Loading...
HomeMy WebLinkAbout2018-11-28 - Agenda Packet Supplemental - PC-HPCPlanning Commission November 28, 2018 Applicant GOLDEN AVENUE DEVELOPMENT Project Description TIME EXTENSION DRC2018-00816 -A request to allow for a one (1)year time extension of a previously approved Tentative Tract Map (SUBTT17444) Background and General Information •One year time extension of Tentative Tract MapSUBTT17444 •Originally approved on October 10,2007,for a 13-unitmulti-family development •Related Design Review DRC2005-00250 expired onOctober10,2012 •New Design Review DRC2013-00583 was approved onFebruary11,2015,and will expire on February 11 ,2020 •Complies will all requirements for the Low Medium (LM)District •The time extension is necessary to allow the City tocompletestormdrainimprovementson19thStreettoremoveprojectfromaFEMAfloodzone Approval Overview Tentative Tract Map 17444 Approval History Approving Authority Approval/Extension Type Approval Period Approval Date Expiration Date Planning Commission Original Approval 3 Years 10/10/07 10/10/10 Senate Bill 1185 Automatic Extension 1 Year 10/10/11 Assembly Bill 333 Automatic Extension 2 Years 10/10/13 Assembly Bill 208 Automatic Extension 2 Years 10/10/15 Assembly Bill 116 Automatic Extension 2 Years 10/10/17 Planning Commission Time Extension DRC2017-00755 1 Year 11/08/17 10/10/18 Planning Commission Time Extension DRC2018-00816 1 Year 11/28/18 10/10/19 Aerial Photo Tentative Parcel Map SUBTT17444 DRC2013-00583 Approved Layout Existing Drainage Flows Engineering Department Conditions of Approval •Engineering Condition 5a (to be eliminated):If the Federal Emergency Management Agency is unwilling to revise the Flood Insurance Rate Map, elevation certificates shall be provided for lots within the flood zone. •New Engineering Condition:If the applicant for this project chooses to wait for the City of Rancho Cucamonga to construct a public storm drain system and remove the proposed project from the flood plain as determined by FEMA,the applicant shall,as a condition of approval for the project,accept all remaining off -site storm water flows from the adjacent upstream property(ies).The storm water flows shall be conveyed through the project as a privately maintained storm drain system and shall connect to a public storm drain system in Archibald Avenue.The inlet system to intercept the off-site storm drain flows shall be a privately maintained curb type catch basin within the project boundary.All off -site improvements shall be coordinated with the adjacent property owner(s). Environmental Review •A Mitigated Negative Declaration was adopted on October 10,2007,in connection with the City’s approval of Tentative Tract Map SUBTT17444 •CEQA Guidelines Section 15162,states that no subsequent or supplemental review is necessary if the scope of the project has not changed from that considered as part of the original CEQA review Staff Recommendation •Staff recommends approval of Time Extension DRC2018- 00816 •All applicable Conditions of Approval in Resolution No.07- 59 shall apply to Time Extension DRC2018-00816,except for Engineering Department Condition of Approval 5a, which is no longer applicable and has been replaced with a new Engineering Department Condition of Approval