HomeMy WebLinkAbout2021-01-05 Agenda Packet
Design Review Committee Meeting
AGENDA
January 5, 2021
Rancho Cucamonga, CA 91730
7:00 p.m.
PURSUANT TO GOVERNOR GAVIN NEWSOM’S EXECUTIVE ORDER N-29-20 THIS MEETING WILL
BE HELD AS A TELECONFERENCE MEETING
In response to the Governor's Executive Orders, the San Bernardino County Department of Public
Health requirements, and to ensure the health and safety of our residents by limiting contact that could
spread the COVID–19 virus, there will be no members of the public in attendance at the Design Review
Committee meetings. Members of the Design Review Committee and staff will participate in this meeting
via teleconference.
In place of in-person attendance, members of the public can observe and offer comment at this
meeting via Zoom:
VIEW MEETING VIA ZOOM APP OR ZOOM.COM AT:
zoom.us/join
using Webinar ID: 962 4174 3925
-or-
YOU CAN DIAL-IN USING YOUR PHONE
UNITED STATES: + 1 (669) 900-6833
Access Code: 962 4174 3925
IMPORTANT NOTICE REGARDING JANUARY 5, 2021, DESIGN REVIEW COMMITTEE MEETING
As an alternative to participating in the teleconference, you may submit comments in writing to
Elizabeth.Thornhill@CityofRC.us by 12:00pm on the date of the meeting. Written comments will be
distributed to the Committee and read into the record.
A. Call to Order
B. Public Communications
C. Consent Calendar
C1. Consideration to adopt Regular Meeting Minutes of November 10, 2020. (No meetings
November 17, 2020, December 1, 2020 and December 15, 2020.)
D. Project Review Items
D1. DESIGN REVIEW DRC2019-00371 (LOCATED ON A VACANT PARCEL ADDRESSED 8281
UTICA AVENUE) – BLUE ENGINEERING & CONSULTING, INC. - A request for site plan and
architectural review of an industrial building totaling 13,116 square feet on 0.72 acres of land
located on a vacant parcel addressed 8281 Utica Avenue in the Industrial Park (IP) District;
APN: 0208-062-10. This item is exempt from the requirements of the California Environmental
Quality Act (CEQA) and the City’s CEQA guidelines under CEQA Section 15332 – In-Fill
Development Projects.
Design Review Committee Regular Meeting Agenda – January 5, 2021
Page 2 of 2
If you need special assistance or accommodations to participate in this meeting, please
contact the Planning Department at (909) 477-2750. Notification of 48 hours prior to the
meeting will enable the City to make reasonable arrangements to ensure accessibility.
Listening devices are available for the hearing impaired.
E. Adjournment
The Design Review Committee has adopted Administrative Regulations that set an 11:00 p.m. adjournment
time. If items go beyond that time, they shall be heard only with the consent of the Committee.
I, Elizabeth Thornhill, Executive Assistant of the City of Rancho Cucamonga, or my designee,
hereby certify that a true, accurate copy of the foregoing agenda was posted on Wednesday,
December 23, 2020, seventy-two (72) hours prior to the meeting per Government Code
54954.2 at 10500 Civic Center Drive, Rancho Cucamonga, California and on the City’s website.
Design Review Committee
Special Meeting Agenda
November 10, 2020
MINUTES
Rancho Cucamonga, CA 91730
7:00 p.m.
A. Call to Order
The meeting of the Design Review Committee was held on November 10, 2020. The meeting was called
to order by Mike Smith at 7:00pm.
Design Review Committee present: Francisco Oaxaca, Diane Williams, Mike Smith.
Staff Present: Vincent Acuna, Associate Planner; David Eoff, Senior Planner; Dat Tran, Assistant
Planner.
B. Public Communications
Mike Smith opened the public communication and hearing no comment, closed public communications.
C. Consent Calendar
C1. Consideration to adopt Regular Meeting Minutes of March 17, 2020.
C2. Consideration to adopt Regular Meeting Minutes of June 16, 2020.
Motion by Williams, second by Oaxaca. Motion carried 3-0 to adopt the March 17, 2020 and June 16,
2020 minutes as presented.
D. Project Review Items
D1. DESIGN REVIEW DRC2019-00651 (LOCATED IN THE GENERAL INDUSTRIAL (GI) ZONE
AT 12550 ARROW ROUTE) – SGE CONSULTING STRUCTURAL ENGINEERS FOR AIR
GAS SPECIALTY GAS FACILITY - A request to demolish an existing office building and
construct a new 18,165 square-foot industrial building/production facility with a 3,490 square-
foot office and additional site improvements - APN: 0229-031-23. This item is exempt from the
requirements of the California Environmental Quality Act (CEQA) and the City’s CEQA
guidelines under CEQA Section 15332 – In-Fill Development Projects.
Staff provided a brief presentation of the project. The Committee generally liked the project and agreed that
the fencing material along the perimeter should be enhanced with something that complements the new
building better. The Committee recommended approval of the project to the Planning Commission and
instructed the applicant to work with staff to revise the perimeter fencing to a different material such as
wrought iron, or explore other options along the perimeter
The Committee took the following action:
Recommend approve to PC/PD.
Design Review Committee Special Meeting Minutes – November 10, 2020
Page 2 of 2
Draft
D2. DESIGN REVIEW DRC2019-00985 (LOCATED AT 10006 FOOTHILL BOULEVARD) –
TUCKER SCHOEMAN VENTURE FOR KEN’S JAPANESE RESTAURANT - A request to
construct a 3,358 square-foot single-story restaurant (Ken's Japanese Restaurant) to replace
an existing 2,822 square-foot restaurant building within the Commercial Office (CO) District,
APN: 1077-621-26 and -027. This item is exempt from the requirements of the California
Environmental Quality Act (CEQA) and the City’s CEQA guidelines under CEQA Section 15303
– New Construction or Conversation of Small Structures.
Staff made a brief presentation about the project. Mike Smith said he likes the modern architecture. Francisco
Oaxaca and Diane Williams agreed, noting that the project will be a significant improvement not only on the
project site, but along the Foothill corridor as well.
Diane Williams expressed concern about parking lot lighting spilling into the residential neighborhood to the
north. Staff noted that all projects are conditioned to ensure that no light spillage occurs into residential
properties, per the Development Code, and that staff will pay special attention to the photometric plan during
building plan check.
Design Review Committee recommended DRC2019-00985 move forward to Planning Commission. The
committee liked the modern architecture and the garden frontage between the restaurant and Foothill of the
proposed building.
The Committee took the following action:
Recommend approve to PC/PD.
E. Adjournment
Meeting was adjourned at 7:50pm.
Respectfully submitted,
________________________
Elizabeth Thornhill
Executive Assistant, Planning Department
Approved:
DESIGN REVIEW COMMENTS
7:00 p.m. Sean McPherson January 5, 2021
DESIGN REVIEW DRC2019-00371 – BLUE ENGINEERING & CONSULTING, INC. - A request
for site plan and architectural review of an industrial building totaling 13,116 square feet on 0.72
acres of land located on a vacant parcel addressed 8281 Utica Avenue in the Industrial Park (IP)
District; APN: 0208-062-10. This item is exempt from the requirements of the California
Environmental Quality Act (CEQA) and the City’s CEQA guidelines under CEQA Section 15332
– In-Fill Development Projects.
Site Description: The project site consists of one vacant lot located within the Industrial Park (IP)
District, on property addressed 8281 Utica Avenue. The site is generally flat and at-grade with
Utica Avenue. The project site’s street frontage along Utica Avenue is improved with curb and
gutter, but not with sidewalks or streetlights.
The existing Land Use, General Plan and Zoning designations for the project site and adjacent
properties are as follows:
Table A: General Plan and Zoning Designations
Land Use General Plan Zoning
Site Vacant Industrial Park Industrial Park (IP) District
North Office Industrial Park Industrial Park (IP) District
South Office Industrial Park Industrial Park (IP) District
West Office Industrial Park Industrial Park (IP) District
East Office Industrial Park Industrial Park (IP) District
Project Overview: The applicant. Blue Engineering & Consulting proposes to develop a 13,116
square foot two-story office building on 31,233 (0.72) acres of land located on a vacant parcel
addressed 8281 Utica Avenue in the Industrial Park (IP) District. The applicant states that the
proposed building will be used as an office building for professional services (i.e. lawyers,
engineers, mortgage brokers, and architects), and is divisible into separate suites.
The north/northwest (front) elevation of the office building will face Utica Avenue. Vehicular
access to the project will be from a shared driveway off Utica Avenue leading to an on-site parking
lot which will be located in between the street and the proposed building. Additional access to
the parking lot will be provided from an adjacent parcel via another shared access driveway to
the south. The floorplan includes a lobby with an elevator and two conference rooms, plus offices
and restrooms on the ground floor. A vestibule, two more conference rooms, and additional
offices and restrooms are located on the second floor. Storage rooms and breakrooms are also
located on each floor.
The project complies with the City’s landscape standards. Site landscape coverage meets the
minimum requirement of 15% and includes an overall depth of 25 feet along Utica Avenue. The
landscaping palette includes a variety of trees, shrubs, and ground cover to help screen
mechanical equipment and enhance the appearance of the building.
DRC COMMENTS
DESIGN REVIEW DRC2019-00371 – BLUE ENGINEERING & CONSULTING, INC.
January 5, 2021
Page 2
The project complies with each of the related development standards for the Industrial Park (IP)
District as shown on Table B below:
Parking: Pursuant to Development Code Section 17.64.050, Table 17.64.050-1, parking for
offices is based on the ratio of 4 parking spaces for every 1,000 gross square feet. Development
Code Section 17.64.050.A.6 further provides that for commercial, office and industrial zoned
properties, square footage dedicated to office hallways 44 inches or less, electrical and
mechanical rooms, elevator shafts, stairwells, bathroom and storage closets may be deducted
from the gross square footage for parking stall calculation purposes. Thus, while the gross floor
area of the proposed project totals 13,116 square feet, approximately 2,196 square feet of the
proposed project includes those areas listed above that are exempt from parking calculations.
This translates into a parking requirement of 44 parking spaces for the project.
Table C below demonstrates that the project meets the minimum required number of parking
spaces:
Table C: Parking Compliance
Parking Ratio Required Parking Provided Parking
Offices
4 per 1,000 square feet (exclusive of
areas provided in Dev. Code Section
17.64.050.A.6)
44 spaces 44 spaces
Staff Comments: Staff supports the proposed building’s architecture and site layout, which will
complement the surrounding established professional office neighborhood. The building, which
proposes a contemporary vernacular theme, is well designed with architectural elements that
carry to each elevation (360 Degree Architecture). The primary entrance to the building is
surrounded by an angled aluminum storefront system projection which also protrudes from each
Table B: Compliance with Industrial park (IP) Development Standards
Development Standard Required Proposed Complies?
Building Height
Maximum 35 feet (at front
setback) and
75 feet (1-foot increment from the
setback line)
30 feet, 8
inches YES
Floor Area Ratio (FAR) 40-60%
41.9% (13,116
/ 31,233
square feet)
YES
Front Building Setback
(Utica Avenue) 25 feet ~87 feet YES
Average Depth of
Landscape 25 feet 26.2 feet YES
Parking Setback 15 feet (Utica Avenue) 19.64 YES
Interior Side Yard
Setback Min. 5 feet
37.2 (north
property line);
56 feet (south
property line)
YES
Rear Yard Setback Min. 0 feet 10 feet YES
Open Space/Landscape
Standards 15% 16.8% YES
DRC COMMENTS
DESIGN REVIEW DRC2019-00371 – BLUE ENGINEERING & CONSULTING, INC.
January 5, 2021
Page 3
facade of the building. The entrance is further accentuated by a two-story wood frame feature
comprised of Stonewood architectural panels (ESR-4154). Other attractive elements include an
aluminum canopy at the front entrance which is supported by pillars encased in Coronado Stone
veneer (Coronado Honey ledge – Sioux Falls). Both the aluminum canopy and stone veneer are
respectably carried out through each facade of the building. Public frontage improvements along
Utica Avenue will also be required to be completed, including a new parkway, sidewalk and
streetlights.
Major Issues: The following broad design issues will be the focus of Committee discussion
regarding this project.
1. None
Secondary Issues: Once all of the major issues have been addressed, and time permitting, the
Committee will discuss the following secondary design issues.
1. None
Policy Issues: The following items are a matter of Planning Commission policy and should be
incorporated into the project design without discussion.
1. None
Staff Recommendation:
Staff recommends that the project be forwarded to the Planning Commission as presented for
final review.
Design Review Committee Action:
Staff Planner: Sean McPherson, Senior Planner
Members Present:
Staff Coordinator: Mike Smith, Principal Planner
CLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING5FeetSCALE 1" = 20'4020010
5460 SFPROPOSED GROUNDFLOOR ARE A674 SFNON. PARK.161 SFNON. PARK.268 SFNON. PARK.3' - 8"3' - 8"5460 SFPROPOSED SECONDFLOOR674 SFNON. PARK.268 SFNON. PARK.152 SFNON. PARK.ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:22 PM1" = 20'-0"10/14/2020 2:01:22 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA0COVER SHEET20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGAAREA PLANNORTHSHEET INDEXA0 COVER SHEETA0.1 GENERAL NOTESA0.2 GENERAL NOTESA0.3 GENERAL NOTESA0.4 SYMBOLS & ABBREVIATIONSA1 SITE PLANA2 FIRST FLOORA2.1 SECOND FLOORA4 EXTERIOR ELEVATIONSA4.1 EXTERIOR ELEVATIONSA4.2 EXTERIOR ELEVATIONSA4.3 MATERIAL BOARDA4.4 WOOD SPECA4.6 STONE SPECA5 ROOF PLANA6 SECTIONSA7 3D VIEWSA7.1 RENDERINGSE1 ELECTRICAL PLANS1 STRUCTURAL PLANS2 DETAILSPROPOSED -2 STORY BUILDINGA. OWNER• NAME:KAMRAN AKBAR -ML MORTGAGE CORP• MAIL:• CONTACT NO:909-697-0585• EMAILKAMRAN@MLMORTGAGE.NETB. DESIGNER• NAME:EVERETT SMITHDESIGNS• CONTACT NO:(951 ) 323 2187 • EMAIL:EVERETT@EVERETTSMITHDESIGNS.COMC. CONTRACTOR• NAME:• ADDRESS:• CONTACT NO: • EMAILD. STRUCTURAL• NAME:• CONTACT NO:• EMAIL:E. ELECTRICAL• NAME:• CONTACT NO:• EMAIL:A. BUILDING INFO• USE TYPE:COMMERCIAL OFFICE BUILDING• OCCUPANCY:B• CONSTRUCT TYPE: I-AB. C. SITE INFO• LOT AREA:31,233• PARCEL # (APN):0208-062-10-0000• LEGAL DESCRIPTION:TRACT 12176 LOT 14 AND INT IN COM AREA• ZONE:COMMERCIALCONTRACTOR RESPONSIBILITY"CONTRACTOR RESPONSIBILITY" EACH CONTRACTOR OR SUB-CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF THE WIND AND /OR SEISMIC RESISTING SYSTEM THAT IS LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK REQUIRING SPECIAL INSPECTION. THE CONTRACTORS STATEMENT OF RESPONSIBILITY SHALL CONTAIN THE FOLLOWING1. ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS.2. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL.3. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE DISTRIBUTION OF REPORTS AND SCHEDULE4. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION"GENERAL NOTES1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO STARTING WORK, AND SHALL NOTIFY THE DESIGNER OF DISCREPANCIES OR INCONSISTENCIES.2. THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT REPRESENT THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TO, BRACING AND SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, CONSTRUCTION LOADS OF MATERIALS, ETC. THE CONTRACTOR, AT NO EXPENSE TO THE OWNER, SHALL RETAIN QUALIFIED PROFESSIONALS TO DETERMINE FIELD LAYOUT OF THE BUILDING ELEMENTS, AND THE ADEQUACY OF ALL PROPOSED BRACING AND SHORING.3. OBSERVATION VISITS TO THE SITE BY THE ENGINEER SHALL NOT INCLUDE OBSERVATION OF SAFETY METHODS, BRACING OR SUPPORT.4. PLAN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS.5. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND STANDARD DETAILS.6. CLARIFICATION SHALL BE REQUESTED FROM THE ENGINEER FOR ALL WORK INDICATED ON THE PLANS THAT IS NOT SPECIFICALLY DETAILED, AND IS NOT SIMILAR TO WORK THAT IS DETAILED.7. SEE EXISTING AND / OR OTHER PLANS FOR SIZE AND LOCATION OF ALL DOOR AND WINDOW OPENINGS, SIZE AND LOCATION OF ALL NON-BEARING PARTITIONS, SIZE AND LOCATION OF ALL CURBS, DRAINS, DEPRESSED AREAS, SLOPES AND ELEVATION CHANGES, CHAMFERS, GROOVES, INSERTS, ALL FINISHES, AND SIZE AND LOCATION OF ALL FLOOR AND ROOF OPENINGS.8. SEE OTHER PLANS FOR ALL WATERPROOFING REQUIREMENTS. THE ENGINEER IS NOT RESPONSIBLE FOR WATERPROOFING DETAILS AND SPECIFICATIONS.9. MECHANICAL, PLUMBING, AND ELECTRICAL REPAIRS SHALL BE UNDER SEPARATE PERMIT AND SHALL BE PERFORMED BY A LICENSED CONTRACTOR LICENSED IN THE APPROPRIATE FIELD.10. MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOORS OR ROOFS. LOADS SHALL NOT EXCEED DESIGN LOADING FOR SUPPORTING MEMBERS.11. UNLESS APPROVED BY THE LOCAL C.B.O. OR BUILDING DEPARTMENT (PER CPC SECTION 301.2.5.) PEX IS NOT AN APPROVED BUILDING MATERIAL.NPDES NOTESNOTES MUST BE SHOWN AS WORDED, ON THE TITLE SHEET OF THE PLAN.1. IN THE CASE OF EMERGENCY, CALL: • AT WORK PHONE #: • OR CELL PHONE #:2. SEDIMENT FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING STRUCTURAL CONTROLS TO THE MAXIMUM EXTENT PRACTICABLE.3. STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OR ADJACENT PROPERTIES VIA RUNOFF, VEHICLE TACKING, OR WIND.4. APPROPRIATE BMPS FOR CONSTRUCTION RELATED MATERIALS, WASTES, SPILLS SHALL BE IMPLEMENTED TO MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTIES BY WIND OR RUNOFF.5. RUNOFF FROM EQUIPMENT AND VEHICLE WASHING SHALL BE CONTAINED AT CONSTRUCTION SITE UNLESS TREATED TO REDUCE OR REMOVE SEDIMENT AND OTHER POLLUTANTS.6. ALL CONSTRUCTION CONTRACTOR AND SUBCONTRACTOR PERSONNEL ARE TO BE MADE AWARE OR THE REQUIRED BEST MANAGEMENT PRACTICES AND GOOD HOUSEKEEPING MEASURES FOR THE PROJECT SITE AND ANY ASSOCIATED CONSTRUCTION STAGING AREAS.7. AT THE END OF EACH DAY OF CONSTRUCTION ACTIVITY ALL CONSTRUCTION DEBRIS AND WASTE MATERIALS SHALL BE COLLECTED AND PROPERLY DISPOSED IN TRASH OR RECYCLE BINS.8. CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITE. DISCHARGES OF MATERIAL OTHER THAN STORM WATER ONLY WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR PARTS 117 AND 302.9. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC, RADIATOR OR BATTERY FLUIDS; FERTILIZERS, VEHICLE/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING AND SUPER CHLORINATED POTABLE WATER LINE FLUSHING. DURING CONSTRUCTION, PERMITTEE SHALL DISPOSE OF SUCH MATERIALS IN A SPECIFIED AND CONTROLLED TEMPORARY AREA ON SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORM WATER RUNOFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS.10. DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS VIA SURFACE EROSION IS PROHIBITED. DEWATERING OF NON CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD.11. GRADED AREAS ON THE PERMITTED AREA PERIMETER MUST DRAIN AWAY FROM THE FACE OF SLOPES AT THE CONCLUSION OF EACH WORKING DAY. DRAINAGE IS TO BE DIRECTED TOWARD DESILTING FACILITIES.12. THE PERMITTEE AND CONTRACTOR SHALL BE RESPONSIBLE AND SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT PUBLIC TRESPASS ONTO AREAS WHERE IMPOUNDED WATER CREATES A HAZARDOUS CONDITION.13. THE PERMITTEE AND CONTRACTOR SHALL INSPECT THE EROSION CONTROL WORK AND INSURE THAT THE WORK IS IN ACCORDANCE WITH THE APPROVED PLANS.14. THE PERMITTEE SHALL NOTIFY ALL GENERAL CONTRACTORS, SUBCONTRACTORS, MATERIAL SUPPLIERS, LESSEES, AND PROPERTY OWNERS: THAT DUMPING OF CHEMICALS INTO THE STORM DRAIN SYSTEM OR THE WATERSHED IS PROHIBITED.15. EQUIPMENT AND WORKERS FOR EMERGENCY WORK SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON. NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY DEVICES WHEN RAIN IS IMMINENT.16. ALL REMOVABLE EROSION PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHEN THE 5 DAY RAIN PROBABILITY FORECAST EXCEEDS 40%.17. SEDIMENTS FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING AN EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROLS TO THE MAXIMUM EXTENT PRACTICABLE, AND STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OR ADJACENT PROPERTIES VIA RUNOFF, VEHICLE TRACKING, OR WIND.18. APPROPRIATE BMPS FOR CONSTRUCTION RELATED MATERIALS, WASTES, SPILLS OR RESIDUES SHALL BE IMPLEMENTED AND RETAINED ON SITE TO MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTY BY WIND OR RUNOFF.APPLICABLE STANDARDS• 2019 CALIFORNIA RESIDENTIAL CODE (CRC) • 2019 CALIFORNIA BUILDING CODE (CBC)• 2019 CALIFORNIA PLUMBING CODE (CPC) • 2019 CALIFORNIA ELECTRICAL CODE (CEC)• 2019 CALIFORNIA MECHANICAL CODE (CMC) • 2019 CALIFORNIA GREEN BUILDINGPROJECT DIRECTORYPROJECT INFORMATIONTHE SITESQUARE FOOTAGE & LOT COVERAGESCOPE OF WORKA. SCOPE OF WORK• PROPOSED 2 -STORY OFFICE BUILDING APPROX 13,000SFGENERAL NOTESVICINITY MAPNo. Description Date1" = 20'-0"21ST FL1" = 20'-0"3SECOND FLPROPOSED AREANameAreaNON. PARK.2197 SFPROPOSED GROUND FLOOR ARE A5460 SFPROPOSED SECOND FLOOR5460 SF13116 SF“NON PARKING AREA” = ELEVATOR, THE STAIRS, THE RESTROOMS AND HALLWAYS UNDER 44 INCHES ARE NOT INCLUDED IN PARKING COUNT SQUARE FOOTAGE 5460 + 5460 = 10920SFTOTAL:NON PARKING AREA = 2197SF
------9' - 6"12' - 0"3' - 7"7' - 2"6' - 10"5 ' - 0 "
5 ' - 0 "A41A4.32MEN'S RESTROOMWOMEN'S RESTROOMELEVATOR14' - 11"8' - 2"9' - 1"4' - 0"1' - 1"4' - 0"7' - 1"4' - 0"9' - 6"4' - 0"1' - 1"4' - 0"11' - 9"4' - 0"1' - 1"4' - 0"6' - 2"1 0 ' - 0 "
2 ' - 8 "
6 ' - 1 "
1 ' - 0 "16' - 0"5' - 0"8' - 0"4' - 0"1' - 1"4' - 0"1' - 1"4' - 0"11' - 9"4' - 0"6' - 2"5' - 9"4' - 0"5' - 11"4' - 0"10' - 4"4' - 0"8' - 8"4' - 0"1' - 2"4' - 1"16' - 5"68' - 4"19' - 1"55' - 0"-A4.12A4.21A4.11A4.31A42CONFERENCE ROOMBREAK ROOMOFFICE OFFICEOFFICE OFFICE OFFICE OFFICESTORAGEBREAK ROOMHALLOFFICEOFFICEBREAK ROOM OFFICE OFFICEHALLLOBBYCONFERENCE ROOMOFFICEOFFICEOFFICE OFFICE OFFICEOFFICEOFFICEOFFICE97' - 9"5 ' - 3 "
4 ' - 0 "
3 ' - 0 "3 1 ' - 8 "25' - 2"D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D3D4D4D3D3D1D3D3D6D6D6D2D4D4D10D9D8D72' - 6"30"48"48"30"2' - 6"2' - 6"EQEQEQEQ1' - 7"1' - 7"15' - 5"3' - 8"ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:25 PM3/16" = 1'-0"10/14/2020 2:01:25 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA2FIRST FLOOR20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGA3/16" = 1'-0"1FIRST FLOORNo. Description DateDOOR SCHEDULEMark Family and Type Width Height CommentsD1 Double-Glass: 50685' - 0" 6' - 8"D2 Single-1_Panel-Wood: 26682' - 6" 6' - 8"D3 Single-1_Panel-Wood: 30683' - 0" 6' - 8"D4 Flush_Door_w_ADA_Clearances_1663: 3'-0" x 7'-0" Flush, 2" Head 3' - 0" 7' - 0"D6 Door-Double-Flush_Panel: 72" x 80"6' - 0" 6' - 8"D7 Curtain Wall-Store Front-Dbl: Store Front Double Door 5' - 9 1/2" 6' - 10 3/4"D8 Curtain Wall Sgl Glass: Curtain Wall Sgl Glass 2' - 9 1/4" 6' - 8 1/4"D9 Curtain Wall Sgl Glass: Curtain Wall Sgl Glass 2' - 8 1/4" 6' - 8 1/4"D10 Curtain Wall Sgl Glass: Curtain Wall Sgl Glass 2' - 8 1/4" 6' - 8 1/4"GROUND FLOOR ROOM SCHEDULEROOM NAME AREAMEN'S RESTROOM100 SFWOMEN'S RESTROOM84 SFELEVATOR53 SFCONFERENCE ROOM240 SFBREAK ROOM231 SFOFFICE95 SFOFFICE95 SFOFFICE95 SFOFFICE95 SFOFFICE95 SFOFFICE95 SFSTORAGE100 SFBREAK ROOM123 SFHALL1274 SFOFFICE100 SFOFFICE100 SFBREAK ROOM121 SFOFFICE98 SFOFFICE98 SFRoom40 SFHALL832 SFLOBBY483 SFCONFERENCE ROOM272 SFOFFICE100 SFOFFICE84 SFOFFICE152 SFOFFICE147 SFOFFICE160 SFOFFICE95 SFOFFICE95 SFOFFICE45 SFWINDOW SCHEDULEMark Family and Type Width Height CommentsSystem Panel: GlazedW1 System Panel: Glazed 0' - 0 15/32" 1' - 8 1/4"W2 System Panel: Glazed 0' - 0 15/32" 6' - 8 1/4"W3 System Panel: Glazed 0' - 7 1/4" 1' - 8 1/4"W4 System Panel: Glazed 0' - 7 1/4" 6' - 8 1/4"W5 System Panel: Glazed 0' - 8 1/4" 1' - 8 1/4"W6 System Panel: Glazed 0' - 8 1/4" 6' - 8 1/4"W9 System Panel: Glazed 1' - 8 1/4" 2' - 2 21/32"W10 System Panel: Glazed 1' - 8 1/4"W11 System Panel: Glazed 1' - 8 1/4" 6' - 8 1/4"W12 System Panel: Glazed 1' - 8 1/4" 6' - 10 27/32"W13 System Panel: Glazed 2' - 8 1/4" 1' - 8 1/4"W14 System Panel: Glazed 2' - 9 1/4" 1' - 8 1/4"W15 System Panel: Glazed 2' - 9 1/2" 2' - 2 21/32"W16 System Panel: Glazed 2' - 9 1/2" 1' - 8 1/4"W17 System Panel: Glazed 2' - 9 1/2" 6' - 10 27/32"W19 System Panel: Glazed 3' - 6 17/32" 1' - 8 1/4"W20 System Panel: Glazed 3' - 6 17/32" 6' - 8 1/4"W21 System Panel: Glazed 3' - 6 17/32" 1' - 8 1/4"W22 System Panel: Glazed 3' - 6 17/32" 6' - 8 1/4"W23 System Panel: Glazed 3' - 7" 1' - 8 1/4"W24 System Panel: Glazed 3' - 7" 6' - 8 1/4"W25 System Panel: Glazed 1' - 8 1/4"W26 System Panel: Glazed 6' - 8 1/4"W27 System Panel: Glazed 3' - 9 1/2" 1' - 8 1/4"W28 System Panel: Glazed 3' - 9 1/2" 6' - 8 1/4"
DNDN------ELEVATORA41A4.3215' - 0"8' - 0"9' - 1"9' - 1"7' - 1"4' - 0"9' - 6"4' - 0"1' - 1"4' - 0"11' - 9"4' - 0"1' - 1"4' - 0"12' - 0"9 ' - 7 "
1 0 ' - 0 "8' - 6"16' - 0"5' - 0"8' - 0"1' - 10"19' - 1"4' - 0"1' - 1"4' - 0"1' - 1"4' - 0"6' - 9"4' - 0"1' - 1"4' - 0"4' - 0"5' - 11"4' - 0"10' - 4"4' - 0"8' - 8"4' - 0"1' - 2"4' - 1"54' - 11"WOMEN'S RESTROOMMEN'S RESTROOM39' - 4"3 3 ' - 9 "6' - 1"68' - 2"5' - 8"6' - 1"16' - 4"-A4.12A4.21A4.11A4.31A42CONFERENCE ROOM BREAK ROOMOFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICEHALLOFFICE OFFICE BREAK ROOMSTORAGEOFFICEOFFICEBREAK ROOMCONFERENCE ROOMOFFICEOFFICEOFFICE OFFICE OFFICEOFFICEOFFICEVESTIBULE0' - 1"97' - 8"D3D3D3D3D3D3D3D3D3D3D3D4D4D3D3D3D3D3D3D3D3D3D3D3D3D4D4D3D3D3D6D6D6D62' - 6"30"48"48"30"2' - 6"2' - 6"EQEQEQEQ1' - 7"1' - 7"ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:25 PM3/16" = 1'-0"10/14/2020 2:01:25 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA2.1SECOND FLOOR20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date3/16" = 1'-0"1SECOND FLWINDOW SCHEDULEMark Family and Type Width Height CommentsSystem Panel: GlazedW1 System Panel: Glazed 0' - 0 15/32" 1' - 8 1/4"W2 System Panel: Glazed 0' - 0 15/32" 6' - 8 1/4"W3 System Panel: Glazed 0' - 7 1/4" 1' - 8 1/4"W4 System Panel: Glazed 0' - 7 1/4" 6' - 8 1/4"W5 System Panel: Glazed 0' - 8 1/4" 1' - 8 1/4"W6 System Panel: Glazed 0' - 8 1/4" 6' - 8 1/4"W9 System Panel: Glazed 1' - 8 1/4" 2' - 2 21/32"W10 System Panel: Glazed 1' - 8 1/4"W11 System Panel: Glazed 1' - 8 1/4" 6' - 8 1/4"W12 System Panel: Glazed 1' - 8 1/4" 6' - 10 27/32"W13 System Panel: Glazed 2' - 8 1/4" 1' - 8 1/4"W14 System Panel: Glazed 2' - 9 1/4" 1' - 8 1/4"W15 System Panel: Glazed 2' - 9 1/2" 2' - 2 21/32"W16 System Panel: Glazed 2' - 9 1/2" 1' - 8 1/4"W17 System Panel: Glazed 2' - 9 1/2" 6' - 10 27/32"W19 System Panel: Glazed 3' - 6 17/32" 1' - 8 1/4"W20 System Panel: Glazed 3' - 6 17/32" 6' - 8 1/4"W21 System Panel: Glazed 3' - 6 17/32" 1' - 8 1/4"W22 System Panel: Glazed 3' - 6 17/32" 6' - 8 1/4"W23 System Panel: Glazed 3' - 7" 1' - 8 1/4"W24 System Panel: Glazed 3' - 7" 6' - 8 1/4"W25 System Panel: Glazed 1' - 8 1/4"W26 System Panel: Glazed 6' - 8 1/4"W27 System Panel: Glazed 3' - 9 1/2" 1' - 8 1/4"W28 System Panel: Glazed 3' - 9 1/2" 6' - 8 1/4"DOOR SCHEDULEMark Family and Type Width Height CommentsD1 Double-Glass: 50685' - 0" 6' - 8"D2 Single-1_Panel-Wood: 26682' - 6" 6' - 8"D3 Single-1_Panel-Wood: 30683' - 0" 6' - 8"D4 Flush_Door_w_ADA_Clearances_1663: 3'-0" x 7'-0" Flush, 2" Head 3' - 0" 7' - 0"D6 Door-Double-Flush_Panel: 72" x 80"6' - 0" 6' - 8"D7 Curtain Wall-Store Front-Dbl: Store Front Double Door 5' - 9 1/2" 6' - 10 3/4"D8 Curtain Wall Sgl Glass: Curtain Wall Sgl Glass 2' - 9 1/4" 6' - 8 1/4"D9 Curtain Wall Sgl Glass: Curtain Wall Sgl Glass 2' - 8 1/4" 6' - 8 1/4"D10 Curtain Wall Sgl Glass: Curtain Wall Sgl Glass 2' - 8 1/4" 6' - 8 1/4"SECOND FLOOR ROOM SCHEDULEROOM NAME AREAELEVATOR54 SFMEN'S RESTROOM99 SFWOMEN'S RESTROOM84 SFCONFERENCE ROOM240 SFBREAK ROOM231 SFOFFICE95 SFOFFICE90 SFOFFICE90 SFOFFICE90 SFOFFICE95 SFOFFICE95 SFOFFICE95 SFHALL1194 SFOFFICE100 SFOFFICE100 SFBREAK ROOM123 SFSTORAGE100 SFOFFICE100 SFOFFICE100 SFBREAK ROOM123 SFCONFERENCE ROOM271 SFOFFICE100 SFOFFICE84 SFOFFICE144 SFOFFICE847 SFOFFICE144 SFOFFICE151 SFOFFICE119 SFOFFICERedundant RoomOFFICE121 SFVESTIBULE495 SF
A4.12A4.21A4.11A42A 411ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"Level 1730' -8"11111111111111232222222221161' - 5"4' - 8"3' - 4"10' - 0"2' - 0"10' - 8"3' - 0"44444442' - 0"27' - 0"555555556333' - 0"30' - 8"1' - 0"7778888881ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"Level 1730' -8"111111111111332222222245454510' - 8"2' - 0"10' - 0"3' - 4"4' - 8"30' - 8"1' - 5"3' - 0"7' - 0"1' - 3"788ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:29 PMAs indicated10/14/2020 2:01:29 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA4EXTERIORELEVATIONS20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date1" = 30'-0"KEYPLANELEVATION KEYNOTESKEYNOTE1 ALUMINUM STOREFRONT SYSTEM2 WALL REVEAL3 ALUMINUM CANOPY4 STONE LEDGER5 NEW CORONADO STONE VENEER6 WOOD TEAK SIDING7 WALL LIGHTS8 OUTDOOR LIGHTS3/16" = 1'-0"1FRONT ELEVATION3/16" = 1'-0"2ELEVATION A
A4.12A4.21A4.11A42A 411ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"Level 1730' -8"1111111111111111111111322222322325' - 0"3' - 0"6541' - 5"1' - 8"2' - 0"54365410' - 8"2' - 0"10' - 0"3' - 4"4' - 8"30' - 8"7' - 0"1' - 0"78881ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"Level 1730' -8"11111111113322222334422551' - 5"2' - 8"0' - 8"1' - 8"2' - 0"4' - 8"3' - 4"10' - 0"2' - 0"1' - 3"1' - 3"1' - 0"7888ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:33 PMAs indicated10/14/2020 2:01:33 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA4.1EXTERIORELEVATIONS20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date1" = 30'-0"KEYPLANELEVATION KEYNOTESKEYNOTE1 ALUMINUM STOREFRONT SYSTEM2 WALL REVEAL3 ALUMINUM CANOPY4 STONE LEDGER5 NEW CORONADO STONE VENEER6 WOOD TEAK SIDING7 WALL LIGHTS8 OUTDOOR LIGHTS3/16" = 1'-0"1RIGHT ELEVATION3/16" = 1'-0"2REAR ELEVATION
A4.12A4.21A4.11A42A 411ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"Level 1730' -8"1111111111111111333322222222452245451' - 0"2' - 0"0' - 8"3' - 0"3' - 4"10' - 0"2' - 0"10' - 8"26' - 0"7' - 0"1' - 4"11788ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:36 PMAs indicated10/14/2020 2:01:36 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA4.2EXTERIORELEVATIONS20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date1" = 30'-0"KEYPLANELEVATION KEYNOTESKEYNOTE1 ALUMINUM STOREFRONT SYSTEM2 WALL REVEAL3 ALUMINUM CANOPY4 STONE LEDGER5 NEW CORONADO STONE VENEER6 WOOD TEAK SIDING7 WALL LIGHTS8 OUTDOOR LIGHTS3/16" = 1'-0"1LEFT ELEVATION
A4.12A4.21A4.11A42A 41 1ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"Level 1730' -8"PT 2PT 4ST 1PT 1WD 1ST 1ST 1PT 4PT 2PT 1PT 1PT 1PT 1PT 4PT 2PT 4ST 1ST 1PT 21ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"Level 1730' -8"ST 1ST 1ST 1PT 2PT 1PT 4PT 1PT 2PT 2PT 4PT 1PT 2PT 2This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/EDS DESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comTEL:951-323-2187CLIENT:D E S I G N SD E S I G N SD E S I G N SD E S I G N SEVERETT SMITH EVERETT SMITH EVERETT SMITH EVERETT SMITH ScaleProject numberAs indicatedML MORTGAGE CORP.8281 UTICA AVE, RANCHO CUCAMONGAA4.3MATERIAL BOARD1" = 30'-0"KEYPLANFRONT ELEVATION 3/16" = 1'-0"1ELEVATION A3/16" = 1'-0"2PT 1PT 2PT 3PT 4ST 1WD 1CORONADO STONE VENEER -CORONADO HONEY LEDGE SIOUX FALLSWoodSTONEWOOD ARCHITECTURAL PANELS ESR-4154SHERWIN WILLIAMS PAINT
ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:50 PM10/14/2020 2:01:50 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA4.4WOOD SPEC20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date
ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:51 PM10/14/2020 2:01:51 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA4.6STONE SPEC20-2028ML MORTGAGECORP.AuthorCheckerNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date
1. FLAT ROOF WITH CLASS 'A' ROOF THROUGHOUT2. BUILDING LINE BELOW3. PARAPET4. CRICKET WITH 5/8" PLYWOOD WITH MINIMUM SLOPE OF 3/8" PER FOOT TYPICAL.5. ROOF DRAIN WITH OVERFLOW6. MECHANICAL PLATFORM. FOR SIZE, CONSULT MECHANICAL DRAWINGS. 7. DUCT FROM BELOW (SEE MECHANICAL FOR ROOF JACK TYPE AND LOCATIONS)8. 6"X4" DRAIN OPENING AT ROOF LEVEL9. A/C UNITS10. SCUPPER11. ROOF STRUCTURE SEE STRUCT.12. 48"x96" 'BRISTOLITE' FIBERGLASS SKYLIGHT, W/13. ROOF ACCESS LADDER2% SLOPE2% SLOPEScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:51 PM1/4" = 1'-0"10/14/2020 2:01:51 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA5ROOF PLAN20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date1/4" = 1'-0"1T.O.P. 2ND
1ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"2A6OFFICEBREAK ROOMHALLOFFICE?OFFICEOFFICE HALL BREAK ROOM OFFICEOFFICE1ST FL0' -0"GRADE-0' -8"T.O. 1ST10' -8"T.O. SECOND22' -8"T.O. ROOF26' -0"SECOND FL12' -8"1A6ELEVATOR WOMEN'S RESTROOMWOMEN'S RESTROOMELEVATORBREAK ROOM OFFICE OFFICELOBBYOFFICEOFFICEBREAK ROOMVESTIBULEVESTIBULELOBBYScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:01:52 PM3/16" = 1'-0"10/14/2020 2:01:52 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA6SECTIONS20-2028ML MORTGAGECORP.RMESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date3/16" = 1'-0"1Section A3/16" = 1'-0"2Section B
ScaleProject numberDateDrawn byChecked byThis document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/ ESDESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comRIVERSIDE COUNTY, CATEL:951-323-2187EEEEVVVVEEEERRRREEEETTTTTTTT SSSSMMMMIIIITTTTHHHH PROJECT:CLIENT NAME:PROJECT ADDRESS:REVISIONS:DDDD S DDDD EEEE SSSS IIII GGGG NNNN SSSSE201910/14/2020 2:02:22 PM10/14/2020 2:02:22 PMZ:\Shared\Everett Smith Designs\___ES Design Jobs\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA\20-2028 8281 UTICA AVE, RANCHO CUCAMONGA 10.14.rteA73D VIEWS20-2028ML MORTGAGECORP.ESESNEW 2 STORY COMMERICALBUILDING8281 UTICA AVE,RANCHO CUCAMONGANo. Description Date
This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Everett Smith, and is not to be used in whole or in part, for any other project without the written authorization of Everett Smith/EDS DESIGNS. All Rights ReservedPREPARED BY:Email: everett@everettsmithdesigns.comTEL:951-323-2187CLIENT:D E S I G N SD E S I G N SD E S I G N SD E S I G N SEVERETT SMITH EVERETT SMITH EVERETT SMITH EVERETT SMITH ScaleProject numberML MORTGAGE CORP.8281 UTICA AVE, RANCHO CUCAMONGAA7.1RENDERINGS
CLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING5Feet1:1204020010
CLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING5FIRE ACCESS PLAN40200Feet1:240203
CITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING5
CLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING5LEGENDTAX ASSESSOR'S PARCEL NO.EARTHWORK QUANTITIESLAND AREA:PRELIMINARY GRADING PLANFORPROPOSED OFFICE BUILDING8281 UTICA AVENUECITY OF RANCHO CUCAMONGA’’” ” ’ GRADING GENERAL NOTES:GRADING GENERAL NOTES (CONTINUED):CIVIL ENGINEER'S NOTICE TO CONTRACTOR:UTILITY PURVEYORS:OWNER/DEVELOPER.INDEX OF SHEETS:NOTE:1
CLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING5Feet1:1202010052
SECTION ASection DSECTION BSECTION CSection ESection FCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING53
CLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING54FeetSCALE 1" = 20'201005
CLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCLEAN AIR/VANPOOL/EVCITY OF RANCHO CUCAMONGA8281 UTICA AVE.RANCH CUCAMONGA, CA 91730PROPOSED OFFICE BUILDING55
SHEET NO. SHEET TITLEE1.0 PHOTOMETRIC STUDYE2.0 SPECIFICATION SHEETSPROJECT #:PROJECT NAME:PROJECT ADDRESS:23905 Clinton Keith Rd 114-381Wildomar, Ca 92595951-902-6600info@winstoneng.comwww.winstoneng.com3/30/20INITIAL RELEASE8281 UTICA AVERANCHO CUCAMONGA, CA 91730REVISION SCHEDULEISSUEDATEThese drawings and specifications, and ideas, designs andarrangements represented are and shall remain the property ofthe engineer. No part shall be copied, disclosed to others orused in connection with any work or project other than thespecific project for which they have been prepared withoutwritten consent of the engineer. Visual contact with thesedrawings and specifications shall constitute evidence ofacceptance of these restrictions. Submittal of documents topublic agencies shall not be considered a waiver of Engineer.Copy ProtectionOFFICE BUILDING PARKING LOT LIGHTING PHOTOMETRIC10/20/20UPDATE BACKGROUNDE1.0PHOTOMETRIC STUDY328-1
PROJECT #:PROJECT NAME:PROJECT ADDRESS:23905 Clinton Keith Rd 114-381Wildomar, Ca 92595951-902-6600info@winstoneng.comwww.winstoneng.com3/30/20INITIAL RELEASE8281 UTICA AVERANCHO CUCAMONGA, CA 91730REVISION SCHEDULEISSUE DATEThese drawings and specifications, and ideas, designs andarrangements represented are and shall remain the property ofthe engineer. No part shall be copied, disclosed to others orused in connection with any work or project other than thespecific project for which they have been prepared withoutwritten consent of the engineer. Visual contact with thesedrawings and specifications shall constitute evidence ofacceptance of these restrictions. Submittal of documents topublic agencies shall not be considered a waiver of Engineer.Copy ProtectionOFFICE BUILDING PARKING LOT LIGHTING PHOTOMETRIC10/20/20UPDATE BACKGROUNDE2.0SPECIFICATION SHEETS328-1