HomeMy WebLinkAbout2018/06/19 - Agenda Packet 91ri •JNIN�I
y
Gr 1
S B 8 i 6 � � F o r ��!'•� I
„orf
I. u`
i
JUNE 197 2018 - 7.00 P.M.
DESIGN REVIEW COMMITTEE AGENDA
RAINS ROOM
CITY HALL
10500 CIVIC CENTER DRIVE
A. CALL TO ORDER
Roll Cali: Ray Wimberly
Rich Macias
Candyce Burnett
Donald Granger
Alternates: Lou Munoz
Tony Guglielmo
Francisco Oaxaca
B. PUBLIC COMMUNICATIONS
This is the time and place for the general public to address the Committee on any item listed
on the agenda. State law prohibits the Committee from addressing any issue not previously
included on the Agenda. The Committee may receive testimony and set the matter for a
subsequent meeting.
Comments are to be limited to five minutes per individual or less, as deemed necessary by
the Staff Coordinator, depending upon the number of individuals members of the audience.
This is a professional businessmeeting and courtesy and decorum are expected. Please
refrain from any debate between audience and speaker, making loud noises or engaging in
any activity which might be disruptive to the decorum of the meeting.
C. PROJECT REVIEW ITEMS
The following items will be presented by the applicant and/or their representatives. Each
presentation and resulting period of Committee comment is limited to 20 minutes. Following
each presentation, the Committee will address major issues and make recommendations with
respect to the project proposal. The Design Review Committee acts as an advisory Committee
to the Planning Commission. Their recommendations will be forwarded to the Planning
Commission as applicable. The following items do not legally require any public testimony,
although the Committee may open the meeting for public input.
C1. DESIGN REVIEW DRC2017-00889 — KIDDIE ACADEMY — A request for site plan and
architectural review of a proposed 10„763 square foot child care facility with outdoor play areas
on a vacant site totaling 1.21 acres of land„ located in the Village Commercial (VC) District,
Victoria Planned Community, at the southwest corner of Atwood Street and Victoria Park Lane;
APN: 1089-581-09. Related fifes: Conditional Use Permit DRC2017-00890 and Tree Removal
Page 1 of 2
w
JUNE 1912018 7:00 P.m.
DESIGN REVIEW COMMITTEE AGENDA
RAINS Room
CITY HALL
10500 CIVIC CENTER DRIVE
Permit RC201 -00460. This item is exempt from the irequirements of the California
Environmental Quality Act(CEQA) and the City's CEQA guidelines under CEQA Section 15332
— In-Fill Development Projects,
C2, HILLSIDE DESIGN REVIEW DC2016-00672 —ANDRESEN ARCHITECTURE — A request
for site plan and architectural review of a proposed 6,175 square foot residential home and 674
square foot detached second dwelling unit on a vacant site totaling 12"044 square feet„ located
in the Low (L) Residential District in the Hillside Overlay District on the north side of Camino
Predera; APN: 0207-641-12. This item its exempt from the requirements of the California
Environmental Quality Act(CEQA) and the Ciity's CEQA guidelines under CEQA Section 15303
—New Construction or Conversion of Small Structures.
D. ADJOURNMENT
The Design Review Committee has adopted Administrative Regulations that set an 19:00 p.m,
adjournment time. If items go beyond that time, they shall be heard only with the consent of the Committee,
I, Lois J. Schrader, Planning Commission Secretary of the City of Rancho Cucamonga, or my
designee, hereby certify that a true,, accurate copy of the foregoing agenda was posted on
day, Wednesday, June 13„ 2018, at least seventy two (72) hours prior to the meeting per
Government Code 54954.2 at 10500 Civic Center Drive, Rancho Cucamonga, CA.
ZP
Lois J. Schrader
Planning Commission Secretary
City of Rancho Cucamonga
IsIf you need special assistance or accommodations to participate in this meeting„
please contact the Planning Department at (949) 477-2750. Notification of 48 hours
prior to the meeting will enable the City to make reasonable arrangements to ensure
accessibility. Listening devices are available for the hearing impaired.
Page 2 of 2
DESIGN REVIEW COMMENTS
7:00 p.m. Dat Tran June 19, 2018
DESIGN REVIEW DRC2017-00889 — KIDDIE ACADEMY — A request for site plan and
architectural review of a proposed 10,763 square foot child care facility with outdoor play
areas on a vacant site totaling 1.21 acres of land, located in the Village Commercial (VC)
District, Victoria Planned Community, at the southwest corner of Atwood Street and
Victoria Park Lane; APN: 1089-581-09. Related files: Conditional Use Permit DRC2017-
00890 and Tree Removal Permit DRC2018-00460. This item is exempt from the
requirements of the California Environmental Quality Act (CEQA) and the City's CEQA
guidelines under CEQA Section 15332 — In-Fill Development Projects.
Site and Surrounding Land Uses: The project site is within the Village Commercial (VC)
District of the Victoria Planned Community. The project site is located at the southwest
corner of Atwood Street and Victoria Park Lane. The site to the north of the project site,
on the opposite side of Atwood Court, is zoned Medium-High (MH) Residential District
and currently consists of a condominium complex. The site to the east of the project site
is zoned Village Commercial (VC) and consists of the Elevage apartment complex. The
sites to the south and southwest of the project site are also zoned Village Commercial
(VC) District and consist of a connected neighborhood shopping center and service
station. The project site shares a driveway access with the shopping center and service
station. The sites to the west of the project site, across from Victoria Park Lane, are in
the Low Residential (L) District and consists of single-family homes and undeveloped
land.
Proiect Overview: The applicant is proposing to construct a 10,763-square foot child
care facility on a vacant site totaling 1.21 acres. The site currently consists of a 70-stall
overflow parking lot for the use of the shopping center and service station to the south.
The parking lot will mostly remain as existing, except for some modifications to improve
circulation and to ensure ADA compliance. The parking lot will continue to service both
the shopping center and the proposed child care facility.
The building will be located on the north side of the site. The exterior of the building has
been designed to consist of visually-interesting fagades viewable from all vantage points.
The design incorporates the use of fiber cement board siding with stucco to break up the
expansive blank fagade. The roof consists of concrete tiles. The structure also
incorporates the use of wood rafters, wood trims, decorative windows and window
planters to add architectural interest to the building. Lastly, canopy roofs and a wooden
trellis structure has been added to the front of the building to further enhance the visual
quality of the building. Overall, the design of the building enhances the overall visual
quality of the site and meets the City's "360-degree" design standards.
The area in proximity of the building consists of a variety of play and outdoor
entertainment areas for the use with the building. This includes 2 rubberized playground
areas with play structures, a small soccer field, and decorative nature walkway areas.
The site also includes a variety of different surfaces: concrete, turf, paving and deck
areas that enhances the overall site design.
C1—Pg 1
DRC COMMENTS
DRC2017-00889 — KIDDIE ACADEMY
June 19, 201
Page 2
The site meets the City's Development Standards for parking, building heights and alt
associated setbacks. The proposed building and all play structures exceeds the
minimum setback of 25 feet allong Atwood Street and Victoria Park Lane. The building Is
set a minimum of 35 feet from all interior property lines, and all play structures are
setback a minimum of 5 feet from property lines. The number of parking spaces provided
for the site is 70 spaces and will meet the 50 parking spaces required for the proposed
child care facility. The remaining 20 parking spaces will be used for overflow parking for
the shopping center and service station, Altogether, the shopping center, service station
and child care facility will maintain an extra capacity of 6 parking spaces. There iiis no
landscaping minimum established for the WIlage Commercial (VC) District; however, the
total amount of landscaped areas onsite is roughly 21% and exceeds the 10-15%
landscaped areas required for most commercial districts in the City.
The proposed project includes a request to remove 58 trees from the site to
accommodate development and to configure the site to meet ADA standards. Of those
58 trees, 27 trees are part of a eucalyptus windrow and considered heritage trees under
the City's Development Code, The remaining trees consists of Magnolia, Aleppo Rine
and Chinese Flame trees. Magnolia, Aleppo Pine and Chinese Flame trees are only
considered heritage trees if they are part of a stand of trees dependent on one another
for survival or if they exceed a minimum height of 30 feet and have a total diameter of 20
finches or more as measures from 4 X2 feet above ground. An arborist report prepared for
the site determined that none of the trees were ecologically dependent on one another.
The arborist report also determined that of the remaining 31 non-eucalyptus trees, only
one Aleppo Pine is large enough to be considered a heritage tree, bringing the total
number of heritage trees to be removed to 28. The proposed development will retain 30
trees onsite, including a eucalyptus windrow consisting of 15 trees along the north
property line. An additional 33 trees will be planted to meet the required parking lot and
site tree requirements. Overall, the site will have 25 fewer trees than existing.
Staff Comments:
Major Issues:
1. None. Staff supports the proposed site layout and overall design of the proposed
project. The project is well-integrated into the existing parcel. The buildings
consist of visually-interesting fagades which meet the City's 360-degree design
standards. The building fagade incorporates a variety of materials and
architectural features, including fiber cement board siding, decorative wood
rafters and wood trellises, thereby meeting the City's design standards for
commercial developments. Adequate parking is provided onsite for the proposed
building and landscaping is maintained to adequately screen the site from the
public right-of-way, reducing any visual impact upon public roadways.
Secondary Issues:
1. None
C1—Pg 2
DRC COMMENTS
DRC2017-00889— KIDDIE ACADEMY
June 19, 2018
Page 3
Policy Issues: The following items are a matter of Planning Commission policy and
should be incorporated into the project design without discussion:
1. All Double Detector Checks (DDC) and Fire Department Connections (FDC) required
and/or proposed shall be installed at locations that are not within direct view or line-
of-sight of the main entrance. The specific locations of each DDC and FDC shall
require the review and approval of the Planning Department and Fire Construction
Services/Fire Department. All Double Detector Checks (DDC) and Fire Department
Connections (FDC) shall be screened behind a 4-foot high block wall. These walls
shall be constructed of similar material used on-site to match the building.
2. All ground-mounted equipment, including utility boxes, transformers, and back-flow
devices, shall be surrounded by a minimum of two rows of shrubs spaced a minimum
of 18 inches on-center. All ground-mounted equipment shall be painted dark green
except as directed otherwise by the Fire Department.
3. All wrought iron fences and sliding gates shall be painted black or similarly dark
color.
Staff Recommendation: Staff recommends that the project move forward to the
Planning Commission for final review and action.
Design Review Committee Action:
Project was approved as presented and forwarded to Planning Commission
Staff Planner: Dat Tran, Assistant Planner
Members Present: Commissioner Ray Wimberly; Commissioner Lou Munoz; Donald
Granger, Senior Planner
C1—Pg 3
DESIGN REVIEW COMMENTS
7:00 p.m. Dat Tran June 19, 2018
HILLSIDE DESIGN REVIEW DRC2016-00672 —ANDRESEN ARCHITECTURE —A request for
site plan and architectural review of a proposed 6,175 square foot residential home and 674
square foot detached second dwelling unit on a vacant site totaling 12,044 square feet, located
in the Low (L) Residential District in the Hillside Overlay District on the north side of Camino
Predera; APN: 0207-641-12. This item is exempt from the requirements of the California
Environmental Quality Act (CEQA) and the City's CEQA guidelines under CEQA Section 15303
— New Construction or Conversion of Small Structures.
BACKGROUND
Site and Surrounding Land Uses: The 12,044-square foot vacant project site is located on the
north side of Camino Predera and south of Red Hill Country Club Drive, in the Low (L)
Residential District and within the Hillside Overlay District. The property dimensions are
approximately 82 feet along the north property line, 138 feet along the east property line, 139
feet along the west property line and 92 feet along the south property line. The upward slope lot
has an elevation height of approximately 1,332 feet as measured at the curb face along the
south property line and an elevation height of approximately 1,364 feet at the north property
line, for a total grade change of 32 feet from the north to south property lines. The site shares a
common property line with developed, single-family lots to the north, west and east. The lot to
the south, on the other side of Camino Predera, is currently vacant. The street improvements
have been installed along Camino Predera, except street trees and parkway landscaping.
Project Overview: The applicant is requesting to construct a 6,175-square foot, three-story,
single-family residence on the project site. The project complies with the requirements of the
Low (L) Residential District. The required front yard setback is 37 feet, the required side yard
setbacks are 5 and 10 feet and the required rear yard setback is 20 feet. The proposed front
yard setback is 53 feet, the side yard setbacks are 5 and 10 feet, and the rear yard setback is
41 feet. Lot coverage is approximately 34 percent, below the maximum permitted lot coverage
of 40 percent. The overall building height is 30 feet, which is at the maximum permitted 30-foot
height limit within the Hillside Overlay District. The project also includes a second dwelling unit
at the rear of the lot. The second dwelling unit is 674 square feet. Solid roof structures located
in the rear yard are allowed to be up to 5 feet from the side and rear property line. The second
dwelling unit is setback 5 feet from the rear property line, 18 feet from the east side property line
and 20 feet from the west side property line. The overall height of the second dwelling unit is 16
feet and meets the maximum height allowed for solid roof structures in the rear yard. The
project also includes front yard and rear yard areas typical on residential lots. The front yard
maintains 52% landscaping, exceeding the 50% minimum required per Development Code
Section 17.56.070.
The proposed 6,175 square foot residence consists of three levels. The first level is 1,231
square feet and consists of a subterranean 3-car garage and various storage areas. The ground
floor is 3,055 square feet and consists of first floor living space, a rear yard covered patio and a
covered main entry. The upper floor is 1,889 square feet and consists of the remaining living
spaces and includes two covered decks at the front of the residence. The size of the residence
is in keeping with homes constructed along Camino Predera. The homes on the north side of
C2—Pg1
DRC COMMENTS
HILLSIDE DESIGN REVIEW RC2016-00672
ANESEN ARCHITECTURE
June 19,2018 . .............
Page 2
Camino Predera constructed prior to the year 2000 average approximately 2,400 square feet in
size. Since the year 2000, the houses on Camino Predera have been larger, ranging in sizes
between 3,628 square feet to 4,896 square feet. The overall size of the proposed residence is
larger than previously approved sizes. However, because the garage its located underground,
the size of the residence above ground its 4,944 square feet.
Hillside Design & Code Compliance: The project complies with the intent of the Hillside Overlay
District, which seeks to facilitate appropriate development of hillside areas. The project site is an
upslope lot with an elevation change of approximatelly 32 feet from the north to south property
lines. Due to the change in grade, staff required the residence to be aligned with the natural
contours of the land. The primary residence has been terraced to follow the slope.. Roof levels at
the front of the residence are located at a lower level) than roof levels at the rear of the
residence. The building makes use of split pads and grade separations to permit the structure to
step up with the natural slope. Design elements such as front-facing roof gables were not
allowed at the front of the residence. The maximum height of the building is 15 feet at setbacks
and 30 feet overall as measured from finished grade. Hillside Design Section 17.122,020.D.11.0
requires that residences in the Hillside Overlay District be designed to fit within a 30-foot high
building envelope. Furthermore, the building's garage is subterranean and designed to reduce
the overall scale and massing of the building. During the review process, the applicant proposed
a number of different building layout and grading designs designed in order to reduce view
obstruction as seen from the residences to the north. The previous designs included a larger
residence and a grading design with larger retaining walls that exceeded height limits. The
current design implements the best practices of hillside design that serves to mitigate view
impacts.
The Development Code does not include a view preservation ordinance, though the applicant
has designed the residence to limit view obstructions as much as feasible. The residence has a
maximum height of 41 feet above the adjacent street curb and is lower in height to the existing
residence along the north and east property line.
Architecture: The proposed residence has a contemporary design theme, which includes a flat
roof, smooth stucco finish, metal railings with glass panels, and copper roofing. The proposed
residence allso incorporates stone veneer, decorative wood trims and fascia, and decorative
garage doors. In addition to materials, the residence incorporates multiple wall planes, windows
and variations in roof height to break up blank expanse of stucco along the side and rear
elevations. The variations in roof height helps the residence remain in compliance with Hillside
Design Guidelines Section 17.122.020. .2, minimizing the appearance of overbuilding and the
blocking of views. The building mass is broken up though multiple wall plane changes and the
incorporation of exterior decks and patio areas along the front and rear elevations. The
residence will be painted earth tone colors, meeting Hillside Design Guideline Section
17.122.020.D.2. The design of the residence is compatible with the other residences along
Camino Predera, which iiincludes a variety of architectural styles.
Second Dwelling Unit: The second dwelling unit at the rear of the lot incorporates similar styles
to the main residence. The unit includes a flat roof, stucco finish, and a variety of decorative -
wood and metal trims The unit is also improved with glass windows and doors on three sides to
break up blank wall expanses and to provide natural lighting for the unit. Similar to the main
C2—Pg2
DRC COMMENTS
HILLSIDE DESIGN REVIEW DRC2016-00672
ANDRESEN ARCHITECTURE
June 19, 2018
Page 3
residence, the unit is dug into the hillside which reduces the scale and massing of the building
and helps to protect the view of the residence to the north.
General Onsite Improvements: The front yard consists roughly 48% of hardscape area, which
includes a winding driveway up to the garage. The driveway consists of grades up to 6 percent
slope. The driveway largely follows the contours of the land as the grade ascends and
minimizes cut-and-fill to the dirt levels. The wall is flanked by a series of retaining walls
generally between 3-4 feet, and not exceeding 6 feet in height, to retain dirt on the other side of
the wall. Per Hillside Development Standard 17.122.020.C.1.d, driveways with grades up to 20
percent are permitted when they are aligned with the natural contours of the lot and are
necessary to achieve site design goals. The contour design of the driveway allows for the slope
level to remain beneath the maximum permitted and to maintain minimal wall heights at the front
of the residence.
The applicant is also proposing retaining walls in the side and rear yard of the property. The
proposed walls are between 3-4 feet in height. The walls are 3 feet apart and meet the minimum
separation requirement per Development Code Section 17.48.030. In addition to rear and side
retaining wall, the applicant is proposing a new wrought iron fence along the rear property line.
The wrought iron fence will replace an existing chain-link fence and improve the visual quality of
the site. Furthermore, the wrought iron fencing is in keeping with Hillside Design Guideline
Sections 17.122.020.E, which encourages the use of open-view fencing to reduce view
obstruction.
Grading: The proposed grading design limits earth work to 2,400 cubic yards of export from the
project site, with most of the export necessary to underground the garage and to provide for a
flat, usable rear yard between the house and the second dwelling unit. The proposed grading
work around the perimeter of the site is less intensive and will involve minimal export of soil.
The result is a higher grade level around the perimeter, requiring the use of retaining walls to
hold back the dirt from the usable areas of the rear yard.
The foundation of the residence consists of an upper pad with an elevation of 1,352 feet and a
lower pad for the garage at 1,341 feet. The split pad is in conformance with Hillside Design
Section 17.122.020.D.1.a, which requires terracing of the building to follow the slope.
Undergrounding the garage necessitated the use of an up to 6-foot high retaining wall to retain
dirt for the driveway. The height of the wall is in conformance with Hillside Design Section
17.122.020.G.1.j.iv, which permits retaining walls over 8 feet that are an integral part of the
structure.
The proposed grading includes up to 18 feet of cut and 7 feet of fill. Projects in the Hillside
Overlay District requiring 5 feet of cut or fill is required to be reviewed by the Planning
Commission. The additional cuttfill is necessary due to the steepness of the lot.
Landscape: The proposed landscaping is designed to comply with Hillside Development Section
17.122.020.F. including the use of drought tolerant landscaping to protect slopes from erosion
and planting shrubs to soften the views of the upslope elevations. The project is not within the
High Fire Hazard Zone or within a wildland-urban interrace area. The proposed landscaping
also complies with the front yard landscape requirements, including reducing hardscape to less
C2—Pg3
DRC COMMENTS
HILLSIDE DESIGN REVIEW DRC2016-00672
ANDRESEN ARCHITECTURE
June 19, 2018 ............
Page 4
than 50 percent of the front yard area. Landscaping the rear half of the lot is designed to
minimize grading and includes the planting of various plants and a decorative fountain.
Neighborhood Meeting: The applicant held a neighborhood meeting at Valley Vista Elementary
on May 22, 2018, with approximately 16 people in attendance, not including the applicant and
owner. The applicant provided an overview of the project and fielded questions. The questions
were primarily directed towards the technical details of the project including the height of the
structure, the size of the residence, the setbacks of the residence, and the earthwork quantities
involved. Residents also had questions regarding the City's policies and standards regarding
the establishments of new homes in the neighborhood. The overarching concern raised was the
potential view loss created by the height and size of the proposed residence and by the
proposed landscaping. The existing residents stated that their concerns were driven by the
newer residences along Camino Pneer a that were approved over the last 20 years, which they
felt were not in keeping with the intent of the Hillside Overlay District and with the older
residences in the area.
DESIGN COMMENTS
Staff Comments: Staff is in support of the architectural, site and grading design for the proposed
6,175 square foot residence and 674 square foot second dwelling unit. The project conforms
with the Development Code and the Hillside Design Standards and Guidelines, including
providing a grading design that balances the requirement to reduce cut and fill to the greatest ..........
extent possible and reduces the height of the structure to limit view obstructions as seen from
the adjacent residences. The proposed design reduces the height of the main residence to just
over 30 feet above the height of the adjacent grades. The residence is stepped with the existing
grade and includes a subterranean garage, further reducing the overall bulk as seen from
Camino Predera, Both the primary residence and secondary dwelling unit meet the side and
rear yard setbacks per the Development Code. The residence is well-designed and carries the
design theme to all elevations, which includes variations in the height of the roofline and wall
planes and the extensive use of decorative secondary materials. The proposed design does not
require Variances or Minor Exceptions and is in keeping with the more recent residences
constructed along Camino Predera.
Major Issues: one
Second a DLLss ues: None
Staff Recommendation- Staff recommends that the Committee review the project and provide
comments as warranted. If the Committee finds the project acceptable, staff recommends that it
be forwarded to the Planning Commission for review and action.
C1 — Pg4
C2—Pg4