HomeMy WebLinkAbout04-01 - Resolutions RESOLUTION NO. 04-01
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
RANCHO CUCAMONGA, CALIFORNIA, APPROVING DEVELOPMENT
REVIEW DRC2003-00965 FOR THE DEVELOPMENT OF 23 SINGLE-
FAMILY HOMES ON 13.6 ACRES OF LAND IN THE VERY LOW
RESIDENTIAL DISTRICT (.1-2 DWELLING UNITS PER ACRE), LOCATED
AT THE SOUTHWEST CORNER OF HILLSIDE ROAD AND ARCHIBALD
AVENUE, AND MAKING FINDINGS IN SUPPORT THEREOF -
APN: 1067-571-04, 08, 09, 21, AND 22
A. Recitals.
1. Manning Homes filed an application for the approval of Development Review
DRC2003-00965, as described in the title of this Resolution. Hereinafter in this Resolution, the
subject Development Review request is referred to as "the application."
2. On the 14th day of January 2004, the Planning Commission of the City of Rancho
Cucamonga conducted a meeting on the application and concluded said meeting on that date.
3. All legal prerequisites prior to the adoption of this Resolution have occurred.
B. Resolution.
NOW,THEREFORE, it is hereby found, determined, and resolved by the Planning Commission
of the City of Rancho Cucamonga as follows:
1. This Commission hereby specifically finds that all of the facts set forth in the Recitals,
Part A, of this Resolution are true and correct.
2. Based upon the substantial evidence presented to this Commission during the above-
referenced meeting on January 14, 2004, including written and oral staff reports, this Commission
hereby specifically finds as follows:
a. The application applies to property located on the west side of Archibald Avenue,
between Hillside Road and Wilson Avenue. The property contains the historic Toews Residence and
bam, a partially developed Edison substation, and numerous trees; and
b. The property to the north of the subject site is improved with the historic Demens-
Tolstoy Residence, the property to the west is improved with the historic Grandma Isaac Residence,
and the properties to the south and east consist of single-family tract development; and
C. The site was previously subdivided for 23 lots(Tract 16430)on August 13,2003. In
conjunction with the proposed subdivision, the Planning Commission and Historic Preservation
Commission also approved Landmark Alteration Permit DRC2003-00575 and Tree Removal Permit
DRC2002-00917 and recommended approval of Landmark Designation DRC2003-00574 and Mills
Act Application DRC2003-00576 (subsequently approved by the City Council on September 17,
2003)for the Toews Residence to designate the home a historic landmark and relocate it to Lot 19,
to be created by the proposed tentative tract; and
d. The lot sizes range from 20,140 to 28,185 square feet in size, with an average lot
size of 22,570 square feet; and
PLANNING COMMISSION RESOLUTION NO. 04-01
DRC2003-00965—MANNING HOMES
January 14, 2004
Page 2
e. The home designs meet all Hillside and Development Code standards; and
f. The site will gain access from two cul-de-sac streets from Archibald Avenue.
3. Based upon the substantial evidence presented to this Commission during the above-
referenced meeting and upon the specific findings of facts set forth in paragraphs 1 and 2 above,this
Commission hereby finds and concludes as follows:
a. The proposed project is consistent with the objectives of the General Plan; and
b. The proposed use is in accord with the objectives of the Development Code and the
purposes of the district in which the site is located; and
C. The proposed use is in compliance with each of the applicable provisions of the
Development Code; and
d. The proposed use, together with the conditions applicable thereto, will not be
detrimental to the public health, safety, or welfare or materially injurious to properties or
improvements in the vicinity.
4. On August 13, 2003, a Negative Declaration was adopted by the Planning Commission
for Tentative Tract Map SUBTT16430. The Califomia Environmental Quality Act provides that no
further environmental review or Negative Declaration is required for subsequent projects or minor
revisions to projects within the scope of a previous Negative Declaration.
5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above,
this Commission hereby approves the application subject to each and every condition set forth below
and in the Standard Conditions, attached hereto and incorporated herein by this reference.
Planning Division
1) All Conditions of Approval from Tentative Tract Map SUBTT16430,
Landmark Designation DRC2003-00574, Landmark Alteration Permit
DRC2003-00575, Mills Act Application DRC2003-00576, and Tree
Removal Permit DRC2002-00917 shall apply with approval of this
project.
2) All exterior retaining walls, freestanding walls, and open view fencing
visible to the public shall be made of a decorative material with pilasters
and cap. The pilasters shall have a stone treatment and be a minimum
of 30 inches by 30 inches in size. The final design and location of the
walls, including number of pilasters, shall be subject to the satisfaction
of the City Planner.
Engineering Division
1) All pertinent conditions of Tract Map SUBTT16430 shall apply.
2) The final map for Tract SUBTT16430 shall be recorded prior to the
issuance of building permits.
PLANNING COMMISSION RESOLUTION NO. 04-01
DRC2003-00965— MANNING HOMES
January 14, 2004
Page 3
3) Prior to the issuance of building permits, a Diversion Deposit and
related administrative fees shall be paid for the Construction and
Demolition Diversion Program. The deposit is fully refundable if at least
50 percent of all wastes generated during construction and demolition
are diverted from landfills, and appropriate documentation is provided
to the City. Form CD-1 shall be submitted to the Engineering Division
when the first building permit application is submitted to Building and
Safety. Form CD-2 shall be submitted to the Engineering Division
within 60 days following the completion of the construction and/or
demolition project.
4) Provide a drainage report with the Rough Grading plan submittal to
appropriately size the 'V gutter along the private equestrian trails.
Environmental Mitigation Measures
1) This project shall implement all mitigation measures adopted by
Planning Commission Resolution No. 03-107,approving Tentative Tract
Map SUBTT16430.
6. The Secretary to this Commission shall certify to the adoption of this Resolution.
APPROVED AND ADOPTED THIS 14TH DAY OF JANUARY 2004.
PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA
BY: /a"
Rich Macias, Chairman
ATTEST:
Brad r, S cret
I, Brad Buller, Secretary of the Planning Commission of the City of Rancho Cucamonga, do hereby
certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the
Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning
Commission held on the 14th day of January 2004, by the following vote-to-wit:
AYES: COMMISSIONERS: FLETCHER, MACIAS, McNIEL, McPHAIL, STEWART
NOES: COMMISSIONERS: NONE
ABSENT: COMMISSIONERS: NONE
COMMUNITY DEVELOPMENT
- DEPARTMENT
STANDARD CONDITIONS
PROJECT#: DRC2003-00965
SUBJECT: 23 SINGLE-FAMILY HOMES
APPLICANT: MANNING HOMES
LOCATION: SOUTHWEST CORNER OF HILLSIDE ROAD AND ARCHIBALD AVENUE
ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT.
APPLICANT SHALL CONTACTTHE PLANNING DIVISION,(909)477-2750,FOR COMPLIANCE
WITH THE FOLLOWING CONDITIONS:
A. General Requirements Completion Date
1. The applicant shall agree to defend at his sole expense any action brought against the City, its
agents,officers,or employees,because of the issuance of such approval,or in the alternative,to
relinquish such approval. The applicant shall reimburse the City, its agents, officers, or
employees, for any Court costs and attorney's fees which the City, its agents, officers, or
employees may be required by a court to pay as a result of such action. The City may,at its sole
discretion,participate at its own expense in the defense of any such action but such participation
shall not relieve applicant of his obligations under this condition.
2. Copies of the signed Planning Commission Resolution of Approval No. 04-01, Standard
Conditions, and all environmental mitigations shall be included on the plans (full size). The
sheet(s) are for information only to all parties involved in the construction/grading activities and
are not required to be wet sealed/stamped by a licensed Engineer/Architect.
B. Time Limits
1. Conditional Use Permit, Variance, or Development/Design Review approval shall expire if J_
building permits are not issued or approved use has not commenced within 5 years from the date
of approval. No extensions are allowed.
C. Site Development
1. The site shall be developed and maintained in accordance with the approved plans which include
site plans,architectural elevations,exterior materials and colors,landscaping,sign program,and
grading on file in the Planning Division,the conditions contained herein,and Development Code
regulations.
2. Prior to any use of the project site or business activity being commenced thereon,all Conditions
of Approval shall be completed to the satisfaction of the City Planner.
SC-10-03 1
Project No.DRC2003-00965
Completion Date
3. Occupancy of the facilities shall not commence until such time as all Uniform Building Code and
State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be
submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety Division
to show compliance. The buildings shall be inspected for compliance prior to occupancy.
4. Revised site plans and building elevations incorporating all Conditions of Approval shall be
submitted for City Planner review and approval prior to the issuance of building permits.
5. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for
consistency prior to issuance of any permits (such as grading, tree removal, encroachment,
building, etc.)or prior to final map approval in the case of a custom lot subdivision, or approved
use has commenced, whichever comes first.
6. Approval of this request shall not waive compliance with all sections of the Development Code,all _J_J_
other applicable City Ordinances, and applicable Community or Specific Plans in effect at the
time of building permit issuance.
7. If no centralized trash receptacles are provided,all trash pick-up shall be for individual units with
all receptacles shielded from public view.
8. All ground-mounted utility appurtenances such as transformers, AC condensers, etc., shall be _J_J_
located out of public view and adequately screened through the use of a combination of concrete
or masonry walls, berming,and/or landscaping to the satisfaction of the City Planner. For single-
family residential developments, transformers shall be placed in underground vaults.
9. Street names shall be submitted for City Planner review and approval in accordance with the
adopted Street Naming Policy prior to approval of the final map.
10. All building numbers and individual units shall be identified in a clear and concise manner, —J--/—
including proper illumination.
11. A detailed plan indicating trail widths, maximum slopes, physical conditions,fencing,and weed _J_J_
control, in accordance with City Master Trail drawings,shall be submitted for City Planner review
and approval prior to approval and recordation of the Final Tract Map and prior to approval of
street improvement and grading plans. Developer shall upgrade and construct all trails,including
fencing and drainage devices, in conjunction with street improvements.
a. Local Feeder Trails (i.e., private equestrian easements) shall, at a minimum, be fenced
with two-rail,4-inch lodgepole°peeler"logs to define both sides of the easement;however,
developer may upgrade to an alternate fence material.
b. Local Feeder Trail entrances shall also provide access for service vehicles, such as _J--J_
veterinarians or hay deliveries, including a 12-foot minimum drive approach. Entrance
shall be gated provided that equestrian access is maintained through step-throughs.
C. Local Feeder Trail grades shall not exceed 0.5% at the downstream end of a trail for a
distance of 25 feet behind the public right-of-way line to prohibit trail debris from reaching
the street. Drainage devices maybe required by the Building Official
d. Provide a 24-foot.by 24-foot corral area in the rear yard. Grade access from corral to trail _J_J_
with a maximum slope of 5:1 and a minimum width of 10 feet.
e. For single family residential development within the Equestrian/Rural Overlay District, at __/_J_
least one model home shall be provided with a constructed 24-foot by 24-foot corral with
appropriate fencing.
12. The Covenants, Conditions,and Restrictions(CC&Rs)shall not prohibit the keeping the equine
animals where zoning requirements for the keeping of said animals have been met. Individual lot
owners in subdivisions shall have the option of keeping said animals without the necessity of
appealing to boards of directors of homeowners' associations for amendments to the CC&Rs.
SC-10-03 2
Project No.DRC2003-00965
Completion Date
13. The Covenants, Conditions, and Restrictions (CC&Rs) and Articles of Incorporation of the _J_/
Homeowners'Association are subject to the approval of the Planning and Engineering Divisions
and the City Attorney. They shall be recorded concurrently with the Final Map or prior to the
issuance of building permits, whichever occurs first. A recorded copy shall be provided to the
City Engineer. The Homeowners' Association shall submit to the Planning Division a list of the
name and address of their officers on or before January 1 of each and every year and whenever
said information changes.
14. All parkways, open areas, and landscaping shall be permanently maintained by the property
owner,homeowners'association,or other means acceptable to the City. Proof of this landscape
maintenance shall be submitted for City Planner and City Engineer review and approved prior to
the issuance of building permits.
15. The project contains a designated Historical Landmark. The site shall be developed and
maintained in accordance with Historic Landmark Alteration Permit No. DRC2003-00575. Any
further modifications to the site including, but not limited to, exterior alterations and/or interior
alterations which affect the exterior of the buildings or structures, removal of landmark trees,
demolition, relocation, reconstruction of buildings or structures, or changes to the site, shall
require a modification to the Historic Landmark Alteration Permit subject to Historic Preservation
Commission review and approval.
16. Six-foot decorative block walls shall be constructed along the project perimeter. If a double wall
condition would result, the developer shall make a good faith effort to work with the adjoining
property owners to provide a single wall. Developer shall notify, by mail,all contiguous property
owner at least 30 days prior to the removal of any existing walls/fences along the project's
perimeter.
17. Construct block walls between homes(i.e.,along interior side and rear property lines),rather than
wood fencing for permanence, durability, and design consistency.
18. Access gates to the rear yards shall be constructed from a material more durable than wood
gates. Acceptable materials include, but are not limited to, wrought iron and PVC.
19. For residential development, return walls and corner side walls shall be decorative masonry. Jam_
20. Wood fencing shall be treated with stain, paint, or water sealant.
21. On corner side yards, provide minimum 5-foot setback between walls/fences and sidewalk.
22. Where rock cobble is used, it shall be real river rock. Other stone veneers may be manufactured
products.
D. Building Design
1. All roof appurtenances, including air conditioners and other roof mounted equipment and/or
projections, shall be shielded from view and the sound buffered from adjacent properties and
streets as required by the Planning Division. Such screening shall be architecturally integrated
with the building design and constructed to the satisfaction of the City Planner. Details shall be
included in building plans.
E. Parking and Vehicular Access (indicate details on building plans)
1. Multiple car garage driveways shall be tapered down to a standard two-car width at street.
SC-10.03 3
Project No.DRC2003-00965
Completion Date
F. Landscaping
1. A detailed landscape and irrigation plan,including slope planting and model home landscaping in
the case of residential development, shall be prepared by a licensed landscape architect and
submitted for City Planner review and approval prior to the issuance of building permits or prior
final map approval in the case of a custom lot subdivision.
2. Existing trees required to be preserved in place shall be protected with a construction barrier in
accordance with the Municipal Code Section 19.08.110,and so noted on the grading plans. The
location of those trees to be preserved in place and new locations for transplanted trees shall be
shown on the detailed landscape plans. The applicant shall follow all of the arborist's
recommendations regarding preservation, transplanting, and trimming methods.
3. All private slopes of 5 feet or more in vertical height and of 5:1 or greater slope,but less than 2:1
slope,shall be, at minimum,irrigated and landscaped with appropriate ground cover for erosion
control. Slope planting required by this section shall include a permanent irrigation system to be
installed by the developer prior to occupancy.
4. All private slopes in excess of 5 feet, but less than 8 feet in vertical height and of 2:1 or greater
slope shall be landscaped and irrigated for erosion control and to soften their appearance as
follows: one 15-gallon or larger size tree per each 150 sq.ft.of slope area 1-gallon or larger size
shrub per each 100 sq.ft.of slope area,and appropriate ground cover. In addition,slope banks
in excess of 8 feet in vertical height and 2:1 or greater slope shall also include one 5-gallon or
larger size tree per each 250 sq. ft. of slope area. Trees and shrubs shall be planted in
staggered clusters to soften and vary slope plane. Slope planting required by this section shall
include a permanent irrigation system to be installed by the developer prior to occupancy.
5. For single-family residential development, all slope planting and irrigation shall be continuously
maintained in a healthy and thriving condition by the developer until each individual unit is sold
and occupied by the buyer. Prior to releasing occupancy for those units, an inspection shall be
conducted by the Planning Division to determine that they are in satisfactory condition.
6. Front yard and corner side yard landscaping and irrigation shall be required per the Development
Code. This requirement shall be in addition to the required street trees and slope planting.
7. The final design of the perimeter parkways,walls,landscaping,and sidewalks shall be included in
the required landscape plans and shall be subject to City Planner review and approval and
coordinated for consistency with any parkway landscaping plan which may be required by the
Engineering Division.
8. Landscaping and irrigation systems required to be installed within the public right-of-way on the
perimeter of this project area shall be continuously maintained by the developer.
9. All walls shall be provided with decorative treatment. If located in public maintenance areas,the
design shall be coordinated with the Engineering Division.
10. New windrow planting of Eucalyptus Maculata (Spotted Gum) is required at a ratio of 50 linear
feet per acre. The size,spacing,staking,and irrigation of these trees shall comply with the City's
Tree Preservation Ordinance (RCMC 19.08.100).
G. Environmental
1. Mitigation measures are required for the project. The applicant is responsible for the cost of
implementing said measures, including monitoring and reporting. Applicant shall be required to
post cash, letter of credit, or other forms of guarantee acceptable to the City Planner in the
amount of $719.00 prior to the issuance of building permits, guaranteeing satisfactory
performance and completion of all mitigation measures. These funds maybe used bythe Cityto
retain consultants and/or pay for City staff time to monitor and report on the mitigation measures.
Failure to complete all actions required by the approved environmental documents shall be
considered grounds for forfeit.
SC-10-03 4
Project No.DRC2003-00965
Completion Date
H. Other Agencies
1. The applicant shall contact the U.S. Postal Service to determine the appropriate type and location __J_J_
of mailboxes. Multi-family residential developments shall provide a solid overhead structure for
mailboxes with adequate lighting. The final location of the mailboxes and the design of the
overhead structure shall be subject to City Planner review and approval prior to the issuance of
building permits.
APPLICANT SHALL CONTACT THE BUILDING AND SAFETY DIVISION,(909)477-2710, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
NOTE: ANY REVISIONS MAY VOID THESE REQUIREMENTS AND NECESSITATE ADDITIONAL REVIEW(S)
I. General Requirements
1. Submit five complete sets of plans including the following:
a. Site/Plot Plan;
b. Foundation Plan;
C. Floor Plan;
d. Ceiling and Roof Framing Plan;
e. Electrical Plans (2 sets,detached) including the size of the main switch, number and size
of service entrance conductors, panel schedules, and single line diagrams;
f. Plumbing and Sewer Plans, including isometrics, underground diagrams,water and waste
diagram, sewer or septic system location, fixture units, gas piping, and heating and air
conditioning; and
g. Planning Division Project Number(i.e.,TT#, CUP If, DR#, etc.)clearly identified on the
outside of all plans.
2. Submit two sets of structural calculations, energy conservation calculations, and a soils report.
Architect's/Engineer's stamp and "wet"signature are required prior to plan check submittal.
3. Contractors must show proof of State and City licenses and Workers'Compensation coverage to _J_J
the City prior to permit issuance.,
4. Separate permits are required for fencing and/or walls.
5. Developers wishing to participate in the Community Energy Efficiency Program (CEEP) can
contact the Building and Safety Division staff for information and submittal requirements.
J. Site Development
1. Plans shall be submitted for plan check and approved prior to construction. All plans shall be
marked with the project file number(i.e., DRC2001-00001). The applicant shall comply with the
latest adopted California Codes, and all other applicable codes, ordinances, and regulations in
effect at the time of permit application. Contact the Building and Safety Division for availability of
the Code Adoption Ordinance and applicable handouts.
2. Prior to issuance of building permits for a new residential project or major addition,the applicant
shall pay development fees at the established rate. Such fees may include,but are not limited to:
City Beautification Fee, Park Fee, Drainage Fee,Transportation Development Fee, Permit and
Plan Check Fees,and School Fees. Applicant shall provide a copy of the school fees receipt to
the Building and Safety Division prior to permit issuance.
SC-10-03 5
Project No.DRC2003-00965
Completion Date
3. Street addresses shall be provided by the Building and Safety Official after tract/parcel map
recordation and prior to issuance of building permits.
4. Construction activity shall not occur between the hours of 8:00 p.m. and 6:30 a.m. Monday _/ /_
through Saturday,with no construction on Sunday or holidays.
K. New Structures
1. Provide compliance with the California Building Code (CBC), for property line clearances
considering use, area, and fire-resistiveness.
2. Provide compliance with the California Building Code for required occupancy separations.
3. Roofing material shall be installed per the manufacturer's "high wind" instructions.
L. Grading
1. Grading of the subject property shall be in accordance with California Building Code,City Grading
Standards, and accepted grading practices. The final grading plan shall be in substantial
conformance with the approved grading plan.
2. A soils report shall be prepared by a qualified engineer licensed by the State of California to
perform such work.
3. A geological report shall be prepared by a qualified engineer or geologist and submitted at the
time of application for grading plan check.
4. The final grading, appropriate certifications and compaction reports shall be completed,
submitted, and approved by the Building and Safety Official prior to the issuance of building
permits.
5. In hillside areas, residential developments shall be graded and constructed consistent with the
standards contained in the Hillside Development Regulations Section 17.24.070.
6. A separate grading plan check submittal is required for all new construction projects and for
existing buildings where improvements being proposed will generate 50 cubic yards or more of
combined cut and fill. The grading plan shall be prepared, stamped, and signed by a Califomia
registered Civil Engineer.
APPLICANT SHALL CONTACT THE ENGINEERING DIVISION, (909) 477-2740, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
M. Dedication and Vehicular Access
1. Rights-of-way and easements shall be dedicated to the City for all interior public streets,
community trails,public paseos,public landscape areas,street trees,traffic signal encroachment
and maintenance, and public drainage facilities as shown on the plans and/or tentative map.
Private easements for non-public facilities (cross-lot drainage, local feeder trails, etc.) shall be
reserved as shown on the plans and/or tentative map.
2. Dedication shall be made of the following rights-of-way on the perimeter streets(measured from
street centerline):
33 total feet on Hillside Avenue.
44 total feet on Wilson.
44 total feet on Archibald Avenue.
3. Corner property line cutoffs shall be dedicated per City Standards.
SC-10-03 6
Project No.DRC2003-00965
Completion Date
N. Street Improvements
1. All public improvements(interior streets,drainage facilities,community trails,paseos,landscaped
areas, etc.) shown on the plans and/or tentative map shall be constructed to City Standards.
Interior street improvements shall include, but are not limited to,curb and gutter,AC pavement,
drive approaches, sidewalks, street lights, and street trees.
2. Construct the following perimeter street improvements including, but not limited to:
Curb& A.C. Side- Drive Street Street Comm Median Bike
Street Name Gutter Pvmt walk Appr. Lights Trees Trail Island Trail Other
Archibald Avenue X X X X X X
Wilson Avenue X X X X
Hillside Road X X X X X X
Notes: (a) Median island includes landscaping and irrigation on meter. (b) Pavement
reconstruction and overlays will be determined during plan check. (c) If so marked, sidewalk
shall be curvilinear per Standard 114. (d) If so marked, an in-lieu of construction fee shall be
provided for this item.
3. Improvement Plans and Construction:
a. Street improvement plans, including street trees,street lights,and intersection safety lights
on future signal poles, and traffic signal plans shall be prepared by a registered Civil
Engineer and shall be submitted to and approved by the City Engineer. Security shall be
posted and an agreement executed to the satisfaction of the City Engineer and the City
Attorney guaranteeing completion of the public and/or private street improvements,prior to
final map approval or the issuance of building permits, whichever occurs first.
b. Prior to any work being performed in public right-of-way, fees shall be paid and a
construction permit shall be obtained from the City Engineer's Office in addition to any
other permits required.
C. Pavement striping,marking,traffic signing,street name signing,traffic signal conduit,and
interconnect conduit shall be installed to the satisfaction of the City Engineer.
d. Signal conduit with pull boxes shall be installed with any new construction or reconstruction
project along major or secondary streets and at intersections for future traffic signals and
interconnect wiring. Pull boxes shall be placed on both sides of the street at 3 feet outside
of BCR, ECR, or any other locations approved by the City Engineer
Notes:
1) Pull boxes shall be No.6 at intersections and No.5 along streets,a maximum of 200
feet apart, unless otherwise specified by the City Engineer.
2) Conduit shall be 3-inch (at intersections)or 2-inch (along streets)galvanized steel
with pull rope or as specified.
e. Handicapped access ramps shall be installed on all corners of intersections per City
Standards or as directed by the City Engineer.
f. Existing City roads requiring construction shall remain open to traffic at all times with
adequate detours during construction. Street or lane closure permits are required. A cash
deposit shall be provided to cover the cost of grading and paving,which shall be refunded
upon completion of the construction to the satisfaction of the City Engineer.
g. Concentrated drainage flows shall not cross sidewalks. Under sidewalk drains shall be
installed to City Standards, except for single family residential lots.
SC-10-03 7
Project No.DRC2003-00965
Completion Date
h. Street names shall be approved by the City Planner prior to submittal for first plan check. _/_/_
4. Street trees, a minimum of 15-gallon size or larger, shall be installed per City Standards in
accordance with the Citys street tree program.
5. Install street trees per City street tree design guidelines and standards as follows. The completed
legend and construction notes shall appear on the title page of the street improvement plans.
Where public landscape plans are required,tree installation in those areas shall be per the public
landscape improvement plans.
The City Engineer reserves the right to adjust tree species based upon field conditions and other
variables. For additional information, contact the Project Engineer.
Min.
Grow
Street Name Botanical Name Common Name Space Spacing Size* Qty.
HILLSIDE ROAD Lagerstromemia White Crape Myrtle 3 ft. 20 ft.o.c. 24-inch Fill-in
indica"Natchez" Hybrid box
WILSON AVENUE ,
P.A. less than 8 ft. Lasgerstroemia Crape Myrtle 3 ft. 20 ft.o.c. 24-inch
indica"Muskogee" Hybrid- Lavender box
P.A.greater than 8ft. Cinnamonium Camphor Tree 8 ft. 30 ft.o.c. 15-gal
camphora
ARCHIBALDAVENUE
Foreground Tree Pyrus calleryana Bradford Pear 3 ft. 20 ft.o.c. 15-gal.
P.A. less than 8 ft. "Bradford"
STREET TREES LISTED BELOW ARE FOR LMD PLAN REFERENCE ONLY—NOT TO APPEAR ON
STREET IMPROVEMENT PLANS
ARCHIBALDAVENUE
Background Tree Platanus acerifolia London Plane Tree 8 ft. 30 ft.o.c. 15-gal.
Accent Tree Lagerstmemia Crape Myrtle 3 ft. 20 ft.o.c. 24-inch
indica Hybrid-Dark Pink box
'TREES SHALL BE 15-GALLON SIZE UNLESS OTHERWISE APPROVED.
Construction Notes for Street Trees:
1) All street trees are to be planted in accordance with City standard plans.
2) Prior to the commencement of any planting,an agronomic soils report shall be fumished to
the City inspector. Any unusual toxicities or nutrient deficiencies may require backfill soil
amendments, as determined by the City inspector.
3) All street trees are subject to inspection and acceptance by the Engineering Division.
4) Street trees are to be planted per public improvement plans only.
O. Public Maintenance Areas
1. A separate set of landscape and irrigation plans per Engineering Public Works Standards shall
be submitted to the City Engineer for review and approval prior to final map approval or issuance
of building permits, whichever occurs first. The following landscaped parkways, medians,
paseos, easements, trails or other areas shall be annexed into the Landscape Maintenance
District:Archibald Avenue.
2. Public landscape areas are required to incorporate substantial areas(40%)of mortared cobble or
other acceptable non-irrigated surfaces.
SC-10-03 8
Project No.ORC2003-00965
Completion Date
3. A signed consent and waiver form to join and/or form the appropriate Landscape and Lighting
Districts shall be fled with the City Engineer prior to final map approval or issuance of building
permits whichever occurs first. Formation costs shall be borne by the developer.
4. All required public landscaping and irrigation systems shall be continuously maintained by the
developer until accepted by the City.
\ 5. Parkway landscaping on the following street(s) shall conform to the results of the respective
Beautification Master Plan: Archibald Avenue.
P. Drainage and Flood Control
1. A final drainage study shall be submitted to and approved by the City Engineer prior to final map
approval or the issuance of building permits,whichever occurs first. All drainage facilities shall
be installed as required by the City Engineer.
2. Adequate provisions shall be made for acceptance and disposal of surface drainage entering the
property from adjacent areas.
3. Trees are prohibited within 5 feet of the outside diameter of any public storm drain pipe measured
from the outer edge of a mature tree trunk.
Q. Utilities
1. Provide separate utility services to each parcel including sanitary sewerage system,water,gas,
electric power, telephone, and cable TV (all underground) in accordance with the Utility
Standards. Easements shall be provided as required.
2. The developer shall be responsible for the relocation of existing utilities as necessary.
3. Water and sewer plans shall be designed and constructed to meet the requirements of the
Cucamonga County Water District(CCW D),Rancho Cucamonga Fire Protection District,and the
Environmental Health Department of the County of San Bernardino. A letter of compliance from
the CCW D is required prior to final map approval or issuance of permits,whichever occurs first.
Such letter must have been issued by the water district within 90 days prior to final map approval
in the case of subdivision or prior to the issuance of permits in the case of all other residential
projects.
4. Approvals have not been secured from all utilities and other interested agencies involved.
Approval of the final parcel map will be subject to any requirements that may be received from
them.
R. General Requirements and Approvals
1. A non-refundable deposit shall be paid to the City, covering the estimated operating costs for all
new streetlights for the first six months of operation, prior to final map approval or prior to building
permit issuance if no map is involved.
APPLICANT SHALL CONTACT THE POLICE DEPARTMENT, (909) 477-2800, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
S. Security Hardware
1. A secondary locking device shall be installed on all sliding glass doors.
2. One-inch single cylinder dead bolts shall be installed on all entrance doors. If windows are within
40 inches of any locking device, tempered glass or a double cylinder dead bolt shall be used.
SCA 0-03 9
Project No.DRC2003-00965
Completion Date
3. All garage or rolling doors shall have slide bolts or some type of secondary locking devices.
T. Windows
1. All sliding glass windows shall have secondary locking devices and should not be able to be lifted
from frame or track in any manner.
U. Building Numbering
1. Numbers and the backgrounds shall be of contrasting color and shall be reflective for nighttime
visibility.
APPLICANT SHALL CONTACT THE FIRE SAFETY DIVISION, FIRE PROTECTION PLANNING
SERVICES AT, (909) 477-2770, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS:
SEE ATTACHED
SC-10-03 10
RANCHO CUCAMONGA FIRE DISTRICT
STANDARD CONDITIONS
PROJECT/FILE #: DRC2003-00965 APPLICANT NAME: Archibald Adventures
PROJECT NAME: Alta Loma 23 tract 16430 OCCUPANCY CLASS: Group R-3
LOCATION: Archibald s/o Hillside FLOOR AREA (S): Approx. 4545 sq. ft.
DATE: 12-02-2003 CONSTRUCTION TYPE: Type V-N
PLAN TYPE: SFR tract, public streets FD REVIEW BY: Moises Eskenazi
PLANNER: Warren Morelion ANNEXATION: possible Fire: Non-High Hazard
THE FOLLOWING STANDARD CONDITIONS APPLY TO YOUR PROJECT.
RANCHO CUCAMONGA FIRE DISTRICT- STANDARD CONDITIONS & REQUIREMENTS -
FSC-1 General Requirements for Public and Private Water Supply. Water (fire) plans must be approved by
RCFPD and CCWD prior to permit issuance
1. General Guidance for Fire Hydrants: The following provides general guidance for the spacing and
location of fire hydrants. Remember these are the maximum permitted distances between fire hydrants:
a. The maximum distance between fire hydrants in commercial/industrial projects is 300-feet. No portion
of the exterior wall shall be located more than 150-feet from an approved fire hydrant. For cul-de-sacs
the distance shall not exceed 100-feet.
b. The maximum distance between fire hydrants in multi-family residential is 400-feet. No portion of the
exterior wall shall be located more than 200-feet from an approved fire hydrant. For cul-de-sacs the
distance shall not exceed 150-feet.
C. The maximum distance between fire hydrants in single-family residential projects is 500-feet. No
portion of the exterior wall facing the addressed street shall be more than 250-feet from an approved
fire hydrant. For cul-de-sacs the distance shall not exceed 200 ft.
d. For single-family residential projects in the designated Hazardous Fire Area the maximum distance
between fire hydrants is 400-feet. No portion of the exterior wall facing the addressed street shall be
more than 200-feet from an approved fire hydrant. For cul-de-sacs the distance shall not exceed 150
ft.
e. Fire hydrants are to be located:
i. At the entrance(s) to a project from the existing public roadways. This includes subdivisions and
industrial parks.
ii. At intersections.
iii. On the right side of the street, whenever practical and possible.
iv. As required by the Fire Safety Division to meet operational needs.
V. The location of fire hydrants is based upon the operational needs of the Fire District to control a
fire.
vi. Fire hydrants shall be located a minimum of 40 feet from any building.
2. Minimum Fire Flow: The required fire flow for this-project is 1750 gallons per minute at a minimum residual
pressure of 20 pounds per square inch. This requirement is made in accordance with Fire Code Appendix
III-A, as amended.
3. Hydrants Used to Supply Fire Flow: Public fire hydrants located within a 500-foot radius of the proposed
project may be used to provide the required fire flow subject to Fire District review and approval. Private fire
hydrants on adjacent property shall not be used to provide required fire flow.
4. Show Existing Fire Hydrants and Mains: Existing fire hydrants and mains within 600-feet of the project
shall be shown on the water plan submitted for review and approval. Include main size.
FSC-2 Private(On-Site)Water and/or Fire Sprinkler Underground Plans for Fire Protection
1. Number of Fire Hydrants: Provide one fire hydrant for each 1000 gpm of required fire flow or fraction
thereof, subject to standard spacing and distribution requirements.
FSC-4 Fire District Site Access-Technical Comments
1. Access Roadways Defined: Fire District access roadways include public roads, streets, and highways, as
well as private roads, streets, drive aisles and designated fire lanes.
2. Private Roadways and Fire Lanes:The minimum specifications for private fire district access roadways are:
a. The minimum unobstructed width is 26-feet.
b. The inside tum radius shall be 20-feet.
C. The outside turn radius shall be not less than 504eet.
d. The minimum radius for cul-de-sacs is 45-feet.
e. The minimum vertical clearance is 14 feet, 6 inches.
I. At any private entry median,the minimum width of traffic lanes shall be 20-feet.
g. The angle of departure and approach shall not exceed 9 degrees or 20 percent.
h.. The maximum grade of the driving surface shall not exceed 12%.
i. Support a minimum load of 70,000 pounds gross vehicle weight (GVW).
3. Vegetation: Trees and shrubs planted in any median shall be kept trimmed to a minimum of 14-feet, 6- inches
from the ground up,so as not to impede fire vehicles.
Note: Carefully review the items below. There may be significant impact on the proposed project. Italicized text
indicates a Rancho Cucamonga Fire District amendment.
FSC-12 Plan Submittal Required Notice
Required plans shall be submitted and approved prior to construction in accordance with 2000/2001 Building, Fire,
Mechanical, and Plumbing Codes; 1999 Electrical Code; Health and Safety Code; Public Resources Code; and
RCFPD Ordinances FD15 and FD39, Guidelines and Standards.
PRIOR TO ISSUANCE OF BUILDING PERMITS- Building permits will not be issued until the
water (fire) plans are submitted and approved by CCWD and Fire Construction Services
Complete the following:
1. Private/On-site Fire Hydrants: Prior to the issuance of any building permit, the applicant shall submit
construction plans, specifications, flow test data and calculations for the private water main system for
review and approval by the Fire District. Plans and installation shall comply with Fire District standards.
2. Private Fire Hydrants/On-site Installation: All private on-site fire hydrants shall be installed, flushed, and
operable prior to delivering any combustible building materials on-site (i.e., lumber, roofing materials, etc.).
A representative of Fire Construction Services shall inspect the installation and witness hydrant flushing.
The builder/developer shall submit final test and inspection report to the Fire Safety Division.
3. Public Fire Hydrants: Prior to issuance of any building permit, the applicant shall submit a plan showing the
locations of all new public fire hydrants for the review and approval by the Fire District and the Water District.
On the plan show all existing fire hydrants within a 600-foot radius of the project
4. Public Installation: All required public fire hydrants shall be installed, flushed, and operable prior to
delivering any combustible building materials on-site (i.e., lumber, roofing materials, etc.). Water District
personnel shall inspect the installation and witness hydrant flushing. The builder/developer shall submit a
copy of the Water District inspection report to the Fire Safety Division. Contact Water District to schedule
testing.
PRIOR TO OCCUPANCY OR FINAL INSPECTION- Complete the following:
1. Private Fire Hydrants- Final Acceptance: For the purpose of final acceptance, an additional test of the on-
site fire hydrants shall be conducted by the builder/developer in the presence of the Water District or Fire
Construction Services, as appropriate. The builder/developer shall submit the final test report to the Fire
Safety Division.
2. Construction Access: Fire District access, a minimum 26-feet in width and 14-feet, 6-inches minimum clear
height shall be provided. These minimum clearances shall be maintained free and clear of any obstructions at
all times, in accordance with Fire District Standards.
3. Phased Construction: Each phase shall be provided with approved Fire District access roadways. Dead-
end roadways shall not exceed the maximum permitted by the Fire Code or Fire District standards.