Loading...
HomeMy WebLinkAbout2288-D CITY 0 -F _RANC_1 _[0 CLfCAMONGA STORM DRAIN LIFT STATION MAINTENANCE AT A RCHIBALD AVE. SOUTH OF DEVON ST. AND ETIWANDA AVE. SOUTH OF ARROW RTE. GENERAL NOTES: ��, co 1. All work shall conform to the City of Rancho Cucamonga Standard Drawings and the Standard �� �_,� r Specifications for Public Works Construction, (Green Book). 2009 Edition and including the 2010 = .�j,o supplement. n. c s�"X E `��` �- �_ 1 -n -� 2. Public and Private utilities and substructures shown hereon are from available records. The (q to „ _ I= > 3 Contractor shall be responsible for protecting all utilities and substructures as shown within the , ,r� Po P 9 Almond Rd + f > construction limits of this project and shall be responsible for any damage as a result of the - L construction operations. I - Hillside Rd �' `a' 1L — �- t �f [ W1Is6n-A r w r, w I -Wilsan A1r 3. The Contractor shall notify Underground Service Alert 1-800-422-4133 and the following utilities two - (+il _ -a- ` t _rt_ r, working days prior to construction or regarding any problems. Banyan St — I P1I T ,�ft,L �-� - CC Southern California Edison Co. — EMERGENCY ONLY (800) 611-1911 `' Route 30 trl/ ttLLL I I t L it + ll .��r, w'n I . (u der construction) Southern California Gas Co. — EMERGENCY ONLY (800) 427-2000 , ,. _ Hig land Av Verizon Co. 909 469-6340 19th-St— # f_� Charter Communications 951 343-5171 ' ` ' Cucamonga Valley Water District 909 987-2591 rteRdT Base Lir •. y , _ as Lind d 4• The contractor shall notify the City of Rancho Cucamonga Police Department, The City of Rancho I Cucamonga Fire Department and an affected school district, 72 hours nor to construction 9 P Y P � indicating any detour and/or road closures. _ Foothil,�- I Faothl�l 1--- 5. For inspection of this project, the Contractor shall contact the Public Works Section at (909) aTf 477-2740, Mond Thursday, g days prior : , ' } :, I l T <. I �� Monday — ay, and at least two workin d nor to the construction start date. ARa { =�1�- F "� Arrow Rt �ll ` � � — ulj'1 i�— � 1� 6. A permit shall be obtained from the City of Rancho Cucamonga prior to any construction or 8tJL- l' 1� T-i— =; ;- -------- 1- encroachment within any City of Rancho Cucamonga easement or rights—of—way. 10 Freeway + :, --� 06th Sti- Project traffic 7. During the construction operations at least one 12' lane in each direction shall be provided for each a �I J direction of travel on all streets at all times except where noted on the control details. The �R ;` FL�-i `� 4th St Site traffic lanes shall be maintained on pavement and shall remain unobstructed. L9 'tet? J li� + i r — _J > �> °- > � sr _r I=Z_ 0 Freeway 8. The Contractor shall familiarize himself with all underground utilities, pipes and structures, and shall W o c 0 take sole responsibility for the repair/replacement. at no cost to the City. for any damage to said E m E underground utilities, pipes and structures. r' W 9. Contractor shall verify all conditions and dimensions shown on the plans at the site prior to commencement of any work. All discrepancies shall be reported for direction immediately to the City. VICINITY Zh 10. On the date and at the time of the submittal of the Bidders Proposal the Prime Contractor shall NOT TO SCALE possess any and all contractor licenses, in form and class as required by any and all applicable laws with respect to any and all of the work to be performed under this contract; Including but not limited to a Class W License (General Engineering Contractor) or a Specialty Class "C" license (Specialty Contractor) sufficient to cover all the work to be performed by the Prime Contractor in accordance with the provisions of the Contractors License Law (California Business and Professions Code. Section 7000 et. seq.) and rules and regulations adopted pursuant thereto. EXISTING SURVEY MONUMENTATION All existing survey monuments that will be disturbed by this project shall be referenced and reset by the City's Construction Surveyor in accordance with Section 8771 of the California Surveyors Act. Monuments found by research of available City records and by field survey are shown on the plans and described as follows: (None Found) I I SHEET INDEX QC14 AN Gt.S TO SHEET 2� 3. I N STAG V STAINLESS STE6 L 3-8•I l ENGLo5uRE 1•VL* AND Z—Ys omouvrs 1. TITLE SHEET DESCRIPTION OF REVISION DATE CRY ROVE: 2. PLAN AND SECTIONS 3. DETAILS CITY OF RANCHO CUCAMONGA TITLE SHEET STORM DRAIN LIFT STATION MAINTENANCE ca Underground AT ARMIKD AVE SOUTH OF DEVON ST. AND ETIWANDA AVE. SOUTH OF ARROW RTE. pFESS/ Service Alert o Q� ��,� APPROVED BY: DATE: 1/11/I �� �� P• S�•FG �� CITY ENGINEER ✓ RCE. 53672 Call: TOLL FRESNO. 53672 D� PLAN PREPARED BY: Rgymamnown 1 -800-422-4133 W �+! PK Exp. OF RANCHO CUCAMONGA Exp. 06-30-11 p� TWO WORKING DAYS BEFORE YOU DIG ! DRAW ANC CIVIC CENTER DRIVE C,V`� ` RRANCHO CUCAMONGA, CA 91730 '+rF of c�a.�F ' PK 1 OF 3 CFS DRAwM No. CB 2288—D 2 FT. 5 x 2.0 FLU ,c:SCENT I ; - 40UNT r�'(} V 20 t_ GENERAL (VOTES INSIDE D01 c 2" C.O. TO 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS. S.C.E. PULLBOX C----- -}-may ( �• j t IF L I G r� f llf/I T CrT I^� eP','',�'tas.awnr.. a, fbFPEF?i99feN FOR bAtel. 9:FA Rf4NG AND FE&T NO FQ BE Ifi_r'yfit �---MYERS OR EQUAL � -�-- RE'GE'P?'. r� 1201240 V ' 3W '80 Im 0 CHARGE LINE M IOK DISAIC 3. ALL UNDERGROUND CONDUIT TO BE SCHEDVLE40-PVC. WIRE TO BE 35 AMP C r - CC's FLG. 90' ELL (TYP.) � i RHW OR THW COPPER CONDUCTORS. •. pypr A7�f �-1'i y� 4. ALL PRACTICES AND PROCEDURES, MATERIAL AND PLACEMENT OF V 17J\R. � LIGH'. C3 D i0' ELL f TYP.) 60 A li•+ COMB. METER 8 MATERIALS SHALL CONFORM IN EVERY RESPECT TO THE STANDARD ,-t�SET 2 P i MAIN BY ELECT. PLANS AND SPECIFICATIONS OF THE CITY OF RANCHO CUCAMONGA. STR. SlZEI FIER] ZEA PS. 0 ��—.-- -- - -- - -----� ,ETI l 5::] • � I 0 PHENOLIC NAMEPLATES MEPLATES :?. I 5. NOSE TO 8E CUT TO LENGTH AND INSTALLED TAUT. Ti LIGHT C°'I___3 1. PUMP txr � � 40A 20A f••�--- PUMP CONTROL 3. UNNING <' 2P Ip PANEL - NEMA 3R S. MOTORS WILL PULL EXCESSIVE CURRENT IF WIRED BACKWARD 4. 5 FAILURE �:" I N c 7 V11TH INNER FRONT V I E17 OF 5. CLAP TIME METER 7. ALL MATERIALS SPECIFIED BY BRAND NAME MAY BE SUBSTITUTED DOOR OPEN INNER DOOR 6. HIGH WAT LIGHT PUMP � /� �{p I 1 20A 1 WITH AN APPOVED EQUAL s.:s•r_rexzrxa:.^• r_�m M::-• i l—UIW�f• Y , r Ip I I L-w -. -- -. ^.._ __ J SINCE WIRE MESH CAN NOT FIT S"X 3•x Its'GALV. ESSCO PUMP CONTROL PANEL � � 2"C - _ v2"c - 2�r2, 1 #I2G T�ccweioaa+es m. 1 +rs INTO CATCH BASIN OR MANHOLE IN N.T.S. sf _ 309, ONE PANEL THEN THE WIRE MESH 4#12 3 NEEDS TO BE IN SEPARATE PIECES HIGHWATER LIGHT AND ASSEMBLE INSIDE PER a' 03 BAR$ s 4'O.C. FAILSAFE Y HV—V-100 i AIETER AND PULL SECTION 'a;: d• :;: •�. `: ;4:• ,; 21 A 12A fA APPROVAL BY CITY'S INSPECTOR TACK Neto 1NC/ANDESCENT RED LAMP � ( MYER$ 0R EQUAL 7 PUMP RECEPT PANEL LIGHT c 2 - 8'-3/4" DIA. s•X 3t4"��� SI EXISTING CATCH BASIN .r GROUND RODS IN aacrroR aocrs " •� GROUND WELLS a HUTS a 12" O.C. OR MANHOLE E FLOOR 6" SEPARATION • 2" PVC CONDUIT R�C"JSAL_t) P\ND P_7-Tjv./ANDA I.-OLATION PANEL TO FINISH GRADE 3" STANDING �OUNTED ON PL N � IEW 3 SINGLE LINE DIAGRAM CONCRETE PAI} V11TH N.T.s. 2� N.T.s. c i. 4 - 112 DOLTS TYP,AT ALL BOLTS. DRILL EPDXY SET STAINLESS STEEL BOLT �'' ° EYE BOLT SEE 22 ON SHE 3 _ 314" COPPER CLAD GR UND, 2 CA. fL00 INSTALL 2-1/2" PVC SCH 80 UBMERSIBLE CABLE CONDUIT, MIN. 18" DEPTH, FOR (THERMAL MAGNETIC TYPE FURNISHED WITH PUMP ETIWANDA LOCATION INSTALL WATER MOTOR LEADS WITH SEAL OFF 40 " _ _ -TIGHT CONNECTION 6300 # TENSILE STRENGTH, NYLON AND COIL 36" OF WATER TIGHT C91 A PI OLI 1 B C 2 S/0 SECTION �: C -'T"' 1rI CABLES TO PANEL COVERED STAINLESS STEEL LIFTING EXTRA WIRE. ENTER THROUGH i 3 H.P. ARCHIBALD LOCATION +z 2-1/2" STRAIGHT CABLE. LEAVE 55" SLACK. SIDE OF EXISTING CABINET. , 1P THR D ___0 I�z 21 F.L.A. 2" C-4-S/0 CABLES - z PUMP POWER CABLE —� N PUMP 01 TO PANEL m — SCREEN MESH. SEE —2-1/2"" UQUIDTIGHT FLEXIBLE FS4 PUMP OFF _ _ r^ - = w HI-WATER ALARM, Uhf P OFF / NOTE: FS3 AND FS4 m a SECTION C-C THIS • NONMETALLIC CONDUIT (LFNC) Q FLOAT SWITCH ARE SHEET FOR DETAILS. ONLY INSTALLED AT JFS,3 PUMP ON U PUMP 0 ' INSTALL ESSCO SUBMERSIBLE PUMP 240 V; �+ ARCHIBALD LOCATION a INCLUDING ACCESSORIES (SEE 1 0; 3 W; LI APPENDIX IN SPECIFICATIONS). SEE 60 HZ SHEET 2 FOR LOCATION OF PUMP. L2 L2 240 V 2* 12 70 MOISTURE PROBE FS2 PUMP ON HI H2 IN 1Y2" WATER TIGHT CONDUIT PUMP FUI 10 A I _ �}.� FS1 PUMP OFF N ARCHIBALD LOCATION I xr xa 2 1 FSI OFF ELEV. 1278. 120 V 2 -----1 I RES 3 - N _2 E C I3- AND SERVICE O E T� IL 4 Ml 3 PUMP int ON 3 �o-j FS2 ON ELEV. 1279.83 SEE APPENDIX IN 22 k,T.S. p A ___-J SPECIFICATIONS A DLI MP! 4 FOR FLOAT SWITCH GRADE 1 H ' ( 4 MI 5 1 FS3 N d i _- •"'�� �, Rl-I b 0 ELEV. 1287.95 E,a(STING CATCH BASIN g � ,¢ � MP 6 4" 90' BEND, FLG. X $• OR MANHOLE �� � � � �� !�L ;� � ' ;� : ':•a FLG. WITH 4" PVCs -- o-- OUTLET IN WALL. - I FS 1 OFF I q FS4 HI WATER ALARM 2 N.T,S, 1 p._ » 12 R1 2 7 e --- - AND PUMP OFF ELEV. 1288 RI-2 111- orl RI 4" SPOOL, FLG. X FLG.---- FS2 ON -- -- ? 3 - 0 - 4 14 --} SPARES 4" FLANGE WITH STEPS ——-- l THREADED NIPPLE NOTES: I REs IS rs R 1. CONTRACTOR TO SUBMIT SHOP DRAWINGS ON ALL EQUIPMENT, PIPING, AND MISCELLANEOUS MATERIALS PROPOSED TO BE UTILIZED ON THIS PROJECT FS-3 R3-1 NO WATER D INDICATES TERM. 8. A. CONNECTIONS INSTALL STAINLESS STEEL ENCLOSURE, 11—h- AND PRIOR TO ORDERING SAME. FS-4 RUMP LIGHT ALARM A-2-1/2- CONDUITS HI--WATER RESET R -I 4 a. 2. LOCATION OF ALL PIPING AND EQUIPMENT SHALL BE APPROVED BY THE 1 T o-�8 s -o� s R3 16 17 _ 2 DESCRIPTION OF REVISION DATE enY 4" SBR (APPROX. 12' LONG), ENGINEER PRIOR TO INSTALLATION. - b- IIPFIIa1lEfl° ATTACH TO THREAD NIPPLE CLOSES OPENS LIGHT WITH STAINLESS STEEL HOSE 1288.45 1287.95 ALARM I6 R3 2 CITY �� �� RANCHO CUCAMONGACLAMPS, BOTH ENDS •� REQUIRES a,. OFF V HYSTENrsrs r BEFORE OPENING ON R4 4" FLANGE WITH + DECLINING WATER LEVEL DETAILS INSTALL ESSCO SUBMERSIBLE PUMP KARL, FLYTE OR EQUAL R4-2 STORM DRAIN UFT STATION MAINTENANCE THREADED NIPPLE Is Ie INCLUDING ACCESSORIES (SEE CHECK VALVE, SEE APPENDIX APPENDIX IN SPECIFICATIONS). SEE IN SPECIFICATIONS SHEET 2 FOR LOCATION OF PUMP. 4" 90' BEND, FLG. X FLG. v • ; . 4 CONTROL DIAGRAM AT A%NM AVE. SOUTH OF MV0fJ Sr. AND ETIwMOA AVE. SOUTH OF ARRA R'tE. Q1toFEss1 APPROVED BY: DATE Mib/I I CIT S �� Y ENGINEER / RCE 53672 h�v �• . Za OESM PLAN PREPARED BY. SECTION A -- A No. W672 � z PK CITY OF RANCHO CUCAMONGA * *-v OIiAt�l RANCHO CIVIC CENTER DRIVE M.T.S, p� Exp. 06-30-11 RANCHO CUCAMONGA, CA 91730 �. 01V PK 3 of 3 CHEOW RAL No ON01-0 NM ce ME F„E NO 2288—D