Loading...
HomeMy WebLinkAbout01-14 - Resolutions RESOLUTION NO. 01-14 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING DEVELOPMENT REVIEW NO. 00-75, FOR THE DESIGN REVIEW OF DETAILED SITE PLAN AND ELEVATIONS FOR TRACT 14382, CONSISTING OF 38 SINGLE FAMILY LOTS IN THE LOW RESIDENTIAL DISTRICT (2-4 DWELLING UNITS PER ACRE) OF THE ETIWANDA NORTH SPECIFIC PLAN, LOCATED WEST OF ETIWANDA AVENUE AND NORTH OF WILSON AVENUE, AND MAKING FINDINGS IN SUPPORT THEREOF - APN: 225-071-70. A. Recitals. 1. Mastercraft Homes filed an application for the approval of Development Review No. 00-75, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Development Review request is referred to as "the application." 2. On the 14th day of February 2001, the Planning Commission of the City of Rancho Cucamonga conducted a meeting on the application and concluded said meeting on that date. 3. All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2. Based upon the substantial evidence presented to this Commission during the above- referenced meeting on February 14, 2001, including written and oral staff reports, this Commission hereby specifically finds as follows: a. The application applies to property located west of Del Norte Place, north of Altura Drive, and west of Cervantes Place (generally north of Wilson Avenue and west of Etiwanda Avenue); and b. The property to the north and east of the project site consists of existing single- family homes and the property to the west and south is designated for residential use and is currently vacant; and C. The project, with the recommended conditions of approval, complies with all development standards of the City of Rancho Cucamonga; and d. The development of 38 single family units on 11.88 acres of land is consistent with the Low Residential designation of the General Plan; and e. The application contemplates the development of 38 single-family residential lots within Tract 14382, originally subdivided under Tract 13527. PLANNING COMMISSION RESOLUTION NO. 01-14 DR 00-75 — MASTERCRAFT HOMES February 14, 2001 Page 2 3. Based upon the substantial evidence presented to this Commission during the above- referenced meeting on February 14, 2001, including written and oral staff reports, this Commission hereby specifically finds as follows: a. That the proposed project is consistent with the objectives of the General Plan; b. That the proposed design is in accord with the objectives of the Development Code, the Etiwanda North Specific Plan, and the purposes of the district in which the site is located; C. That the proposed design is in compliance with each of the applicable provisions of the Development Code and the Etiwanda North Specific Plan; and d. That the proposed design, together with the conditions applicable thereto, will not be detrimental to the public health, safety, or welfare or materially injurious to properties or improvements in the vicinity. 4. Based upon the findings and conclusions set forth in paragraphs 1, 2, and 3 above, this Commission hereby approves the application subject to each and every condition set forth below. Planning Division 1) All applicable conditions as contained in Planning Commission Resolutions 88-200, 88-200A, 90-119, and 90-120 shall apply. 2) Rear yard drainage swales shall not exceed a maximum slope of 6 percent. 3) Provide a minimum of 15 feet of flat, usable rear yard area adjacent to the rear of each structure. The usable rear yard area shall not exceed 5 percent slope. 4) Provide, where possible, a minimum 18-foot area in front of each garage that does not exceed 5 percent slope. Maximum driveway slope shall not exceed 15 percent. 5) Driveways for side-on garage units shall not exceed a width of 12 feet from the front property line to the turnaround area in front of the garage. 6) Driveway widths shall not exceed 16 feet at the curb. 7) Masonry return walls shall be provided between each unit. The walls shall be provided a decorative finish to match the building elevations. 8) Comer side yard walls shall be provided. The walls shall be provided a decorative finish to match the building elevations. The walls shall be set back a minimum of 5 feet behind the sidewalk. Landscaping shall be provided between the wall and the sidewalk and maintained by the homeowner. PLANNING COMMISSION RESOLUTION NO. 01-14 DR 00-75— MASTERCRAFT HOMES February 14, 2001 Page 3 Enciineering Division: 1) Install 12-inch pipe in each private cross lot drainage easement and a transition structure to each curbside drain outlet. 2) Individual rear yard drains can be less than 12-inch diameter, but still require a curbside drain outlet and appropriate transition structure. 3) Provide dissipation facilities where cross lot drains from Lots 2 through 7 and the temporary emergency access road discharge to a future development phase to the south (Tract 13527). 5. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 14TH DAY OF FEBRUARY 2001. PLANNING CO ISSION OF THE CITY OF RANCHO CUCAMONGA BY: Larry c iel, Chairman ATTEST Brad , SecreUFK I, Brad Buller, Secretary of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 14th day of February 2001, by the following vote-to-wit: AYES: COMMISSIONERS: MACIAS, MANNERINO, MCNIEL, STEWART, TOLSTOY NOES: COMMISSIONERS: NONE ABSENT: COMMISSIONERS: NONE