Loading...
HomeMy WebLinkAbout92-124 - Resolutions RESOLUTION NO. 92-124 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT NO. 92-23 FOR THE DEVELOPMENT OF AN UNMANNED RADIO DISPATCH FACILITY FOR MOBILE COMMUNICATIONS CONSISTING OF A 75-FOOT POLE AND ANTENNA AND 200 SQUARE FEET OF EQUIPMENT STORAGE WITHIN AN EXISTING BUILDING IN THE GENERAL INDUSTRIAL DISTRICT (SUBAREA 8) OF THE INDUSTRIAL AREA SPECIFIC PLAN, LOCATED AT 10700 JERSEY BOULEVARD, AND MAKING FINDINGS IN SUPPORT THEREOF - APN: 209-144-83 A. Recitals. (i) Smart SMR has filed an application for the issuance of the Conditional Use Permit No. 92-23 as described in the title of this Resolution. Hereinafter in this Resolution, the subject Conditional Use Permit request is referred to as "the application. " (ii) On the 23rd day of September 1992, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on the application and concluded said hearing on that date. (iii) All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2. Based upon substantial evidence presented to this Commission during the above-referenced public hearing on September 23, 1992, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: (a) The application applies to property located at 10700 Jersey Boulevard with a street frontage of approximately 630 feet and lot depth of 530 feet and is presently improved with an industrial building, parking facility, and landscaping; and (b) The property to the north of the subject site is developed with an industrial building, the property to the south of the site consists of an industrial building, and the properties to the east and west are developed with industrial buildings; and (c) The site is within the General Industrial District of the Industrial Area Specific Plan. PLANNING COMMISSION RESOLUTION NO. 92-124 CUP 92-23 - SMART SMR September 23, 1992 Page 2 (d) The monopole is located on the north side of an existing industrial building and will be surrounded on three sides by a 6-foot high masonry wall and on the remaining side by an existing trash enclosure wall. The perimeter of the wall will also be landscaped with trees. 3. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing and upon the specific findings of facts set forth in paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: (a) That the proposed use is in accord with the General Plan, the objectives of the Development Code, and the purposes of the district in which the site is located. (b) That the proposed use, together with the conditions applicable thereto, will not be detrimental to the public health, safety, or welfare or materially injurious to properties or improvements in the vicinity. (c) That the proposed use complies with each of the applicable provisions of the Development Code. 4. This Commission hereby finds and certifies that the project has been reviewed and considered in compliance with the California Environmental Quality Act of 1970 and, further, this Commission hereby issues a Negative Declaration. 5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth below: Planning Division: 1) Approval shall expire, unless extended by the Planning Commission, if building permits have not been issued within 24 months of this date. 2) The location of the pole shall be moved adjacent to the nearby trash enclosure. The tree along the west side of the enclosure shall be removed. A matching masonry wall shall be located along the west side of the pole and landscaped with one tree and shrubs. 3) As an alternative, if the above location is not feasible, then the pole shall be located in the same location as proposed but screened with a masonry block wall and landscaped. 4) The pole shall be of metal material and painted a gray color. PLANNING COMMISSION RESOLUTION NO. 92-124 CUP 92-23 - SMART SMR September 23, 1992 Page 3 Building and Safety: 1) Structural calculations based on the 1991 edition of the Uniform Building Code shall be provided for plan review. Wind loads, footing design, etc. , shall be verified. 2) In conjunction with the plan check submittal, the applicant shall provide the following information: a) Clarify if any hazardous materials in excess per Chapter 9, Tables 9A-B will be stored and/or used within the building. b) Clarify distance from adjoining property lines and buildings to tower. c) Provide existing occupancy types within building. 6. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 23RD DAY OF SEPTEMBER 1992. PLANNING CO., ISSION OF THE CITY OF RANCHO CUCAMONGA if ' BY: L a �a i aC Ss C arry Niel, Chairman i� ,_ or ATTEST: �/ d Bra711110rer, - - -ry I, Brad Buller, Secretary of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 23rd day of September 1992, by the following vote-to-wit: AYES: COMMISSIONERS: MCNIEL, MELCHER, VALLETTE NOES: COMMISSIONERS: NONE ABSENT: COMMISSIONERS: CHITIEA, TOLSTOY