HomeMy WebLinkAbout2021-09-14 SupplementalSerge Bonaldo for Bernell HydraulicsDRC2021-00166September 14, 2021
Who:Serge Bonaldo for Bernell Hydraulics
What:A request for site plan and architectural review of a 21,221 square foot
industrial building on 2.87 acres of land.
Where:East side of Etiwanda Avenue and south of Whittram Avenue
Entitlements:Design Review DRC2021-00166
Conditional Use Permit DRC2021-00304
Project Description
Land Use General Plan Zoning
Site Industrial Buildings/Vacant Land General Industrial Neo Industrial (NI) District
North
Single-Family Residence/
Vacant land General Industrial Neo Industrial (NI) District
South
Rail Right-of-Way/
Recycling Facility Heavy Industrial Industrial Employment (IE)
District
East Vacant Land General Industrial Neo Industrial (NI) District
West Industrial Buildings General Industrial Neo Industrial (NI) District
Location
Site Plan
Enlarged Site Plan
Development Requirements
Development Standard Required Provided Compliant?
Building Setback (Street)25 Feet 25 Feet Yes
Building Setback (Side)5 Feet 40 and 50 Feet Yes
Building Setback (Rear)0 Feet 135 Feet Yes
Parking Setback 15 Feet 25 Feet Yes
Landscape Depth 25 Feet 25 Feet Yes
Landscape Coverage 10 Percent 10.27 Percent Yes
Floor Area Ratio 50 –60 Percent 30 Percent Yes
Building Height 35 –75 Feet 32 Feet Yes
Parking Requirements
Use Parking Ratio Required Parking Provided Parking
Existing Warehouse
(9,137 SF)
1:1,000 SF 10
Existing Retail/Office
(1,000 SF)
1:250 4
Existing Vehicle
Repair
(6,351 SF)
1:400 SF 16
New Truck Service
(3,024 SF)
1:400 SF 8
Production Repair
(9,111 SF)
1:500 SF 18
Warehouse
(3,509 SF)
1:1,000 4 Spaces 47 Spaces
Office/Retail*
(3,991 SF)
1:250 SF 16 Spaces 32 Spaces
Total Vehicle Parking 76 Spaces 76 Spaces
*1,586 SF Reduction for Hallways, Stairs, Bathroom, and Mechanical Rooms
Design Overview
•The proposed building will be of concrete tilt-up construction and will be
painted multiple shades of gray along with the tenant’s company color –red;
•Each elevation includes glazing with metal awnings,with building pop-outs on
the north and south elevations to provide visual interest;
•Building pop-outs are proposed on the north and south elevations to provide
wall plane articulation and visual interest;
•The required 500 square foot employee outdoor eating area will be located
south of the proposed building and will include an overhead shade cover,
multiple dining tables,and a trash receptacle.
Conclusions
Staff supports the project for the following reasons:
•Well designed building and site layout;
•The project complies with all Development Code
requirements including parking,building and parking
setbacks,floor area ratio and landscape coverage;
Staff Recommendation
•Staff requests that the Design Review Committee consider
the design (building architecture,site planning,etc.)of the
proposed project and recommend approval of the design of
the project as proposed by the applicant.