Loading...
HomeMy WebLinkAbout3006-S GENERAL NOTES GENERAL NOTES (CONT.1 1. TRAFFIC SIGNAL AND HIGHWAY SAFETY LIGHTING SYSTEMS PER CALTRANS STANDARD PLANS 6. LOOP DETECTORS SHALL BE 6 FOOT BY 6 FOOT, EXCEPT AS NOTED. CENTER LOOPS IN THE • AND STANDARD SPECIFICATIONS DATED JULY, 1992, AS SHOWN ON THE PLANS AND IN TRAVELED PORTION OF THE LANE, EXCEPT AS SHOWN. ' THE SPECIAL PROVISIONS. • CASE 1 PPRP* N 7. VEHICLE INDICATIONS SHALL BE 12" PULLBOXES No. 5 AND CONDUIT 2" RIGID METAL OF DOUBLE YELLOW LINE SECTION CAB. 2. TRAFFIC SIGNS, STRIPES, MARKINGS AND LEGENDS PER CALTRANS TRAFFIC SIGN SPECT- EXCEPT AS SHOWN. ALL VEHICLE AND PEDESTRIAN INDICATIONS SHALL BE LED. '' , � OR MEDIAN CURB FACEFICATIONS, TRAFFIC MANUAL, MAINTENANCE MANUAL, AND STANDARD SPECIFICAl10NS. CONFORM • ► PAVEMENT LEGENDS TO CITY STENCILS. REFLECTORIZE ALL SIGNS, STRIPES AND LEGENDS. 8. ELECTRICAL SERVICES SHALL BE 120/240 VOLT. PROVIDE CIRCUIT BREAKERS FOR SIGNALS S ► . / A (ONE 50 AMP), ILLUMINATED SIGNS (ONE 15 AMP), AND SAFETY LIGHTING (ONE 30 AMP PER "R" CAB. ► oLEFT TURN LANE C14" 3. MARKERS AND PAINTING PROCEDURES FOR STRIPING PER STANDARD SPECIFICATIONS FOR PUBLIC 1200 WATTS OR PORTION THEREOF). COORDINATE SERVICE DETAILS AND SCHEDULING WELL SIDEWALK ' ' 0' 5' 10' WORKS CONSTRUCTION, 2000 EDITION. IN ADVANCE OF NEED. SEE SERVICE WIRING DETAIL HEREON. 5'X6' 5'X6' 5'X6' 5'X6' to PLAN SECTION * ir 4. LOCATE ALL SUBSTRUCTURES PRIOR TO CONSTRUCTION. HAND DIG FOUNDATIONS UNTIL 9. THE CONDUCTOR SCHEDULE IS FURNISHED AS AN INSTALLATION GUIDELINE ONLY. IT SHALL o CLEAR OF OBSTRUCTIONS. COORDINATE POLE INSTALLATIONS WITH OVERHEAD UTILITY OR BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE THE CORRECT CONDUCTORS REQUIRED 8-WHITE TURNING LANE LINE ih SUBSTRUCTURE OWNERS. PHONE UNDERGROUND SERVICE ALERT AND CONCERNED UTILITY FOR THE INTENDED OPERATION. W COMPANIES, 48 HOURS PRIOR TO CONSTRUCTION. LOCATION OF UTILITIES AND SUB- 2 THRU LANE M STRUCTURES HAVE BEEN SHOWN FROM A SEARCH OF AVAILABLE RECORDS. THE CONTRACTOR UTILITY COMPANIES PHONE NUMBERS SHALL CONDUCT HIS OPERATION IN SUCH A MANNER AS TO PROTECT NOT ONLY THE -j UTILITIES AND SUBSTRUCTURES SHOWN, BUT OTHER UTILITIES OR SUBSTRUCTURES THAT SOUTHERN CALIFORNIA EDISON CO. • �' 10' - v ARE NOT SHOWN ON THESE PLANS. (CONTACT David Quezada ) 909 357-6240 ' • *M CAS SOUTHERN CALIFORNIA GAS CO. 800 422-4133„R» • ► CAB ► 5. OBTAIN APPROVAL FOR EXACT EQUIPMENT, CROSSWALK AND LIMIT LINE LOCATIONS PRIOR VERIZON 800 422-4133 SECTION = TO FINAL PLACEMENT. PERFORM PRELIMINARY STRIPING LAYOUT PRIOR TO LOOP DETECTOR PACTEL 800 422-4133 4" LANE UNEM LAYOUT. CUCAMONGA COUNTY WATER DISTRICT 909 987-2591 A I�- a I WATER AND SEWER) " SIDEWALK ►, . / THRU LANE N Z UNDERGROUND SERVICE ALERT (800) 422-4133 R CAB. o SIDEWALK ' 10' PLAN SECTION N C- 4" LANE LINE OR 8 ;,� O CURB TURNING LANE LINE w 44 EXIST. C & G I THRU OR RIGHT 10' E.C.R. N 2TURN LANE Zo T_ _ » CASE 3 »R" N w 1 » ST 3 "R" CAB. - SECTION CAB 5' W 16Y2 g"UC— 61C 2 2" i•; SIDEWALK TOP OF CURB FACE 1 j �» » .►. VAI. RIES I ..� o + 0400-T0 O •V PLAN SECTION U Cd TYPE "R" CABINET FOUNDATION AND LOOP DETECTOR PLACEMENT POLE LOCATION CODI I.I.S.N.S. LEGEND DETAIL PAD DETAIL REFER TO PLAN FOR DISTANCE TO ADVANCE DETECTORS TO LOCATION BY ENGINEER IN THE FIELD) y3� i h 9 STEEELACAP " PLANS FOR THE CONSTRUCTION OF ARM LENGTH §EE " 608 24" TRAFFIC SIGNALS AND SAFETY LIGHTING AT SIGN TAB DETAIL AVE CARNELIAN STREET AND WILSON AVENUE �, �' SINGLE INPUT r EMERGENCY VEHICLE Name X X f Bono FOR PREEMPTION DETECTOR ARCHIBALD AVENUE AND BANYAN STREET $IGH WIRING NNECTORS (NIPPLE & _ OR s• BYO OTHERS) FOOTHILL BOULEVARD AND HELLMAN AVENUE OR r W-0" 1.5"TO.75" ASTRO Mini-Brac AB-0155-L OR NOTE: LB CONDULET, STO CABLE, HANGING REDUCER6TH STREET AND BUFFALO AVENUE HARDWARE & SIGN BY OTHERS AB-0132-L MOUNT OR ARM TUBE SIZE GENERAL NOTES APPROVED EQUAL LENGTH END O.D. x BASE O.D. x T11K. SIGNAL POLE 2 3/8" x 3 1/2- x 11 Gk SHW Steel of 48, psi minimum yield after fabricaUon MAST ARM ETIWANDA AVENUE AND ARROW ROUTE BASE PLATES W ONE WAY/ONE OUTPUT do FLANGES — e — e ( ) BACK CLAMP PIPE ASTM A-36--53Grode If Steel W/4 BOLTS MATE IAL SPECIF)CATICINS (AASTM A-307) BUTT WELDS lGroundus with se metall LONGITUDINAL All welds shall conform foAWS 01.1 weld SIGNAL POLE AT WELDS plecifacatiaSH i EMERGENCY VEHICLE DETECTORS 24• ABOVE FINISHED GRADE T ip galvanized per ASTY A-123 W ip galvanized per ASTY A-153WLSON AVE 5 • CLAMPSTRUCTURE n accordance with e "Specification or ur HARDWARE Supports of Highwayy Signs Luminares and BANYAN ST Traffic Signals AASHTO 194 WELDINGn accordance with the -Specification forStructural 1 210 FREEWAY 10 a 1 1/2" DIA. Supports of Highway Signs Luminares and DEEBBERNED Traffic Signals. AASHT0 1 94 8A5� LINE RNO NO. DESCRIPTION OF REVISION DATE APPROVED: SIGNAL POLE CLAMP W 4 DIA. HOLE IN 3• CLAMP SUPPLIED CITY OF RANCHO C U CAM O N GA Z; WITH A TYPE "F" (j ARM _ 3 —16UNC BLUNT CHURCH STREET + SCREWY PILOT HOLE RAD. (HOLD) POLE TRAFFIC SIGNAL PLAN TO BE FIELD AS REQ'D. FOOTHILL BO(MARO DRILLED) _ NOTCH OR DRILL 1" DIA. HOLE 3 RAD. ," ,• GENERAL INFORMATION AND DETAILS FOR DRAINAGE W/GROMMET 9 R—'i - INNFIELD DRILLED) DIA. ARROW STREET 5 CLAMP DETAIL DRILL SIGN TAB DETAIL PRpiES3/p4, GE Fq �F APPROVED BY: DATE: 6n♦ STREET y` o� RFs CITY ENGINEER RCE: 4953 fi:c Z HORIZONTAL IISNS MAST ARM 2z M DESIGN i=Ri:��k �� � RE MENDED °C RCE 048252 Kimtsy—Horn NOT TO SCALE * Exp, 8/30/06 yir SAL ��® and Associates, Ina. ®PROJECT INTERSECTIONS VICINITY MAP sr Civil �P DRAWN 1770 Iowa Xvenue Su4 20 SHEET ��• F SAL Rlvsrsid0. Galifomigk,925p1 2463' Q 2006 'l 8 (951) 78 '09OF 41 ��� e+ CHECKED 0 048252 DRAWING NO. Q DATE OJ/19/06 FILE N0 3 oa —�/ POLE SCHEDULE (SEE NOTE 1) CONSTRUCTION NOTES POLE DATA SIGNAL LUMINAIRE VEH SIG MTG PED SIG PPB EPB* I.I.S.N.S. LEGEND POLE LOC. REMARKS FURNISH AND INSTALL 8 PHASE NEMA CONTROLLER ASSEMBLY NTH DETECTOR No. TYPE Ht. M.A. M.A. HPS MAST POLE MTG 0 QUAD 0 QUAD (SEE NOTE 2) E B C F1 SENSORS 0 17 TELEPHONE MODEM AND AUXILIARY EQUIPMENT IN A TYPE "R" CABINET. REPLACE EXISTING RAMPS WITH CURB, GUTTER, AND SIDEWALK. PROPOSED HA DIAGRAM _ _ _ _ _ 8 1 —3-80 30 20 12 200W MAS SV-2-TA Wilson 8700 0 ' ' ' SEE PLAN 4.0 1, 2, 4 EXACT LOCATION TO BE DETERMINED BY THE ENGINEER. SEE SHEET 1 CABINET AND a CONSTRUCT CASE E WHEEL CHAIR RAMP PER CITY OF RANCHO PAD DETAIL. CUCAMONGA STANDARD PLAN 102. NOT NOT NOT 2 17-3-80 30151520OW MAS-46 SV-2-T SP-1—CS 6 S — — ST SEE PLAN 8.5' 1, 2, 3 Carnelian 5700 FURNISH AND INSTALL MODIFIED TYPE III-BF SERVICE WITH ONE 50A-I1? CIRCUITz USED USED USED BREAKER FOR METERED SIGNALS, ONE 30A-I1? CIRCUIT BREAKER FOR UNMETERED 10 INSTALL R3-4 SIGN ON MAST ARM. ?R O 3 17-3-80 30' 20' 15' 20OW MAS SV-1-T SP-1-CS 6 S - - AV -1.5' - 12.0 1, 2, 4 RELOCATE TO OR INSTALL SIGN ON EXISTING POST AS NOTED. LIGHTING ABD ONE 15A—IP CIRCUIT BREAKER FOR METERED I.I.S.N.S. PER STANDARD Wilson-- 8700 11 DRAWING NO. 407. 4 INSTALL 3" CONDUIT (±200') PER UTILITY COMPANY REQUIREMENTS. AT LEAST 48 12 RELOCATE TO OR INSTALL SIGN ON NEW POST AS NOTED. A ® 15 30 -' 12 200W — — SP-1—CS 8 W — — — — 6.0 3.0 1, 2 �3 HOURS ADVANCE NOTICE SHALL BE GIVEN TO SOUTHERN CALIFORNIA EDISON 13 REMOVE AND SALVAGE EXISTING SIGN AS NOTED. z NOT �O p 5 15 30' - 12' 20OW - - - 8 W - - ST 3.5 - 3.0' 1 Carnelian 5800 COMPANY BY CONTACTING ROB BOLTON AT (909) 930-8434. EXACT LOCATION OF ?E CONDUIT SHALL BE DETERMINED BY SCE IN THE FIELD. 14 REMOVE AND SALVAGE EXISTING SIGN AND POST AS NOTED. V © 15 30' - 12' 20OW - SV-1-T SP-1-CS - - - - - - 2.0' 3.0' 1 FURNISH AND INSTALL EVP DETECTOR ON MAST ARM PER DETAIL ON SHEET 1, WITH 15 INSTALL SIGN ON NEW TRAFFIC SIGNAL POLE AS NOTED WITH O7 PPPB B 7' - - - - - - 6 N - SEE PLAN 6.0' PHASES AS NOTED. MINIMUM 7 7'CLEARANCE TO GROUND. C ) POST) REMOVE ALL CONFUCTING STRIPING, PAVEMENT LEGENDS, AND PAVEMENT MARKINGS, EPB16 INSTALL 1200' OF 2" CONDUIT WITH PULLROPE TO TELEPHONE ® (7') PPB POST) 7' - - - - - -- 6 S - - 2.5 3.0' BY WET SANDBLAST. SERVICE POINT PER TELEPHONE COMPANY REQUIREMENTS. 1. ALL EQUIPMENT NEW INSTALL 12" WHITE CROSSWALK NTH 10' BETWEEN PARALLEL LINES. 17 FURNISH AND INSTALL SURFACE MOUNT WEATHERPROOF NEMA 2. INSTALL IISNS ON HORIZONTAL ARM PER DETAIL ON SHEET 1. ENCLOSURE ON SIDE OF THE CONTROLLER CABINET FOR INSTALL PAVEMENT LEGENDS AND MARKINGS AS NOTED (PER CITY OF RANCHO INTERCONNECT AND TELEPHONE ACCESS (PER CITY OF 3. MOUNT LUMINAIRE ARM 90' CCW FROM TRAFFIC SIGNAL MAST ARM. CUCAMONGA STANDARD PLAN 133). RANCHO CUCAMONGA STANDARD PLAN 408). J 4. IISNS ARROWS SHALL POINT EASTERLY I v POST TOP MOUNTED EQUESTRIAN PUSH BUTTON II Q� II 225' TAPER AT 45:1 EXIST SIGN R2-1(45) EXIST TREE18 I I TO REMAIN R/W EXIST SIGN R1-1 I I EXIST SIGN 14 S1-1, W16-7p(TYP) I I CARNELIAN W2-2(L) R9-3a 15 9 S TRE E l " -T 1 0 2 1 c, 1-aLc �' _ rl fit l I O � 40' � 32' 6 DIRT _ N DIRT DIRT ,rte - - - - �-�, �� C� - - -� r - - - - - - -, - - - -- — - — - — -- - - - - - - - - - - - � / I \ 1 I - 1 _ /Z-------------- I I 4 1 \ ���-\ - - - - - - 7 (50 LF) SIDEWALK T- - - - - - - - - - - - - - - - - - - - - - - �' - - - - - - - - - - -��- - - - - - -""'- _ _ - I 06P -C=-B'- -� - - - — -�- - - - - - - - - - - - - - - - - - - - - - - - - - - - _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ " - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - DLC R9-3a 15 06 10 0 4 09 , 2-N-04 G G G G -� G G --------- G -- G - G G 110 EVO >a8 06 I 50' 50' EXIST STREET NAME SIGN 7 450' TO N 7 (100 LF) !�s 5 (230 LF) 7 BY EDISON RS 2 4 EVPlift. \� 10 ' LIMIT LINE 4 SE f DETAIL "A" 3-N-m4 o s - - - - - - a knw `� v 30' TO 30 `� 7 12" WF ITE , Q 50 00 � 2- - 10 CL 6 - _ "0'8 MIT LINE �_ 1 3 W� W� 0 1— 08P�r 15 R9-3a 0 4, ' , 7 TYPE IV (L) 7 (150 LF) ,r - ° 7 TYPE IV (L) ,r W W r� � W W 1-7 ��� � \ EV ; � T�✓ W - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � - - - - - - - - - - —_ —_ - - - -1- - 6 10 CLR 10 , I -- - - - - - - - - - - - - - - - - - - - - _- 'T- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -� `� /ice 1 - �� ii � � ��- � - r� C3 ox aH off ox L �+ { off—DIRT—T= aH aH off c o aH \ 5 Lim ;— —E$;— _ . --'a+ —T.{-1 °" `— �+ G -cr \\ -------------- i — — — — — — — — — — — — — — - 089 — — — — — 1 I I I 71 - - - - - - - - - - - _ _ _ SI E A _ _ _— I o - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — — iil� i �6r �— �� %- - - - - - - ��--� — — — — — 7 \� n; n,' �/ DIRT 7 6E \� i 7 ' „ �� ; O3 15 STREET NAME SIGN 7 (50 LF) 11 )IVI 1 " O / _ _ C 1-DLC _ 1 �� 1 o I I I I / - - � 1YZ"C, 1-DLC 2"C., 2—#12 (IISNS), 6 5 5 I ' I I ;; � \ I I \, 4 3 - - - - - - - -- W3-3 12 I I I I l " 2—#10 LUMINAIRE) I I 1 I I 9 L3 I I I I 2-C., 3—#6 (SI&A SERVICE) 9 IT I I 4 I ►� i I I I I I I I I EXIST STREET NAME SIGN 11 W3-3 1\4 R1-1 I I I I I EDISON POWER POLE 8 I I I 13 W11-7,S1-1 #H30306Y I I I I I w \ I 1 I I I I 1 7 TYPE IV (R) II II EXIST SIGN R26(S)(CA) I I I I I I 7 TY E IV (L) Red 12" II II I I I I 1 I I III \I\ %"C, 1 DLC � I I I I I I 7 I I i I I I 7 (100 L Yellow 12" I I I I 1 I I I 15' 1 12' 1 ' 12' "p, I I t— I I I I I 11 I l Green0 12" II II l l I 3 ' o SIMULTANEOUS I I I I I w l l w I I I Green 12" Ile) I I I Arrow II II 1 1 I(260 UTZ ,� I.,N� FZ,I I I I 1 1 / DETAIL „A» 1 I I I I I I fi I I I I (No Scale) 4k ' } EXIST SIGN R61— 9(CA) Q�_ • I I I 5 a CONDUIT RUNS 1 1 I POLE AWG CIRCUIT i II I I I DETECTOR SCHEDULE 1 2 3 4 5 6 7 I I I I I 7 TYPE IV (R) SENSOR DETECTOR CONTROLLER LOOPS PER 1 W 04,06 N0. CHANNEL INPUT CHANNEL 2 m 06,08,06P,06PPB,06EP8 1 - - - - - - B DETECTOR RACK 1 v MATCH UNE "B" - SHEET A RIGHT � 0 3 08,08P,06PP6 — 1 1 1 1 1 E 1 1 UNUSED 3 - DETECTOR RACK 2 _ a _ _ _ am 2 1-N-�4 4 1 1 1 UNUSED 19 4 0 06P,08PPB - - - 1 1 1 1 N0. DESCRIPTION OF REVISION DATE APPROVED. (3 2 1 UNUSED 1 - 2 3-N-04 20 1 5 �8PP6 - - - - 1 2 UNUSED 2 - 2 1 UNUSED 17 6 z �4,�SP _ _ _ _ _ _ _ _ _ _ CITY OF RANCHO CUCAMONGA 05 3 1 UNUSED 7 - 2 UNUSED 18 _ _ _ _ - _ _ _ _ 1 2 1-5—o8 8 1 3 1 UNUSED 23 7 0U 06EPB(CONNECT BICYCLE INPUT) _— _ 1 _ _ - TRAFFIC SIG NAL PLAN 4 1 UNUSED 5 — 2 UNUSED 24 _ 8 ) 06EPB(CONNECT BICYCLE INPUT) 1 — 2 1-E-06 6 2 4 1 UNUSED 21 N TOTAL 4 7 7 5 1 UNUSED 11 - 2 3-E-06 22 #10 SAFETY LIGHTING 2 2 2 2 2 2 - CARNELIAN STREET AND 2 2-N-04 12 2 5 1 UNUSED 27 6 1 UNUSED 9 - 2 4-N-04 28 3 TYPE "C" 4 LOOP LEAD-IN 4 4 = - - 4 4 WILSON AVENUE 2 UNUSED 10 - 6 1 UNUSED 25 - DLC = g 4 4 4 4 Y 7 1 UNUSED 15 - Z UNUSED 26 - (1. 8 _ _ _ _ _ 1 2 PROFESS/pN�` " 2 2-5-08 16 2 7 1 UNUSED 31 - TOTAL 4 4 - 4 4 9 10 :F � �GE Fq� Fy APPROVED BY: DATE: 1 UNUSED 13 - 2 UNUSED 32 - ,..<, y �O Fs, i CITY ENGINEER RCE: 24953 , 8 2 2—E-�6 14 2 1 UNUSED 29 — I.I.S.N.S. 12AWG 2 2 2 2 2 2 — V rn DESIGN FLAN PREPARE', BY RECOMMENDED Under round Service Alert _ 8 1 2 1 1 1 3 3 or RCE 048252 Y 9* 1 EVP 06 EVP 3 2 4—E-06 30 3 EMERGENCY VEHICLE PREEMPTION _ — _ _ — _ _ 20 10 0 20 40 * Exp. 6�30�06 * JAR CON! '°`g as. ino. 2 UNUSED EVP 4 — INTERCONNECT CABLE DRAWN SHEET a Call: TOLL FREE ,n0 Iowa Avenu% Suits 200 v * 1 EVP 08 EVP 5 CONDUIT SIZE -2 3" 2" 3" 3" 4" 4" " `�'� CIVIL �°' JAR Riversid0. Calitarnio 92507-2463 Q 2008 2 8 1-800 10 2 EVP 04 EVP 6 OF 227-2600 1 �'2� t �'�F��i��"SCALE � � CHECKED DRAWING N0. * • ALL CONDUIT AND CONDUCTORS NEW ��,� `951' 782 4t R.C.E. NO x48252 _-- �+ EVP DISCRIMINATOR DATE FILE No 94t `300(0 -J M wor�ciNo 4AYs et�-or�You D10 05/�9/Dd CONSTRUCTION NOTES MATCH UNE "B" — SHEET A BOTTOM r8r FURNISH AND INSTALL 8 PHASE NEMA CONTROLLER ASSEMBLY WITH DETECTOR SENSORS — AUXILIARY EQUIPMENT IN A TYPE "R" CABINET. EXACT LOCATION TO BE ❑ REPLACE EXISTING RAMPS WITH CURB, GUTTER AND SIDEWALK. 1 I I i I I 7 TYPE IV (L) DETERMINED BY THE ENGINEER. SEE SHEET 1 CABINET AND PAD DETAIL. [i] CONSTRUCT CASE E WHEEL CHAIR RAMP PER CALTRANS I I I 3 1I I FURNISH AND INSTALL MODIFIED TYPE III—BF SERVICE WITH ONE 50A—IP CIRCUIT STANDARD PLAN DETAIL A88. I DBREAKER FOR METERED SIGNALS, ONE 30A—IP CIRCUIT BREAKER FOR UNMETERED I I I I I LIGHTING ABD ONE 15A—IP CIRCUIT BREAKER FOR METERED I.I.S.N.S. PER STANDARD 10 INSTALL R3-4 SIGN ON MAST ARM. DRAWING N0. 407. 1, INSTALL SIGN ON EXISTING POST AS NOTED. INSTALL 3" CONDUIT PER UTILITY COMPANY REQUIREMENTS. AT LEAST 48 HOURS 12 RELOCATE TO OR INSTALL SIGN ON NEW POST AS NOTED. I I I I I I n3 ADVANCE NOTICE SHALL BE GIVEN TO SOUTHERN CALIFORNIA EDISON COMPANY BY I I I I I ( 13 REMOVE AND SALVAGE EXISTING SIGN AS NOTED. If EXIST SIGN OMNITRANS ROUTE INFO I I I I I CONTACTING ROB BOLTON AT 909) 930-8434. EXACT LOCATION OF CONDUIT SHALL BE DETERMINED BY SCE IN THE FIELD. REMOVE AND SALVAGE EXISTING SIGN AND POST AS NOTED. I— 11 15' 12' 1 12' i5' I ❑ I FURNISH AND INSTALL EVP DETECTOR ON MAST ARM PER DETAIL ON SHEET 1, WITH 14 I I I I I W I PHASES AS NOTED. 15 INSTALL SIGN ON NEW TRAFFIC SIGNAL POLE AS NOTED WITH I I I i II I ❑ ❑ I I I I I REMOVE ALL CONFLICTING STRIPING, PAVEMENT LEGENDS, AND PAVEMENT MARKINGS, BY MINIMUM 7 CLEARANCE TO GROUND. 1 I 1 I I 7 (160 LF) WET SANDBLAST. I I I I I I I ❑5 INSTALL 12 WHITE CROSSWALK WITH 10 BETWEEN PARALLEL LINES. I I I I I I I I I I II 1 7 (260 LF) 7 INSTALL PAVEMENT LEGENDS AND MARKINGS AS NOTED (PER CITY OF RANCHO I I I I 3 I CUCAMONGA'S STANDARD PLAN 133). I I I I I I II I I I I I I I I W I (260 LF) 7 1 1 1 P I I I I nt I nt I i1 1 I I I Ur I U� I I I I I I I EXIST SIGN OMNITRANS ROUTE INFO I I I I I 3 I I I I I I I I L; I I I I I I I I I It I II I EXIST SIGN R26(S)(CA) I I R1—/W— — —N— — ——---- -W1-1--7—G,S—1--1 —13— - - - - CARNELIAN — — S TREE— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ifZo - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - IN at at at at at a, o -�, I I I I ;; I I I I 12 R61-19(CA) DIRT N 1 I I I I I I I I I I I I I ii ii I Dt 11 1 I I I II II I I I R/W 7 (226 LF) I I I I I I I I I I ii ii I I I I I I I I ii ii I I I I I R/W EXIST SIGN W11-7,S1-1 R/W I I I I I I ii ii I I I 225 TAPER AT 45:1 I I I 3 I if I I I I ii ii I I I I O I I I I ii ii I I I I I I I ii ii I I I I � V) _ I II 11 it II I i w II "' 11 II t EXIST SIGN R26(S)(CA) II EXIST SIGN R26(S)(CA) 1 I I I X11 I I I u►I I I �t►I I I I I I �� a I I I iNi 3 I I I I I I nl 11 I 1 I II 15 �Tnn 1) n I y �,J ) I I I I 1 1 ►, ii I j1 I j1 I I I � I if i ►I I I I `� CITY t I I i I 7 I I I 13 NO. DESCRIPTION OF REVISION DATE W3-1 APPROVED: W3-3 CITY OF RANCHO CUCAMONGA 5 '1 '1 32' 32' ",01 I TRAFFIC SIGNAL PLAN ' ' CARNELIAN STREET AND WILSON AVENUE PEtOFES$�ON APPROVED BY: r DATE: GE Fe. �F CITY ENGINEER RCE: 24953 DESIGN F'LAh PREPARED by RECOMMENDED k& Underground Service Alert --Han rn JARKtmteyy RCE 048282sso }�� Y rm ,-Mn and Acka tea, in e. TOLL FREE 20 10 0 20 40 DRAWN SHEET * Exp. 8/30/06 >k 1770 Iowa Avenue. Suits 200 1-800 CIViIi- JAR 3 OF 8 Riverside. California 92507-2465 C 2003 19 - 227-2600 " ' � t�P CHECKED (sst) 792-094t OR N0. 1 =20 GRAPHIC SCALE OF CptL' R.C.E. NO-Z=O �OO�_� TWO WORKIN{DAYS AFORE Ye.! DI{ DATE 19�� FILE NO Nil CONSTRUCTION NOTES 7IPOLE SCHEDULE (� NOTE 1) a FURNISH AND INSTALL 8 PHASE NEMA CONTROLLER ASSEMBLY WITH DETECTOR SENSORS, TELEPHONE MODEM AND '�t I II POLE DATA SIGNAL LUMINAIRE VEH SIG MTG PED SIG PPB I.I. POLE LOC.AUXILIARY EQUIPMENT IN A TYPE "R" CABINET. EXACT LOCATION TO BE DETERMINED BY THE ENGINEER. SEE No. TYPE Ht. M.A. M.A. HPS MAST POLE MTG 0 QUAD (SEE NOTE 2) E B CREMARKS SHEET 1 CABINET AND PAD DETAIL. W3-3 13 .i I 1 Ql 17-3-80 30' 20' 12' 20OW MAS-4B SV-1—T P-1—C 4 E AV 6.5' — 6.0' 2 '� I Archibald 6000 ❑ FURNISH AND INSTALL MODIFIED TYPE III—BF SERVICE WITH ONE 5OA—IP CIRCUIT BREAKER FOR METERED SIGNALS, ;I; I I TWO 30A—IP CIRCUIT BREAKERS FOR UNMETERED LIGHTING AND ONE 15A—IP CIRCUIT BREAKER FOR METERED p II �� II Q 15 30' — 15' 20OW — SV-1—T SP-1—CS 6 S — — —1.0' 3.0' — PER STANDARD DRAWING NO. 407. �- an ❑ INSTALL 3" CONDUIT (±200') PER UTILITY COMPANY REQUIREMENTS. AT LEAST 48 HOURS ADVANCE NOTICE SHALL p ;' Q 26-4-80 30' 45' 15 200W MAS-5A SV-1-T SP-1-CS 6 S Banyan s 00 --0.5' - 3.0' 2 BE GIVEN TO SOUTHERN CALIFORNIA EDISON COMPANY BY CONTACTING ROB BOLTON AT (909) 930-8434. EXACT M 6 I-?, � I I� y LOCATION OF CONDUIT SHALL BE DETERMINED BY SCE IN THE FIELD. I ( I' I I ® 15 30' - 12' 20OW - SV-2-T SP-1-CS 8 W - - 5.0' 3.0' - ❑4 FURNISH AND INSTALL EVP DETECTOR ON MAST ARM PER DETAIL ON SHEET 1, WITH PHASES AS NOTED. 1}�2"C, 1-DLC 1-W-�5 3, Ilr— I I _ _ _ - _ _ _ FF 1: I I 05 1—A 10' TV-1—T P-1—C 8 W 1.5' 3.0' ❑ REMOVE ALL CONFLICTING STRIPING, PAVEMENT LEGENDS, AND PAVEMENT MARKINGS, BY WET SANDBLAST. r j �� , — — © 15 30 15 20OW SV-2—TA — — — AV — —27.5 3.0 2,3 Archibald s�oo ❑6 INSTALL 12" WHITE CROSSWALK OR LIMIT LINE. ❑7 INSTALL PAVEMENT LEGENDS AND MARKINGS AS NOTED (PER CITY OF RANCHO CUCAMONGA STANDARD PLAN 133). II c� II 07 24-4-80 30' 35' 15' 20OW MAS-5A SV-1-T SP-1-CS - - Banyan shoo 10.0' - 3.0' 2 , ❑8 NOT USED. R3-7 13 I j j 40 I� I I ® 15 30' — 12' 200W — SV-1—T — 4 E — — 15.0' 3.0' — I, I I D9 CONSTRUCT CASE E WHEEL CHAIR RAMP PER CITY OF RANCHO CUCAMONGA STANDARD PLAN 102. II ii II 1. ALL EQUIPMENT NEW TYPE IV (R)1a__ 2. INSTALL IISNS ON HORIZONTAL ARM PER DETAIL ON SHEET 1. 3 II PROPOSED PHA: DIAGRAM 10 INSTALL R3-4 SIGN ON MAST ARM OR POLE. 111 I ;; I I /W GROUP GROUP TYPE VII (L 7 ' 111 3. IISNS SHALL BE ONE—SIDED WITH OPAQUE PANEL TO THE EAST. 11 NOT USED. II ul ;; II NOT NOT 12 RELOCATE TO OR INSTALL SIGN ON EXISTING POST AS NOTED. R/W I 11�< ii c� II USED USED 11 11 ❑13 RELOCATE TO OR INSTALL SIGN ON NEW POST AS NOTED. (100 LF) 7 I i ;; I I EXIST R2-1(35), �* — II III II D11-102 03 4 I I I, I 14 R AN SALVAGEEXISTING SIGN AS NOTED. I I I i i � I Q ❑15 REMOVE AND SALVAGE EXISTING SIGN AN II II I v I G S G D POST AS NOTED. � I I �� I z TYPE IV (R 7 7 ( ) 16 INSTALL R9-3a SIGN ON SIGNAL POLE 7 FEET ABOVE FINISHED GRADE. �� i I VII L 0 17 CONTRACTOR TO REQUEST AND COORDINATE THE REMOVAL AND SALVAGE OF EXISTING STREET LIGHT WITH SOUTHERN (J) _ j j111 `n I I * PROTECTED—PERMISSIVE LEFT TURN—WIRE CABINET CALIFORNIA EDISON. R1 115 II a it ( II s FOR ASSURED ANTI—BACKUP TO 03 AND 07 I 3 3 ii II 18 FURNISH AND INSTALL SURFACE MOUNT WEATHERPROOF NEMA ENCLOSURE ON SIDE OF THE CONTROLLER CABINET FOR 17 I I ,I II INTERCONNECT AND TELEPHONE ACCESS (PER CITY OF RANCHO CUCAMONGA STANDARD PLAN 408). CR=35' cv i i I 11,31 500' TO ❑19 " I 8 s I ( x" ,I = CROSSWALK INSTALL ±200 OF 2 CONDUIT WITH PULLROPE TO TELEPHONE SERVICE POINT PER TELEPHONE COMPANY REQUIREMENTS. t I I 't A VENUE .. 119 CR=20' 1Yz"C, 1-DLC EXIST D11-1 1J� C, 1-DLC W2-1 ARCHIBALD R/W 15 � O R/W 16 /, " I, I 3 „ d {�� °"� 4P`�i�� 06 �n11";� ii 4P 3 17 00 ,�� 13 W3-3 ON off �---- + a,.94 „ o, Pr f-�— or+ L —°" �,+ or, off ori or, or off L� {,J -- a+ ai ori c - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - M- - - <, - - - - I 10 6 9 1 03& - - - - - - - - - - N - - - - - - - - - - - - - - - 7-(100 LF) - - - - - - - - - - - - - - - - - A`.- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ _ _ 17 10 CLR 6 5 6 E 08 50' -� - s _ s - - - - s - - - - - - -� - - - s - - - 4 s R10-12 SEE EAI "A" I I , z 7 c - c c- c c c TYP 19 _ 4 �4 c VP G- ------------- N ------_ _ - ------_--_---------_ ____________________ _____________________________________ ___ (t} -- - --___- _ - _-------- , I --- -y-- -------------------------------------------- 0 CL 6 -- � ------------------------- ----- 260 TO _] - - ------- -- - -------- ----------- 4&07� ----------- -- ------ 450' TO 230 TO - . , 5 I LIMIT LIN LIMIT LINE 1-S- --Sx--- 0 5x 2-S-03 5x - x ----- :; -- 5x 5x o - - - CR OSSWALK - - - - - N - _ � / 2-N-07 1 N �7 ---------- -------- 5x6 _ ---- - --- ---- ----------- - - - - z ------------------- -- -- ---------------------- -- _ 1 -- --------___________-_--------------------------------------------- ----- ------------------- -----=_____--------------------------------- ------------- -------- -------------- - - ---------------------------- v+ _ �? 6 V) - - - - - - - 00 N 45' I �8 EVP 4 - 10 - - - - - - - - - - - - - - - - - - o - - - - - - - - - - - - - - - - - - 7 - - - �_ w �-- w- w �' w (TOG-0)F7 c�•� w SEE DETAIL A VP 8 A w w � w w w w w w w w b 1 4 50' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ------------------------- o 16 �4&�7 5 = 2"C., 2-#12/(IISNS), m ____- ____- -_____, _- - - ��� - - - -_ - - -_ - _ - - i _ 10 (SAFETY LTG) in �3 ,- OH ----------- --- ----------------------- - -r " -------- ----- - - - - - - - - R/W )1V A, ------------- - - - - - - - - - - - -- - ----------- 5� CR= 0 0 L W3-3 13 - - - - - - .-- - �. I II 6x 1 C, 1-DLC 5 I I I� -- 1h-C, 1-DLC I I 6 I EXIST W4-1a 7 3 0 CONDUCTOR SCHEDULE '* I i 11 __ . _` - - CR-20' 2 3 R/W N CONDUIT UN i i , I �6 1 2"C., 2-#6 0 POLE AWG CIRCUIT 1 2 3 4 5 6 7 8 O o 1 J 06,06P/04PPB - - — — — — — — — — j I I i' I I 9 2 co 03,08,04P/06PPB — — — — — — — — — i N I i 15 V) 3 03,08,08P/06PPB — — — — — — — — — — — 1 I I I� I I 4 AM C 05,06,06P/08PPB — — — — — — — — — — — — 1 ; I I I i 15 EXIST R1-1,W4-4P '�- 5 05,08P/08PP8 — — — — — — — — — — 1 I I I I DETECTOR SCHEDULE DETECTOR RACK 2 20 10 0 20 40 6 04,05,07/ — — — — — — — — — — — — + I ;, j j 19 SENSOR DETECTOR CONTOLLER LOOPS PER 1 UNUSED 19 — v 7 04,07,04P/ 13 I I N0. CHANNEL INPUT CHANNEL 1 1"=20' GRAPHIC SCALE Red II II 2 UNUSED 20 — 3 06 �4PPB — — — — — — — " I , EXIST o N / 12 I0II I, MAILBOX DETECTOR RACK #1 1 UNUSED 17 — j _ v TOTAL — 1 — ` I j j 1 1 1—S-03 3 1 2 2 UNUSED 18 0 #10 SAFETY LIGHTING 2 2 2 2 2 2 2 — I I Yellow0 12 I I i 2 1—N-04 4 2 1 UNUSED 23 — 1= TYPE "C" 1 LOOP LEAD—IN — — — — — — — — I j j 1 UNUSED 1 — 3 2 UNUSED 24 — DLC 2 — — — — — — — — Green 12" I 1 i' I I \\ �� 2 2 UNUSED 2 — 4 1 3—W-05 21 1 0 3 — — — — 2 2 2 2 0I I I I z 1 1—N-07 7 1 2 UNUSED 22 — am 4 — — — 2 — — — 2 Yellow I I I I / \ 3 NO. DESCRIPTION OF REVISION DATE APPROVED: v Q I 2 1—S-08 8 2 5 1 UNUSED 27 — 2 5 — 4 4 4 — — — 4 Arrow (9 -12 I II / \ 6 - - - - - - 2 2 1 2 II,/J1 11_\ 4 , 1—W-05 5 , 2 UNUSED 28 - CITY OF RANCHO CUCAMONGA o 7 — — — 2 — — — 2 Green ,2" 4, I + 0 I I 2 1—E—o6 6 1 6 1 UNUSED 25 0 Arrow I i 1 I 5 1 2—S-03 11 3 2 UNUSED 26 — M a 2 2 2 2 3 11 TRAFFIC SIGNAL PLAN 1 40' 2 2—N-04 12 4 1 UNUSED 31 — TOTAL — 4 4 8 4 4 6 14 „ „ 1 i 1 1 1 UNUSED 9 — 7 2 UNUSED 32 — p I.I.S.N.S. 12AWG 2 2 2 2 2 2 2 - DETAIL A I p Q 6 2 UNUSED 10 — 1 4—W—�5 29 3 ARCH I BALD AVENUE AN D EMERGENCY VEHICLE PRE—EMPTION 1 1 2 2 — 1 1 4 (No Scale) � N 1 2—N-07 15 3 a 2 UNUSED 30 - BANYAN STREET INTERCONNECT CABLE — — — — — — — — I " " - 1 " " '• 312 - ! I I I P 7 2 2—S-08 16 4 OFESs Y CONDUIT SIZE 2 3 2 / 4 2 3 / 31/ I c�3 PR io v I I I 8 1 2—W-05 13 2 GE F14 ti��� APPROVED BY: DATE:5/72 • ALL CONDUIT AND CONDUCTORS ARE NEW I I II 2 2-E-06 14 3 y` o4 R<"s,yp CITY ENGINEER RCE: 24953 Underground Service Alert I I lit 9* 1 EVP 06 EVP 3 - � DESIGN �t.�r� f'REP�IREQ BY: RECO MENDED I RCE 048252 is Ham � �: EVP 05 EVP 4 — SAL 8/30/06 ® � d ssocates, Inc. O ' , 0 SHEET Or * 1 EVP 08 EVP 5 - — ,��� -: �- 1770 IOWA AVENUE, SUITE 200 N Call: TOLL FREE l i I I DRAWN 1-800 I I 13 W3-3 10 ,N � s`r CIVIL .P SAL 4 OF 8 "`� 227-2600 7 I I 1 2 EVP 04 EVP 6 +� RIVERSIDE. CAUf�2NIA 92507 c zoos III I I a` CAL ��� (s5,) 782- 41 0� * - EVP DISCRIMINATOR CHECKED R.C.E. No_ Z DRAWING TWD WORKING DAYS BEFOK YOU DIG 33 DATE FILE NO CONSTRUCTION NOTES 1 EXISTING TYPE 170(E) CONTROLLER IN TYPE 332 CABINET TO BE RE-USED. ADD 17 REPLACE EXISTING STREET NAME SIGN WITH I.I.S.N.S. 1i ii� I II i POLE SCHEDULE DETECTOR SENSORS, LOAD SWITCHES AND ALL OTHER APPURTENANCES REQUIRED MOUNTED PER DETAIL ON TITLE SHEET. _ POLE DATA SIGNAL LUMINAIRE VEH SIG MTG PED SIG PPB •I• POLE LOC. TO PROVIDE THE OPERATION SHOWN ON THIS PLAN. w3 3 12 I I ii i No. I TYPE Ht. M.A. M.A. HPS MAST POLE MTG 0 QUAD (SEE NOTE 1) E B C REMARKS 0 t8 CONSTRUCT CASE C WHEEL CHAIR RAMP PER DETAIL C (SEE o � 1 I I ;; I 01 26-4-80 (E) 30' 45'(E) 12'(E) 20OW(E) 2—MASE) SV-1—T(N) SP-1—CS(N) 08 E AVE 4.5' — 3.5' 1 EXISTING TYPE III-CF SERVICE TO BE REUSED. CITY OF RANCHO CUCAMONGA STANDARD PLAN 102). 3 II (N) Hellman 8o00 3REMOVE AND SALVAGE EXISTING PEDESTRIAN INDICATION. NOT USED 19 FURNISH AND INSTALL NEW INDICATION PER SPECIAL o �� I I O2 1-A (E) 10' - - - - TV-2-T(N) SP-1-CS(N) �2 S - - 12.8' 2.0' a4 FURNISH AND INSTALL EVP DETECTOR ON MAST ARM PER DETAIL ON SHEET 1 PROVISIONS, ORIENTED AS SHOWN. 1 �� I WITH PHASES AS NOTED III 17-2-80 30' 20' 12' 20OW(R) MAS SV-1—T SP-1—CS(N) 02 S 33VO 5.5' — 4.2' 1 20 ABANDON OR REPLACE EXISTING CONDUIT PER CONDUCTOR � II r}"--J II I I i (N) Foothill 9300 � SCHEDULE.REMOVE ALL CONFLICTING STRIPING, PAVEMENT LEGENDS, AND PAVEMENT II ® 1—A (E) 10' — — — — TV-1—T(E) SP-1—CS(N) 04 W - - 13.6' 2.0' MARKINGS, BY WET SANDBLAST. �6 INSTALL 12" WHITE CROSSWALK WITH 10' BETWEEN PARALLEL LINES. ; ; ±'� I i I 05 26-4-80 (E) 30' 45,(E) - - 2-MASE) SV-1—T(N) SP-1—CS(N) 04 W (N) Hellman 8100 13.7' - 2.0' 1 1 7 INSTALL PAVEMENT LEGENDS AND MARKINGS AS NOTED (PER CITY OF RANCHO R/w 1-A (E) 10' - 12'(E) 20OW(E) - TV-2-T(N) SP-1-CS(N) 06 N - - 12.8' 2.0 - CUCAMONGA STANDARD PLAN 133). SP `i I i i ;; I I J XIST R2-1 40 @ 24-4-80 (N) 30' 35'(N) 12'(N 20OW(R) MAS-5A(N) SV-1-T(N) SP-1-CS(N) - - e () 18.0' - 2.0 1 D8 REPLACE EXISTING RAMPS WITH CURB, GUTTER, AND SIDEWALK. EXIST 2"C, 2#6 I I I ( ) (N) Foothill 9200 SERVICE I 11� ______��--- I I 8 PPB POST N - - _ _ 06(N) S - - 18.6' 4.5' 1�1CONSTRUCT CASE E WHEEL CHAIR RAMP PER CALTRANS C' I I - ; 111' O 3.5 08 N E STANDARD PLAN DETAIL A88. 13II 22' i 111 18' II 13' y 09 1—A (E) 10' — — — — TV-1—T(E) SP-1—CS(N) — — — — 12.9' 3.0' — 10 INSTALL R3-4 SIGN ON MAST ARM. I1 ' 66' I I t INSTALL SIGN ON EXISTING POST AS NOTED. EXIST 1}2"C, i ;; 1 R/W 1. INSTALL IISNS ON HORIZONTAL ARM PER DETAIL ON SHEET 1. 11 I I I ' ' ' " 1 EXISTING TO REMAIN PROPOSED PHASE DIAGRAM 3-DLC I II 14 ;, 10 II 16 II (E) GROUP GROUP 12 RELOCATE TO OR INSTALL SIGN ON NEW POST AS NOTED. ` --;-- I I I I I N NEW EQUIPMENT OR POLE II ( ) _ Q RS I II I _ II REMOVE AND SALVAGE EXISTING SIGN AS NOTED. I _ '_ I I ; - I I I -p 13 r - INSTALL I I (R) RELOCATE EQUIPMENT TO NEW POLE OR POLE TO NEW LOCATION v * I _ II 14 REMOVE AND SALVAGE EXISTING SIGN AND POST AS NOTED. CB ' ; I IR10-12` " I I a _ 1 1 I , ' I I I 171ST R5-2 15 INSTALL R9 3a SIGN ON SIGNAL POLE 7 FEET ABOVE r'' I I = , I I I I I 1 4 FINISHED GRADE. 3 1-1 1 r'_ t 1 r ii I ( 19 4 16 UPGRADE YELLOW AND GREEN TO 12" LED INDICATIONS SEE DETAIL �B" 18 O I -=J ;� , ii 10 I I z I USING 12» LED LAMPS. 20 FO O THIL - kr I ' : , 3 BOULL VAI iiD �- R W EXIST FIRE 2 / �� n / EXIST MAILBOX CONNECTION 1 DEPARTMENT CB O T,`I 11 1 Y1 P 18 SEE DETAIL "C" * PROTECTED—PERMISSIVE LEFT TURN 12 W3-3 :. L--J -_ 8�� EXIST 1Xi"C, - - v -I - _ _ - EXIST R6-2 1-DLCR yy E E E F E r r r 2 `� ,/- �4 2 AL 1'�4\ �' 2P ® EXIST 1-C, 1-DLC / EXIST D3 I c] N 07 19 0 04&0 ��- - - - - - - - - - - - - - - - -r- - — - - - - - - - - - - - - - - -'—'- - - - - -`3'- - - - — — — — — — — — — — 4 6 I EVP 7C 4_ - - - - - - - - ';`i in w EXIST 2"C 1 8 1 � L DE'TAIL A --aEE -' —L==== _j ---===='z ____�_____ _ -_ - - - - - - -__ 1 � W/SIC 19 RS 5 6 6 5 19 L �'� ��` EXIST 2"C ; o i -�'----- __T__, W/SIC ; G G G- G G G C G -� r'r'r-;---�- -- G r G - }—� G J- G G fi G J-� 1 16 - - - - - - - - - - - - - - - - - - - - - - EXISTING - - - - - - - - - - - 7 - - - - - - `-�- Q RAISED MEDIAN --- { 02 1 N - - - - - - - - - - 250' TO In cV EXIST 1}�2"C, W SIC 120 ��<- N `� ' 2&05 EVP , ' ' ' ' ' 7 (100 LF) `` ' /-EXIST 1Yz"C W/SIC _T-- CROSSWALK TO VINEYARD VE L ' L J L J N TO ARCHIBALD AVE L --- ------------------------------------------------------------ --- ----------------------------------------- ------------- ---_--_------ ------- -- - -- -- -- 7 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -�- - - - - - - - - - --- -------------- ------------------Z-�-----------------------'---------------------- __-------- ----- ---------- .: 1 I I � . I I ' EXIST R4 7 . s - J ' �� J - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - R4-7a - _ -- -- -- _, - - - - - - - - - - - ao � ' ' I I r '�. 71' � � `}" � tel- � I XIST 50' --- ------------------------------------------------------------ is T =' �5 I I �. 1 1 0) 1 I I I � . 400 TO N lj-- -- L;-_J u� CRAISED ,, --------- ^� — r--� — i �--- —r-- '^ — — — — — --- ------ - - - - - MEDIAN _ CROSSWALK --- - - - - - - - - - - - - - - - — 111Ui 11 119U i i i i ,_ i — — - -------- j T — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — - --- ------------------------------------------------------------ ---X--------------------- - `�!- —, — — — — — — — — - -�- -------------------------------------------------------- - ---4--------------------------------------------------------------------------------------------------------------------------- --- ----------------------- ---------------- r --------------- i I _ -- I '04 --� I --� i ► 6 ; v, 1 1 �. I I 1 1 I N O 3 N - - - ' - - -L--{ } --J I �- -J 01&06 EVP I - - - - - - - - - - - - - - - - - - - - - '�� - - - - - - - - - - - - 71 1 -�� 1 -� c0 r--� , ``. 191 r---1 ; , r --i �6 — " � i ii 7 `� 11 , -- �1 `� N L--�; i j---� ; ' __j AB I 16 I o �—, — ,r 1 C, 2 DLC19 C14 1 C, 2 DLC g ; ,�w �,-A w w w w ',� ��;.� t� � W - �3 & v 17 r� _ w �v A` w w w ===g0=== 275' TO POLE SCHEDULE SEE NOTE 1 CROSSWALK POLE DATA SIGNAL LUMINAIRE VEH SIG MTG PED SIG PPB I.I. . LEGEND POLE LOC. REMARKS12 W3-3 No. TYPE Ht. M.A. M.A. I HPS MAST POLE MTG 0 QUAD (SEE NOTE 2) A B C PROPOSED PHASE OIAg2AM GROUP GROUP Q 29-5-80 30' 55' 15' 20OW MAS SV-1—T SP-1—CS 4 E Buffalo AV 19.0' — 3.0' 1,2 2 15 30' - 15' 20OW - SV-2-TA SP-1-CS 6 S - - 19.0' 3.0 1 I- - _ - - _ - - z F i � 7 (175 LF) N �4 7 7 – – ♦ D Q 26-4-80 30' 40' 15' 20OW MAS SV-1—T SP-1—CS 6S 6th ��T 17.0' — 3.0' 1,2 ; //� 01 02 03 a 0' ® 15 30' — 15' 20OW — SV-2—TA SP-1—CS 8 W — — 17.0' 3.0' 1 // -� A 0 26-4-80 30' 45' 15' 20OW MAS SV-1—T SP-1—CS 8 W AV 10.0' — 3.0' 4 SV-1—T Buffalo s 1,2 c/ /�/ _ 0 / © 15 30' — 15, 20OW — SV-2—TA SP-1—CS 2 N — — 10.0' 3.0 1 Q7 26-4-80 30' 40' 15' 20OW MAS SV-1—T SP-1—CS 2 N 6th 115500 10.0' — 3.0' 1,2 ® 15 30' — 15' 20OW I — ISV-2—TAISP-1—CS[ 4 1 E — 9.0! 13.0'1 1 (100 LF) 7 / !TYPE IV (L) 7 \4 1. ALL EQUIPMENT NEW R/w ' .;` 2. INSTALL IISNS ON HORIZONTAL ARM PER DETAIL ON SHEET 1. '%' C _ ' — _ — — _ - - - -- W3-3 12 [7 (175 LF) 7 TYPE VI (R) 7 TYPE VI (R) /i,�,� 7 4o . Q / / / \�\ o l j �� �7 (225 LF) , �O P // ,6 5 4FO % 7 (100 LF) EXIST R26(S) / 7 / W2-1(SIGN ♦/ �i,>. / '� ' // 14 ONLY) \ O \\ C I I , 88 M7 TYPE VI (R) 36' ' 36' 10� STREET 14 I 2-N �4 ;' m ,// I I`-':.- -ETYPE IV (L) ♦ / / 7 \ \\\ NAME SIN CR=40 T III / \ \ \ \ F ,4I 1 II �/ CR=40 / � / - � \ \ \\ c SCE VAULT 7 \ \\ N ; III I INSTALL SIDEWALK (4'X25') / / � 17 9 10 I I 2 1 ( PER CITY STD PLAN 103 R/W � `, 1 JL"C, \ \ y \ \ \\ \\\ O // — +' O NSTALL (5'X22') PER 1-DLC / \�\ , i 19 3 14 R1-1 CITY STD PLAN 103 / ' / A, l/ I �3&S�8 �PV 6 ` —`` 06P �3 i 108' 1+ _ 6 6 I \ 1y2"C, 1-DLCJ / - - - ----- --- -- �\ loo, W3-3 15 \\ \ \ ,!._� -� G \ \ 10 g 1 05 / \ - _ TYp, III 5 G_ - E-�6 - / /// -- --- "'--------'" lo, / �,(� ,�, 6 I III 1 N 1k \ 'Qps Tp \ EXIS `� �ry s�q�� \\ nNc Rglsfp - - _ _ _ sa6 --� "t " -"-" �' ;E���' ' _ -' ''' ' / o, I \ Mf0/ _ R1 1 14 4 _ I 1 . \�\\� - _ _ - _ �5 3 III 5 \ N IEPS ,, /'�, EXIST W -r �5 >O 14 W2-1 -� III S - 5 III 10' 17 14 R1-1 1 "C 1-DLC a\ � � N - - - III �'"�' iv - _ III -�� MQUNT AT Cy 4 17 HEIGHT Ll 1 ;– – _ – ► 0 - ' III W N–SCpPE WC, 1–DLC ..SIDE _ _ _ WgIK_ – _– X01 W —1 W 2&�5 �_ 6';- – – _ sID F CAN lgNO _ �– 1 4 6 10 III – – _ EXIST W1-2, W13-1(40) SCAPE _''�' " \ \ 1 I I sb2 20 10 0 20 40 0 R/W t �2�'�\\ 04 5 o4 0 5 1 �7 02P ` / 6 ` F 1 F--- 0 R1-1 14 4 �-- E - s r— _ 17 R/W „ 8 ,� E IE /08 / 5 1"=20' GRAPHIC SCALE R26 S CA 12 O 04& 7 19' ,t;; SCE VAULT EXIST R26 S ( )( ) 6 I I 5 18 ( ) O 13 D3 / 6 R W O � I I -; 1l ► ' ,� ii 11T n i 8 CR=35 17 U I 1 II 14 R1-1 01 1 CR-35' i I 0 7 I Z 15 II I I 00 EXIST R26(S)(CA) 11 I iiS- 3 2 �� I L. .... 19 EXIST W1-2(R -L- _ 1 11 l \r �► I I 1 1 NO. DESCRIPTION OF REVISION DATE CITY 9 I APPROVED. 2"C, 4–#10 (SAFETY LIGHTING), 2–#12(IISNS) ' 18' 11' ► I 2"C, 3– 8 SERVICE CITY OF RANCHO CUCAMONGA 1 11 1 1 19 i f " # ( ) Jul 2 TRAFFIC SIGNAL PLAN 1 11 1 I I 1 1 3 t W 6TH STREET AND ' I BUFFALO AVENUE 11 7 (100 LF) 117 S ' I 1 1 GE Ess ti� APPROVED BY: DATE: �? / 3 100,/! I 1 / CITY ENGINEER 1� RCE: 2495S a / // V C9� tin DESIGN E>t_AN PREPARED 3Y: RECOMMENDED Kim Hom Underground Service Alert �% ' 36. / o seooiacee, Inc. - . /, R/W oc RCE 048252 � KD � �- 0A<5- Call: 7 '� Call: TOLL FREE " / / / / 14 1h"C, 1–DLC * Exp. 6/30/0 * DRAWN SHEET / / / / 1770 I WA A SUITE 200 O ` \� (951) 782- 41 6 >x 1-800 ATH UNrF » » `�" / l SI'f c l v l K D RIVERSIDE. CALIFORNIA 92507 © 2000 6 of 8 ,I� 227-2600 SJ��f�• ' T l , �E CHECKED R.C.E. NO—Q48� DRAWINt3 N0. OP INO DAYS BUORE YOU 010 30�- " TWO WORK NO . ' ._.. . DATE 03l19/Od FILE NO CONSTRUCTION NOTES MATCH SNF "o• _ ❑1 FURNISH AND INSTALL 8 PHASE NEMA CONTROLLER ASSEMBLY WITH moo, Eft 'go DETECTOR SENSORS, TELEPHONE MODEM AND AUXILIARY EQUIPMENT IN A TYPE R CABINET. EXACT LOCATION TO BE DETERMINED BY THE ENGINEER. SEE SHEET 1 FOR CABINET AND PAD DETAIL. ❑ FURNISH AND INSTALL MODIFIED TYPE III—BF SERVICE WITH ONE 5OA—IP CIRCUIT BREAKER FOR METERED SIGNALS, TWO 30A IP CIRCUIT BREAKERS FOR UNMETERED LIGHTING AND ONE 15A—IP CIRCUIT BREAKER FOR METERED I.I.S.N.S. PER STANDARD DRAWING NO. 407. / / 100';; I / ❑ 3 INSTALL 3" CONDUIT PER UTILITY COMPANY REQUIREMENTS. AT LEAST 48 HOURS ADVANCE NOTICE SHALL BE GIVEN TO SOUTHERN CALIFORNIA EDISON COMPANY BY CONTACTING ROB BOLTON AT (909) 930-8434. EXACT LOCATION OF CONDUIT SHALL BE DETERMINED BY SCE IN THE FIELD. / / 8 n y` ❑4 FURNISH AND INSTALL EVP DETECTOR ON MAST ARM PER DETAIL ON SHEET 1, WITH PHASES AS NOTED. ❑ REMOVE ALL CONFLICTING STRIPING, PAVEMENT LEGENDS, AND PAVEMENT 5 MARKINGS, BY WET SANDBLAST. /��/ '/ �/ 11•/ //// / \, ' g INSTALL 12" WHITE CROSSWALK WITH 10' BETWEEN PARALLEL LINES. 19, ❑ INSTALL PAVEMENT LEGENDS AND MARKINGS AS NOTED (PER CITY OF /i/ ;,%' co RANCHO CUCAMONGA STANDARD PLAN 133). ❑ 8 NOT USED. /��/ ;' Il. //C \� DCONSTRUCT CASE "C" WHEEL CHAIR RAMP PER CALTRANS STANDARD PLAN NSP A-88, DETAILS AS INDICATED. RECONSTRUCT AS NECESSARY FROM REMOVAL OF SUBSTANDARD WHEEL CHAIR RAMP. 10 INSTALL R3-4 SIGN ON MAST ARM. 11 RELOCATE TO OR INSTALL SIGN ON EXISTING POST AS NOTED. 12 RELOCATE TO OR INSTALL SIGN ON NEW POST AS NOTED. 13 REMOVE AND SALVAGE EXISTING SIGN AS NOTED. i v / 14 REMOVE AND SALVAGE EXISTING SIGN AND POST AS NOTED. 01 EXIST R26(S)(CA) 15 INSTALL SIGN ON STREET LIGHT POST AS NOTED. TRIM MEDIAN NOSE AS SHOWN. REMOVE AND REPLACE WITH FULL DEPTH AC / 1 1/2 "C, 16 �� / / / / 2—DLC 17 CONTRACTOR TO REQUEST AND COORDINATE THE REMOVAL AND SALVAGE OF EXISTING STREET LIGHTS WITH SOUTHERN CALIFORNIA EDISON. F118 INSTALL ±200' OF 2" CONDUIT WITH PULLROPE TO TELEPHONE SERVICE POINT 81 PER TELEPHONE COMPANY REQUIREMENTS. 7 19 FURNISH AND INSTALL SURFACE MOUNT WEATHERPROOF NEMA ENCLOSURE ON /�/ ; /�/ Az SIDE OF THE CONTROLLER CABINET FOR INTERCONNECT AND TELEPHONE ACCESS (PER CITY OF RANCHO CUCAMONGA STANDARD PLAN 408). 43 7 / 12 W3-3 7 JOIN EXIST STRIPING 20 10 0 20 40 CONDUCTOR SCHEDULE 01 CONDUIT RUNS 1"=20' GRAPHIC SCALE POLE AWG CIRCUIT 1 A2A& 5 9 DETECTOR SCHEDULE 1 �1,�6,�6P �4PP8 1 1 1 — — _ — 1 1 SENSOR DETECTOR CONTROLLER LOOPS PER 2 03,04,04P 06PP8 — — 1 1 1 1 _ — — — 1 1 NO. CHANNEL INPUT CHANNEL ' 3 03,08,08P 06PPB — _ — _ 1 — _ — _ 1 1 DETECTOR RACK #1 4 605,06906 08PPB — _ — _ — _ — _ — _ 1 1 1—S-03 3 1 5 02,05,02P 08PP6 — _ — _ — _ — _ — _ — _ 1 1 1 2 1—N-04 4 4 6 M J 07,08,08P 02PP6 — _ — _ — _ -- _ — _ — _ — _ 1 1 2 1 1—E-01 1 1 7 \ m 04,07,A4P 02PP6 — _ — _ — _ — _ — _ — _ 1 1 2 1—W-02 2 3 DETECTOR RACK 2 8 N v 01,02,02P 04PPB _ — _ — _ — — — — — 1 1 1 3 1 1—N—�7 7 1 1 1 UNUSED 19 — N0. DESCRIPTION OF REVISION DATE CITY TOTAL 1 4 1 2 1—S-08 8 2 2 UNUSED 20 — APPROVED. 10 SAFETY LIGHTING 2 2 2 2 2 2 1 2 4 — 1 1—W-05 5 1 1 UNUSED 17 — TYPE "C" 1 LOOP LEAD—IN — - — 2 2 — — 2 2 4 2 1—E-06 6 3 2 2 3-W-02 18 2 CITY OF RANCHO CUCAMONGA DLC 2 — — — — — 3 3 3 3 1 2—S-03 11 3 1 UNUSED 23 — 3 — — — — — — — 2 5 2 2—N-04 12 2 3 2 UNUSED 24 - TRAFFIC SIGNAL PLAN 4 — 2 2 2 2 — — 2 1 2—E-01 9 3 1 UNUSED 21 — 5 — — — — — 2 2 2 6 2 2—W—o2 10 4 4 2 3—E-06 22 2 Q 6 — — - 3 3 — — 3 3 1 2—N-07 15 3 1 UNUSED 27 - 6TH STREET AND a- 7 — 2 2 2 2 — — 2 2 7 2 2—S-08 16 4 5 2 UNUSED 28 — s — — — — — — — 2 2 8 1 2—W-05 13 3 6 1 UNUSED 25 - BUFFALO AV E N U E TOTAL — 4 4 9 9 5 5 17 18 2 2-E-06 14 4 2 UNUSED 26 — I.I.S.N.S. #12AWO 2 2 2 2 2 — 2 4 — 1 EVP 01&06 EVP 3 — 1 UNUSED 31 — EMERGENCY VEHICLE PRE—EMPTION 1 1 2 2 3 — 1 4 4 9* 2 EVP 02&05 EVP 4 — 7 2 UNUSED 32 — QR°FEs.S/ ` APPROVED BY: DATE: INTERCONNECT CABLE — — — — y — — — — 10* 1 EVP 03&08 EVP 5 — 8 1 UNUSED 29 — Cl` o4G� ..1 . CITY ENGINEER RCE: 2495 Underground Service Alert CONDUIT SIZE 2" 3" 3.5" 4" 4 2.5" 3" 2-4"2-4* * 2 EVP 04&07 EVP 6 — 2 UNUSED 30 — c�R DESIGN FLAN PRFPARED BY_ Ie Hom REO EN%p I %Eu F r ALL CONDUIT AND CONDUCTORS ARE NEW EVP DISCRIMINATOR CE 048252 KD C:- <,�, ►s� — Call: TOLL FREE * �P• 6/�/� * DRAWN ® and ssodatas• Inc. SHEET 1770 IOWA AVENUE, SUITE 200 1-800C s? C I V 1\, �P KD RIVERSIDE, CALIFORNIA 92507 © 2000 7 227-2600 �>g�, CA1.�F� (ast) -0941 R.C.E. NO 048252 __.�` _� TWO WONNO DAY3 BEFOK You Did DA Ob/19/Od FILE NO 94� . oO&_ CONSTRUCTION NOTES " 4 POLE SCHEDULE SEE NOTE 1 w3-3 s I 1 POLE DATA SIGNAL LUMINAIRE VEH SIG MTG PED SIG PPB I.I.S.N.S. LEGEND POLE LOC. Fil REMOVE AND SALVAGE EXISTING CSC-T1 CONTROLLER AND TYPE "P" CABINET. FURNISH I I 1� �; No. TYPE Ht. M.A. M.A. HIPS MAST MAST POLE MTG QUAD (SEE NOTE 2) E B C REMARKS AND INSTALL 8 PHASE NEMA CONTROLLER ASSEMBLY WITH DETECTOR SENSORS AND _ _ * _ , AUXILIARY EQUIPMENT IN A TYPE R CABINET ON EXISTING FOUNDATION. SEE SHEET 1 I I ', �; I I Q 1—A 10 — — — TV-1—UM SP-1—CS 8( ) W 1.5 — 5.8 CABINET AND PAD DETAIL. II 20 26-4-80 30' 40' 15' 20OW MAS-5A(N) MAS(N) — — — — AVE 18.1 — 18.7' a EXISTING TYPE "E" SERVICE WITH ONE 5OA-IP CIRCUIT BREAKER FOR METERED SIGNALS, Y , ~ ;� ;� I I Etiwanda (N) 8500 TWO 30A-IP CIRCUIT BREAKERS FOR UNMETERED LIGHTING AND ONE 15A-IP CIRCUIT a 1-A 10' - - - - - TV-1-T(N) SP-1-T 2 * N - ' BREAKER FOR METERED I.I.S.N.S. PER STANDARD DRAWING NO. 407 TO REMAIN. 3 I I �; ;; I I O ( ) ( ) - 1.4 2.8 , I 3 REPAINT ALL EXISTING CROSSWALKS NTH 12" WHITE PAINT. I I �� �; ;; j j ® 26-4-80(N) 30' 40'(N) 15'(N)20OW(N) MAS-5A(N MAS(N) SV-1—T(N) SP-1—T (N) N Arrow N 1281 2 3.2 — 3.6 ( ) 28� I �I INSTALL PAVEMENT LEGENDS AND MARKINGS AS NOTED (PER CITY OF RANCHO 1'�- Y< ;� 1 , ;� I 1 g 05 15(N) 30' — 15'(N)20OW(N) — — SV-1—TA(N) SP-1—CS(N 4(N) E — — o' 3.0' CUCAMONGA'S STANDARD PLAN 133). EXIST R26(CA) 1 1 '' �; 110 I I 12' I 1 j;� 48' ;� �; 36' 14' © 26-4-80 30' 40' 15' 20OW MAS-5A(N MAS(N) SV-1-T SP-1-CS 4(*) E AVE 8.0' - 3.0' a REPLACE EXISTING RAMPS WITH CURB, GUTTER, AND SIDEWALK. �, ,, Etiwanda (N) 8400 " I I 1-N-04s" i I 07 15 30' — 15' 20OW — — SV-2—TB SP-1—CS 6(*) S — — 7.9' 3.2' CONSTRUCT WHEEL CHAIR RAMP PER CITY OF RANCHO CUCAMONGA EXIST 1}2 C, 1-DLC I I � � 1 �' '' 112 STANDARD PLAN 102. 0 0 '-44{--------- ---- -} 'I I I ® 26-4-80 30' 45'(N 15' 20OW MAS-5A(N) MAS(N) SV-1—T SP-1—T 6(*) S Arrow (N) X2900 10.6' — 2.8' 7] INSTALL R3-4 SIGN ON MAST ARM. Red 12" Red 12" � 11; 1 11 �� I I 7 09 15(N) 30' — 15'(N)20OW(N) — — SV-2—TA(N SP-1—CS(N (N) W — — 8.2' r3 (Y F81 INSTALL R10-12 SIGN ON MAST ARM. Yellow0 0 12" Yellow 12" - , VAR4.- i I I F91 RELOCATE AND OR INSTALL SIGN ON NEW POST AS NOTED. I ; T —} T;� 1 ' �� 3 ' I 1 1. ALL EQUIPMENT EXISTING UNLESS NOTED OTHERWISE Green0 12" Green 12" 1 ; j ' I —Nl—�7�� I LJ 2. INSTALL IISNS ON HORIZONTAL ARM PER DETAIL ON SHEET 1. PROPOSED PHASE DIAGRAM 10 NOT USED. I I ; "; ;; I I A ADAPT MAST ARM TO POLE SIMPLEX IF NECESSARY GROUP GROUP 11 REMOVE AND SALVAGE EXISTING SIGN AND POST AS NOTED. Yellow 12" Yellow 12" 1 �' I I; r� -J j; I I I (N) NEW * Q Arrow Arrow I '; I I (*) REMOVE EXISTING PPB AND INSTALL ADA APPROVED PPB. SEE �, I 12 REMOVE ALL SIGNAL INDICATIONS WITH INCANDESCENT GREEN AND � I I, I , Z YELLOW LAMPS. INSTALL 12" LED INDICATIONS WHERE NEEDED. Green " I ; ► I; ; �; I I SPECIAL PROVISIONS. �----fl• I /2-_ 12 Green 12" ,,.� I I I; I ,; I I Q Arrow \� Arrow I I 4 13 REMOVE EXISTING PEDESTRIAN INDICATION MODULE. INSTALL LED I I; �; I I - COUNTDOWN TYPE MODULE. I I ; I I; ;� I I • \--R/W a - 0 14 INSTALL ±200' OF 2" CONDUIT WITH PULLROPE TO TELEPHONE R/W ; I ! ; I I / SERVICE POINT PER TELEPHONE COMPANY REQUIREMENTS. DETAIL A DETAIL B I I �* I ,. EXIST 1 C 1-DLC I I I I ' I ' r' (No Scale) (No Scale) I z l I I' l�- -J '' 11 2 V 15 FURNISH AND INSTALL SURFACE MOUNT WEATHERPROOF NEMA I I 1 ' ~ -� 1 ' - r` ENCLOSURE ON SIDE OF THE CONTROLLER CABINET FOR z I -N ' - �'' a '' I I INTERCONNECT AND TELEPHONE ACCESS (PER CITY OF RANCHO j j M ; ,I -''' 11' ZI ;i I I EXIST 2"C, 4#8 (SERVICE) * PROTECTED-PERMISSIVE LEFT TURN-HARDWIRE EXIST R3-7, R26(CA) I I ,--'�._ _-__ � rt�J I I ;; c� I! 4#10 (LT G.), 2 #12 (IISNS) CABINET FOR PERMANENT ANTI-BACKUP TO CUCAMONGA STANDARD PLAN 408). 04&05 OL) `�� �, ,� RL �1 2"C 4— 10 2—#12 PHASES 1 3 5 AND 7. SEE DETAIL 132 , _J I,, IY, J I, I I I BC Ar5ilr1olow ROUTE " ,2 13 I I I ,rr EXIST 2 C, 5-D C O7 / 11' ' ' ' ' I I;' \ -,> �; // 1 O8 EXIST 1 "C, 4-DLC STREET NAME SIGNS 11 I BC ,��� 1'�-`i;�, , I �;- 1 I lr I*�/ '>-Kg 13 6 1 EDISON VAULT R/W r%, L _J __J �__�i ------ EXIST ---- - ---- 15 14 EXIST R26(CA) O6 I L j ' �' O R W 14' 1 ' _ _ EXIST 1 C, 1-DLC � _ _ W3-3 9 5 " / EXIST 1"C, 1-DLC C3 06P 3&� - 8 - `t 1 13 RS 1 1 03 08 RS - s -_ F — — F G - - - - - - - - - - - - - - - • - - - - - - - - — - - n CB - ` 06 8 I I , R` � 6 �� — • • r -_J J 3- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - r - - �' I LSE DET IL "A" I I RL 12 I _ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - r_ - - - - - - - - - - - - - - - - - - - ,Y�� I I 3 y 12 1 1 SEE DETAIL "A" / RS , ; �\ 50' ._l 00 I I L� t ' 11 11 I 00 ; }-- �p I I ''i�• it ' EVP 06 ~ I 3 I , I i ; ' G G G G iG J�1— G - - - - - - - - - I� + 12 �- G ,�� I I w - - - - - - - - - - - - - - - - - - G G G G G - - - 1 i `�1 } '� TYPE IV(L) 4 �' / ,� -__�' f -- r--------------------------------------- I I C-4 11 -10 '- -�- �;� R 3-4 R ,� _ I N 4 TYPE IV(L) L--J ----------------------------- ------------------------------------------ - ------$ 8 - - - - - - - - - - - - - -- -- -- -- ---�_----__ -- -- -- -- -- -- --__ --�---- ----- ------------------------------------------ -�-- -+ - - - - - -w- - - - L ----- --------- ---------------�= CROSSWALK' -W-05 i I }S , 2-W-0� I r` i I' I 1'&06 I 8 I ------------' ------------------------------------------------------ --------------- -------------- -` ___= 4 4 C '' -'- S _ - -- -- - -- -- -- -- -- -- -- -- -- -------------- ---- - -- -- - - -- - -L L --------------- ------------- ------ i Il , r ---- RS AB 2 E �1� � 'L N a S— AB 2 LOOPS 2-W-02 I ' �� 1 I 05 , S -� r__� , 34 TO r r i F- I I , � � I N RL R3-4 � 1— Flc0sWALK -- T — T T �>r r ' L 1 ' 2 I I _ 10 E 02 T T > T � T T T T 3 -------- ----- ----------------------------------------- ---------- - 1 12 �► - - - - G- r G= - - - G—I - - - G GG n 1 c � � - - - - - - - 1 \\ -,-i G 3 17 11 G ' r r- , G r---1 3-W-02 \ r - r , I 2, /- , _ _ - - - � - - G G G G G � ` _ `\ _ � � I ' RS 1 X04& 7 .�+ZI� � -� - - - - - - �- I II �J L♦ \ I ♦ I I I " u AB "� " I 3- - - I- - - - - - - �— 50 L �; AB L 1 ► 1 , SEE DETAI A ISEDETAILDETAIL '' - $E DE IL "B'1 I RS �' r'` p I �~ 11 STREET NAME SIGNS - - - - - - - - - - - - - - - - � - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ��1& 6 II -= {} c �� OH r OH a, - a+- ON c� —�'r 1�- r �1 I -'''" � 4 S O W W°H W W W-a - - -�t-- _ _ 2"C, 1-DLC _ INTO EXIST 1INSTALL D'�C. I �� -~" �0 &07 I ' '' � ;; - 13 CB 6 � - 0 04 � ,n + O - - - - - - - - - - W3-3 9 50Q' TO EXIST M1-1(15), CB - - - - CC O RS I < �' ( ) 3 ''"�� _- g c� CROSSWALK Mg-1 10 BLUE)' INTOINSTll D'�C INSTALL 1-DISC R/W " RS �� �i , ,- ,► R/W " 1 �, M8--1(R)(BLUE), INTO EXIST 1 C. 1-C, 1-DLC B A 4P ; EXIST 1}� C, 1-DLC 2 MI EXIST R3-7, R26(CA) RC 1 11 �� RC Co .I J_ AB O LIJ ;1� x6 X ; FXIST R3-1, CONDUCTOR SCHEDULE * DETECTOR SCHEDULE �N TRUCKS", CONDUIT RUNS SENSOR DETECTOR CONTROLLER LOOPS PER RS °Df 'EV RL a/ �1 04 ; "TRAILERS" POLE AWG CIRCUIT N0. CHANNEL INPUT CHANNEL 3 1 2 3 4 5 Ae 1 02102P 08PP6 - _ - _ - _ DETECTOR RACK 1 20 10 0 20 40 � 2 02,�5,02P FLIT 08PP6 FLIT _ _ - _ - _ - _ 1 _ 1 1-S-03 3 1 T , , , , 1 R/yy 2 II 11 18 I _ _ I 3 V 04,07,08P 02PPB _ - - - - - 1 1 1 1 1-E-01 1 1 rJ II ) I 1 R/W „ 4 04,05,07,04P 02PPB 1 1 - _ - _ 1 2 , ;; I AB 1"=20' GRAPHIC SCALE _ _ _ 2 1-W-02 2 2 ,I N g v 01,02,06,02P 04PPB - 1 3 1 1-N-07 7 1 3 I �;a N ; I 6 M 01,06,06P,04PPB _ — _ — _ — _ — 2 1—S-08 8 1 — �.�L G� + _ _ j �_ DETECTOR RACK —2 05,08 04P,06PP6 _ _ _ _ I 1 UNUSED 7 N Q 03,04, 1 1-W-05 5 1 I II I r-- - 1 _ _ 8 .- v 03,08,08P 06PP6 - - - - - - - - - - 4 1 �� �� ' 2 3—N-04 20 2 9 02,05,06,06P 08PPB _ - _ - - - - - - - 1 1 2-E-03 106 61 3 0 6 L1 3 ;; , Q0 , L J� 2 1 UNUSED - - TOTAL 1 5 2 2-N-04 12 4 i I ;;1`___ �3 , ( 2 3-W-02 18 2 NO. DESCRIPTION OF REVISION DATE arY X10 SAFETY LIGHTING 2 2 2 2 2 - 1 2-E-01 9 3 3 1 UNUSED - - APPROVED. TYPE "C" 1 LOOP LEAD-IN - - - - - 2 6 2 2_W_02 10 2 2 UNUSED DLC 2 - 3 3 - - 3 1 2-N-07 15 3 I �� o a I % \\\` EXIST 4 1 UNUSED - - CITY O F RANCHO CUCAMONGA 3 - - - 2 2 2 �. 1Y2 C, 2 UNUSED 7 2 2-S-08 16 2 1 I 3 I - - = 4 - - 3 - - 3 1 2_W_o5 13 3 i �� - N I, 1-DLc 5 , UNUSED — — TRAFFIC SIGNAL MODIFICATION PLAN 5 - 2 2 - - 2 8 `�1 w ;+ `� 0 F -----� 2 UNUSED - - - - _ _ 2 2-E-06 14 4 I ,1 N -- I - 6 - 2 * 1 EVP 06 EVP 3 - I �� r -rr 6 1 UNUSED - - 7 - - 2 - - 2 9 2 EYP 02 EVP 4 2 UNUSED - - ETIWANDA AVENUE AND TOTAL - 5 10 3 4 2 10* 1 EVP 08 EVP 5 - I 111 1-S-0$t 1 1 o a 7 1 UNUSED 2 UNUSED - - ARROW ROUTE 2 EVP 04 EVP 6 - b j 0 I.I.S.N.S. 12AWG 2 2 2 2 2 - 1 UNUSED - - * EVP DISCRIMINATOR � 8 EMERGENCY VEHICLE PRE—EMPTION 1 1 2 — 1 4 1 2 UNUSED — — pROFESs/o INTE C NN CT CA LE — — — — — — I 4 ! F ��� APPROVED BY: DATE:- " " 1-2 1/2'(E) " ( yZ CITY ENGINEER RCE: 24953 CONDUIT SIZE 2 3 1-4" 3 3 1/2 2-3'(E) I 1 l 9 W3-3 I c� DESIGN F ^� � p�KCoY RECOMMENDED RCE 04825 A KIl Horn A in • ALL CONDUIT AND CONDUCTORS ARE NEW w i �� ,r � � 2 Jim ❑=® and Aasociotos, dna C� � � ' * P• 8/30% * DRAWN 1770 IOWA AANUF, SLIT[ 200 SHEET f' Q 2006 Civil,. Jim (9�iai c941 4+.I�oRr�� 92507 g _� = CA1.�F CHECKED DRAWING NO. I i i I R.C.E. NO 048252 DATE FILE NO 9443-NM '30OG—1