HomeMy WebLinkAbout1793-S INSTALL BOLTED TYPE POLE PLATE - ATTACH TOP OF SV-2-T TO POLE PLATE GENERAL NOTES * IF X = 10' USE THESE DIMENSIONS 0 ** IF X = 11 ' USE THIS DIMENSION WITH OTHER X DIMENSIONS w 1. Traffic signal and highway safety lighting systems per CALTRANS Standard Plans and Standard Specifications dated July 1 992 , as shown on the plans and in the Special E.C.R 77 Provisions. ® CROSSWALK = DOUBLE YELLOW STRIPE STRIPE w 2. Traffic signs, stripes and legends per CALTRANS Traffic Sign Specifications, Traffic O OR MEDIAN CURB FACE OR Manual, Maintenance Manual, and Standard Specifications. Conform pavement legends LIMIT LINE O = to city stencils. Reflectorize all signs, stripes and legends. FIVE SECTION � O � 2'* SIGNAL HEAD 3. Pavement markers and painting procedures for striping per Standard Specifications for ' 3'** Public Works Construction, latest edition. ® THREE SECTION "B" -"B" A SIGNAL HEAD °G 4. Locate all substructures prior to construction. Hand dig foundations until clear of ' J4) ' REFER TO PLAN FOR REMAINING LOOPS 5'* r 0 obstructions. Coordinate pole installations with overhead utility or substructrure X* 0 owners. Phone Underground Service Alert and concerned utility companies 48 hours l prior to construction. Location of utilities and substructures have been shown from a search of available records. The Contractor shall conduct his operation in such a manner as to protect not only the utilities and substructures shown, but other utilities LEFT TURN LANE 3'* or substructures that may not be shown on these plans. U 8" WHITE TURNING LANE LINE m 5. Obtain approval for exact equipment, crosswalk and limit line locations prior to final TERMINAL COMPARTMENT X-6' placement. Perform preliminary striping layout prior to loop detector layout. 2 POLE LOCATION CODE 6. Vehicle indications shall be 12 pullboxes No. 5 and conduit 2" rigid metal except as FIVE SECTION SIGNAL HEAD __ _ _ _ _________ shown. 710' EXACT LOCATION BY ENGINEER IN THE FIELD 7. Electrical services shall be 120volt/240volt. Provide circuit breakers for signals (one X 6 50 amp metered), illuminated sins (one 15 amp metered), and safety lighting (one 30 am� per 1200 watts or portion thereof unmetered). Coordinate service details and MOUNTING DETAIL scheduling well in advance of need. B. The CONDUCTOR SCHEDULE is furnished as an installation guideline only. It shall be X-6' the Contractor's responsibility to provide the correct conductors required for the INSIDE THRU LANE 2 intended operation. NOTE: NOTE: 4" LANE LINE OR 8" TURNING LANE LINE ALL SECTIONS 12" ALL SECTIONS 12" 3+ NOTE: ® ALL SECTIONS 12" Q f NOTE: 10'F7 6' ALL SECTIONS 12" } Y R Y 3 » STit ,� ,� ,� �, G Y GoF F(M 7 16/ 8 UC-61C , » 2 ourslDE THRu LANE ( � 4" UTILITY COMPANY Y G Y 1040 --- CO Y TEL. NO. A> <A) NA 5' 1 ' G .:.s w ALL DIMENSIONS TO OF STRIPE T ELECTRICITY _ A A A AL )JulGAEO S _ SOUTHERN CALIFORNIA GAS COMPANY� (800) 227-2600 PHONE - VERIZON CORPORATION 909 608-1230 - PACIFIC TELEPHONE COMPANY (800) 227-2600 MAS-5A WATER - CUCAMONGA COUNTY WATER DISTRICT (909) 987-2541 DETAIL "A" DETAIL "B" DETAIL "C" LOOP DETECTOR PLACEMENT �+ �+ SEWER - CUCAMONGA COUNTY WATER DISTRICT (909) 987-2541 R.1,G = 02, 04, 06 or 08 _ _____ -_ _.__.____:_._ __. ___..- ____..^ I. I. S. N. S. LEGEND DETAIL CABLE T.V. - COMCAST CABLEVISION (909) 890-0886 YA,GA = 01 , 03, 05 or 07 _- --..____ _____,._ _ UNDERGROUND SERVICE ALERT (800) 227-2600 REFER TO PLAN FOR DISTANCE SIGNAL DISPLAYS TO ADVANCE DETECTORS SINGLE INPUT REMOVABLE EMERGENCY VEHICLE STEEL CAP IMUM ZW SAN MANAMM PREEMPTION DETECTOR 8'-0" ARM LENGTH N N O 60 24 1 1/2 TO 3/4" 5EE » » REDUCER SIGN TAB" 4e 12 �~ 16 16 16 DETAIL INDEX OF SHEETS PELCO AB-0155-L 1 OF 2 TRAFFIC SIGNAL ELECTRICAL DETAILS OR AB-0132-L 0 V'Ista 2 OF 2 TRAFFIC SIGNAL PLAN PKWY Terra Vista Parkway and Mountain View Drive 'COUPLING AT MAST ARM 11500 BOTTOM–FOR GR ` (NIPPLE & A WNA L 6OR » –� 6» CBYY OTHERS) 8'-0" e — __ _ _ __= HIGHLAND AVENUE NOTE: LB CONDULET, STO CABLE, HANGING AVOU HARDWARE & SIGN BY OTHERS = _ _ _ = _ _ — ARM TUBE SIZE GENERAL NOTES 30 TM riiiiii r�� su s MAST ARM LENGTH END O.D. x BASE O.D. x THK. MATERIAL SPECI ICA IONS PLW SHAFT Steel of 48,000 psi minimum yield after fabrication 5 8'-O 2 3/8" x 3 1 2" x 1 1 GA. MOUNTING CLAMP FOR ASE PLATES ASTM A-35 Steel ASTM A-36 Steel FLANGES W UNE BACK CLAMP IPE ASTM A-36--53 Grade B Steel Y ROAD NOTE: SPECIAL PROVISIONS F O R W/4 BOLTS MATERIAL SPECIFICATIONS EVP OPTICAL DETECTOR (ASTM A-307) BUTT WELDS Ground flush with base metal '' L - .j— THIS WORK ARE ON FILE IN LONGITUDINAL All welds shall conform to AWS D1.1 weld SIGNAL POLE WELDS specification / THE OFFICE OF THE CITY DIAMETER AT FINISH COATING AGUE ENGINEER. 24' ABOVE STRUCTURE Hot dip galvanized per M A-1 �' ' -' � FILE: TRACT MAP N O. 15492 – � FINISHED GRADE auio� I , HARDWARE Hot dip galvanized per ASTM A-153 66 F01i BOULEVAnD I EXIST. C & G DESIGN CRITERIA 1 STRUCTURE & In accordance with the Specification for Structural 4 R CLAMP HARDWARE Traffic of nilsighway Signs, Luminaires and ARMa g AASHTO 1994 ROUTE KIM > EXIST. C & G MEMO NO DESCRIPTION OF REVISION DATE CITY o WELDING In accordance with the Specification for Structural 15 ACCEPTED "R" CAB. v "R" _ , 1/2* DIA. Supports of Highway Signs, Luminares and CITY 0 F RANCHO CUCAMONGA W CAB. �= DEBURRED Traffic Signals. AASHTO 1994 ° PAD SIGNAL POLE HOLE IN o "LAMPnuNrY LW TRAFFIC SIGNAL a 16 DIA. HOLE 1N STREET ARAV! IES =■� 3" CLAMP SUPPLIED ELECTRICAL DETAILS 10" WITH A TYPE "F"8 � ARM _ _ �� PIAN SECTION _ DINT'UNCINGLUNT 3" 47H SrREET TERRA VISTA PARKWAY + SCREW (PILOT HOLE RAD. (HOLD) TO BE FIELD AS REQ'D. =Y 4W MM)WI AND MOUNTAIN VIEW DRIVE DRILLED) !! !! NOTCH OR DRILL 3" RpFESSI APPROVED BY: a DATE: TYPE R CABINET FOUNDATION AND �~ 0�, HOLE RAO. 1" Q – FOR DRAINAGE W/GROMMET 4 N 4 2 R� � ��� � S• E���` CITY ENGINEER///' �' ��C�l�f � R.C.E. � 24953 IN POLE 9 DIA ,`k. G S __. __ •.. T R A F F I SIGNAL LOCATION � F � - Ii (FIELD DRILLED) 16 DRILL W � - , DESIGN LAWRENCE S. EISENHART RECOMMENDED PAD DETAIL ����������������� CLAMP DETAIL SIGN TAB DETAIL � � -� � L.S.E. � � LOCATION MAP No. 13493 CONSULTING ENGINEER Exp. 3-- — * DRAWN 2070 Locust Court SHEET } San Bernardino, 2 / Os�qT CIV1� �� L.S.E. Tel: (909) 864-5406 CaliforniaFax.:(909)2864-5047 of HORIZONTAL I. I. S. N. S. MAST ARM NOT TO SCALE FOF CA CHECKED DRAVVIN N LAWRENCE 5. E SENHARI R.C.E. 13493 DATE CONDUCTOR SCHEDULE REMOVE "STOP;" MARKING PAINTSIGNAL MARKING POLE AND EQUIPMENT SCHEDULE PAINT SIGNAL MARKING A.W.G. SIZERUNS N E POLE SIGNAL STANDARD DIMENSIONS PLACEMENT SIGNAL MOUNTING PED PUSH BUTTONS HPS I.I.S.N.S. OR PHASE POLE OR CABLE SIZE NO. CIRCUIT Q Q Q QA. Q Q Q Q 1VN�IS l�V�l NO DESCRIPTION SIGNAL LUMINAIRE "C" "B" "E" POLE MAST ARM POLE ARROW LUMINAIRE LEGEND S MAST ARM MAST ARM VEHICLE VEHICLE PEDESTRIAN 0 1 ,6 POLE O 1 1 1 1 1 � -� REMOVE W17 SIGN DR 8 1 1 1 1 1 INSTALL W41 SIGN II�J II�f A 24-4-80 40' 15' 3' - 14' SV-1 -T AS-5A/M SP-1-CS 8 �-- 20OW Mountain View 7400 C , POLE 8 1 1 1 1 �{V �{V B 15 - 15' 3' 14' - SV-2-TA - SP-1-CS 6 —� 20OW - 0 12 6 O 1 1 1 1 W S I I I I C 24-4-80 35' 15' 3' - 14' SV-1 -T AS-5A M SP-1-CS 6 �-- 20OW Terra N 4'7 POLE C 1 1 1 0 o J - / 2 e a Vista 11600 D 6 O 1 1 1 a o Q D 15 15 3 14 - SV-2-TA - SP-1 -CS 4 —�- 20OW - U D 6 4 POLE ) 1 1 1 1 SCALE 1"=20' R-0 o,t x E 24-4-80 40' 12' 3' - 14' SV-1 -T AAS-5A/MASSP-1 -CS 4 �- 20OW Mountain View 7500 C U 2,5 1 1 1 I I III -"-de III�( •� F 1-A (10') - - 3' 14' - TV-2-TA - SP-1 -CS 2 - T C 4 POLE EO ' I `�a`�Z 0 Y I G 19-4-80 25' 12' 3' - 14' SV-1 -T MAS-5A SP-1 -CS 2 �— 200W errs Vista PKWY T O 1 1 1 1 Y J �, 11500 S 3 0 6 2 POLE F 1 1 1 1 NOTE: 3 o>aW H 15 - 15' 3' 14' - SV-2-TA - SP-1 -CS 8 —�- 20OW ALL SECTIONS 12" S R 3'8 POLE O 1 1 1 1 1 N No S 2 1 1 1 1 1 o W� _ 1 1 1 1 1 1 in v I �� o 2 POLE HO NOTE: > I NW 8 1 1 1 1 1 1 ALL SECTIONS 12" oN w 1 2 3 fi '� 2 XL8 8 o j ( I I JJ� TOTAL CABLES 12C/3C I I ( `) II I �W�o 1 2 3 fi 3 2 8 " I I Z9z r l I - —21 —�f 12'-+� 7 �- 6' 12'-+j 7' �—i —� 7' 12 I.I.S.N.S. 2 2 2 2 2 2 - - - ® 1 1/2 C. 1 DLC ' 1_ I Xo ' ' ' #10 LUMINAIRES 2 2 2 2 2 2 2 - - I I ! III I W TYPICAL 40 MAST ARIA TYPICAL 35 MAST AR TYPICAL 25 MAST ARM I � I 01 DEIECTOR 1 1 G ,,,� I IN$TALLATIQN DETAIL INSTALLATION QUAIL_ INSTALLATION DETAIL 02 DETECTOR 2 2 2 2 2 2 <A O I 03 DETECTOR 1 1 1 1 Y I 3 II I TYPE 04 DETECTOR 2 2 2 2 <A • G I `) <A O II C 05 DETECTOR 1 1 1 1 1 1 G I I III M III 8 D.L.C. 06 DETECTOR 2 2 <A ; 07 DETECTOR 1 1 1 1 1�s' 11' : 111 Y,G = 02 , 06 08 DETECTOR 2 2 2 2 " � I TOTAL D.L.C. - 3 3 4 4 1 1 12 12 YA,GA 0 1 , 0 5 1 1/2 C, 2 DLC 3 I , EVP CABLE 1 1 2 2 1 1 - 4 4 II `� II DETAIL C MAS 5A I , CONDUIT SIZE (IN.) 2 3 3 3 3 3 3 2-4 2-4 III I _ - ; 8 2 ' PROTECTED/PERMISSIVE SIGNAL DISPLAY 8 - de = - .. 7 - ECR " 4#10 (LIGHTING) BCR ---- ---------- -- d8 �; / ----- C ;U 2 C, 2#12 (I.I.S.N.S.) wl 1 O b N 3 .m -— 6 REMOVE "STOP" MARKING d .1 O D PAINT "SIGNAL MARKING — A 1/2" C, 2 DLC REPAINT "AHEAD" MARKING d DETAIL "C" P 3 d 6E - - - — 1 1/2- C, 1 DLC REMOVE W17 SIGN INSTALL W41 SIGN ` 6E _�- 05 Tp I _ slr� _- — ds n 02&05 as _ _ TO SERVICE r•, ��_-� _ OF Clips W LK 4OOR�p' --- DETAIL "c" --- _ --__ -- '•, _ ,•, --�-- - - - -_ X-WALK -- I _ I l _— . w -- -------- S - _ I _ ------- W ------------+ r--- W 1- QD 0 40 r -- 1 -- _ -_-__ W i --- -- W I I ---- w ---------- RAISED MEDIAN -------- -- --- -- N I I I ------ --------------------------- — ZV' N ------ --------- 2-W-15 M1 06 A I I I 1 ----- — - 1 ------- ;5 x5 10' 15to ' 6 -- - -- - -------------------------------------- - - - - y s _ X - 15' x 1 5 ,;1 I �- y 3 X 30' 1 02&05 _ MAS-5A - - FVP - _ ll S -_____- S Y - _ 11 A RAISEDMEDIANN RR ___ -__ DETAIL "C" d2 ' ` — �7 E ------ S --- ---- A T - ----- ---- Y S - - w - '�-r N I � ' ' I I ,•Yt __________________. 1 ' _____ W -- ---------------------- ------------------ _ W ---- W _ _ iA W - - Cf� W - --- --- ---- W - W - -- I I _. W ---------------- ------------ ------ T ---- W n 1 1 dcd8 ODA ' 1 - W --- __ --- ' 9z1 d W ---- C. -- -_ 3 E —` --- 6 —� H - --- 1 1/2- C, 2 DLC 8 6 / — � 1 1/2- C, 1 DLC \ a' 5 -f0 BACK U 7 ? ; IF APP�OX. 205 CROSSWALK °°� - ------ ----- ,- --- 10 OF ECR BCR -_ 40 BALK 6 - - N 2-S+d4 I REMOVE W17 SIGN I I III d III INSTALL W41 SIGN I REMOVE "STOP" MARKING I i I PHASE DIAGRAM PAINT "SIGNAL" MARKING III " " � III REPAINT AHEAD MARKING I 1 NOTE: SPECIAL PROVISIONS FOR I � w � III 3 ' THISWORK ARE N DECTECT R EN TABLE O O FILE IN O SENSOR SI > ; 01 02 03 04 THE OFFICE OF THE CITY SENSOR LOOPS PER CONTROLLER CONSTRUCTION NOTES DETECTOR 17 1 7' s 1 1/2~ C, 2 DLC ENGINEER. N0. CHANNEL SENSOR INPUT Q 1 Furnish and install 8 hose NEMA Type controller assembly with detector P YP Y 1 ❑ " " I .. . � FILE. TRACT MAP N O. 15492 1 1 -E-01 1 1 � sensors and auxiliary equipment in a Type R cabinet. See Special Provisions. I , 1 q I � II Exact location to be determined by the Engineer. I I Q 2 2-E-01 3 9 3 1 1 -W-02 2 2 0 — Furnish and install TYPE III-BF Service Equipment Enclosure with one 50A-IP .� 2 circuit breaker for metered signals, two 0 IP circuit breaker for unmetered ( II - -:d ' 1 1/2" C, 1 DLC -� 2 2-W-02 4 10 lighting and one 15A-IP circuit breaker for metered I.I.S.N.S. See S ecial III I I Q Provisions and Cit Standard Plan 407. Assigned address is 11600 Terra Vista 0 °f I 1 1 -N-03 1 3 Y g I , I * , 3 Parkway. o 'gym I ( I' I Y N0. DESCRIPTION OF REVISION DATE CITY 2 2-N-03 3 1 1 " a III ; Q I I ( YXCIUM ❑3 — Furnish and install 3 conduit do pull rope to SCE power source. (At the time ��N� I v a 4 1 1 -S-04 1 4 this plan was prepared the power source was not determined by SCE. It is N FW 3 m 05 06 07 �8 assumed that the power source is within 200 of the service equipment enclosure. N� 11 CITY OF RANCHO C U C A M 0 N G A 2 2-S-04 2 12 W o 0 If the ower source is a rester distance the extension of the conduit do pull roe � � o I � P 9 P P z � � W extra). _ will be considered ane v — z I 1 1 W 05 1 5 ) �Y o ,�, 5 2JJ0 TRAFFIC SIGNAL J o � S AL PLAN 2 2-W-05 3 13 ❑4 — Furnish and install single input EVP Optical Detector on signal most arm per 82 4 N o * = PERMISSIVE LEFT TURN MOVEMENT 1 1 -E-Ofi 2 6 detail on sheet 1. Phases shall be as shown on the plan. Verify locations o?� INSTALL JUMPERS IN CONTROLLER CABINET TERRA VISTA PARKWAY 6 prior to installing with manufacturer's representative. I ASSEMBLY FOR ASSURED ANTI-BACKUP 2 2-E-06 4 14 " I I I I 1 -S-04 I I 3 5 and PHASE 7. and 1 1 -S-07 1 7 0 — Fumish and install R73-7 (36 x45' sign per CALTRANS Standard ES-6T, Detail U. X O TO PHASE 1 , , 7 2 2-S-07 3 15 © — Existing street light to be removed by others. X. 3 MOUNTAIN VIEW DRIVE 8 1 1 -N-08 2 8 ❑7 — Furnish and install 1 1/2" conduit and 2-12 pair #19 signal interconnect cables. Q� X oQROFESS/ APPROVED BY: , DATE: 2 2-N-08 4 16 MS — Furnish and install 1-12 pair #19 signal interconnect cable in existing 1 1/2" conduit. �������� S £�s�yF CITY ENGINEER /(/ U �, +( fk . G j j R.C.E. 24953 ANA REMOVE W17 SIGN DESIGN RECOMMENDED 9 1 EVP 01 & 05 2 3 L.S.E. LAWRENCE S. EISENHART ��� INSTALL W41 SIGN I..,, Q ,�•, 2 EVP 02 & 06 3 No. 13493 CONSULTING ENGINEER _77� REMOVE "STOP" MARKING Exp. 3-31-05 * DRAWN 2070 Locust Court SHEET 10 1 EVP 03 & 07 4 SIGNA PAINT "SIGNAL" MARKING REPAINT "AHEAD" MARKING �f` P L.S.E. San Bernardino, California 92404 2 2 2 EVP 04 & 08 5 lql CMV ( � Tel: (909) 864-5406 Fax: (909) 864-5047 of OF CAl.�F " CHECKED DRAWING NO. �- � 7 q, S WRENCE S. E EN .C.E. 13493 DATE