HomeMy WebLinkAbout2019-07-02 DRC AgendaI’
JULY 2,2019 -7:00 P.M.
DESIGN REVIEW CoMMITTEE AGENDA
RAINS ROOM
CITY HALL
10500 CIVIC CENTER DRIVE
A.CALL TO ORDER I
Roll Call:Ray Wimberly
Tony M.Guglielmo
Elisa Cox
Mike Smith
Alternates:Lou Munoz
Francisco Oaxaca
B.PUBLIC COMMUNICATIONS I
This is the time and place for the general public to address the Committee on any item listed
on the agenda.State law prohibits the Committee from addressing any issue not previously
included on the Agenda.The Committee may receive testimony and set the matter for a
subsequent meeting.
Comments are to be limited to five minutes per individual or less,as deemed necessary by
the Staff Coordinator,depending upon the number of individuals members of the audience.
This is a professional businessmeeting and courtesy and decorum are expected.Please
refrain from any debate between audience and speaker,making loud noises or engaging in
any activity which might be disruptive to the decorum of the meeting.
I C.PROJECT REVIEW ITEMS I
The following items will be presented by the applicant andlor their representatives.Each
presentation and resulting period of Committee comment is limited to 20 minutes.Following
each presentation,the Committee will address major issues and make recommendations with
respect to the project proposal.The Design Review Committee acts as an advisory Committee
to the Planning Commission.Their recommendations will be forwarded to the Planning
Commission as applicable.The following items do not legally require any public testimony,
although the Committee may open the meeting for public input
Cl.COURTESY REVIEW DRC2O1 9-00475 —PAUL MUKAI -A request to replace an existing
composition shingle roof with a standing seam metal roof,on an existing single-family residence
within the Low (L)Residential District,located at 7874 Buena Vista Drive.This item is exempt
Page 1 of 2
—CrCrr~C((Cf
r ,r 1r
JULY22019-7:OOP.M.
DESIGN REVIEW C0MMrrrEE AGENDA
RAINS ROOM
Crr~HALL
10500 Civic CENTER DRIVE
from the requirements of the California Environmental Quality Act (CEQA)and the City’s CEQA
guidelines under CEQA Section 15301 —Existing Facilities.
I D.ADJOURNMENT I
The Design Review Committee has adopted Administrative Regulations that set an 11:00 p.m.
adjournment time.If items go beyond that time,they shall be heard only with the consent of the Committee.
I,Valerie Victorino,Executive Assistant,of the City of Rancho Cucamonga,or my designee,
hereby certify that a true,accurate copy of the foregoing agenda was posted on
Thursday,June 27,2019 at least seventy two (72)hours prior to the meeting per Government
Code 54954.2 at 10500 Civic Center Drive,Rancho Cucamonga,CA.
~If you need special assistance or accommodations to participate in this meeting,
please contact the Planning Department at (909)477-2750.Notification of 48 hours
prior to the meeting will enable the City to make reasonable arrangements to ensure
accessibility Listening devices are available for the hearing impaired.
Page 2 of 2
DESIGN REVIEW COMMENTS
7:00 p.m.Sijifredo Fernandez July 2,2019
COURTESY REVIEW DRC2019-00475 —PAUL MUKAI -A request to replace an existing
composition shingle roof with a standing seam metal roof,on an existing single-family residence
within the Low (L)Residential District,located at 7874 Buena Vista Drive.This item is exempt
from the requirements of the California Environmental Quality Act (CEQA)and the City’s CEQA
guidelines under CEQA Section 15301 —Existing Facilities.
Site Characteristics:The project site is residential property located at 7874 Buena Vista Drive
within the Low (L)Residential District and the Hillside Overlay District.The location of the site is
within an area of the City that is referred to as “Red Hill”.The property is improved with a one-
story single-family residence of about 2,800 square feet.Due to the street layout at the subject
location,the house is bound on the east and west by Buena Vista Drive and Calle Casino
(respectively),and on the south by the intersection of these streets.To the north and east are
single-family residences.To the west and southwest of the site is the Red Hill Country Club
Golf Course.
Proiect Overview:The applicant,on behalf of the homeowners,is requesting to replace the
composition shingle roof of his clients’residence with a metal roof.At the time of this report,the
shingle roof had been removed.The metal roof will be a standing seam panel system.
Standing seam roofing is defined as a concealed fastener metal panel system that features
panels with vertical fins and a wide,flat area between the two fins.It’s also described as having
raised seams,or vertical legs,that rise above the level of the panel’s flat area.The color of the
proposed standing seam metal roof will be keystone grey (as shown in the attached exhibits).
The homeowners are requesting a metal roof to enhance the appearance of the house and to
facilitate drainage of the rainwater that is currently collecting on the due shallow pitch of the
house.
Regulatory Background:Per Section 17.36.010(F)of the Development Code “all existing
development within Residential Zoning Districts shall have roofing material made of tile,or the
imitation thereof,but not including composition shingles.Other roofing materials such as
metal,slate,or the imitation thereof,but not including composition shingles,may be approved
by the approval authority if it is determined that the roof material enhances the building
design.Any replacement of existing roofing materials shall be consistent with the existing
material or upgraded to a higher quality roofing material.For example,a composition
shingle roof can be replaced with composition shingles or can be upgraded to higher quality
roofing material such as tile or slate.”
Metal roofing is sometimes used in commercial and industrial applications (in the City).Such
roofing material on houses (in the City)are not common.And requests for installing metal
roofing as a re-roofing solution are rare.The design of them can vary,as well.Staff forwards
such requests,when they occur,to the Design Review Committee for their review and
consideration.The most recent request was for a metal roof system that had panels with a
granular texture that was non-reflective.As a result,the panels appear like a typical tile roof.
The Committee approved this request.However,the Committee indicated to Staff that they
wanted to continue to review proposals for metal roofing (unless they were similar to that which
they had just approved).
DRC COMMENTS
COURTESY REVIEW DRC2O19-00475 -PAUL MUKAI
July 2,2019
Page 2
Staff Comments
The architecture and typology of the houses in the Red Hill neighborhood is eclectic.They were
constructed over a broad timeframe that reflects the changes in technology,favored
architectural style,or a homeowner’s personal taste.There is no established architectural
theme that is required for new houses in Red Hill.The proposed residence has a California
Ranch design theme which is characterized by a single story,generally rectangular floor plan
and,often,a low-pitched roof.
Due to the eclectic architecture and typology,and the low pitch of the roof,Staff supports use of
a metal roofing material.Furthermore,the low roof renders other roofing material impractical.
The design of the roofing system will be architectural compatible with the design of the house
and the neighborhood nor negatively affect the neighborhood.The proposed color,keystone
grey,is compatible with the colors used on houses elsewhere in the neighborhood.
Staff Recommendation:Staff recommends that the Committee approve the design of the metal
roofing material as a replacement for the roofing material that was previously on the subject
house.
Staff Planner Sijifredo Fernandez,Contract Planner
Staff Coordinator:Mike Smith,Principal Planner
S
0 kdifteduraUsb~iral staridln9 seam roof panel
0PanelCoverage:l2”16”orlB”
0’RlbHelghtl4/4”
0 Gauges:26 ga.and 24 ga.standard,22 ga.optional
0 Snap-together panel system with fadory-appiled side lap sealant
0 Mlnfrnum roof alopeoveropenframln9 3:12
0 Mkihnum roof slope over solid substrate 1:12
0’Concealed dip designed for unlimited thermal movement
0 Accommodates up to4”blanket insulation
0’Finishes:PVDF,MSColocfast45’andAuyilctoatedGalvalumt
0’Contact Metal Sales for load-carrying capabilities
V~:i S~;irii His
>Ill.263,FIt Rai~s*ioe RiSig -pa eesr~
>IA 580,Can 90 Mid Ur4fi,Cauerdmi,~54,~5,261,303,34Z 343,
436,445,446,447,445.508 ad SCM
UL790,classAFi.Rss~ics Rdrg -pa nu.ty
V’UL2216.Qass 4 krQedRaWaroe
D’ASmEl5e2RoorLkIft
>ASINE1S45WWPGMSI*m
>AsuIEle60AkLiaage
>kbThOa CairdyA~powd,NOA 130906.05
>Tot.D.~I,.,4dwsxwa Evahia*n Rapod.RC-412
>icc Evab~i Rscot ESR-2385
D’2Ol4FSCApprowd
-26gt obaitrpWxd.11560.12 ~ir Pnq
-24 go.ova It?F~od,11560.l0(lrPnq
-24ga.ova Ii?P~’wood,11560,11 (i&Panic
-0.03?Mr*uii ova 7115’058,146451(15’Panic
-0.03?Mfloii ova If?Plywood,14645.7(15’P.4
0 kthfteduratlstudural Integral standing itb roof system
0’Snap-together panel system
016”panel coverage,major rib:8”centers,1.5/8”rib height
0’Gauges:26 ga,24 ga.standard,arid 22 ga optional
0’Mlnhnum roof slope:1:12
0’Applies over open framing or solid substrate
0’Concealed dip designed for thermal movement
0’Accommodates up to4’blanket insulation
0’Finishes:PVDF and Acrylic Coated Galvalume’
0’Coated Metal Sales for bad-carrying capabilities
>Ul,flFfreB~al...Rflq-perasa
>UL5WGm90MdU*Ca~%I588ad556A
>1L790,CImAFflRWIIWC.Ratq-paaSefftly
>Lii.1887,UpinTa lot Root CoverIng Spars
I>Ui~la,t~ass 4 In’ød Reebw~e
>ASTME 1502 Root L$ft
>A8Th4 E 1560 Ak Lidroge
>ict Ewdra5on Rscort ESR.2385
1216”onlB”Coversge
0’Square Batten Cap option for Vertical Seam Panel
0’AvaIlable at the Fontana Branch only
1-5/5’r-i
1.7/sf
1r~1rulrCoverage
12’j6”ortO”Coverage
1-3/4fh
-3/4”~
~rw~/iA
1-51rL
..
16”Coverage fri