HomeMy WebLinkAbout78-22 - Resolutions RESOLUTION NO. 78-22
A RESOLUTION OF THE RANCHO CUCAMONGA PLANNING
COMMISSION TO APPROVE DIRECTOR REVIEW NO. 78-21 FOR
THE DEVELOPMENT OF A RETAIL/WHOLESALE LUMBER FACILITY
TO BE LOCATED AT 11747 FOOTHILL BLVD.
WHEREAS, on the 4th day of August, 1978, a complete applica-
tion was filed for review on the above described property; and
WI~EREAS, on the 25th day of October, 1978', the Rancho Cuca-
monga Planning Commission held a meeting to consider the above described pro-
ject.
NOW, THEREFORE, the Rancho Cucamonga Planning Commission
resolved as follows:
SECTION 1: That the following findings have been made:
1. That the site indicated by the development 7
plan is adequate in size and shape to accommo-
date the proposed use, and all yards, spaces,
walls, fences, parking, loading, landscaping
and other features required by the Zoning Ordi-
nance.
2. That the improvements as indicated on the develop-
ment plan are located in such a manner as to be
properly related to existing and proposed streets
and highways.
3. That the improv~nents as shown on the development
plan are consistent with all adopted standards and
policies of the City of Rancho Cucemonga.
SECTION 2: That this project will not create significant adverse
impacts on the environment and a Negative Declaration is issued
on October 25, 1978.
SECTION 3: That the Planning Commission sets the following con-
ditions on the above described project:
En~ineerin~ Division:
1. At the7 time of development, grading, drainage, and
street plans prepared by a Registered Civil Engineer
shall be submitted for review and approval of the
City Engineer. HydraUlic calculations and a topo-
graphic map will be required to support the sizing
and location of drainage stcuctures shown on the
plans and those required by development.
2. Sewer and water plans shall be coordinated with
the Cucamonga County Water District prior to
development of the individual pardels.
3. At the time of development, curb, gutter, drive
approaches, sidewalk, and A.C. match-up paving
shall be provided along Foothill Blvd.
4. Street lights are required along Foothill Blvd.
The developer of each parcel shall submit all
necessary plans for installation to the Southern
California Edison Company.
5. Surface drainage from the site to the street shall
be by a parkway drain, per City standards to outlet
flow into adjacent streets.
6. The proposed site is subject to periodic inundation
due to 100 year storms. Flood protection measures
comprised of the raising building pod elevations,
construction of walls, berms, and protective roles
on drive approaches shall be utilized to insure
protection from 100 year flood. Prior to final
approval precise protective measures shall be
approved by the City Engineer.
7. The designer shall in no case create a potential
flood hazard to proposed or adjacent developments.
8. The design should not gather waters by artificial
means and discharge them onto other (lower) proper-
ties in greater concentration than would naturally
be discharged nor should it dam or obstruct the flow
of surface waters from other (higher) properties
that naturally drain across onto the property in
question.
9. The designer may be required to obtain or provide
drainage easements and construct improvements.
PLANNING DIVISION:
10. That all provisions of the Zoning Ordinance are
complied with.
11. That the site be developed in accordance with the
approved plans on file in the Planning Division.
12. That a detailed landscape and irrigation plan be
submitted to and approved by the Planning Division
prior to issuance of building permits.
13. That the proposed fencing on the east and west pro-
perty lines be reduced to 3' in height within 25'
of the front property line.
14. That a coordinated sign program be reviewed and
approved by the Planning Division prior to installa-
tion.
15. That the roof facade be carried around the
entire east elevation of the front building.
16. That the applicant comply with all fire protection
~provements per the requir~ents of the Foothill
Fire District.
17. That the service entrance gate be moved back flush
with the front of the building.
18. That there shall be no sales display in front of the
landscaped berm.
19. That the nursery display area details be reviewed and
approved by the Planning Commission.
20. That encroac~ent pe~its are obtained from Cal
Trans prior to doing any work in the right-of-way.
~PROVED AND ~OPTED ~IS 25~ DAY OF OCTOBER, 1978.
PLANNING COMMISSION OF THE CI~ OF RANCHO CUC~ONGA
Secretary of the Planning Commission
I, Jack Lam, Secretary of the Planning Commission of the City of Rancho Cucamonga,
do hereby certify that the foregoing Resolution was duly and regularly introduced,
passed, and adopted by the Planning Commission of the City of Rancho Cucamonga at
a regular meeting of the Planning Commission held on the 25th Day of October, 1978,
by the following vote to-wit:
AYES: COMMISSIONERS: GARCIA, JONES, DAHL, REMPEL
NOES: COMMISSIONERS: TOLSTOY
ABSENT: COMMISSIONERS: NONE