HomeMy WebLinkAbout2011/07/05 - Agenda Packet - (2) DESIGN REVIEW COMMITTEE MEETING
TUESDAY JULY 5, 2011 7:00 P.M.
RANCHO CUCAMONGA CIVIC CENTER
RAINS ROOM
10500 CIVIC CENTER DRIVE
RANCHO CUCAMONGA
Committee Members: Lou Munoz Ray Wimberly James Troyer Donald Granger
Alternates: Frances Howdyshell Richard Fletcher Francisco Oaxaca
CONSENT CALENDAR
NO ITEMS SUBMITTED.
PROJECT REVIEW ITEMS
This is the time and place for the Committee to discuss and provide direction to an applicant regarding
their development application. The following items do not legally require any public testimony, although
the Committee may open the meeting for public input.
7:00 p.m.
(Steve/Willie) DESIGN REVIEW DRC2011-00047 - MERITAGE HOMES - The design review of
building elevations and detailed Site Plan for 23 single-family lots on 7.74 acres of
land in the Low Residential District (2-4 dwelling units per acre) of the
Etiwanda North Specific Plan, located on the west side of Day Creek Boulevard,
south of Vintage Drive - APN: 0225-161-65 and 71. Related Files: Tentative Tract
Map SUBTT18032, Tree Removal Permit DRC2006-00871, and
Variance DRC2007-00097. On April 9, 2008, a Mitigated Negative Declaration was
adopted by the Planning Commission for Tentative Tract Map SUBTT18032. The
California Environmental Quality Act provides that no further environmental review or
Negative Declaration is required for subsequent projects or minor revisions to
projects within the scope of a previous Negative Declaration.
7:20 p.m.
(Dominick/Carlo) MINOR DEVELOPMENT REVIEW DRC2011-00155 - JASON LEE -A request to divide
an existing single-tenant building to accommodate three tenants within the
Foothill Boulevard Community Commercial District (Subarea 2), located at
8939 Foothill Boulevard - APN: 0208-192-07. Related files: DRC2011-00468 and
DRC2011-00469. This project is categorically exempt from the requirements of the
California Environmental Quality Act (CEQA) pursuant to State CEQA Guidelines
Section 15301 (Class 1 Exemption - Existing Facilities).
UNIFORM SIGN PROGRAM DRC2011-00469 - JASON LEE -A Uniform Sign Program
for Minor Development Review DRC2011-00155, a proposal to subdivide an existing
single-tenant commercial building into three units within the Foothill Boulevard
Community Commercial District (Subarea 2), located at 8939 Foothill Boulevard -
APN: 0208-192-07. Related files: DRC2011-00155 and DRC201100468.
DRC AGENDA
July 5, 2011
Page 2
PUBLIC COMMENTS
This is the time and place for the general public to address the Committee. State law prohibits the
Committee from addressing any issue not previously included on the Agenda. The Committee may
receive testimony and set the matter for a subsequent meeting. Comments are limited to five minutes
per individual.
ADJOURNMENT
I, Gail Elwood, Office Specialist II for the City of Rancho Cucamonga, hereby certify that a true, accurate
copy of the foregoing agenda was posted on June 22, 2011, at least 72 hours prior to the meeting per
Government Code Section 54954.2 at 10500 Civic Center Drive, Rancho Cucamonga.
•
•
DESIGN REVIEW COMMENTS
7:00 p.m. Steve Fowler July 5, 2011
DESIGN REVIEW DRC2011-00047 - MERITAGE HOMES - The design review of building elevations
and detailed Site Plan for 23 single-family lots on 7.74 acres of land in the Low Residential District
(2-4 dwelling units per acre) of the Etiwanda North Specific Plan, located on the west side of Day Creek
Boulevard, south of Vintage Drive - APN: 0225-161-65 and 71. Related files: Tentative Tract Map
SUBTT18032, Tree Removal Permit DRC2006-00871, and Variance DRC2007-00097. On April 9, 2008,
a Mitigated Negative Declaration was adopted by the Planning Commission for Tentative Tract Map
SUBTT18032. The California Environmental Quality Act provides that no further environmental review or
Negative Declaration is required for subsequent projects or minor revisions to projects within the scope
of a previous Negative Declaration.
Background: On April 9, 2008, the Planning Commission approved Tentative Tract Map 18032 for the
subdivision of 23 lots on 7.74 acres in the Low Residential District (2-4 dwelling units per acre) of the
Etiwanda North Specific Plan, located on the west side of Day Creek Boulevard, south of Vintage Drive.
At the time of the subdivision, no housing product was proposed.
The site falls within the Etiwanda North Specific Plan, just outside the boundaries of the
Rancho Etiwanda planned development, a 1,238 residential unit development approved by the County in
May 1991, and subsequently annexed into the City of Rancho Cucamonga. The streets surrounding the
project site were installed when the Rancho Etiwanda area was mass graded, infrastructure was
installed, and adjacent subdivisions were built. The site is bordered by single-family homes to the north,
west, and across Day Creek Boulevard. To the south is the SR-210 Freeway.
Design Parameters: The applicant is required to develop within substantial compliance with the
Etiwanda North Specific Plan (ENSP) Day Creek Neighborhood, incorporating the architecture and
design details of the Etiwanda area. This project includes 23 homes. Requirements include side-on
garages, recessed garages, and exterior siding. The specific architectural styles shall include enough
materials, elements, and details that reflect the character of the style.
The "Day Creek" neighborhood, which has its own unique architectural design guidelines per the ENSP,
requires that a mix of the following primary architectural styles be used for at least two-thirds of the units:
Bungalow, Ranch, Country, or Victorian. Up to one-third of the units may use these styles:
Santa Barbara Revival, Monterey, or San Juan.
The proposed homes are consistent with the required architectural styles and include Floor Plans that
range from a 2,194 square foot plan to a 3,154 square foot plan. These plans provide a large yard area
to meet the demand of the current housing market with lots ranging from 8,180 square feet to
23,991 square feet. A total of 7 (30 percent) of the proposed house product will be single-story. The
two-story plans have been designed with three Floor Plans, and all of the plans have three architectural
styles. The proposed architectural styles are San Juan, Bungalow, and Ranch. The San Juan elevation
incorporates recessed windows, decorative shutters, wrought iron details, S concrete tile roofing, and
arched patio/entryway. The Bungalow incorporates flat tile concrete roofing, stucco finish, shutters, lap
siding, and brick veneer. The Ranch style incorporates louvered shutters, recessed windows, accents of
vertical siding, wood knee braces, and stone veneer.
Some of the plans incorporate a modest amount of wall plane articulation, and all plans incorporate
decorative garage doors to match the architectural style of the home. Each of the four plans feature
DRC AGENDA
DESIGN REVIEW DRC2011-00047 — MERITAGE HOMES
July 5, 2011
Page 2
•
covered porch entries that range in size dependent upon the style. Plan 2 has a side-on garage to meet
the 30 percent requirement that houses have side-on or recessed garages.
Staff Comments: The following comments are intended to provide an outline for Committee discussion.
Major Issues: The following broad design issues will be the focus of Committee discussion regarding this
project:
1. None at this time.
Secondary Issues: Once all of the major issues have been addressed, and time permitting, the
Committee will discuss the following secondary design issues:
1. None at this time.
Policy Issues: The following items are a matter of Planning Commission policy and should be
incorporated into the project design without discussion:
1. Boulders from the project site shall be utilized and integrated as part of the front yard Landscape
Plan per the Master Plan Resolution of Approval.
2. Driveways shall be colored and scored in a diagonal pattern for additional entryway detail.
Staff Recommendation: Staff recommends that the Design Review Committee recommend approval of
the project.
Design Review Committee Action:
Staff Planner: Steve Fowler
Members Present:
DESIGN REVIEW COMMENTS
7:20 p.m. Dominick Perez July 5, 2011
MINOR DEVELOPMENT REVIEW DRC2011-00155 - JASON LEE - A request to divide an existing
single-tenant building to accommodate three tenants within the Foothill Boulevard Community Commercial
District (Subarea 2), located at 8939 Foothill Boulevard - APN: 0208-192-07. Related files:
DRC2011-00468 and DRC2011-00469. This project is categorically exempt from the requirements of the
California Environmental Quality Act (CEQA) pursuant to State CEQA Guidelines Section 15301 (Class 1
Exemption - Existing Facilities).
Background: The existing single-tenant commercial retail building is located south of Foothill Boulevard,
approximately 170 feet east of Vineyard Avenue at 8939 Foothill Boulevard. In 2001, Non-Construction
Conditional Use Permit DRC2001-00335 was approved allowing for the establishment of a retail liquor
store at this location. The site contains sufficient parking and does not have any Municipal or
Development Code violations at this time.
Design Parameters: Currently, the existing 4,320 square foot building on-site incorporates a concrete tile
gable roof, river rock wainscot along the base of the front (north) elevation with stucco walls and
storefront glass surrounding the main entrance. The existing floor plan indicates that there is an office,
storage room, and retail/display area within the building with an entrance at the east end of the north
elevation.
The applicant is proposing to subdivide the existing 4,320 square foot single-tenant commercial retail
building into three units. In doing this, the north and west building elevations will be modified. The
proposed floor plan shows a total of three units; Unit 101 containing a total of 2,160 square feet, while
Units 102 and 103 each contain a total of 1,080 square feet. Each of the units will have a building
entrance at the north elevation. The submitted elevations indicate that the applicant will be utilizing the
existing concrete tile gable roof while also incorporating raised tower features, square columns covered
with river rock, a decorative wood trellis, as well as a new trash enclosure containing river rock walls that
is to replace the existing and slightly damaged trash enclosure.
The proposed roof plan shows the addition of two new tower structures, one at the north elevation and
one at the west elevation, which will both contain a flat concrete tile to match the existing tile used on the
building. This roof plan also shows a new parapet wall, which staff has verified that it does provide
sufficient screening of the proposed rooftop equipment.
The project meets the height and setback requirements of the Foothill Boulevard Community Commercial
District (Subarea 2). The proposed building modifications are architecturally compatible with the
neighboring development and conform to the design guidelines outlined in the Development Code,
including carrying materials and architectural features, such as river rock, flat concrete tile, and stucco
walls, to all elevations.
Staff Comments: The following comments are intended to provide an outline for Committee discussion.
Major Issues: The following design issues will be the focus of Committee discussion regarding this
project:
1. None. The applicant worked diligently with staff to follow the criteria outlined in the Development
Code. There are no major issues regarding this project at this time.
DRC AGENDA
MINOR DEVELOPMENT REVIEW DRC2011-00155 — JASON LEE
July 5, 2011
Page 2
Secondary Issues: Once all of the major issues have been addressed, and time permitting, the
Committee will discuss the following secondary design issues:
1. The building currently contains river rock wainscoting along portions of the front (north) elevation.
Staff recommends wrapping the river rock wainscot around to the north ends of both the east and
west elevations for an additional 8 feet along the base of the building as a means of satisfying the
360-degree architectural treatment as required per Section 17.10.060 of the Development Code.
Policy Issues: No policy issues at this time.
Staff Recommendation: Provided that the issues identified above are addressed to the satisfaction of
the Committee, staff recommends that the Minor Development Review be approved.
Design Review Committee Action:
Staff Planner: Dominick Perez
Members Present:
DESIGN REVIEW COMMENTS
7:20 p.m. Dominick Perez July 5, 2011
UNIFORM SIGN PROGRAM DRC2011-00469 - JASON LEE - A Uniform Sign Program for
Minor Development Review DRC2011-00155, a proposal to subdivide an existing single-tenant commercial
building into three units within the Foothill Boulevard Community Commercial District (Subarea 2), located
at 8939 Foothill Boulevard -APN: 0208-192-07. Related files: DRC2011-00155 and DRC201100468.
Background: The proposed sign program is for a project that will be subdividing an existing single-tenant
commercial building into three units, with a combined floor area of 4,320 square feet (Minor Development
Review DRC2011-00155). The site is located south of Foothill Boulevard, approximately 170 feet east of
Vineyard Avenue at 8939 Foothill Boulevard. Currently, the site is being occupied by a retail liquor store,
which was allowed for through the approval of Non-Construction Conditional Use Permit
DRC2001-00335 in 2001.
Design Parameters: Currently, the existing site contains one wall sign located on the north building
elevation, and one monument sign located within the planter area abutting the vehicular entrance of the
site from Foothill Boulevard.
The program proposes sign requirements for wall signs as well as the existing monument sign. There
are a total of 4 wall-mounted sign locations, three of which are on the north elevation and one on the
west elevation. Future tenants will be given two options for wall signs. The first option will allow for a
single row of text with a maximum letter height of 18 inches. The second option will allow for two rows of
text with a maximum overall height of 28 inches, maximum letter height of 12 inches, and minimum
spacing between rows of 4 inches. The minimum letter height for all wall signs is proposed at 8 inches,
and the maximum length of all wall signs shall be no greater than 70 percent of the approved sign facade
area. The program requires tenants to utilize 4-inch deep internally illuminated channel letters with
1/8-inch thick acrylic sign faces and 3/4-inch bronze trim caps. The existing monument sign utilizes a
river rock covered base with columns at each end with a wood lattice cap attached above the sign area
for an overall height of 8 feet. The program proposes three sign panels at 7 square feet each for an
overall sign area of 21 square feet per face.
The sign program meets the requirements set forth within the City's Sign Ordinance and is consistent
with recently approved commercial sign programs in regards to size and type. Additionally, the signs will
not be placed on any areas of the building that negatively impact any significant architectural features,
elements, or details.
Staff Comments: The following comments are intended to provide an outline for Committee discussion.
Major Issues: • The following design issues will be the focus of Committee discussion regarding this
project:
1. The Engineering Department is requiring an additional 19 1/2 feet of right-of-way dedication along
the property frontage for Foothill Boulevard. However, it appears that upon additional dedication of
Foothill Boulevard, a portion of the existing monument sign will be located within the right-of-way.
Therefore, staff recommends that the monument sign be relocated outside of the right-of-way within
the existing landscape planter abutting Foothill Boulevard, similar to what is indicated on Page 6 of
the submitted Sign program.
•
DRC AGENDA
UNIFORM SIGN PROGRAM DRC2011-00469 - JASON LEE
July 5, 2011
Page 2
Secondary Issues: Once all of the major issues have been addressed, and time permitting, the
Committee will discuss the following secondary design issues:
1. The sign program does not indicate the overall height of the monument sign. Staff recommends
the applicant revise the sign program to show the overall height of the monument sign. Note: Per
the Sign Ordinance, the maximum permitted height is 8 feet for the monument sign.
2. The sign program does not comment or set restrictions on the amount of monument panels that a
single tenant can occupy. Staff recommends that the applicant provide text within the sign program
allowing for a maximum of one panel, per tenant, per sign face. Note: Per the Sign Ordinance, the
maximum number of permitted panels on the monument sign is 3 per side, and the maximum total
number of signs (wall plus monument) any business may have is 3.
Policy Issues: The existing Conditional Use Permit (DRC2001-00335) for a 4,320 square foot liquor
store will need to be modified to be consistent with the reduction of square footage as proposed under
the Minor Development Review. The Minor Development Review will be conditioned to be consistent
with any conditions placed upon the CUP.
Staff Recommendation: Staff recommends that the Minor Development Review be approved, provided
that the issues identified above are addressed to the satisfaction of the Committee.
Design Review Committee Action:
Staff Planner: Dominick Perez
Members Present: