HomeMy WebLinkAbout404-D GENERAL NATES NOTICE TO CONTRACTORS
1 . - All work shall be done in accordance with these Plans , the City of Rancho Cucamonga Standards, the California Depart- ° A11_ contractors and subcontractors performing work shown on or related*to
ment of Transportation Standards, and the Standard Specifications for Public Works Construction, 1979 Edition. Con- these plans shall conduct their operations so that all employees are pro-
tractor shall be familiar with and shall be responsible for adherence to these Standards and Specifications. vided with a safe place to work and the public is protected. All contractors
and subcontractors shall comply with the "Occupational Safety and Health Regu-
2. All pipelines or substructures of any kind and telephone or power poles, water meter, valves , hydrants, etc. , shown lations" of the U. S. Department of Labor and the State of California Depart-
or not shown on these Plans within the limits or in adjacent areas where improvement work is to be done, shall be ment of Industrial Regulations Construction Safety Orders.
removed or relocated as required at no cost to the City of Rancho Cucamonga.
The Civil Engineer shall not be responsible in any way for the contractor's
i 3. The responsibility of adjusting manhole covers, paving repair and paving replacement in connection with sewer and and subcontractor's compliance with "Occupational Safety and Health Regula-
water line installations will be the responsibility of the Paving Contractor at the completion of paving and shall be tions" of the U. S. Department of Labor and the State of California Department
accomplished in compliance with appurtenant ordinances and standards. of Industrial Regulations Construction Safety Orders. The contractor further
agrees that he shall assume complete responsibility for job site conditions
`. 4. Any Contractor performing work on this project shall familiarize himself with the site and shall be solely responsible during the course of construction of this project, including safety of all
for any damage to existing facilities resulting directly or indirectly from his operations, whether or not such facili- persons and property; that this requirement shall continuously apply and not
ties are shown on these Plans. be limited to normal working hours; and that the contractor shall defend,
!, indemnify and hold the owner and engineer harmless from any and all liability
F 5. A permit will be required from the City ofRancho Cucamonga Engineering Department prior to any encroachment or con- either real or alledged in connection with the performance of work on this
struction within the City of Rancho Cucamonga Easements or Rights-of-Way. project, excepting for liability arising from the sole negligence of the owner
or the engineer.
6. City approval does not include estimate of quantities.
F 7. Adequate stakes shall be set by the Engineer to enable the Contractor to construct the work to the plan grades. PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
8. Compaction tests of embankment construction, trench backfill , compacting original ground, and all subgrades shall be The existence and approximate location of any underground utilities or struc-
performed at no cost to the City of Rancho Cucamonga. A written report with these compaction tests shall be submitted tures shown on these plans are obtained by a search of available records. To
to the City Engineer for approval , prior to placement of base materials and/or surfacing, the best of my knowledge there are no existing utilities or structures except
as shown on these plans. The engineer assumes no liability as to the exact
9. Contractor shall notify the City of Rancho Cucamonga at least two (2) working days prior to commencement of work at locations of said lines ncrfor utility or irrigation lines whose locations are
telephone number 714/9891851 . not shown. The contractor shall be responsible for notifying all utility and
irrigation companies prior to work or excavation to determine exact locations
10. City approval of Plans does not relieve the Developer from the responsibility for the correction of error and omission of all lines affecting this work whether or not shown hereon, and for any
discovered during construction. Upon request, the required Plan revisions shall be promptly submitted to the City damage or protection to these lines.
Engineer for approval .
11 . Estimate of quantities is provided by the Engineer only for the convenience of the Developer, The Contractor shall
make his own determination of construction quantities before submitting a bid. Any item of work required by these
Plans which is not specifically listed in the estimate of quantities shall be considered as included in the other
items of work.
12. The approximate locations of underground utility lines are shown on these Plans. The Engineer assumes no liability
as to the exact location of said lines nor for utility or irrigation lines who locations are not shown. The Con-
tractor is to notify all Utility and Irrigation Companies prior to work or excavation to determine exact location
of lines. Underground utilities or structures were obtained by a search of available records.
48 hours prior to excavation, notify underground service alert, Phone 1-800-422-4133.
h
1 W< W >a FOOTHILL
LL � OLVD.
ARROW
RTE.
SITE
(SEE BELOW LT.)
8TH. ST.
W cr 3
Z W
K W Z
It W
H >
SAM BERNARDINO AVE.
01
i ONTARIO W
MOTOR W
0
SPEEDWAY
W
D
SAN BERNARDINO FRWY. RTE. 10
VICINITY MAP
NOT TO SCALE
I PUauC, STORM DRA1N REUI sEp PIR R>BLIL STc1ZM
J PKAjN PLAN A16U-P PM DRG 201-M393 Sr: 114AU4 A
FOOTHILL BLVD. DESCRIPTION OF REVISION
DATE APPROVED
�'
os' I ,►vE , CITY OF RANCHO CUCAMONGA
LYres
srREE7.
ON-SITE STORM DRAIN
PARCEL MAP 6725
Ar
U FROM FOOTHILL BLVD. TO EUCALYPTUS AVENUE
Q t P is h
Ae APPROVED BY DATE
14 1
9 =� ` s° e CITY ENGINE R.C.E. 23889
> 17 ,
Z AVENUE It1 DESIGN nG RECOMMENDED
obJ.+,,C,�r 9.
f'eWq/'cl
n,
L.D. KING INC.
Y� yF DRAWN 517 N. EUCLI D AVENUE SHEET
Co//%/�s
2TIO, CALIF (7 4) 988- 5 492 ! 0 F
BRANC MAN AG R CE 2106 DATE
ARROWSITE MAP E CHECKED DRAWING N0.
NOT TO SCALE G ✓ L. PROJECTG E GINEER R E 31875 hATE � �
I
t
n tir MW cove- eoeeooe pwr,*
DhEASCENori ��// Q v D161SCEN /r4V�/� ��. �/: i�I J ��7
srviE r
•,r,i,FCi suotuoFHtFCl. '`
f A I
10L 4
Q _ _ _ - -
V _
- _ _ -
b t L
� `� , -
�. _
d _ -
_ _
Fyl - - -
1 _
-_ - _
A. -_ - _ - _
- . O -
a1 , . 1 y It Of
�00
_
- -
Scale
• ,
Albrl
0 vert. .• /"=Af' 2 3 4
(E
1
Sco% : /"=40' \
i
1
37f00.D foothill alvd. ' " - ��
z
K Jurvey
/ o• AnlO XA' SE/KEArr
0
D y �
C47 .
s' Ies" o / I o, SEE- DRAWOA; 14MA4/362 /,rfZ L-A
1h +8s.92 kE s=O♦oa oo GF•oi s
der Sio%wcr/K Orcr n- Type / °� 1zE•l/lS ?''0"
'[lIl
W-
_ Anh •
3 � �/1.tE/lTEw/
I
001W.0B0 rod l*a�r spa 016;0/1t•
,
I �T^ eyin 24"R.C.P01
--Noe G' .2,2"'W— — — — — — — — — -- — — — -- — — — — — - - -- -- -- Q I
DESCRIPTION OF REVISION DATE APPROVED
v CITY OF RANCHO CUCAMONGA
V n11k ,��, PLAN AND PROFILE
S0 1MI o ON-SITE STORM DRAIN
jCorns tru c ti o Ab fes 4m jE3 ti male Ojo. Qvrrst ti ties- V I
/ Cdn.st Oraina�epreZsio"
e /nt Tpoe GO Per Cal Trans Std. P/an No. D74-/4 / Ea►. ' V PAR�iE�. MAP 725
s
Const. GvtteryPer Ca/ Trans Std. P/an No. 07B-,2 2 Eo. �. FROM f`OOTHILL BLVD. TO EUCALYPTUS �►�/ENUE
{
Const. Under Sidewo/K Dv-c>I►in-Type / Per C�fy OfRoncho L'v['a►man90 hl11ISN
Std. Diowin9 Ab. 306• / ,Eo. f�f Arc• APPROVED 8 DATE
/nsta// .Z4"R C.P 387./7L.F Op �� CITY ENGINES R.C.E. 23889
DESIGN RECOMMENDED
C. Stewa►ro' L.D. KING INC. ��✓.fofC6�E:N�c.
E1177AVS• DRAWN 517 N. EUCLID AVEIME SHEET
' D.L. Co//i!'fs 0 TA R I AL F. 714) 988-15"Z_ — Of�
CHECKED 8RANCN MAN E RCE 21062 DATE DRAWING N0.
G ✓ L . R�OJEC GINEER `RCE 31875'DATE
S 1-¢C(