HomeMy WebLinkAbout1711-S PLAN ACCURATE FOR ELECTRICAL HORK ONLY GENERAL NOTES GENERAL NOTES (CONT)
I. TRAFFIC SIGNAL AND HIGHWAY SAFETY LIGHTING 5Y5TEM5 PER GALTRAN5 STANDARD 6. LOOP DETECTORS SHALL BE 1.8m BY 1.8m, EXCEPT AS NOTED. CENTER LOOPS IN THE
PLANS DATED JULY Iggl AND STANDARD 5PECIFICATIONS DATED JULY Igg5, AS SHOWN ON THE TRAVELED PORTION OF THE LANE, EXCEPT AS 5HOWN.
PLANS AND IN THE SPECIAL PROVISIONS.
7. VEHICLE INDICATIONS SHALL BE 300mm, PULLBOXE5 No. 5 AND CONDUIT 51ZE 53 RIGID METAL
2. TRAFFIC 51GNS, STRIPES, MARKINGS AND LEOEN05 PER CALTRAN5 TRAFFIC SIGN SPEC- EXCEPT AS SHOWN.
FICATION5, TRAFFIC MANUAL, MAINTENANGE MANUAL, AND STANDARD 5PECIFIGATION5. CONFORM
PAVEMENT LEGEND5 TO CITY 5TENGIL5. REFLEGTORIZE ALL 51GN5, 5TRIPE5 AND LEGENDS.
8. THE CONDUCTOR SHEDULE I FURNISHED AS AN INSTALLATION GUIDE INE ONLY. IT SHALL
3. MARKERS AND PAINTING PROCEDURES FOR STRIPINPER STANDARD SPECIFICATIONS FOR BE THE CONTRAGTOR'5 RESPONSIBILITY TO PROVIDE THE GORREGT GONDUGTOR5
G
REQUIRED FOR THE INTENDED OPERATION. IN ADDITION TO CONDUCTORS GALLED FOR
PUBLIC HORK5 CONSTRUCTION, Igg7 EDITION WITH IggB AND IgGq 5UPPLEMENT5. IN CONDUCTOR SCHEDULE, INSTALL 1-#8 AWG BARE GROUNDING GONDUGTOR IN
4. LOCATE ALL 5UBSIGNAL GONDUIT5, EXCEPT INSTALL 1-#10 AWG BARE GROUNDING GONDUGTOR IN
5TRUGTURES PRIOR TO CONSTRUCTION. HAND DIG FOUNDATIONS UNTIL CONDUITS CONTAINING LOOP DETECTOR AND/OR INTERCONNECT GABLE ONLY.
CLEAR OF OB5TRUGTION5. COORDINATE POLE IN5TALLATION5 WITH OVERHEAD UTILITY OR
5UB5TRUGTURE OWNERS. PHONE UNDERGROUND 5ERVI6E ALERT AND CONCERNED UTILITY
VICINITNr M �' T I D X COMPANIES, 48 HOURS PRIOR TO CONSTRUCTION. LOCATION OF UTILITIES AND 5013- UTILITY COMPANIES PHONE NUMBERS
5TRUGTURE5 HAVE 13EEN 5+40M FROM A 5EARGH OF AVAILABLE RECORDS. THE GONTRAGTOR
SHALL CONDUCT HI5 OPERATION IN SUCH A MANNER AS TO PROTECT NOT ONLY THE SOUTHERN CALIFORNIA EDISON CO.
UTILITIES AND 5UB5TRUGTURE5 5HOWN, BUT OTHER UTILITIES OR 5UB5TRUGTURE5 THAT (CONTACT ) (qOq) q4-1-8227
Q _ _ _ _ _ _ �t1 _ _ _ _ Q ARE NOT SHOWN ON THESE PLAN5. SOUTHERN CALIFORNIA OAS GO. (800) 422-4133
PROPOSED FOOTHILL FKY 1 . Title Sheet GENERAL TELEPHONE CO. (800) 422-4133
5. OBTAIN APPROVAL FOR EXACT EQUIPMENT, CROSSWALK AND LIMIT LINE LOCATIONS PRIOR PAGTEL (800) 422-4133
IgTH (5R 30) w 5T TO FINAL PLACEMENT. PERFORM PRELIMINARY 5TRIPIN6 LAYOUT PRIOR TO LOOP DETECTOR CUCAMONGA COUNTY WATER DISTRICT (qoq) 987-2591
2. Traffic 5ignal Plan LAYOUT. (WATER AND 5EhIER)
PROJECT LOCATION' y UNDERGROUND SERVICE ALERT (800) 422-4133
y
Lu zd�
� J
FOOTHILL (5R 66) > BLVD
Q p
pQ J
1-10 Q m NO SCALE
v
> Q i
ST ___ '75mm
400mm 200rrmUC-I5OrmnLG _ 50mm
�_ 0400
�lOOmm
T
L 13mm
I.I.S.N.S. LEGEND DETAIL
PELGO ASTRO-MINI-BRAG
NO. AB-0155-L OR
AB-0132-L OR
FLAN5 FOR THE M0 [7� IFICwATION OF APPROVED EQUAL
O
TRAFFIC,* 510NAL5AN [;)
INTERSEC...* TION
LIOHTINO
A ""F HI
EMERGENGY VEHICLE
OPTICAL 5EN50R INSTALLATION
(f.., ARNELIAN 508FREET ANE�� IqTH 5TREE (5R 50) EMERGENCY VEHICLE PRE-EMPTION
No. REV15ION APPR. DATE
}t
Y
CITY of RANGHo C:UGaMoN�a
..
e tri c TITLE SHEET
CARNELIAN STREET
AT
A" OIMENs10te me IN METERS. IGTH STREET (SR30)
UNLESS OTHE RISE NOTED.
PLAN5 PREPARED BY: GENERAL INFORMATION AND DETAILS
DQE E SS/� N IAT APPROVED BY DATES '
HI LLDA ASSOCIATES 249536
Q N R.G.E. NO.
12gOO Crossroads Parkway 5ovth, Suite 200 CITY ENGINES
1� y DE51ON RE GO M _NPL D
Industry, GA 81746-34gq � o
z (562) q08-6200 BB s w
No. 45729
Exp. 12-31-02 * UNDER THE 5UPERVI ION OF: DRAWN BB 51I���
s� 9
GHEGKED DRAWING NO. �
�\
OF A` HERBERT L. 6L E51NC-', JR. RGE 45-12q DATE '_j
CS
CONDUCTOR SCHEDULE ■ 212L 212U
RUN No. F -1 r-- —1 POLE SGHEOULE ■
AW6 OR GABLE CIRCUIT LIA, 3 4 PED POLE LOCATION
STANDARD LU„tINAIRE VEHICLE 51GNAL MOUNTING SIGNAL PPB (5EE TITLE 5HEET)
FOR POLE I _ _ _ 1L No, 1.1.5.N.5. REMARKS
FOR POLE 13 I Q J
NPE SIG. LUM. V MAST ARM POLE MT&. IV AD ARROW LEGEND E B G
3 II III ,� MATCH LINE - SEE BELOV�I LEFT
FOR POLE G I I i i n n i n I I � � M.A. M.A. SEE DETAIL ori SHEET I
LOOPS 5G IUiI Jn a
FOR POLE V I v� 5JgU 24-4-80 35' 15' 250W(N) MA5(R), MA5(N) SV-I-T(N) 5P-1-T - - - Icith �' (N) EX151 ING "I
I lir nir li
GONOMTOR FOR POLE L I I I p p _ _ _ _ W T
B IA TV-2-T(N) SP-I-T EXIST INC
FOR POLE F I I I I ly- G 24-4-80 35' 15' 250W(N) MAS, MAS SV-I-T(N) 5P-1-T 5 W LT(N) Gorne I ion ;' (N) E X 1 ST I N6
16NA
FOR POLE GI, I EX. 41 G., v EX. 41 G., D IA - - - - TV-2-T(N) 5P-1-T 2 N RT(N) - EXISTING
FOR POLE ri I I INSTALL 2 DLG INSTALL 3 DLG
TOTAL 6 4 2 2 E 24-4-80 35' 15' 250W(N) MAS(R), MA5(N) 5\/-I-T(N) 5P-1-T 2 N LT(N) Igth 5T (N) EXIST INC "F-"=
FOR POLE 1 I I 4.2 3.6 1 3.6 3.6 4.2 F IA - - - - TV-2-T(N) 5P-1-T 4 E RT(N) - EXISTING
FOR POLE 0 1 I 6 24-4-80 35' 15' 250W(N) MA5, MAS 5V-1-T(N) 5P-I-T - - - GorneIion s, (N) EX151-INO
12 FOR POLE G I I I ,
FOR POLE v I I I H IA - - - - TV-2-T(N) SP-I-T ' W TNR - EXIST ING
CONDUCTOR FOR POLE I I I w USE EXIS I TNG MID 1 F NON
FOR POLE F I I I I I ALL EQUIPMENT IS EXISTING UNLESS OTHERWISE NOTED:
FOR POLE � I I �- -� SJIU PHASE DIAGRAM
- - - V i F � G EX. 51ON (N) = NEW
FOR POLE N I I LOOPS SG __ _ -- 213U p � �1 � � 1 1 GROUP A GROUP B
LUMINAIRE TOTAL 8 4 2 2 UJ (� = RELOCATED -
$ LU 2 2 2 04) w I
1 2 2 2 2 3L 1 i 4ly
z
#10 516. COMMON 2 I 1 1 tf� p I i
TOTAL 2 3 3 3 I v F- I -1 I G 200W LUM (pi m2 m3 m4
04 SE_R�/IGE 2 2 (Y �- - � I I F- ?
ml DEIEGIOR5 2 I 1 rJ door,- RE
_ - --
m2 DETECT ORS 4 4 4 Q Y I Y SCALE 1:200 ry 4 —�
03 DETEGIOR5 2 2 44 F- 7 1 1 1 SG L Z I � — �
G 04 DETEGIOR5 4 4 N(,�TG{-� I�(� O I F 7 1 1 1 T
-44 6 ll -1 � - i r
PLG m5 DETECTORS 2 2 2 — SEE ABOVE RICHT I I iambi
m6 DEI EG TORS 4 LOOPS 56 m5 416 m7 m8
ml DE T EGI OR5 2 2 SG LOOPS
m8 DEIEGIOR5 4 4 i — ' �I r� EX. 41 G.,
TOTAL 24 12 6 6 g� '� _ _ _ _ PV 4)6V - - —< 9 EX. 41 G. 5G LOOPS INSTALL 2 DLG
EVP GADLE 4 2 1 1 CARNEL
I
AN
CONDUIT SIZE R/W 5 O � � H INSTALL 3 DLG STREET SG LOOPS
EXI TING -1 15 63 63 (P4 j 3 (P4 R/W
( 5 ) - - - - LL - - - - - -
RE-MOVE E X 15 T I NG GONDUG 1 OR5 AND R20B(MOD) - % �4
INSTALL NEW THROUGHOUT. - - - -- - - - - 200 mm - -- - — ----
82(45) �4 RG VEH HEAD
-
200 MITI RG (P3 --
LUM IRGVEH HEA 1111 -� -� d) I I J
4 loll l -__J L -J `t I L- —J
(P4
m R-13-3 6 I RL 300 mm II r m 89.0 TO \F- - 135.0 TO \F- -1
m mod 1 VEH HEAD I J L -J m ' v GRO55HALK L -J GROSSWALK L -J
�t
- o (_ —i E -1 F —1 — 03 -
L -J LiL - r
- - - -
� f� � m - - - - - - - - - - F � F \ � 300 mm RL Im3dm 6 R-73-3m
Q F 105
-1 .0 TO 55.0 TO
d) L- 4GRO55WALK L_ -J, GRO55HALK m L --L - �1 \,/EH HEA
J F -1 I d) F- 7 I d� F -1 F \\� 200 mm 2 I RG LUM d)
L - I �- --� 1 SG LOOPS L L \\� G VEH HEAD
J J - - - 4P7m� 200 mI 5
G
- C
VEH HEAD
R2(45)
2 4 ,� � �-, [ R20B
LOOPSEp EX. SERVICE FEED
3 2#4(516), 2#8(LUM)
POINT (PP#215gIblE) AND 2#10(IISNSN) 4)2 � � 05r� /
EX. 41 G., EX. TYPE 5CE-1 RG # LOOPS 5G 2A\ I I L -J i / B
INSTALL 2 DLG SERVICE EX. 41 G., INSTALL 3 DLG, 2 4(516), _ �' -- I L -J O
2#8(LUM) AND 2#10(II5N5) � I I I � / SG LOOPS
53 G. WITH PULL ROPE I m2d I
G 1 - I I )
(CONDUCTORS BY EDISON) L C ND
I EX. 41 G.,
L . �°
5 -� I 1 L INSTALL 3 DLG - EMEROENGY VEHICLE 5EN50R
MATCH LINE SEE BELOW RICHT I
L -J I I6 3L ` '/—', ii - EXISTING RED GURB
200W LUM RG I I IU I I GONSTRIXTION NOTES
i EX. 41 G., ¢ 4 I I (FOR 6ENERAL NOTES, SEE TITLE SHEET) e tr�c
5ERVIGE: 120/240 V. TYPE III GF PER E5 2F
INSTALL 3 DLG
ElMODIFY EXISTING TYPE 1-70 CONTROLLER AND CABINET A5 REQUIRED TO
IOOA / 240V / 2-2P MAIN GBE SI6NRG IPROVIDE THE NEW PHA5ING, DETECTOR INPUTS AND EVP 5Y5TEM AS 5HOP4N.
30A / 120V / IP GB (LIGHTING) SL a R-13-3 6 I ALL DIMENSIONS ARE IN METERS, UNLESS OTHERWISE NOTED.
50A / 120V / IP GB (516NAL5) O I �� L -J I I a INSTALL NEW 13ACKPLATE ON EXISTING 300 mm PV VEHICLE HEAD.
15A / 120V / IP GB (IISNS) ~
T Q O ! FilREMOVE EX15TINO 5ERVIGE RISER AND INSTALL NETYPE H 5ERVIGE RISER.
5GTYPE V PEG WITH 50 SECOND TIME DELAY (L 6) � LOOPS W
TYPE V PEG WITH 50 SECOND TIME DELAY (IISNS) p INSTALL 51NOLE DIRECTIONAL EMERGENCY VEHICLE OPTICAL 5EN50R ON
6J3U I I D 51ONAL MAST ARM PER DETAIL 5HOWN ON THE TITLE SHEET.
� � I I
F -f F I No. REVISION APPR. DATE
� � 1 5
L -1 L I a I REPLACE 51ON FACES
V 4.2 3.6 3.6 ) 3.6 4.2 I TO CONFORM TO DETAIL ON TITLE SHEET. CITY OF RANCHO OXAMON6A
F -f I � a INSTALL SIGN ON MAST ARM PER DETAIL U ON E5-6T
. 3: L -J � TRAFFIC S I C NAL PLAN
i .
CARNELIAN STREET
w AT
EX. 41 G., --- I q TH STREET (SR 30
O INSTALL 2 DLG `
ly of t S S/ PLAN5 PREPARED BY: APPROVED BY DAIS , --
�N91 WILLDAN ASSOCIATES CITY ENGINEER R.C.E. N0. 24953' 0
N
0 12900 Grossroods Por" 5ovth, Suite 200 DESIGN RECOM� DED _O
, Indtistry, GA 81146-3496 BB V J�
MATCH LINE - SEE ABOVE LEFT No. 45729 (562) 908-6200 DRAWN SHEET N
L I L J 5G LOOPS * Exp. 12-31-02 * UNDER THE 5UPERVI I OF: BB 2 OF 2 9
&J21.) (9-12L 'flglf C�VI`\FQ �� `� CHECKED DRAWING NO.
°F cAt S
PLAN ACURATE FOR ELECTRICAL NOR< ONLY L6 1-7 i l-
HERE3ERT L. GLUE TNG, JR. RGE 4 l29 DATE
C�