HomeMy WebLinkAbout2479-DGENERAL NOTES
1 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THESE PLANS, THE CITY OF
RANCHO CUCAMONGA STANDARDS AND THE STANDARD SPECIFICATIONS FOR
PUBLIC WORKS CONSTRUCTION CURRENT EDITION, INCLUDING ITS ANNUAL
SUPPLEMENTS AND AMENDMENTS. CONTRACTOR SHALL BE FAMILIAR WITH
AND SHALL BE RESPONSIBLE FOR ADHERENCE TO THESE STANDARDS AND
SPECIFICATIONS.
2. ALL PIPELINES OR SUBSTRUCTURES OF ANY KIND, TELEPHONE OR POWER
POLES, WATER. METERS, VALVES, FIRE HYDRANTS, ETC., SHOWN OR NOT
SHOWN ON THESE PLANS WITHIN THE RIGHT-OF-WAY LIMITS OR IN ADJACENT
AREAS WHERE IMPROVEMENT WORK IS TO BE DONE SHALL BE REMOVED,
REPLACED, RELOCATED OR PROTECTED IN PLACE AS REQUIRED AT NO COST
TO THE CITY OF RANCHO CUCAMONGA.
3. ANY CONTRACTOR PERFORMING WORK ON THIS PROJECT SHALL FAMILIARIZE
HIMSELF WITH THE SITE AND SHALL BE SOLELY RESPONSIBLE FOR ANY
DAMAGE TO EXISTING FACILITIES RESULTING DIRECTLY OR INDIRECTLY FROM
HIS OPERATIONS, WHETHER OR NOT SUCH FACILITIES ARE SHOWN ON THE
PLANS.
4. A PERMIT SHALL BE OBTAINED FROM THE CITY OF RANCHO CUCAMONGA
PUBLIC WORKS ENGINEERING DEPARTMENT PRIOR TO ANY ENCROACHMENT OR
CONSTRUCTION WITHIN ANY CITY OF RANCHO CUCAMONGA EASEMENT OR
RIGHT-OF-WAY.'
5. ALL GRADE STAKES SHALL BE SET BY THE CONTRACTOR OR ENGINEER.
PAVING STAKES SHALL BE SET AT ALL HINGE POINTS, EDGE OF PAVEMENT
POINTS WITHIN 0.01 FOOT OF SUBGRADE ELEVATION AND AT NOT MORE THAN
50 FOOT INTERVALS. ADDITIONAL PAVING STAKES MAY BE REQUIRED BY
CITY ENGINEER, AS NEEDED, AT WARPED OR VERTICAL CURVE AREAS.
6. ALL SEWER, WATER, ELECTRIC, GAS, PHONE OR OTHER UTILITY LATERALS,
MAINS, OR CROSSINGS SHALL BE CONSTRUCTED PRIOR TO PAVING.
7. COMPACTION TESTS OF EMBANKMENT CONSTRUCTION, TRENCH BACKFILL
COMPACTING ORIGINAL GROUND AND ALL SUBGRADES SHALL BE PERFORMED
AT NO COST TO THE CITY OF RANCHO CUCAMONGA. A WRITTEN REPORT
WITH THESE COMPACTION TESTS SHALL BE SUBMITTED TO THE CITY ENGINEER
FOR APPROVAL. PRIOR TO THE PLACEMENT OF BASE MATERIALS AND/OR
SURFACING.
8. AT THE COMPLETION OF PAVING, A MATERIALS REPORT SHALL BE SUBMITTED
TO THE CITY ENGINEER, LISTING ALL TESTS OR DETERMINATIONS COMPLETED
TO VERIFY STABILITY, OIL CONTENT AND GRADATION OF ASPHALT PAVING.
9. PRIOR TO INSTALLATION OF ANY PAVING, A MATERIALS REPORT SHALL BE
SUBMITTED TO THE CITY ENGINEER, LISTING ALL TESTS OR DETERMINATIONS
COMPLETED TO VERIFY: R-VALUE, SIEVE ANALYSIS AND SAND EQUIVALENT
OF AGGREGATE BASE.
10. PAVING SHALL BE PERFORMED IN ACCORDANCE WITH R-VALUE AND
PAVEMENT TESTS TAKEN TO DETERMINE STRUCTURAL SECTIONS.
11. WHEN IMPROVEMENTS ARE TO BE PLACED ON NATIVE SOIL, WHICH CONSISTS
OF A ROCKY MATERIAL, THE SUBGRADE SHALL BE PREPARED BY REMOVING
ALL ROCKS WHICH PROTRUDE ABOVE THE SUBGRADE, AND ALL VOIDS OR
DEPRESSIONS SHALL BE FILLED WITH A FINE GRADE MATERIAL OF A QUALITY
BETTER THAN THE NATIVE MATERIAL.
12. IF THE ASPHALT CONCRETE IS TO BE PLACED ON SUBGRADE, A SOILS
STERILANT REGISTERED BY THE E.P.A. FOR USE UNDER A.C. AND P.C.C.
SHALL BE UNIFORMLY APPLIED AT THE MANUFACTURER'S RECOMMENDED RATE
FOR THE FULL PAVEMENT WIDTH PRIOR TO PAVING.
13. ESTIMATE OF QUANTITIES IS PROVIDED BY THE ENGINEER ONLY FOR THE
CONVENIENCE OF THE DEVELOPER. THE CONTRACTOR SHALL MAKE HIS OWN
DETERMINATION OF CONSTRUCTION QUANTITIES BEFORE SUBMITTING A BID.
ANY ITEM OF WORK REQUIRED BY THESE PLANS WHICH IS NOT SPECIFICALLY
LISTED IN THE ESTIMATE OF QUANTITIES SHALL BE CONSIDERED AS INCLUDED
IN THE OTHER ITEMS OF WORK.
14. STREET SIGNS, PER CITY OF RANCHO CUCAMONGA STANDARD NUMBER 401
SHALL BE CONSTRUCTED AT EACH INTERSECTION.
15. CITY APPROVAL OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM
RESPONSIBILITY FOR THE CORRECTION OF ERROR AND OMISSION DISCOVERED
DURING CONSTRUCTION. UPON. REQUEST, THE REQUIRED PLAN REVISIONS
SHALL BE PROMPTLY SUBMITTED TO THE CITY ENGINEER FOR APPROVAL.
16. WORK SITE AND EXTERIOR STREETS SHALL BE KEPT IN A NEAT, CLEAN,
HAZARD FREE, ORDERLY STATE, THROUGHOUT CONSTRUCTION. SITE SHALL BE
CLEANED UPON REQUEST OF THE INSPECTOR.
17. CONTACT ALL UTILITY COMPANIES, AS REQUIRED, 48 HOURS PRIOR TO
EXCAVATION.
18. ALL STRUCTURAL CONCRETE TO BE USED WITHIN SAN BERNARDINO FLOOD
CONTROL DAY, CREEK CHANNEL RIGHT-OF-WAY SHALL BE 4,000 PSI WITH
"A" GRADATION IN ALL INVERTS AND 4,000 PSI WITH "B" GRADATION IN ALL
WALLS. CONCRETE FOR ROCK INLET AND OUTLET STRUCTURES, BOTTOM
CONTROL, SPLASH PADS AND OTHER PROPOSED STRUCTURES SHALL BE 560e
OR C3250,
NOTE.,
1 THE PROCEDURES AND THE SPECIFICATIONS OF ALL
CONSTRUCTION EQUIPMENT TO BE USED FOR THE
REMOVAL, PLACEMENT, AND COMPACTION OF SOIL AND
PAVEMENT OVER AND ADJACENT TO THE MWD
PIPELINE MUST BE SUBMITTED FOR MWD REVIEW AND
WRITTEN APPROVAL AT LEAST 30 DAYS PRIOR TO
THEIR USE. THE PROCEDURES MUST BE SUCH THAT
EXCESSIVE UNBALANCED LOADS ARE NOT IMPOSED ON
THE MWD PIPELINE, PLEASE NOTE THAT MWD CANNOT
ALLOW ANY PROCEDURES THAT COULD SUBJECT THE
MWD PIPE TO EXCESSIVE IMPACTS OR VIBRATORY
LOADS. NO VIBRATORY EQUIPMENT IN VIBRATORY
MODE MUST BE USED WITHIN 25 FEET OF THE
CENTERLINE OF THE MWD PIPELINE.
2. VEHICLES WITH A VARIABLE WHEEL CONFIGURATION
SUCH AS READY -MIX CONCRETE TRUCKS WITH
LIFTABLE OR ADJUSTABLE AUXILIARY AXLES MAY BE
OPERATED IN THEIR HIGHWAY LEGAL CONFIGURATION
WHEN THEY ARE WITHIN 20 FEET OF THE CENTERLINE
OF THE MWD PIPELINE.
3. WHEN THE COVER OVER METROPOLITAN'S PIPELINE IS
LESS THAN 4-FEET, METROPOLITAN'S PIPELINE
LOADING RESTRICTION MUST APPLY:
IF THE COVER IS BETWEEN 2 AND 4 FEET,
EQUIPMENT MUST BE RESTRICTED TO THAT WHICH
IMPOSES LOADS NO GREATER THAN THAT OF A
TRACK -TYPE TRACTOR WEIGHING A MAXIMUM OF
12,000 POUNDS.
WHEN THE COVER IS LESS THAN 2 FEET, ONLY
HAND EQUIPMENT MAY BE USED.
4. NOTIFY JESSE FRANCO OF OUR WATER SYSTEM
OPERATIONS GROUP, TELEPHONE (9,09) 392-7184, AT
LEAST TWO WORKING DAYS PRIOR TO STARTING ANY
WORK IN THE VICINITY OF MWD FACILITIES.
5. MWD OPERATIONS MAINTENANCE BRANCH NEEDS TO
BE NOTIFIED TWO WORKING DAYS PRIOR TO STARTING
ANY WORK IN THE VICINITY OF THEIR EASEMENT.
mp__ I I IIIII
�j
I W-0
CONSTRUCTION NOTES
THE QUANTITIES SHOWN HEREON ARE ESTIMATES ONLY. THE CONTRACTORS SHALL PREPARE
THEIR OWN QUANTITIES AND BID A COMPLETE JOB.
A. CONTRACTOR TO ADJUST ALL VALVE COVERS AND MANHOLE RIMS TO GRADE
AFTER FINAL PAVING HAS BEEN INSTALLED.
INSTALL 18- RCP (D-LOAD AND PROFILE AS SHOWN ON PLANS) ......................................................
138
LF
INSTALL 72- RCP (0-LOAD AND PROFILE AS SHOWN ON PLANS)............. .............. ...........................
553
LF
048)
CONSTRUCT 36" CMP INLET PER DETAIL ON SHEET 2_ .... -------- ........................ ------
-------- 2
EA
( P49
WRAP STORM DRAIN PIPE WITH PPL-24 IMPERMEABLE POLYETHYLENE LINER
BY BTL INC, PROVIDE 24" OVERLAP AT SEAMS, SECURE LINER AROUND PIPE
WITH STRAPS AT 5' O.0 ........................... ........................... ............ ......................
40
LF
(65)
CONSTRUCT CURB OPENING CATCH BASIN PER CITY OF RANCHO CUCAMONGA STD. 300, W=3.5 ...............
2
EA
CONSTRUCT MANHOLE NO. 2 PER CITY OF RANCHO CUCAMONGA STD. 319 ....................... .................
3
EA
CONSTRUCT JUNCTION STRUCTURE NO. 4 PER CITY OF RANCHO CUCAMONGA STD. 333, CASE 1 ..............
2
EA
CONSTRUCT CONCRETE COLLAR PER SPPWC STD. PLAN 380-4 ............ ..................................
.... 1
EA
REMOVE EXISTING DEBRIS RACK CAGE AND JOIN EXISTING STORM DRAIN ............................................
1
EA
099
CONSTRUCT 24" PCC CAST -IN -PLACE PROTECTIVE SLAB PER DETAIL ON SHEET 3 ............................
2,652
SF
L69�1
INSTALL 6" RIGID CELLULAR POLYSTYRENE THERMAL INSULATION PER ASTM C-578-95. __ .................
1,836
SF
(0126)
ADJUST MANHOLE RIM TO GRADE AFTER FINAL SURFACE HAS BEEN INSTALLED ...................................
3
EA
_j(BNSF)_�(METROLINK)
T-
PROPOSED qEVELOPMENT
------------
J___L__i --- i --- L-1 --- t --- L__J --- I --- 1__J ---
<
Y -tr,^ I -
-- — — — — — — — — — — — — —
SHEETINDEX
SHT NO.
DESCRIPTION
1
TITLE SHEET
2
STORM DRAIN IMPROVEMENT PLAN
3
PROTECTIVE SLAB DETAILS
LEGEND
EXISTING R/W
PROPOSED R/W
— — — —
LOT LINE
CENTER LINE
FIRE HYDRANT
.........
PROPERTY LINE
R/W----------
RIGHT OF WAY
C . .......
CENTERLINE
SOT. . ....
BOTTOM
SO . __
STORM DRAIN
SMH .........
SEWER MANHOLE
STD ........
STANDARD
SEW .........
SEWER
TYP ...........
TYPICAL
IMP. . . .....
IMPROVEMENT
PA.P .. ........
PROTECT IN PLACE
DWG .........
DRAWING
EXIST..........
EXISTING
RW ..........
RECYCLED WATER
INV ...... _
. INVERT OF PIPE
UT .........
UTILITY
CVWD .........
CUCAMONGA VALLEY
WATER DISTRICT
SPPWC ---------
STANDARD PLANS FOR
PUBLIC WORKS CONSTRUCTION
PROPOSED STORM DRAIN
EXISTING SEWER
EXISTING WATER
EXISTING RECYCLED WATER
EXISTING STORM DRAIN
EXISTING GAS
EXISTING TELEPHONE
EXISTING ELECTRICAL
EASEMENT
CITY OF RANCHO CUCAMONGA BENCH MARK NO. 10016
NGVD29, ELEVATION =1 128.056'
FD. 2" BRASS DISK STAMPED, "SECS BM NO, 700-25 1968" IN SOUTH
END OF THE WEST CONCRETE BRIDGE ABUTMENT OF A STEEL GIRDER
BRIDGE ACROSS THE ETIWANDA FLOOD CONTROL CHANNEL, 0.2 MILES
EAST OF 15 FREEWAY, 8' SOUTH OF THE SOUTH RAIL.
VICINITY MAP
NOT TO SCALE
CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR,
OR LIABLE FOR, UNAUTHORIZED CHANGES TO OR USES OF THESE PLANS.
NOTESm
CITY ACCEPTANCE OF PLANS DOES NOT RELIEVE THE DEVELOPER FROM RESPONSIBILITY FOR THE
CORRECTION OF ERRORS AND OMISSIONS DISCOVERED DURING CONSTRUCTION. UPON REQUEST OF
THE CITY INSPECTOR, THE REQUIRED PLAN REVISIONS SHALL BE PROMPTLY SUBMITTED TO THE
CITY ENGINEER FOR REVIEW.
CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED
CONSTRUCTION PRACTICES CONSTRUCTION CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND
COMPLETE RESPONSIBILITY FOR JOB SITE CONDMONS DURING THE COURSE OF CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT
SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND
CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD DESIGN
PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH
THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE
NEGLIGENCE OF DESIGN PROFESSIONAL.
PRIVATE ENGINEER'S NOTICE TO CONTRACTORS
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON
THESE PLANS ARE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. TO THE BEST OF OUR
KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE PLANS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES
SHOWN AND ANY OTHER LINES OR STRUCTURES NOT SHOWN ON THESE PLANS.
ALL CONTRACTORS AND SUBCONTRACTORS PERFORMING WORK SHOWN ON OR RELATED TO
THESE PLANS SHALL CONDUCT THEIR OPERATIONS SO THAT ALL EMPLOYEES ARE PROVIDED A SAFE
PLACE TO WORK AND THE PUBLIC IS PROTECTED. ALL CONTRACTORS AND SUBCONTRACTORS
SHALL COMPLY WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS" OF THE U.S.
DEPARTMENT OF LABOR, AND WITH THE STATE OF CALIFORNIA DEPARTMENT OF INDUSTRIAL
RELATIONS' "CONSTRUCTION SAFETY ORDERS".
THE CIVIL ENGINEER SHALL NOT BE RESPONSIBLE IN ANYWAY FOR THE CONTRACTORS' AND
SUBCONTRACTORS' COMPLIANCE WITH THE "OCCUPATIONAL SAFETY AND HEALTH REGULATIONS"
OF THE U.S. DEPARTMENT OF LABOR OR WITH THE STATE OF CALIFORNIA DEPARTMENT OF
INDUSTRIAL RELATIONS' "CONSTRUCTION SAFETY ORDERS".
CONTRACTOR FURTHER AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT,
INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL. APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; , AND THAT THE CONTRACTOR
SHALL DEFEND, INDEMNIFY AND HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND
ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS
PROJECT, EXCEPTING FOR ANY LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE OWNER OR
ENGINEER.
[PLAN A PROFILE
37anim DRAW PLAN
TIM SHEET
SANTA ANITA AVENUE
DATE CITY APPROVED By
APPROVED CITY ENGINEEF
DESIGN
DLW
ti46
DRAWN
kNO. 7 '512 H-Z STAFF
RAM CHECKED
_30�_2019 "I I
DATE I " I 112
R.C.E. NO. 67514
-7wI IF T A rN RECOMMENDED
3990 CONCOURS I SUITE 330 ONTARIO, CALIFORNIA 91764
PHONE (909) 941-7799 FAX (909) 941-7789 1 OF 3
lb DRAWING NO.
JOHN MURAD 40 A4
4- 1 .11 ff .1-1- 2479-D
—x 1-4 1 4—
X R.
C'4
41 18 43 44 Di T"4�,5
J�
n A on o7'
x w
"1 0-
CC3INSTRUCTION NOTE
INSTALL 18- RCP (D—LOAD AND PROFILE AS SHOWN ON PLANS)
Dts INSTALL 72- RCP (D—LOAD AND PROFILE AS SHOWN ON PLANS)
D 48 CONSTRUCT 36" CUP INLET PER DETAIL ON SHEET 2
D04 9 WRAP STORM DRAIN PIPE WITH PPL-24 IMPERMEABLE POLYETHYLENE LINER
BY BTL INC, PROVIDE 24" OVERLAP AT SEAMS, SECURE LINER AROUND PIPE
WITH STRAPS AT 5' O.C.
@) CONSTRUCT CURB OPENING CATCH BASIN PER CITY OF RANCHO CUCAMONGA STD. 300, W=3.5'
CONSTRUCT MANHOLE NO. 2 PEP CITY OF RANCHO CUCAMONGA STD. 319
Dst CONSTRUCT JUNCTION STRUCTURE NO. 4 PER CITY OF RANCHO CUCAMONGA STD. 333, CASE I
Dsa CONSTRUCT CONCRETE COLLAR PER SPPWC STD. PLAN 380-4
Dst REMOVE EXISTING DEBRIS RACK CAGE AND JOIN EXISTING STORM DRAIN
E8 CONSTRUCT 24" PCC CAST —IN —PLACE PROTECTIVE SLAB PER DETAIL ON SHEET 3
(R INSTALL 6" RIGID CELLULAR POLYSTYRENE THERMAL INSULATION PER ASTM C-578-95
D1026 ADJUST MANHOLE RIM TO GRADE AFTER FINAL SURFACE HAS BEEN INSTALLED
LATERAL D PROP. EASEMENT
�RT
In
D98
C>
co
39 x2!
+
40'
dO7 U-)
I
V) 1104.00 TG z +
D48 co
110too INV.
-
MWD
6�7)
DAYS BEFORE
V, EM
S C E RIGHT —OF'- , WA'
EXIST, 12" 01 NO'
C)
00 C)
r- 0
C> CD C4
CD a
�LO �? �
— cn � u �
Q C)
� ui
cy CD
'o t
to
rnT C'4
C-4 'It
+
+
+v
00
+
CATCH
BASIN al
CATC
SCALE 1"=10'
STATIONS PER STREET IMPROVEMENT PLANS
STATIONS
PER
17"
r7'
0
2 MWD
4E, SEE MWD
f SHEET 1
TION FROM SOUTHERN CALIFORNIA EDISON
`SCE) AND METROPOLITAN WATER DISTRICT (MIND)
D TO WORK WITHIN THEIR RIGHT—OF—WAY.
""I
to
to
ui
VEMENT PLANS
MWD NOTE:
MWD REVIEW AND APPROVAL REQUIRED
PRIOR TO ANY CONSTRUCTION WITHIN
MWD EASEMENT.
SCALE- ,,
40,
(IN FEET)
1"=40'
NOTE:
HORIZONTAL AND VERTICAL LOCATIONS TO
BE VERIFIED IN THE FIELD AND ENGINEER
NOTIFIED OF ANY DISCREPANCIES PRIOR TO
CONSTRUCTION.
CITY OF RANCHO CUCAMONGA BENCH MARK NO. 10016
NOVD29, ELEVATION=1128.056'
FD, 2" BRASS DISK STAMPED, "SBCS BM NO. 700-25 1968" IN SOUTH
END OF THE WEST CONCRETE BRIDGE ABUTMENT OF A STEEL GIRDER
BRIDGE ACROSS THE ETIWANDA FLOOD CONTROL CHANNEL, 0.2 MILES
EAST OF 15 FREEWAY, 8' SOUTH OF THE SOUTH RAIL.
#4REBAR SEE PLAN & PROFILE FOR D2
@ 6" 0. C. AND ELEVATIONS A & B
D 'l"-
E h D
WELDED (TYP.) Dl=1.5xD2 (OR AS SHOWN)
LEV �"B" D2=D3
FINISHED GRADE
REMOVABLE STD. GALV.
x
D, CMP CONN, BAND
1
4 GA CMI:'MUM
�� 8" MIN.
ELEV. "A
cmp RCP
CONC. COLLAR
CONC. SLAB SLOPE TO DRAIN WHERE APPLICABLE
SLOPE TO DRAIN
2' OR AS INDICATED
ON PLANS
�CMP
D48 TO�INLET
LET
S
NOT TO SCAL7
370RH MAN PLAH
IA
SANTA ANITA AVENUEcn
STA. 24+90.96 TO STA. 30+64.65
ROW 2017—
APPROVED
BY DATE
<
CITY
DATE APPROVED
CITY ENGINEER
R.C.E. No.
67514
Ill
DESIGN
OLIN
RECOMMENDED
f—UFq—Z0UAPS
I
Sq
DRAWN
/12-y-
-
8�
0. 6 5 2
H—Z STAFF
Huitt-Zollars, Inc. Ontario
SHEET
CHECKED
T 3990 CONCOURS - SUI 5 E 330 ONTARIO, CALIFORNIA 91764
PHONE (909) 941-7799 FAX (909) 941-7789 2
OF 3
lk � -3 219
im
-
PROJECT NO
DRAWING No.
0
S.
-in940.cs nl'
OHNNY PURAD.
2479—D
48"
24"
SYMMETRICAL
ABOUT CL
FINISHED SURFACE
#6 @ 12" 6 PROTECTION SLAB
RIGID CELLULAR POLYSTYRENE
2" CLEAR THERMAL INSULATION PER ASTM C-578-95
11a9:a0 Fs
13.5' 6'
3" CLEAR '-#10 a 6"
39'
i COMPACT UPPER --I
12" OF BEARING /
\ AREA TO 95%
i MAXIMUM DENSITY y
1
P. C.P
WIND PIPEUIVF � '
j
t NOTES:
1. F'c = 4,000 PSI AT 28 DAYS
f 2. Fy = 60,000 PSI
3. BACKFILL SHALL BE NON -EXPANSIVE AND
COMPACTED TO 95% OF STANDARD AASHTO
\ f MAXIMUM DRY UNIT WEIGHT
PCC SLASDETAIL
NOT TO SCALE
39 L
54 59.63
RT. I
-- 40' MWD EASEMENT
!
PCC SLAB
i
LAYOUT
2" WATER
8" SEWER
72" STORM DRAIN
II Wfi N & IROF1LE
�r�Rnn �r�aiM �LA�
KUV4 zu I /
APPROVED BY
DATE APPROVED CITY ENGINEER
DATE -71 ®! l� b
R.C.E. N0. 67514
DAYS BEFORE
CITY OF RANCHO CUCAMONGA BENCH MARK NO. 10016
NGVD29, ELEVATION =11 28.056'
FD. 2" BRASS DISK STAMPED, "SBCS BM NO. 700-25 1968" IN SOUTH'
END OF THE WEST CONCRETE BRIDGE ABUTMENT OF A STEEL GIRDER
BRIDGE ACROSS THE ETIWANDA FLOOD CONTROL CHANNEL 0.2 MILES
EAST OF 15 FREEWAY, 8' SOUTH OF THE SOUTH RAIL.
NO67512 U
EXPIRATION CLHEQKC
CRE
5 30-2019
3990
SUfTF 3M
31 941-7�9Q
AUFORNIA 91764
941-7769
c-71
ai
7OF
DRAWING N0.
2479-D