HomeMy WebLinkAbout2339-SFIVE SECTION
SIGNAL HEAD
INSTALL BOLTED TYPE POLE
^' "T� - ATTACH TOP OF
-T TO POLE PLATE
THREE SECTION
SIGNAL HEAD
".,.,,NAL COMPARTMENT
FIVE SECTION SIGNAL _HEAD
MOUNTING DETAIL
NOTE:
ALL SECTIONS 12"
NOTE:
ALL SECTIONS 12"
MAS -5A
R,Y,G = 02, 04, 06 or 08
YA,GA = 01, 03, 05 or 07
DETAIL "A" DETAIL B
SIGNAL DISPLAYS
SINGLE INPUT
EMERGENCY VEHICLE
PREEMPTION DETECTOR
1 1/2" TO 3/4-
REDUCER
N
MAST ARM
PELCO AB- 0155 -L
OR AB- 0132 -L
MOUNTING CLAMP FOR
EVP OPTICAL DETECTOR
EXIST. C & G
EXIST. C & G
Z
0
"R" CAB. i- "R" 3 2
4„ CAB.
° PAD
. ° ° n .
VARIES <
0 0.
10" >'
PLAN N
TYPE "R CABINET FOUNDATION AND
PAD DETAIL
NOTE: SPECIAL PROVISIONS FOR THIS WORK
ARE ON FILE IN THE OFFICE OF THE
CITY ENGINEER AND MUST BE USED.
REMOVABLE
STEEL CAP
8' -0" �
ARM LENGTH
60" 24"
SEE 24" 12"
"SIGN TAB"
DETAIL
A2
r -1 2 "COUPLING AT
BOTTOM -FOR
SIGN WIRING
NIPPLE &
6' -0" ONNECTORS
OR 6" BY OTHERS)
81 -0"
NOTE: LB CONDULET, STO CABLE, HANGING
HARDWARE & SIGN BY OTHERS
ARM TUBE
SIZE
(909)
GENERAL NOTES
LENGTH
END O.D. x BASE O.D. x THK.
(800)
MATERIAL SPECIFI ATIONS
8' -0"
2 3/8" x 3
1/2" x11 GA.
SWIFT
-
Steel of 48,000 psi minimum yield after fabrication
(800)
227 -2600
WATER -
BASE PLATES
(909)
ASTM A -35 Steel ASTM A -36 Steel
SEWER -
CUCAMONGA COUNTY WATER DISTRICT
(909)
& FLANGES
CABLE T.V. -
COMCAST CABLEVISION
(909)
BACK CLAMP
PIPE
SERVICE ALERT
ASTM A- 36 - -53 Grade 7 Steel
227 -2600
W/4 BOLTS
- DATE: 6
MATERIAL SPECIFICATIONS
y�° e611
JAMES J. ANDERSON
A
NO. 22863
(ASTM A -307)
BUTT WELDS
DESIGN
J. A.
Ground flush with base metal
LONGITUDINAL
RECOMMENDED
�•'�, i
All welds shall conform to AWS 01.1 weld
SIGNAL POLE
WELDS
spec'dacation
-
DIAMETER Al
FIN ABOVE
� FINISHED GRADE
OF 2 SHEETS
FINISH COATING
STRUCTURE
DRAWING NO.
2339 -S
Hot di galvanized per ASTM A -123
P 9 P
HARDWARE
Hot dip galvanized per ASTM A -153
DESIGN CRITERIA
1"
4 R CLAMP
STRUCTURE &
HARDWARE
In accordance with the Specification for Structural
Supports of Highwayy Signs, Luminares and
Traffic Signals. NHTO 1994
WELDING
In accordance with the Specification for Structural
1 1/2- DIA.
DEBURRED
Supports of Highwayy Signs, Luminares and
Traffic Signals. AASHTO 1994
SIGNAL POLE
HOLE IN
CLAMP
3"
8
_ +
6 DIA. HOLE IN
CLAMP SUPPLIED
WITH A TYPE F"
3" -16UNC BLUNT
POINT TAPPING
SCREW (PILOT HOLE
TO BE FIELD
CE
AS
ARM - -
3"
RAD. (HOLD)
REQ'D.
DRILLED)
_
NOTCH OR DRILL 1 " DIA. HOLE
FOR DRAINAGE N /POLEMET
Ct (FIELD DRILLED)
CLAMP DETAIL
4" RAD. i ^ i • L
9"
16 DIA.
DRILL SIGN TAB DETAIL
Eel 201 N41,11 I Fill 11111111111: � l�,
16Y2"
TY
0
w
E.C.R ---
w
\O
G
' O I
r O
15.
POLE LOCATION CODE
(EXACT LOCATION BY ENGINEER IN THE FIELD)
I.I.S.N.S. LEGEND DETAIL
RAN HO
UCA ONG
7 TRAFFIC SIGNAL LO-C /
/ATION
�
LOCATION MA�P'����
3"
4"
GENERAL NOTES
1. Traffic signal and highway safety lighting systems per CALTRANS Standard Plans and
Standard Specifications dated 2010, as shown on the plans and in the Special
Provisions.
2. Traffic signs, stripes and legends per CALTRANS Traffic Sign Specifications, Traffic
Manual, Maintenance Manual, and Standard Specifications. Conform pavement legends
to city stencils. Reflectorize all signs, stripes and legends.
3. Pavement markers and painting procedures for striping per Standard Specifications for
Public Works Construction, latest edition.
4. Locate all substructures prior to construction. Hand dig foundations until clear of
obstructions. Coordinate pole installations with overhead utility or substructrure
owners. Phone Underground Service Alert and concerned utility companies 48 hours
prior to construction. Location of utilities and substructures have been shown from
a search of available records. The Contractor shall conduct his operation in such a
manner as to protect not only the utilities and substructures shown, but other utilities
or substructures that may not be shown on these plans.
5. Obtain approval for exact equipment, crosswalk and limit line locations prior to final
placement. Perform preliminary striping layout prior to loop detector layout.
6. Vehicle indications shall be 12 ", pullboxes No. 5 and conduit 2" rigid metal except as
shown.
7. Electrical services shall be 120volt /240volt. Provide circuit breakers for signals (one
50 amp metered), illuminated signs (one 15 amp metered, and safety lighting (one
30 amp per 1200 watts or portion thereof unmetered). oordinate service details and
scheduling well in advance of need.
8. The CONDUCTOR SCHEDULE is furnished as an installation guideline only. It shall be
the Contractor's responsibility to provide the correct conductors required for the
intended operation.
UTILITY COMPANY
TEL. NO.
ELECTRICITY -
SOUTHERN CALIFORNIA EDISON COMPANY
(909)
947 -8269
GAS -
SOUTHERN CALIFORNIA GAS COMPANY
(800)
227 -2600
PHONE -
VERIZON CORPORATION
(909)
608 -1230
-
PACIFIC TELEPHONE COMPANY
(800)
227 -2600
WATER -
CUCAMONGA COUNTY WATER DISTRICT
(909)
987 -2541
SEWER -
CUCAMONGA COUNTY WATER DISTRICT
(909)
987 -2541
CABLE T.V. -
COMCAST CABLEVISION
(909)
890 -0886
UNDERGROUND
SERVICE ALERT
(800)
227 -2600
INDEX OF SHEETS
1 OF 2 TRAFFIC SIGNAL ELECTRICAL DETAILS
2 OF 2 TRAFFIC SIGNAL PLAN
NO.
DESCRIPTION OF REVISION DATE
APPROV
CITY
OF RANCHO CUCAMONGA
YOF,
TRAFFIC SIGNAL
v
ELECTRICAL DETAILS
'DNO�
CHURCH STREET
MAYTEN AVENUE
QaoresSlcv�<
APPROVED BY:
- DATE: 6
//Xz
y�° e611
JAMES J. ANDERSON
A
NO. 22863
CITY ENGINEER
R.C.E. NO.5367C
DESIGN
J. A.
OLE & ASSOCIATES, INC.
CONSULTING CIVIL ENGINEERS
AND LAND PLANNERS
RECOMMENDED
�•'�, i
frfJJJSHEET1
If Exp.12 -31 -13 IF
g CIVIL �.<
elF OF aA`\faP
9302 PITTSBURGH 91 3o23O
C909) 481 -6322
a
E No 22863
ATE 6 %� FILE No
DRAWN
J.A.
OF 2 SHEETS
CHECKED
DRAWING NO.
2339 -S
POLE SCHEDULE
POLE DATA
SIGNAL
M. A.
HPSV LUMINAIRES
SIGNAL MOUNTING
PPB
POLE LOCATION
I.I.S.N.S.
See Detail on Sheet 1
N0.
TYPE
HEIGHT
M.A.
WATTS
VEH.
M.A.
PED.
PHASE
ARROW
"B"
"E"
"C"
1
19 -3 -100
30'
30'
15'*
200
SV -2 -TA
MAS
SP -2 -CS
8
MAYTEN AVE. AND FOOTHILL BLVD. APPROX. 1300'. USE PULL BOX NEXT TO CONTROLLER
-18.5'
-
3.5'
Church * ** 11sT
800
2
26 -4 -100
30'
40'
15'
200
SV -1 -T
MAS-54
SP -1 -CS
8
�—
-
15.5'
3.5'
* *Mayten —�► AVE
3
15TS
30'
-
15'
200
SV -1 -T
-
SP -1 -CS
2
/06PPB
16.5'
-
3'
-
4
19 -3 -100
30'
25'
15
200
SV -1 -T
MAS
SP -1 -CS
2
�—
-
13.5'
5.5'
Church sr
iisoo
ENSURE ALL ADA AND MUTCD STANDARDS ARE STILL COMPLIANT.
15TS
30'
-
15'
200
SV -1 -T
-
SP -1 -CS
4
—►
13'
-
3'
-
2
4 -4 -100
30'
35'
12'
200
SV -1 -T
MMAS
SP -2 -CS
4
1
-
-3'
3'
4 Mayten ** t�
16
PPB POST
30"
-
-
-
-
-
-
6
—+
-
3'
3'
VIDEO DETECTION CABLE
8
PPB POST
30"
-
-
-
-
-
-
6
�—
3'
-
3'
4"
* INSTALL AT 90 DEGREES TO SIGNAL MAST ARM
ALL EQUIPMENT NEW
** I.I.S.N.S. ARROWS SHALL POINT SOUTHERLY
* ** I.I.S.N.S SHALL BE ONE SIDED FACING SOUTH
1❑
FURNISH AND INSTALL 8 PHASE NEMA TYPE 90 CONTROLLER ASSEMBLY WITH VANTAGE
g❑
INTERCEPT EXISTING 2" CONDUIT WITH SIC (12PR #19). REMOVE THE SIC
A
EDGE TYPE II VIDEO DETECTOR SYSTEM (OR APPROVED EQUAL) PER MANUFACTORS
�
FROM THE CONDUIT RUNNING EAST TO MALAGA AND REDIRECT IT TO THE
Q
STANDARDS AND AUXILIARY EQUIPMENT AS NECESSARY FOR OPERATION SHOWN
"R"
CONDUCTOR
CABLE
11-#14
1 - #12
CON UCTIOR
CABLE
3 - #14, PPB)
CONTROLLER SHOWN HEARON. INSTALL NEW SIC FROM THIS CONTROLLER TO
N INSTALL
02,05,08,06PO8P 0 PP
IN A TYPE CABINET. INSTALL A BATTERY BACK -UP SYSTEM IN A SEPARATE CABINET
-
THE CONTROLLER MALAGA DRIVE . 1100' CONNECT THE REDIRECTED
-
MOUNTED THE SIDE OF THE CONTROLLER CABINET. EXACT LOCATION TO BE DETERMINED
2/1
SIC (FROM MILLIKEN AVE.) AND THE NEW SIC (TO ALAGA) TO THE NEW CONTROLLER.
0205,02P /08PPB
GI
BY THE ENGINEER. SEE SPECIAL PROVISIONS.
-
-
�2
FURNISH AND INSTALL MODIFIED TYPE III -BF SERVICE ENCLOSURE
1/1
INSTALL 2 "C WITH SIC (12PR #19) TO CONTROLLER LOCATED ON THE NW CORNER OF
04,08P /02PPB
PER STD. DWG. No. 407 AND SPECIAL PROVISIONS.
INSTALL
MAYTEN AVE. AND FOOTHILL BLVD. APPROX. 1300'. USE PULL BOX NEXT TO CONTROLLER
PER CALTRANS STANDARD A24D
1 50A -SP CIRCUIT BREAKER METERED SIGNAL
a
FOR FINAL RUN TO CONTROLLER
04,04P /02PPB
1 30A -SP CIRCUIT BREAKER UNMETERED LIGHTING
�0
FURNISH AND INSTALL VANTAGE EDGE 2 RZ4AWDR CAMERA ON LUMINAIRE MAST ARM.
1 /1
1 15A -SP CIRCUIT BREAKER METERED I.I.S.N.S.
1 /1
5
3
❑
FURNISH AND INSTALL SINGLE INPUT /SINGLE OUTPUT EMERGENCY VEHICLE
11
FURNISH AND INSTALL VANTAGE EDGE VECTOR HYBIRD SYSTEM CAMERA ON LUMINAIRE MAST ARM.
1/1
PRE - EMPTION DETECTOR, WITH PHASES AS SHOWN.
1/1
s
01,06,08,04P,06P 771gR
3 -S -08
E2
NEW SERVICE CONDUIT TO BE INSTALLED PER LEWIS APARTMENT COMMUNITIES, HOMECOMING AT
E
INSTALL R73 -7 AT END OF MAST ARM PER ES -6T, DETAIL "U"
-
TERRA VISTA - PHASE 5 (CHURCH STREET AT MALAGA DRIVE) PLAN SHEET 2 OF THE ONSITE PLANS.
7
/06PPB
0/1
CONTRACTOR SHALL NOT INSTALL NEW SIGNAL SERVICE UNTIL ON -SITE CONTRACTOR INSTALLS THE
0/1
COORDINATE REMOVAL OF STREET LIGHT WITH SCE. INTERSECTION LIGHTING SHALL BE
-
NEW SERVICE CONDUIT. CONTRACTOR SHALL COORDINATE SIGNAL SERVICE WITH CONSTRUCTION OF
8
MAINTAINED AT ALL TIMES. COORDINATE W /SCE ON THE REMOVAL AND NEW SIGNAL LIGHTING
-
THIS SERVICE CONDUIT. CONTRACTOR SHALL PROVIDE NO MORE THAN 10' OF 3" CONDUIT TO JOIN.
-
INSTALLATION (TURN ON). FOR POLE 1 EITHER MOVE POLE NORTH TO AVOID CONFLICT WITH
0/1
0/1
1
THE EXISTING STREET LIGHT OR TEMPORARY RELOCATE THE EXISTING STREET LIGHTING.
2/2
3/3
4/4
ENSURE ALL ADA AND MUTCD STANDARDS ARE STILL COMPLIANT.
2/2
8/8
#12
INSTALL R3 -4 SIGN PER ES -6T, DETAIL "U"
2
2
2
PROVIDE TENON FOR FUTURE SIGNAL HEAD.
2
-
06 ;
• _
04P 08 3 0-2+ 08P �+ F n w
' 06 10 0
a 8 g 140 1 2 100' 285 WALK A
I -
_
Y'Y
1
R _ 5l 06 +01
- — - - 3
r in 06 +01 4 i /if 1
3 i , ✓' ° 2 -W -05 DETAIL B 02 +05
4 DETAIL B 2- 12PR #19 SIC
—400" TO X -WALK = 285' TO X -WALK T r
s vA iu 2 ! 7 DETAIL A 02 +05 3 '� 5 SEE NOTE 8 N
l; 1 125' 100' 3 ``l 311 2.5'C, 3- 12PR #19 SIB
04 , V 0 10 1 2
x 3 4 3 3 ~
r
06 +01 R
10 04 ,
_ I _
4P 04
4 6 E ° _
/Z-j I I " 2'C,2#6(SIGNAL)
2` /
CONDUCTOR SCHEDULE
AWG SIZE WIRE
OR CABLE TYPE
STD
PHASES
A
A
�
A
Q
1
CONDUCTOR
CABLE
11-#14
1 - #12
CON UCTIOR
CABLE
3 - #14, PPB)
1
02,05,08,06PO8P 0 PP
-
-
-
-
2/1
2/1
2
0205,02P /08PPB
-
-
-
-
-
1/1
3
04,08P /02PPB
O7
INSTALL
OD
OD
PER CALTRANS STANDARD A24D
,
a
(-4)
04,04P /02PPB
-
-
1 /1
1 /1
-
1 /1
5
01,06,02P /04PPB
-
1 /1
1/1
1/1
-
1/1
s
01,06,08,04P,06P 771gR
3 -S -08
2/1
2/1
2/1
2/1
-
2/1
7
/06PPB
0/1
0/1
0/1
0/1
-
0/1
8
/06PPB
-
-
-
-
0/1
0/1
1
TOTAL
2/2
3/3
4/4
5/5
2/2
8/8
#12
IISNS
2
2
2
2
2
-
#10
LUMINAIRES
2
2
2
2
2
-
#8
BONDING CABLE
1
1
1
1
1
1
EVP CABLE
EVP 6
-
-
1
1
1
4
12 PR #19
INTERCONNECT CABLE
-
-
-
-
-
-
VIDEO DETECTION CABLE
1
1
2
2
1
5
PERCENT FILL
11
14
21
25
11
20
CONDUIT SIZES
4"
4"
4"
4"
r
Underground
CALL
1-800
.11
• WORKING DAYS BEFORE YOU
O
N
_u
w
/)
SCALE IN FEET
0 20 40 60 :0
2 "C, 1 SIC
SEE NOTE 9
CONSTRUCTION NOTES FOR INSTALLATION WITH TRAFFIC SIGNAL
O1
yr, \T'
„y
, 3
O 6
CONTROLLE1
INPUT
5_ y
OINSTALL
1
Q
1
OINSTALL
3 gyp,
5
R Rl -1
'Z
REMOVE.
SANDBLAST PAINT TO BE REMOVED.
"C,
Uj
R
AND SALVAGE SIGN AS SHOWN
2 1 SIC
12
2 -S- 08
.'
SEE NOTE 9
2 "C, 1 SIC
SEE NOTE 9
CONSTRUCTION NOTES FOR INSTALLATION WITH TRAFFIC SIGNAL
O1
INSTALL
8" WHITE CHANNELIZING LINE (USING RAISED
PAVEMENT MARKERS)
CONTROLLE1
INPUT
PER RANCHO CUCAMONGA STD. 133. (CALTRANS STD. DETAIL 38C)
OINSTALL
1
Q
1
OINSTALL
3
5
PER CALTRANS STD. A24E.
Zr
REMOVE.
SANDBLAST PAINT TO BE REMOVED.
4
O5
REMOVE
AND SALVAGE SIGN AS SHOWN
1 -E -01
12
1
W3 -3 SIGN PER RANCHO CUCAMONGA STD.
26' 12'
12'
14,
2
O7
INSTALL
OD
OD
PER CALTRANS STANDARD A24D
,
a
WET SANDBLAST PAVEMENT MARKINGS TO BE
REMOVED.
STRIPING
GENERAL NOTES
4
v
1
1 -W -05
5
1
4
1
2
1 -E -06
6
2
2
1
3 -S -08
11
'
5
2
SPARE
12
-
2
1
2 -E -01
3
1
6
2
2 -W -02
X
2
7
1
SPARE
0
1
1
2
2 -S -08
16
'..
2
1
o
p}
13
1
8
2
N
14
2
1
EVP 01 &06
EVP 3
9*
2
EVP 02 &05
EVP 4
1
EVP 08
EVP 5
10*
2
EVP 04
EVP 6
h�
R
,
W3 -1
I6
' R
7
I
2 "C, 1 SIC
SEE NOTE 9
CONSTRUCTION NOTES FOR INSTALLATION WITH TRAFFIC SIGNAL
O1
INSTALL
8" WHITE CHANNELIZING LINE (USING RAISED
PAVEMENT MARKERS)
CONTROLLE1
INPUT
PER RANCHO CUCAMONGA STD. 133. (CALTRANS STD. DETAIL 38C)
OINSTALL
1
4" SOLID WHITE LANE LINE.
1
OINSTALL
3
THERMOPLASTIC 12" SOLID WHITE CROSSWALK
PER CALTRANS STD. A24E.
O4
REMOVE.
SANDBLAST PAINT TO BE REMOVED.
4
O5
REMOVE
AND SALVAGE SIGN AS SHOWN
1 -E -01
OINSTALL
1
W3 -3 SIGN PER RANCHO CUCAMONGA STD.
2
1 -W -02
PLAN 401B.
2
O7
INSTALL
THERMOPLASTIC PAVEMENT LEGEND AS SHOWN
PER CALTRANS STANDARD A24D
OR
REMOVE.
WET SANDBLAST PAVEMENT MARKINGS TO BE
REMOVED.
STRIPING
GENERAL NOTES
4
E
1
1. ALL STRIPING AND R.P.M.'S TO BE DONE PER THE CITY OF
RANCHO CUCAMONGA STD. PLAN 133.
2. ALL CONFLICTING SIGNING, STRIPING AND PAVEMENT MARKINGS SHALL
BE REMOVED AS DIRECTED BY THE ENGINEER. STRIPING SHALL BE
REMOVED BY WET SANDBLASTING.
3. ALL TRAFFIC LANE STRIPING SHALL INCLUDE RAISED
REFLECTIVE PAVEMENT MARKERS.
jPpOfESSIO��
W JAMES J. ANDERSON z
No. 22863
-V E,p12 -31 -13 1►
rl�rP CIVIL \FO���p
OF CP,
PHASE DIAGRAM
01 02 03
T
I
lI
04
*= PERMISSIVE LEFT TURN MOVEMENT. INSTALL JUMPERS IN
CONTROLLER ASSEMBLY FOR ASSURED ANTI- BACKUP TO PHASE 1 & 5.
DETECTOR SCHEDULE
SENSOR
CHANNEL
DETECTOR
CONTROLLE1
INPUT
ZONES PER
CHANNEL
DETECTOR RACK #1
1
1
SPARE
3
-
1
1
2
1 -N -04
4
2
2
1
1 -E -01
1
1
2
2
1 -W -02
2
2
2
1
SPARE
7
-
3
2
1 -S -08
8
2
4
1
1 -W -05
5
1
4
1
2
1 -E -06
6
2
2
1
SPARE
11
-
5
2
SPARE
12
-
2
1
2 -E -01
9
1
6
2
2 -W -02
10
2
7
1
SPARE
15
1
1
2
2 -S -08
16
2
2
1
2 -W -05
13
1
8
2
2 -E -06
14
2
1
EVP 01 &06
EVP 3
9*
2
EVP 02 &05
EVP 4
1
EVP 08
EVP 5
10*
2
EVP 04
EVP 6
* EVP DISCRIMINATOR
DETECTOR RACK #2
TRACT 18856
1
SPARE
19
1
1
2
SPARE
20
-
MADOLE 8c ASSOCIATES, INC.
1
SPARE
17
-
2
2
SPARE
18
-
1
SPARE
23
-
3
2
3 -S -08
24
1
12
SPARE
21
-
4
SPARE
22
-
1
SPARE
27
-
5
2
SPARE
28
-
1
SPARE
25
-
6
2
SPARE
26
-
7
1
SPARE
31
-
2
4 -S -08
32
1
1
SPARE
9
8
2
SPARE
30
=
DESCRIPTI ❑N of REVISI ❑NI DATE (APPROVED
CITY of RANCHO CUCAMONGA
TRACT 18856
TRAFFIC
SIGNAL INSTALLATION PLAN
CHURCH
STREET & MAYTEN AVENUE
APPROVED BY.
% DATE (o /7- s /
�
CITY ENGINEER : ii RCE: 53672
DESIGN
MADOLE 8c ASSOCIATES, INC.
RECOMMENDED
CONSULTING CIVIL ENGINEERS
AND LAND PLANNERS
...__ --
DRAWN
9302 PITTSBURGH AVENUE, SUITE 230
RANCHO CUCAMONGA, CA 91730
SHEET
(909) 481 -6322
2 DF 2
;PECIAL PROVISIONS FOR THIS WORK CHECKED RCE No 22863 DRAWING NO.
ARE ON FILE IN THE OFFICE OF THE
CITY ENGINEER AND MUST BE USED. DATE 9//-10//"? FILE No 2339 -S
PROJECT SHEET N0. 2--OF-2