HomeMy WebLinkAbout08-10 - Resolutions RESOLUTION NO. 08-10
A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF
RANCHO CUCAMONGA, CALIFORNIA,APPROVING CONDITIONAL USE
PERMIT DRC2006-00641,A REQUEST TO CONSTRUCT AND OPERATE
A 16,000 SQUARE FOOT SYNAGOGUE AND PRESCHOOL ON 1.67 NET
ACRE OF LAND IN THE LOW(L) RESIDENTIAL DISTRICT, LOCATED ON
THE SOUTH SIDE OF 19TH STREET AND WEST OF BERYL STREET;
AND MAKING FINDINGS IN SUPPORT THEREOF—APN: 0202-461-61.
A. Recitals.
1. WLC Architects, Inc., for Chabad of the Inland Empire, filed an application for the
issuance of Conditional Use Permit DRC2006-00641 as described in the title of this Resolution.
Hereinafter in this Resolution, the subject Conditional Use Permit request is referred to as "the
application.'
2. On the 27th day of February 2008, the Planning Commission of the City of Rancho
Cucamonga conducted a duly noticed public hearing on the application and concluded said hearing
on that date.
3. All legal prerequisites prior to the adoption of this Resolution have occurred.
B. Resolution.
NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning
Commission of the City of Rancho Cucamonga as follows:
1. This Commission hereby specifically finds that all of the facts set forth in the Recitals,
Part A, of this Resolution are true and correct.
2. Based upon the substantial evidence presented to this Commission during the
above-referenced public hearing on February 27, 2008, including written and oral staff reports,
together with public testimony, this Commission hereby specifically finds as follows:
a. The application applies to the undeveloped property located on the south side of
19th Street and west of Beryl Street. The vacant 1.67-acre site is approximately 200 feet wide,
320 feet deep and has an approximate 200-foot street frontage along 19th Street; and
b. The property is bordered by an existing residential development on the west and
south and by a proposed single-family subdivision to the east(DRC2006-00892 and SUBTT17769).
There are existing multi-family dwellings to the north across 19th Street; and
C. The site is of the appropriate size to accommodate the proposed improvements,
including the provision of required on-site parking and internal vehicular circulation; and
d. Churches and preschools are allowed in Low(L) Residential District subject to the
approval of a Conditional Use Permit; and
e. The synagogue will experience heaviest use on Friday evenings, Saturday, and
Sunday mornings. Throughout the year there will be a number of special events including religious
holidays, weddings, and Bar/Bat Mitzvahs; and
PLANNING COMMISSION RESOLUTION NO. 08-10
DRC2006-00641 —WLC ARCHITECTS INC.
February 27, 2008
Page 2
f. The proposed project complies with City Development Code requirements,
including setbacks, building height, and the provision for on-site parking; and
g. On October 4, 2007, the applicant conducted a neighborhood meeting to solicit
public comments. Nine members from the public attended and were generally accepting of the
proposed project:
3. Based upon the substantial evidence presented to this Commission during the
above-referenced public hearing and upon the specific findings of facts set forth in Paragraphs 1
and 2 above, this Commission hereby finds and concludes as follows:
a. The proposed use is in accord with the General Plan, the objectives of the
Development Code, and the purposes of the district in which the site is located. The proposed
synagogue and preschool are consistent with the goals and objectives of the General Plan, which
encourages land uses to be distributed to meet local needs and be properly integrated into
surrounding context. The site is adequate in size to accommodate the use and the required parking.
Moreover, the proposed project is consistent with the City's design guidelines and complies with the
applicable development criteria contained in the Development Code.
b. The proposed synagogue use, together with the conditions applicable thereto,will
not be detrimental to the public health, safety, or welfare or materially injurious to properties or
improvements in the vicinity. The area surrounding the synagogue site is developed with urban
uses and the proposed improvements will not pose adverse impacts to the adjacent residential
developments. Furthermore, the project site is not located within any habitat conservation or natural
community plan area;therefore, development will not adversely affect rare or endangered species of
plants or animals.
C. The proposed synagogue use complies with applicable provisions of the
Development Code. The proposed improvements will comply with City requirements such as
setbacks, building height, and provision of on-site parking. Additionally,the site has direct access to
fully developed public streets of the appropriate size and configuration to accommodate the use.
4. The Planning Department staff has determined that the project is categorically exempt
from the requirements of the California Environmental Quality Act (CEQA) and the City's CEQA
Guidelines. The project qualifies as a Class 32 exemption under State CEQA Guidelines
Section 15332, which covers in-fill developments which meet the following criteria: 1) they are
consistent with General Plan; 2) they are of less than 5 acres; 3) they have no value as habitat for
endangered, rare, or threatened species; 4) will not have significant effect on the environment
(traffic, noise, air quality, or water quality); and, 5) the site is adequately served by all required
utilities and public services. Having determined that the project meets all the above limitations, staff
finds that there is no substantial evidence that the project may have a significant effect on the
environment. The Planning Commission has reviewed the Planning Department's determination of
exemption, and based on its own independent judgment, concurs in the staffs determination of
exemption.
5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above,
this Commission hereby approves the application subject to each and every condition set forth
below and in the Standard Conditions, attached hereto and incorporated herein by this reference.
PLANNING COMMISSION RESOLUTION NO. 08-10
DRC2006-00641 —WLC ARCHITECTS INC.
February 27, 2008
Page 3
Planning Department
1) This approval is for the development and operation of a synagogue
and preschool use and associated religious instruction, administrative
meetings, etc. Any intensification of the use beyond what is specifically
approved by this Conditional Use Permit shall require review and
approval by the Planning Commission.
2) Approval is also for the removal of 7 trees of various species as
outlined in the Arborist Report prepared by Cy Carlberg and dated
February 4, 2007 (DRC2007-00555).
3) Tree protection fencing shall be installed around one off-site tree that is
directly adjacent to the east property line (Tree A as outlined in the
Arborist Report).
4) The hours of operation for the preschool shall be limited to Monday
through Friday from 6:00 a.m. to 6:00 p.m. Outdoor activity shall not
occur prior to 8:00 a.m. A faculty member or volunteer shall direct
traffic flow through the site and monitor the drop-off and pick-up of
students. All students shall be dropped off on-site and not on the
public street.
5) The Landscape Plan shall include dense fast growing bushes along
the west property line and directly adjacent to the outdoor activity area.
6) The applicant shall make a good-faith-offer to replace the existing
property line walls along the west property line with a single new
combination retaining/free standing wall. The City has a policy against
placing new walls directly adjacent to existing walls.
7) Plans submitted for plan check shall conform to the plans approved by
the Design Review Committee on January 15, 2008,and final Planning
Commission project approval on February 27, 2008.
8) No changes to the approved Site Plan and exterior design of the
synagogue building, including exterior materials, shall be permitted
without prior City review and approval.
9) No outdoor amplified sound system shall be installed and/or utilized on
the subject property, except for short term outdoor events conducted
with proper City approval and permits.
10) On-site parking is based on the maximum available parking of
64 spaces. Parking was calculated at 1 parking space for every 4 fixed
seats. Maximum occupancy of the church and multipurpose room is
256 persons. Maximum occupancy of the entire building shall be
subject to occupancy limits as specified by the Fire Department, but
may not exceed 256 persons.
PLANNING COMMISSION RESOLUTION NO. 08-10
DRC2006-00641 —WLC ARCHITECTS INC.
February 27, 2008
Page 4
11) The applicant shall construct decorative block walls along the east,
west, and south property lines. All walls constructed on site shall be
finished in a decorative manner to complement or match the finish of
the main building on the site.
12) Freestanding parking lot lights shall be limited to a maximum overall
height of 15 feet (including concrete bases) as measured from
adjacent finished grade. The tight fixtures shall be fully flat lens cut-off
"shoebox"with no drop down lenses.
13) The rooftop HVAC equipment shall be completely screened by the roof
parapets.
14) Approval of this request shall not waive compliance with any sections
of the Development Code, State Fire Marshal's regulations, Uniform
Building Code, or any other City Ordinances.
15) The synagogue shall operate in conformance with the performance
standards as defined in the Development Code including, but not
limited to, noise levels. If the operation of the facility causes adverse
effects upon adjacent businesses or operations, the Conditional Use
Permit shall be brought before the Planning Director for consideration
and possible revocation of the Conditional Use Permit.
16) Any signs for the synagogue and preschool shall be designed in
conformance with the City of Rancho Cucamonga Sign Ordinance and
shall require Planning Director review and approval prior to installation.
Enqineerinq Department
1) Prior to the issuance of building permits, the applicant shall submit the
required "Recorded Drainage Easement."
2) Prior to the issuance of building permits, the applicant shall pay
development fees at the rates adopted by City Council, which are
currently estimated as:
a) Drainage Fee: $16,770 per net acre (subject to periodic
changes)
3) Protect existing curb and gutter, sidewalk, street lights, traffic signs,
striping, R26 signs, traffic signal equipment or replace / repair as
required.
4) Monument signs must be placed on private property.
5) An in-lieu fee as contribution to the future undergrounding of the
existing overhead utilities (telecommunications and electrical, except
for the 66 kV electrical) on the opposite side of 19th Street shall be
paid to the City prior to the issuance of building permits. The fee shall
PLANNING COMMISSION RESOLUTION NO. 08-10
DRC2006-00641 —WLC ARCHITECTS INC.
February 27, 2008
Page 5
be one-half the City adopted unit amount times the length of the project
frontage.
Building Department (Grading)
1) All plan sheets shall be signed and sealed by the engineer of record
per Section 6735 of the California Business and Professions Code.
2) Along the west property line an existing retaining wall and fence is
proposed to be removed. Prior to issuance of a grading permit, the
applicant shall obtain letters of permission from the affected property
owners granting permission for the wall/fence removal and
replacement. The letters shall include a site specific exhibit showing
the affected property in relation to the proposed development. In the
event letters of permission can not be obtained, the project applicant
shall submit a revised fencing plan to the Planning Department for
review and approval.
3) Along the east property line, grading is proposed off-site. Prior to the
issuance of a grading permit, the project applicant is conditioned to
provide a letter or easement from the adjacent easterly property owner
granting permission to construct permanent slopes. In the event an
easement or letter(s) of permission can not be obtained, the project
applicant shall submit a revised fencing plan to the Planning
Department for review and approval, showing the construction of a
retaining wall to existing grade with a garden wall on top of the
retaining wall.
4) At the southwest corner of the proposed project site, an emergency
drainage overflow device shall be provided.
5) The project applicant shall construct the proposed off-site storm drain
connecting to the existing City of Rancho Cucamonga maintained
storm drain system in Beryl Street. Prior to the issuance of a grading
permit the applicant shall provide the Building Official a copy of the
storm drain plans deemed 90 percent complete by the Engineering
Department.
6) The off-site storm drain shall be maintained as a private storm drain
system until such time the Engineering Department accepts portions of
the system for public maintenance.
7) Prior to the issuance of a grading permit, the project applicant shall
obtain storm drain easements for both underground storm drainage
piping and emergency overland flows prior to the issuance of a grading
permit.
8) Prior to issuance of a grading permit, the applicant shall obtain a
demolition permit for any structures required to be removed to
construct the off-site storm drain system.
PLANNING COMMISSION RESOLUTION NO. 08-10
DRC2006-00641 —WLC ARCHITECTS INC.
February 27, 2008
Page 6
9) Exterior accessible route of travel signs shall be shown on the precise
grading plan. These signs shall conform to the latest adopted edition
of the California Building Code.
10) All trees and landscaping shall be planted so as to not conflict with the
project storm drain system.
6. The Secretary to this Commission shall certify to the adoption of this Resolution.
APPROVED AND ADOPTED THIS 27TH DAY OF FEBRUARY 2008.
PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA
BY: i
Pam art/ hairman
ATTEST:
Jamff R. Troyer, Secretary
I, James R. Troyer, Secretary of the Planning Commission of the City of Rancho Cucamonga, do
hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted
by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning
Commission held on the 27th day of February 2008, by the following vote-to-wit:
AYES: COMMISSIONERS: FLETCHER, MUNOZ, STEWART, WIMBERLY
NOES: COMMISSIONERS: NONE
ABSENT: COMMISSIONERS: HOWDYSHELL
COMMUNITY DEVELOPMENT
DEPARTMENT
STANDARD CONDITIONS
PROJECT#: DRC2006-00641 AND DRC2007-00553
SUBJECT: CONDITIONAL USE PERMIT AND VARIANCE
APPLICANT: WLC ARCHITECTS
LOCATION: APN: 0202-461-61
ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT.
APPLICANT SHALL CONTACT THE PLANNING DEPARTMENT, (909) 477-2750, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
A. General Requirements Completion Date
1. The applicant shall agree to defend at his sole expense any action brought against the City, its
agents, officers,or employees, because of the issuance of such approval,or in the alternative,to
relinquish such approval. The applicant shall reimburse the City, its agents, officers, or
employees, for any Court costs and attorney's fees which the City, its agents, officers, or
employees may be required by a court to pay as a result of such action. The City may, at its sole
discretion, participate at its own expense in the defense of any such action but such participation
shall not relieve applicant of his obligations under this condition.
2. Copies of the signed Planning Commission Resolution of Approval Nos. 08-10 and 08-11,
Standard Conditions, and all environmental mitigations shall be included on the plans(full size).
The sheet(s)are for information only to all parties involved in the construction/grading activities
and are not required to be wet sealed/stamped by a licensed Engineer/Architect.
3. The applicant shall be required to pay any applicable Fish and Game fees as shown below. The
project planner will confirm which fees apply to this project. All checks are to be made payable to
the Clerk of the Board Supervisors and submitted to the Planning Commission Secretary prior to
the Planning Commission or Planning Director hearing:
a) Notice of Exemption - $50 X
b) Notice of Determination - $50
c) Mitigated Negative Declaration -$ 1,926.75
d) Environmental Impact Report- $2,656.75
SC-1-05 1
(:\PLANNING\FINAL\PLNGC0MM\2008 Res&Stf rep\DRC2006-00641SWCond 2-27.doc
Project No.DRC2006-00641 AND DRC2007-00553
Completion Date
B. Time Limits
1. Conditional Use Permit, Variance, and Development/Design Review approval shall expire if
building permits are not issued or approved use has not commenced within 5 years from the date
of approval. No extensions are allowed.
C. Site Development
1. The site shall be developed and maintained in accordance with the approved plans which include
site plans,architectural elevations,exterior materials and colors,landscaping,sign program,and
grading on file in the Planning Department, the conditions contained herein, and the
Development Code regulations.
2. Prior to any use of the project site or business activity being commenced thereon,all Conditions
of Approval shall be completed to the satisfaction of the Planning Director.
3. Occupancy of the facilities shall not commence until such time as all Uniform Building Code and
State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be
submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety
Department to show compliance. The buildings shall be inspected for compliance prior to
occupancy.
4. Revised site plans and building elevations incorporating all Conditions of Approval shall be
submitted for Planning Director review and approval prior to the issuance of building permits.
5. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for
consistency prior to issuance of any permits (such as grading, tree removal, encroachment,
building, etc.) or prior to final map approval in the case of a custom lot subdivision, or approved
use has commenced, whichever comes first.
6. Approval of this request shall not waive compliance with all sections of the Development Code,all
other applicable City Ordinances, and applicable Community or Specific Plans in effect at the
time of building permit issuance.
7. A detailed on-site lighting plan, including a photometric diagram,shall be reviewed and approved
by the Planning Director and Police Department (477-2800) prior to the issuance of building
permits. Such plan shall indicate style, illumination, location, height,and method of shielding so
as not to adversely affect adjacent properties.
8. If no centralized trash receptacles are provided,all trash pick-up shall be for individual units with
all receptacles shielded from public view.
9. Trash receptacle(s)are required and shall meet City standards. The final design, locations, and
the number of trash receptacles shall be subject to Planning Director review and approval prior to
the issuance of building permits.
10. All ground-mounted utility appurtenances such as transformers, AC condensers, etc., shall be
located out of public view and adequately screened through the use of a combination of concrete
or masonry walls, berming, and/or landscaping to the satisfaction of the Planning Director. For
single-family residential developments, transformers shall be placed in underground vaults.
11. All building numbers shall be identified in a clear and concise manner, including proper
illumination.
12. All parkways, open areas, and landscaping shall be permanently maintained by the property
owner, homeowners'association,or other means acceptable to the City. Proof of this landscape
maintenance shall be submitted for Planning Director and City Engineer review and approved
prior to the issuance of building permits.
2
1:\PLANNING\FINAL\PLNGC0MM\2008 Res&Stf rep\DRC2006-00641StdCond 2-27.doc
Project No.DRC2006-00641 AND DRC2007-00553
Completion Date
13. The developer shall submit a construction access plan and schedule for the development of all
lots for Planning Director and City Engineer approval; including, but not limited to, public notice
requirements,special street posting, phone listing for community concerns,hours of construction
activity, dust control measures, and security fencing.
14. Six-foot decorative block walls shall be constructed along the project perimeter. If a double wall
condition would result, the developer shall make a good faith effort to work with the adjoining
property owners to provide a single wall. Developer shall notify, by mail, all contiguous property
owner at least 30 days prior to the removal of any existing walls/ fences along the project's
perimeter.
D. Building Design
1. All roof appurtenances, including air conditioners and other roof mounted equipment and/or
projections, shall be shielded from view and the sound buffered from adjacent properties and
streets as required by the Planning Department. Such screening shall be architecturally
integrated with the building design and constructed to the satisfaction of the Planning Director.
Details shall be included in building plans.
E. Parking and Vehicular Access (indicate details on building plans)
1. All parking spaces shall be 9 feet wide by 18 feet long. When a side of any parking space abuts
a building, wall, support column, or other obstruction, the space shall be a minimum of 11 feet
wide.
2. All parking lot landscape islands shall have a minimum outside dimension of 6 feet and shall
contain a 12-inch walk adjacent to the parking stall (including curb).
3. Textured pedestrian pathways and textured pavement across circulation aisles shall be provided
throughout the development to connect dwellings/units/buildings with open spaces/plazas/
recreational uses.
4. All parking spaces shall be double striped per City standards and all driveway aisles,entrances,
and exits shall be striped per City standards.
5. Plans for any security gates shall be submitted for the Planning Director, City Engineer, and
Rancho Cucamonga Fire Protection District review and approval prior to issuance of building
permits. For residential development, private gated entrances shall provide adequate turn-
around space in front of the gate and a separate visitor lane with call box to avoid cars stacking
into the public right-of-way.
F. Landscaping
1. A detailed landscape and irrigation plan, including slope planting and model home landscaping in
the case of residential development, shall be prepared by a licensed landscape architect and
submitted for Planning Director review and approval prior to the issuance of building permits or
prior final map approval in the case of a custom lot subdivision.
2. Within parking lots, trees shall be planted at a rate of one 15-gallon tree for every three parking
stalls.
3. Trees shall be planted in areas of public view adjacent to and along structures at a rate of one
tree per 30 linear feet of building.
3
I:\PLANNING\FINAL\PLNGCOMM\2008 Res&Stf rep\DRC2006-00641StdCond 2-27.doc
Project No. DRC2006-00641 AND DRC2007-00553
completion Date
4. All private slopes of 5 feet or more in vertical height and of 5:1 or greater slope, but less than 2:1
slope, shall be,at minimum, irrigated and landscaped with appropriate ground cover for erosion
control. Slope planting required by this section shall include a permanent irrigation system to be
installed by the developer prior to occupancy.
5. Landscaping and irrigation systems required to be installed within the public right-of-way on the
perimeter of this project area shall be continuously maintained by the developer.
6. All walls shall be provided with decorative treatment. If located in public maintenance areas,the
design shall be coordinated with the Engineering Department.
7. Tree maintenance criteria shall be developed and submitted for Planning Director review and
approval prior to issuance of building permits.These criteria shall encourage the natural growth
characteristics of the selected tree species.
8. Landscaping and irrigation shall be designed to conserve water through the principles of
Xeriscape as defined in Chapter 19.16 of the Rancho Cucamonga Municipal Code.
G. Signs
1. The signs indicated on the submitted plans are conceptual only and not a part of this approval.
Any signs proposed for this development shall comply with the Sign Ordinance and shall require
separate application and approval by the Planning Department prior to installation of any signs.
APPLICANT SHALL CONTACT THE BUILDING AND SAFETY DEPARTMENT,(909)477-2710,
FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS:
NOTE: ANY REVISIONS MAY VOID THESE REQUIREMENTS AND NECESSITATE ADDITIONAL REVIEW(S)
H. General Requirements
1. Submit five complete sets of plans including the following:
a. Site/Plot Plan;
b. Foundation Plan;
C. Floor Plan;
d. Ceiling and Roof Framing Plan;
e. Electrical Plans (2 sets, detached) including the size of the main switch, number and size
of service entrance conductors, panel schedules, and single line diagrams;
f. Plumbing and Sewer Plans, including isometrics, underground diagrams,water and waste
diagram, sewer or septic system location, fixture units, gas piping, and heating and air
conditioning; and
g. Planning Department Project Number(i.e., DRC2006-00641 and DRC2007-00553)clearly
identified on the outside of all plans.
2. Submit two sets of structural calculations, energy conservation calculations, and a soils report.
Architect's/Engineer's stamp and "wet" signature are required prior to plan check submittal.
3. Contractors must show proof of State and City licenses and Workers'Compensation coverage to
the City prior to permit issuance.
4. Separate permits are required for fencing and/or walls.
4
1:\PLANNING\FINAL\PLNGC0MM\2008 Res&Stf rep\DRC2006-00641StdCond 2-27.doc
Project No. DRC2006-00641 AND DRC2007-00553
Completion Date
5. Business shall not open for operation prior to posting the Certificate of Occupancy issued by the
Building and Safety Department.
1. Site Development
1. Plans shall be submitted for plan check and approved prior to construction. All plans shall be
marked with the project file number(i.e., DRC2006-00641 and DRC2007-00553). The applicant
shall comply with the latest adopted California Codes,and all other applicable codes,ordinances,
and regulations in effect at the time of permit application. Contact the Building and Safety
Department for availability of the Code Adoption Ordinance and applicable handouts.
2. Prior to issuance of building permits for a new commercial or industrial development project or
major addition,the applicant shall pay development fees at the established rate. Such fees may
include but are not limited to: City Beautification Fee, Park Fee, Drainage Fee, Transportation
Development Fee, Permit and Plan Check Fees,Construction and Demolition Diversion Program
deposit and fees and School Fees. Applicant shall provide a copy of the school fees receipt to
the Building and Safety Department prior to permits issuance.
3. Street addresses shall be provided by the Building and Safety Official after tract/parcel map
recordation and prior to issuance of building permits.
4. Construction activity shall not occur between the hours of 8:00 p.m. and 6:30 a.m. Monday
through Saturday, with no construction on Sunday or holidays.
5. Construct trash enclosure(s) per City Standard (available at the Planning Department's public
counter).
J. New Structures
1. Provide compliance with the California Building Code (CBC) for property line clearances
considering use, area, and fire-resistiveness.
2. Provide compliance with the California Building Code for required occupancy separations.
3. Provide draft stops in attic areas, not to exceed 3,000 square feet, in accordance with CBC
Section 1505.
4. Exterior walls shall be constructed of the required fire rating in accordance with CBC Table 5-A
5. Openings in exterior walls shall be protected in accordance with CBC Table 5-A.
6. Upon tenant improvement plan check submittal, additional requirements may be needed.
K. Grading
1. Grading of the subject property shall be in accordance with California Building Code,City Grading
Standards, and accepted grading practices. The final grading plan shall be in substantial
conformance with the approved grading plan.
2. A soils report shall be prepared by a qualified engineer licensed by the State of California to
perform such work.
3. A geological report shall be prepared by a qualified engineer or geologist and submitted at the
time of application for grading plan check.
4. The final grading plan, appropriate certifications and compaction reports shall be completed,
submitted, and approved by the Building and Safety Official prior to the issuance of building
permits.
5
11PLANNINGTINALTLNGCOW2008 Res&Stf rep\DRC2006-00641StdCond 2-27.doc
Project No. DRC2006-00641 AND DRC2007-00553
Completion Date
APPLICANT SHALL CONTACT THE ENGINEERING DEPARTMENT, (909) 477-2740, FOR
COMPLIANCE WITH THE FOLLOWING CONDITIONS:
L. Street Improvements
1. All public improvements(interior streets,drainage facilities,community trails,paseos,landscaped
areas, etc.) shown on the plans and/or tentative map shall be constructed to City Standards.
Interior street improvements shall include, but are not limited to,curb and gutter,AC pavement,
drive approaches, sidewalks, street lights, and street trees.
2. Pursuant to City Council Resolution No.88-557,no person shall make connections from a source
of energy,fuel or power to any building service equipment which is regulated by technical codes
and for which a permit is required unless, in addition to any and all other codes, regulations and
ordinances, all improvements required by these conditions of development approval have been
completed and accepted by the City Council, except:that in developments containing more than
one building or unit, the development may have energy connections made to a percentage of
those buildings, or units proportionate to the completion of improvements as required by
conditions of approval of development. In no case shall more than 95 percent of the buildings or
units be connected to energy prior to completion and acceptance of all improvements required by
these conditions of approval of development.
3. Construct the following perimeter street improvements including, but not limited to:
Curb& A.C. Side- Drive Street Street Comm Median I Bike
Street Name Gutter Pvmt walk Appr. Lights Trees Trail Islantl Trail Other
19th Street X X
4. Improvement Plans and Construction:
a. Street improvement plans, including street trees,street lights,and intersection safety lights
on future signal poles, and traffic signal plans shall be prepared by a registered Civil
Engineer and shall be submitted to and approved by the City Engineer. Security shall be
posted and an agreement executed to the satisfaction of the City Engineer and the City
Attorney guaranteeing completion of the public and/or private street improvements,prior to
final map approval or the issuance of building permits, whichever occurs first.
b. Prior to any work being performed in public right-of-way, fees shall be paid and a
construction permit shall be obtained from the City Engineer's Office in addition to any
other permits required.
5. Provide a minimum of 3-inch conduit for future fiber optic use on all streets with connection
through the parkway to each lot or parcel (fiber-to-the curb, FITC). The size, placement, and
location of the conduit shall be shown on the Street Improvement Plans and subject to City
Engineer review and approval prior to issuance of building permits or final map approval,
whichever comes first.
6
I:\PLANNING\FINAL\PLNGCOMM\2008 Res&Stf rep\DRC2006-00641StdCond 2-27.doc
Project No. DR02006-00641 AND DRC2007-00553
Completion Date
8. Install street trees per City street tree design guidelines and standards as follows. The completed
legend (box below) and construction notes shall appear on the title page of the street
improvement plans. Street improvement plans shall include a line item within the construction
legend stating: "Street trees shall be installed per the notes and legend on sheet_(typically
sheet 1)." Where public landscape plans are required, tree installation in those areas shall be
per the public landscape improvement plans.
The City Engineer reserves the right to adjust tree species based upon field conditions and other
variables. For additional information, contact the Project Engineer.
Min.
Grow
Street Name Botanical Name Common Name Space Spacing Size city.
19th Street Crape Myrtle 15 Gal.
Construction Notes for Street Trees:
1) All street trees are to be planted in accordance with City standard plans.
2) Prior to the commencement of any planting, an agronomic soils report shall be furnished to
the City inspector. Any unusual toxicities or nutrient deficiencies may require backfill soil
amendments, as determined by the City inspector.
3) All street trees are subject to inspection and acceptance by the Engineering Department.
4) Street trees are to be planted per public improvement plans only.
M. Drainage and Flood Control
1. Public storm drain easements shall be graded to convey overflows in the event of a blockage in a
sump catch basin on the public street, and provisions made to pass through walls.
N. Utilities
1. Provide separate utility services to each parcel including sanitary sewerage system, water, gas,
electric power, telephone, and cable TV (all underground) in accordance with the Utility
Standards. Easements shall be provided as required.
2. The developer shall be responsible for the relocation of existing utilities as necessary.
3. Water and sewer plans shall be designed and constructed to meet the requirements of the
Cucamonga Valley Water District(CVW D), Rancho Cucamonga Fire Protection District,and the
Environmental Health Department of the County of San Bernardino. A letter of compliance from
the CVW D is required prior to final map approval or issuance of permits,whichever occurs first.
Such letter must have been issued by the water district within 90 days prior to final map approval
in the case of subdivision or prior to the issuance of permits in the case of all other residential
projects.
O. General Requirements and Approvals
1- Prior to the issuance of building permits,a Diversion Deposit and related administrative fees shall
be paid for the Construction and Demolition Diversion Program. The deposit is fully refundable if
at least 50% of all wastes generated during construction and demolition are diverted from
landfills,and appropriate documentation is provided to the City. Form CD-1 shall be submitted to
the Engineering Department when the first building permit application is submitted to Building and
Safety. Form CD-2 shall be submitted to the Engineering Department within 60 days following
the completion of the construction and/or demolition project-
7
I:\PLANNING\FINAL\PLNGCOMM\2008 Res 8 SO rep\DRC2006-00641StdCond 2-27.doc
Project No. DRC2006-00641 AND DRC2007-00553
Completion Date
2. Prior to approval of the final map, or prior to improvement agreement approval if no map is
involved, all Tract Maps, Parcel Maps and public improvement plans shall be submitted to the
Engineering Division on a compact disc (CD) in Auto CAD (computer aided design) format. If
public improvement plans are completed after map approval, the CD shall be submitted prior to
issuance of a construction permit for frontage improvements or a building permit, whichever
occurs first.
APPLICANT SHALL CONTACT THE FIRE SAFETY DEPARTMENT, FIRE PROTECTION
PLANNING SERVICES AT, (909) 477-2770, FOR COMPLIANCE WITH THE FOLLOWING
CONDITIONS:
SEE ATTACHED
8
LTLANNINGTINAL\PLNGCOMM\2008 Res& Stf rep\DRC2006-00641StdCond 2-27.doc
Rancho Cucamonga Fire Protection District
Fire Construction Services
STANDARD CONDITIONS
June 19, 2006
Chabad of the Inland Empire
19th E/O Beryl
New Church/School
DRC2006-00641
THE FOLLOWING STANDARD CONDITIONS APPLY TO THIS PROJECT
The RCFPD Procedures & Standards which are referenced in this document can be access on
the web at htto://www.ci.rancho-cucamoncia.ca.us/fire/index.htm under the Fire Safety Division & Fire
Construction Services section. Search by article; the preceding number of the standard refers
to the article. Chose the appropriate article number then a drop down menu will appear, select
the corresponding standard.
FSC-1 Public and Private Water Supply
1. Design guidelines for Fire Hydrants: The following provides design guidelines for the
spacing and location of fire hydrants:
a. The maximum distance between fire hydrants in commercial/industrial projects is
300-feet. No portion of the exterior wall shall be located more than 150-feet from an
approved fire hydrant. For cul-de-sacs, the distance shall not exceed 100-feet.
b. The preferred locations for fire hydrants are:
i. At the entrance(s) to a commercial, industrial or residential project from the public
roadways.
ii. At intersections.
iii. On the right side of the street, whenever practical and possible.
iv. As required by the Fire Safety Division to meet operational needs of the Fire
District.
v. A minimum of forty-feet (40') from any building.
c. If any portion of a facility or building is located more than 150-feet from a public fire
hydrant measured on an approved route around the exterior of the facility or building,
additional private or public fire hydrants and mains capable of supplying the required
fire flow shall be provided.
d. Provide one fire hydrant for each 1000 gpm of required fire flow or fraction thereof.
FSC-2 Fire Flow
1. The required minimum fire flow for this project, when automatic fire sprinklers are installed
will be determined in gallons per minute at a minimum residual pressure of 20-pounds per
square inch. This flow reflects a 50-percent reduction for the installation of an approved
automatic fire sprinkler system in accordance with NFPA 13 with central station monitoring.
This requirement is made in accordance with the California Fire Code Appendix III-A, as
adopted by the Fire District Ordinances.
2. Public fire hydrants located within a 500-foot radius of the proposed project may be used to
provide the required fire flow subject to Fire District review and approval. Private fire
hydrants on adjacent property shall not be used to provide required fire flow.
3. Fire protection water plans are required for all projects that must extend the existing water
supply to or onto the site. Building permits will not be issued until fire protection water
plans are approved.
4. On all site plans to be submitted for review, show all fire hydrants located within 600-feet of
the proposed project site.
FSC-3 Prerequisite for submittal of Overhead Automatic Fire Sprinkler Systems
1. Prior to submitting plans for an overhead automatic fire sprinkler system, the applicant shall
submit plans, specifications and calculations for the fire sprinkler system underground
supply piping. Approval of the underground supply piping system must be obtained prior to
submitting the overhead fire sprinkler system plans.
FSC-4 Requirements for Automatic Fire Sprinkler Systems
Rancho Cucamonga Fire District Ordinance 15, the 2001 California Fire Code and/or any other
applicable standards require an approved automatic fire sprinkler system to be installed in:
1. Commercial or industrial structures greater than 7,500 square feet.
2. Group "A" Occupancies.
3. "E" Occupancies with an occupant load of 50 or more persons.
4. All structures that do not meet Fire District access requirements (see Fire Access).
5. When required fire flow cannot be provided due to inadequate volume or pressure.
6. When the building access does not meet the requirements of the 2001 California Building
Code and the RCFPD Fire Department Access - Fire Lane Standard #9-7
7. When any applicable code or standard requires the structure to be sprinklered.
FSC-5 Fire Alarm System
1. The California Building Code, the RCFPD Fire Alarm Standard #10-6 and/or the California
Fire Code require a listed fire sprinkler monitoring Central Station Fire Alarm system. Plan
check approval and a building permit are required Prior to the installation of the fire alarm
system. Plans and specifications shall be submitted to Fire Construction Services in
accordance with RCFPD Fire Alarm Standard #10-6.
1)
FSC-6 Fire District Site Access
Fire District access roadways include public roads, streets and highways, as well as private
roads, streets drive aisles and/or designated fire lanes. Please reference the RCFPD Fire
Department Access Roadways Std #9-7.
1. Location of Access: All portions of the structures 1s` story exterior wall shall be located
within 150-feet of Fire District vehicle access, measure on an approved route around the
exterior of the building. Landscaped areas, unpaved changes in elevation, gates and
fences are deemed obstructions.
2. Specifications for private Fire District access roadways per the RCFPD Standards
are:
a. The minimum unobstructed width is 26-feet.
b. The maximum inside turn radius shall be 24-feet.
c. The minimum outside turn radius shall be 50-feet.
d. The minimum radius for cul-de-sacs is 45-feet.
e. The minimum vertical clearance is 14-feet, 6-inches.
f. At any private entry median, the minimum width of traffic lanes shall be 20-feet on each
side.
g. The angle of departure and approach shall not exceed 9-degrees or 20 percent.
h. The maximum grade of the driving surface shall not exceed 12%.
i. Support a minimum load of 70,000 pounds gross vehicle weight (GVW).
j. Trees and shrubs planted adjacent to the fire lane shall be kept trimmed to a minimum
of 14-feet, 6-inches from the ground up. Vegetation shall not be allowed to obstruct
Fire Department apparatus.
3. Access Doorways: Approved doorways, accessible without the use of a ladder, shall be
provided as follows:
a. In buildings without high-piled storage, access shall be provided in accordance with the
2001 California Building Code, Fire and/or any other applicable standards.
b. In buildings with high-piled storage access doors shall be provided in each 100 lineal
feet or major fraction thereof, of the exterior wall that faces the required access
roadways. When railways are installed provisions shall be made to maintain Fire
District access to all required openings.
4. Access Walkways: Hardscaped access walkways shall be provided from the fire
apparatus access road to all required building exterior openings. -
3
5. Commercial/Industrial Gates: Any gate installed across a Fire Department access road
shall be in accordance with Fire District Standard #9-2. The following design requirements
apply:
a. Prior to the fabrication and installation of the gates, plans are required to be submitted
to Fire Construction Services (FCS) for approval. Upon the completion of the
installation and before placing the gates in service, inspection and final acceptance
must be requested from FCS.
b. Gates must slide open horizontally or swing inward.
c. Gates may be motorized or manual.
d. When fully open, the minimum clearance dimension of drive access shall be 20 feet.
c. Manual gates must be equipped with a RCFPD lock available at the Fire Safety Office
for $20.00.
f. Motorized gates must open at the rate of one-foot per second.
g. The motorized gate actuation mechanism must be equipped with a manual override
device and a fail-safe or battery backup feature to open the gate or release the locking
Mechanism in case of power failure or mechanical malfunction.
h. Motorized gates shall be equipped with a Knox override key switch. The switch must
be installed outside the gate in a visible and unobstructed location.
i. For motorized gates, a traffic loop device must be installed to allow exiting from the
complex.
j. If traffic pre-emption devices (TPD) are to be installed, the device, location and
operation must be approved by the Fire Chief prior to installation. Bi-directional or
multiple sensors may be required due to complexity of the various entry configurations.
7. Fire Lane Identification: Red curbing and/or signage shall identify the fire lanes. A site
plan illustrating the proposed delineation that meets the minimum Fire District standards
shall be included in the architectural plans submitted to B&S for approval.
8. Approved Fire Department Access: Any approved mitigation measures must be clearly
noted on the site plan. A copy of the approved Alternative Method application, if applicable,
must be reproduced on the architectural plans submitted to B&S for plan review.
6. Roof Access: There shall be a means of fire department access from the exterior walls of
the buildings on to the roofs of all commercial, industrial and multi-family residential
structures with roofs less than 75' above the level of the fire access road.
a. This access must be reachable by either fire department ground ladders or by an aerial
ladder.
b. A minimum of one ladder point with a fixed ladder shall be provided in buildings with
construction features, or high parapets that inhibit roof access.
4
c. The number of ladder points may be required to be increased, depending on the
building size and configuration.
d. Regardless of the parapet height or construction features the approved ladder point
shall be identified in accordance to the roof access standard.
e. Where the entire roof access is restricted by high parapet walls or other obstructions, a
permanently mounted access ladder is required.
f. Multiple access ladders may be required for larger buildings.
g. Ladder construction must be in accordance with the RCFPD Roof Access Standard 9-9
Appendix A and drawings 9-9a and 9-91b.
h. A site plan showing the locations of the roof ladder shall be submitted during plan
check.
i. Ladder points shall face a fire access roadway(s).
FSC-10 Occupancy and Hazard Control Permits
Listed are those Fire Code permits commonly associated with the business operations and/or
building construction. Plan check submittal is required with the permit application for approval
of the permit; field inspection is required prior to permit issuance. General Use Permit shall be
required for any activity or operation not specifically described below, which in the judgment of
the Fire Chief is likely to produce conditions that may be hazardous to life or property.
• Candles and open flames in public assemblies
• Hazardous Materials
• Tents, Canopies and/or Air Supported Structures
• LPG or Gas Fuel Vehicles in Assembly Buildings.
FSC-11 Hazardous Materials — Submittal to the County of San Bernardino
The San Bernardino County Fire Department shall review your Business
Emergency/Contingency Plan for compliance with minimum standards. Contact the San
Bernardino County Fire, Hazardous Materials Division at (909) 387-4631 for forms and
assistance. The County Fire Department is the Cal/EPA Certified Unified Program Agency
(CUPA) for the City of Rancho Cucamonga.
1. If the facility is a NEW business, a Certificate of Occupancy issued by Building & Safety will
not be finalized until the San Bernardino County Fire Department reviews your Business
Emergency/Contingency Plan. California Government Code, Section 65850.2 prohibits the
City from issuing a final Certificate of Occupancy unless the applicant has met or is meeting
specific hazardous materials disclosure requirements. A Risk Management Program
(RMP) may also be required if regulation substances are to be used or stored at the new
facility.
5
2. Any business that operates on rented or leased property which is required to submit a Plan,
is also required to submit a notice to the owner of the property in writing stating that the
business is subject to the Business Emergency/Contingency Plan mandates and has
complied with the provisions. The tenant must provide a copy of the Plan to the property
owner within five (5) working days, if requested by the owner.
FSC-12 Hazardous Materials - Submittal to Fire Construction Services
Plans shall be submitted and approved prior to construction of buildings and/or the installation of
equipment designed to store, use or dispense hazardous materials in accordance with the 2001
California Building, Fire, Mechanical, Plumbing, Electrical Codes, RCFPD Ordinances FD15 and
FD39 and other implemented and/or adopted standards.
FSC-13 Alternate Method Application
Fire Construction Services staff and the Fire Marshal will review all requests for alternate
method, when submitted. The request must be submitted on the Fire District "Application for
Alternate Method" form along with supporting documents and payment of the $92 review fee.
FCS-15 Annexation of the parcel: Annexation of the parcel into the Community Facilities
District #85-1 or#88-1 is required prior to the issuance of grading or building permits.
Chronological Summary of RCFPD Standard
Conditions
PRIOR TO ISSUANCE OF BUILDING PERMITS — Please complete the following prior to
the issuance of any building permits:
1. Private Water Supply (Fire) Systems: The applicant shall submit construction plans,
specifications, flow test data and calculations for the private water main system for review
and approval by the Fire District. Plans and installation shall comply with Fire District
Standards. Approval of the on-site (private) fire underground and water plans is required
prior to any building permit issuance for any structure on the site. Private on-site
combination domestic and fire supply system must be designed in accordance with RCFPD
Standards # 9-4, #10-2 and #10-4. The Building & Safety Division and Fire Construction
Services will perform plan checks and inspections.
All private on-site fire hydrants shall be installed, flushed and operable prior to delivering
any combustible framing materials to the site. Fire construction Services will inspect the
installation, witness hydrant flushing and grant a clearance before lumber is dropped.
2. Public Water Supply (Domestic/Fire) Systems: The applicant shall submit a plan
showing the locations of all new public fire hydrants for the review and approval by the Fire
District and CCWD. On the plan, show all existing fire hydrants within a 600-foot radius of
the project. Please reference the RCFPD Water Plan Submittal Procedure Standard.
All required public fire hydrants shall be installed, flushed and operable prior to delivering
any combustible framing materials to the site. CCWD personnel shall inspect the
installation and witness the hydrant flushing. Fire Construction Services shall inspect the
site after acceptance of the public water system by CCWD. Fire Construction Services
must grant a clearance before lumber is dropped.
6
3. Construction Access: The access roads must be paved in accordance with all the
requirements of the RCFPD Fire Lane Standard #9-7. All temporary utilities over access
roads must be installed at least 14' 6" above the finished surface of the road.
4. Fire Flow: A current fire flow letter from CCWD must be received. The applicant is
responsible for obtaining the fire flow information from CCWD and submitting the letter to
Fire Construction Services.
5. Easements and Reciprocal Agreements: All easements and agreements must be
recorded with the County of San Bernardino.
PRIOR TO THE RELEASE OF TEMPORARY POWER
The building construction must be substantially completed in accordance with Fire Construction
Services' "Temporary Power Release Checklist and Procedures".
PRIOR TO OCCUPANCY OR FINAL INSPECTION — Please complete the following:
1. Hydrant Markers: All fire hydrants shall have a blue reflective pavement marker indicating
the fire hydrant location on the street or driveway in accordance with the City of Rancho
Cucamonga Engineering Standard Plan 134, "Installation of Reflective Hydrant Markers".
On private property, the markers shall be installed at the centerline of the fire access road,
at each hydrant location.
2. Private Fire Hydrants: For the purpose of final acceptance, a licensed sprinkler contractor,
in the presence of Fire Construction Services, shall conduct a test of the most hydraulically
remote on-site fire hydrants. The underground fire line contractor, developer and/or owner
are responsible for hiring the company to perform the test. A final test report shall be
submitted to Fire Construction Services verifying the fire flow available. The fire flow
available must meet or exceed the required fire flow in accordance with the California Fire
Code.
3. Fire Sprinkler System: Prior to the issuance of a Certificate of Occupancy, the fire
sprinkler system(s) shall be tested and accepted by Fire Construction Services.
4. Fire Sprinkler Monitoring: Prior to the issuance of a Certificate of Occupancy, the fire
sprinkler monitoring system must be tested and accepted by Fire Construction Services.
The fire sprinkler monitoring system shall be installed, tested and operational immediately
following the completion of the fire sprinkler system (subject to the release of power).
5. Fire Suppression Systems and/or other special hazard protection systems shall be
inspected, tested and accepted by Fire Construction Services before occupancy is granted
and/or equipment is placed in service.
6. Fire Alarm System: Prior to the issuance of a Certificate of Occupancy, the fire alarm
system shall be installed, inspected, tested and accepted by Fire Construction Services.
7. Access Control Gates: Prior to the issuance of a Certificate of Occupancy, vehicular
gates must be inspected, tested and accepted in accordance with RCFPD Standards #9-1
or #9-2 by Fire Construction Services.
7
8. Fire Access Roadways: Prior to the issuance of any Certificate of Occupancy, the fire
access roadways must be installed in accordance with the approved plans and acceptable
to Fire Construction Services.
The CC&R's, the reciprocal agreement and/or other approved documents shall be
recorded and contain an approved fire access roadway map with provisions that prohibit
parking, specify the method of enforcement and identifies who is responsible for the
required annual inspections and the maintenance of all required fire access roadways.
9. Address: Prior to the issuance of a Certificate of Occupancy, commercial/industrial and
multi-family buildings shall post the address with minimum 8-inch numbers on contrasting
background, visible from the street and electrically illuminated during periods of darkness.
When the building setback exceeds 200 feet from the public street, an additional non-
illuminated 6-inch minimum number address shall be provided at the property entrance.
Larger address numbers will be required on buildings located on wide streets or built with
large setbacks in multi-tenant commercial and industrial buildings. The suite designation
numbers and/or letters shall be provided on the front and back of all suites.
10. Hazardous Materials: Prior to the issuance of a Certificate of Occupancy, the applicant
must demonstrate (in writing from the County) that the facility has met or is meeting the
Risk Management Plan (RMP) or Business Emergency/Contingency Plan with the San
Bernardino County Fire Department, Hazardous Materials/Emergency Response and
Enforcement Division. The applicant must also obtain inspection and acceptance by Fire
Construction Services.
11. Confidential Business Occupancy Information: The applicant shall complete the
Rancho Cucamonga Fire District "Confidential Business Occupancy Information" form. This
form provides contact information for Fire District use in the event of an emergency at the
subject building or property. This form must be presented to the Fire Construction Services
Inspector.
12. Mapping Site Plan: Prior to the issuance of a Certificate of Occupancy, a 8 Y2" x 11" or 11"
x 17" site plan of the site in accordance with RCFPD Standard #13-1 shall be revised by the
applicant to reflect the actual location of all devices and building features as required in the
standard. The site plan must be reviewed and accepted by the Fire Inspector.