Loading...
HomeMy WebLinkAboutHeritage Pk scoreboards i GENERAL NOTES _ ,' R ('; �,, , ' �•, _. __ 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS,THE CITY i - _ - OF RANCHO CUCAMONGA STANDARDS,THE STANDARD SPECIFICATIONS OF C`40 _ PUBLIC WORKS CONSTRUCTION CURRENT EDITION -_ '-�._ , AND CHAPTER 70 OF / ' THE BUILDING CODE(LATEST EDITION). CONTRACTOR SHALL BE FAMILIAR WITH AND SHALL BE RESPONSIBLE FOR ADHERENCE TO THESE STANDARDS i AND SPECIFICATIONS. - F X IST INN ( � { , (, } -� 1 '� �" 2. A CONSTRUCTION PERMIT AND BUILDING PERMIT SHALL BE OBTAINED r --s.__. ' ���� FROM THE CITY OF RANCHO CUCAMONGA ENGINEERING DING �1cH-� �u� T YP) �-�� • --�. - RING AND BUIL ` DEPARTMENT, RESPECTIVELY, PRIOR TO ANY CONSTRUCTION. 3. ANY CONTRACTOR PERFORMING WORK ON THIS PROJECT SHALL j • FAMILIARIZE HIMSELF WITH THE SITE AND SHALL BE SOLELY RESPONSIBLE • I . '� ,. " - / SAW-CUT @EXISTING SAW-CUT LINE OR ALONG EXISTING EXPANSION JOINT. .SAW-CUT REMOVE & PATCH EXiSTING CONCRETE FOR ANY DAMAGE TO EXISTING FACILITIES RESULTING DIRECTLY OR REMOVE AND REPLACE CONCRETE. REPLACE EXPANSION JOINTS AS NECESSARY INDIRECTLY FROM HIS OPERATIONS, WHETHER OR NOT SUCH �'- - j �` . • TO MATCH ORIGINAL ICAL). ARE SHOWN ON THESE PLANS. FACILITIES - �1 ._ EXISTING 4. CITY APPROVAL OF THE PLANS DOES NOT RELIEVE THE DEVELOPER FROM SOFTBALL F. EL # * I I , j + • 'rte'- `+ . �. 1 RESPONSIBILITY OF THE CORRECTION OF ERROR AND OMISSION ! i .� < r, ,� : �. `i '<< •\ ..� " t I �> > O ' SOFTBALL FIELD #2 PLAN REVISIONS SHALL B DISCOVERED DURING CONSTRUCTION. UPON REQUEST THE REQUIRED • , PROMPTLY SUBMITTED TO THE CITY ENGINEER 0 Heritage Park M • • 1 FOR APPROVAL. i / tr ' 0 S. CONTACT ALL UTILITY COMPANIES AS REQUIRED 48 HOURS PRIOR TO ANY EXCAVATION. 4 I VICINITY MAP',,.. ' i u 6. WORK SITE SHALL BE MAINTAINED IN A NEAT, CLEAN, HAZARD FREE, �l • ORDERLY STATE,THROUGHOUT CONSTRUCTION. SITE SHALL BE • / } ` '✓ �� ' , __. -�- � � CLEANED UPON REQUEST OF THE CITY INSPECTOR �� ` % � , \~• � 1 � � � 7. THE STRUCTURAL ENGINEERS REPORT PREPARED BY WOOD ENGINEERING, INC. DATED APRIL 4, 1995, BY THIS REFERENCE, IN MADE A PART HEREOF, AND IS ON FILE IN THE CITY ENGINEERS OFFICE. 1e�c 71t �, 1-i f4j,;�7, f 8. A GOOD EFFORT AND CARE SHALL BE MADE TO RE " MOVE, PROTECT AND REPLANT THE EXISTING TURF THAT IS REMOVED BECAUSE OF THE I _ TRENCHING OPERATION. ANY TURF THAT IS DAMAGED SHALL BE REPLACED IN KIND. i 9. THIS DESIGN IS DIAGRAMMATIC. ALL CONDUITS, JUNCTION BOXES, ETC. I '1 SHOWN ARE FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED PER DETAIL, MINIMIZING THE LENGTH OF CONDUIT RUN AND AVOIDING } EXIS• ING LEA 1 D H ANY CONFLICTS WITH THE IRRIGATION SYSTEM AND ARCHITECTURAL ! -CA. I• � � I ,/ FEATURES. !� _100 •' I 00 is u �,• / \._ I I I �•,Y _ 'sp� r rtof'�-t�p It _1% EXt T I w W - S I t , XISTIN,G a �4 SOCCE IED . , I I ' / 8S C E FIELD XIsT4 BALFILD IMPROVEMENTS BOREU14DEXISTING 1SiCEWALk `\ 1 / , \N1 . 1 1 . '' > looll V 1151 ,% - \ tJ 1830 29 - Sir- - y 28 7,211 27 NMTH \• � � y,/r � \ �.. ` _ exlstt" SIDEWALK IMPROVEMENTS � � 3w-� �26 1825 k4l �/ / _ - . . - JOG PATH _ 23 DESCRIPTION OF REVISION DATE »tr ODS N. NOTE: . • *�� asp o s ALTA LOMA LITTLE LEAGUEF BALLFIELD ..A14D SIDEWALK SHOWN As CITY OF RANCHO CUCAMONGAIt- 6 . 4 INC IMPROVEMENTS EXIST TS * HERITAGE PARK ARE SHOWN FOR SCORE BOARDS INFORMATIONAL PURPOSES ONLY. F OQ•� r \_ - •— ._ .. _.. _ . _ _ _ �-�. �- OF CA1.1F PLAN VIEW SCHEMA'T'IC I I \` APPROVED BY: DATE: � CITYENGINEER RC E NO 24953 ---� -- _ - -• -. _ _ _ f LD.L.A. IAN DAvmsoNDESIGN RECONINIENI DED -- _ - _ -- — — - DR AWN SHEET . __ • ` - rte_ f_ -• —--- .. ._..... .__.__. .. . . ._ ... . 4172 Kirk 9t. Yember A.8,L.A. or 'L Riverside,CA 92506 CA Re&tration 42651 CHECKED I•Yae 909.fS3.1=83 FAX 9WAU.435! RCE NO DRAWING III Jfl DATE to *-g FILE NO SPECIFICATIONS 1 . BASEBALL SCOREBOARD MODEL 1010 u 1.0 GENERAL: Scoreboard, UL Listed/CSA Certified, remotely operated from one (1) control station.* Displays outs,team scores, inning, balls, strikes, os, using low voltage 100% Solid State 2-WIRE cable multiplex system, quartz crystal controlled. 2. 8A SCOREBOARD:Size 101 x 4'H x 6"D,constructed of aluminum.Scoreboard color Green,polyurethane epoxy IZy. � OW I (Dfinish, with 1"white outline striping. Four(4) brackets provided for mounting. Woo t approximately 160 lbs. - 3.0 CONTROL CENTER: One (1) each Model MPC Microprocessor-based operator's control furnished. Construction of gray highly break-resistant plastic, size 12''x 12 x 5'. Includes: remote nand-neid time switch, �)L Y r�A' 2 2 twenty-five(25)feet of cable with connectors,keyboard overlay.Control features:bright traveling alpha-numeric �I II dot matrix LED display, lithium cell battery backup to retain memory, self test mode, power on-off switch, a-4 Y _ pltemate time switch internal beeper which acknowledges each entry, multiple scoreboard control capability. For scoreboards with timers,additional features:time of day display:time out timer with warning, interval horn, I I I2 upcount auto stop/hom, 1/10th seconds display during last minute. Control may be used to operate �! manufacturer's scoreboards for other sports by interchange of keyboard overlay. 40 DIMMER: Lamp i tensity day-night dknrner activated from operator's control center keyboard. 5.0 LAMP BANKS:4 x 7 matrix,recessed individual akxv*lum reAecxon, 16 watt kosted, 120 volt lamps, 1 E"high. e.0 TEAM SCORES:Two(2) scores 0-99. 5 7.0 INNING: Registers 0-9. BA INDICATORS:Lamps,Ohne baNs,two strikes,two outs, 25 watt frosted, 120 volt lamps. 6 9.0 CAPTIONS:Words, HOME,GUESTS, INNING,BALL, STRIKE,OUT,white letters 8"high. �P 7 1" CONTROL CABLE: One eq per scoreboard of 2-WIRE cable coaxial direct burial type) 1/4" ' �' ' _� Z diameter. Order cable r (iqulredd,fromr scor9bboard to point where control plugs in,from marwhacturer. 11.0 POWER: scoreboard, 20 Amp, 115 V. 80 Hz. Control CenMr, 10 watts. 115 V. 80 Hz Each requires earth ground. = a 12.0 dUNCTi0N1 I=:Or*(1)4"X 21/8"x 21/8"with cow,to be installed In dry location(press box),kxriiahed. R� NOTE:.ELECTRICAL CONNECTION SHALL BE PER THE UC AN 8 D NEC W ITN THE -MOST STRIN69NT CRITERIA OF THE TWO GOVERNING . 2 _5CORE BOARDS TO BE CONNECTED TO THE EXISTING TOUCH *AD Q AYSTSM LOCATED IN THE PANEL aooM. All ALEGEND Oy I. LE MEUR PEDESTAL TYPE CONTROLLER ENCLOSURE MODEL A JR. BOLT TO EXISTING COW. FINISH: 2 COATS DARK GREEN SEMI GLOSS 9,t I II 2 b ENAMEL. SEE PLAN FOR LOCATIONS. N u 1. 0A • �� 2. 120 VOLT GFI PLUG. MOUNT IN ENCLOSURE2 E 2 ` . d �7 � Z \ / 3. JUNCTION BOX FOR 2 WIRE COAXIAL CONTROL CABLE. V1 n. ° 4. 1"5C1k 40rWC-CND?W/ LOW VOLTAGE CONTROL CABLE. ° S. JUNCTION BOX FOR 120 VOLT. V� LEGEND p 6. 1"5cH.4opvC tNt7T W/ 3 #6 CU FOR SCORE BOARD, 30 AMP, 120 VOLT. 6 .�. 7. EXISTING COW.-SAW -CUT. SEE PLAN FOR LOCATION. COLIC. MOW CURD "S" BRACKETS (TOP a BOTTOMS „ „ AIL W W 2. 6 X 9 CONC. MOW CURB-RADIUS ENDS (SEE DETAIL). 3• SCOREBOARD (NEVCO MODEL 1010). 4. RAIN TIGHT CIRCUIT BOX (UL LISTED, CSA CERT., GROUND FAULT INTERRUPTER, 20 AMP.). MOUNT ABOVE BOTTOM OF SCOREBOARD MIN. 12' HIGH. 1. CONC. MOW CURB -ICAQILI6 IEX P05CP VAP&1!r6 S. LOCKABLE RAIN TIGHT POWER DISCONNECT (NON-FUSED) MOUNT ABOVE BOTTOM OF SCOREBOARD MIN- 12' HIGH. �. 1'I!'� SON T� 6. S DIA. GALV. STL. PIPE W/ END CAP (GAL.V.) @ TOP (SEE • LEGEND U Z, 7. POWER SUPPLY (RUN INTERNALLY IN PIPE). Z rC-L5^N GAU��I L-L- 1. PIPE CAP. 1: it. CONTROL WIRE (RUN INTERNALLY IN PIPE). s lA 2. 5/8" DIA HOLE IN BRACKET A PIPE (2 TOTAL EA. BRACKET). 9. FINISH GRADE. 3. "S" BRACKET- 4 TOTAL (SEE ISOMETRIC). 10. CONDUIT RUN (SEE PLAN). 0<-+- GONDU IT 4. SCORE BOARD 'I�IIIU 11. CONC. FTG. (SEE eNG(H Er4Q J G KVV0FlZT). S. 5/8" STAINLESS STEEL BOLT, WASHER. A BOLT. TWO EA. BRACKET. /� 12. "S" BRACKET. SEE DETAIL THIS SHEET. TY p �.N C-H CET^1 L 6. S" DIA. MOUNTING PIPE. NOTIE . COM PACT 174=_�V C 4 E5ACh1=I L.L..TO tAME. AS A XAAC�NT A 4D 1-0 " 901% COMPACT1Oh1 IN ALL- Fv4P75CAPM A L DESCRIPTION OF REVISION DATE CITY �O�N DSC,gp� APPRMD Z. 4' MIN . NOKIZONTAL GI-�AtzAhl� CITY OF RANCHO CUCAMONGA ZrZTWEEN rAA^LL1F_--1_ cc * ALTA LOMA LITTLE LEAGUE 7_77�t s * HERITAGE PARK '91�c 0���! SCORE BOARDS OF•CA1.�F DETAILS/SPECIFICATIONS f i.D.L.A. APPROVED BY: DATE. CITY ENGINEER( RC.E NO. DESIGN IAN DAVIDSON RECOMMENDED L uscAPE A culTECT !•-lY E 9 i DRAWN SHEET 6172 Kirk 3t. MenFKr A.S.L.A. l.J t�2 2 of 2 Riverside,CA 92506 CA Registration#2651 Phose 969 663 1293 FAX 909 693 435Y CHECKED DRAWING NO. I R.C.E.No DATE d ' �� FILE NO ,a y