Loading...
HomeMy WebLinkAbout1603STREET IMPROVIE MENT GENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE CITY OF RANCHO CUCAMONGA STANDARDS AND THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION - CURRENT EDITION, INCLUDING ITS ANNUAL SUPPLEMENTS OF AMENDMENTS. CONTRACTOR SHALL BE FAMILIAR WITH AND SHALL BE RESPONSIBLE FOR ADHERENCE TO THESE STANDARDS AND SPECIFICATIONS, 2. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND, TELEPHONE OR POWER POLES, WATER METERS, VALVES, FIRE HYDRANTS, ETC, SHOWN OR NOT SHOWN ON THESE PLANS WITHIN THE RIGHT-OF-WAY LIMITS OR IN ADJACENT AREAS WHERE IMPROVEMENT WORK IS TO BE: DONE SHALL BE REMOVED, REPLACED, RELOCATED OR PROTECTED IN PLACE AS REQUIRED AT NO COST TO THE CITY OF RANCHO CUCAMONGA. 3. ANY CONTRACTOR PERFORMING WORK ON THIS PROJECT SHALL FAMILIAR ZE HIMSELF WITH THE SITE AND SHALL BE SOLELY RESPONSIBLE FOR ANY DAMAGE TO EXISTING FACILITIES RESULTING DIRECTLY OR INDIRECTLY FROM HIS OPERATIONS, WHETHER OR NOT SUCH FACILITIES ARE SHOWN ON THESE PLANS. 4. A PERMIT SHALL BE OBTAINED FROM THE CITY OF RANCHO CUCAMONGA PUBLIC WORKS, ENGINEERING DEPARTMENT PRIOR TO ANY ENCROACHMENT OR CONSTRUCTION WITHIN ANY CITY OF RANCHO CUCAMONGA EASEMENT OR RIGHT-OF-WAY, 5. ALL GRADE STAKES SHALL BE SET BY THE CONTRACTOR OR ENGINEER. PAVING STAKES SHALL BE SET AT ALL HINGE POINTS, EDGE OF PAVEMENT POINTS WITHIN 0.01 FOOT OF SUB --GRADE ELEVATION AND AT NOT MORE THAN 50 FOOT INTERVALS. ADDITIONAL PAVING STAKES MAY BE REQUIRED BY CITY ENGINEER AS NEEDED AT WARPED OR VERTICAL CURVE AREAS. 6. ALL SEWER, WATER, ELECTRIC, GAS, PHONE OR OTHER UTILITY LATERALS, MAINS, OR CROSSINGS SHALL BE CONSTRUCTED PRIOR TO PAVING. 7. COMPACTION TESTS OF EMBANKMENT CONSTRUCTION, TRENCH BACKFILL, COMPACTING ORIGINAL GROUND AND ALL SUB -GRADES SHALL BE PERFORMED AT NO COST TO THE CITY OF RANCHO CUCAMONGA. A WRITTEN REPORT WITH THESE COMPACTION TESTS SHALL BE SUBMITTED TO THE: CITY ENGINEER FOR APPROVAL PRIOR TO THE PLACEMENT OF BASE MATERIALS AND/OR SURFACING. 8. AT THE COMPLETION OF PAVING, A MATERIALS REPORT SHALL BE SUBMITTED TO THE: CITY ENGINEER LISTING ALL TESTS OR DETERMINATIONS COMPLETED TO VERIFY STAE3ILITY OIL CONTENT AND GRADATION OF ASPHALT PAVING. 9. PRIOR TO INSTALLATION OF ANY PAVING, A MATERIALS REPORT SHALL BE SUBMITTED TO THE CITY ENGINEER, LISTING ALL TESTS OR DETERMINATIONS COMPLETED TO VERIFY: R -VALUE, SIEVE ANALYSIS AND SAND EQUIVALENT, TO DETERMINE THE FINAL STRUCTURAL SECTION OF ASPHALT AND AGGREGATE BASE. 10. PAVING SHALL BE PERFORMED IN ACCORDANCE WITH R --VALUE AND PAVEMENT TESTS TAKEN TO DETERMINE STRUCTURAL SECTIONS, PRIOR TO CONSTRUCTION OF THE STRUCTURAL SECTION, 11. WHEN IMPROVEMENTS ARE TO BE PLACED ON NATIVE SOIL WHICH CONSISTS OF A ROCKY MATERIAL, THE SUB -GRADE SHALL BE PREPARED BY REMOVING ALL ROCKS WHICH PROTRUDE ABOVE THE SUB -GRADE AND ALL VOIDS OR DEPRESSIONS SHALL BE FILLED WITH A FINE GRADE MATERIAL OF A QUALITY BETTER THAN THE NATIVE MATERIAL. 12. ESTIMATE OF QUANTITIES IS PROVIDED BY THE ENGINEER ONLY FOR THE CONVENIENCE OF THE DEVELOPER, THE CONTRACTOR SHALL MAKE HIS OWN DETERMINATION OF CONSTRUCTION QUANTITIES BEFORE SUBMITTING A BID. ANY ITEM OF WORK REQUIRED BY THESE PLANS WHICH IS NOT SPECIFICALLY LISTED IN THE ESTIMATE OF' QUANTITIES SHALL BE CONSIDERED AS INCLUDED IN THE OTHER ITEMS OF WORK. 13. STREET SIGNS PER CITY OF RANCH CUCAMONGA STANDARD NUMBER 401 SHALL BE CONSTRUCTED AT EACH INTERSECTION. 14. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE CORRECTION OF ERROR AND OMISSION DISCOVERED DURING CONSTRUCTION. UPON REQUEST, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL. 15. WORK SITE AND EXTERIOR STREETS SHALL BE IN A NEAT, CLEAN, HAZARD FREE, ORDERLY STATE, THROUGHOUT CONSTRUCTION. SITE SHALL BE CLEANED UPON REQUEST OF THE INSPECTOR. 16. CONTACT ALL UTILITY COMPANIES AS REQUIRED, 48 HOURS PRIOR TO EXCAVATION. GENERAL TELEPHONE (800) 483-3000 SOUTHERN CALIFORNIA GAS COMPANY (800) 427-2200 (RES.) 216 N. EUCLID AVENUE (800) 427--2000 (COMM.) ONTARIO, CA 91762. CUCAMONGA COUNTY WATER DISTRICT (909) 987-2591 9641 SAN BERNARDINO ROAD RANCHO CUCAMONGA, CA 91730 METROPOLITAN WATER DISTRICT (909) 593-7474 700 N. MORENO AVENUE LA VERNE, CA 91750 COMCAST (909) 983-9895 1205 DUPONT ST. (PORTION OF RED HILL) ONTARIO, CA 91762 MARKS CABLEVISION (909) 880-022.0 10808 FOOTHILL BLVD. #120 RANCHO CUCAMONGA, CA 91730 Underground Service Alert �51 Y CO TOLL. FREE X800 422-4133 NO WORKM DAYS BEFORE YOU N CITY QF RANCHO CUCAMONGA BRAG I I�10. 15726 STREET IMPROVEMENT PLANS CONSTRUCTION NOTES FOR STREET TREES: 1. ALL STREET TREES SHALL BE PLANTED AND STAKED ACCORDING TO CITY STANDARDS AND SPECIFICATIONS, AS PROXIMITY TO HARDSCAPE DICTATES. NO STREET TREE_ SHALL BE PLANTED WHERE THE CENTER OF THE TRUNK IS CLOSER THAN THREE FEET (3') TO THE FACE OF CURB, EDGE OF SIDEWALK OR FACE OF WALL, UNLESS OTHERWISE NOTED. 2. PRIOR TO THE COMMENCEMENT OF ANY PLANTING, AN AGRONOMIC SUITABILITY/FERTILITY SOILS REPORT SHALL BE FURNISHED TO THE CITY INSPECTOR. ANY UNUSAUL TOXICITIES OR NUTRIENT DEFICIENCIES MAY REQUIRE BACKFILL_ SOIL AMENDMENTS, AS DETERMINED BY THE CITY INSPECTOR. 3. ALL STREET TREES ARE SUBJECT TO INSPECTION AND ACCEPTANCE BY THE ENGINEERING DIVISION. 4. STREET TREES ARE TO BE PLANTED PER PUBLIC IMPROVEMENT PLANS ONLY. 5. ROOT CONTROL BARRIERS ARE NOT REQUIRED UNLESS OTHERWISE NOTED. SYMBOL STREET NAME BOTANICAL/COMMON NAME QTY. SPACING SIZE 4- PHILLIPS WAY MAGNOLIA GRANDIFLORA 'ST MARY15 22 20 o.c. GAL. 4- BRISTOL DRIVE GINKO BILOBA 'FAIRMOUNT' 5 35'o.c. 15 SIDEWALK L MAIDENHAIR TREE SIDEWALK 402 GAL. -+- ORANGE PISTACIA CHINE:NSIS 'KEITH DAVEY' 5 30'o.c. 15 233 L. F. GUTTER STA. 18+05.00 TO STA. 19+33.00) 85 GAL. * l M 0 N AVENUE_ LEMON AVE. LAGERSTROEMIA / FAURIEI 'BILOXI' 3 20 o.c. 15 1,470 L. F. PINK HYBRID CRAPE MYRTLE HEREOF. 6,481 GAL. [r 66' 33' 1 1 ' 1 22' 22' H.U. rNVLMLIV I EXIST. AC +i-12' PAVE M EN T 6.5' 4' 0.5' 2% 92 30' 1 30' _ I 12' 18' _ I _ 18' 12' cr 0.5' 4' 7.5 7.5' 4' 0.5' A.C. PAVEMENT � �PCC . �� �� PCC �--������>�� �� SIDEWALK SIDEWALK ZPCC CURB & PCC CURB & GUTTER GUTTER PHILLIPS WAY ORANGE STREET BRISTOL STREET TYPICAL STREET SECTIONS HORIZ: 1 "= 10' VERT: 1 "= 2' NOTE REFERENCE DRAWINGS LEMON AVENUE STA. 11+50 TO STA. 19+75 SHT. 5 OF 11 DWG NO. 1050 BRISTOL DR. TR. 9302 SHT. 3 OF 4 DWG NO. 607 ORANGE ST. SHT. 4- OF 4 DWG NO. 607 2' 0 R 5' SEE PLAN 0.10' MIN. NEW AC EXIST. AC - -0.10' MIN. COLD PLAN DETAIL N.T.S. BANYON LEMON V) V) 19TH I BASELINE z Q Lu z cr a U J w ST. AVE. Q a Q HIGH AND r^� ST. w Q ROAD AVE. Q P'ROJEC'T LOCATION' Q co o w TERRA � a T_ �SZ A w cr w z CHURCH ST. ST FOOTHILL BLVD. 66 VICINITY MAP PAD PER EXIST. �'`- - SCALE: 1" = 2640' -PCC PLAN SIDEWALK L �1 -- SIDEWALK 402 EXIST. L (5' WIDE SIDEWALK ALONG WALL_ 30,046 CURB & GUTTER PCC CURB & LOCATIONS WITH NO 0.5' OFFSET 233 L. F. GUTTER STA. 18+05.00 TO STA. 19+33.00) 85 L. F. * l M 0 N AVENUE_ * SEE ATTACHED CROSS -SE BY -E THIS EFERENCE MADE PTARTS 1,470 L. F. HEREOF. 6,481 TYPICAL STREET SECTIONS (5' ADJACENT TO WALLS) HORI.Z: 1 "= 10' CONSTRUCT HANDICAP ACCESS RAMP PER CITY STD DWG. 102 2 VERT: 1 "= 2' O-- 92 30' 1 30' _ I 12' 18' _ I _ 18' 12' cr 0.5' 4' 7.5 7.5' 4' 0.5' A.C. PAVEMENT � �PCC . �� �� PCC �--������>�� �� SIDEWALK SIDEWALK ZPCC CURB & PCC CURB & GUTTER GUTTER PHILLIPS WAY ORANGE STREET BRISTOL STREET TYPICAL STREET SECTIONS HORIZ: 1 "= 10' VERT: 1 "= 2' NOTE REFERENCE DRAWINGS LEMON AVENUE STA. 11+50 TO STA. 19+75 SHT. 5 OF 11 DWG NO. 1050 BRISTOL DR. TR. 9302 SHT. 3 OF 4 DWG NO. 607 ORANGE ST. SHT. 4- OF 4 DWG NO. 607 2' 0 R 5' SEE PLAN 0.10' MIN. NEW AC EXIST. AC - -0.10' MIN. COLD PLAN DETAIL N.T.S. BANYON LEMON V) V) 19TH I BASELINE z Q Lu z cr a U J w ST. AVE. Q a Q HIGH AND r^� ST. w Q ROAD AVE. Q P'ROJEC'T LOCATION' Q co o w TERRA � a T_ �SZ A w cr w z CHURCH ST. ST Q pFE:SS�O& 1 No. 36052 EXP, E/30/2000 CIV ATF OF C ILL NU. Filenome: L\DWG\11102\15726ST1.DWG Date: FE B.4, 1998 FOOTHILL BLVD. 66 VICINITY MAP SCALE: 1" = 2640' CONSTRUCTION NOTES QUANTITIES �1 -- REMOVE EXIST. HEADER 402 L. F. 2a- CONSTRUCT 4" A.C. PAVEMENT OVER 4" C.A.B. PER CITY STD 100--A 30,046 S.F. 3a-- CONSTRUCT 8" PCC CURB & GUTTER PER CITY STD DWG. 104, TYPE A2-8 233 L. F. CONSTRUCT VARIABLE HEIGHT PCC CURB & GUTTER PER CITY STD DWG. 104, 85 L. F. TYPE A2-8, 8 TO 6"CURB FACE 5�-- CONSTRUCT 6" PCC CURB & GUTTER PER CITY STD DWG. 104, TYPE A2-6 1,470 L. F. CONSTRUCT PROPERTY LINE SIDEWALK PER CITY STD DWG. 103, W=4' 6,481 S.F. (5' ADJACENT TO WALLS) CONSTRUCT HANDICAP ACCESS RAMP PER CITY STD DWG. 102 2 EA O-- CONSTRUCT PCC CROSS -GUTTER & SPANDREL PER CITY STD DWG., 106-A 764 S.F. CONSTRUCT DRIVE APPROACH PER CITY STD. DWG. 101 -A 5,003 S.F. 10 ADJUST SEWER MANHOLE FRAME AND COVER TO GRADE PER CITY STD. 323-B _ 6 EA 11 - INSTALL STREET NAME SIGN AND POST PER CITY STD DWG. 401 3 EA 12 REMOVE EXIST. BARRICADE AND EXIST. W53 SIGN 2 EA 13 COLD PLANE EXISTING A.C. PAVEMENT 0.10' MIN AND REPLACE A.C. PAVEMENT FOR A SMOOTH JOIN. 1,020 S.F. 14 - INSTALL STREET TREES PER NOTES AND LEGEND HEREON, AND PER CITY" STD. PLAN NO. 501 15 - INSTALL 5800 LUMEN HPSV STREET LIGHTS BY S.C.E. PAID AND COORDINATED BY DEVELOPER. 7 EA 16 - INSTALL R1 (STOP) SIGN (36") PAINT 12" SOLID WHITE LIMIT LINE AND PAINT "STOP" LEGEND 2 EA 17 - REPAINT f=XIST. 4" YELLOW LINE PER CITY STD. NO. 133 427 L. F. 18 - PAINT 4" SOLID WHITE TRAFFIC LINE 36 L. F. 19 - GRADE TO MATCH SIDEWALK AS NEEDED 20 - CONSTRUCT CURBSIDE DRAIN OUTLET PER CITY STD. DWG. 107-B 1 EA. Q pFE:SS�O& 1 No. 36052 EXP, E/30/2000 CIV ATF OF C ILL NU. Filenome: L\DWG\11102\15726ST1.DWG Date: FE B.4, 1998 LEMON - - - EXIST CURB ~l __ 16+16-.44 - EX1ST_ FELLOW 13ROXEN TRAFFlC -'1 �' .48 C l do GUTTER 4+87. -G -1 TRACT BDRY STRIPPING -OR -tCt---------�-..�__ _ _ 17 -tQa'�BROKEN X�"w TRAFFIC UNE 7a0' ^SOLID YELLUW 'TRAFi EXISTING EP FUTURE Cac G a C ONSTRUCTM NOTES EXIST. SO11 LID -WHITE T 4A - _FF IC LINE- AT E.P. t�- REMOVE EXIST. HEADER ( m Q 3 15 CONSTRUCT 4" A.C. PAVEMENT OVER 4" C.A.B. PER CITY STD 100-A 3a— CONSTRUCT 8" PCC CURB & GUTTER PER CITY STD DWG. 104, TYPE A2-8 4a--- CONSTRUCT VARIABLE HEIGHT PCC CURB & GUTTER PER CITY STD DWG. 104, TYPE A2-8, 8" TO 6" CURB FACE CONSTRUCT PROPERTY LINE SIDEWALK PER CITY STD DWG. 103, W=4' (5' ADJACENT TO WALLS) CONSTRUCT HANDICAP ACCESS RAMP PER CITY STD DWG. 102 a-- CONSTRUCT PCC CROSS -GUTTER & SPANDREL PER CITY STD DWG. 106-A 1 t INSTALL STREET NAME SIGN AND POST PER CITY STD DWG. 401 13 COLD PLANE EXISTING ACE PAVEMENT 0.10' MIN AND REPLACE AC PAVEMENT FOR A SMOOTH JOIN t4 INSTALL STREET TREE PER NOTES AND LEGEND ON SHEET 1, AND PER CITY STD. PLAN NO. 501 i5 INSTALL 5800 LUMEN HPSV STREET LIGHTS BY S.C.E. PAID AND COORDINATED BY DEVELOPER 16 INSTALL R1 (STOP) SIGN (36") PAINT 12' SOLID WHITE LIMIT LINE & PAINT "STOP" LEGEND 5—REPAINT EXIST. 4" YELLOW LINE PER CITY STD. NO.133 8—PAINT 4" SOLID WHITE TRAFFIC LINE 8—GRADE TO MATCH SIDEWALK AS NEEDED .- EXIST CURB" \ RUN - - & GUTTER SWD YELLOW TRAFM-L+I_ ON' CL "+00 CURVE RADIUS LENGTH TANGENT DELTA 42.45 4 B 27.00 42.38 1 26.97 89-55-35' NOTE: STREET TREES ON LEMON AVENUE FOR BACK -ON LOTS 16 AND 17 SEE THE LMD PLANS FOR THE TRACT. EN YELLOW TRAFFIC LINE 17 EXIST. CURB & GUTTER FESS/ ESS / pN 052 z m Exp 2D00 %p�9TF OF- CA1-�F SCALE: 1 " = 20' I DESCRIPTION OF REVISION I DATE I CITY I APPROVED CITY OF RANCHO CUCAMONGA APPROVED BY: CITY ENGINEER DESIGN SCN DRAWN SCN CHECKED RJA PLAN and PROFILE FOR STREET WROVEMENM LEMON AVENUE STA. 16+10.44 to STA. 19+33.44 TRACT NO. 15726 DATE: RCE NO. 24953 ALLARD ENMEE'RrMG RECOMMENDED Civil Engineering - Land Planning 6101 Cherry Avenue SHEET Fontana, California 92336 (909) 899-5011 Fax (909) 899-5014 2 4 R.C.E. NO. 36052 DRAWING NO. DATE FILE N0. _I 11.02.02 1603 Filename: L:\DWG\11102\15726ST2.DWG Date: FE8.4, 1998 1�i� iii ='�e � �: 00111mmem ■����- i : s ME :n �i Mi mmmll � : ■� .ate-_- � �� ■ Mill . ■ ■ oo �■ �■ 9 10 - _ Hi -t tfF._ - - - - - - - - -tfiffl - - - = ffli _.- - - � HORIZ. 1 20 -- - - �U 15, r+ll 25 . ►� TRANSITION awn BRISTOL DRIVE SEE SHEET 4 2�--- CONSTRUCT 4" A.C. PAVEMENT OVER 4" C.A.B. PER CITY STD 100—A CONSTRUCT 6" PCC CURB do GUTTER PER CITY STD DWG. 104, TYPE A2-6 CONSTRUCT PROPERTY LINE SIDEWALK PER CITY STD DWG. 103, W=4' CONSTRUCT DRIVE APPROACH PER CITY STD. DWG. 101—A ? 0 ADJUST SEWER MANHOLE FRAME AND COVER TO GRADE PER CITY STD. 323—B 1 i INSTALL STREET NAME SIGN AND POST PER CITY STD DWG. 401 14 INSTALL STREET TREE PER NOTES AND LEGEND ON SHEET 1, AND PER CITY STD. PLAN NO. 501 &_INSTALL 5800 LUMEN HPSV STREET LIGHTS BY S.C.E. PAID AND COORDINATED BY DEVELOPER PHILLIPS Y JCG J"F_r_ 1 L gRgf ESS I pN �O �p J. q ql ` ) 9�a z JNo. 3-1052 rn Exp. 6 2000 OF LEMON STREET SEE SHEET 2 DESCRIPTION OF REVISIONI DATE I CITY I APPROVED CITY OF RANCHO CUCAMONGA APPROVED BY: CITY ENGINEEF DESIGN SCN DRAWN SCN CHECKED RJA PLAN and PROFILE FOR ST ET= T RfnOVEAAEM PHILLIPS WAY STA. 20+00.00 to STA. 24+87.07 TRACT NO.15726 I' DATE: RCE N0. 24953 ALLARD EffCmWERIIVIG RECO7MM DED Civil Engineering — Land Planning 6101 Cherry Avenue SHEET Fontana, California 92336 (909) 899-5011 Fax (909) 899-5014 3 OF__A_ R.C.E. NO. 36052 DRAWING NO. DATE FILE N0. 111.02.02 1603 Filename: L:\DWG\11102\15726ST3.DWG DATE: FE8.4, 1998 J, 13 W 1110; ■oA no] am 1601901 M I bi R" 11 A 'm= Bwl 1580 1580 + + + + + 1575 + + + -+- + -50 -25 0 15+75 25 50 C.L. R/W 1580 + + 22 +1 + 12't 1575 + _ + 1570 4- + A- V 16+75 1580 + + + + + -�-`---_ 1580 + + 1575 + + + + + 50 -25 0 25 50 1575 + 15+50 1570 + + 1580 + + + + + 1575 + + + -+- + -50 -25 0 25 50 15+25 1580 + + -+- + + 1575 .+ -+ + + + -50 -25 0 25 50 15+00 1580 + + + + + 1575 + + + + + -50 -25 0 25 50 14+75 1580 1575 1570 -50 -25 0 L .J C. L. R/W 22' 11 ' 12't �G i .vv soM 16+50 C.L. R/W J V `) V 1580 1575 1570 16+25 1 25 50 -50 -25 0 16+00 25 50 1575 1570 -50 -25 0 17+75 C.L. 1575 1570 1575 1570 -50 -25 0 C.L. 25 50 -50 -25 0 17+50 C.L. 25 50 1575 1570 -50 -25 0 17+00 25 50 17+25 C. L. R/W 25 50 1575 1570 -50 -25 0 17+88.48 C.L. 25 50 Filename: L:\DWG\11102\15726CG1.I DATE: JANUARY 15. 1997 .4!F 1575 1570 1575 1570 -50 -25 0 18+50 C.L. R/W -50 -25 0 18+75 C.L. 25 R/W 50 25 C.L. R/W 22' 1 1 1575 + + + 1570 + -50 -25 0 25 50 18+25 C.L. 50 1575 1570 -50 -25 0 18+00 25 50 1575 + + + + + 1570- + - --' + �+ + -50 -25 0 19+75 25 50 1575 + + + + 1570 + + + + -50 -25 0 25 19+50 C.L. R/W 1575 1570 -50 -25 0 50 1575 1570 -50 -25 0 25 19+25 C.L. R/W 50 19+00 25 50 1575 1570 1565 1575 1570 1565 -50 -25 0 20+75 25 50 -50 -25 1575 + 1570 + 1575 + 1570 + 0 20+50 25 50 + + + + 0 25 20+25 + + + -50 -25 0 25 20+00 50 + + 50 w Filename: L:\DWG\11102\15726CG1.0 DATE: JANUARY 15, 1997