HomeMy WebLinkAbout2459-DGENERAL NOTES
1 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
RANCHO CUCAMONGA STANDARDS AND THE STANDARD SPECIFICATIONS FOR
PUBLIC WORKS CONSTRUCTION CURRENT EDITION, INCLUDING ITS ANNUAL
SUPPLEMENTS OR AMENDMENTS. CONTRACTOR SHALL BE FAMILIAR WITH AND
SHALL BE RESPONSIBLE FOR ADHERENCE TO THESE STANDARDS AND
SPECIFICATIONS.
2. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND, TELEPHONE OR POWER
POLES, WATER METERS, VALVES, FIRE HYDRANTS, ETC., SHOWN OR NOT
SHOWN ON THESE PLANS WITHIN THE RIGHT-OF-WAY LIMITS OR IN ADJACENT
AREAS WHERE IMPROVEMENT WORK IS TO BE DONE SHALL BE REMOVED,
REPLACED, RELOCATED OR PROTECTED IN PLACE AS REQUIRED AT NO COST
TO THE CITY OF RANCHO CUCAMONGA.
3. ANY CONTRACTOR PERFORMING WORK ON THIS PROJECT SHALL FAMILIARIZE
HIMSELF WITH THE SITE AND SHALL BE SOLELY RESPONSIBLE FOR ANY
DAMAGE TO EXISTING FACILITIES RESULTING DIRECTLY OR INDIRECTLY FROM
HIS OPERATIONS, WHETHER OR NOT SUCH FACILITIES ARE SHOWN ON THE
PLANS.
4. A PERMIT SHALL BE OBTAINED FROM THE CITY OF RANCHO CUCAMONGA
PUBLIC WORKS ENGINEERING DEPARTMENT PRIOR TO ANY ENCROACHMENT OR
CONSTRUCTION WITHIN ANY CITY OF RANCHO CUCAMONGA EASEMENT OR
RIGHT-OF-WAY.
5. ALL GRADE STAKES SHALL BE SET BY THE CONTRACTOR OR ENGINEER.
PAVING STAKES SHALL BE SET AT ALL HINGE POINTS, EDGE OF PAVEMENT
POINTS WITHIN 0.01 FOOT OF SUBGRADE ELEVATION AND AT NOT MORE THAN
50 FOOT INTERVALS. ADDITIONAL PAVING STAKES MAY BE REQUIRED BY
CITY ENGINEER, AS NEEDED, AT WARPED OR VERTICAL CURVE AREAS.
6. ALL SEWER WATER, ELECTRIC, GAS, PHONE OR OTHER UTILITY LATERALS,
MAINS, OR SEWER,
SHALL BE CONSTRUCTED PRIOR TO PAVING.
7. COMPACTION TESTS OF EMBANKMENT CONSTRUCTION, TRENCH BACKFILL,
COMPACTING ORIGINAL GROUND AND ALL SUBGRADES SHALL BE PERFORMED
AT NO COST TO THE CITY OF RANCHO CUCAMONGA. A WRITTEN REPORT
WITH THESE COMPACTION TESTS SHALL BE SUBMITTED TO THE CITY ENGINEER
FOR APPROVAL PRIOR TO THE PLACEMENT OF BASE MATERIALS AND/OR
SURFACING.
8. AT THE COMPLETION OF PAVING, A MATERIALS REPORT SHALL BE SUBMITTED
TO THE CITY ENGINEER, LISTING ALL TESTS OR DETERMINATIONS COMPLETED
TO VERIFY STABILITY, OIL CONTENT AND GRADATION OF ASPHALT PAVING.
9. PRIOR TO INSTALLATION OF ANY PAVING, A MATERIALS REPORT SHALL BE
SUBMITTED TO THE CITY ENGINEER, LISTING ALL TESTS OR DETERMINATIONS
COMPLETED TO VERIFY: R-VALUE, SIEVE ANALYSIS AND SAND EQUIVALENT
OF AGGREGATE BASE.
10. PAVING SHALL BE PERFORMED IN ACCORDANCE WITH R-VALUE AND
PAVEMENT TESTS TAKEN TO DETERMINE STRUCTURAL SECTIONS.
11. WHEN IMPROVEMENTS ARE TO BE PLACED ON NATIVE SOIL, WHICH CONSISTS
OF A ROCKY MATERIAL, THE SUBGRADE SHALL BE PREPARED BY REMOVING
ALL ROCKS WHICH PROTRUDE ABOVE THE SUBGRADE, AND ALL VOIDS OR
DEPRESSIONS SHALL BE FILLED WITH A FINE GRADE MATERIAL OF A QUALITY
BETTER THAN THE NATIVE MATERIAL.
12. IF THE ASPHALT CONCRETE IS TO BE PLACED ON SUBGRADE, A SOILS
STERILANT REGISTERED BY THE E.P.A. FOR USE UNDER A.C. AND P.C.C.
SHALL BE UNIFORMLY APPLIED AT THE MANUFACTURER'S RECOMMENDED RATE
FOR THE FULL PAVEMENT WIDTH PRIOR TO PAVING.
13. ESTIMATE OF QUANTITIES IS PROVIDED BY THE ENGINEER ONLY FOR THE
CONVENIENCE OF THE DEVELOPER. THE CONTRACTOR SHALL MAKE HIS OWN
DETERMINATION OF CONSTRUCTION QUANTITIES BEFORE SUBMITTING A BID.
ANY ITEM OF WORK REQUIRED BY THESE PLANS WHICH IS NOT SPECIFICALLY
LISTED IN THE ESTIMATE OF QUANTITIES SHALL BE CONSIDERED AS INCLUDED
IN THE OTHER ITEMS OF WORK.
14. STREET SIGNS PER CITY OF RANCHO CUCAMONGA STANDARD NUMBER 401
SHALL BE CONSTRUCTED AT EACH INTERSECTION,
15. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM
RESPONSIBILITY FOR THE CORRECTION OF ERROR AND OMISSION DISCOVERED
DURING CONSTRUCTION. UPON REQUEST, THE REQUIRED PLAN REVISIONS
SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL.
16. WORK SITE AND EXTERIOR STREETS SHALL BE IN A NEAT, CLEAN, HAZARD
FREE, ORDERLY STATE, THROUGHOUT CONSTRUCTION, SITE SHALL BE CLEANED
UPON REQUEST OF THE INSPECTOR.
17. CONTACT ALL UTILITY COMPANIES, AS REQUIRED, 48 HOURS PRIOR TO
EXCAVATION.
18. ALL STRUCTURAL CONCRETE TO BE USED WITHIN SAN BERNARDINO FLOOD
CONTROL RIGHT-OF-WAY SHALL BE 4,000 PSI WITH "A" GRADATION IN ALL
INVERTS AND 4,000 PSI WITH "B" GRADATION IN ALL WALLS. CONCRETE FOR
ROCK INLET AND OUTLET STRUCTURES, BOTTOM CONTROL, SPLASH PADS AND
OTHER PROPOSED STRUCTURES SHALL BE 560E OR C3250.
19. ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTIVI
A-615 AND SHALL BE GRADE 60.
m-Nows
MIAMI
11 V
CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
NOTE A. CONTRACTOR TRA CTOR To ADJUST
OR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
EAFTER FINAL PAVING HAS BEEN INSTALLED.
ott INSTALL 36- RCP (D-LOAD AND PROFILE AS SHOWN ON PLANS) . ................. ......... 77 LF
063 CONSTRUCT JUNCTION STRUCTURE PER DETAIL ON SHEET I . .... 1 EA
IiJI SAWCUT AND REMOVE EXISTING PAVEMENT AND REPAIR TRENCH PER CITY OF RANCHO CUCAMONGA STD, 120 ..... ..700 SF
oI TRENCH EXCAVATION AND BACKFILL PER DETAIL ON SHEET 2 ........... .700 SF
LEGEND
EXISTING R/W
PROPOSED R/W
LOT LINE
CENTER LINE
FIRE HYDRANT
FL PROPERTY LINE
R/W---. RIGHT OF WAY
Q .... CENTERLINE
BOT. BOTTOM
SD STORM DRAIN
SMH ........... SEWER MANHOLE 48"
STD STANDARD LONGITUDINAL BARS: 12" 24"
SEW SEWER #4 0 13" O.C.,
TYP. TYPICAL FRONT AND BACK LONGITUDINAL BARS, 5"
IMP. IMPROVEMENT 1 #4 0 13- O.C., CUT
P.I.P. ... PROTECT IN PLACE & BEND A
DWG DRAWING VERTICAL BARS, #8 C 7" 4" R.
EXIST., . ....... EXISTING ----- — --
O.C. (FRONT) AND #8 @
14" O.C, & #5 @ 14- O.C. VERTICAL BARS: #8 0
RW RECYCLED WATER e
INV INVERT OF PIPE STAGGERED (BACK) 14" O.C. & #5 @ 14"
O.C.STAGGERED, LIT UTILITY cul
CUT VERTICAL BARS
CVWD ........... CUCAMONGA VALLEY #8 AT BREAKOUT LIMIT,
WATER DISTRICT ALONG HORIZONTAL CUT & BEND #5
SPPWC.STANDARD PLANS FOR CENTERLINE VERTICAL BARS: #8 @ 7" . . . . . . . ....
PUBLIC WORKS CONSTRUCTION O.C., CUT AT BREAKOUT
LIMfT A
PROPOSED STORM DRAIN
LONGITUDINALBARS:
EXISTING SEWER CUT HORIZONTAL BARS#4 @ 13 O.C., CUT
........ . ------- EXISTING WATER ALONG VERTICAL & BEND
CENTERLINE
EXISTING RECYCLED WATER
CST Ll�il
. ..... EXISTING STORM DRAIN
----------- -
EXISTING GAS
EXISTING TELEPHONE
EXISTING ELECTRICAL
EASEMENT
12" ?A
7 >- VERTICAL BARS: - 5
(N F- VERTICAL BARS: #5 0 #8 @ 14" O.C.
140 O.C., CUT BEND #5 @ 14" O.C. STAGGERED,
CUT #8 AT BREAKOUT LIMIT,
CUT & BEND #5
4" R.
6.5" 361,
6.5" LONGITUDINAL BARS:
#4 @ 13" O.C., CUT 1130.4 INV.
2" CLR,
& BEND rl)
LONGITUDINAL BARS: ZS- TYP. 1130-39 INV.
#4 @ 13" O.C., CUT
& BEND -------
VERTICAL BARS: #5 @
S=QN A --A 14' O.C., CUT & BEND VERTICAL BARS: #8 0 7"
O.C., CUT AT BREAKOUT
LIMIT
JUNCTION STRUCTURE DETAIL
N.T.S.
NOTES: ALL CONCRETE TO BE 4,000 PSI AND CONFORM TO SECTION 90
OF THE LATEST CALTRANS STANDARD SPECIFICATIONS.
VICINITY MAP
NOT TO SCALE
UNAUTINORIZ'ED CHANGES AND USES
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR,
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
NOTESa
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE
CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST OF
THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE
CITY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT
SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLE) DESIGN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL,
I
PRIVATE ENGINEERFS NOTICE to CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO
THESE PLANS SHALL CONDUCT THEIR OPERATIONS 50 THAT ALL EMPLOYEES ARE PROVIDED A SAFE
PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS
SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S.
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
RELATIONS' CONSTRUCTION SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANY WAY FOR THE CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS"
OF THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL RELATIONS' 'CONSTRUCTION SAFETY ORDERS".
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR
ENGINEER.
SHEET INDEX
SHT NO, DESCRIPTION
1 TITLE SHEET
2 STORM DRAIN IMPROVEMENT PLAN,
[PLAN A [PROFOLE
STORM 13RADN PLAN
HICKORY AVENTUT
DRC2016-00466
: :3
APPROVED By
REV DESCRIPTION CITY DATE V12111MI-1 D DATE APPROVED
CITY ENGINEER R.C.E. NO. L02SI44
JAL TWO WORKING 13ENCH MARK DESIGN
BEFORE DAYS BEFORE
YOU DIG YOU Din CITY OF RANCHO CUCAMONGA BENCH MARK NUMBER 0 DLW RECOMMENDED
018, 2
TOLL FREE BRASS IN TOP OF EAST END OF SOUTH CONCRETE E DRAWN
ND H-Z STAFF
1-800-227-2600 FEET ARCH CULVERT STAMPED "SECS 13M No.: 700 WALL OF 2 NO. 67512 Fk4litt-Zollars, Imo. Ont
-26 1968" SOUTH RATION 3990 CONCOURS 6 SUITE 3�O• ONTARIO, CALIFORNIA 764 SHEET
OF ATCHISON, TOPEKA AND SANTA FE RAILROAD, 0.12 MILES WEST CHECKED PHONE (909) 941-7799 FAX (809) 941-77,99
OF ROCHESTER, 8.5 FEET SOUTH OF SOUTH RAIL. CIVIL 1 OF
im
ELEVATION .... .1119.706 (NGVD29) OF PROJECT 306155.01 NO DRAWING 4 T-7
ININ M RAD 400
1
C.E. NO 1:17:151 )rp A /in vl9