HomeMy WebLinkAbout03-110 - Resolutions RESOLUTION NO. 03-110
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
RANCHO CUCAMONGA, CALIFORNIA, APPROVING DEVELOPMENT
REVIEW DRC2003-00241,A DESIGN REVIEW OF BUILDING ELEVATIONS
AND DETAILED SITE PLAN FOR 42 SINGLE-FAMILY LOTS ON 6.59
ACRES OF LAND OF TRACT 16314 IN THE AMENDED TENTATIVE TRACT
MAP 15974 WITHIN THE VICTORIA ARBORS MASTER PLAN IN THE
VICTORIA COMMUNITY PLAN, EAST OF DAY CREEK BOULEVARD,
GENERALLY NORTH OF CHURCH STREET, AND MAKING FINDINGS IN
SUPPORT THEREOF- APN: 0227-161-41 thru 47.
A. Recitals.
1. Standard Pacific filed an application for the approval of Development Review
DRC2003-00241, as described in the title of this Resolution. Hereinafter in this Resolution, the
subject Development Review request is referred to as "the application."
2. On the 27th day of August 2003, the Planning Commission of the City of Rancho
Cucamonga conducted a meeting on the application and concluded said meeting on that date.
3. All legal prerequisites prior to the adoption of this Resolution have occurred.
B. Resolution.
NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission
of the City of Rancho Cucamonga as follows:
1. This Commission hereby specifically finds that all of the facts set forth in the Recitals,
Part A, of this Resolution are true and correct.
2. Based upon the substantial evidence presented to this Commission during the above-
referenced meeting on August 27, 2003, including written and oral staff reports, this Commission
hereby specifically finds as follows:
a. The property to the north and east of the project site are vacant and Joseph Filippi
Winery adjoins the project to the north. Church Street is generally to the south of the site, and
across Day Creek Boulevard to the west is vacant land and land under construction for a single-
family residential project; and
b. The proposed use, together with the conditions applicable thereto, will not be
detrimental to the public health, safety, or welfare or materially injurious to properties or
improvements in the vicinity; and
C. The project design is consistent with the Victoria Arbors Master Plan and the
following goals and policies:
i) The proposed residential uses are compatible to adjacent single-family uses
as opposed to more intense multi-family uses.
ii) The proposed infill project would create opportunities of a population that
reflect income, age, occupation, race, ethnic background lifestyle, values, interest, religion, and may
interact, exchange ideas, and realize common goals that are similar to the existing neighborhood to
the west.
PLANNING COMMISSION RESOLUTION NO. 03-110
DRC2003-00241 — STANDARD PACIFIC
August 27, 2003
Page 2
iii) The proposed use is in close proximity of a transportation network that is
consistent with community goals. The project would eventually be a part of infill single-family
residences within proximity to the 1-15 Freeway to the east via Base Line Road and Foothill
Boulevard, and the 210 Freeway to the north via Day Creek Boulevard.
3. Based upon the substantial evidence presented to this Commission during the above-
referenced meeting and upon the specific findings of facts set forth in paragraphs 1 and 2 above,this
Commission hereby finds and concludes as follows:
a. That the Development Review is consistent with the General Plan and the Victoria
Arbors Master Plan; and
b. The design or improvements of the tentative tract is consistent with the General
Plan and the Victoria Arbors Master Plan; and
C. The site is physically suitable for the type of development proposed; and
d. The design of the project is not likely to cause substantial environmental damage
and avoidable injury to humans and wildlife or their habitat; and
e. The project is not likely to cause serious public health problems; and
f. The design of the project will not conflict with any easement acquired by the public
at large, now of record, for access through or use of the property within the proposed subdivision.
4. An Environmental Impact Report (EIR)(State Clearinghouse No.8808291)was prepared
and certified by the City Council as a Master Environmental Impact Report for the Victoria Arbors
Master Plan. The California Environmental Quality Act (CEQA) provides that once a Master
Environmental Impact Report has been certified, no further Environmental Impact Report or Negative
Declaration is required for subsequent projects within the scope of the Master Environmental Impact
Report. On July 7, 1999,the City Council certified a supplement to the Environmental Impact Report
(State Clearinghouse No. 98041137). Based upon the facts and information contained in the
certified Environmental Impact Report, together with all written and oral reports, the Planning
Commission finds that there is no substantial evidence that the project will have a significant effect
upon the environment.
a. There have not been substantial changes in the project that require major revisions
to the previous Environmental Impact Report because of new significant environmental effects or
substantial increase in the severity of the previously identified significant effects.
b. There have not been substantial changes with respect to the circumstances under
which the project is undertaken, which will require major revisions to the previous Environmental
Impact Report because of the involvement of new significant environmental effects or a substantial
increase in the severity of previously identified significant effects.
C. There is no new information of substantial importance, which was not known and
could not have been known with the exercise of reasonable diligence at the time the Environmental
Impact Report was certified as complete, that shows any of the following: 1) the project will have
one or more significant effects not discussed in the previous Environmental Impact Report;
2) significant effects previously examined will be substantially more severe than shown in the
previous Environmental Impact Report; 3) mitigation measures or alternatives previously found not to
PLANNING COMMISSION RESOLUTION NO. 03-110
DRC2003-00241 — STANDARD PACIFIC
August 27, 2003
Page 3
be feasible would in fact be feasible, and would substantially reduce one or more significant effects
of the project but the project proponents decline to adopt the mitigation measure or alternative; or4)
mitigation measures or alternatives,which are considerably different from those analyzed in the Final
Environmental Impact Report, would substantially reduce one or more significant effects on the
environment, but the project proponents decline to adopt the mitigation measure or alternative.
5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above,
this Commission hereby approves the application subject to each and every condition set forth below
and in the Standard Conditions, attached hereto and incorporated herein by this reference.
Planning Division:
1) Construct blockwalls with caps between homes(i.e., along interiorside
and rear property lines) for permanence, durability, and design
consistency rather than wood fencing. Decorative block walls shall be
provided on all perimeter tract, street side yard, and front return walls.
2) Access gates to the rear yards shall be constructed from a material
more durable than wood gates. Acceptable materials include, but are
not limited to, wrought iron and plastic.
3) All pertinent Conditions of Approval contained in Development
Agreement 00-04 shall apply.
4) All Conditions of Approval per Planning Commission Resolution No. 01-
25 for Tentative Tract 15974 shall apply.
5) All, Conditions of Approval per Planning Commission Resolution
Nos. 01-23 and 03-54 for Development Review 01-04 shall apply.
6) The developer shall provide each prospective buyer written notice of
the winery. The written notice must disclose the uses and operation
within the winery and in a format as approved by the City Planner, prior
to issuance of building permits.
7) The developer shall provide each prospective buyer written notice of
the Victoria Gardens Regional Center, the neighborhood shopping
center located at the southeast comer of Base Line Road and Day
Creek Boulevard, and the Cultural Arts Center. The standard format for
the written notice shall be submitted for City Planner review and
approval prior to issuance of building permits.
8) Submit standard design of future trellis, patios, or covered patios that
may be added within the rear yard by the homeowners for City Planner
review. The standard design shall include notes stating that rolled roof,
metal, shingles, and asphalt shingles are not allowed. The standard
design shall be added to the Victoria Arbors Master Plan.
9) Landscape all front and side yards that are visible from the public
right-of-ways.
PLANNING COMMISSION RESOLUTION NO. 03-110
DRC2003-00241 — STANDARD PACIFIC
August 27, 2003
Page 4
10) Where rock cobble is used, it shall be real, native fieldstone. Other
forms of stone, such as stacked stone or ledgestone, may be
manufactured products.
11) Comer lots shall have parkway adjacent to the curb.
12) All walls visible from or facing a street shall be decorative masonry on
both sides.
13) Avoid identical or similar elevation schemes plotted on adjacent lots or
across the street from one another.
14) Provide conduit to connect to the street, pre-wire houses/buildings for
fiber-optic use (minimum Category 5 and RG-6), prior to release of
occupancy. Plans shall be submitted for City Planner review and
approval prior to issuance of building permits.
Engineering Division:
1) Provide a minimum of 3-inch conduit for future fiber-optic use on all
streets with connection through the parkway to each lot or parcel.
Submit the size, placement, location, and the provider of the conduit for
City Engineer review and approval, prior to issuance of grading permits
or final map approval, whichever occurs first.
2) The Traffic Impact Analysis fair share traffic mitigation for
improvements within the City shall be accomplished through the City's
established Transportation Fee Program. The Traffic Impact Analysis
fair share traffic mitigation for improvements outside the City limits shall
be proportionally paid prior to each final map recordation. Fair share
amount for DRC2003-00241 is $18,932.03, and DRC2003-00242
is $14,471.29.
3) School bus route study, including loading and unloading areas, shall be
determined and coordinated with the school district, and any
improvements recommended by the study shall be required and
completed to the satisfaction of the City Engineer.
4) All internal residential streets shall be developed in accordance with the
City's"Local Street"standard with typical mid-block section curb-to-curb
distance of 36 feet, (lane widths of 18 feet — 18 feet, except at
intersections).
5) Entry statements identified by the Victoria Community Plan and Day
Creek Boulevard Master Plan shall be accepted into the City's
Landscape Maintenance District. All others shall be maintained
through a Home Owners Association (HOA).
6) Street trees per City Standards shall be provided for all interior streets.
PLANNING COMMISSION RESOLUTION NO. 03-110
DRC2003-00241 —STANDARD PACIFIC
August 27, 2003
Page 5
7) No cross-lot drainage. Each unit shall drain to the street or a public
approved facility.
8) Landscape Maintenance District(LMD)areas shall have a maximum of
3:1 slopes with a maximum retaining wall of 30 feet, except the east
side of Day Creek Boulevard shall have a maximum slop of 4:1. Top of
slope and toe of slope shall have a minimum one-foot flat area to
pedestrian walkways(two-foot flat area at top of slope for larger slopes)
per City Standard.
9) Parkways shall be two percent from top of curb to back of walk.
Environmental Mitigation:
1) The applicant shall implement all pertinent mitigation measures
adopted in the Master Environmental Impact Report Victoria Arbors
Master Plan as covered by the Environmental Impact Report as
certified by the City Council of the City of Rancho Cucamonga. The
project shall comply with the Mitigation Monitoring Program contained in
the Final EIR entitled "Final Environmental Impact Report Victoria
Arbors Village SCH No. 98041137," except for Mitigation
Measures 4.7.3A, 4.7.38, and 4.7.3D.
6. The Secretary to this Commission shall certify to the adoption of this Resolution.
APPROVED AND ADOPTED THIS 27TH DAY OF AUGUST 2003.
PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA
BY:
Rich Macias, Chairman
ATTEST
Brad,puhk, S creta
I, Brad Buller, Secretary of the Planning Commission of the City of Rancho Cucamonga, do hereby
certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the
Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning
Commission held on the 27th day of August 2003, by the following vote-to-wit:
AYES: COMMISSIONERS: FLETCHER, MACIAS, McNIEL, McPHAIL
NOES: COMMISSIONERS: NONE
ABSENT: COMMISSIONERS: STEWART
COMMUNITY DEVELOPMENT
DEPARTMENT
STANDARD CONDITIONS
PROJECT#: DRC2003-00241
SUBJECT: DESIGN REVIEW
APPLICANT: STANDARD PACIFIC HOMES
LOCATION: EAST OF DAY CREEK BOULEVARD, NORTH OF CHURCH STREET
ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT.
APPLICANT SHALL CONTACT THE PLANNING DIVISION,(909)477-2750,FOR COMPLIANCE
WITH THE FOLLOWING CONDITIONS:
A. General Requirements Completion Date
1. The applicant shall agree to defend at his sole expense any action brought against the City, its _J—j—
agents,officers,or employees,because of the issuance of such approval,or in the alternative,to
relinquish such approval. The applicant shall reimburse the City, its agents, officers, or
employees, for any Court costs and attorneys fees which the City, its agents, officers, or
employees may be required by a court to pay as a result of such action. The City may,at its sole
discretion,participate at its own expense in the defense of any such action but such participation
shall not relieve applicant of his obligations under this condition.
2. Copies of the signed Planning Commission Resolution of Approval No. 03-110, Standard —j--j—
Conditions, and all environmental mitigations shall be included on the plans (full size). The
sheet(s) are for information only to all parties involved in the construction/grading activities and
are not required to be wet sealed/stamped by a licensed Engineer/Architect.
B. Time Limits
1. This tentative tract map or tentative parcel map shall expire, unless extended by the Planning
Commission, unless a complete final map is filed with the City Engineer within 3 years from the
date of the approval.
2. Conditional Use Permit, Variance, or Development/Design Review approval shall expire if
building permits are not issued or approved use has not commenced within 5 years from the date
of approval. No extensions are allowed.
C. Site Development
1. The site shall be developed and maintained in accordance with the approved plans which include
site plans,architectural elevations,exterior materials and colors,landscaping,sign program,and
grading on file in the Planning Division, the conditions contained herein, Development Code
regulations, and the Victoria Arbors Master Plan.
SC-07-03 1
Project No. DRC2003-00241
Completion Date
2. Prior to any use of the project site or business activity being commenced thereon,all Conditions
of Approval shall be completed to the satisfaction of the City Planner.
3. Occupancy of the facilities shall not commence until such time as all Uniform Building Code and
State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be
submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety Division
to show compliance. The buildings shall be inspected for compliance prior to occupancy.
4. Revised site plans and building elevations incorporating all Conditions of Approval shall be
submitted for City Planner review and approval prior to the issuance of building permits.
5. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for
consistency prior to issuance of any permits (such as grading, tree removal, encroachment,
building,etc.) or prior to final map approval in the case of a custom lot subdivision, or approved
use has commenced, whichever comes first.
6. Approval of this request shall not waive compliance with all sections of the Development Code,all
other applicable City Ordinances, and applicable Community or Specific Plans in effect at the
time of building permit issuance.
7. A detailed on-site lighting plan, including a photometric diagram,shall be reviewed and approved
by the City Planner and Police Department(477-2800) prior to the issuance of building permits.
Such plan shall indicate style, illumination, location,height,and method of shielding so as not to
adversely affect adjacent properties.
8. If no centralized trash receptacles are provided,all trash pick-up shall be for individual units with
all receptacles shielded from public view.
9. All ground-mounted utility appurtenances such as transformers, AC condensers, etc., shall be
located out of public view and adequately screened through the use of a combination of concrete
or masonry walls,berm ing,and/or landscaping to the satisfaction of the City Planner. For single-
family residential developments,transformers shall be placed in underground vaults.
10. Street names shall be submitted for City Planner review and approval in accordance with the
adopted Street Naming Policy prior to approval of the final map.
11. All building numbers and individual units shall be identified in a clear and concise manner,
including proper illumination.
12. The Covenants, Conditions, and Restrictions (CC&Rs) and Articles of Incorporation of the
Homeowners'Association are subject to the approval of the Planning and Engineering Divisions
and the City Attorney. They shall be recorded concurrently with the Final Map or prior to the
issuance of building permits, whichever occurs first. A recorded copy shall be provided to the
City Engineer. The Homeowners' Association shall submit to the Planning Division a list of the
name and address of their officers on or before January 1 of each and every year and whenever
said information changes.
13. All parkways, open areas, and landscaping shall be permanently maintained by the property
owner,homeowners'association,or other means acceptable to the City. Proof of this landscape
maintenance shall be submitted for City Planner and City Engineer review and approved prior to
the issuance of building permits.
14. The developer shall submit a construction access plan and schedule for the development of all
lots for City Planner and City Engineer approval; including, but not limited to, public notice
requirements,special street posting,phone listing for community concerns,hours of construction
activity, dust control measures, and security fencing.
15. Six-foot decorative block walls shall be constructed along the project perimeter. If a double wall
condition would result, the developer shall make a good faith effort to work with the adjoining
property owners to provide a single wall. Developer shall notify, by mail,all contiguous property
owner at least 30 days prior to the removal of any existing walls/ fences along the project's
perimeter.
SC-07-03 2
Project No. DRC2003-00241
Completion Date
16. Construct block walls between homes(i.e.,along interior side and rear property lines),rather than
wood fencing for permanence, durability, and design consistency.
17. Access gates to the rear yards shall be constructed from a material more durable than wood
gates. Acceptable materials include, but are not limited to, wrought iron and PVC.
18. For residential development, return walls and corner side walls shall be decorative masonry.
19. On corner side yards, provide minimum 5-foot setback between walls/fences and sidewalk.
20. Where rock cobble is used,it shall be real river rock. Other stone veneers may be manufactured
products.
D. Building Design
1. All dwellings shall have the front,side and rear elevations upgraded with architectural treatment,
detailing and increased delineation of surface treatment subject to City Planner review and
approval prior to issuance of building permits.
2. Standard patio cover plans for use by the Homeowner's Association shall be submitted for City __J-__J_
Planner and Building Official review and approval prior to issuance of building permits.
3. All roof appurtenances, including air conditioners and other roof mounted equipment and/or
projections, shall be shielded from view and the sound buffered from adjacent properties and
streets as required by the Planning Division. Such screening shall be architecturally integrated
with the building design and constructed to the satisfaction of the City Planner. Details shall be
included in building plans.
E. Parking and Vehicular Access (indicate details on building plans)
1. Multiple car garage driveways shall be tapered down to a standard two-car width at street.
2. On flag lots, use a 12-foot driveway within flag to maximize landscape area.
F. Trip Reduction
1. Category 5 telephone cable or fiber optic cable shall be provided for office buildings and single-
family developments of 500 or more units.
G. Landscaping
1. A detailed landscape and irrigation plan, including slope planting and model home landscaping in
the case of residential development, shall be prepared by a licensed landscape architect and
submitted for City Planner review and approval prior to the issuance of building permits or prior
final map approval in the case of a custom lot subdivision.
2. All private slopes of 5 feet or more in vertical height and of 5:1 or greater slope,but less than 2:1
slope, shall be,at minimum, irrigated and landscaped with appropriate ground cover for erosion
control. Slope planting required by this section shall include a permanent irrigation system to be
installed by the developer prior to occupancy.
3. All private slopes in excess of 5 feet, but less than 8 feet in vertical height and of 2:1 or greater.
slope shall be landscaped and irrigated for erosion control and to soften their appearance as
follows: one 15-gallon or larger size tree per each 150 sq.ft.of slope area, 1-gallon or larger size
shrub per each 100 sq.ft.of slope area, and appropriate ground cover. In addition,slope banks
in excess of 8 feet in vertical height and 2:1 or greater slope shall also include one 5-gallon or
larger size tree per each 250 sq. ft. of slope area. Trees and shrubs shall be planted in
staggered clusters to soften and vary slope plane. Slope planting required by this section shall
include a permanent irrigation system to be installed by the developer prior to occupancy.
SC-07-03 3
Project No. DRC2003-00241
Completion Date
4. For single-family residential development, all slope planting and irrigation shall be continuously
maintained in a healthy and thriving condition by the developer until each individual unit is sold
and occupied by the buyer. Prior to releasing occupancy for those units, an inspection shall be
conducted by the Planning Division to determine that they are in satisfactory condition.
5. Front yard and corner side yard landscaping and irrigation shall be required per the Development
Code and the Victoria Arbors Master Plan. This requirement shall be in addition to the required
street trees and slope planting.
6. The final design of the perimeter parkways,walls,landscaping,and sidewalks shall be included in
the required landscape plans and shall be subject to City Planner review and approval and
coordinated for consistency with any parkway landscaping plan which may be required by the
Engineering Division.
7. Special landscape features such as mounding, alluvial rock, specimen size trees, meandering
sidewalks (with horizontal change),and intensified landscaping, is required along Church Street
and Day Creek Boulevard.
8. Landscaping and irrigation systems required to be installed within the public right-of-way on the
perimeter of this project area shall be continuously maintained by the developer.
9. All walls shall be provided with decorative treatment. If located in public maintenance areas,the
design shall be coordinated with the Engineering Division.
H. Signs
1. The signs indicated on the submitted plans are conceptual only and not a part of this approval.
Any signs proposed for this development shall comply with the Sign Ordinance and shall require
separate application and approval by the Planning Division prior to installation of any signs.
I. Environmental
1. The developer shall provide each prospective buyer written notice of the 210 and 1-15 Freeways
in a standard format as determined by the City Planner,prior to accepting a cash deposit on any
property.
2. A final acoustical report shall be submitted for City Planner review and approval prior to the
issuance of building permits. The final report shall discuss the level of interior noise attenuation
to below 45 CNEL, the building materials and construction techniques provided, and if
appropriate,verify the adequacy of the mitigation measures. The building plans will be checked
for conformance with the mitigation measures contained in the final report.
3. The applicant shall submit certification from an acoustical engineer that all recommendations of
the acoustical report were implemented in construction, including measurements of interior and
exterior noise levels to document compliance with City standards. Certification shall be
submitted to the Building&Safety Division prior to final occupancy release of the affected homes.
4. Mitigation measures are required for the project. The applicant is responsible for the cost of
implementing said measures, including monitoring and reporting. Applicant shall be required to
post cash, letter of credit, or other forms of guarantee acceptable to the City Planner in the
amount of $719.00 prior to the issuance of building permits, guaranteeing satisfactory
performance and completion of all mitigation measures. These funds may be used by the City to
retain consultants and/or pay for City staff time to monitor and report on the mitigation measures.
Failure to complete all actions required by the approved environmental documents shall be
considered grounds for forfeit.
SC-07-03 4
Project No. DRC2003-00241
Completion Date
I Other Agencies
1. The applicant shall contact the U.S. Postal Service to determine the appropriate type and location
of mailboxes. Multi-family residential developments shall provide a solid overhead structure for
mailboxes with adequate lighting. The final location of the mailboxes and the design of the
overhead structure shall be subject to City Planner review and approval prior to the issuance of
building permits.
APPLICANT SHALL CONTACT THE BUILDING AND SAFETY DIVISION,(909)477-2710, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
NOTE: ANY REVISIONS MAY VOID THESE REQUIREMENTS AND NECESSITATE ADDITIONAL REVIEW(S)
K. General Requirements
1. Submit five complete sets of plans including the following:
a. Site/Plot Plan;
b. Foundation Plan;
C. Floor Plan;
d. Ceiling and Roof Framing Plan;
e. Electrical Plans(2 sets,detached) including the size of the main switch, number and size
of service entrance conductors, panel schedules, and single line diagrams;
f. Plumbing and Sewer Plans, including isometrics, underground diagrams,water and waste
diagram, sewer or septic system location, fixture units, gas piping, and heating and air
conditioning; and
g. Planning Division Project Number(i.e., DRC2003-00241)clearly identified on the outside
of all plans.
2. Submit two sets of structural calculations, energy conservation calculations, and a soils report.
Architect's/Engineer's stamp and "wet" signature are required prior to plan check submittal.
3. Contractors must show proof of State and City licenses and Workers'Compensation coverage to
the City prior to permit issuance.
4. Separate permits are required for fencing and/or walls.
5. Business shall not open for operation prior to posting the Certificate of Occupancy issued by the
Building and Safety Division.
L. Site Development
1. Plans shall be submitted for plan check and approved prior to construction. All plans shall be
marked with the project file number(i.e., DRC2003-00241). The applicant shall comply with the
latest adopted California Codes, and all other applicable codes, ordinances, and regulations in
effect at the time of permit application. Contact the Building and Safety Division for availability of
the Code Adoption Ordinance and applicable handouts.
2. Prior to issuance of building permits for a new residential project or major addition,the applicant _/_J_
shall pay development fees at the established rate. Such fees may include,but are not limited to:
City Beautification Fee, Park Fee, Drainage Fee,Transportation Development Fee, Permit and
Plan Check Fees,and School Fees. Applicant shall provide a copy of the school fees receipt to
the Building and Safety Division prior to permit issuance.
SC-07-03 5
Project No. DRC2003-00241
Completion Date
3. Street addresses shall be provided by the Building and Safety Official after tract/parcel map
recordation and prior to issuance of building permits.
4. Construction activity shall not occur between the hours of 8:00 p.m. and 6:30 a.m. Monday
through Saturday, with no construction on Sunday or holidays.
M. New Structures
1. Provide compliance with the California Building Code (CBC) for property line clearances
considering use, area, and fire-resistiveness.
2. Provide compliance with the California Building Code for required occupancy separations.
3. Roofing material shall be installed per the manufacturer's "high wind" instructions.
N. Grading
1. Grading of the subject property shall be in accordance with California Building Code,City Grading
Standards, and accepted grading practices. The final grading plan shall be in substantial
conformance with the approved grading plan.
2. A soils report shall be prepared by a qualified engineer licensed by the State of California to
perform such work.
3. A geological report shall be prepared by a qualified engineer or geologist and submitted at the
time of application for grading plan check.
4. The final grading, appropriate certifications and compaction reports shall be completed,
submitted, and approved by the Building and Safety Official prior to the issuance of building
permits.
5. A separate grading plan check submittal is required for all new construction projects and for
existing buildings where improvements being proposed will generate 50 cubic yards or more of
combined cut and fill. The grading plan shall be prepared, stamped,and signed by a California
registered Civil Engineer.
APPLICANT SHALL CONTACT THE ENGINEERING DIVISION, (909) 477-2740, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
O. Dedication and Vehicular Access
1. Rights-of-way and easements shall be dedicated to the City for all interior public streets,
community trails, public paseos,public landscape areas,street trees,traffic signal encroachment
and maintenance, and public drainage facilities as shown on the plans and/or tentative map.
Private easements for non-public facilities (cross-lot drainage, local feeder trails, etc.) shall be
reserved as shown on the plans and/or tentative map.
2. Corner property line cutoffs shall be dedicated per City Standards.
3. All existing easements lying within future rights-of-way shall be quit-claimed or delineated on the
final map.
4. Easements for public sidewalks and/or street trees placed outside the public right-of-way shall be
dedicated to the City.
P. Street Improvements
1. All public improvements(interior streets,drainage facilities,community trails,paseos, landscaped
areas, etc.) shown on the plans and/or tentative map shall be constructed to City Standards.
Interior street improvements shall include, but are not limited to,curb and gutter,AC pavement,
drive approaches, sidewalks, streetlights, and street trees.
SC-07-03 6
Project No. DRC2003-00241
Completion Date
2. Improvement Plans and Construction:
a. Street improvement plans, including street trees,street lights,and intersection safety lights
on future signal poles, and traffic signal plans shall be prepared by a registered Civil
Engineer and shall be submitted to and approved by the City Engineer. Security shall be
posted and an agreement executed to the satisfaction of the City Engineer and the City
Attorney guaranteeing completion of the public and/or private street improvements,prior to
final map approval or the issuance of building permits, whichever occurs first.
b. Prior to any work being performed in public right-of-way, fees shall be paid and a
construction permit shall be obtained from the City Engineer's Office in addition to any
other permits required.
C. Pavement striping,marking,traffic signing,street name signing,traffic signal conduit,and
interconnect conduit shall be installed to the satisfaction of the City Engineer.
d. Signal conduit with pull boxes shall be installed with any new construction or reconstruction
project along major or secondary streets and at intersections for future traffic signals and
interconnect wiring. Pull boxes shall be placed on both sides of the street at 3 feet outside
of BCR, ECR, or any other locations approved by the City Engineer
Notes:
1) Pull boxes shall be No.6 at intersections and No.5 along streets,a maximum of 200
feet apart, unless otherwise specified by the City Engineer.
2) Conduit shall be 3-inch (at intersections) or 2-inch (along streets) galvanized steel
with pull rope or as specified.
e. Handicapped access ramps shall be installed on all corners of intersections per City
Standards or as directed by the City Engineer.
f. Existing City roads requiring construction shall remain open to traffic at all times with
adequate detours during construction. Street or lane closure permits are required. A cash
deposit shall be provided to cover the cost of grading and paving,which shall be refunded
upon completion of the construction to the satisfaction of the City Engineer.
g. Concentrated drainage flows shall not cross sidewalks. Under sidewalk drains shall be
installed to City Standards, except for single family residential lots.
h. Street names shall be approved by the City Planner prior to submittal for first plan check.
3. Street trees, a minimum of 15-gallon size or larger, shall be installed per City Standards in
accordance with the City's street tree program.
4. Install street trees per City street tree design guidelines and standards as follows. The completed
legend and construction notes shall appear on the title page of the street improvement plans.
Where public landscape plans are required,tree installation in those areas shall be per the public
landscape improvement plans.
The City Engineer reserves the right to adjust tree species based upon field conditions and other
variables. For additional information, contact the Project Engineer.
Min.
Grow
Street Name Botanical Name Common Name Space Spacing Size' Qty.
SEE ATTACHED SEE ATTACHED SEE ATTACHED
'TREES SHALL BE 15-GALLON SIZE UNLESS OTHERWISE APPROVED.
SC-07-03 7
Project No. DR02003-00241
Completion Date -
Construction Notes for Street Trees:
1) All street trees are to be planted in accordance with City standard plans.
2) Prior to the commencement of any planting,an agronomic soils report shall be furnished to
the City inspector. Any unusual toxicities or nutrient deficiencies may require backfill soil
amendments, as determined by the City inspector.
3) All street trees are subject to inspection and acceptance by the Engineering Division.
4) Street trees are to be planted per public improvement plans only.
5. Intersection line of sight designs shall be reviewed by the City Engineer for conformance with
adopted policy. On collector or larger streets, lines of sight shall be plotted for all project
intersections, including driveways. Local residential street intersections and commercial or
industrial driveways may have lines of sight plotted as required.
Q. Public Maintenance Areas
1. A signed consent and waiver form to join and/or form the appropriate Landscape and Lighting
Districts shall be filed with the City Engineer prior to final map approval or issuance of building
permits whichever occurs first. Formation costs shall be borne by the developer.
2. All required public landscaping and irrigation systems shall be continuously maintained by the
developer until accepted by the City.
R. Drainage and Flood Control
1. A final drainage study shall be submitted to and approved by the City Engineer prior to final map
approval or the issuance of building permits,whichever occurs first. All drainage facilities shall
be installed as required by the City Engineer.
2. Adequate provisions shall be made for acceptance and disposal of surface drainage entering the
property from adjacent areas.
3. Trees are prohibited within 5 feet of the outside diameter of any public storm drain pipe measured
from the outer edge of a mature tree trunk.
4. Public storm drain easements shall be graded to convey overflows in the event of a blockage in a
sump catch basin on the public street.
S. Utilities
1. Provide separate utility services to each parcel including sanitary sewerage system,water,gas,
electric power, telephone, and cable TV (all underground) in accordance with the Utility
Standards. Easements shall be provided as required.
2. The developer shall be responsible for the relocation of existing utilities as necessary.
3. Water and sewer plans shall be designed and constructed to meet the requirements of the
Cucamonga County Water District(CCWD), Rancho Cucamonga Fire Protection District,and the
Environmental Health Department of the County of San Bernardino. A letter of compliance from
the CCW D is required prior to final map approval or issuance of permits,whichever occurs first.
Such letter must have been issued by the water district within 90 days prior to final map approval
in the case of subdivision or prior to the issuance of permits in the case of all other residential
projects.
4. Approvals have not been secured from all utilities and other interested agencies involved.
Approval of the final parcel map will be subject to any requirements that may be received from
them.
SC-07-03 8
Project No. DRC2003-00241
Completion Date
T. General Requirements and Approvals
1. A non-refundable deposit shall be paid to the City,covering the estimated operating costs for all
new streetlights for the first six months of operation,prior to final map approval or prior to building
permit issuance if no map is involved.
APPLICANT SHALL CONTACT THE POLICE DEPARTMENT, (909) 477-2800, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
U. Security Hardware
1. A secondary locking device shall be installed on all sliding glass doors.
2. One-inch single cylinder dead bolts shall be installed on all entrance doors. If windows are within
40 inches of any locking device, tempered glass or a double cylinder dead bolt shall be used.
3. All garage or rolling doors shall have slide bolts or some type of secondary locking devices.
V. Windows
1. All sliding glass windows shall have secondary locking devices and should not be able to be lifted
from frame or track in any manner.
W. Building Numbering
1. Numbers and the backgrounds shall be of contrasting color and shall be reflective for nighttime
visibility.
APPLICANT SHALL CONTACT THE FIRE SAFETY DIVISION, FIRE PROTECTION PLANNING
SERVICES AT, (909) 477-2770, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS:
SEE ATTACHED
SC-07-03 9
CITY OF RANCHO CUCAMONGA
ENGINEERING DIVISION
STREET TREE REQUIREMENT FORM LAST UPDATED 8/27/01
DATE: 3-25-03 TO: JOE STOFA, ASSOCIATE ENGINEER
COMMENTS PREPARED BY. DAWN ROURK, CONTRACT LANDSCAPE PLAN CHECKER
PROJECT: DRC2003-00241
LOCATION: VICTORIA ARBORS — TR 16314
DESIGN NOTES:
1. STREET TREES ON NEW STREETS ARE TO BE SELECTED FROM THE CITY'S APPROVED STREET TREE LIST, BASED UPON
AVAILABLE PLANTING AREA (TYPICALLY BETWEEN BACK-OF-CURB AND THE SIDEWALK). ESTABLISHED STREETS
SHOULD ALREADY HAVE DESIGNATED TREE SPECIES. CONTACT LAURA BONACCORSI AT 909-477-2740, EXT 4023
FOR INFORMATION.
2. STREET TREES ARE TO BE SHOWN ON STREET OR OTHER PUBLIC IMPROVEMENT PLANS SIGNED BY THE CITY
ENGINEER,AND CONSTRUCTED PER THE SAME-
3.
AME3. STREET TREES SHOWN ON PLANNING DIVISION SUBMITTALS ARE CONCEPTUAL ONLY
4. INTERIOR STREETS WILL BE REQUIRED TO SELECT DECIDUOUS TREES FOR EAST-WEST STREETS AND EVERGREEN
TREES FOR NORTH-SOUTH STREETS FROM THE CITY'S APPROVED STREET TREE LIST. WIND-PRONE AREAS MAY BE
REQUIRED TO UTILIZE A MORE DECIDUOUS PALETTE.
5. INDICATED SPACINGS AND SIZESARE REQUIREMENTS FOR CITY-MAINTAINED TREES ONLY. WHERE THE TREE
CONCEPT GOES BEYOND AREAS OF INFLUENCE NEAR PUBLIC IMPROVEMENTS AND/OR ANY CITY MAINTENANCE
EASEMENT,SPACINGS AND SIZES WILL BE PER THE ON-SITE PLANS APPROVED BY THE PLANNING DIVISION. ON-SITE
AND OFFSITE PLANS SHALL BE COORDINATED.
6. STREET IMPROVEMENT PLANS SHALL REFLECT THE LEGEND AND NOTES INDICATED BELOW. IN SOME CASES,WHEN
DETAILS ABOUT PARKWAY SIZES OR UTILITIES ARE UNAVAILABLE AT THE TIME OF CONDITIONING,OPTIONS ARE
PROVIDED FOR VARIOUS SITUATIONS. IT IS THE DESIGNER'S RESPONSIBILITY TO ASCERTAIN THE CONTEXT OF THE
TREE PLANTING,SELECT THE APPROPRIATE TREE OPTION,AND OMIT ANY ERRONEOUS INFORMATION ON THE FINAL
LEGEND.
7. STREET IMPROVEMENT PLANS SHALL REFLECT A LINE ITEM WITHIN THE CONSTRUCTION LEGEND TO STATE:
STREET TREES SHALL BE INSTALLED PER THE NOTES AND LEGEND ON SHEET? (TYPICALLY SHEET 1)
f$� EET NAM �, O'fANICA sNA " ' 000 0 NAMEWf lk `MSN tiW {S fCIN
f;'��wi..nx ,...t; ._..�A�. .,, k �LS?Lr "ir p`: .'. "k1��31 1�v.
PROVIDE STREET SELECT APPROPRIATE TREE FROM THE APPROVED STREET TREE LIST FOR RANCHO I FILL IN
NAME CUCAMONGA. LIST EACH STREET AS A SEPARATE LINE ITEM WITHIN THIS LEGEND.
CONSTRUCTION NOTES FOR STREET TREES:
1. ALL STREET TREES ARE TO BE PLANTED IN ACCORDANCE WITH CITY STANDARD PLANS.
2. PRIOR TO THE COMMENCEMENT OF ANY PLANTING, AN AGRONOMIC SOILS REPORT SHALL BE
FURNISHED TO THE CITY INSPECTOR. ANY UNUSUAL TOXICITIES OR NUTRIENT DEFICIENCIES MAY
REQUIRE BACKFILL SOIL AMENDMENTS, AS DETERMINED BY THE CITY INSPECTOR.
3. ALL STREET TREES ARE SUBJECT TO INSPECTION AND ACCEPTANCE BY THE ENGINEERING
DIVISION.
1. STREET TREES ARE TO BE PLANTED PER PUBLIC IMPROVEMENT PLANS ONLY.
FIRE PROTECTION DISTRICT
FIRE SAFETY DIVISION
STANDARD CONDITIONS
FD PLAN REVIEW#: DRC2003-00241
PROJECT#: DRC2003-00241
PROJECT NAME: Tract 16314
DATE: May 16 2003
PLAN TYPE: SFR
APPLICANT NAME: Standard Pacific/Victoria Arbors
OCCUPANCY CLASS: Group R-3
FLOOR AREA(S): Up to 4500 square feet inc. garage
TYPE CONSTRUCTION: Type V
FIRE PROTECTION
SYSTEM REQUIRED: None
LOCATION: Day Creek and Church
FD REVIEW BY: Tim Fejeran, Fire Inspector
PLANNER: Doug Fenn
ALL OF THE FOLLOWING STANDARD CONDITIONS APPLY TO YOUR PROJECT.
APPLICANT SHALL CONTACT THE FIRE SAFETY DIVISION, (909) 477-2770, TO
VERIFY COMPLIANCE WITH THE FOLLOWING:
RANCHO CUCAMONGA FIRE DISTRICT- STANDARD CONDITIONS & REQUIREMENTS —
General, Procedural, Technical, or Operational Information that shall be Included,
Corrected, or Completed as noted below. The following is applicable to the above
project.
FSC-1 General Requirements for Public and Private Water Supply
1. General Guidance for Fire Hydrants: The following provides general guidance for the spacing and
location of fire hydrants. Remember these are the maximum permitted distances between fire hydrants:
a. The maximum distance between fire hydrants in single-family residential projects is 500-feet. No
portion of the exterior wall facing the addressed street shall be more than 250-feet from an
approved fire hydrant. For cul-de-sacs the distance shall not exceed 200 ft.
b. Fire hydrants are to be located:
1. At the entrance(s) to a project from the existing public roadways. This includes subdivisions
and industrial parks.
2. At intersections.
3. On the right side of the street, whenever practical and possible.
4. As required by the Fire Safety Division to meet operational needs.
5. The location of fire hydrants is based upon the operational needs of the Fire District to control
a fire.
6. Fire hydrants shall be located a minimum of forty(40) feet from any building.
Contact the Fire Safety Division 909 477-2770
2. Minimum Fire Flow: The required fire flow for this project is 1750 gallons per minute at a minimum
residual pressure of 20 pounds per square inch. This requirement is made in accordance with Fire Code
Appendix III-A, as amended. Please see 'Water Availability' attachment for required verification of fire
flow availability for the proposed project. Contact the Fire Safety Division (909) 477-2770
FSC-7 Single-family Residential Sales Models
1. Minimum Access and Water: Residential sales model homes require approved Fire District vehicle access
and water supply from a public or private water main system.
PRIOR TO ISSUANCE OF BUILDING PERMITS- Complete the following-
1.
ollowing:1. Public Fire Hydrants: Prior to issuance of any building permit, the applicant shall submit a plan
showing the locations of all new public fire hydrants for the review and approval by the Fire District
and the Water District. On the plan show all existing fire hydrants within a 600-foot radius of the
project. Contact the Fire Safety Division (909)477-2770
2. Public Installation: All required public fire hydrants shall be installed, flushed, and operable prior to
delivering any combustible building materials on-site (i.e., lumber, roofing materials, etc.). Water
District personnel shall inspect the installation and witness hydrant flushing. The builder/developer
shall submit a copy of the Water District inspection report to the Fire Safety Division. Contact Water
District to schedule testing.
PRIOR TO OCCUPANCY OR FINAL INSPECTION- Complete the following:
1. Hydrant Markers: All fire hydrants shall have a blue reflective pavement marker indicating the fire
hydrant location on the street or driveway in accordance with Rancho Cucamonga Fire Protection
District and City of Rancho Cucamonga Engineering Standard Plan 134, "Installation of Reflective
Hydrant Markers." On private property these markers are to be maintained in good condition by the
property owner. Contact Building and Safety/Fire Construction Services (909) 477-2713.
2. Address Single-family: New single-family dwellings shall post the address with minimum 4-inch
numbers on a contrasting background. The numbers shall be internally or externally illuminated during
periods of darkness. The numbers shall be visible from the street. When building setback from the
public roadway exceeds 100 feet, additional 4-inch numbers shall be displayed at the property entry.
Fire District Forms and Letters
Note: If these conditions are part of the final Standard Conditions issued by the Planning Division referenced
Fire District forms and letters are not included. Contact the Fire Safety Division for copies of forms or letters.The
forms and letter are also found in previously issued Fire District comments.
Fire District Review Letter(P&E)-Template
SL 10/31/02 Revision