HomeMy WebLinkAbout2364W f, 01 CONSTRUCTION NOTES UNLESS OTHERWISE SPECIFIED ON THE WORKING DRAWING WHICH FORMS A PART OF THE SPECIFICATION, THE CONTRACTOR /DEVELOPER SHALL FURNISH THE FOLLOWING ITEMS AT NO COST TO THE CITY OF RANCHO CUCAMONGA. THE ENGINEER HAS ATTEMPTED TO CORRECTLY SHOW ALL EXISTING UTILITIES AND SUBSTRUCTURES IN THE VICINITY OF THE WORK, BUT DOES NOT GUARANTEE THERE ARE NO OTHER SUBSTRUCTURES IN THE AREA. FAILURE OF THE ENGINEER TO SHOW ALL SUBSTRUCTURES IN THEIR CORRECT LOCATION WILL NOT BE A BASIS FOR A CLAIM FOR EXTRA WORK, AND THE CONTRACTOR SHALL BE RESPOSNBLE FOR ALL DAMAGES TO SUBSTRUCTURES WHETHER SHOWN OR NOT. 1. CONDUIT- A. MINIMUM COVER IN STREET OR PARKWAY IS 30` BELOW GUTTER GRADE, UNLESS NOTED OTHERWISE. B. MINIMUM COVER ON PRIVATE PROPERTY IS 30" BELOW FINISHED GRADE, UNLESS NOTED OTHERWISE. C. CONTRACTOR IS TO FURNISH AND INSTALL APPROVED CONDUIT TO CITY SPECIFICATIONS PER UGS- 100.1, 110 AND 120. D. FOR THE TYPE OF CONDUIT FOR THIS JOB, SEE CITY SPECIFICATIONS. E. CAP ALL MAINLINE CONDUITS AND SERVICE CONDUITS PER CITY SPECIFICATIONS. F. INSTALL BLANK CONDUIT PLUGS IN ALL CONDUITS TERMINATING INTO VAULTS} MANHOLES. PMH'S, SOE'S & ALL CAP LOCATIONS, PER CITY SPECIFICATIONS. G. INSTALL PULL ROPE IN ALL CONDUIT RUNS. PULL ROPE TO BE 3/16' POLYPROPYLENE OR POLYETHYLENE ROPE, BRAIDED OR TWISTED. H. ALL CONDUIT MUST BE MANDRELLED WITH A CITY APPROVED MANDRELL. 2. CONDUIT RADIUS REQUIREMENTS: A. THE MINIMUM RADIUS FOR BENDS ARE: 36" FOR CONDUITS 3" IN DIAMETER OR SMALLER 48" FOR CONDUITS 4" AND 5" IN DIAMETER 60" FOR 6" DIAMETER CONDUIT B: THE MINIMUM RADIUS FOR ALL SWEEPS OF ALL MAINLINE CONDUITS IS 12' -6" (UNLESS NOTED OTHERWISE). 3. EXCAVATION AND BACKFILL: A. WORK AREA SHALL BE CLEARED AND ROUGH GRADED TO WITHIN FOUR INCHES OF FINAL GRADE PRIOR TO INSTALLATION OF CITY CONDUIT OR STRUCTURES. B. ALL EXCAVATIONS SHALL BE IN ACCORDANCE WITH THE CALIFORNIA STATE CONSTRUCTION SAFETY ORDERS (WHEN APPLICABLE), CITY SPECIFICATIONS, AND ALL GOVERNING LOCAL ORDINANCES. C. EACH TRENCH TO BE A UNIFORM DEPTH BELOW FINAL GRADE PRIOR TO INSTALLATION OF CITY CONDUIT OR STRUCTURES. D. SACKFILL SHALL BE PROVIDED BY THE CONTRACTOR FOR ALL EXCAVATIONS AND SHALL INCLUDE CRUSHED ROCK, CONCRETE, AND /OR IMPORTED BACKRLL, WHEN REQUIRED. E. BACKFILL WITH A MINIMUM OF ONE SACK PER YARD SAND CEMENT SLURRY AROUND AND OVER VAULTS AND MANHOLES AND AROUND PMH'S WITHIN ONE FOOT OF FINISHED GRADE. F. BACKFILL, PER AGENCY SPECIFICATIONS, SHALL IMMEDIATELY FOLLOW SUBSTRUCTURE INSTALLATION. AT NO TIME SHALL CABLE BE LEFT EXPOSED OVER 24 HOURS. G. N0 ROCKS ARE ALLOWED WITHIN 12 INCHES OF DIRECT— BURIED CABLES OR ANY CONDUIT WITHOUT CONCRETE ENCASEMENT. NATIVE BACKFILL CAPABLE OF PASSING THROUGH A ONE —HALF INCH MESH SCREEN SHALL BE CONSIDERED TO BE "ROCK FREE ". IF EXISTING BACKFILL DOES NOT PASS THROUGH A 1/2" SCREEN. PLACE IMPORTED SAND 3" BELOW AND 12" ABOVE CITE CABLES. AFTER THIS POINT, NO ROCKS LARGER THAN 12" DIAMETER ARE PERMITTED. H. ALL BACKFILL SHALL BE COMPACTED TO MEET OR EXCEED LOCAL: ORDINANCES OR OTHER REQUIREMENTS. IT SHALL BE PLACED IN A MANNER THAT WILL NOT DAMAGE THE CONDUIT OR SUBSTRUCTURE OR ALLOW FUTURE SUBSIDENCE OF THE TRENCH OR STRUCTURES.. 4. PAVING: REPAVING, WHERE REQUIRED. SHALL BE PLACED IN SUCH A MANNER THAT INTERFERENCE WITH TRAFFIC, INCLUDING PEDESTRIAN TRAFFIC, WILL BE KEPT TO A MINIMUM. THE CONTRACTOR SHALL ESTABLISH A PROGRAM OF REPAVING ACCEPTABLE TO THE MUNICIPALITY, COUNTY, OR OTHER AUTHORITY HAVING JURISDICTION AND WHICH IS ACCEPTABLE TO CITY. 5. STRUCTURES: A. ALL SUBSTRUCTURES SHALL BE CONSTRUCTED OR INSTALLED TO CITY SPECIFICATIONS, B. INSTALL PROTECTION BARRIERS WHEN REQUIRED IN AREAS EXPOSED TO TRAFFIC, PER CITY INSPECTOR. C. ALL CONDUIT LINES AND CONCRETE FLOORED SUBSTRUCTURES SHALL BE WATER TIGHT. D. ALL GROUNDING MATERIALS SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR. E. CONTRACTOR TO PROVIDE SUBSTRUCTURE ENCLOSURE WALL DETAILS TO CITY INSPECTOR FOR APPROVAL PRIOR TO INSTALLATION. 6. RETAINING WALLS: WHEN REQUIRED, RETAINING WALLS SHALL BE PROVIDED BY THE CONTRACTOR. WALLS ARE REQUIRED WHEREVER GRADE RISES MORE THAN 18 INCHES ABOVE THE STRUCTURE OR 24" ABOVE THE PAD SURFACE AT A DISTANCE OF 5 FEET FROM THE SAME, OR IN AREAS SUBJECT TO EROSION. DESIGN AND INSTALLATION MUST COMPLY WITH LOCAL BUILDING ORDINANCES- REFER TO CITY INSPECTOR FOR TYPICAL SPACE REQUIREMENTS. 7. PERMITS: ALL PERMITS NECESSARY FOR EXCAVATION SHALL BE PROVIDED BY THE CONTRACTOR. 8. ACCESS: HEAVY TRUCK ACCESS SHALL BE MAINTAINED TO EQUIPMENT LOCATIONS. STRUCTURES MUST BE CLEAR OF ALL APPURTENANCES THAT WOULD OBSTRUCT THE LOADING OR UNLOADING OF EQUIPMENT. 9. SERVICES: A. METERS AND SERVICES SHALL COMPLY WITH CITY SERVICES REQUIREMENTS. B. WIRING MUST BE IN ACCORDANCE WITH APPLICABLE LOCAL. ORDINANCES AND APPROVED BY LOCAL INSPECTION AUTHORITIES. 10. LOCATION: A. THE LOCATION OF EXCAVATIONS AND STRUCTURES FOR CITY SHALE. BE AS SHOWN ON THE WORKING DRAWING. NO DEVIATION FROM THE PLANNED LOCATIONS WILL BE PERMITTED UNLESS APPROVED BY THE CITY INSPECTOR. S. ACTUAL LOCATION OF OBSTRUCTIONS, STORM DRAINS, AND /OR OTHER FOREIGN UTILITIES TO BE THE RESPONSIBILITY OF THE CONTRACTOR. 11. CONTRACTOR IS TO VERIFY LOCATION AND WIDTHS OF ALL SIDEWALKS AND DRIVEWAYS PRIOR TO STREET LIGHT INSTALLATION. WITH THE APPROVED STREET IMPROVEMENT PLANS, APPROVED STREET LIGHT PLANS AND THE ACTUAL FIELD CONDITIONS. 12. SURVEY: SURVEYING OF STREET IMPROVEMENTS SHALL BE PERFORMED BY CONTRACTOR, PROPERTY CORNERS, LOT LINES, FINISHED GRADE, ETC., NECESSARY FOR THE INSTALLATION OF UNDERGROUND FACILITIES MUST BE COMPLETED AND MARKERS OR STAKES PLACED PRIOR TO THE START OF THE INSTALLATION. IN ADDITION, CONTRACTOR SHALL MAINTAIN THE MARKERS DURING THE INSTALLATION AND INSPECTION BY INSPECTION BY AGENCY. GRADE AND PROPERTY LINE STAKES MUST SHOW ANY OFFSET MEASUREMENTS.. 13, COORDINATION AND SUPERVISION: THE CONTRACTOR SHALL PROVIDE SUPERVISION OVER AND COORDINATION AMONG THE VARIOUS CONTRACTORS WORKING WITHIN THE DEVELOPMENT IN ORDER TO PREVENT DAMAGE TO CITY FACILITIES. HE IS RESPONSIBLE FOR THE COST OF REPAIRS, RE- PLACEMENT, RELOCATION, OR OTHER CORRECTIONS TO CITY FACILITIES MADE NECESSARY BY HIS FAILURE TO PROVIDE SUPERVISION OR TO OTHERWISE COMPLY WITH THESE SPECIFICATIONS. 14. TELEPHONE AND OTHER UTILITY REQUIREMENTS: THE DRAWING PREPARED FOR THIS JOB MAY ALSO COVER THE FACILITIES TO BE INSTALLED FOR THE TELEPHONE COMPANY AND /OR OTHER UTILITY. ANY QUESTIONS CONCERNING DETAILS OF THEIR INSTALLATION SHOULD BE REFERRED TO THE COMPANY CONCERNED. 16. WARRANTY: CONTRACTOR EXPRESSLY REPRESENT AND WARRANT THAT ALL WORK PERFORMED AND ALL MATERIAL USED IN MEETING CONTRACTOR'S OBLIGATIONS HEREIN ARE FREE FROM DEFECTS IN WORKMANSHIP AND ARE IN CONFORMITY WITH AGENCY REQUIREMENTS. THIS WARRANTY SHALL COMMENCE UPON RECEIPT BY CONTRACTOR OF CITY'S FINAL ACCEPTANCE AND SHALL EXPIRE ONE YEAR FROM THAT DATE. CONTRACTOR AGREES TO PROMPTLY CORRECT TO THE CITY'S SATISFACTION AND THAT OF ANY GOVERNMENTAL AGENCY HAVING JURISDICTION AND AT CONTRACTOR'S EXPENSE ANY BREACH OF THIS WARRANTY WHICH MAY BECOME APPARENT THROUGH INSPECTION OR OPERATION OF UNDERGROUND ELECTRIC SYSTEM BY CITY DURING THIS WARRANTY PERIOD. 17. INSPECTION: INSPECTION IS REQUIRED DURING THE CONSTRUCTION PERIOD. A 48 HOUR ADVANCE NOTICE OF INTENT TO START CONSTRUCTION IS REQUIRED FROM THE CONTRACTOR TO THE CITY OF RANCHO CUCAMONGA PHONE:909 -477 -2740 X4018 18. AS— BUILTS: CONTRACTOR RESPONSIBLE TO MAINTAIN AS —BUILT DRAWINGS WHICH ARE TO BE UPDATED DAILY. CONTRACTORS SHALL KEEP AND MAINTAIN TWO COPIES OF THE AS— BUILTS. ONE SET IS FOR THE CONTRACTOR AND THE SECOND SET IS FOR THE CITY INSPECTOR. GENERAL NOTES 1. UNLESS OTHERWISE NOTED, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION„ CURRENT EDITION WITH All. CURRENT SUPPLEMENTS, PUBLISHED DY BUILDING NEWS INC., LOCATED AT 1612 S. CLEMENTINE STREET, ANAHEIM CA AND APPROPRIATE STANDARD DRAWINGS. 2- PRIOR TO BEGINNING ANY WORK, THE CONTRACTOR SHAH OBTAIN A PERMIT FROM THE CITY OF RANCHO CUCAMONGA, OFFICE AT 909 - 477 -2740 x4O18 3. ALL WORK COVERED BY THIS PLAN SHALL BE INSPECTED BY THE CITY ENGINEER. REQUEST FOR INSPECTION SERVICE SHALL BE MADE 24 —HWRS IN ADVANCE AT 909 -477 -2740 x4018 4.48—HOURS PRIOR TO ANY WORK, THE CONTRACTOR SHALL CALL THE UNDERGROUND SERVICE ALERT AT 1 (800) 422 -4133 AND OBTAIN AN INQUIRY IDENTIFICATION NUMBER. 5. ALL MANHOLES SHAM BE ADJUSTED TO FINISHED GRADE IN ACCORDANCE WITH SECTION 301 -1.6 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 6. THE CONTRACTOR SHALL PROTECT AND RESTORE EXISTING UTILITIES AND IMPROVEMENTS AS PER SECTION 5 -1, 5 -2, AND 7 -9 OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL UTILITIES OF EVERY NATURE, WHETHER SHOWN HEREON OR NOT, TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR THE TOTAL EXPENSE NE �DED� BY OPERAntNS CONNECTION WITH PROSECUTION OFT WORK UTILITY OWNERS: CITY OF RANCHO CUCAMONGA 10500 CIVIC CENTER DR RANCHO CUCAMONGA, CA 91729 909 -477 -2740 x4018 RANCHO CUCAMONGA LJ_HILLSI UE R i 1 W LSO AVE C. CL r 1�Q Av r Y -X 19TH Email l " V Q 0� 3 [ N RBC L!h! T L- SHEET NO. DESCRIPTION ------ 1 TITLE SHEET •! �_ _ -- � _ ®_ CIR CIR 4(KB4) ARBORS SUBSTATION (66 12KV) TYPICAL TRENCH DETAILS A CIR MA2) CIR 30CA0 8273 ROCHESTER AVENUE L 3 -s>400 GTR 50(NEW) I RCE woe a 7'xl4'xW RCMU ELECTRIC CABLE PLAN I sb-- = ELBOW ELBOW RCE GM � ,I,IVII -- — Lr�vlt -- 2 3-- am ELBOW �__ __ 3 .,Nw tl 1 1 4 II � - l DC 2 l VC 3�- SM c T we .— _ _ _ _ _ _ — JACK BIENNY DRIU _ RCE Ogg r Va r RCE OM T x4 IMMAN om I 1 -FJ I 1 j.. 1 1� I I I I RCE 0123 Y sTa' swl..c 6- 600A ELBOW RCE 0317 5'XIW6'X7' 6--600A ELBOW 3 41000 710' RCE 0318 5'X10'6'X7' 6 -600A ELBOW VICINITY MAP NOT TO SCALE tih 3 -5' STUB FOR FUTURE ROUTE 3 - #1000 1013' _ - -y 3 -#1000 123'J` 1.. --- 11 -L 0 L.BOW $ 3 -5' STUB 6 FOR FUTURE: FOR FUTURE SHEET INDEX SECTION SHEET NO. DESCRIPTION 1 TITLE SHEET TYPICAL STREET SECTIONS 2 TYPICAL TRENCH DETAILS ARROW ROUTE 3-5 RCMU ELECTRIC CABLE PLAN I RCE 0323 RCE 0324 5'X10'6'X7' 5'XIO'6'X7' I 6 -600A ELBOW 6 -600A ELBOW 3- #10001235' - 3- 41000IU6' RCE 0327 - L 5'Xi0'6`X7' 2 -5' STUB 1 FOR FUTURE �, SURE 2 3 -#1000 256' 3- #1000 3' 24 3- #1000 256' 3-#1000 a n w ro RCE 0321 ` 5 ` 1- PIE -I1CL 1- 6 -600A ELBOW 6 -600A A E ELBOW LEGEND OF CONDUIT SYMBOLS ELECTRIC ND, CONDUIT REVD. SIZE OF CONDUIT -�--- LENGTH OF TRENCH FULL ENCASEMENT IS REQUIRED FOR ALL ELECTRIC CONDUIT SAMPLE OF VENDORS: CONCRETE PRODUCTS Precast concrete Item complete with necking,cover,and inserts may be obtained from any of the following approved manufacturers. JENSEN PRECAST 14221 San Bernardino Ave., Fontana, Calif. 92335 Phone: (909) 350 -4111 UTILITY VAULT CO. 10650 Hemlock Ave., Fontana, Calif. 92335 Phone: (909) 350 -2675 (909) 428 -3700 BID SET 3/10/14 X <FOR 2 OR TRENCH AND REPAIR PAVEMENT PER CITY STANDARD 120 "DUCT SPACING SYSTEM -- CARLON SNAP -LOC OR APPROVED EQUAL .A.B. (PER CITY STANDARDS) .2 SACK CEMENT ENCASEMENT TYPICAL. RCMU ELECTRIC ONLY TRENCH NO SCALE NORTH SOUTH R/W R/W T YPICAL STREET SECTION ARROW ROUTE N. T. S. NORTH R/W SOUTH R/W TYPICAL STREET SECTION ARROW ROUTE (WITHIN THE CALTRANS ROW) N. T. S. POLYMER CONCRETE PAD FOR SURFACE - -MOUNTED TRANSFORMERS, 48''x 54' PAD P -4 APPROXIMATE 3' MIN WORKING WEIGHT -125 LB 3' MIN WORKING CLEARANCE FROM CLEARANCE FROM EDGE OF PAD HOLD -DOWN BRACKET (NON -DOR SIDE) (SEE NOTE 2.) EDGE OF PAD (NON -DOR SIDE) 6'-- 54' CABLE PLACEMENT 18, (SEE FIG. 1 AND FIG. 2) 6' 7' 11' 26' lY 48' Do- 8' MIN WORKING CLEARANCE FROM EDGE OF PAD (DOOR SIDE) 4, 20 PLAN VIEW SEC. CABLE 5RM1P AREA r.- FINAL GRADE, PLACE PAD ON 6' OF 3/4' CRUSHED ROCK (SEE NOTE 3, 5, AND 6.) PRI. CABLES --� 6' END VIEW MINI- PADMOUNT (SEE NOTE 1 AND 7.) (FRONT) FIGURE 1 PRI. 2' CABLES ,.'��`.�' SEC. CABLES FINAL GRADE s � STANDARD PADMOUNT /PME -2 (SEE NOTE 1.) INVERTED 17'x30'x15' FIGURE 2 PLASTIC HANDLOE 6' OF CRUSHED ROCK (3f4' (M /C 655 - 48000) (SEE NOTE 3 AND 5.) -- CONDUITS PER 6' CRUSHED RUCK FIGURE 1 (TYP.) FIGURE 3 (END VIEW W /INVERTED HANDHOLE) LO MANWACTURM NOTES, 1. Pad will be manufactured In accordance with SCE specification PCTP -9 -94 polymer Concrete transformer and Equipment Pads' and meet all requirements for Pad 4. 2. Hold -down brackets to be P -3200 series unistrut (or equal) 2.0 INSTALLATION NOTM 1. Primary and secondary cables for min- pad - mounted transformers should be placed Into the clear opening areas as shown in Figure 1t other transformers use Figure2. The work order drawings will Identify which case Is required. 2. For ground rod Installation see AC 701, 3. Subgrade soil below crushed gravel Is to be mechanically compacted to 85 percent relative compaction unless higher Is required by construction permit. Contractor is responsible for for maintaining proper conduit location after grading. 4. Pad to be placed to proper grade relative to finished curb or other reference elevation and level to within 1/4 Inch. 5. An Inverted handhole, as shown In figure 3, shall be Installed. 6. In known rodent problem areas, place Red! -Crete or liquid asphalt emulsion on the crushed rock around conduits In the cable opening. Install two 1 -Inch diameter PVC pipes through crushed rock as drains before placing Red[ -Crete and protect against becoming clogged. 7. For conduit Installation using Figure 1, a template should be used to locate conduit or CIC. 8. Service conduits shall be seated or plugged when the transformer Is located above a customer's meter panel, per G.O. 128, Rule 31.6. 9. Riser bends shalt be schedule 40 PVC minimum on the primary side. 7/16" x 1' -10" x 5' -1" Protective Barrier Pc '" 0. 5' -1" x 5' -1" Openii Top Sectic 1/2"0 Grounding Inser 3 Ea. End W, 6 Toi 7/8 "0 Pull 2 Ea. End 8 Top and B< Base Approximate Weights Top - 10200 Lbs Base - 12100 Lbs 5'x10' -6 "x7' PME /-Steel Closure Plate 14" x 10" x 1/4" SCALE:1 /4" = 1' -0" 514" x 10'4"' x 711-0111 Cover With ne and Gasket 106 Traffic failable ig Pin mr Manhole Opening i "b Terminators 2 Ea. End Wall ?4 Total Overall Outside Dimensions 6' -3 1/2"W x 11' -7 1 x 8' =0 "H Overall Inside Dimensions 5' -0"W x 10' -6 "L x 7' -0 "H VAULT 514" x 10' -6" x 7' -0" 4' x 5' x 8" Concrete Cover Use Felt Between Cover 4' x 5' x 12" Neck Ring Optional Risers Are Available and Are Positioned Between The Vault and The Neck Ring 2 Ton Swi#tlif 2 Ea. Side W( 4 Tot 4 Ton Swiftlifts 4 Total Top Section 1/2 "0 Grounding Inserts 3 Ea. End Walt 6 Total 4' -0" 7/8 "0 Pull Iron 2 Ea. End Wall Top and Base 8 Total Base Section Approximate Weights Top - -11500 Lbs Base 12100 Lbs 5' -10" SCALE:1 /4" -- 1' -0" dentification Spot Traffic Cover and Frame AFCO A1106 or Equal 5 "0 Terminators 4 Ea. End Wall 8 Total 10 "o Vent 1 Ea. End Wall 2 Total 1/2 *0 i -5000 Plastic Inserts 8 Ea. Side Wall 16 Total 5 ",0 Terminators 12 Ea. End Wall 24 Total Overall Outside Dimensions 6' -1 "W x 11'-7L x 8'-6 3/4 "H Overall Inside Dimensions 5' -0 "W x 10' -6 "L x 7'-0 "H BID SET 3/10/14 Pi 3--1/C 100E sc 3 -1 /C 1000 p3 -1 / , C b z Q C� W Z w I0 U m Q W � W VAULT / PICK —UP POINT ' A" 3-1/C 1000 JCN -12KV SCALE 1 "= 40' GROUND ASSEMBLY HOOKS AND RACKS 6- 600A ELBOW 1013'- 3 -1 /C 1000 JCN- 12KV(TO VAULT NEST) �w J it O Z W J m � W � W m� wW z W Z� U W ~ W Q � BID SET 3/10/14 n a•. ww zW uw �w Q� 11w J O J J J m � W � W (/7 5'x10'6 #x7' PME GROUND ASSEMBLY HOOKS AND RACKS 1- PME --9CL 6-- 600A ELBOW 6- 200A INSULATED RECEPTACLE 242' - 3-1/C 1000 JCN -12KV E C/V IMN r SCALE 1 "= 40' 3/10/14