Loading...
HomeMy WebLinkAbout2037-DGENERAL NOTES CITY OF RANCHO CUCAMONGA UPPER CUCAMONGA STORM DRAIN AND 1 All work shall conform to the City of Rancho Cucamonga Standard Drawings and the Standard Specifications for Public Works Construction, (Green Book), 2003 Edition with supplements. 2. Public and private utilities and substructures shown hereon are from available records. The contractor shall be responsible for protecting all utilities and substructures as shown within the construction limits of this project and shall be responsible for any damage as a result of the construction operations. 3. a The contractor shall notify Underground Service Alert 1-800-422-4133 and the following utilities two working days prior to construction or regarding any problems. Southern California Edison Co. (909) 357-6585 Southern California Gas Co. (909) 335-7847 Verizon Communication (800) 469-6340 Cucamonga Valley Water District (909) 987-2591 Charter Communication (909) 343-5171 Metropolitan Water District (909) 217-6679 For inspection of this project, the Contractor shall Contact the Public Works Section at 477-2740 Ext. 4077 two working days prior to the required date. 5. A permit shall be obtained from the City of Rancho Cucamonga, prior to any construction or encroachment within any City of Rancho Cucamonga right-of-way. STREET WIDENING IMPROVEMENTS 6. The contractor shall notify the City of Rancho Cucamonga Police Department, The City of Rancho Cucamonga Fire Department and any affected school district, 72 hours prior to construction indicating any detour and/or road closures. 7. Contractor shall have a "Class A" Contractor Licence. EXISTING SURVEY MONUMENTATION All existing survey monuments that will be disturbed by this project shall be referenced and reset by the City Construction Surveyor in accordance with Section 8771 of the California Surveyors Act. Found monuments are shown on the plans and described as follows: (FOUND) STRIPING GENERAL NOTES 1. All details and dimensions for traffic striping and markings and the installation thereof shall conform to Caltrans, Standard Specifications, Traffic Manual, Maintenance Manual and Standard Plans and City Standard plan no. 133, unless otherwise approved or directed by the City Engineer. 2. Procedures for painting of striping and pavement markings and installation of pavements markers shall conform to the Standard Specifications for Public Works Construction and the following provisions. A. All pavement markings shall conform to the city maintenance stencils, (S.A.E) unless otherwise noted. B. All conflicting traffic striping and pavement markings shall be removed by WET SANDBLASTING. C. Sufficient control points and spotting removed during sandblasting shall be replaced prior to installation of striping and markings. D. All control points and spotting removed during sandblasting shall be replaced prior to installation of striping and markings. E. All control points and spotting shall be inspected and approved by the City Traffic Engineer prior to installation of new or replacement striping and markings. F. All striping and pavement markings installed on new road surfaces shall be approved low VOC type, 15 mil thick (wet). Installation shall be in two coats with the second a minimum of two weeks after the first, unless otherwise noted. g. All thermoplastic striping and pavement markings shall be installed in one coat and be 10 mil thick (dry), unless otherwise noted. H. Under no conditions shall a roadway be left over night, weekends or holidays without appropriate striping and markings to the satisfaction of the City Engineer. I. All traffic striping and pavement markings shall be installed with all appropriate permits and traffic control measures, in accordance with the city and state standards. J. Temporary or construction striping and markings shall be in accordance with the city and state standards and as directed by the City Engineer. STORM DRAIN GENERAL NOTES 1. All pipelines or substructures of any kind, telephone or power poles, water meters, waives, fire hydrants, etcetera, shown or not shown on these plans within the right-of-way limits or in adjacent areas where improvement work is to be done, shall be removed, relocated, or protected in place as required at no extra cost to the City of Rancho Cucamonga. 2. Any Contractor performing work on this project shall familiarize himself with the site and shall be solely responsible for any damage to existing facilities resulting directly or indirectly for his operations, whether or not such facilities are shown on these plans. 3. The Contractor shall reconstruct, replace or repair existing structures, pavement, curb and gutter , utility lines and other appurtenances affected by the installation of the storm drain system. PHASE 11 RANCHO HILLSI E CUCAMONGA SITE a_ w can BANY HIST 1 ¢ Q SUMMIT = a HIGH LAN VE 30 U' 19TH� 30 Z J a m J J a = � VICTORIA PARK L v QASEI LINE RD a VRO RH S DiNF THILL BLV C� 10500 C CCENTE LaiF>< oil ■ ARROW a m o a a BNSF RR Z w o > Q = 6TH ST w U (n 4TH ST _ VICINITY MNOT TO SC SHEET INDEX SECTION SHEET NO. DESCRIPTION I CHECKED BY CH 1 TITLE SHEET RECOMMENDED/APPROVED BY FLOOD CONTROL DEPARTMENT DATE STORM DRAIN IMPROVEMENTS PLAN 2 FROM STA. 01+00.00 TO STA. 12+00.00 z STORM DRAIN IMPROVEMENTS PLAN z a 3 FROM STA. 12+00.00 TO STA. 24+00.00 a o Z 4 STORM DRAIN IMPROVEMENTS PLAN FROM STA. 24+00.00 TO STA. 36+94.57 o DETAILS 5 TRAP CHANNEL TO R.C. BOX LATERALS 6 LATERALS "A-1" TO "B-4" cn z 7 HELLMAN AVENUE WIDENING w 01+00.00 TO 440' S. OF BASE LINE RD. �o in ir 8 SECTIONS DETAIL 4. Traffic control and safety shall be maintained by the Contractor in accordance with the standard of the State of California Business Transfortation and Housing Agency, Department of Transportation ( Caltrans "State of California Manual of Traffic Controls for Construction and "Maintenance Work Zone (S.A.F.T.) 1990 Editon, the special provision. Traffic control and safety devices shall be placed and maintained to the satisfaction of the Engineer. No such devices shall be removed or relocated without approval of the Engineer. 5. Contractor shall locate existing loop detectors and restore in place after installation of the proposed storm drain. 6. Prior to performing any excavation of the project the Contractor shall submit shoring drawings to the City Engineer for approval, if such shoring does not conform to the State of California Construction Safety Orders dealing with excavations and trenches as issued by the Division of Industrial safety then shoring calculations and drawings shall be prepared by a California Registered Civil Engineer. 7. Design of the R.C.P. shown on the contract drawings is based on the assumption the pipe will be installed in accordance with the pipe bedding detail as shown on City of Rancho Cucamonga Std. Dwg. No. 341. If the trench width exceeds the outside diameter of the conduit plus 20 inches the bedding shall be modified and/or pipe of additional strength shall be provided. The proposed modification shall be approved by the City Engineer. 8. Trench backfill shall conform to the City of Rancho Cucamonga Std. Dwg. No.120 and shall be verified by compaction tests to the satisfaction of the Engineer or his representative. 9. Compaction tests of embankment construction, trench backfill, compacting original ground and all sub -grades shall be performed by an independent testing firm and the City will bear the cost of said testing. The costs of all other tests, including the retesting of those that fail the first test, shall be borne by the contractor. A written report with these compaction tests will be submitted to the City Engineer. 10. Paving replacement along the trench shall be per City Standard plan no. 120. If aggregate base exist, the contractor shall replace aggregate base to match existing and all cost shall be included in the bid item per linear foot for reinforced concrete pipe. 11. Estimate of quantities is provided by the Engineer solely for the convenience of the Contractor. The Contractor shall make his own determination of construction quantities before submitting a bid. Any item of work required by these plans which is not specifically listed in the estimate of quantities shall be considered as included in the other items of work. 12. Locations of catch basins connection pipe junctions with catch basins shown on the drawings are schematic. It is intended that such junctions be located at the downstream end of the catch basin unless a detail of the connection is shown or a note specifically indicates otherwise, in all cases the exact locations will be determined in the fields by the Engineer to meet field conditions. 13. Sanitary sewers and house connections crossing over the storm drain trench shall be supported in accordance with the City of Rancho Cucamonga Std. Dwg. no.339 and encased per general note No.5 on said Std. Dwg. House connections shall be prepared per City of Rancho Cucamonga Standard Drawing No. 339, case 3. 14. When indicated on the drawings sanitary sewers and lateral connections shall be encased or blanketed in accordance with City of Rancho Cucamonga Standard Drawing No. 340. 15. Locations shown on the contract drawings for existing sanitary sewer house connections are approximate only. The Contractor shall field locate laterals. 16. City approval of these plans does not relieve the Contractor from responsibility for the correction of error and omission discovered during construction, upon request the required plan revisions shall be promptly submitted to the City Engineer for approval. 17. Work site and exterior streets shall be kept in a neat, clean, and hazard free, orderly state throughout construction site shall be cleaned upon request of the inspector. 18. The final surface layer of asphaltic concrete roadway pavement shall not be placed until all utilities and utility laterals within the roadway have been installed and all unacceptable parkway and roadway improvements are removed and replaced to the satisfaction of the City Engineer. Underground Service Alert Call: TOLL FREE 1-800 422-4133 TWO WORKING DAYS BEFORE YOU DIG STORM DRAIN CONSTRUCTION NOTES: 1a- CONSTRUCT P.C.C. TRAP. CHANNEL, b = 8', h = 8', z = 1, PER TYPICAL SECTION ON SHEET NO.6. 1A CONSTRUCT P.C.C. TRAP. CHANNEL, b = 10.6', h = 10, z = 0.671 PER TYPICAL SECTION ON SHEET NO.6. 2�- REMOVE EXISTING REINFORCED P.C.C. TRAP CHANNEL. - REMOVE EXISTING 24" CMP RISER WITH CONTROL PANEL INCLUDING CONC. PAD. �- SAWCUT AND REMOVE EXISTING A.C. SERVICE ROAD AND REPLACE WITH 3" A.C. OVER COMPACTED NATIVE. 5�- INSTALL 24" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 6a- CONSTRUCT P.C.C. COLLAR PER CITY OF RANCHO CUCAMONGA STD. DWG. NO. 329. �- INSTALL 36" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 8� CONSTRUCT CONCRETE PIPE CONNECTION PER SBCFCD STANDARD S.P. 200A. CONSTRUCT TRAP. CHANNEL TO RCB TRANSITION PER DETAIL ON SHEET NO.6. 10 PROTECT CHAINLINK FENCE IN PLACE. 11 CONSTRUCT 10' W X 10' H C -I -P R.C.B PER CALTRANS STANDARD PLAN D-80. 12 INSTALL 48" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 13 INSTALL 90" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 14 INSTALL 96" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 15 CONSTRUCT MANHOLE N0.3 PER CITY OF RANCHO CUCAMONGA STANDARD DRAWING N0. 320. (16 -CONSTRUCT TRANSITION STRUCTURE N0.1 PER CIN OF RANCHO CUCAMONGA STANDARD DRAWING N0. 334. 17 REMOVE EXISTING R.C.P. STORM DRAIN. 18 CONSTRUCT JUNCTION STRUCTURE N0.1 PER CITY OF RANCHO CUCAMONGA STANDARD DRAWING N0. 330. 19 CONST. SUPPORT FOR CONDUITS ACROSS TRENCHES PER CITY OF RANCHO CUCAMONGA STANDARD DRAWING N0. 339. Q- CONST. JUNCTION N0.2 PER CIN OF RANCHO CUCAMONGA STANDARD DRAWING N0. 331. CONST. BLANKET PROTECTION PER CIN OF RANCHO CUCAMONGA STANDARD DRAWING N0. 340. �- REMOVE INTERFERING PORTIONS OF EXISTING STORM DRAIN, PIPES, STRUCTURES MANHOLES, CATCH BASINS ETC. RELOCATE EXISTING 30" WATER LINE AND 42" CASING BY OTHERS. INSTALL CHAIN LINK FENCE ON TOP OF TRAP. CHANNEL WALL PER S.B.C.F.C.D. SPEC. DRWG. II. �- INSTALL CHANNEL WALL STEPS PER S.B.C.F.C.D. S.P.-214A AND S.P.-147 FOR DETAIL, INCLUDING 4' WIDE CHAIN LINK WALK GATE. FESS/ ---04,E �O >p1A a '9l y C3 No. 24953 m � Exp. 12-31-07 �F..OF CA` - BENCH MARK N0. 10048 2" BRASS DISK IN TOP OF CURB BRIDGE WALL OVER CUCAMONGA CREEK FLOOD CONTROL CHANNEL STAMPED "CITY OF RANCHO CUCAMONGA BM 10048 1987" AT S.W. CORNER OF CARNELIAN STREET AND RED HILL COUNTRY CLUB ROAD, 75 FT. WEST OF CENTERLINE OF CARNELIAN STREET ELEV.=1302.317 COUNTY OF SAN BERNARDINO DEPARTMENT OE PUBLIC WORKS DESIGNED BY RD2 DRAWN BY RD2 I CHECKED BY CH APPROVED BY: ASST. DIRECTOR OF PUBLIC WORKS DATE DIRECTOR OF PUBLIC WORKS DATE SUBMITTED BY: C.D.E. RECOMMENDED/APPROVED BY FLOOD CONTROL DEPARTMENT DATE •SAS SUI LT PLAN 60" �P" S.P.R.R. R/W o�� m /V11 S.P.R.R. R/W � S.P R.R. R NOTE: THE ACCESS ROAD AND OTHER AFFECTED FACILITIES WITHIN DISTRICT TIOR! iVOTES• RIGHT-OF-WAY SHALL BE RESTORED TO THE PRE-EXISTING CONDITION. STORM DRAIN CONSTRUC (D— CONSTRUCT P.C.C. TRAP. CHANNEL, b = 8', h = 8, z = 1, PER TYPICAL INSTALL CHAIN LINK FENCE ON TOP OF TRAP. SECTION ON SHEET NO.6. CHANNEL WALL PER S.B.C.F.C.D. S.P. II. 1 A CONSTRUCT P.C.C. TRAP. CHANNEL, b = 10.6', h = 101, z = 0.67', PER C�'5 — INSTALL CHANNEL WALL STEPS PER S.B.C.F.C.D. TYPICAL SECTION ON SHEET N0.6. S.P.-214A. AND S.P.-147 FOR DETAIL. O2 -- REMOVE EXISTING REINFORCED P.C.C. TRAP CHANNEL. INCLUDING 4' WIDE CHAIN LINK WALK GATE. 3a— REMOVE EXISTING 24" CMP RISER WITH CONTROL PANEL INCLUDING CONC. PAD. �— SAWCUT AND REMOVE EXISTING A.C. SERVICE ROAD AND REPLACE WITH 3" A.C. OVER COMPACTED NATIVE. Q5 -- INSTALL 24" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 6a— CONSTRUCT P.C.C. COLLAR PER CITY OF RANCHO CUCAMONGA STD. DWG. NO. 329. d ®— CONSTRUCT CONCRETE PIPE CONNECTION PER SBCFCD STANDARD S.P. 200A. 10 (�{�Movr�� 2XIV-rI'`j Rieff-at-WArt u FS+�= F0�.: �c�I� P �t� ftwum rncusc—T � NOTES REGARDING STATIONING: ALL STA110NING SHOWN FOR CATCH BASIN LOCATIONS TIES ARE BASE ON ROAD CENTERLINE STATIONS. ALL STATIONING SHOWN FOR STORM DRAIN MAINLINES AND LATERALS IS ALONG THE CENTERLINE OF MAINLINE CONDUIT. NOTES REGARDING UTILITIES: 1) THE CIN OF RANCHO CUCAMONGA DOES NOT ASSUME RESPONSIBILITY FOR THE ACCURACY OF ALL UTILITY LOCATION, IT IS THE CONTRACTOR RESPONSIBILITY TO PROTECT ALL EXISTING UTILITIES. 2) AS THE FIRST ORDER OF WORK, THE CONTRACTOR SHALL POTHOLE AND LOCATE ALL EXISTING UTILITIES, PRIOR TO EXCAVATION. Underground Service Alert Call: TOLL FREE 1-800 4 22- 4133 0 R om >> ,�� M904T P U)^%( "Owe 1-0 �`; %w" ec TWO WORKING DAYS BEFORE YOU DIG NO. DESCRIPTION OF REVISION DATE CITY OF RANCHO CUCAMONGA PLAN AND PROFILE UPPER CUCAMONGA STORM DRAIN IMPROVEMENTS FROM STA. 1+00.00 TO STA. 12+00.00 APPROVED BY:E2'4953 �p/��/7����� yJ : CITY ENGINEER /1 X -e- �' }? L �� RCE DESIGN PLAN PREPARED BY: RECOMMENDED RD2 CITY OF RANCHO CUCAMONGA -� 10500 CIVIC CENTER DRIVE DRAWN RANCHO CUCAMONGA, CA 91730 SH ielflz RD2 CHECKED CIN CH APPROVED: M 2 of 8 R.C.E. NO 24953 DRAWING NO. FlLE NO 2037 RIGHT—OF—WAY SHALL BE RESTORED TO THE PRE—EXISTING CONDITION UPPER SoP.R.R. R/W I STORM DRAIN CONSTRUCTION NOTES: 1�— CONSTRUCT P.C.C. TRAP. CHANNEL, b = 8', h = 8', z = 1, PER TYPICAL 10 SECTION ON SHEET NO.6. 11 1 A CONSTRUCT P.C.C. TRAP. CHANNEL, b = 10.6 , h = 109, z = 0.67%, PER TYPICAL SECTION ON SHEET NO.6. (2)— REMOVE EXISTING REINFORCED P.C.C. TRAP CHANNEL_ �— SAWCUT AND REMOVE EXISTING A.C. SERVICE ROAD AND REPLACE WITH 3" A.C. OVER COMPACTED NATIVE. @_ 5� INSTALL 24" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 6� CONSTRUCT P.C.C. COLLAR PER CffY OF RANCHO CUCAMONGA STD. DWG. N0. 329. .rL 7� INSTALL 36" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. O8 — CONSTRUCT CONCRETE PIPE CONNECTION PER SBCFCD STANDARD S.P. 200A. �— CONSTRUCT TRAP. CHANNEL TO RCB TRANSITION PER DETAIL ON SHEEP N0.6. it anol1D �Ct�11 P►t�l�i- e� - IA11vi�� �'bR ' �'�: r1�tL� 'io 1p.�" . f'uTIaR la �l�o►! ems' . CONSTRUCT 10' W X 101- H C—I—P R.C.B PER CALTRANS STANDARD PLAN D-80. REMOVE INTERFERING PORTIONS OF EXISTING STORM DRAIN, PIPES, STRUCTURES, MANHOLES CATCH BASINS, ETC. RELOCATE EXISTING 30" WATER LINE AND 42" CASING BY OTHERS. INSTALL CHAIN LINK FENCE ON TOP OF TRAP. CHANNEL WALL PER S.B.C.F.C.D. S.P. II. Q5 — INSTALL CHANNEL WALL STEPS PER S.B.C.F.C.D. S.P.-214A. AND S.P.-147 FOR DETAIL. INCLUDING 4' WIDE CHAIN LINK WALK GATE. NOTES REGARDING UTILITIES: 1) THE CITY OF RANCHO CUCAMONGA DOES NOT ASSUME RESPONSIBILITY FOR THE ACCURACY OF ALL UTILITY LOCATION, IT IS THE CONTRACTOR RESPONSIBILITY TO PROTECT ALL EXISTING UTILITIES. 2) AS THE FIRST ORDER OF WORK, THE CONTRACTOR SHALL POTHOLE AND LOCATE ALL EXISTING UTILITIES, PRIOR TO EXCAVATION. IJ 5 Underground Service Alert Call: TOLL FREE 1,-.800 \�:� 422-4133 1 �L TWO WORKING DAYS BEFORE YOU DIG N0. I CENTERLINE RC BOX CURVE DATA: NO. RADIUS DELTA LENGTH TANGENT Q 135.00' 38' 11' 50" 90.00' 46.74' I it anol1D �Ct�11 P►t�l�i- e� - IA11vi�� �'bR ' �'�: r1�tL� 'io 1p.�" . f'uTIaR la �l�o►! ems' . CONSTRUCT 10' W X 101- H C—I—P R.C.B PER CALTRANS STANDARD PLAN D-80. REMOVE INTERFERING PORTIONS OF EXISTING STORM DRAIN, PIPES, STRUCTURES, MANHOLES CATCH BASINS, ETC. RELOCATE EXISTING 30" WATER LINE AND 42" CASING BY OTHERS. INSTALL CHAIN LINK FENCE ON TOP OF TRAP. CHANNEL WALL PER S.B.C.F.C.D. S.P. II. Q5 — INSTALL CHANNEL WALL STEPS PER S.B.C.F.C.D. S.P.-214A. AND S.P.-147 FOR DETAIL. INCLUDING 4' WIDE CHAIN LINK WALK GATE. NOTES REGARDING UTILITIES: 1) THE CITY OF RANCHO CUCAMONGA DOES NOT ASSUME RESPONSIBILITY FOR THE ACCURACY OF ALL UTILITY LOCATION, IT IS THE CONTRACTOR RESPONSIBILITY TO PROTECT ALL EXISTING UTILITIES. 2) AS THE FIRST ORDER OF WORK, THE CONTRACTOR SHALL POTHOLE AND LOCATE ALL EXISTING UTILITIES, PRIOR TO EXCAVATION. IJ 5 Underground Service Alert Call: TOLL FREE 1,-.800 \�:� 422-4133 1 �L TWO WORKING DAYS BEFORE YOU DIG N0. I CENTERLINE RC BOX CURVE DATA: NO. RADIUS DELTA LENGTH TANGENT Q 135.00' 38' 11' 50" 90.00' 46.74' DESCRIPTION OF REVISION DATE = LI U LLJ S.P.R.R. R/W I— Cn CITY OF RANCHO CUCAMONGA PLAN AND PROFILE UPPER CUCAMONGA STORM DRAIN IMPROVEMENTS FROM STA 12+00.00 TO STA. 24+00.00 APPROVED BY: DATES CITY ENGINEER � RCE: 24953 DESIGN PLAN PREPARED BY: RECOMMENDED RD2 CITY OF RANCHO CUCAMONGA 10500 CIVIC CENTER DRIVE DRAWN RANCHO CUCAMONGA, CA 91730 S Roe 3 OF 8 CHECKED R.C.E. NO 24953 DRAWING NO. CRY I APPROVED: CH DATE FILE NO 2037 co o a z I I WQ / !,���'� w + � J Z H� F- I I x / - j p O a=h� �°° azo 7cn CUT OR SHAVE EXISTING SLOPE TO 1.1.5 SLOPE, ui�lAX. x I I o = in 5 W O TO CONSTRUCT RCB STORM DRAIN. CxD Q w¢ • v�- 6 I I 3 11 17 72 RC _ v f' p o O ry " \ 12 t ,, EXIST. 63 RCP N O r I �--� O } texas r+_- C�I 11.0• Q- . . . `- -LATERAL E-RA--L "-1"17 84" RCP O - --- -- . . S B C F C D EASEMENT_ p- 7 22 28-$00 2 6 - _" FiRFR C}Pi1�C�1 f 6 2" FI R QP71C CABLE _ F18ER CPTiC CABLE / _"-= -- - - - - - - - - --- - - - --- - - -- -- - -- - -- - - -- -- - - --- w i � _.., // LATERAL "B-3" � � Ljj C� 2 �� n PROTECT IN PLACE 5 2 5 = 20 S.B.C.F.C.D. EASEMENT PROTECT IN PLACE PROTECT IN PLACE �` O PLUG EXISTING c-,// o l f it V) Z 40" CMP WITH } % o o in v = iI �� U 1 / / N O • N Z W MORTAR AND BRICK// + z �o o r ;° o M� M= z 0 - LINE B z MnFZ // �(A ++z l o � I c 1 t=om U S.P.R.R. RAN a � S.P.R.R. RAN ,.,� � + Q Z �UF� �o-�� •U, o�z ow�w W Q oma 5 / �— F- o aLjj w F a !n in U J (n U (n .J m J Z O STORM DRAIN CONSTRUCTION NOTES: DELTA LENGTH TANGENT 6� CONSTRUCT P.C.C. COLLAR PER CIN OF RANCHO CUCAMONGA STD. 18-57' 54" 29.79' DRAWING. N0. 329. �3 90.00' � 7 7� INSTALL 36" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. � $ 11 CONSTRUCT 10' W X 10' H C—I—P R.C.B PER CALTRANS STD. PLAN D-80. 12 INSTALL 48" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 19 13 INSTALL 90" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 14 INSTALL 96" DIA. R.C.P. STORM DRAIN, D LOAD PER PLAN. 15 CONSTRUCT MANHOLE N0.3 PER CITY OF DRAWING N0. 320. RANCHO CUCAMONGA STD. �- 16 CONSTRUCT TRANSITION STRUCTURE N0.1 PER CITY OF RANCHO CUCAMONGA STANDARD DRAWING N0. 334. s UPPER REMOVE EXISTING R.C.P. STORM DRAIN. CONSTRUCT JUNCTION STRUCTURE NO.1 PER CITY STANDARD DRAWING NO. 330. CONST. SUPPORT FOR CONDUITS ACROSS TRENCHES PER CITY OF RNCHO CUCAMONGA STANDARD DRAWING NO. 339. CONST. JUNCTION NO.2 PER CITY OF RANCHO CUCAMONGA STANDARD DRAWING NO. 331. REMOVE INTERFERING PORTIONS OF EXISTING STORM DRAIN PIPES, STRUCTURES, MANHOLES, CATCH BASINS ETC. I � CUCAMONGA NOTES REGARDING STATIONING: ALL STATIONING SHOWN FOR CATCH BASIN LOCATIONS TIES ARE BASE ON ROAD CENTERLINE STATIONS. ALL STATIONING SHOWN FOR STORM DRAIN MAINUNES AND LATERALS IS ALONG THE CENTERLINE OF MAINLINE CONDUIT. NOTES REGARDING UTILITIES: 1) THE CITY OF RANCHO CUCAMONGA DOES NOT ASSUME RESPONSIBILITY FOR THE ACCURACY OF ALL U11UTY LOCATION, IT IS THE CONTRACTOR RESPONSIBIUTY TO PROTECT ALL EXISTING UTILITIES. 2) AS THE FIRST ORDER OF WORK, THE CONTRACTOR SHALL POTHOLE AND LOCATE ALL EXISTING UTILITIES, PRIOR TO EXCAVATION. DRAI N Underground Service Alert Call: TOLL FREE 1-& 800 HELLMAN AV. CENTERLINE RC BOX CURVE DATA: NO. RADIUS DELTA LENGTH TANGENT O 90.00' 18-57' 54" 29.79' 15.03' �3 90.00' 18' 48' 44" 29.55' 14.91' ® 90.00' 41' 39' 37 65.44' 34.24' 0 90.00' 22' 57' 46" 36.07' 18.28' 422-4133 I Q TWO WORKING DAYS BEFORE YOU DIG 1 NO. DESCRIPTION OF REVISION DATE Cny APPROVED: CITY OF RANCHO CUCAMONGA PLAN AND PROFILE UPPER CUCAMONGA STORM DRAIN IMPROVEMENTS FROM SQA. 24+00.00 TO STA 35+00.00 APPROVED BY: CITY ENGINEER -- ���G'C%� ��-� RCE: DATE: 249 3�� r= DESIGN PLAN PREPARED BY: RECOMMENDED RD2CITY OF RANCHO CUCAMONGAlku:) 10500 CIVIC CENTER DRIVE DRAWN S RANCHO CUCAMONGA, CA 91750 RD2 CHECKED CH 4 of 8 R.C.E. NO 24953 DRAWING NO. DATE FILE NO 2037 VVIVJ 11\VV 1 11\/'11 LLVIVnL VI 1/11rItlLL A 1 18" i VARIES (6.r TO 81 a N r 6—#5 Continuous 0 (TYP.) 2' Clear (Typ') W 2' Clear (Typ.) 'b TRANSITION PLAN SCALE: 1' = 8' VARIES (4' To 5.3' VARIES (4' To 5.31 #4 012' (Typ.) 15" Z 1 #4012 MAX. (Typ.) br 2' Sc bar 3'-9"\\— N �v 3'-6 2 a bar #5 @12- 4!' Clear #4 CONTINUOS (TYP.) VARIES (11' To 13.61 VARIES (6.r To 8) 18' N 2" Clear (Typ.) #4 a b bar Z 2' a bar 1 a bar -#6 @ 12 -/3'-6" Z=0.67 b bar - #6 @ 12 2 " C bar ��oj cbar -#6@12 #4 018 MAX. 4" DIA. WEEP HOLE 0 10' O.C., (TYP.) cc 012" (Typ.) 3" Clear TRANSITION TRAP. CHANNEL AND TRAP. CHANNEL, b=10.6', h=10' FROM. STA. 4+11.71 TO 6+47.14 FROM. STA. 6+47.14 TO 16+50 FROM. STA. 16+50 TO 18+52.55 18' 8' 4' LU 15" z #4 012" (Typ.) 2" Clear z (Typ.) w v 6—#5 lb Continuous (TYP.) 2" Clear 00 (Typ.) 1 1 4' DIA. WEEP HOLE 0 10' O.C., (TYP.) N }84 Continuous DESIGN DATA "�'' LOADS: EXTERNAL: 62.5 p.s.f. E.F.P. INTERNAL: 40.0 p.s.f. fc = 1,500 p.s.i. fs = 24,000 p.s.i. n = 8 #4 012' - 4" Clear #4 018- 4' i 8' , _ 18" #4 018" MAX. 3" Clear 11' SECTION 'A -A' TRAP. CHANNEL, b=8', h=8' FROM STA. 1+00 TO 4+11.71 AND FROM STA. 18+52.55 TO 20+20 TRAP. CHANNEL #4 012" MAX. (Typ.) 2' Clear (Typ-) 8� #4 d 012" (Typ.) 1 1� #4 012" (Typ.) y #4 012' (TYP•) 2, 3� N r ONE CUBIC FOOT PEA GRAVEL 3—#4 BACKFILL MATERIAL IN A Continuous BURLAP SACK, SECURELY TIED, (Typ.) AND INSTALL 6" SQUARE ALUMINUM OR GALVANIZED STEEL WIRE MESH HARDWARE CLOTH. (MIN. DIA. .03 ANCHOR FIRMLY TO BACKFACE TYPICAL. 2 # 4 CONT. EACH FACE )X y VARIES FROM 15' TO 18' ACCESS ROAD II -�--EXIST. CHAINLINK I FENCE �y i 2% TYP. I 3" A.C. PAVEMENT 3 #4 CONT. #4<% @ 12'� N w /�� •• #4 � 0 12" LL 11" 10'_0, 11 N SECTION 'B - B' SCALE: 1" = 2' 60' S.B.C.F.C.D. R/W 24' TRAPEZOIDAL CHANNEL INSTALL CHAINLINK PER S.B.C.F.C.D. SPEC. DRWG. II. WALL STEPS PER PER S.B.C.F.C.D. S.P.-214A -� z�.sr To �' � O w 1. ro �o 00 Q > TYPICAL SECTION TRAP.CHANNEL AND ACCESS ROAD 0 r w 0 0 ft0 0 r VARIES FROM 15' TO 18' ACCESS ROAD EXIST. CHAINLINK � FENCE i I 2% TYP. I li h 3" A.C. PAVEMENT PROPOSED TRAP. CHANNEL SEE BELOW FOR DETAIL 12" 1" CHAMPER w 00 2" CLR. #4 �C� 12" #4 CONT., TYP. EXTEND INV. LONG. bars 24" INTO CHANNEL FLOOR BEND TOP DECK LONG. barS INTO HEADWALL w 0 I 0 10" ' 5q�\ 4 � @ 12" k��4 #4 CONT. 24" � 24" SECTION 'C - C' SCALE: 1" = 2'