-131-17, -38, -39, -46, -50, and -51. This item is exempt from the requirements of the California Environmental Quality Act (CEQA) pursuant to Public Resources Code Section 21080.66. (SUBTT20790 and DRC2024- 00429). Staff presented the item to the Design Review Committee. The applicant was present. No members of the public were in attendance. Committee Members provided the following comments: Confirmed that staff would correct the project area on the Staff Report from 9.54 acres to 9.37 acres; asked staff to clarify the project’s parking ratio; recommended that staff coordinate with the Engineering Department on traffic signage at Shelby Place; consider a parking waiver to reduce the parkway width and increase the sidewalk width improvements are consistent with existing conditions); consider revisions to the S-tile roofing to align with a contemporary architectural style; recommended highlighting the grade differential between the school site and the proposed project to further demonstrate the presence of a buffer; and concerns were raised regarding potential incompatibility between existing zoning and particularly on Shelby Place (applicant explained that attempts were made to acquire the parcels to the north however the property owners were not interested in selling). Committee Members inquired about the following: The anticipated market rate pricing- applicant stated that the pricing has not been determined; how will the nine very low income units be distributed- applicant confirmed that they units will be evenly distributed pursuant to the State Density Bonus Law; requested clarification on the waiver allowing an increased grade differential for the non-residential parcel- applicant explained that the Center 1 Form Based Code presents topography constraints and the waiver would allow a grade increase of up to 4.5 feet to accommodate site conditions; will the utilities be underground at Etiwanda Avenue and Base Line Road and will the Engineering Department include a condition to include high speed fiber optic infrastructure- applicant confirmed that the utilities will be installed underground; how will the parking be monitored- applicant stated that parking enforcement will be managed by the Homeowners Association; will the commercial parcel be retained or sold- applicant stated that the intent is to retain ownership; noted that the private open space appears narrow and requested clarification- applicant explained that while the minimum square footage was met, the dimensions were constrained by the site configuration; and lastly, clarification was requested on the color palettes to which the applicant presented color samples. The Design Review Committee voted to move the project forward to the Planning Commission with a recommendation of approval. Recommended approval to PC. 3-0 Unanimous Votes. E. Adjournment Staff Facilitator Richards adjourned the meeting at 7:04 p.m. Respectfully submitted, ___________________________ Elizabeth Thornhill, Executive Assistant DESIGN REVIEW COMMENTS March 17th, 2026 6:30 p.m. Jared Knight, Assistant Planner CONDITIONAL USE PERMIT, MINOR DESIGN REVIEW – A&S ENGINGEERING, INC – A request for the design review of a proposed 4,910 square foot express car wash to be constructed on a vacant 1.05 acre parcel of land within the Corridor 1 (CO1) zone, located at 8172 Vineyard Avenue, generally to the southwest of the intersection of Vineyard Avenue and Foothill Boulevard. (APN: 0207-211-48). This application is categorically exempt from the requirements of the California Environmental Quality Act (CEQA) under State CEQA Guidelines Section 15332 – Infill Development Projects. (Conditional Use Permit DRC2025-00113, Minor Design Review DRC2025-00118, Variance DRC2026-00074) Site Characteristics and Background: The project site is a vacant parcel approximately 1.05 acres in size, located generally to the southwest of the intersection of Vineyard Avenue and Foothill Boulevard. The majority of the project site is covered with low-lying vegetation consisting of grass and weeds and also features an existing paved area in the rear of the parcel, to be removed and replaced. An aerial image of the project site is provided in figure 1. Figure 1 - Aerial Image of Project Site DRC COMMENTS DRC2024-00118 – A&S Engineering Inc March 17th, 2025 Page 2 Land Uses: The existing Land Use, General Plan, and Zoning Designations for, the project site and the surrounding properties are as follows: Land Use General Plan Zoning Site North Multi-Tenant Commercial City Corridor Moderate Corridor 1 (CO1) South Multi-Family Residential Suburban Neighborhood Low Medium Residential (M) East Multi-Family Residential City Corridor Moderate Corridor 1 (CO1) West Project Overview, Architecture, Building Plotting, and Site Layout: The project is for the development of a self-service car wash facility, consisting of a single 4,910 square foot building with frontage on Vineyard Avenue, which includes a 2200 square foot wash tunnel, an attached 1,210 square foot equipment room, and an attached 1500 square foot polish tunnel. 18 vacuum stations are proposed behind the primary building. Images of the proposed elevations of the project are provided in figures 2 and 3. Additional improvements proposed include a 238-square-foot, 6.5-foot-tall equipment room serving the proposed vacuum stations, and two restrooms. One restroom shall be located adjacent to the service kiosk and will be 130 square feet in area and 12 feet in height, while the other unisex restroom shall be located adjacent to the vacuum stations and shall be 70 square feet in area and 12 feet in height. Figure 2 - Proposed East/West Elevations DRC COMMENTS DRC2024-00118 – A&S Engineering Inc March 17th, 2025 Page 3 Figure 3 - Proposed North/South Elevations Access to the car wash will be provided from Vineyard Avenue and shared with the multitenant commercial center to the north and the vacant parcel to the west. Vehicles shall move south along the west side of the property in a single drive aisle before turning at the southwestern corner. Along the southern edge of the property, the drive aisle splits into two lanes, one allowing access to the car wash facility, while the other allows vehicles to exit the property via one-way access to Vineyard Avenue. Vehicles which go through the car wash facility shall exit the property via the northern access. To protect the existing residential properties to the south and potential future residential properties to the west from noise produced by the car wash facility’s operations, a six-foot masonry wall is proposed along the western and southern edges of the property. Parking: Section 17.64.050 (Number of Parking Spaces Required) of the Development Code requires self-service carwash facilities to provide 2.5 parking spaces per wash bay. The proposed project provides a total of 3 on-site parking spaces. There are 18 spaces with vacuum stations that customers can use to hand dry and vacuum cars. Additionally, the project adjoins with a neighboring multi-tenant commercial center with approximately 110 shared parking spaces. Thus, planning staff finds that the proposed project satisfies the code requirements for parking. Compliance with Development Standards: The project is within the Corridor 1 zone and the development standards for the zone are shown in the following table: DRC COMMENTS DRC2024-00118 – A&S Engineering Inc March 17th, 2025 Page 4 Corridor 1 (CO1) Zone Development Standards Required Proposed Compliant Dwelling Units 24/Acre Minimum 0 Yes* Build-to Line 15 Minimum 15 Yes Minimum Percentage of Frontage Width 80% 43% Yes* Minimum Ground Floor Nonresidential 15 feet 30 feet Yes Maximum Building Stories 4 Stories 1 Story Yes Minimum Parking Setback 40 feet 85 Feet Yes *With Variance, see discussion below Staff notes that an existing sidewalk easement exists on the east side of the property preventing the proposed carwash from meeting the 15-foot build-to-line maximum. As a condition of approval, this easement shall be vacated, and the proposed building moved forward five feet during the plan check process. Pursuant to Development Code Section 17.130.060, the proposed carwash is to be classified under the “Mid-Rise” Building Type. The development standards for the Mid-Rise Building Type are shown in the following table. Mid-Rise Building Type Development Standards Required Proposed Compliant Site Width 257 feet Yes Site Depth Min 150 feet Max 400 feet 174 feet Yes Rear Yard Setback Minimum 10 Feet 10 feet Yes Building Height Max 80 Feet 30 Feet Yes Building Width Max 400 110 Feet Yes Building Depth Max 390 56 Feet Yes Variance: The project is consistent with the development requirements for the Corridor 1 Zone except for a few site-specific conditions requiring Variances. The first variance request relates to the minimum residential development of 24 units per acre within the Corridor 1 Zone. Due to the nature of the proposed car wash use and the small size of the project site, it would not be feasible for both the car wash and residential development to take place on the site. Furthermore, the vacant property to the west is entitled with a 158-unit residential development under DRC2022-00189, with which the proposed car was shall share access from Vineyard Avenue. Thus, the proposed car wash is considered part of an existing larger horizontal mixed-use project. DRC COMMENTS DRC2024-00118 – A&S Engineering Inc March 17th, 2025 Page 5 The second variance request relates to the minimum percentage of the lot width that the building frontage must occupy. Due to the circulation needs of the proposed use, and the size of the project site, it is not feasible to widen the proposed frontage. These requests are the minimum necessary to address physical constraints beyond the applicant’s control while maintaining functional site layout and consistency with the City Standards. A summary of Variances requested are shown in the table below: Summary of Variance Request Condition Request Deviation Constraint Residential Requirement No Residential Element Size of site does not allow for feasible mixed-use development Minimum Percentage of Frontage Width >80% of Frontage Width Size of site does not allow for wider frontage while meeting circulation needs. Conditional Use Permit: Pursuant to Development Code Section 17.136.020 (Table 17.136.020- 1), a conditional use permit is required to operate a “Car Washing and Detailing” use within the Corridor 1 zone. Appropriately, the applicant has applied for a conditional use permit for the proposed car wash, which has been reviewed concurrently with the subject design review. Landscaping: The project provides a total of 14,840 square feet of landscaped area. Shrubbery is to be planted along the perimeter of the project site, which together with the proposed masonry wall will screen the vacuum stations from view of the adjacent residential properties, in accordance with Development Code Section 17.90.020E. In addition, a total of 70 trees are proposed to be planted on the project site, primarily on the perimeter of the site further screen the vacuum stations and drive aisles from view. Notably, all species of vegetation proposed for the project have a rating of “low” or “very low” water usage, based on the Water Use Classification of Landscape Species (WUCOLS) list. The proposed landscaping plan is provided in figure 3. DRC COMMENTS DRC2024-00118 – A&S Engineering Inc March 17th, 2025 Page 6 Figure 4 - Landscape Plan Staff Recommendation: The project is consistent with the City Corridor Moderate General Plan designation and the standards of the Corridor 1 (CO1) zoning designation. The requested variances are limited, tied to lot size restrictions and limited frontages, and represent the minimum relief needed while protecting public health, safety and welfare. The project makes creative use of an existing vacant parcel. Staff has been discussing the possibility of enhancing the east elevation with public art or other treatments to reduce the flatness of the elevation. The applicant is very open to this idea and will continue to work with staff on final details. Staff requests that the Design Review Committee consider the design (building architecture, site planning, etc.) of the proposed project and recommend the selected action below: ☒Recommend Approval of the design of the project as proposed by the applicant. ☐Recommend Approval with Modifications to the design of the project by incorporating revisions requested by the Committee. Follow-up review by the Committee is not required. The revisions shall be verified by staff prior to review and action by the Planning Director / Planning Commission. ☐Recommend Conditional Approval of the design of the project by incorporating revisions requested by the Committee. Follow-up review by the Committee is not required. The revisions shall be Conditions of Approval and verified by staff during plan check after review and action by the Planning Director / Planning Commission. ☐Recommend Denial of the design of the project as proposed by the applicant. DRC COMMENTS DRC2024-00118 – A&S Engineering Inc March 17th, 2025 Page 7 Design Review Committee Action: Staff Planner: Jared Knight, Assistant Planner Members Present: Staff Coordinator: Aracely Estrada, Management Analyst Exhibit A – Project Plans PROJECT DATA SCOPE OF WORK T1 COVER SHEET PS1-1 SITE PLAN D-1 DEMOLITION PLAN A2.0 PROPOSED FLOOR PLAN A2.1 EXTERIOR ELEVATIONS A2.2 EXTERIOR ELEVATIONS TE1 TRASH ENCLOSURE PLAN, ELEVATION & SECTION SHEET INDEX CIVIL SHEET 1 OF 3 PRELIMINARY GRADING AND DRAINAGE PLAN SHEET 2 OF 3 PRELIMINARY WQMP SHEET 3 OF 3 PRELIMINARY UTILITY PLAN LANSCAPE PL-1 PRELIMINARY LANDSCAPE PLAN DO NOT ENTER ESCA P E LANE DO NOT ENTER DO NOT ENTER PROPERTY LINE PROPERTY LINE FENCE WALL S00°00'00"E 272.66' S8 9 ° 5 2 ' 3 0 " E 81 . 8 7 ' S8 9 ° 5 2 ' 3 0 " E 96 . 0 0 ' S8 9 ° 5 2 ' 3 0 " E 14 . 0 0 ' N8 9 ° 5 2 ' 3 0 " W 14 . 0 0 ' N8 9 ° 5 2 ' 3 0 " W 17 . 0 0 ' N00°13'40"E 474.47' N00°13'40"E 90.00' N00°13'40"E 90.00' EXISTING WATER VALVE EXISTING SEWER MANHOLE EXISTING WATER METER EXISTING WATER VALVE EXISTING SEWER MANHOLE CONNECT TO SEWAGE DISPOSAL ℄ EXISTING DRIVEWAY 1 2 3 4 5 6 7 8 1 7 3 7 5 5 5 PROPERTY LINE PROPERTY LINE FENCE WALL COLOR LEGEND FINISH MATERIAL KEYED NOTES COLOR LEGEND FINISH MATERIAL KEYED NOTES S S SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSS W W W W W W W W W W W W W W W W W W W W W W W W W W W W SD SD SD SD SD SD SD SD SD SD VINEYARD AVE. VINEYARD AVE (20) (16) (17) (18) (19) (19) (1 9 ) (19) (19) (21) (22) (23 )(23) (23) (23) (2 3 ) (2 4 ) (15) (20) (13) (13) (14)(14) (14)(14) (14) (16) (1 7 ) (1 8 ) (19) (2 1 ) (21) (21) (1 5 ) (2 0 ) (20)(20) (2 0 ) (20) (14) (1 6 ) (17) (18) (19) (20) (19) (19) (19) (2 1 ) 7 5 1 3 5 5 DO NOT ENTER TE <<<<< VACUUM EQUIPMENT ROOM POLISH TUNNEL FF = 18.18 EQUIPMENT ROOM FF = 18.18 CARWASH TUNNEL FF = 17.68 DO NOT ENTER DO NOT ENTER < KIOSK FF = 17.65 MATCH EXISTING CURB HEIGHT UNDERGROUND CMP CDS UNIT CURB DRAIN P/L P/L P/L P/L N00°00'00"E 269.80' N8 9 ° 5 2 ' 3 0 " W 1 7 7 . 8 7 ' N00°13'40"E 90.00' N00°13'40"E 173.10' N8 7 ° 3 0 ' 2 1 " W 1 6 2 . 0 7 ' N8 9 ° 5 2 ' 3 0 " W 17 . 0 0 ' JOIN EXISTING GB GB GB GB GB GB GB GB GB GB R R PROPOSED 6' HIGH MIN. SOLID MASONRY WALL 18" MAX STEM WALL 20 18 19 20 18 19 21 18 19 20 21 22 20 18 1818 19 17 15 14 141414 16 1.5 6 % 1.65% 2. 5 3 % 4.04% 4.21 % 5.97% 4.90% 2.51% 3.92% 3.4 3 % 6. 4 2 % 1.49% 3.1 7 % 1.9 4 % 2. 8 8 % 1.5 1 % 3.31% 1.5 9 % 2.4 9 % 0.6 7 % 1.53 %4.0 9 % 1.83% 5.26% 1. 6 5 % 2.6 1 % 5.3 4 % 9. 9 4 % 11 . 1 2 % 12 . 2 4 % 0. 6 0 % 0. 7 1 % 7. 7 5 % 5. 1 0 % 1.64% 1.03% 1.45% 1.12% 0. 6 3 % 0.83% 1.57 % 1.00% 1.50% 1.50% 1.44% 1. 1 6 % 1.00% 1.16% 1. 4 9 % 0.72 % 6. 1 1 % 1.50% 6. 4 8 % 0.65% 0. 5 0 % 1.96% 3.35% PROPOSED 6' HIGH MIN. SOLID MASONRY WALL 9.27 % 18.09 TC 17.59 FL 18.47 TC 17.97 FS 23.36 TC 22.86 FS (22.43) FS (23.02) TC 22.99 TC 22.49 FS 21.71 TC 21.21 FS 20.57 TC 20.07 FS 19.01 TC 18.51 FS 18.44 TC 17.94 FS 18.29 TC 17.79 FS 18.97 TC 18.47 FS 18.00 TC 17.50 FS 18.23 TC 17.73 FS 16.94 TC 16.44 FL 16.75 TC 16.25 FL 12.98 TG 16.85 TC 16.35 FS 17.87 TC 17.37 FS 18.09 TC 17.59 FL 18.41 TC 17.91 FS 17.68 DOOR 18.18 DOOR ??? DOOR 18.18 DOOR 17.68 DOOR 18.18 DOOR 17.51 TG 18.71 TC 18.21 FS 18.62 TC 18.12 FS 19.82 TC 19.32 FS 19.73 TC 19.23 FS 21.24 TC 20.74 FS 22.42 TC 21.92 FS 18.90 TC 18.40 FS 17.88 TC 17.38 FS 13.18 TG 18.14 TC 17.64 FS 19.01 TC 18.51 FL 19.40 TC 18.90 FS 18.44 TC 17.94 FS 19.90 TC 19.40 FS 20.15 TC 19.65 FS19.21 TC 18.71 FS 18.48 TC 17.98 FS 19.21 TC 18.71 FS 18.13 TC 17.63 FS 17.78 TC 17.28 FL 20.11 TC 19.61 FS 19.70 TC 19.20 FS 18.84 FS 17.55 TC 17.05 FS (13.04) FS (22.76) FS JOIN EXISTING GB 0.69% OF 3 SHEETS SHEET DATE: JOB NO.25021 11/6/2025 W: \ 2 5 - 0 2 1 c a r w a s h r a n c h o c u c a m o n g a \ D W G \ 2 5 0 2 1 P 0 1 P G . d w g N o v 0 6 , 2 0 2 5 - 1 1 : 2 2 a m CAR WASH RANCHO CUCAMONGA 8172 VINEYARD AVE, RANCHO CUCAMONGA, CA 91730INCWaber Consultants PLANNING CIVIL ENGINEERING SURVEYING 3816 STINEMAN CT, SUITE 201, LONG BEACH, CA 90808 P (424) 344-2464 F (562) 372-3282 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 DIAL BEFORE YOU DIG TWO WORKING DAYS BEFORE YOU DIG REVISIONS DATE DESCRIPTION BENCHMARK VERTICAL DATUM WAS ESTABLISHED PER CITY OF RANCHO CUCAMONGA BENCHMARK 10025. FOUND 2" BRASS DISC IN CURB STAMPED "CITY OF RANCH CUCAMONGA BENCHMARK 10025 1987" AT THE NORTHWESTERLY CORNER OF 8TH AND VINEYARD AVE, WESTERLY END OF CURB BOX AT THE CURB RETURN, ELEVATION 1112.563". BASIS OF BEARINGS THE HORIZONTAL CONTROL WAS PER RECORD MONUMENTS ON RS 92 AND BOUNDARY SHOULD NOT BE USED FOR MAPPING PURPOSES. 0 SCALE: 1" = 20' 40'20'20'10' 1 PRELIMINARY GRADING AND DRAINAGE PLAN EARTHWORK: EXISTING GROUND TO FINISHED SURFACE COMPARISON: CUT 950 CY FILL 342 CY NET (CUT)608 CY PRELIMINARY GRADING AND DRAINAGE PLAN CAR WASH RANCHO CUCAMONGA 8172 VINEYARD AVE, RANCHO CUCAMONGA, CA 91730 VICINITY MAP SCALE 1" = 1000' LEGEND: PCC PAVEMENT PCC SIDEWALK STEM WALL PROPERTY LINE PROPOSED STORM DRAIN GRADE BREAK RIDGE LINE SD EASEMENT NOTES: INDICATES AN EASEMENT FOR ROAD PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 1981-103854, REC. 5-12-1981, O.R. INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPLY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2002-0673370, REC 12-11-2002, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR SIDEWALK PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 2003-0821215, REC 10-30-2003, O.R. INDICATES AN EASEMENT FOR SIDEWALK PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 2003-0821216, REC 10-30-2003, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2008-0266812, REC. 6-18-2008, O.R. INDICATES AN EASEMENT FOR DRAINAGE PURPOSES IN FAVOR OF FOOTHILL VINEYARD PLAZA, LLC, PER INST. NO. 2018-0468672, REC 12-20-2018, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR GAS PIPELINE PURPOSES IN FAVOR OF SOUTHERN CALIFORNIA GAS COMPANY, PER INST. NO. 2022-136434, REC 4-12-2022, O.R. INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2022-0333320, REC. 10-5-2022, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) 2 3 4 6 7 5 1 8 GB R VINEYARD AVE. VINEYARD AVE (20) (16) (17) (18) (19) (19) (1 9 ) (19) (19) (21) (22) (23 )(23) (23) (23) (2 3 ) (2 4 ) (15) (20) (13) (13) (14)(14) (14)(14) (14) (16) (1 7 ) (1 8 ) (19) (2 1 ) (21) (21) (1 5 ) (2 0 ) (20)(20) (2 0 ) (20) (14) (1 6 ) (17) (18) (19) (20) (19) (19) (19) (2 1 ) 7 5 1 3 5 5 DO NOT ENTER TE <<<<< VACUUM EQUIPMENT ROOM POLISH TUNNEL FF = 18.18 EQUIPMENT ROOM FF = 18.18 CARWASH TUNNEL FF = 17.68 DO NOT ENTER DO NOT ENTER < KIOSK FF = 17.65 R < < < <<<<< < < SD SD SD SD SD S S SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSS W W W W W W W W W W W W W W W W W W W W W W W W W W W W AREA - 1 TOTAL 45,192 SF PERVIOUS (LS) 14,525 SF IMPERVIOUS (HS) 30,667 SF PERFORATED CMP VREQUIRED: 1,740 CF VPROVIDED: 1,830 CF CDS UNIT LF = 356 OF 3 SHEETS SHEET DATE: JOB NO.25021 11/6/2025 W: \ 2 5 - 0 2 1 c a r w a s h r a n c h o c u c a m o n g a \ D W G \ 2 5 0 2 1 P 0 2 W Q M P . d w g N o v 0 6 , 2 0 2 5 - 1 1 : 2 2 a m CAR WASH RANCHO CUCAMONGA 8172 VINEYARD AVE, RANCHO CUCAMONGA, CA 91730INCWaber Consultants PLANNING CIVIL ENGINEERING SURVEYING 3816 STINEMAN CT, SUITE 201, LONG BEACH, CA 90808 P (424) 344-2464 F (562) 372-3282 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 DIAL BEFORE YOU DIG TWO WORKING DAYS BEFORE YOU DIG REVISIONS DATE DESCRIPTION BENCHMARK VERTICAL DATUM WAS ESTABLISHED PER CITY OF RANCHO CUCAMONGA BENCHMARK 10025. FOUND 2" BRASS DISC IN CURB STAMPED "CITY OF RANCH CUCAMONGA BENCHMARK 10025 1987" AT THE NORTHWESTERLY CORNER OF 8TH AND VINEYARD AVE, WESTERLY END OF CURB BOX AT THE CURB RETURN, ELEVATION 1112.563". BASIS OF BEARINGS THE HORIZONTAL CONTROL WAS PER RECORD MONUMENTS ON RS 92 AND BOUNDARY SHOULD NOT BE USED FOR MAPPING PURPOSES. 0 SCALE: 1" = 20' 40'20'20'10' 2 PRELIMINARY WQMP PRELIMINARY WQMP CAR WASH RANCHO CUCAMONGA 8172 VINEYARD AVE, RANCHO CUCAMONGA, CA 91730 LEGEND: LANDSCAPE AREA IMPERVIOUS AREA STRUCTURAL BMP DRAINAGE BOUNDARY STENCIL "NO DUMPING" SIGN FLOW PATH A < A A EASEMENT NOTES: INDICATES AN EASEMENT FOR ROAD PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 1981-103854, REC. 5-12-1981, O.R. INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPLY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2002-0673370, REC 12-11-2002, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR SIDEWALK PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 2003-0821215, REC 10-30-2003, O.R. INDICATES AN EASEMENT FOR SIDEWALK PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 2003-0821216, REC 10-30-2003, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2008-0266812, REC. 6-18-2008, O.R. INDICATES AN EASEMENT FOR DRAINAGE PURPOSES IN FAVOR OF FOOTHILL VINEYARD PLAZA, LLC, PER INST. NO. 2018-0468672, REC 12-20-2018, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR GAS PIPELINE PURPOSES IN FAVOR OF SOUTHERN CALIFORNIA GAS COMPANY, PER INST. NO. 2022-136434, REC 4-12-2022, O.R. INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2022-0333320, REC. 10-5-2022, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) 2 3 4 6 7 5 1 8 VINEYARD AVE. VINEYARD AVE (20) (16) (17) (18) (19) (19) (1 9 ) (19) (19) (21) (22) (23 )(23) (23) (23) (2 3 ) (2 4 ) (15) (20) (13) (13) (14)(14) (14)(14) (14) (16) (1 7 ) (1 8 ) (19) (2 1 ) (21) (21) (1 5 ) (2 0 ) (20)(20) (2 0 ) (20) (14) (1 6 ) (17) (18) (19) (20) (19) (19) (19) (2 1 ) 7 5 1 3 5 5 SD SD SD SD SD S S SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSS W W W W W W W W W W W W W W W W W W W W W W W W W W W W DO NOT ENTER TE <<<<< VACUUM EQUIPMENT ROOM POLISH TUNNEL FF = 18.18 EQUIPMENT ROOM FF = 18.18 CARWASH TUNNEL FF = 17.68 DO NOT ENTER DO NOT ENTER < KIOSK FF = 17.65 PERFORATED CMP VREQUIRED: 1,740 CF VPROVIDED: 1,830 CF CDS UNIT PROPOSED 6" SEWER LINE PER PROPOSED 2" DOMESTIC WATER LATERAL PROPOSED WATER METER PROPOSED BACKFLOW PREVENTER INSTALL 2" DOMESTIC WATER SERVICE INSTALL 6" FIRE SERVICE TIE-IN TO BUILDING TIE-IN TO EXISTING SEWER MAIN PROPOSED 6" FIRE LATERAL PROPOSED 1" IRRIGATION LATERAL PROPOSED BACKFLOW PREVENTER INSTALL 1" IRRIGATION WATER SERVICE PROPOSED CATCH BASIN PROPOSED CATCH BASIN PROPOSED CATCH BASIN PROPOSED CURB DRAIN OF 3 SHEETS SHEET DATE: JOB NO.25021 11/6/2025 W: \ 2 5 - 0 2 1 c a r w a s h r a n c h o c u c a m o n g a \ D W G \ 2 5 0 2 1 P 0 3 P U T . d w g N o v 0 6 , 2 0 2 5 - 1 1 : 2 2 a m CAR WASH RANCHO CUCAMONGA 8172 VINEYARD AVE, RANCHO CUCAMONGA, CA 91730INCWaber Consultants PLANNING CIVIL ENGINEERING SURVEYING 3816 STINEMAN CT, SUITE 201, LONG BEACH, CA 90808 P (424) 344-2464 F (562) 372-3282 A PUBLIC SERVICE BY UNDERGROUND SERVICE ALERT TOLL FREE 1-800-227-2600 DIAL BEFORE YOU DIG TWO WORKING DAYS BEFORE YOU DIG REVISIONS DATE DESCRIPTION BENCHMARK VERTICAL DATUM WAS ESTABLISHED PER CITY OF RANCHO CUCAMONGA BENCHMARK 10025. FOUND 2" BRASS DISC IN CURB STAMPED "CITY OF RANCH CUCAMONGA BENCHMARK 10025 1987" AT THE NORTHWESTERLY CORNER OF 8TH AND VINEYARD AVE, WESTERLY END OF CURB BOX AT THE CURB RETURN, ELEVATION 1112.563". BASIS OF BEARINGS THE HORIZONTAL CONTROL WAS PER RECORD MONUMENTS ON RS 92 AND BOUNDARY SHOULD NOT BE USED FOR MAPPING PURPOSES. 0 SCALE: 1" = 20' 40'20'20'10' 3 PRELIMINARY UTILITY PLAN PRELIMINARY UTILITY PLAN CAR WASH RANCHO CUCAMONGA 8172 VINEYARD AVE, RANCHO CUCAMONGA, CA 91730 <<< ABBREVIATIONS: AC ASPHALT CONCRETE CF CURB FACE EX. EXISTING FF FINISHED FLOOR FL FLOW LINE GB GRADE BREAK MAX. MAXIMUM MIN. MINIMUM P/L PROPERTY LINE PCC PORTLAND CEMENT CONCRETE RL RIDGE LINE R/W RIGHT OF WAY SD STORM DRAIN TE TRASH ENCLOSURE LEGEND: R/W OR P/L EASEMENT LINE CURB CURB AND GUTTER FLOW LINE STORM DRAIN LINE WATER LINE SANITARY SEWER LINE SD W S EASEMENT NOTES: INDICATES AN EASEMENT FOR ROAD PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 1981-103854, REC. 5-12-1981, O.R. INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPLY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2002-0673370, REC 12-11-2002, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR SIDEWALK PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 2003-0821215, REC 10-30-2003, O.R. INDICATES AN EASEMENT FOR SIDEWALK PURPOSES IN FAVOR OF THE CITY OF RANCHO CUCAMONGA PER INST. NO. 2003-0821216, REC 10-30-2003, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2008-0266812, REC. 6-18-2008, O.R. INDICATES AN EASEMENT FOR DRAINAGE PURPOSES IN FAVOR OF FOOTHILL VINEYARD PLAZA, LLC, PER INST. NO. 2018-0468672, REC 12-20-2018, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) INDICATES AN EASEMENT FOR GAS PIPELINE PURPOSES IN FAVOR OF SOUTHERN CALIFORNIA GAS COMPANY, PER INST. NO. 2022-136434, REC 4-12-2022, O.R. INDICATES AN EASEMENT FOR UNDERGROUND ELECTRICAL SUPPY SYSTEMS AND COMMUNICATION SYSTEMS IN FAVOR OF SOUTHERN CALIFORNIA EDISON CO. PER INST. NO. 2022-0333320, REC. 10-5-2022, O.R. (NOT APPLICABLE TO SUBJECT PROPERTY) 2 3 4 6 7 5 1 8 CODE BOTANICAL NAME COMMON NAME SIZE WUCOLS QTY TREES AB Acacia baileyana Bailey Acacia 36" Box Low 12 AS Acacia stenophylla Shoestring Acacia 36" Box Low 7 CB Cordia boissieri Anacahuita 24"box Low 8 LP Leptospermum petersonii Lemon-scented Tea Tree 24"box Low 12 QE Quercus engelmannii Engelmann Oak 36" Box Very Low 4 RS Rhus lancea African Sumac 36" Box Low 12 TF Trachycarpus fortunei Windmill Palm 10` Clear Trunk Height Low 15 SHRUBS A Agave attenuata 'Nova'Nova Foxtail Agave 5 gal Low 108 H Anigozanthos x 'Harmony'Harmony Yellow Kangaroo Paw 5 gal Low 64 B Berberis aquifolium Oregon Grape 5 gal Low 175 S Strelitzia juncea Narrow-leafed Bird of Paradise 5 gal Low 96 VINE/ESPALIER Al Antigonon leptopus Coral Vine 5 gal Low 7 M Macfadyena unguis-cati Cat's Claw Creeper 5 gal Low 20 SYMBOL BOTANICAL NAME COMMON NAME SIZE WUCOLS SPACING QTY GROUND COVERS Cistus crispatus 'Warley Rose'Warley Rose Rockrose 5 gal Low 36" o.c.622 sf Dianella revoluta 'Little Rev'Little Rev Spreading Flax Lily 1 gal Low 30" o.c.2,186 sf Hesperaloe parviflora Red Yucca 5 gal Low 48" o.c.1,176 sf Lantana x 'New Gold'New Gold Lantana 1 gal Low 30" o.c.830 sf Mimulus x 'Jelly Bean Gold'Jelly Bean Gold Monkeyflower 1 gal Low 18" o.c.1,370 sf PLANT SCHEDULE SITE DO NOT ENTER ESCA P E LANE DO NOT ENTER DO NOT ENTER PROPERTY LINE PROPERTY LINE FENCE WALL S00°00'00"E 272.66' S8 9 ° 5 2 ' 3 0 " E 81 . 8 7 ' S8 9 ° 5 2 ' 3 0 " E 96 . 0 0 ' S8 9 ° 5 2 ' 3 0 " E 14 . 0 0 ' N00°13'40"E 474.47' N00°13'40"E 90.00' N00°13'40"E 90.00' EXISTING WATER VALVE EXISTING SEWER MANHOLE EXISTING WATER METER EXISTING WATER VALVE EXISTING SEWER MANHOLE CONNECT TO SEWAGE DISPOSAL ℄ EXISTING DRIVEWAY -- PL-1 PR E L I M I N A R Y LA N D S C A P E P L A N Issue ofSheet # NN THIS IS A COPYRIGHTED DOCUMENT AND MAY NOT BE REPRODUCED IN PART OR WHOLE WITHOUT WRITTEN PERMISSION OF ARCADIA STUDIO INC. COPYRIGHT 2011. Date Revisions Drawn By Job Number Checked by Issue 202 East Cota Street Santa Barbara, CA 93101 tel 805.962.9055 fax 805.962.5658 arcadiastudio.com Dr a w i n g N a m e : Z: \ S h a r e d \ P r o j e c t s \ 2 0 2 5 P r o j e c t s \ 2 5 . 0 4 7 A & S C u c a m o n g a \ 2 5 . 0 4 7 C a d \ 2 5 . 0 4 7 I n P r o g r e s s \ A & S R a n c h o C u c a m o n g a \ s h e e t s \ P r e l i m i n a r y L a n d s c a p e P l a n \ P L - 1 P r e l i m i n a r y L a n d s c a p e P l a n . d w g P l o t d a t e : 20 2 5 - 1 0 - 3 1 5 : 5 1 P M 25.047 MG BC 10/28/2025 VI N E Y A R D C A R W A S H 87 1 2 V i n e y a r d A v e . Ra n c h o C u c a m o n g a , C A 91 7 3 0 No. 3513 EXP. 10.31.26 0 16 328 Scale: 1/16" = 1'-0" Trachycarpus fortunei / Windmill Palm Plans will comply with all the criteria in MWELO and apply them for the efficient use of water in the landscape design plan. Irrigation system will use drip irrigation and a smart weather based controller that will automatically adjust the watering schedule based on local weather conditions. Acacia baileyana / Bailey Acacia For inquiries regarding this plan contact Bob Cunningham ASLA (805) 962-9055 bc@arcadiastudio.com CONS T R U C T I O N NOT F O R Shrubs and Perennials Dianella revoluta 'Baby Bliss' / Baby Bliss Flax Lily Strelitzia juncea / Narrow-leafed Bird of Paradise Berberis aquifolium / Oregon Grape Hesperaloe parviflora / Red Yucca Quercus engelmannii / Engelmann Oak Acacia baileyana / Bailey Acacia Acacia stenophylla / Shoestring Acacia Leptospermum petersonii / Lemon-scented Tea Tree Rhus lancea / African Sumac Trachycarpus fortunei / Windmill Palm Agave attenuata 'Nova' / Nova Foxtail Agave Anigozanthos x 'Harmony' / Harmony Yellow Kangaroo Paw Antigonon leptopus / Coral Vine Cistus crispatus 'Warley Rose' / Warley Rose Rockrose Lantana x 'New Gold' / New Gold Lantana Mimulus x 'Jelly Bean Gold' / Jelly Bean Gold Monkeyflower CONCEPTUAL PLANT PALETTE Trees Acacia stenophylla / Shoestring Acacia Quercus engelmannii / Engelmann Oak Leptospermum petersonii / Lemon-scented Tea Tree Cistus crispatus 'Warley Rose' / Warley Rose Rockrose Agave attenuata 'Nova' / Nova Foxtail Agave Anigozanthos x 'Harmony' / Harmony Yellow Kangaroo Paw Antigonon leptopus / Coral Vine Strelitzia juncea / Narrow-leafed Bird of Paradise Berberis aquifolium 'Compacta' / Compact Oregon Grape Dianella revoluta 'Little Rev' / Little Rev Flax Lily Hesperaloe parviflora / Red Yucca Mimulus x 'Jelly Bean Gold' / Jelly Bean Gold Monkeyflower Lantana x 'New Gold' / New Gold Lantana Cordia boissieri / Anacahuita Cordia boissieri / Anacahuita Rhus lancea / African Sumac Macfadyena unguis-cati / Cat's Claw Creeper Macfadyena unguis-cati / Cat's Claw Creeper