Loading...
HomeMy WebLinkAbout2022-04-27 - Agenda Packet HISTORIC PRESERVATION COMMISSION AND PLANNING COMMISSION MEETING AGENDA RANCHO CUCAMONGA CIVIC CENTER COUNCIL CHAMBERS 10500 CIVIC CENTER DRIVE RANCHO CUCAMONGA, CALIFORNIA April 27, 2022 7:00 p.m. A. Call to Order and Pledge of Allegiance Roll Call: Chair Dopp Vice Chair Williams Commissioner Morales Commissioner Boling Commissioner Daniels B. Public Communications This is the time and place for the general public to address the Planning/Historic Preservation Commission (“Planning Commission”) on any Consent Calendar item or any item not listed on the agenda that is within the Commission’s subject matter jurisdiction. The Planning Commission may not discuss any issue not included on the agenda but may set the matter for discussion during a subsequent meeting. C. Consent Calendar C1. Consideration to adopt Regular Meeting Minutes of April 13, 2022. D. Public Hearings D1. LOCATED AT THE NORTHWEST CORNER OF FOOTHILL BOULEVARD AND MILLIKEN AVENUE - WDCC MILLIKEN WEST RESIDENTIAL, LLC - A request to establish a Master Plan and construct a mixed-use development comprising of 671 apartments and 20,841 square feet of commercial space within the Mixed-Use Urban Corridor (MU-UCR) District, APNs: 1077-422-51, -55, -98, -99, 1090-121-38, and -39. (Design Review DRC2021-00120, Tentative Tract Map 20120 (SUBTT00024), and Master Plan DRC2022-00074) D2. LOCATED AT THE SOUTHWEST OF DAYTON DRIVE AND BUFFALO AVENUE – CONDITIONAL USE PERMIT DRC2022-00053 - PARAMOUNT LOGISTICS - A request to operate an 85,026 square foot Warehouse, Storage, and Distribution (Medium) land use in the Neo Industrial (NI) District at 11601 Dayton Drive; APN: 0229-262-09. The project qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 – operation, permitting, leasing, or minor alteration of existing structures. HPC/PC Agenda – April 27, 2022 Page 2 of 3 If you need special assistance or accommodations to participate in this meeting, please contact the Planning Department at (909) 477-2750. Notification of 48 hours prior to the meeting will enable the City to make reasonable arrangements to ensure accessibility. Listening devices are available for the hearing impaired. D3. Consideration of a Recommendation to the City Council to Adopt a Comprehensive revision to Title 17 (Development Code) of the Rancho Cucamonga Municipal Code, Adopt a Revised Zoning Map and Repeal or Amend Several Specific Plans, Planned Communities and Master Plans to Implement the Goals and Policies of the General Plan. This Item Will be Forwarded to City Council for Final Action. E. Director Announcements F. Commission Announcements G. Adjournment TO ADDRESS THE PLANNING COMMISSION The Planning Commission encourages free expression of all points of view. To allow all persons to speak, given the length of the agenda, please keep your remarks brief. If others have already expressed your position, you may simply indicate that you agree with a previous speaker. If appropriate, a spokesperson may present the views of your entire group. To encourage all views and promote courtesy to others, the audience should refrain from clapping, booing or shouts of approval or disagreement from the audience. The public may address the Planning Commission on any agenda item. To address the Planning Commission, please come forward to the podium. State your name for the record and speak into the microphone. After speaking, please complete a speaker card located on the podium. It is important to list your name, address (optional) and the agenda item letter your comments refer to. Comments will be limited to 5 minutes per individual. If a large number of individuals wish to speak on an item, the Chair may limit the time to 3 minutes in order to provide an opportunity for more people to be heard. Speakers will be alerted when their time is up, and no further comments will be permitted. If you wish to speak concerning an item not on the agenda, you may do so under “Public Communications.” Any handouts for the Planning Commission should be given to the Planning Commission Secretary for distribution to the Commissioners. A copy of any such materials should also be provided to the Secretary to be used for the official public record. As an alternative to participating in the meeting, you may submit comments in writing to Elizabeth.Thornhill@cityofrc.us by 12:00 p.m. on the date of the meeting. Written comments will be distributed to the Commissioners and included in the record. All requests for items to be placed on a Planning Commission agenda must be in writing. Requests for scheduling agenda items will be at the discretion of the Commission and the Planning Director. HPC/PC Agenda – April 27, 2022 Page 3 of 3 AVAILABILITY OF STAFF REPORTS Copies of the staff reports or other documentation to each agenda item are available at www.CityofRC.us. APPEALS Any interested party who disagrees with the City Planning Commission decision may appeal the Commission’s decision to the City Council within 10 calendar days. Any appeal filed must be directed to the City Clerk’s Office and must be accompanied by a fee of $3,279 for all decisions of the Commission. (Fees are established and governed by the City Council). Please turn off all cell phones while meeting is in session. Copies of the Planning Commission agendas, staff reports, and minutes can be found at www.CityofRC.us. I, Elizabeth Thornhill, Executive Assistant of the City of Rancho Cucamonga, or my designee, hereby certify that a true, accurate copy of the foregoing agenda was posted on Thursday, April 21, 2022, seventy-two (72) hours prior to the meeting per Government Code 54954.2 at 10500 Civic Center Drive. Historic Preservation Commission and Planning Commission Agenda April 13, 2022 MINUTES Rancho Cucamonga, CA 91729 7:00 p.m. The regular meeting of the Historic Presentation Commission and Planning Commission was held on April 13, 2022. The meeting was called to order by Chair Dopp 7:01 p.m. A. Roll Call Planning Commission present: Chair Dopp, Commissioner Morales, Commissioner Boling and Commissioner Daniels; Commissioner Williams. Staff Present: Serita Young, Assistant City Attorney; Matt Burris, AICP, LEED AP, Deputy City Manager-Community Development, Interim Planning Director; Jennifer Nakamura, Deputy Director of Planning; Mike Smith, Principal Planner; Brian Sandona, Principal Civil Engineer; David F. Eoff IV, Senior Planner; Lori Sassoon, Deputy City Manager, Administrative Services; Noah Daniels, Finance Director; Sean McPherson, Senior Planner; Vincent Acuna, Associate Planner; Elizabeth Thornhill, Executive Assistant. B. Public Communications Chair Dopp opened public communications and hearing no one, closed public communications. C. Consent Calendar C1. Consideration to adopt Regular Meeting Minutes of March 23, 2022. Motion to adopt by Vice Chair Williams, second by Commissioner Boling. Motion carried unanimously 5-0 vote. D. Public Hearing D1. LOCATED ON THE SOUTHEAST CORNER OF FOOTHILL BOULEVARD AND ETIWANDA AVENUE – WOOD PARTNERS – A request to construct a mixed-use development comprising of 259 residential units, 2 commercial units totaling 2,253 square- feet, and 1 live/work unit with 816 square feet of non-residential space within the Urban Corridor (UCR) District. APNs: 0229-311-14 and -15. A Mitigated Negative Declaration of environmental impacts has been prepared for consideration. Design Review DRC2020- 00440. Vincent Acuna, Associate Planner, presented Commissioners with a Staff Report and presentation (copy on file). Commissioner Daniels expressed he likes the project, it’s well designed. He mentioned he would like to see more commercial with this project. He noticed there is only one live/work unit. He asked applicant to address. He commented the ball court is at a strange location. He asked what type of commercial would be going into project, and if the developer have any tenants in mind. Lastly, he confirmed with Vincent Acuna on the assigned parking map that guest parking is in purple. HPC/PC MINUTES – April 13, 2022 Page 2 of 9 Draft Chair Dopp asked what are some of the benchmarks the City is looking at when determining something meets mixed-use criteria in terms of mix of uses between commercial and residential Vincent Acuna explained that a mixed-use development would have two or more uses but in addition to having mixed-use within that project itself, it’s also important to view the mixed of uses in the context of the larger neighborhood. In terms of this project, answering Commissioner Daniels question, the reason why there is one live/work unit is because the project was submitted under an SB330 application. This meant that the City, cannot reduce the project density as proposed. Originally, the project had five live-work units and when four live- work units were converted to two true commercial tenant spaces, this left one live-work unit. He explained what constitutes a mixed-use, it has to be completely separate from the living unit. Commissioner Daniels asked what the ratio is between residential and commercial space. Vincent Acuna answered 1.5 % of the project is commercial. Serita Young, Assistant City Attorney, mentioned as a reminder, that the project is under SB330, which means under that legislation, the City will not be able to lower the density of a project as proposed complies with the City’s objective standards. In short, if increasing commercial square footage will reduce the number of residential units proposed, this cannot be done. Ms. Young also noted time limits for reviews related to SB330 projects. Commissioner Williams stated she is disappointed the project did not have a dedicated tot lot. She explained a tot lot is a place where they can bring their kids to play before taking a nap. There are 2- and 3- bedroom units and they will have children. You need a place for children to play, otherwise, they will destroy the property. She firmly believes you need a place to take your children to be children. She also said the bocce ball court on Foothill should be indoors where it’s more private. She asked applicant to address these issues. Chair Dopp opened public hearing. Joe Gambill, Applicant, mentioned they added more parking spaces. All residents have assigned parking. They also have security cameras on-site staff to enforce the parking management plan. He mentioned bocce ball could be moved if it’s an an issue. He added this property will be managed by Wood Partners, which is the same company as the developer. Lindsay Tabaian, Law Firm of Allan Matkins, representing the applicant, spoke about the letter received from Lozeau Drury firm. She said after reviewing the 641 pages received today, there are no new comments in this letter that are not adequately addressed in the IS/MND that was circulated for public review, which is part of this public record of proceedings tonight. She stated the IS/MND complies with CEQA, is complete and addresses all comments including those raised in this letter. There is no further response or changes to the environmental document are needed based on these comments. Chair Dopp asked what Lindsay thinks about some of the arguments in the letter. Chemical formaldehyde being present and a risk, diesel being harmful and a threat to public health, and a large amount of wildlife being killed as a result of the project. He asked what her response is from an environmental perspective considering she is an expert in the field. HPC/PC MINUTES – April 13, 2022 Page 3 of 9 Draft Lindsay Tabaian responded that the comment about formaldehyde is an unsubstantiated comment, which assumes that wood containing formaldehyde would be used in connection with the project. She said it’s a new construction that has to comply with very strict environmental standards in terms of the types of material used on-site. Compliance with those environmental standards would ensure that none of the formaldehyde type impacts raised in the letter would occur on-site. She explained the diesel particulate emissions is not an issue on this site. She said in the original letter they included a screening Health Risk Assessment (HRA) for construction, which alleged there would be diesel particulate and other air quality and GHG impacts. Although an HRA is not required for a project of this type, the applicant prepared their own detailed health risk assessment. It concluded there would be no diesel particulate impacts associated with the project. She spoke about impacts on wildlife. The biological assessment concluded that there would not be any significant biological impacts. The IS/MND was done to the satisfaction of the CA Fish and Wildlife. Chair Dopp thanked her for her explanation and opened the public hearing. The following persons commented on the project: • Jordan Sisson, on behalf of Lozeau Drury, states the IS/MND was not up to standard and requested the commission not take any action on the project until revisions are made. • Eliseo Flores, resident, raised concerns about project affecting the neighborhood in terms of parking and traffic. • Marcos Rico, resident, raised following concerns: Traffic, noise and light pollution. For the record, it is noted that the following correspondence was received after the preparation of the agenda packet and the following general concerns are noted. The actual correspondence should be referred to for details: • Letter from Lozeau Drury, stating that the IS/MND failed as an informational document and the project may have adverse environmental impacts. Request an Environmental Impact Report EIR be prepared, pursuant to the California Environmental Quality Act (CEQA). • Email received from Cain Estrada, resident, mentioned he is not against the project, but has traffic concerns for the safety of his children. Jason Pack, Principal with Fehr and Peers, responded to the traffic comments. He said the City did require a full traffic study and the assessment identified Etiwanda and Foothill is congested and currently not operating as well as it should. As such, the project will be making significant improvements to the North bound approach and to the East bound approach and making frontage improvements along Foothill. Regarding parking, he said they did provide in their parking memo for variety national parking rates for similar type developments and took surveys at a similar development in Upland. He stated that number of parking spaces provided for this project is significantly more than a similar development in Upland. They felt comfortable that there will be adequate parking. There is a condition of approval to ensure compliance with the parking management plan. Commissioner Daniels stated that each tenant will have assigned parking. He asked about EV charging stations in the subterranean parking garage. Ted Young, Architect, responded that there are EV charging stations in the subterranean garage. Commissioner Daniels asked how EV charges are assigned to tenants. HPC/PC MINUTES – April 13, 2022 Page 4 of 9 Draft Ted Young responded that EV stalls will be installed as needed. He said that, under the management plan, there will be flexibility assigning those stalls permanently for someone who has electric car, or where people can share it. Commissioner Daniels asked how you determine the amount of EV spaces provided. Ted Young answered that it is based in the Green Building Code, which currently requires 10% of all stalls to be EV ready. Lindsay Tabaian stated the Lozeau Drury’s very long letter does not include any new substantial evidence or studies, other than a few statements from the experts in the record about how the comments/response letter were not good enough in their expert opinion. She said there are other factual reports that are offered that were not already included with the October 1st material that were reviewed and responded to in detail. Joe Gambill responded to resident concerns about light pollution. He explained all light standards in parking lot are 14 ft. high, within city requirements. He also clarified that a 6-foot-high block wall will be installed along the south and east property lines abutting residential property to further reduce light pollution. Commissioner Williams suggested adding a swing set. She said your tenants would appreciate it and she will be very happy. Joe Gambill stated they can do that. Commissioner Morales asked what significant things they will do to help with the traffic and how much the intersection improvement would cost Joe Gambill explained that along Etiwanda running north, they are dedicating a traffic and bike lane from the existing property. North of Foothill running east and west they are installing a bus lane. The existing traffic signal on the corner, will be moved. He does not know exact dollar amount. He can follow up. Chair Dopp confirmed with Vincent Acuna it’s in the Conditions Item #5 for Engineering. Vincent Acuna replied yes. Commissioner Boling confirmed that the Standard Condition of Approval, Planning Department Item #33, a 6 ft. block wall will be constructed along the north and east property lines of the project, abutting single-family residential property. Commissioner Boling expressed appreciation to the applicant for considering the neighborhood and residents that surround it and for the project meeting the city’s parking requirements. He said they have done a good job trying to increase the number of parking stalls on site. Regarding the tot lot amenities, he asked will they be up and available during the day/evening hours or does it have to be set up and taken down periodically. Joe Gambill replied we have storage units to put them in. He said you would request from property manager to check out and return when done. HPC/PC MINUTES – April 13, 2022 Page 5 of 9 Draft Commissioner Boling mentioned that the two commercial units have great visibility along Foothill Blvd. He asked how customer parking would work, as well as loading/unload, as the nearest parking space is roughly 200 feet from the units themselves. Joe Gambill replied that the customers, employees, and deliveries would primarily park toward the rear of the project and utilize the sidewalks to get to the commercial units. Commissioner Boling asked if there were dedicated loading zones for the commercial units. Joe Gambill answered no. He said with the parking spaces can coordinate deliveries. Commissioner Boling expressed that he wants to make sure that the tenants of the commercial space have a clear understanding of where their customers will park and where the deliveries can be accommodated. Chair Dopp suggested to flip the commercial and visitor parking in the north side with the 12 and 6 units and maybe during off hours. Joe Gambill replied yes, that could be done. Chair Dopp mentioned he has concerns of the location of bocce ball being close to Foothill. Not the best placement if it will be actively utilized. Joe Gambill responded it can be relocated. Commissioner Boling asked about underground utilities. Is it anticipated that the utilities will be underground. Brian Sandona, Senior Civil Engineer, answered yes, they are conditioned to underground utilities along Etiwanda and Foothill. Commissioner Boling expressed that he appreciates the project. The architecture height variations and color scheme of the project looks good. The project, as a whole, with a mix of units 1, 2, and 3 bedrooms, along with design and amenities is good. It’s appreciated. Commissioner Boling asked about the bus lane, and if it was going to be included as part of the dedication on Foothill Blvd. Joe Gambill confirmed. Chair Dopp mentioned since he and Commissioner Williams saw this project at Design Review Committee meeting, they talked about events programming in Wood Partners project in Chair Dopp asked if they feel comfortable with bocce ball being a good amenity. Joe Gamble explained they had a similar arrangement in Upland where they had a bocce ball court and horseshoes, along the entrance of the building, and it worked really well. He said they would be happy to move it if it’s an issue. Chair Dopp closed public hearing. HPC/PC MINUTES – April 13, 2022 Page 6 of 9 Draft Commissioner Morales stated if we were to approve this, they would have Conditions of Approval (COA) for a Parking Management Plan. He asked staff to explain the parking management plan, and if there is a parking problem what the City can do to help correct that. Brian Sandoval, Sr. Civil Engineer, explained the City does not necessarily advocate for a parking district but residents may petition for a parking district. Commissioner Morales reiterated that the City has an enforcement tool to make the owner of the property take corrective action if parking becomes an issue. Brian Sandona replied not necessarily the enforcement for the owner of the property, but the COA allows the City to facilitate the initiation of parking district in the event that the residents vote for it. Serita Young, Assistant City Attorney, stated Commissioner Morales might be asking about parking management plan and in terms of how the City might enforce should there be an issue. David Eoff, Senior Planner, stated that if there was an observed violation, we would contact the property owner and bring to their attention and do our own observations. There could be the ability to do a parking district/pass, a resident parking permit system. could be signage that could be installed. He said the important thing is to make sure the parking management is being complied with. Vincent Acuna, Associate Planner, mentioned that the applicant has provided a parking management plan. Part of the purpose of this condition is to ensure that if Wood Partners was to sell this building to someone else, there is a condition of approval in this project to assure the parking management plan would be followed by the new owner. Chair Dopp asked staff if they feel comfortable that these numbers are going to be correct at the end of the day. He asked are they confident the number of parking spaces needed is going to greatly exceed and put impacts on the community. David Eoff replied that they are comfortable with the project meeting parking. With the parking management plan and, the COA the city can effectively monitor the site and rectify issues as necessary. Vice Chair Williams stated she realizes she was a little critical initially, but overall, the project is very nicely done. It will make a nice addition to the community. She likes the idea of the monthly activities, but a simple little swing set will make a world of difference. Commissioner Morales mentioned we had a lot of good comments from the public today. Residents, Mr. Flores and Mr. Rico. He said if there were not enough parking spaces, there would be no way he could support it because he feels the City’s responsibility and Commissioners are to avoid harm to the neighborhood. He believes the traffic improvements the developer will do to fix the traffic problems will most definitely help. A 6 ft. wall that was already mentioned will protect the views and privacy around the neighborhood. The parking plan is very crucial. He likes the design of the Paseo with trees and sitting area; it’s a plus. With the developer and City working together and listening to the resident’s concern, they created project that that he can support. Commissioner Boiling expressed his appreciation of staff and their comments regarding the parking management plan. He said it’s wonderful to have in place but in practice, the critical element is management of it, which falls upon the property owner. He is glad it will be managed by Wood Partners after its built and occupied. He hopes they appreciate all comments heard today. They have done a HPC/PC MINUTES – April 13, 2022 Page 7 of 9 Draft wonderful job as an organization, addressing concerns previously brought up, and making adjustments as needed. Working with your residents and commercial tenants, and keeping fingers crossed, they will succeed. The commercial spaces can be challenging spot, depending on the type of tenants brought in. He said that the developer should be mindful of that. However, overall, it’s a good project. Commissioner Daniels mentioned he likes the project and it’s a good location. It is going to give benefit to the city. He knows they are meeting code requirements but personally would like to see more commercial to future mixed-use developments. He believes with a project this size there needs to be more commercial. He said the ball court should be relocated or eliminated. He agrees with Williams on the swing set. With the number of residents, a swing set would be a real asset to the project. Overall, it’s a very good project. Chair Dopp asked Commissioners to come to a consensus on whether they want to actually move the bocce courts and if the commissioners wanted to move the commercial parking. Commissioner Boling stated regarding the parking, we should leave it up to the applicant to best determine service ability of those two commercial units, as well as live/work. Commissioner Williams expressed she is very comfortable asking to relocate or eliminate bocce ball. Maybe make it into a nice sitting area with umbrellas and a fireplace. It is concerning to her the ball going over the wall to Foothill Blvd. It is one of the most crowded streets we have. Commissioner Boling suggested instead of calling it bocce ball, maybe just an open court type area. David Eoff mentioned the idea behind it was to provide additional amenity to public service. He said staff could work with the applicant to be adjusted if so desired by the Commission. Chair Dopp closed with the following comments: It’s very clear to the applicants and future mixed-use developments, we are paying close attention to parking. This project meets the need for our community. It’s very well designed. It’s an attractive development. He is comfortable with the IS/MND. No further written evidence is needed at this point. The concerns were addressed appropriately. Motion to adopt by Commissioner Boling, second by Vice Chair Williams, with the proposed change to Condition of Approval Item #5. Motion carried unanimously 5-0 vote. Adopting Resolution 22-09. E. General Business E 1. Consideration of a Resolution Making Findings of General Plan Conformance for the Rancho Cucamonga EIFD’s Infrastructure Financing Plan, and Making other Findings Related to the Formation of the EIFD and Actions of the EIFD Public Financing Authority. Lori Sassoon, Deputy City Manager, Administrative Services and Noah Daniels, Finance Director, presented Commissioners with a Staff Report. Lori Sassoon mentioned input from Commissioners are welcome as stakeholders, and their feedback will be taken into consideration. Commissioner Boling commended staff on taking a very innovative and unique approach to looking at future financing of projects that would provide an economic benefit to stimulate development within the city. Commissioner Daniels asked if there is a deadline for the County to respond if they want to participate. He asked can they join after it’s formed. HPC/PC MINUTES – April 13, 2022 Page 8 of 9 Draft Lori Sassoon responded she is having discussion with the County. She is hopeful for their participation. It would jump start these investments. She said if they were to consent to join in the next several months, it’s administratively easier, but they can join in a later date. Chair Dopp asked does the money that gets captured by EIFD take away from the City’s general fund. Lori Sassoon answered it captures a piece of the growth that would not otherwise happen if it were not for these investments. Chair Dopp stated it fits the vision of the General Plan holistically in terms of helping take cars off the road and prove the value that can potentially be brought from a parking perspective in the City’s Civic Center district. Motion to adopt by Commissioner Boling, second by Commissioner Morales. Motion carried unanimously 5-0 vote. Adopting Resolution 22-08. E2. Study Session on the Development Code Update. Jennifer Nakamura, Deputy Director of Planning, presented Commissioners with a Staff Report and presentation (copy on file). Commissioner Daniels commented that form-based code is a wonderful idea. Staff did a great job presenting it. Commissioner Boiling stated form-base helps those that are not in the development business see and understand the look, the feel, the connectivity of similar situated developments, they all interact. It will help create an understanding of the economic development impact on some of the projects and what they bring to the city. Commissioner Morales mentioned that it is good that we get this done so the developers get moving on their projects. Vice Chair Williams agrees with what has been said. It’s simple, this is what we want. She likes the attitude of it. It’s modern and uplifting. She is in support of it. Chair Dopp commented that looking at the form base code, he asked is the nonresidential requirement for mixed use projects the metric we will be using in the future. Jennifer Nakamura answered yes it is. With no further discussion, Chair Dopp thanked Jennifer Nakamura and looks forward to seeing this move forward soon. Report has been received and will be filed. F. Director Announcements - None G. Commission Announcements - None H. Adjournment HPC/PC MINUTES – April 13, 2022 Page 9 of 9 Draft Motion by Vice Chair Williams, second by Commissioner Boling to adjourn the meeting, motion carried unanimously, 5-0 vote. Meeting was adjourned at 9:40 p.m. Respectfully submitted, ________________________ Elizabeth Thornhill Executive Assistant, Planning Department Approved: DATE: April 27, 2022 TO: Chairman and Members of the Planning Commission FROM: Matthew R. Burris, AICP, Deputy City Manager – Community and Economic Development/Interim Planning Director INITIATED BY: Vincent Acuna, Associate Planner SUBJECT: LOCATED AT THE NORTHWEST CORNER OF FOOTHILL BOULEVARD AND MILLIKEN AVENUE - WDCC MILLIKEN WEST RESIDENTIAL, LLC - A request to establish a Master Plan and construct a mixed-use development comprising of 671 apartments and 20,841 square feet of commercial space within the Mixed-Use Urban Corridor (MU-UCR) District, APNs: 1077-422-51, -55, -98, -99, 1090-121- 38, and -39. (Design Review DRC2021-00120, Tentative Tract Map 20120 (SUBTT00024), and Master Plan DRC2022-00074) RECOMMENDATION: Staff recommends the Planning Commission take the following action: • Approve Design Review DRC2021-00120 and Tentative Tract Map 20120 (SUBTT00024) through the adoption of the attached Resolution of Approval with Conditions. • Recommend to City Council the approval of Master Plan DRC2022-00074 through the adoption of the attached Resolution of Approval with Conditions. EXECUTIVE SUMMARY: A request to establish a Master Plan and construct a mixed-use development with 671 apartment units and 20,841 square feet of commercial space on a 17.2-acre site. BACKGROUND: The 17.2-acre project site is located at the northwest corner of Foothill Boulevard and Milliken Avenue and is zoned Mixed-Use Urban Corridor (MU-UCR) District. The project site covers approximately three-fourths of the city block bordered by Elm Avenue to the west, Milliken Avenue to the east, Church Street to the north, and Foothill Boulevard to the south (Exhibit A - Aerial). The project site is “L” shaped with frontages along Elm Avenue, Church Street, Milliken Avenue, and Foothill Boulevard, interrupted only by an existing shopping center located at the northeast corner of Elm Avenue and Foothill Boulevard. The site slopes from north to south and is covered by low vegetation. The existing Land Use, General Plan and Zoning Designations for the project site and adjacent properties are as follows: Land Use General Plan Zoning Site Vacant City Corridor High Mixed Use - Urban Corridor (MU-UCR) District North Multifamily Residential Suburban Neighborhood Moderate Medium High (MH) Residential District 1 South Commercial/Retail Pad Buildings/Uses City Corridor High Financial, Restaurants, Residential (MFC) District 1,2 Page 2 of 7 PROJECT ANALYSIS: A. Overview and Site Layout: The project has a proposed density of 39 dwelling units per acre, meeting the density range of 36 to 60 dwelling units per acre required by the City Corridor High General Plan Designation. Two interior streets running north to south and east to west split the project into four areas, creating a block network within the site (Exhibit B – Detailed Site and Landscape Plan). A description of what is proposed for each block/quadrant as well as the project’s interior streets are outlined below: i.) Interior Streets Two interior streets running north to south and east to west are proposed within the project site. The north-south interior street runs from Church Street and connects to an existing driveway leading to Foothill Boulevard. The east-west interior street runs from Milliken Avenue and connects to an existing driveway leading to Elm Avenue. These interior streets are designed with the look, feel, and function of neighborhood streets to help create an urban environment that is envisioned by the General Plan. The urban environment is enhanced further with proper building placement along the streets, “on-street” angled parking, and appropriate landscape features. The interior streets intersect toward the center of the project, creating a balanced circulation pattern throughout the site. ii.) Northwest and Northeast These two blocks are primarily comprised of 3-story walk-up apartments with entrances oriented either toward the project boundaries abutting public streets or the interior streets within the site. Stand-alone garages, surface parking areas, and trash enclosures are plotted within the interior of these two blocks, screening these facilities from public view. iii.) Southwest A clubhouse, pool, and dog park occupy this block. The clubhouse contains the leasing office, fitness center, and multi-purpose room. The clubhouse building is oriented towards the project’s two interior streets. The southern portion of block abuts a parking area for an existing shopping center. iv.) Southeast This block contains a four-story “wrap” building, where residential and commercial units wrap around an above-ground parking structure. All 20,841 square feet of commercial and restaurant space proposed for the project is contained within the Foothill Boulevard ground frontage of the wrap building. As such, a small surface parking lot is proposed west of the wrap building, primarily servicing the commercial spaces. Building entrances are proposed along all four sides of the building for pedestrians, while vehicle entrances to the parking structure are available along the west and north elevation. The wrap building “anchors” the project site with great building placement along Foothill Boulevard and Milliken Avenue. The wrap building’s setback ranges from 0 feet to 20 feet from the property line along Foothill Boulevard, creating a significant architectural presence at a primary intersection in the city. The setback range also allows opportunity for enhanced sidewalk widths and outdoor dining/gathering space to support the ground-floor commercial and encourage a walkable environment. B. Architecture: All buildings within the project site are designed in the modern interpretation of the classic American farmhouse. Design elements that reinforce the farmhouse architecture include batten board siding, corrugated metal awnings, wood railings, sloped roofs, and a primarily white and gray color scheme. Shopping Center Industrial Park (IP) District3 East Hospital (part) City Corridor High Hospital and Related Facilities, Office (MHO) District 1 Vacant (part) West Shopping Center City Corridor High Community Commercial (CC) District 1 1 – Terra Vista Planned Community; 2 – north of Foothill Boulevard; 3 – south of Foothill Boulevard Page 3 of 7 Contemporary architectural elements such as horizontal wood siding, stucco, flat roofs, large windows, and horizontal metal beams are also incorporated into the buildings, giving the farmhouse design a modern appearance. All building materials are carried to all elevations. Horizontal articulation along the building planes as well as vertical articulation on rooflines breaks down the building massing and creates architectural interest (Exhibit C – Elevations, Unit Plans, and Renderings). The ground floor commercial frontages on the south side of the wrap building (facing Foothill Boulevard) are treated with a variety of architectural elements that blend the farmhouse and modern styles together (Exhibit D – Partial Foothill Elevation). Elements such as corrugated metal awnings and eyebrow canopies placed at different heights and distances from the curb, further enhance the overall architecture by creating visual interest and variation at the storefronts. Additionally, the commercial space is designed with a ceiling height of roughly 16 feet to accommodate a range of commercial uses, as required by the General Plan. C. Unit Composition and Floor Plans: All residential units will be housed in either 3-story walk-ups on the northeast and northwest portions of the site, or within the 4-story wrap building at the site’s southeast corner. A total of 323 and 348 units will be located within the 3-story walk-ups and the 4-story wrap building, respectively, with the project providing a grand total of 671 apartments. Studios range in size from 488 to 659 square feet, while 1-bedroom units range from 634 to 1,004 square feet. 2-bedroom units range from 933 to 1,261 square feet. Additionally, 20,841 square feet of ground floor commercial space is located along the 4-story wrap building’s Foothill Boulevard frontage. The table below summarizes the unit composition for both the 3-story walk-ups and the 4-story wrap building. UNIT SUMMARY Residential Unit Type 3-Story Walk-Up 4-Story Wrap Total -Studio 84 units 33 units 117 units -1 Bedroom 153 units 194 units 347 units -2 Bedroom 86 units 121 units 207 units TOTAL 323 units 348 units 671 units Commercial -Commercial (SF) N/A 20,841 20,841 D. Recreation Amenities: The project provides 10 active residential amenities. Resident amenities include two pool/spa areas, an indoor gym, a community multi-purpose room with kitchen, an enclosed dog park with separate areas for small and large dogs, an observation deck, outdoor exercise area, outdoor gaming area, eight BBQ grill areas, and an enclosed children’s play area (Exhibit E – Overall Landscape Plan and Amenity Details). E. Fencing and Access: Most of the project site is ungated and is therefore publicly accessible by foot or by car. Vehicular entrances and sidewalks to the project’s two interior streets from Church Street, Foothill Boulevard, Elm Avenue, and Milliken Avenue are ungated. There are three pedestrian gates/fences that control access to the two clubhouse/pool areas and the fitness courtyard within the wrap building. The only vehicular gate on the property is utilized to separate the upper levels of the wrap building parking structure that is designated for residents from the first story of the parking structure that is primarily dedicated to commercial uses (Exhibit F – Wall and Fence Plan). F. Master Plan and Proposed Development Standards: One of the objectives of a Master Plan is to allow for the coordinated comprehensive planning of a subarea of the city in order to allow the development of an exceptional project design that cannot be built under an existing zoning district or due to constraints of existing development standards. The project includes a Master Plan application (Master Plan 2022-00074) Page 4 of 7 which proposes a site-specific set of development standards (Exhibit G – Harvest at Terra Vista Master Plan). These standards are meant to accommodate a well-balanced, functional, and highly walkable public realm within and around the project. The master plan is also intended to enable the development of two primary building types (3-story walk-ups and the 4-story wrap building). The table below lists the development standards proposed with Master Plan Master Plan 2022-00074. PROPOSED SITE-SPECIFIC DEVELOPMENT STANDARDS Development Standard Proposed Density (dwelling units/acre) 36 DU/AC Front Setback1 - Foothill Boulevard 0’ to 23’ Front Setback1 – Milliken Avenue 12’ to 20’ Front Setback1 – Church Street 15’ to 23’ Front Setback1 – Elm Avenue 10’ to 15’ Front Setback1 - Interior Streets (Applicable to all building frontages facing interior streets) 5’ to 7’ Interior Setback (West property line facing adjacent shopping center) 124’ Interior Setback (South property line facing adjacent shopping center) 56’ Distance Between Buildings Per Building Code Building Height – Walk-Ups 3 Stories Building Height – Wrap Building 4 Stories Landscape Area (Overall net area) Min. 10% Open Space Min. 150 SF/unit (100,650 SF) Parking RCMC Chapter 17.64 (see below) 1 – Measured from Property Line. For interior streets, property line is generally at the inside edge of the adjacent sidewalk (public right-of-way) G. Walkability: The project provides a complete pedestrian network, with sidewalks provided on both sides of all interior streets and along the project perimeter. Sidewalks along the interior streets are proposed to be 5 feet in width, while sidewalks along the project perimeter adjacent to public streets are 8 to 10 feet wide, allowing adequate space for pedestrian activity (Exhibit H – Walkway Circulation Plan). The proposed pedestrian routes are dotted with linear parks, seating areas, and landscaping, and uninterrupted by blank expanses or parking lots, resulting in an attractive walking environment. All front facades and building entrances are oriented towards streets/sidewalks, helping create a safe and active streetscape. H. Parking: The project’s master plan is designed to mirror the City’s current parking requirements as described in Section 17.64 of the Development Code. Based on all proposed uses on site, the project is required to provide 1,468 parking stalls, 671 of which are required to be in a garage or carport. Required parking includes tenant and visitor parking for the residential portion of the project, as well as parking for all commercial spaces. The project provides 1,468 parking stalls, 942 of which are covered, meeting the parking requirement (Exhibit I – Parking Plan). In order to ensure that on-site parking is properly managed, the applicant has provided a Parking Management Plan (Exhibit J – Parking Management Plan). This Parking Management Plan outlines how residential, guest, and commercial parking spaces are assigned, and details enforcement actions that apartment management can take in response to any potential parking violations. The following parking analysis table provides a breakdown of the required and provided parking spaces on-site. PARKING ANALYSIS Number of Units Square Footage Parking Ratio Required Parking Page 5 of 7 Multi-Family unit (studio) 117 N/A 1.3 per unit (1 in garage or carport) 152 Multi-family unit (One bedroom) 347 N/A 1.5 per unit (1 in garage or carport) 521 Multi-family unit (Two bedrooms) 207 N/A 2 per unit (1 in garage or carport) 414 Visitor parking 671 N/A 1 per 3 units 224 Commercial (Retail) N/A 8,590 4 per 1000 square feet 34 Commercial (Restaurant) N/A 12,251 10 per 1000 square feet 123 Total Parking Spaces Required 1,468 Total Parking Spaces Provided 1,468 Total Covered Parking Spaces Required/Provided 671/942 I. Tentative Map: The project includes the subdivision of the project site into four (4) numbered lots for condominium purposes, for the development of 671 apartments and 20,841 square feet of commercial space (Exhibit K – Tentative Map 20120). Each lot will help facilitate construction, circulation, and other components of the project. J. Public Art: This project is required to provide public art as outlined in Chapter 17.124 of the Development Code. Based on the number of residential units and commercial square footage for this project, the total art value required per Section 17.124.020.C. is $524,091. A condition has been included pursuant to the Development Code that requires the public art requirement to be met prior to occupancy. K. Design Review Committee: The project was reviewed by the Design Review Committee (Williams, Morales) on March 15, 2022. The Committee recommended approval of the project to the full Planning Commission. This is reflected in the in the Design Review Committee Comments (Exhibit L – DRC Minutes dated March 15, 2022). L. General Plan Consistency: The General Plan designations are centered around four primary components: Land Use and Development Intensity, Built Form and Character, Access and Connectivity, and Parks and Open Space. The project is located in the Corridor High designation of the General Plan, which is intended to provide for medium to high intensity developments along Foothill Boulevard that include a range of amenities, conveniences, housing options, and more at the edges of many existing and future neighborhoods. The project has been well-designed to align with the Corridor High designation. The project proposes a density of 39 units per acre, which falls within the expected range of the Corridor High designation of 36-60 units per acre. The proposed site plan includes proper building placement near the sidewalks with proper orientation to exterior or interior streets to accommodate active frontages and ground floor uses. The strategic placement of the buildings forms strong circulation patterns and streetscapes, helping create the desired urban character of the Corridor. The project site also has the benefit of street frontage on four sides and has taken advantage of those frontages to provide easy access and strong connectivity. The site is divided into quadrants, using privately owned streets to create walkable blocks in and throughout the project site. While the streets are privately owned, they will be public accessible and designed to look, feel, and function like public streets, as envisioned by the General Plan. CEQA DETERMINATION: The City of Rancho Cucamonga adopted a comprehensive update to the City’s General Plan (GPU) and certified a Program Environmental Impact Report (EIR) (SCH No. 2021050261) on December 15, 2021. As part of the Page 6 of 7 GPU, the Project site was designated for “City Corridor – High” land uses, which allows for residential development at densities ranging from 36 to 60 dwelling units per acre (du/ac) and non-residential development at a Floor Area Ratio (FAR) ranging from 0.6 to 1.5. According to Section 15168 of the CEQA Guidelines, a Program EIR may be prepared on a series of actions that can be characterized as one large project. Use of a Program EIR gives the Lead Agency an opportunity to consider broad policy alternatives and program-wide mitigation measures, as well as greater flexibility to address project-specific and cumulative environmental impacts on a comprehensive scale. Pursuant to Section 15183(c) of the State CEQA Guidelines, “if an impact is not peculiar to the parcel or to the project, has been addressed as a significant effect in the prior EIR, or can be substantially mitigated by the imposition of uniformly applied development policies or standards…then an additional EIR need not be prepared for the project solely on the basis of that impact.” The 17.2-acre property is designated by the City’s General Plan for “City Corridor – High” land uses. The GPU EIR assumed the Project site would be developed with 722 multi-family residential dwelling units and 337,154 square feet of commercial retail land uses. The proposed Project is fully consistent with the site’s GPU land use designation of “City Corridor – High” and would be consistent with all applicable GPU policies. Therefore, no subsequent or supplemental EIR is required for the proposed project. To demonstrate that no subsequent EIR or environmental review is required, a CEQA Section 15183 Compliance Memorandum dated March 22, 2022, was prepared by T & B Planning (Exhibit M – CEQA Section 15183 Compliance Memorandum). Staff evaluated this memorandum and concluded that the project is within the scope of the EIR adopted and certified as part of the City’s GPU on December 15, 2021. The project will not have one or more significant effects not discussed in the GPU EIR, nor have more severe effects than previously analyzed, and that additional or different mitigation measures are not required to reduce the impacts of the project to a level of less than significant. CORRESPONDENCE: This item was advertised as a public hearing with a regular legal advertisement in the Inland Valley Daily Bulletin newspaper, the property was posted, and notices were mailed to all property owners within a 660-foot radius of the project site. To date, no written correspondence, phone calls, or in person inquiries have been received regarding the project notifications. COUNCIL MISSION / VISION / GOAL(S) ADDRESSED: It is the City Council’s vision to make Foothill Boulevard the City’s mixed-use corridor, featuring a variety of urban developments that will enable a vibrant, walkable neighborhood that residents, workers, and visitors can enjoy. The proposed mixed-use development fits in this vision by developing a block of this mixed-use corridor. EXHIBITS: Exhibit A - Aerial Exhibit B - Detailed Site and Landscape Plan Exhibit C - Elevations, Unit Plans, and Renderings Exhibit D - Partial Foothill Elevation Exhibit E - Overall Landscape Plan and Amenity Details Exhibit F - Wall and Fence Plan Exhibit G - Harvest at Terra Vista Master Plan Exhibit H - Walkway Circulation Plan Exhibit I - Parking Plan Exhibit J - Parking Management Plan Exhibit K - Tentative Map 20120 Exhibit L - Draft DRC Minutes dated March 15, 2022 Exhibit M - CEQA Section 15183 Compliance Memorandum Page 7 of 7 Exhibit N - Draft Resolutions of Approval 22-12 TTM Harvest Exhibit O - Draft Resolutions of Approval 22-11 DR Harvest Exhibit P - Draft Resolutions of Approval 22-10 MP Harvest Exhibit Q - Conditions of Approval Exhibit R - Statement of Agreement CHURCH STREETFOOTHILL BOULEVARDELM STREET MILLIKENAVENUE600' 6 0 0 '600'600'600'BASEPOINTBASEPOINTGAR. 01 / A2KP KPKPKPKPKP GAR. 03 / B1BASEPOINTKP UP18RGAR. 03 / B1BASE POIN T KPKPKP KPUP18R KP KP KP KP KP KP KPKP KPKP KPKP KP KPKP KPKPKPKPKPKPKP KPKPKPKP KP KP KP KP KP KPKPKP KP KP KPKP KPKPKPKPKPKPKPKPKPKPKPKP KPKPKPKPKP KP KP KP KP KP KPKP KP KP KP KP KP KPKPKPKPKPKPKPKPKPKPKPKPKPKPKPUP18RKPKPKPKPKPKPKPKPKPKPKPKPKPKPUP18R UP18RS S/CBASEPOINT ELECTRICAL MAINSERVICEGAR. 06MPOEKP KPKPELECTRICALKPKPKPKPKPKPKP KP KPKP UP18RFIRERISER UP18RKPKPKPKPKPKPKPKPKPKPKPKPKPKPUP18 R UP18 R SS/CBASEPOINTELECTRICAL MAINSERVICEGAR. 06MPOE KP KP KP ELECTRICAL KP KP KP KPKP KPKPKPKPKP UP18RFIRERISER UP18 R KP KP KP KP KP KP KP KP KP KP KP KP KP KPUP18RUP18RKPKPKPKPKPKPKPKP KP KP KPKPKPKPUP18RUP18 R KP KP KPKPKPKP KP KP KP KP KP KP KP KP UP18RBASEPOINTBASEPOINTGAR. 01 / A2KPKPKPKPKPKPGAR. 03 / B1BASEPOINTKPKPKPKP UP18RGAR. 03 / B1BASEPOINT KP KP KP KPUP18R KP KP KP BASEPOINT BASEPOINT GAR. 01 / A2KPKP KPKPKPKPGAR. 03 / B1 BASEPOINT KPKPKPKPUP18R GAR. 03 / B1 BASEPOINTKPKP KPKPUP18RKPKPKPBASEPOINTBASEPOINTGAR. 01 / A2KP KP KPKPKP KP GAR. 03 / B1BASEPOINTKP KP KP KP UP18RGAR. 03 / B1BASEPOIN T KP KP KP KPUP18 R KP KP KP222PRINTER222PRINTER22PRINTER22PRINTER22KP KP KP KP KP KP KP KP KP KPKPKPKPKPKPKPKPKPKP KPKPKPUP18 R SS/C KP KP KP KP KP KP KP KP KP KP UP18RKPKPDUMPSTERBY OTHERSA(TRASH)DUMPSTERBY OTHERSA(TRASH)KPDUMPSTERBY OTHERSA(TRASH)KPKPKPKPKPKPKPKPKPKPKPKPKPKPKPKPKPKP KP KP KPKP KP KP KP KP KP KP KP KPKPKPKPKPKPKPKPKPKPKP KPKP KP KP KP KPKP KP UP UP5' DIA.5' DIA.3.1% RAMP UP 1.6% RAMP UP4.6% RAMP DN 4.0% RAMP UP @ 247' = 10'-0"1234567891011121314151617181920212223242526272829303132333435363738394012345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485UP30"2449 30"244930"2449 30"24 4930"24 49 30"24 49 30"24 49 30"2449 30"24494.8%7.2%30"24 49 30"244908.67 TC08.00 FLIN THE CITY OF RANCHO CUCAMONGA, COUNTY OF SAN BERNARDINOSTATE OF CALIFORNIAJANUARY 10, 202217.29 AC. GROSS TENTATIVE TRACT NO. 2012017.29 AC. NETAPN: 1077-422-51,52,54,55 AND 1090-121-284 NUMBERED LOTS(198 UNITS FOR CONDOMINIUM PURPOSES)SITE UTILIZATION MAP SUM-01WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEMADOLE&ASSOCIATES, INC.RANCHO CUCAMONGA, CALIFORNIAHARVEST AT TERRA VISTADATE: JANUARY 10, 2022JOB NO. 126-2647CIVIL ENGINEEROWNER/DEVELOPERMADOLE & ASSOCIATES, INC.CONSULTING CIVIL ENGINEERS,PLANNERS AND SURVEYORS9302 PITTSBURGH AVENUE, SUITE 230RANCHO CUCAMONGA, CA 91730CONTACT: MARK BERTONE(909) 481-6322 ext. 120Email: mbertone@madoleinc.comAO ARCHITECTS144 NORTH ORANGE STORANGE, CA 92866CONTACT: IOANNA MAGIATI (714) 639-9860Email:ioannam@aoarchitects.com1156 N. MOUNTAIN AVEUPLAND, CA. 91786CONTACT: BRIAN JACOBSON(909) 579-1214 OFFICEEmail: Brian.Jacobson@lewismc.comARCHITECTSITESCAPES, INC.3190 B-2 AIRPORT LOOP DRIVECOSTA MESA, CA. 92626CONTACT: RICK POLHAMUS(949) 644-9370Email: rpolhamus@sitescapes.netLANDSCAPE ARCHITECTWDCC MILLIKEN WEST RESIDENTIAL, LLCNTSVICINITY MAPMILLIKEN CHURCHMAYTEN PROJECT LOCATIONELM FOOTHILLSTREETAVENUE AVENUEEUCALYPTUSSTREET AVENUEBOULEVARDSPRUCE AVENUE J:\126-2647\tentative\SUM.dwg, 1/10/2022 10:59:04 AM, dmartinezExhibit A 22'-0"FITNESSCO-WORKBREEZEWAYENTRYFITNESSELECTRICAL\MPOELEASINGENTRY23'-6" 12'-1" T.O. PLATE 124789612'-1" T.O. PLATECO-WORKENTERTAINMENTENTERTAINMENTLEASING20'-3" 23'-6 1/2" 22'-0" 12'-1" T.O. PLATE 12'-1" T.O. PLATE 48"22"BREEZWAYFITNESS30'-0" X 58'-6"YOGA30'-0" X 17'-0"CO-WORK20'-6" X 27'-4"MPOE/ITJANITORLEASING25'-0" X 32'-0"MAINTENANCE/STORAGERESTROOMOFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"BREAK RM.11'-0" X 16'-0"ENTERTAINMENT44'-0" X 23'-0"CONF.17'-0" X 13'-6"CONF.10'-0" X 13'-6"MENWOMEN5'-0"PORCH19'-0" X 22'-0"ELEC.2,515 SQ. FT.3,018 SQ. FT.1,532 SQ. FT.1,000 SQ. FT.1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA1.0CLUBHOUSE - ELEVATIONS1/8"=1'-0"24'08'4'16'EAST ELEVATIONSOUTH ELEVATIONWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283WEST ELEVATIONNORTH ELEVATIONWESTSOUTH EASTNORTHExhibit C 48"22"BREEZWAYFITNESS30'-0" X 58'-6"YOGA30'-0" X 17'-0"CO-WORK20'-6" X 27'-4"MPOE/ITJANITORLEASING25'-0" X 32'-0"MAINTENANCE/STORAGERESTROOMOFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"BREAK RM.11'-0" X 16'-0"ENTERTAINMENT44'-0" X 23'-0"CONF.17'-0" X 13'-6"CONF.10'-0" X 13'-6"MENWOMEN5'-0"PORCH19'-0" X 22'-0"ELEC.2,515 SQ. FT.3,018 SQ. FT.1,532 SQ. FT.1,000 SQ. FT.A1.1CLUBHOUSE - RENDERINGSWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2833FITNESS CORNER4LEASING CORNER2COVERED WALKWAYP 4 1ENTRYP3P2P1 48"22"BREEZWAYFITNESS30'-0" X 58'-6"YOGA30'-0" X 17'-0"CO-WORK20'-6" X 27'-4"MPOE/ITJANITORLEASING25'-0" X 32'-0"MAINTENANCE/STORAGERESTROOMOFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"BREAK RM.11'-0" X 16'-0"ENTERTAINMENT44'-0" X 23'-0"CONF.17'-0" X 13'-6"CONF.10'-0" X 13'-6"MENWOMENPORCH19'-0" X 22'-0"ELEC.2,515 SQ. FT.3,018 SQ. FT.1,532 SQ. FT.1,000 SQ. FT.POOL EQUIP.10'-0" X 15'-0"WCDOG WASHWCSHOWERSA1.2CLUBHOUSE - GROUND FLOOR PLAN NORTHWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16' A1.3CLUBHOUSE - ROOF PLAN NORTHWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16' ± 40'-6" TOTOP OF ROOF3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"9'-1"123457968629'-3" 3RD STORYT.O. PLATE± 38'-6" TOTOP OF ROOF± 40'-6" TOTOP OF ROOFUP18RSSSKP KP KP KPKPKPUP18R S FIRERISERKP KP KP KP KP KP KP 4:12PER FOOT 4:12PER FOOT 4:12PER FOOT 4:12PER FOOT 4:12PER FOOT 4:12PER FOOT 4:12PER FOOT± 40'-6" TOTOP OF ROOF3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"9'-1"± 40'-6" TOTOP OF ROOF± 38'-6" TOTOP OF ROOF29'-3" 3RD STORYT.O. PLATE1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA2.0ELEVATIONS - 20 PLEXLEFTFRONTRIGHTREARFRONT ELEVATION1/8"=1'-0"24'08'4'16'P2P1REAR ELEVATIONLEFT ELEVATIONRIGHT ELEVATIONFRONTREARWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2833-STORY WALK-UPLOCATION OF ART** A3S1A2S2488 SF682 SF615 SF824 SFLEVEL 1121'-0"64'-1"MPOE ELECTRIALFIRERISER UP18RSS/CSELECTRICAL MAINSERVICEMPOE KPKPKPELECTRICAL KPKPKPUP18RFIRERISERKP KP KP KP KP KP KP4:12PER FOOT 4:12PER FOOT4:12 PER FOOT 4:12 PER FOOT 4:12 PER FOOT 4:12PER FOOT 4:12PER FOOT8'-1"11'-4"11'-7"10'-8" 26'-11"11'-0"8'-8"11'-0"5'-0"10'-10"12'-0"11'-0"13'-6"11'-2"12'-4"15'-7"8'-9"4'-9"6'-5"9'-4"15'-10"14'-2"9'-3"10'-5"9'-3"19'-5"121'-0"B1A3A3S1A2S2A1488 SF824 SFLEVEL 2824 SF615 SF682 SFB11,008 SF744 SFB11,008 SFSSS/CSSSUP18RDN18RUP18RDN18R4:12PER FOOT4:12PER FOOT 4:12PER FOOT4:12PER FOOT4:12 PER FOOT 4:12 PER FOOT 4:12 PER FOOT 4:12 PER FOOT 4:12PER FOOT4:12PER FOOT 4:12 PER FOOT 4:12 PER FOOT 4:12PER FOOT63'-9" 12'-0"11'-0"12'-2"17'-5" 5'-4"6'-6"8'-0"11'-11"9'-6"12'-6"10'-8"7'-9"8'-3"11'-9"17'-5"6'-4"11'-0"12'-0" 8'-1"11'-4"11'-7"10'-8" 26'-11"11'-0"8'-8"11'-0"5'-0"10'-10"12'-0"11'-0"13'-6"11'-2"12'-4"15'-7"8'-9"4'-9"6'-5"9'-4"15'-10"14'-2"9'-3"10'-5"9'-3"19'-5"1/8"=1'-0"24'08'4'16'A2.1 BUILDING PLANS - 20 PLEXWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2833-STORY WALK-UPSTORAGE (125 CUBIC FEET PER 1 DWELLING UNIT) B1B1A3A3S1A2S2A11,008 SFLEVEL 3B1488 SF824 SF824 SF615 SF682 SF1,008 SF744 SFSDN18RSS/CSSSDN18R3:12PER FOOT3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT 121'-0"63'-9"122'-4"66'-2"ROOF3:12PER FOOT3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT1'-0"TYP.1/4:12PER FOOT, TYP.10'-6" 12'-3"T.O.P.=+5'-9"T.O.P.=+5'-9"1'-0"TYP.1/4:12PER FOOT, TYP.HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6" HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"ROOFTOP MECHANICAL EQUIPMENTCONCEALED FROM EXTERIOR VIEWBY PERIMETER PARAPET WALLS (TYP.)AC UNIT1/8"=1'-0"24'08'4'16'3-STORY WALK-UPA2.2BUILDING PLANS - 20 PLEX 3-STORY WALK-UPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283MECHANICAL EQUIPMENT SCREENING UP18RSSSSKPKPKP KP KP KP UP18RS SDS/CFIRE RISER KP KP KP KP KP KP KP KP 3:12PER FOOT 3:12PER FOOT3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"9'-1"123457896± 41'-9" TOTOP OF ROOF29'-3" 3RD STORYT.O. PLATE± 38'-6" TOTOP OF ROOF3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"9'-1"± 41'-9" TOTOP OF ROOF29'-3" 3RD STORYT.O. PLATE± 38'-6" TOTOP OF ROOF± 37'-10" TOTOP OF ROOF± 40'-5" TOTOP OF ROOF± 42'-0" TOTOP OF ROOF1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA2.3ELEVATIONS - 23 PLEX1/8"=1'-0"24'08'4'16'LEFTFRONTRIGHTREARP2P1FRONT ELEVATIONREAR ELEVATIONLEFT ELEVATIONRIGHT ELEVATIONFRONTREARWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2833-STORY WALK-UPLOCATION OF ART** 138'-0"UP18RSSKPKPKPELECTRICAL MAINSERVICEMPOE KPKPKPELECTRICAL UP18RFIRE RISER KP KP KP KP KP KP KP KP 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12PER FOOT 3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 61'-3" 8'-1"11'-4"11'-7"10'-8"26'-11"11'-0"12'-0"11'-0"8'-8"11'-0"13'-6"11'-2"12'-4"15'-7"8'-9"4'-9"6'-5"9'-4"5'-0"10'-10"138'-6"SSSSSUP18RDN18RUP18RDN18R3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT 3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT3:12PER FOOT63'-9" 10'-1"11'-4"11'-7"10'-8"26'-11"11'-0"12'-0"11'-0"8'-8"11'-0"13'-6"11'-2"12'-4"15'-7"8'-9"4'-9"12'-6"10'-8"7'-9"8'-3"11'-9"17'-5"6'-4"11'-0"12'-0"6'-5"9'-4"5'-0"10'-10"1/8"=1'-0"24'08'4'16'3-STORY WALK-UPA2.4 BUILDING PLANS - 23 PLEX3-STORY WALK-UPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283STORAGE (125 CUBIC FEET PER 1 DWELLING UNIT) 138'-6"DN18RDN18RSSSSS3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT63'-9"140'-6"3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT 10'-0"7:12SLOPE, TYP.1'-0"TYP.10'-0"2'-0"7'-2"6'-0" 1'-0" TYP. 2'-0"T.O.P.=+5'-9"T.O.P.=+3'-9"T.O.P.=+5'-9"T.O.P.=+3'-9"T.O.P.=+5'-9"T.O.P.=+3'-9"T.O.P.=+3'-9"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6" HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"10'-0"4'-6" 66'-2"ROOFTOP MECHANICAL EQUIPMENTCONCEALED FROM EXTERIOR VIEWBY PERIMETER PARAPET WALLS (TYP.)AC UNIT1/8"=1'-0"24'08'4'16'3-STORY WALK-UPA2.5BUILDING PLANS - 23 PLEX 3-STORY WALK-UPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283MECHANICAL EQUIPMENT SCREENING SSSSSSUP18RUP18RS S SD S/CSKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3:12PER FOOT 3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"9'-1"1234567896± 40'-9" TOTOP OF ROOF29'-3" 3RD STORYT.O. PLATE± 37'-9" TOTOP OF ROOF3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"9'-1"± 40'-9" TOTOP OF ROOF29'-3" 3RD STORYT.O. PLATE± 37'-3" TOTOP OF ROOF1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA2.6ELEVATIONS - 37 PLEX1/8"=1'-0"24'08'4'16'LEFTFRONTRIGHTREARP2P1WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283FRONTREARFRONT ELEVATIONLEFT ELEVATIONREAR ELEVATIONRIGHT ELEVATION3-STORY WALK-UP 210'-6"SSSELECTRICAL MAIN SERVICE ELECTRICALUP18R UP18RSKPKPKPKPKPKP KP KP KP KP KP KP KP KP KP KP KP 3:12PER FOOT 3:12PER FOOT3:12PER FOOT3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT61'-3"9'-1"11'-4"11'-7"10'-8"26'-11"11'-0"12'-0"11'-0"8'-8"11'-0"13'-6"11'-2"12'-4"8'-9"4'-9"6'-4"9'-4"13'-0"11'-0"12'-2"22'-6" 7'-8"9'-7"11'-6"14'-0" 11'-1" 6'-11" 13'-1" 15'-0"210'-6"SSSSSSSSUP18RDN18RSUP18RDN18R3:12PER FOOT3:12PER FOOT3:12PER FOOT3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT63'-9"9'-1"11'-4"11'-7"10'-8"26'-11"11'-0"12'-0"11'-0"13'-6"11'-2"12'-4"8'-9"4'-9"6'-4"9'-4"13'-0"11'-0"22'-6" 7'-8"9'-7"11'-6"14'-0" 11'-1" 6'-11" 13'-1" 15'-0" 7'-0" 8'-8"11'-0"4'-1"4'-3"12'-6"10'-8"7'-9"8'-3"11'-9"17'-5"6'-4"11'-0"12'-0" 12'-0"11'-0"12'-2"17'-5" 5'-4"6'-6"8'-0"11'-11"9'-6"1/8"=1'-0"24'08'4'16'3-STORY WALK-UPA2.7BUILDING PLANS - 37 PLEX 3-STORY WALK-UPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283STORAGE (125 CUBIC FEET PER 1 DWELLING UNIT) 210'-6"DN18RSSSSSSSSSDN18RS3:12PER FOOT3:12PER FOOT3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT63'-9"212'-6"3:12PER FOOT3:12PER FOOT3:12PER FOOT3:12PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12 PER FOOT 3:12PER FOOT3:12PER FOOT7'-6" 17'-6"7'-0"T.O.P.=+5'-9"1'-0" TYP. 1'-0"TYP.15'-0"T.O.P.=+5'-9"T.O.P.=+5'-9"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6" HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"HEEL HEIGHT = 2'-6"T.O.P.=+5'-9"66'-1"ROOFTOP MECHANICAL EQUIPMENTCONCEALED FROM EXTERIOR VIEWBY PERIMETER PARAPET WALLS (TYP.)AC UNIT1/8"=1'-0"24'08'4'16'3-STORY WALK-UPA2.8BUILDING PLANS - 37 PLEX 3-STORY WALK-UPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283MECHANICAL EQUIPMENT SCREENING UNIT S1 (FLOORS 1-3 ADA)STUDIO - 1 BATHNET LIVABLE: 488 SQ. FT.PATIO/DECK : 69 SQ. FT.21'-3"36'-2"LIVINGROOM11'-6"x8'-7"FLEXDININGKITCHENBATHW/DSLEEPING9'-2"x8'-6"PATIO11'-6"x6'-11"ENTRY6'-11"REFPCB36"x60" Q4'-3"CBCBUNIT A2 (FLOORS 1-3 - ADA)1 BDRM - 1 BATHNET LIVABLE: 682 SQ. FT.PATIO/DECK : 73 SQ. FT.23'-5"36'-2"BEDROOM11'-6"x11'LIVINGROOM11'-0"x16'-6"PATIO11'-0"x7'-4"KITCHENW/DLBATHENTRYCB 7'-4"36"x 60" PREFDININGROOM5'-2"QUNIT A1 (UPPER FLOORS - NON-ADA)1 BDRM - 1 BATHNET LIVABLE: 744 SQ. FT.BALCONY : 44 SQ. FT.32'-6"24'-10"LIVINGROOM12'-2"x15'-2"BEDROOM11'-0"x12'-0"BALCONY8'-0"x5-4"FLEX8'-0"x8'-4"ENTRYBATHW.I.C.KITCHENREFPDKW36"x60" 5MdfSHLVS FURNITURELIVINGROOM11'-8"x15'-2"BEDROOM11'-0"x12'-0"BEDROOM11'-0"x12'-6"BALCONY7'-10"x5'-2"KITCHENFLEXDINING8'-0"x8'-4"ENTRYW.I.C.PUNIT B1 (UPPER FLOORS NON-ADA)2 BDRM - 2 BATHNET LIVABLE: 1008 SQ. FT.PATIO/DECK : 53 SQ. FT.43'-4"24'-10"DBATHBATHREFW.I.C.Q36" x 60"KW36" x 60"5MdfSHLVSBUILT-INISLANDENTRYCBCBKITCHEN PLIVINGROOM12'-2"x12'-6"PATIO11'-4"x6'-6"BEDROOM11'-6"x13'-0"BATHW.I.C.W/DBATHBEDROOM11'-0"x12'-6"UNIT B2 (FIRST FLOOR - ADA)2 BDRM - 2 BATHNET LIVABLE: 1,128 SQ. FT.PATIO/DECK : 92 SQ. FT.35'-10"36'-8"DININGROOM36" x 60"LLREFW.I.CBUILD OUTON FIRSTFLOOR ONLYKQBUILT-IN ISLAND 36" x 60"UNIT S2 (FIRST FLOOR - ADA)STUDIO - 1 BATHNET LIVABLE: 615 SQ. FT.17'-0"36'-2"LIVINGROOM13'-8"x15'-8"BATHENTRYW/DSLEEPING8'-10"x9'-4"CLOSET KITCHENREFPLINENQ3'-6"36"x60" UNIT A3 (FIRST FLOOR - ADA)1 BDRM - 1 BATHNET LIVABLE: 824 SQ. FT.PATIO : 126 SQ. FT.24'-4"40'-6"BEDROOM11'-0"x12'-0"PATIO12'-1"x10'-5"KITCHENLIVINGROOM13'-6"x12'-3"DININGROOMW.I.C.ENTRYREFK23'-4"LPCOATSBATHW/D L36"x60" CBCB BUILT-INDESKA3.0UNIT PLANS3/16"=1'-0"4' 8' 16'0 2'1'3-STORY WALK-UPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283 KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KPKPKP KP KP KP KPKPKP KP KP UP18R KP KP KPKP KP KP KP KP KP KP KP KP KP KP UP18R UP18R SS/CKP KP KP KP KP KP KP KP KP KP KP KP KP UP18R UP18RKP KP KP KPKPKP KP KP KP KP KP KP KP KP UP18R UP18R S S/C KP KP KP KP KP KP KP KP KP KP KPKPKP UP18R UP18R KP KP KP KP KP KP KP KP KP KP KP KP KP KP UP18R UP18R KPKPKP KP KP KP KPKPKP KP KP KP KP KPUP18R UP18R KP KP KP KP KP KP KP KP KPKP KP KP KP KP UP18RKPKPKPKPKPKPKPKPKPKP UP18R KP KP KP KP UP18R KP KP KP KP KP KP KP KP KP KP KP KP KP UP18RKPKP KP KP UP18R KP KP KP KP KP KP KP KP KP KP KP KPKP UP18R KPKP KP KP UP18R KP KPKP KP KP KP KP KP KP KP KP KPKPUP 18RKP KP KP KP UP18R KP KP KP 2 22 PRINTER22 2 PRINTER 22 PRINTER 2 2 PRINTER2 2 KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KPKP KP KPKPKP UP18R SS/CKP KP KP KP KP KP KP KP KP KP UP18RKPKPDUMPSTERBY OTHERSA(TRASH)DUMPSTERBY OTHERSA(TRASH) KPDUMPSTERBY OTHERSA(TRASH) KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP UP UP 5' DIA.5' DIA.END OFLOWER LEVGATEUP30"24 49 30"24 49 30"24 49 30"24 49 30"24 49 OPEN OPENOPEN 30"24 49 30"24 49 30"2449 30"2449 4.8%7.2% 30"24 49 30"2449F O O T H I L L B L V D .M I L L I K E N A V E .E L M A V E .C H U R C H S T .C H U R C H S T .M I L L I K E N A V E .F O O T H I L L B L V D .123456789121110G-2G-3G-4G-1G-6G-5G-7B-1237-PLEXB-1123-PLEXB-1037-PLEXB-720-PLEXB-623-PLEXB-320-PLEXB-423-PLEXB-837-PLEXB-923-PLEXB-137-PLEXB-223-PLEXB-520-PLEXA4.03-STORY WALK-UP - PERSPECTIVEWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-19-22JOB NO.: 2019-283CORNER OF CHURCH AND ELMELM AVENUE KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KPKPKP KP KP KP KPKPKP KP KP UP18R KP KP KPKP KP KP KP KP KP KP KP KP KP KP UP18R UP18R S S/CKP KP KP KP KP KP KP KP KP KP KP KP KP UP18R UP18RKP KP KP KPKPKP KP KP KP KP KP KP KP KP UP18R UP18R S S/C KP KP KP KP KP KP KP KP KP KP KPKP KP UP18R UP18R KP KP KP KP KP KP KP KP KP KP KP KP KP KP UP18R UP18R KPKPKP KP KP KP KPKPKP KP KP KP KP KPUP18R UP18R KP KP KP KP KP KP KP KP KPKP KP KP KP KP UP18RKPKPKPKPKPKPKPKPKPKP UP18R KP KP KP KP UP18R KP KP KP KP KP KP KP KP KP KP KP KP KP UP18RKPKP KP KP UP18R KP KP KP KP KP KP KP KP KP KP KP KPKP UP18R KPKP KP KP UP18R KP KPKP KP KP KP KP KP KP KP KP KPKPUP18RKP KP KP KP UP18R KP KP KP 2 2 2 PRINTER22 2 PRINTER 22 PRINTER 2 2 PRINTER2 2 KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KPKP KP KP KPKP UP18R SS/CKP KP KP KP KP KP KP KP KP KP UP18RKPKPDUMPSTERBY OTHERSA(TRASH)DUMPSTERBY OTHERSA(TRASH) KPDUMPSTERBY OTHERSA(TRASH) KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP UP UP 5' DIA.5' DIA.END OFLOWER LEVGATEUP30"24 49 30"24 49 30"24 49 30"24 49 30"24 49 OPEN OPENOPEN 30"24 49 30"24 49 30"24 4930"2449 4.8%7.2% 30"24 49 30"2449F O O T H I L L B L V D .M I L L I K E N A V E .E L M A V E .C H U R C H S T .C H U R C H S T .M I L L I K E N A V E .F O O T H I L L B L V D .123456789121110G-2G-3G-4G-1G-6G-5G-7B-1237-PLEXB-1123-PLEXB-1037-PLEXB-720-PLEXB-623-PLEXB-320-PLEXB-423-PLEXB-837-PLEXB-923-PLEXB-137-PLEXB-223-PLEXB-520-PLEXA4.13-STORY WALK-UP - PERSPECTIVEWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-19-22JOB NO.: 2019-283CHURCH STREET ENTRYCHURCH STREET KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KPKPKP KP KP KP KPKPKP KP KP UP18R KP KP KPKP KP KP KP KP KP KP KP KP KP KP UP18R UP18R S S/CKP KP KP KP KP KP KP KP KP KP KP KP KP UP18R UP18RKP KP KP KPKPKP KP KP KP KP KP KP KP KP UP18R UP18R S S/C KP KP KP KP KP KP KP KP KP KP KPKP KP UP18R UP18R KP KP KP KP KP KP KP KP KP KP KP KP KP KP UP18R UP18R KPKPKP KP KP KP KPKPKP KP KP KP KP KPUP18R UP18R KP KP KP KP KP KP KP KP KPKP KP KP KP KP UP18RKPKPKPKPKPKPKPKPKPKP UP18R KP KP KP KP UP18R KP KP KP KP KP KP KP KP KP KP KP KP KP UP18RKPKP KP KP UP18R KP KP KP KP KP KP KP KP KP KP KP KPKP UP18R KPKP KP KP UP18R KP KPKP KP KP KP KP KP KP KP KP KPKPUP18RKP KP KP KP UP18R KP KP KP 2 2 2 PRINTER22 2 PRINTER 22 PRINTER 2 2 PRINTER2 2 KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KPKP KP KP KPKP UP18R SS/CKP KP KP KP KP KP KP KP KP KP UP18RKPKPDUMPSTERBY OTHERSA(TRASH)DUMPSTERBY OTHERSA(TRASH) KPDUMPSTERBY OTHERSA(TRASH) KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKPKP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP UP UP 5' DIA.5' DIA.END OFLOWER LEVGATEUP30"24 49 30"24 49 30"24 49 30"24 49 30"24 49 OPEN OPENOPEN 30"24 49 30"24 49 30"24 4930"2449 4.8%7.2% 30"24 49 30"2449F O O T H I L L B L V D .M I L L I K E N A V E .E L M A V E .C H U R C H S T .C H U R C H S T .M I L L I K E N A V E .F O O T H I L L B L V D .123456789121110G-2G-3G-4G-1G-6G-5G-7B-1237-PLEXB-1123-PLEXB-1037-PLEXB-720-PLEXB-623-PLEXB-320-PLEXB-423-PLEXB-837-PLEXB-923-PLEXB-137-PLEXB-223-PLEXB-520-PLEXA4.23-STORY WALK-UP - PERSPECTIVEWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-19-22JOB NO.: 2019-283CORNER OF MILLIKEN AND CHURCHMILLIKEN AVENUE 1299'-1"T.O. PLATE9'-1"T.O. PLATE±20'-9"T.O. ROOF9'-1"T.O. PLATE±20'-9"T.O. ROOF±20'-9"T.O. ROOF1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEFRONT ELEVATIONRIGHT ELEVATIONLEFT ELEVATIONREAR ELEVATIONA5.0ELEVATION G-11/8"=1'-0"24'08'4'16'WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283STAND ALONE GARAGELOCATION OF ART** 9±16'-10"T.O. ROOF9'-1"T.O. PLATE±16'-10"T.O. ROOF9'-1"T.O. PLATE12±16'-10"T.O. ROOF9'-1"T.O. PLATE1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEFRONT ELEVATIONRIGHT ELEVATIONLEFT ELEVATIONREAR ELEVATIONA5.1ELEVATION G-2WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16'STAND ALONE GARAGE ±16'-10"T.O. ROOF9'-1"T.O. PLATE912±16'-10"T.O. ROOF9'-1"T.O. PLATE±16'-10"T.O. ROOF9'-1"T.O. PLATE1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA5.2ELEVATION G-3WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16'STAND ALONE GARAGEFRONT ELEVATIONRIGHT ELEVATIONLEFT ELEVATIONREAR ELEVATION 1299±16'-10"T.O. ROOF9'-1"T.O. PLATE±16'-10"T.O. ROOF9'-1"T.O. PLATE±16'-10"T.O. ROOF9'-1"T.O. PLATE1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA5.3ELEVATION G-4WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16'STAND ALONE GARAGEFRONT ELEVATIONRIGHT ELEVATIONLEFT ELEVATIONREAR ELEVATION ±16'-10"T.O. ROOF9'-1"T.O. PLATE±16'-10"T.O. ROOF9'-1"T.O. PLATE±16'-10"T.O. ROOF9'-1"T.O. PLATE2911. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA5.4ELEVATION G-5WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16'STAND ALONE GARAGEFRONT ELEVATIONRIGHT ELEVATIONLEFT ELEVATIONREAR ELEVATION ±16'-10"T.O. ROOF9'-1"T.O. PLATE29±16'-10"T.O. ROOF9'-1"T.O. PLATE±16'-10"T.O. ROOF9'-1"T.O. PLATE11. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA5.5ELEVATION G-6WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16'STAND ALONE GARAGEFRONT ELEVATIONRIGHT ELEVATIONLEFT ELEVATIONREAR ELEVATION 9'-1"T.O. PLATE129'-1"T.O. PLATE±13'-8"T.O. ROOF9'-1"T.O. PLATE±13'-8"T.O. ROOF±13'-8"T.O. ROOF91. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEA5.6ELEVATION G-7WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831/8"=1'-0"24'08'4'16'STAND ALONE GARAGEFRONT ELEVATIONRIGHT ELEVATIONLEFT ELEVATIONREAR ELEVATIONLOCATION OF ART** 12345678963RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE15'-0"9'-1"4TH STORYT.O. PLATE± 54'-2"TOP OF ROOF± 57'-3" TOT.O. FIN1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCE1SOUTH ELEVATION2SW CORNER PERSPECTIVE3SE CORNER PERSPECTIVEWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-19-22JOB NO.: 2019-2831WRAPB2.0ELEVATION - SOUTH1/16"=1'-0"16' 32' 48'0 8'23 12456789633RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"9'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE15'-0"9'-1"4TH STORYT.O. PLATE± 54'-2"TOP OF ROOF± 57'-3" TOT.O. FIN1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCE1WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283WRAPB2.1ELEVATION - SOUTH ENLARGEMENT1/8"=1'-0"24'08'4'16'1SOUTH ELEVATION2SOUTH ELEVATION2MATCH MATCHMATCH MATCH ROOF LOUNGEROOF LOUNGE123456789 3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"10'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE9'-1"12'-1"LOUNGET.O. PLATE± 51'-10"TOP OF ROOF1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCE1EAST ELEVATION1322NE CORNER PERSPECTIVE3EAST PERSPECTIVEROOF LOUNGEROOF LOUNGEWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283WRAPB2.2ELEVATION - EAST1/16"=1'-0"16' 32' 48'0 8' 123457891. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCE ROOF L O UN G E ROOF L O UN G E6 3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"10'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE9'-1"12'-1"LOUNGET.O. PLATE± 51'-10"TOP OF ROOFWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283WRAPB2.3ELEVATION - EAST ENLARGEMENT1/8"=1'-0"24'08'4'16'1EAST ELEVATION2EAST ELEVATION2MATCH MATCHMATCH MATCH1 1234567893RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE± 51'-0"TOP OF ROOF9'-1"9'-1"10'-11"4TH STORYT.O. PLATE± 53'-4"TOP OF PARAPET1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCE1NORTH ELEVATION2NE CORNER PERSPECTIVE3NW CORNER PERSPECTIVE132ROOF LOUNGEGARAGE ENTRYGARAGE ENTRYRESIDENT'S LOBBYRESIDENT'S LOBBYGARAGE ENTRYRESIDENT'S LOUNGEWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283WRAPB2.4ELEVATION - NORTH1/16"=1'-0"16' 32' 48'0 8' 1234567891. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCE3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE± 51'-0"TOP OF ROOF9'-1"9'-1"10'-11"4TH STORYT.O. PLATE± 53'-4"TOP OF PARAPETWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-2831WRAPB2.5ELEVATION - NORTH ENLARGEMENT1/8"=1'-0"24'08'4'16'21NORTH ELEVATION2NORTH ELEVATIONMATCH MATCHMATCH MATCH 1234567893RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE± 52'-3"TOP OF ROOF9'-1"9'-1"15'-0"4TH STORYT.O. PLATE± 57'-3"TOP OF PARAPET1. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCEB2.6 ELEVATIONS - WEST1WEST ELEVATION2NW CORNER PERSPECTIVE3SW CORNER PERSPECTIVE132RESIDENT'S LOUNGEGARAGE ENTRYGARAGE ENTRYGARAGE ENTRYRESIDENT'S LOUNGERESIDENT'S LOBBYRESIDENT'S LOBBYWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283WRAP1/16"=1'-0"16' 32' 48'0 8' 12456781. CONCRETE FLAT TILE2. STUCCO3. STUCCO TRIM4. VINYL WINDOW5. METAL GUARDRAIL6. METAL AWNING7. BOARD AND BATTEN8. COMPOSITE WOOD SIDING9. WALL SCONCE393RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE± 52'-3"TOP OF ROOF9'-1"9'-1"15'-0"4TH STORYT.O. PLATE± 57'-3"TOP OF PARAPETB2.7 ELEVATIONS - WEST1WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283WRAP1NORTH ELEVATION2NORTH ELEVATIONMATCH MATCHMATCH MATCH1/8"=1'-0"24'08'4'16'2 ELECTRICAL MAINSERVICE ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KP ELECTRICAL KP KP ELECTRICAL ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP UP18R KPKP KP KP S KP KP KP KP KP KP KP ELECTRICAL MAINSERVICE MPOEKPKPKPELECTRICAL UP18RFIRE RISER UP18R S S/CJ SS/C S ELECTRICAL MAINSERVICE MPOEKPKP KP ELECTRICAL KP KPKPKPKPKP KP KP KP KP UP18RSSDS/CFIRERISER UP18RKP KP KP KP S KP KP KP KP KP KP KP ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL UP18RFIRE RISER UP18R S S/C JSS/C SELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL KP KP KP KP KP KP KP KP KPKP UP18R S SD S/C FIRERISER UP18R KP KP KP KP SKP KP KP KP KP KP KP ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL UP18R FIRE RISER UP18R KPKP KP KP S KP KP KPKPKP KP KPELECTRICAL MAIN SERVICEMPOE KP KP KPELECTRICAL UP18R FIRE RISER UP18R KP KP KP KP SKP KP KP KP KPKP KP ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL UP18R FIRE RISER J SS/C SSPATIO JSS/CSPATIO J SS/C KPKPKPKPKPKP ELECT R IC A L MPOE FIRE RIS E R KPKPKPKP UP18R KP KP KP KP UP18R KP KP KP ELECT R IC A L M A IN S ER V IC E ELECTR I CA L S SD S/C S REF 3DP CB SD S/C S J S S/C S S PATIOJSS/CS PATIO J S S/C KPKPKP KP KP KP ELECTRICALMPOEFIRE RISER KP KPKPKP UP18RKPKPKP KP UP18R KPKP KP ELECTRICAL MAIN SERVICEELECTRICALS SDS/C SREF3DPCB SDS/CS J S S/C S S PATIO J SS/C S PATIOJ SS/C KP KP KPKP KP KP ELECTRICALMPOEFIRE RISER KP KP KPKPUP18R KPKPKP KP UP18RKP KP KP ELECTRICAL MAIN SERVICEELECTRICALSSDS/CS REF3DPCB SDS/CS J SS/C SSPATIOJS S/C S PATIO JS S/C KP KP KP KP KP KP ELECTRICALMPOEFIRE RISER KP KP KP KP UP18RKP KP KP KP UP18R KP KP KP ELECTRICAL MAIN SERVICE ELECTRICAL S SDS/C S REF3DP CBSD S/C S22 2 PRINTER 222 PRINTER 2 2 PRINTER22 PRINTER2 2BREEZW AYMPOE/IT JAN I TORMAINT ENA NC E/STORAGE RESTR OOM MEN WOMENELEC . ELECTRICAL ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPRTRTMAINT. RM. KP KP UP18R SS/C JSS/C S ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL KP KP KP KP KP KP KP UP18RS SD S/C FIRERISERKPKPDUMPSTERBY OTHERSA(TRASH)DUMPSTERBY OTHERSA(TRASH) KP DUMPSTERBY OTHERSA(TRASH) ELECTRICAL MAINSERVICEELECTRICALMPOE KP KP KP KP KP KP KP KP KPKPKPKPKPKPKPKPKP KP ELECTRICAL MAINSERVICEELECTRICAL MPOE KP KP KP KP KP KP KP KP KP KP KPKPKPKP KP KP KPKPKPKP KP KP KPKP ELECTRICAL MPOE KP KP KP KP KP KPFITNESS30'- 0" X 58 '- 6"YOGA30'-0" X 17 ' -0 "CO-WORK20'-6" X 27 ' -4 "LEASING25'-0" X 32 ' -0 " RESTR OOMOFFICE 11'-0 " X 11 ' -0 "OFFICE11'-0" X 1 1 '- 0 "OFFICE 11'-0 " X 11 ' -0 "OFFICE11'-0" X 1 1 '- 0 "BREAK RM .11'-0" X 1 6 ' -0 "ENTERTAINMENT44'-0" X 23 ' -0 "CONF. 17'-0" X 13 ' - 6"CONF . 10'-0 " X 13 ' -6 "PORCH19'-0" X 22 ' -0 "##### ## # ## ## ###### ## ## ## ####### ## ## ## ## #### ## # ## ## ##POOL EQU IP . 10'-3" X 15 ' - 0" WC WCSHOWE RS MAIL UP UP5' DIA.TRASHROOMTENAN T TRA SHROOMRETAILTRASH RM5' DIA.TRASHROOMTEN AN TTRASHROOMC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCGGTURNAROUNDEND OFLOWER LEVGATECCCCCCCCCCCC3.1% RAMP UP 1.6% RAMP UP4.6% RAMP DN 4.0% RAMP UP @ 247' = 10'-0"ELECTRICALROOMCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG GGGGGTURNAROUNDGGG1234567891011121314151617181920212223242526272829303132333435363738394012345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485UPA4A4A4A3A4A4A4A430"24 49 B4B3A4B3 ABOVEA4A5A1B1A330"2449 30"2449A3 A5A5A3A5ELECT. ROOMMAINT.SHOPA5A5BREAKFASTREST.3,700 SFDININGPATIO1,200 SFSALON NAILSSHOPMEXICANREST.4,600 SFDININGPATIO1,900 SFLOBBYPASSAGEWAYPASSAGEWAYPARKING ENTRYA4A3A430"24 49 PASSAGEWAYA1 ABOVEA3 ABOVEB3 ABOVE30"24 49 PASSAGEWAYSERVICE CORRIDOR SERVICE CORRIDOR OPEN OPENOPEN B4A5A5B1B3B1A5B330"24 49 A330"24 49 A3B3B1A5A5A5B3B3B3 ABOVE20PASSAGEWAYB4A1B3A5A1A1A1PASSAGEWAY#############LOBBYFITNESSCOURTYARDPOOLCOURTYARD 16 17 13 13 15 17B39LVLV30"2449A3 A118A3 ABO VE A330"24 49POOLEQUIPMENTMAIL& PARCELS###########MEN WOM EN B3 ABO VE B3ALT 2B3ALT 1A5ALT 2B4ALT 1B4ALT 2B4A5ALT 1LVA8T.B.D34 STALLSCOMMERCIAL PARKINGCOMMERCIAL 85 STALLSRESIDENTIAL40 STALLS 14 18 134.8%7.2% 16 15.6 12.5 17 16 17 18 18 17 18 18 18 16 18A330"24 49 ELECT. ROOMB 3 A330"24 49ELECT. ROOM32BREAKFASTREST.3,700 SFDININGPATIO1,200 SFSALON NAILSSHOPMEXICANREST.4,600 SFDININGPATIO1,900 SF123456789121110G-2G-3G-4G-1G-6G-5G-7MILLIKEN AVE. ELM AVE.CHURCH ST .TMAINT.EXISTINGTERRA VISTA COMMONSRETAIL CENTERN.A.P. EXISTING SHELL STATIONB-1237-PLEXB-1123-PLEXB-1037-PLEXB-720-PLEXB-623-PLEXB-320-PLEXB-423-PLEXB-837-PLEXB-923-PLEXB-137-PLEXB-223-PLEXG-76-GARAGESG-628-GARAGESG-530-GARAGESG-422-GARAGESG-320-GARAGESG-224-GARAGESG-118-GARAGESFOOTHILL BOULEVARDB-520-PLEXMAINT.WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283B2.8WRAP - PARKING GARAGE - LINE OF SIGHT VIEWS51627348VIEW 1 " LOOKING SOUTH FROM CHURCH STREET INTO COMMUNITY, APPROXIMATELY 350' FROM THE NEAREST FACE OF THE WRAP BUILDING".VIEW 2 " LOOKING SOUTH FROM THE INTERSECTION OF CHURCH STREET AND MILLIKEN AVE INTO COMMUNITY, APPROXIMATELY 340' FROM THE NEAREST FACE OF THE WRAP BUILDING".VIEW 3 "LOOKING NORTHWEST FROM THE INTERSECTION OF MILLIKEN AVE AND FOOTHILL AVE INTO COMMUNITY, APPROXIMATELY 160' FROM THE NEAREST FACE OF THE WRAP BUILDING".VIEW 4 " LOOKING NORTHEAST FROM FOOTHILL AVE INTO COMMUNITY, APPROXIMATELY 170' FROM THE NEAREST FACE OF THE WRAP BUILDING". ELECTRICAL MAINSERVICE ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KP ELECTRICAL KP KP ELECTRICAL ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KP KP KP KP KP KP KP KP KP KP UP18R KPKP KP KP S KP KP KP KP KP KP KP ELECTRICAL MAINSERVICE MPOEKPKPKPELECTRICAL UP18RFIRE RISER UP18R S S/CJ SS/C S ELECTRICAL MAINSERVICE MPOEKPKP KP ELECTRICAL KP KPKPKPKPKP KP KP KP KP UP18RSSDS/CFIRERISER UP18RKP KP KP KP S KP KP KP KP KP KP KP ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL UP18RFIRE RISER UP18R S S/C JSS/C SELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL KP KP KP KP KP KP KP KP KPKP UP18R S SD S/C FIRERISER UP18R KP KP KP KP SKP KP KP KP KP KP KP ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL UP18R FIRE RISER UP18R KPKP KP KP S KP KP KPKPKP KP KPELECTRICAL MAIN SERVICEMPOE KP KP KPELECTRICAL UP18R FIRE RISER UP18R KP KP KP KP SKP KP KP KP KPKP KP ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL UP18R FIRE RISER J SS/C SSPATIO JSS/CSPATIO J SS/C KPKPKPKPKPKP ELECT R IC A L MPOE FIRE RIS E R KPKPKPKP UP18R KP KP KP KP UP18R KP KP KP ELECT R IC A L M A IN S ER V IC E ELECTR I CA L S SD S/C S REF 3DP CB SD S/C S J S S/C S S PATIOJSS/CS PATIO J S S/C KPKPKP KP KP KP ELECTRICALMPOEFIRE RISER KP KPKPKP UP18RKPKPKP KP UP18R KPKP KP ELECTRICAL MAIN SERVICEELECTRICALS SDS/C SREF3DPCB SDS/CS J S S/C S S PATIO J SS/C S PATIOJ SS/C KP KP KPKP KP KP ELECTRICALMPOEFIRE RISER KP KP KPKPUP18R KPKPKP KP UP18RKP KP KP ELECTRICAL MAIN SERVICEELECTRICALSSDS/CS REF3DPCB SDS/CS J SS/C SSPATIOJS S/C S PATIO JS S/C KP KP KP KP KP KP ELECTRICALMPOEFIRE RISER KP KP KP KP UP18RKP KP KP KP UP18R KP KP KP ELECTRICAL MAIN SERVICE ELECTRICAL S SDS/C S REF3DP CBSD S/C S2 2 2 PRINTER 222 PRINTER 2 2 PRINTER22 PRINTER2 2BREEZW AYMPOE/IT JAN I TORMAINT ENA NC E/STORAGE RESTR OOM MEN WOMENELEC . ELECTRICAL ELECTRICAL MAINSERVICE MPOE KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KP KPRTRTMAINT. RM. KP KP UP18R SS/C JSS/C S ELECTRICAL MAINSERVICE MPOE KP KP KP ELECTRICAL KP KP KP KP KP KP KP UP18RS SD S/C FIRERISERKPKPDUMPSTERBY OTHERSA(TRASH)DUMPSTERBY OTHERSA(TRASH) KP DUMPSTERBY OTHERSA(TRASH) ELECTRICAL MAINSERVICEELECTRICALMPOE KP KP KP KP KP KP KP KP KPKPKPKPKPKPKPKPKP KP ELECTRICAL MAINSERVICEELECTRICAL MPOE KP KP KP KP KP KP KP KP KP KP KPKPKPKP KP KP KPKPKPKP KP KP KPKP ELECTRICAL MPOE KP KP KP KP KP KPFITNESS30'- 0" X 58 '- 6"YOGA30'-0" X 17 ' -0 "CO-WORK20'-6" X 27 ' -4 "LEASING25'-0" X 32 ' -0 " RESTR OOMOFFICE 11'-0 " X 11 ' -0 "OFFICE11'-0" X 1 1 '- 0 "OFFICE 11'-0 " X 11 ' -0 "OFFICE11'-0" X 1 1 '- 0 "BREAK RM .11'-0" X 1 6 ' -0 "ENTERTAINMENT44'-0" X 23 ' -0 "CONF. 17'-0" X 13 ' - 6"CONF . 10'-0 " X 13 ' -6 "PORCH19'-0" X 22 ' -0 "##### ## # ## ## ###### ## ## ## ####### ## ## ## ## #### ## # ## ## ##POOL EQU IP . 10'-3" X 15 ' - 0" WC WCSHOWE RS MAIL UP UP5' DIA.TRASHROOMTENAN T TRA SHROOMRETAILTRASH RM5' DIA.TRASHROOMTEN AN TTRASHROOMC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCGGTURNAROUNDEND OFLOWER LEVGATECCCCCCCCCCCC3.1% RAMP UP 1.6% RAMP UP4.6% RAMP DN 4.0% RAMP UP @ 247' = 10'-0"ELECTRICALROOMCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG GGGGGTURNAROUNDGGG1234567891011121314151617181920212223242526272829303132333435363738394012345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485UPA4A4A4A3A4A4A4A430"24 49 B4B3A4B3 ABOVEA4A5A1B1A330"2449 30"2449A3 A5A5A3A5ELECT. ROOMMAINT.SHOPA5A5BREAKFASTREST.3,700 SFDININGPATIO1,200 SFSALON NAILSSHOPMEXICANREST.4,600 SFDININGPATIO1,900 SFLOBBYPASSAGEWAYPASSAGEWAYPARKING ENTRYA4A3A430"24 49 PASSAGEWAYA1 ABOVEA3 ABOVEB3 ABOVE30"24 49 PASSAGEWAYSERVICE CORRIDOR SERVICE CORRIDOR OPEN OPENOPEN B4A5A5B1B3B1A5B330"24 49 A330"24 49 A3B3B1A5A5A5B3B3B3 ABOVE20PASSAGEWAYB4A1B3A5A1A1A1PASSAGEWAY#############LOBBYFITNESSCOURTYARDPOOLCOURTYARD 16 17 13 13 15 17B39LVLV30"2449A3 A118A3 ABO VE A330"24 49POOLEQUIPMENTMAIL& PARCELS###########MEN WOM EN B3 ABO VE B3ALT 2B3ALT 1A5ALT 2B4ALT 1B4ALT 2B4A5ALT 1LVA8T.B.D34 STALLSCOMMERCIAL PARKINGCOMMERCIAL 85 STALLSRESIDENTIAL40 STALLS 14 18 134.8%7.2% 16 15.6 12.5 17 16 17 18 18 17 18 18 18 16 18A330"24 49 ELECT. ROOMB 3 A330"24 49ELECT. ROOM32BREAKFASTREST.3,700 SFDININGPATIO1,200 SFSALON NAILSSHOPMEXICANREST.4,600 SFDININGPATIO1,900 SF123456789121110G-2G-3G-4G-1G-6G-5G-7MILLIKEN AVE. ELM AVE.CHURCH ST .TMAINT.EXISTINGTERRA VISTA COMMONSRETAIL CENTERN.A.P. EXISTING SHELL STATIONB-1237-PLEXB-1123-PLEXB-1037-PLEXB-720-PLEXB-623-PLEXB-320-PLEXB-423-PLEXB-837-PLEXB-923-PLEXB-137-PLEXB-223-PLEXG-76-GARAGESG-628-GARAGESG-530-GARAGESG-422-GARAGESG-320-GARAGESG-224-GARAGESG-118-GARAGESFOOTHILL BOULEVARDB-520-PLEXMAINT.WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-28351627348VIEW 5 "LOOKING SOUTHEAST FROM CHURCH STREET INTO COMMUNITY, APPROXIMATELY 580' FROM THE NEAREST FACE OF THE WRAP BUILDING".VIEW 6 " LOOKING SOUTH FROM THE INTERSECTION OF CHURCH STREET AND MILLIKEN AVE INTO COMMUNITY, APPROXIMATELY 470' FROM THE NEAREST FACE OF THE WRAP BUILDING".VIEW 8 "LOOKING NORTHEAST FROM FOOTHILL AVE INTO COMMUNITY, APPROXIMATELY 690' FROM THE NEAREST FACE OF THE WRAP BUILDING".VIEW 7 " LOOKING NORTHWEST FROM FOOTHILL AVE INTO COMMUNITY, APPROXIMATELY 420' FROM THE NEAREST FACE OF THE WRAP BUILDING".EXISTING TERRA VISTACOMMONS BUILDINGEXISTING McDONALD'SRESTAURANTB2.9WRAP - PARKING GARAGE - LINE OF SIGHT VIEWS 48"22"BREEZWAY5'-0"ELECTRICALMPOEKPKPKPKPKPKPUP18RSS SSKP KPKP ELECTRICAL M A I N SERVICE MPOE KP KP KP ELECTRICAL UP18RS S D S / C KP KP KP KP KP KP KP SKPSSSSSSUP18RUP18RS40'-6"SSDS/C SKP KP KP KP KP KP KP KP KP KP KPKP KP KP KP KP KPSSELECTRICAL MAINSERVICEMPOEKPKPKPELECTRICALUP18RSKPKPKP4:12PER FOOT4:12PER FOOT4:12PER FOOT4:12PER FOOT 4:12PER FOOT 43444647UP UP5' DIA.TRASHROOMTENANTTRASHROOMRETAILTRASH RM5' DIA.TRASHROOMTENANTTRASHROOMC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCGGTURNAROUNDEND OFLOWER LEVGATECCCCCCCCCCCC1234567891011121415161718192021222324252930313233343536373839404142454849 50 51 52 53 54 55565758596061626364656667686970717273747576777879808182838485868788899091929395969798991001011021031041051061071081091101111121131141151161171181191201211221231243.1% RAMP UP 1.6% RAMP UP4.6% RAMP DN 4.0% RAMP UP @ 247' = 10'-0"ELECTRICALROOMCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG GGCGGTURNAROUNDCGGUPTURNAROUNDA4A4A4A3A4A4A4A430"2449B4B3A4B3 ABOVE14'-6"TTA414'-6"A5A1B1A330"244930"2449A3A511'-5"A5A3A5ELECT. ROOMMAINT.SHOPA5A5BREAKFASTREST.3,700 SFDININGPATIO1,200 SFSALON NAILSSHOPMEXICANREST.4,600 SFDININGPATIO1,900 SFLOBBYPASSAGEWAYPASSAGEWAYPARKING ENTRY46'-3"91'-3"114'-3"A4A3A430"2449 PASSAGEWAYA1 ABOVEA3 ABOVEB3 ABOVE30"24 49PASSAGEWAYSERVICE CORRIDORSERVICE CORRIDOROPEN OPENOPEN B4A5A5B1B3B1A5B330"24 49A330"24 49A3B3B1A5A5A5A1 ABOVEB3B3B3 ABOVESTOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"20STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"PASSAGEWAYB4A1B3A5A1A1A1PASSAGEWAY1,077 SQ. FT.LOBBYFITNESSCOURTYARDPOOLCOURTYARD 16 17 13 13 15 17STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"MILLIKEN AVE.FOOTHILL BLVD.B3492'-8" 519'-7" 65'-3"123'44'-10"110'101'-7"74'-11"189'-9"221'-10"410'-2"58'-5" 27'-4"STOR.UNIT4'-0" X 4 '-8 "STOR.UNIT4'-0" X 4 '-8"STOR.U N I T 3'- 4 " X 4 ' - 4 "STOR.UNIT3'- 4 " X 4 ' - 4 " ST O R .UNIT3'- 4 " X 4 ' - 4 "STOR.U N I T3'-4" X 4'-4"STOR.UNIT3'-4" X 4'-4"ST O R .UNIT3'- 4 " X 4 ' - 4 "STOR.UNIT3'- 4 " X 4 ' - 4 " ST O R .UNIT3'- 4 " X 4 ' - 4 "STOR.UNIT3'- 4 " X 4 ' - 4 "STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"9STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"LVSTOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3 '-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"LVSTOR.UNIT3'-6" X 4 '-0"STOR.UNIT4'-0" X 3 '-6"STOR.UNIT4'-0" X 3 '-6"STOR.UNIT3'-6" X 4 '-0"STOR.UNIT3'-6" X 4 ' -0"STOR.UNIT4'-0" X 3 '-6 "30"2449A3 28'-2"12'-4"A119'-10"19'-10"26'19'-10"19'-10"26'22'-10"12'-4"16'-2"27'-3"26'-9"30'25'14'-9"14'-1"13'-2"11'-6"17'-4"12'-5"13'15'-11"26'15'-5"29'-3"19'30'-4"31'-2"32'-2"19'187' 6'A3 ABOVEA37'30"2449POOLEQUIPMENTSTOR.UNIT4'-0" X 3'-5"STOR.UNIT4'-0" X 3'-5"STOR.UNIT4'-0" X 3'-5"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"7'MAIL& PARCELS966 SQ. FT.7'7'7'7'6'7'MENWOMENSTOR.UNIT3'-4" X 4 '-0"STOR.UNIT3'-4" X 4 ' -0"STOR.UNIT3'-4" X 4 ' -0"STOR.UNIT3'-4" X 4 ' -0 "STOR.UNIT3'-4" X 4 ' -0"STOR.UNIT3'-4" X 4 '-0"STOR.UNIT3'-4" X 4 '-0"STOR.UNIT3'-4" X 4 '-0"B3 ABOVE STOR.UNIT3'-6" X 4'-8"7'7'46'-2"46'-2"47'100'38'-8"58'-6"61'-3"75'24'-5"49'-8"49'-8"B3ALT 2B3ALT 17'7'A5ALT 2B4ALT 1B4ALT 27'7'B4A5ALT 1STOR.UNIT5'-2" X 3'-4"LVA8T.B.D48"22"BREEZWAY5'-0"33 STALLSCOMMERCIAL PARKINGCOMMERCIAL 85 STALLSRESIDENTIAL40 STALLS12345678910111213141617181920212223242526272830313233 14 18 134.8%7.2% 16 15.6 12.5 17 16 17 18 18 17 18 18 18 16 18A330" 24 49ELECT. ROOMB3A330"2449ELECT. ROOMSTOR.UNIT3'-6" X 4 ' -0 "STOR.UNIT3'-6" X 4 '-0"STOR.UNIT3'-6" X 4 ' -0"STOR.UNIT3'-6" X 4 ' -0 "STOR.UNIT3'-6" X 4 '-0"STOR.UNIT4'-0" X 3 '-6"STOR.UNIT4'-0" X 3 '-6"STOR.UNIT4'-0" X 3 ' -6 "STOR.UNIT4'-0" X 3 ' -6 "STOR.UNIT4'-0" X 3 ' -6"STOR.UNIT4'-0" X 3 ' -6 "STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT32STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"1529ELECTRICAL MAINSERVICE ELECTRICAL MAINSERVICE MPOE KP KP KPKPKPKP ELECTRICAL PKPKPKPKPKPKPKPUP18RSS/CJSS/CSELECTRICAL MAINSERVICEMPOEKPKPKPELECTRICALKPKPKPKPUP18RSSDS/CFIRERISER UP18RK KP SKP KP KP KP KPKPKPELECTRICAL M A I N SERVICE MPOE KP KP KP ELECTRICAL UP18RFIRE RISER KPJSS/C SSPATIOJSS/CSPATIO JSS/C KPKPKPKPKPKPELECTRICALMPOEFIRE RISER KPKPKPKP UP18RKP KP KP KPUP18R KP KP KP ELECTRICAL MA I N S E R V I C E ELECTRICAL SSDS/C S REF3DPCBSDS/CS222PRINTER222PRINTER 22PRINTER22PRINTER22 BREEZWAYMPOE/ITJANITORMAINTENANCE/STORAGERESTROOMMENWOMENELEC.ELECTRICAL MPOE KP KP KP KP KP KPFITNESS30'-0" X 58'-6"YOGA30'-0" X 17'-0"CO-WORK20'-6" X 27'-4"LEASING25'-0" X 32'-0"RESTROOMOFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"OFFICE11'-0" X 11'-0"BREAK RM.11'-0" X 16'-0"ENTERTAINMENT44'-0" X 23'-0"CONF.17'-0" X 13'-6"CONF.10'-0" X 13'-6"PORCH19'-0" X 22'-0"####################################################WWWWWWWWWWWWWWWWWWWWWWWSSSSSSSSSSSSSSSSW W W WW W W W S SWWW WWWWSSSS S S S WSSSSSSSSSS WWF O O T H I L L B L V D .M I L L I K E N A V E . I L L I K E N A V E .F O O T H I L L B L V D .S S S S S S S S S S S W W W W W W W W W W W SSSSSSSSSSSSSWWWWWWWWWWWWWW W WSS SSSSW WWWWW71110G-711'-2" M I7'26'28'-9"12'-9"19'-10"26'19'-10"19'26'23'-2"24'1161762626'32'-4"37'-11"19'-10"26'17'19'-10"26'19'-10"12'-8"26'-2"26'-9"15'-2"19'-2"15'-2"13'19'-10"26'19'-10"6'-6"17'-4"17'15'-6"3' 14'-5" 22'-6"22'-5"25'-4"30'21'-10"14'-10"17'-4"11'-1"13'-1"17'-5"14'-8"1411'-3"15'-9"17'-4"12'-4"11'-6"13'26'-10"26'22'-7"16'-1"1112423514'-6"28'-3"32'30'-4"331'-6"32'-6"1519'26'19'19'26'19'26'91222410'-3"422'-7"11'-4"8'-4"'5'5'1413'3'3'26'6'20'-2"26'5'-8"25'7B-1123-PLEXB-1037-PLEXB-720-PLEXG-76-GARAGESFOOTHILL BOULEVARDMAINT.24'18'18'10'9'10'10' 10'9'10'10' 9'3'-6"4'1"=30'-0"30' 60' 90'0 15'B2.10BUILDING PLANWRAPNORTHWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283GROUND LEVELSTORAGE (125 CUBIC FEET PER 1 DWELLING UNIT)1/16"=1'-0"16' 32' 48'0 8'PARKING DIMENSIONSFIRE WALLWRAP APARTMENTSTYPE VAR-272,000 SF ALLOWED/72,000 SF PROVIDED + FRONTAGE INCREASE AS APPLICABLE4 STORIES ALLOWED/ 4 STORIES PROVIDED60 FEET ALLOWED/ 60 FEET PROVIDEDPARKING STRUCTUREOPEN PARKINGTYPE IBS-2UNLIMITED SF ALLOWED/53,000 SF PER TIER PROVIDED18 TIERS ALLOWED/ 6 TIERS PROVIDED180 FEET ALLOWED/ 60 FEET PROVIDEDBUILDING TYPE AND HEIGHTPATH OF TRAVELR-2 - TRAVEL DISTANCE 250' MAX.M - TRAVEL DISTANCE 250' MAX.S-2 - TRAVEL DISTANCE 400' MAXSTORAGE DIMENSION : 125 CFEXIT PATH UPUP 5' DIA.TENANTTRASHROOMTURNAROUND123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136 137 138 139 140 141 142 143 144 145 146 147 148 149 4.0% RAMP UP @ 247' = 10'-0"4.0% RAMP DN @ 247' = 10'-0"5' DIA.TENANTTRASHROOMRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR R R R R R R RR R R R R R R R R R R R R RRRRRRRRRRRRRRRRRUPA4A4A4A4A4A4A4B4B3A46'14'-6"TB3A414'-6"A5A1B1B3A511'A5A5A5A544'-10"91'-3"114'-3"RESIDENTIAL149 STALLSA4B3A4OPEN OPENOPEN A5A5B1B1A5B330"24 49A330"24 49A3B3B3B1A5A5A5B3B3STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"B4A1B3A5A1A1A1FITNESSCOURTYARDPOOLCOURTYARDLVSTOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"B3492'-10" 519'-7" 59'129'-3"44'-10"110'100'-2"76'-4"188'-4"221'-10"410'-2"STOR.UNIT4'-0" X 4 '-8 "STOR.UNIT4'-0" X 4 '-8" ST O R . U N I T 3'- 4 " X 4 ' - 4 " S T O R . U N I T 3'- 4 " X 4 ' - 4 " ST O R . U N I T 3'- 4 " X 4 ' - 4 " S T O R . U N I T 3'- 4 " X 4 ' - 4 " ST O R . U N I T 3'- 4 " X 4 ' - 4 " S T O R . U N I T 3'- 4 " X 4 ' - 4 " S T O R . U N I T 3'- 4 " X 4 ' - 4 " ST O R . U N I T 3'- 4 " X 4 ' - 4 " ST O R . U N I T 3'- 4 " X 4 ' - 4 "STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"9STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"LVSTOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-3" X 4'-6"LVA16'STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"207'7'7'7'6'7'30" 2 4 49 STOR.UNIT3'-6" X 4'-8"S1S1A6S1 S1A6 A6S1A6 A6S1A6 S1A6S1 S1A6 A6S1A6 A6S1B3A3B37'30"2449A3B3B3A1LV B3B3B3B3A1B4ALT 2B4B3B4B3ALT 1A5ALT 17'B3B3B4ALT 17'B3ALT 2A5ALT 27'7'7'A83'-2 15/16" 28 28 28 28LVSTOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNITSTOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"32STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"24'18'18'10'9'10'10' 10'9'10'10' 9'3'-6"4'NORTH1"=30'-0"30' 60' 90'0 15'B2.11BUILDING PLANWRAPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283SECOND LEVEL1/16"=1'-0"16' 32' 48'0 8'PARKING DIMENSIONSWRAP APARTMENTSTYPE VAR-272,000 SF ALLOWED/72,000 SF PROVIDED + FRONTAGE INCREASE AS APPLICABLE4 STORIES ALLOWED/ 4 STORIES PROVIDED60 FEET ALLOWED/ 60 FEET PROVIDEDPARKING STRUCTUREOPEN PARKINGTYPE IBS-2UNLIMITED SF ALLOWED/53,000 SF PER TIER PROVIDED18 TIERS ALLOWED/ 6 TIERS PROVIDED180 FEET ALLOWED/ 60 FEET PROVIDEDBUILDING TYPE AND HEIGHTSTORAGE (125 CUBIC FEET PER 1 DWELLING UNIT)FIRE WALLSTORAGE DIMENSION : 125 CF UPUP UP5' DIA.TENANTTRASHROOMTURNAROUND123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136 137 138 139 140 141 142 143 144 145 146 147 148 149 4.0% RAMP UP @ 247' = 10'-0"4.0% RAMP DN @ 247' = 10'-0"5' DIA.TENANTTRASHROOMRRRRRRRRRRRRRRRRRRRRRRRGGGGGGRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR R R R R R R RR R R R R R R R R R R R R RRRRRRRRRRRRRRRRRGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGA4A4A4A4A4A4A4B4B3A46'14'-6"TB3A414'-6"A5A1B1B3A511'A5A5A5A544'-10"91'-3"114'-3"A4B3A4OPEN OPENOPEN A5A5B1B1A5B330"2449A330"24 49A3B3B3B1A5A5A5B3B3STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"B4A1B3A5A1A1A1FITNESSCOURTYARDPOOLCOURTYARDLVSTOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"B3492'-10" 519'-7" 59'129'-3"44'-10"110'100'-2"76'-4"188'-4"221'-10"410'-2"STOR.UNIT4'-0" X 4 ' -8"STOR.UNIT4'-0" X 4 '-8" S T O R . U N I T 3'- 4 " X 4 ' - 4 "STOR.U N I T3'-4" X 4'-4"STOR.UNIT3'-4" X 4'-4"S T O R . U N I T 3'- 4 " X 4 ' - 4 " ST O R . U N I T 3'- 4 " X 4 ' - 4 "STOR.UNIT3'-4" X 4'-4"STOR.U N I T3'-4" X 4'-4"STOR.UNIT3'-4" X 4'-4"STOR.U N I T3'-4" X 4'-4"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"9STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"LVSTOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-3" X 4'-6"LVA16'STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"207'7'7'7'6'7'30" 2 4 49 STOR.UNIT3'-6" X 4'-8"S1S1A6S1 S1A6 A6S1A6 A6S1A6 S1A6S1 S1A6 A6S1A6 A6S1B3A3B37'30"2449A3B3B3A1LV B3B3B3B3A1B4ALT 2B4B3B4STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT32B3ALT 1A5ALT 1STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"7'B3B3LVB4ALT 17'B3ALT 2A5ALT 27'7'7'A8 38 38 38RESIDENTIAL149 STALLS30"24 49A3B324'18'18'10'9'10'10' 10'9'10'10' 9'3'-6"4'NORTHWRAPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283B2.12BUILDING PLANTHIRD LEVEL1"=30'-0"30' 60' 90'0 15'1/16"=1'-0"16' 32' 48'0 8'PARKING DIMENSIONSWRAP APARTMENTSTYPE VAR-272,000 SF ALLOWED/72,000 SF PROVIDED + FRONTAGE INCREASE AS APPLICABLE4 STORIES ALLOWED/ 4 STORIES PROVIDED60 FEET ALLOWED/ 60 FEET PROVIDEDPARKING STRUCTUREOPEN PARKINGTYPE IBS-2UNLIMITED SF ALLOWED/53,000 SF PER TIER PROVIDED18 TIERS ALLOWED/ 6 TIERS PROVIDED180 FEET ALLOWED/ 60 FEET PROVIDEDBUILDING TYPE AND HEIGHTSTORAGE (125 CUBIC FEET PER 1 DWELLING UNIT)FIRE WALLPATH OF TRAVELR-2 - TRAVEL DISTANCE 250' MAX.M - TRAVEL DISTANCE 250' MAX.S-2 - TRAVEL DISTANCE 400' MAXSTORAGE DIMENSION : 125 CF UPUP 5' DIA.TENANTTRASHROOMTURNAROUND123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136 137 138 139 140 141 142 143 144 145 146 147 148 149 4.0% RAMP UP @ 247' = 10'-0"4.0% RAMP DN @ 247' = 10'-0"5' DIA.TENANTTRASHROOMGGGGGGRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR R R R R R R RR R R R R R R R R R R R R RRRRRRRRRRRRRRRRRGGGGGGGGGGGGGGGGGGGGGGGGGGGGRRGGUPA4A4A4A4A4A4A4B4B3A46'14'-6"TB3A414'-6"A5A1B1B3A5A5A5A5A544'-10"91'-3"114'-3"A4B3A4OPEN OPEN A5A5B1B1A5B330"2449A330" 24 49A3B3B3B1A5A5A5B3B3STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"B4A1B3A5A1A1A1FITNESSCOURTYARDPOOLCOURTYARDSTOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"B3492'-10" 519'-7" 59'129'-3"44'-10"110'100'-2"76'-4"188'-4"221'-10"410'-2"STOR.UNIT4'-0" X 4 '-8 "STOR.UNIT4'-0" X 4 '-8" ST O R . U N I T 3'- 4 " X 4 ' - 4 "STOR.UNIT3'-4" X 4'-4"STOR.UNIT3'-4" X 4'-4"STOR.UNIT3'- 4 " X 4 ' - 4 " ST O R . U N I T 3'- 4 " X 4 ' - 4 "STOR.U N I T3'-4" X 4'-4"STOR.UNIT3'-4" X 4'-4"STOR.U N I T3'-4" X 4'-4"STOR.UNIT3'-4" X 4'-4"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT3'-9" X 3'-8"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"STOR.UNIT4'-2" X 3'-5"9STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"LVSTOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-8"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT4'-0" X 3'-6"STOR.UNIT3'-6" X 4'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT4'-6" X 3'-6"STOR.UNIT3'-3" X 4'-6"STOR.UNIT3'-3" X 4'-6"LVA1STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"STOR.UNIT5'-2" X 3'-4"207'7'7'7'6'7'30" 2 4 49 STOR.UNIT3'-6" X 4'-8"S1S1A6S1 S1A6 A6S1A6 A6S1A6 S1A6S1 S1A6 A6S1A6 A6S1B3A3B37'30"2449A3B3B3A1LV B3B3B3B3A1B4ALT 2B4B3B4B3ALT 1A5ALT 17'B3B37'A5ALT 27'7'7'ROOF DECK@4TH LEVEL1,788 SQ. FT.LVA8 48 48 48RESIDENTIAL149 STALLS30" 24 49A3B3LVSTOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNIT3'-6" X 4'-8"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNITSTOR.UNIT3'-6" X 4'-2"STOR.UNIT3'-6" X 4'-2"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT32STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"STOR.UNIT4'-0" X 4'-8"11'OPEN24'18'18'10'9'10'10' 10'9'10'10' 9'3'-6"4'NORTH1"=30'-0"30' 60' 90'0 15'B2.13BUILDING PLANWRAPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283FOURTH LEVEL1/16"=1'-0"16' 32' 48'0 8'PARKING DIMENSIONSWRAP APARTMENTSTYPE VAR-272,000 SF ALLOWED/72,000 SF PROVIDED + FRONTAGE INCREASE AS APPLICABLE4 STORIES ALLOWED/ 4 STORIES PROVIDED60 FEET ALLOWED/ 60 FEET PROVIDEDPARKING STRUCTUREOPEN PARKINGTYPE IBS-2UNLIMITED SF ALLOWED/53,000 SF PER TIER PROVIDED18 TIERS ALLOWED/ 6 TIERS PROVIDED180 FEET ALLOWED/ 60 FEET PROVIDEDBUILDING TYPE AND HEIGHTSTORAGE (125 CUBIC FEET PER 1 DWELLING UNIT)FIRE WALLSTORAGE DIMENSION : 125 CF ROOFTOPMECHANICALEQUIPMENTCONCEALED FROMEXTERIOR VIEW BYPERIMETER PARAPETWALLS (TYP.)ROOF ACCESS STAIRROOF ACCESS STAIRUPUP UPTURNAROUND4.0% RAMP UP @ 247' = 10'-0"4.0% RAMP DN @ 247' = 10'-0" UP RR R R R R R R R RRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRR R R R R R R R RR R R R R7:12SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12 SLOPE 7:12 SLOPE 7:12 SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12SLOPE 7:12 SLOPE 7:12SLOPE7:12 SLOPE 7:12SLOPE7:12 SLOPE 7:12 SLOPE 7:12 SLOPE7:12SLOPE7:12SLOPE7:12 SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12 SLOPE 7:12SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12 SLOPE 7:12 SLOPE 7:12 SLOPE 7:12 SLOPE7:12SLOPE7:12SLOPE7:12 SLOPE 7:12 SLOPE 7:12SLOPE7:12SLOPE7:12 SLOPE 7:12 SLOPE 7:12 SLOPE 7:12 SLOPE 7:12SLOPE7:12 SLOPE 7:12 SLOPE 7:12 SLOPE 7:12 SLOPE 7:12 SLOPE 7:12 SLOPE 7:12SLOPE7:12 SLOPE7:12SLOPE7:12SLOPE7:12SLOPE7:12SLOPE 7:12SLOPE7:12SLOPE7:12SLOPE 58 58 58RESIDENTIAL156 STALLSAC UNIT24'18'18'10'9'10'10' 10'9'10'10'NORTH1"=30'-0"30' 60' 90'0 15'B2.14BUILDING PLANWRAPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283FIFTH LEVEL1/16"=1'-0"16' 32' 48'0 8'PARKING DIMENSIONSMECHANICAL EQUIPMENT SCREENINGWRAP APARTMENTSTYPE VAR-272,000 SF ALLOWED/72,000 SF PROVIDED + FRONTAGE INCREASE AS APPLICABLE4 STORIES ALLOWED/ 4 STORIES PROVIDED60 FEET ALLOWED/ 60 FEET PROVIDEDPARKING STRUCTUREOPEN PARKINGTYPE IBS-2UNLIMITED SF ALLOWED/53,000 SF PER TIER PROVIDED18 TIERS ALLOWED/ 6 TIERS PROVIDED180 FEET ALLOWED/ 60 FEET PROVIDED 4.0% RAMP UP @ 247' = 10'-0"TURNAROUNDUP RRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRRESIDENTIAL50 STALLS24'18'18'10'9'10'10' 10'9'10'10'3RD STORYT.O. SHT'G.2ND STORYT.O. PLATE2ND STORYT.O. SHT'G.1ST STORYT.O. PLATE9'-1"4TH STORYT.O. SHT'G.3RD STORYT.O. PLATE9'-1"± 53'-11"TOP OFPARKINGSTRUCTURE9'-1"9'-1"9'-1"3'-6"5TH STORYT.O. SHT'G.4TH STORYT.O. PLATE5'-6"LINE OF SIGHTNORTH1"=30'-0"30' 60' 90'0 15'B2.15BUILDING PLANWRAPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283ROOF LEVEL1/16"=1'-0"16' 32' 48'0 8'PARKING DIMENSIONSWRAP APARTMENTSTYPE VAR-272,000 SF ALLOWED/72,000 SF PROVIDED + FRONTAGE INCREASE AS APPLICABLE4 STORIES ALLOWED/ 4 STORIES PROVIDED60 FEET ALLOWED/ 60 FEET PROVIDEDPARKING STRUCTUREOPEN PARKINGTYPE IBS-2UNLIMITED SF ALLOWED/53,000 SF PER TIER PROVIDED18 TIERS ALLOWED/ 6 TIERS PROVIDED180 FEET ALLOWED/ 60 FEET PROVIDEDSECTION REF34'-0"20'-0"BEDROOM10'-2" X 10'-6"BATHUNIT A11 BEDROOM - 1 BATHNET LIVABLE: 634 SQ. FT.PATIO/DECK : 56 SQ. FT.WICLIVING10'-4" X 12'-9"BALCONY8'-6" X 6'-6"KITCHEN9'-10" X 11'-8"ENTRYQDWW/DP36" x 60"LBUILT-INDESK36" HCBCB3S5 MDF SH.DWKITCHEN8'-0" X 15'-0"ENTRYW/DLIVING12'-10" X 16'-2"BALCONY11'-0" X 5'-6"BEDROOM11'-2" X 12'-0"REFPBATHLUNIT A31 BEDROOM - 1 BATHNET LIVABLE: 759 SQ. FT.PATIO/DECK : 60 SQ. FT.25'-0"33'-0"WIC30"2449 LBUILT-INDESKKOCCURS UNDER 2 BEDROOMCBCB 36"x60" BUILT-INISLAND3S37'-11"29'-4"BALCONY9'-0" X 6'-2"BATHLIVING11'-11" X 12'-11"WICBEDROOM11'-0" X 12'-6"REFKITCHEN8'-5" X 14'-0"DWENTRY5 SHELVESW/DBUILT-INDESKUNIT A41 BEDROOM - 1 BATHNET LIVABLE: 751 SQ. FT.PATIO/DECK : 68 SQ. FT.KPUNDER CABINET LIGHT36"x60" CBCBCOUNTERHEIGHTCABINETBUILT-INISLANDOPENING FOR LIGHTCOUNTER HT BASE CABUNDER CAB LIGHT3SDWKITCHEN10'-0" X 14'-0"W/D27'-0"34'-0"ENTRYBEDROOM11'-2" X 12'-0"LIVING11'-0" X 13'-8"BALCONY11'-0" X 6'-2"FLEX/OFFICE12'-4" X 7'-8"BATHREFWICUNIT A51 BEDROOM + OFFICE - 1 BATHNET LIVABLE: 859 SQ. FT.PATIO/DECK : 66 SQ. FT.DROP ZONEPCB CB K36"x60" BUILT-INISLANDFURNITURE FURNITUREDWBATHCBCBPM. BATHM. BEDROOM11'-0" X 12'-0"WICLENTRYW/DLIVING11'-7" X 13'-0"BEDROOM 210'-4" X 12'-0"KITCHEN11'-8" X 9'-6"BALCONY5'-10" X 8'-4"29'-10"UNIT B1 (ADA)2 BEDROOM - 2 BATHNET LIVABLE: 993 SQ. FT.PATIO/DECK : 44 SQ. FT.FURNITURE44'-1"WICQREFQ36"x60" 36"x60" WORKSPACEFURNITURE3SCB KITCHEN8'-0" X 15'-0"M. BATHWICM. BEDROOM11'-0" X 15'-0"LUNIT B32 BEDROOM - 2 BATHNET LIVABLE: 1,133 SQ. FT.PATIO/DECK : 60 SQ. FT.36'-4"33'-0"DWCBENTRYD/WLIVING12'-10" X 15'-9"BALCONY11'-0" X 5'-6"BEDROOM 211'-2" X 12'-0"REFPBATH 2WICBUILT-INDESKDROP ZONE STO.WORKSPACEKQL36"x60" 36"x60" BUILT-INISLANDFURNITURE3SLCOAT CLOSETCBCBDWREFPUNIT A61 BEDROOM + OFFICE - 1.5 BATHNET LIVABLE: 1004 SQ. FT.PATIO/DECK : 69 SQ. FT.STORAGE : -ENTRYLIVING11'-10" X 15'-0"DWREPOSITIONABLEISLANDWREFBEDROOM14'-0" X 11'-2"BALCONY11'-0" X 6'-2"DININGLENTRYBEDROOM12'-0" X 12'-3"D/WLIVING11'-0" X 12'-0"FLEX/DININGFLEX/OFFICE9'-9" X 9'-6"UNIT S1STUDIO - 1 BATHNET LIVABLE: 659 SQ. FT.PATIO/DECK : 76 SQ. FT.STORAGE : -36'-10"50'-0"BATHBALCONY12'-0" X 6'-2"RETAILSHAFTWICBATHPDROP ZONE3'-10"KQDCBCBPP36"x60" P36"x60" FURNITUREFURNITUREFURNITUREW/D3SREFCBPCBM. BEDROOM 13'-0" X 12'-0"DINING9'-11" X 10'-6"LIVING14'-2" X 12'-0"BEDROOM 212'-0" X 11'-0"36'-0"ENTRYM. BATHWICLWORKSPACEDWKITCHEN12'-10" X 9'-0"BALCONY8'-0" X 7'-8"UNIT B42 BEDROOM - 2 BATHNET LIVABLE: 1,261 SQ. FT.WORKSPACEKQBATH 2LWORKSPACE36"x60" 36"x60" FURNITUREFURNITUREFURNITURE BUILT-INISLANDB3.0UNIT PLANS - WRAPS 3/16"=1'-0"4' 8' 16'0 2'1'4-STORY WRAPWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-12-22JOB NO.: 2019-283 Exhibit D Exhibit E WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-07-22JOB NO.: 19-043L7OVERALL COMMUNITY PERSPECTIVES WDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEHARVEST AT TERRA VISTAN/W CORNER OF FOOTHILL BLVD. & MILLIKEN AVE. RANCHO CUCAMONGADATE: 01-07-22JOB NO.: 19-043L8OVERALL COMMUNITY PERSPECTIVES Page 1 of 6 HARVEST AT TERRA VISTA Master Plan 04/27/2022 Exhibit G Page 2 of 6 SITE PLAN N Page 3 of 6 DETAILED SITE PLAN N Page 4 of 6 VEHICULAR CIRCULATION PLAN Land Use Mix N Page 5 of 6 PEDESTRIAN CIRCULATION PLAN N Page 6 of 6 SUMMARY TABLES SITE-SPECIFIC DEVELOPMENT STANDARDS Development Standard Proposed (Master Plan) Density 36 DU/AC Front Setback - Foothill Boulevard Public ROW 0’ to 23’ Front Setback – Milliken Avenue Public ROW 12’ to 20’ Front Setback – Church Street Public ROW 15’ to 23’ Front Setback – Elm Avenue Public ROW 10’ to 15’ Front Setback - Interior Streets (Applicable to all building frontages facing interior streets) 5’ to 7’ Interior Setback – West property line facing adjacent shopping center 124’ Interior Setback - South property line facing adjacent shopping center 56’ Distance Between Buildings Per Building Code Building Height – Walk-Ups 3 Stories Building Height – Wrap Building 4 Stories Landscape Area (Overall net area) Min. 10% Open Space Min. 150 SF/unit (100,650 SF) Parking RCMC Chapter 17.64 1 – Measured from Property Line. For interior streets, property line is considered to be the back of sidewalk. PARKING Number of Units Square Footage Parking Ratio Required Parking Multi-Family unit (studio) 117 N/A 1.3 per unit (1 in garage or carport) 152 Multi-family unit (One bedroom) 347 N/A 1.5 per unit (1 in garage or carport) 521 Multi-family unit (Two bedrooms) 207 N/A 2 per unit (1 in garage or carport) 414 Visitor parking 671 N/A 1 per 3 units 224 Commercial (Retail) N/A 8,590 4 per 1000 square feet 34 Commercial (Restaurant) N/A 12,251 10 per 1000 square feet 123 Total Parking Spaces Required 1,468 Total Parking Spaces Provided 1,468 Total Covered Parking Spaces Required/Provided 671/942 LAND USE MIX / UNIT BREAKDOWN Residential Unit Type 3-Story Walk-Up 4-Story Wrap Total Studio 84 33 117 1 Bedroom 153 194 347 2 Bedroom 86 121 207 TOTAL 323 348 671 Commercial Commercial (SF) N/A 20,841 20,841 I' I Exhibit H LEGEND -�'HN,TO l(H,t,)((il,Vf!'ltAe,!C)#l6') --rH10il!T06'MlDl!�T Ill IUHt 6' TO IO' 1-1101! �T -·-1-"WDl!'�T •••••••• OTl-l8t �!IIUTY •l'ITl-1& -""f&:l<.e,./\TI-1 '---------== FOOTHILL BLVO, -------------=--=--=--=-=--=------ HARVEST AT TERRA VISTA N/W CORNER OF FOOTHILL BLVD, & MILLIKEN AVE, RANCHO CUCAMONGA WDCC MILLIKEN WEST RESIDENTIAL, LLC 1156 N. MOUNTAIN AVE. UPLAND, CA 91786 (909) 985-0971 ;,---· \ \ ,\ \ I FOO THILL ♦ ' I ' I ' � <;:: I" ' "' I"' ,. I"' 'I BLVO. NORTH -• ., "' ,,. WALKWAY CIRCULATION EXHIBIT DATE: 01�7�22 JOB NO.: 19-0--43 ARCHITECTS ORANGE 144 NORTH ORANGE ST.. ORANGE, CA 92866 (714) 639-9860 ,, L2 AO MEMORANDUM Date: March 29, 2022 To: Brian Jacobson, Lewis Management Corp From: Spencer Reed, PE and Jason Pack, PE Subject: Harvest at Terra Vista Parking Management Plan OC22-0877 This memorandum presents the parking management plan for the Harvest at Terra Vista (Project) development in the City of Rancho Cucamonga, California. This parking management plan was prepared based the requirements of the City of Rancho Cucamonga Municipal Code Section 17.64.070. Project Description The Project is bounded by Elm Avenue to the west, Milliken Avenue to the east, Foothill Boulevard to the south, and Church Street to the north. The southwest corner of this block contains existing retail uses, including a fast-food restaurant, which are not part of the Project, but will be utilized to meet the commercial parking requirements. The Project comprises of the following land uses: 323 three-story walk-up dwelling units 348 wrap product dwelling units 20,841 sq. ft. of commercial space o 8,590 sq. ft. of retail space o 12,251 sq. ft. of restaurant space The Project proposes to provide 1,310 residential parking spaces. The residential parking includes spaces for residents and guests with the use of angled and perpendicular parking on internal drive aisles, parking in private garages, and driveway spaces behind some of the garages. The Project Exhibit J Brian Jacobson March 29, 2022 Page 2 of 9 provides the required number of residential parking spaces per the City of Rancho Cucamonga Municipal Code Section 17.64.050. The Project proposes to provide 85 commercial parking spaces in the lower level of the wrap residential parking structure and 35 parking spaces in the surface lot adjacent to the wrap building, with the remaining requirement of 37 spaces to be fulfilled by sharing surface parking with the existing commercial development. The Project also proposes to implement a parking management plan. Table 1 summarizes the proposed commercial parking supply for the Project. The existing Terra Vista Commons commercial development, which is directly adjacent to the Project site, consists of the following uses:  7,100 sq. ft. of retail space  2,790 sq. ft. of restaurant space  3,500 sq. ft. of fast-food space It should be noted that all parcels of the existing commercial development have one owner. That owner also owns the multi-tenant commercial building. The fast food restaurant has a separate owner and a ground lease from the owner of the commercial center. The existing surface parking lot operates as one large shared parking pool, the existing uses and the total parking supply are considered as one development for the purposes of this analysis. However, it should be noted that our observations indicate that the bulk of the non-utilized parking on the site consists of the exiting spaces between the McDonalds’s building and the AT&T store, north of those buildings. The existing surface parking lot contains 160 parking spaces. Since the commercial use of the Project will have designated parking, and will be parked separately from the residential uses, the remainder of this memorandum addresses the proposed shared parking between the existing and proposed retail on the site. Parking Required Per City Code Table 2 summarizes parking requirements of the commercial portion of the Project and the existing commercial development per the Rancho Cucamonga Municipal Code Section 17.64.050. As shown in the table, a total of 157 parking spaces are expected to be required for the proposed Project’s commercial use per the City’s municipal code. Additionally, a total of 91 parking spaces are required of the existing commercial development. Brian Jacobson March 29, 2022 Page 3 of 9 Project Shared Parking Analysis A shared parking analysis was conducted using methodologies and assumptions provided in Shared Parking, 3rd Edition (Urban Land Institute [ULI], 2020). The ULI sponsored a national study that established a basic methodology for analyzing parking demand in mixed-use developments and developed averages for parking rates by land use. The analysis presented in this memorandum utilizes the data from the Shared Parking, 3rd Edition report. The shared parking methodology establishes the base parking rate, parking demand reductions, and hourly/monthly demand patterns for each land use. The overall parking demand is calculated by considering the parking demand patterns and parking demand reductions (potential for non- auto modes and internal capture) for each component of the project being analyzed. Information regarding the parking rates, parking demand reductions, and parking demand patterns for the Project and the existing commercial development is provided below. Parking Rates The shared parking analysis for the Project’s commercial use utilized the City of Rancho Cucamonga parking requirements that were adjusted to match the proportions base parking rates for customers and employees as determined by ULI. Table 3 identifies the parking allocation of customers and employees and demonstrates that the parking requirement for the commercial portion of the Project meets the City of Rancho Cucamonga parking requirement of 157 parking spaces. Table 3 also identities the parking rates developed for the existing commercial development which reflects the 91 parking space requirement. Separate rates were used for weekday and weekend and for customers and employees. The derived rates use the daily/hourly/seasonal patterns for calculating the parking demand based on the unique travel characteristics of the project being analyzed. Adjustments were made for two travel factors to match the ULI shared parking methodology: the potential for non-auto modes and the estimated non-captive (otherwise known as internal capture) of parking between the land uses in the area (e.g. people from the on-site residential uses accessing the retail). Parking Demand Reductions The shared parking analysis allows for adjustment in the base parking rate due to factors such as mode split/walk-in and non-captive ratio. These factors are based on the mix of uses in the project, Brian Jacobson March 29, 2022 Page 4 of 9 size of the uses, and location of the project. Additional information regarding these factors is provided below.  Mode Adjustment – One factor that affects the overall parking demand at a particular development is the number of visitors and employees that arrive by automobile. The alternatives considered in the analysis account for the effects of pedestrian, bicycle, drop- off, and transit access to the site.  Noncaptive Ratio – Also known as trip internalization. Based on data from empirical studies through sources such as ULI, it is known that a certain percentage of trips in mixed-use developments (depending on the mix of land uses in the project) are trips moving between the land uses on-site, i.e., they were internally captured on the site. Adjustments were made to the analysis to account for trip internalization. Table 4 documents the adjustment percentages applied to customers and employees to each of the land uses for different periods of the day. Although Foothill Boulevard provides frequent transit opportunities to access the commercial development and increased residential development along the corridor will allow for additional pedestrian/bicycle activity to the site, we assumed no mode split adjustment to reflect a conservative condition of all customers and employees driving to the site. The non-captive ratio was applied based on the mix and size of the uses in the Project and existing commercial development. These ratios were based on standards provided in Shared Parking, 3rd Edition. It is assumed that some patrons will only park a vehicle once but visit multiple components of the Project and existing commercial development. Parking Demand Patterns The shared parking analysis uses monthly adjustment factors and time-of-day adjustment factors to account for the variation in parking demand for different land uses. Based on the anticipated land uses and parking demand reductions applied, monthly adjustment factors are applied based on the month that will result in the greatest parking demand (peak month). The time-of-day factors are applied to the peak month demand to determine the estimated parking demand throughout the day. Table 5 documents the weekday peak month adjustment and time-of-day adjustment for customers and employees. Table 6 documents the weekend peak month adjustment and time-of- day adjustment for customers and employees. Brian Jacobson March 29, 2022 Page 5 of 9 Shared Parking Demand Table 7 summarizes the shared parking analysis of the existing commercial development using the methodology and assumptions described above. As shown in the table, an estimated peak parking demand of 89 spaces (74 for customers and 15 for employees) will occur on a weekend at 12:00 PM in December. With inclusion of the Project an estimated peak parking demand of 240 spaces (203 for customers and 37 for employees) will occur on a weekend at 12:00 PM in December as documented in Table 8. Table 9 and Table 10 present the estimated total parking demand distribution by each land use category for weekday and weekend day, respectively. Figure 1 and Figure 2 show weekday and weekend shared parking demand estimates for each month of the year. Demand for the month of December is divided into “December” and “Late December”. Existing Parking Demand A parking survey of the existing commercial development was conducted during the evening of March 10, 2022. Peak parking demand was found to be approximately 27 vehicles at 6:00 PM. According to the shared parking analysis conducted for the existing commercial development, a parking demand of 69 vehicles would be expected at 6:00 PM in March. The existing site parking observations indicate half of the demand compared to what was estimated using the shared parking methodology that was adjusted to reflect City parking code requirements. Therefore, it can be assumed that the actual peak parking demand at 12:00 PM as determined in Table 7 could be lower than the 88 spaces identified and provides a conservative assessment. Parking Supply and Demand Conclusions The shared parking analysis of the existing commercial development and the commercial portion of the Project, utilizing City parking requirements, ULI parking demand reductions, and time-based demand patterns resulted in a weekday parking space demand of 235 spaces and a weekend parking space demand of 240 spaces. According to the Rancho Cucamonga Municipal Code Section 17.64.050, the Project would require 248 parking spaces (91 for the existing commercial development and 157 for the Project). While the Project will provide less spaces than required per the Rancho Cucamonga Municipal Code (120 proposed compared to 157 required), the site commercial parking supply of 280 spaces (160 existing and 120 proposed) and use of shared parking will satisfy the estimated parking demand. Brian Jacobson March 29, 2022 Page 6 of 9 Although the shared parking assessment within the commercial portion of the Project indicates that there will be sufficient parking provided, there is the potential for parking from the residential to “spill out” into the commercial parking if parking for the entire site is not properly managed. As such, we have provided the following parking management recommendations in the following section that should be considered. Parking Management Recommendations The following recommendations are aimed to provide an organized and systematic parking management plan for the Harvest at Terra Vista while mitigating parking congestion in the site’s surrounding neighborhoods. These recommendations should be continually reviewed/updated as needed to maximize the efficiency of the parking facilities if necessary. Commercial Parking Recommendations Commercial Parking Locations All commercial parking will be required to park on-site in designated spots identified for commercial parking. These non-reserved parking spaces will be utilized on a first come first serve basis. Commercial users are not allowed to park in residential or guest parking spaces and shall not park in nearby neighborhoods. Even if residential and guest parking spaces are unassigned, commercial users are neither allowed to utilize the unassigned resident parking spaces nor will have access to any gated resident parking area. Static Signage Static signage should be installed within the Project site to guide vehicles to the associated parking facilities. Signage should also be installed within the parking facilities identifying specific parking spaces or identifying the facility as commercial parking for the Project or provides time restrictions that prevents over-night parking within the commercial parking area. The installation of static signage can inform visitors of their parking options and direct them to locations them may not associate with the commercial component of the Project. Assigning Parking Locations Assigning parking locations to commercial employees could reduce demand on desired parking spaces. Employees could be assigned to harder to find or further away commercial parking spaces to free up closer parking spaces for guests. Additionally, assigned employee spaces could be Brian Jacobson March 29, 2022 Page 7 of 9 strategically located closest to the residential uses to better management potential parking spill over from the residential uses on the site. Accommodating Transportation Network Companies Providing dedicated pick-up and drop-off locations to Transportation Network Companies (TNC’s) such as Uber and Lyft could reduce the parking demand. While the parking demand calculations do not consider parking demand reductions due to alternative modes of transportation, encouragement of TNCs through dedicated pick-up and drop-off locations could result in customers choosing not to drive and park a vehicle. Promoting Other Modes of Transportation Encouraging the use of other modes of transportation such as transit, bicycles, and walking could reduce parking demand. While the parking demand calculations do not consider parking demand reductions due to alternative modes of transportation, encouragement of these types of transportation options through improving transit stops, bicycle parking, or sidewalk improvements could result in customers choosing not to drive and park a vehicle. Residential Parking Recommendations Resident Parking Location All residents and their guests will be required to park on site in designated residential parking spaces. Only residents and their guests with be granted access to the residential parking areas. Guest Parking Location Guest parking will be available on a first-come, first-served basis within the residential community. With appropriate registration, guests will be allowed to park in any unmarked, unassigned residential parking space. Guests are not allowed to park in commercial parking spaces and shall not park in nearby neighborhoods. Register Vehicles with Management All resident vehicles will be required to be registered with building management as part of their lease agreement. Only those registered vehicles will be allowed to park within the community. Management staff will monitor the amount of resident parking spaces that are available. Units will not be leased to tenants if a potential tenant has more vehicles than spaces allotted for their unit. Brian Jacobson March 29, 2022 Page 8 of 9 Assigned Vehicle Parking All resident vehicles will be assigned a specific parking spot that is numbered and reserved for the specific vehicles use only. Parking spaces are assigned to one (1) specific resident vehicle only and are not able to be shared with other resident or guest vehicles. If a tenant’s vehicle information should change, it is the responsibility of the tenant to notify management in accordance with the lease agreement. Security / Monitoring Management staff and security personnel will be on-site daily from 8am-2:30am to monitor and enforce compliance with the requirements of the Parking Management Plan and the requirements set for in the tenants’ lease agreements. Cameras will be also be utilized to monitor the parking areas. Any violation of the parking requirements set forth in the tenants’ lease agreements will be subject to towing, revoked parking privileges, and/or eviction. Management staff will employ parking enforcement software to enforce parking rules. Management staff will also review potential parking spill-over into adjacent areas through review of security footage and/or site observations. Maximum Number of Vehicles & Monitoring A maximum total number of vehicles will be allowed per apartment, with the below requirements:  Maximum of 1 parking space for a studio or 1-bedroom apartment  Maximum of 2 parking spaces for a 2-bedroom apartment The number of remaining parking spaces available at the property will be monitored during lease up and stabilization. If there are not a sufficient number of available spaces for a potential resident’s vehicles, a lease will not be executed for that prospective tenant. Additional Parking Language The parking rules will include the below requirements:  All resident vehicles must be registered with management  No unregistered vehicles shall be parked on site  Open parking shall be on a first-come, first-serve basis  Residents with an assigned parking space shall only park in that space, and shall not share the parking space with any other vehicle Brian Jacobson March 29, 2022 Page 9 of 9  Resident guests shall park on site, on a first come first serve basis in the open spaces  Residents and guests may have their vehicle towed at their own expense if they do not have the appropriate parking permit displayed  Residents may be non-renewed if parking rules and regulations are repeatedly violated.  If a resident’s vehicle information changes, it is his/her responsibility to notify management in writing in accordance with the lease agreement. Failure to do so could result in the vehicle being towed at the owner’s expense. TABLE 1 PARKING SUPPLY FOR HAVEST AT TERRA VISTA COMMERICAL USES Location Supply Parking Structure Lower Level 85 spaces Surface Parking 35 spaces Shared Surface Parking 37 spaces Total 157 spaces TABLE 2 CITY OF RANCHO CUCAMONGA PARKING RATES FOR PROJECT AND EXISTING COMMERCIAL DEVELOPMENT Parking Rate [a] Use Number of Spaces Per Unit Total Size Unit Parking Spaces Required Per Code Project Retail [b]4 1,000 sqft 8,590 sqft 34.36 Restaurant [c]10 1,000 sqft 12,251 sqft 122.51 Total 157 Existing Commercial Development Retail [b]4 1,000 sqft 7,100 sqft 28.4 Restaurant [c]10 1,000 sqft 2,790 sqft 27.9 Fast Food Restaurant [c]10 1,000 sqft 3,500 sqft 35 Total 91 Notes a: Source - Rancho Cucamonga Municipal Code Section 17.60.050 c: Identified as restaurants and lounges in Rancho Cucamonga Municipal Code b: As retail space is less than 25,000 sf, the space has been identified as offices, financial institutions, retail stores in Rancho Cucamonga Municipal Code TABLE 3 CITY OF RANCHO CUCAMONGA PARKING RATES FOR PROJECT WITH URBAN LAND INSTITUTE CUSTOMER AND EMPLOYEE RATIOS Use Customers Employee Total Size Unit Parking Spaces Required Per Code Project Weekday Ratios Retail 3.22 0.78 8,590 sqft 34.36 Restaurant 8.76 1.24 12,251 sqft 122.51 Total 157 Project Weekend Ratios Retail 3.20 0.80 8,590 sqft 34.36 Restaurant 8.77 1.23 12,251 sqft 122.51 Total 157 Existing Commercial Development Weekday Ratios Retail 3.22 0.78 7,100 sqft 28.4 Restaurant 8.76 1.24 2,790 sqft 27.9 Fast Food Restaurant 8.61 1.39 3,500 sqft 35 Total 91 Existing Commercial Development Weekend Ratios Retail 3.20 0.80 7,100 sqft 28.4 Restaurant 8.77 1.23 2,790 sqft 27.9 Fast Food Restaurant 8.64 1.36 3,500 sqft 35 Total 91 TABLE 4 SHARED PARKING MODEL REDUCTION ASSUMPTIONS Mode Adjustment Noncaptive Ratio Weekday Weekend Weekday Weekend Use ULI Land Use Daytime Evening Daytime Evening Daytime Evening Daytime Evening Retail Shopping Center - Customer 0% 0% 0%0%3% 5% 3%5% - Employee 0% 0% 0%0%0% 0% 0%0% Restaurant Family Restaurant - Customer 0% 0% 0%0%0% 0% 0%0% - Employee 0% 0% 0%0%0% 0% 0%0% Fast Food Fast Food Restaurant - Customer 0% 0% 0%0%18% 19% 19%18% - Employee 0% 0% 0%0%0% 0% 0%0% TABLE 5SHARED PARKING MODEL MONTH AND WEEKDAY TIME OF DAY DEMAND ASSUMPTIONSPeak MonthTime-of-Day FactorsUse ULI Land UseDecember 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM 12 PM 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11 PM 12 AMRetail Shopping Center- Customer100% 1% 5% 15% 30% 55% 75% 90% 100% 100% 95% 80% 85% 90% 90% 85% 50% 30% 10% 0%- Employee100% 10% 15% 25% 45% 75% 95% 100% 100% 100% 100% 100% 100% 100% 100% 90% 60% 40% 20% 0%Restaurant Family Restaurant- Customer100% 25% 50% 60% 75% 85% 90% 100% 90% 50% 45% 45% 75% 80% 80% 80% 60% 55% 50% 25%- Employee100% 50% 75% 90% 90% 100% 100% 100% 100% 100% 75% 75% 95% 95% 95% 95% 80% 65% 65% 35%Fast Food Fast Food Restaurant- Customer96% 5% 10% 20% 30% 55% 85% 100% 100% 90% 60% 55% 60% 85% 80% 50% 30% 20% 10% 5%- Employee100% 20% 20% 30% 40% 75% 100% 100% 100% 95% 70% 60% 70% 90% 90% 60% 40% 30% 20% 20% TABLE 6SHARED PARKING MODEL MONTH AND WEEKEND TIME OF DAY DEMAND ASSUMPTIONSPeak MonthTime-of-Day FactorsUse ULI Land UseDecember 6 AM 7 AM 8 AM 9 AM 10 AM 11 AM 12 PM 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11 PM 12 AMRetail Shopping Center- Customer100% 1% 5% 10% 35% 60% 85% 100% 100% 100% 100% 90% 80% 65% 60% 55% 50% 35% 15% 1%- Employee100% 10% 15% 40% 75% 85% 95% 100% 100% 100% 100% 100% 95% 85% 80% 75% 65% 45% 15% 0%Restaurant Family Restaurant- Customer100% 10% 25% 45% 70% 90% 90% 100% 85% 65% 40% 45% 60% 70% 70% 65% 30% 25% 15% 10%- Employee100% 50% 75% 90% 90% 100% 100% 100% 100% 100% 75% 75% 95% 95% 95% 95% 80% 65% 65% 35%Fast Food Fast Food Restaurant- Customer96% 5% 10% 20% 30% 55% 85% 100% 100% 90% 60% 55% 60% 85% 80% 50% 30% 20% 10% 5%- Employee100% 15% 20% 30% 40% 75% 100% 100% 100% 95% 70% 60% 70% 90% 90% 60% 40% 30% 20% 20% TABLE 7SHARED PARKING DEMAND SUMMARY - EXISTING COMMERICAL DEVELOPMENTULI SHARED PARKING RATESPEAK MONTH: DECEMBER -- PEAK PERIOD: 12 PM, WEEKENDQuantityUnit1 PM December 12 PM DecemberRetail (<400 ksf)7,100 sf GLA 3.22 100% 99% 3.20 ksf GLA 3.20 100% 99% 3.18 ksf GLA 100% 100%21100% 100%23Employee0.78 100% 100% 0.78 0.80 100% 100% 0.80 100% 100%6100% 100%6Family Restaurant2,790 sf GLA 8.76 100% 98% 8.58 ksf GLA 8.77 100% 98% 8.63 ksf GLA 90% 100%25100% 100%25Employee1.24 100% 100% 1.24 1.23 100% 100% 1.23 100% 100%4100% 100%4Fast Food Restaurant3,500 sf GLA 8.61 100% 91% 7.84 ksf GLA 8.64 100% 91% 7.87 ksf GLA 100% 96%26100% 96%26Employee1.39 100% 100% 1.39 1.36 100% 100% 1.36 100% 100%5100% 100%571 74151586898% 6%Shared Parking ReductionCustomer CustomerEmployee EmployeeRetailFood and BeverageTotal TotalProject RatioUnit For RatioPeak Hr AdjPeak Mo AdjEstimated Parking DemandPeak Hr AdjNon-Captive RatioProject RatioUnit For RatioBase RatioDriving AdjNon-Captive RatioLand UseProject DataWeekday Weekend Weekday WeekendBase RatioDriving AdjPeak Mo AdjEstimated Parking Demand TABLE 8SHARED PARKING DEMAND SUMMARY - PROJECT AND EXISTING COMMERICAL DEVELOPMENTULI SHARED PARKING RATESPEAK MONTH: DECEMBER -- PEAK PERIOD: 12 PM, WEEKENDQuantityUnit1 PM December 12 PM DecemberRetail (<400 ksf)15,690sf GLA 3.22 100% 98% 3.17 ksf GLA 3.20 100% 98% 3.14 ksf GLA 90% 100%45100% 100%50Employee0.78 100% 100% 0.78 0.80 100% 100% 0.80 100% 100%13100% 100%13Family Restaurant15,041 sf GLA 8.76 100% 99% 8.71 ksf GLA 8.77 100% 100% 8.73 ksf GLA 100% 100%131100% 100%131Employee1.24 100% 100% 1.24 1.23 100% 100% 1.23 100% 100%19100% 100%19Fast Food Restaurant3,500 sf GLA 8.61 100% 78% 6.73 ksf GLA 8.64 100% 79% 6.80 ksf GLA 100% 96%21100% 96%21Employee1.39 100% 100% 1.39 1.36 100% 100% 1.36 100% 100%5100% 100%5198 20337372352407% 5%Total TotalShared Parking ReductionCustomer CustomerEmployee EmployeeRetailFood and BeveragePeak Hr AdjPeak Mo AdjEstimated Parking DemandPeak Hr AdjPeak Mo AdjEstimated Parking DemandUnit For RatioBase RatioDriving AdjNon-Captive RatioProject RatioUnit For RatioLand UseProject DataWeekday Weekend Weekday WeekendBase RatioDriving AdjNon-Captive RatioProject Ratio Total Development (Sqft or Rooms) Land-Use6 AM 7 AM 8 AM 9 AM 10 AM 11 AM 12 PM 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11 PM 12 AMPeak Hour Parking Demand15,690 Retail2 4 11 21 37 50 58 63 63 61 53 55 58 58 54 33 20 8 0 5813,791 Restaurant42 80 96 116 131 137 150 137 85 73 73 117 123 123 123 94 85 78 40 1384,750 Fast Food23681523262624161516222113863238Total 44 82 107 139 179 209 234 227 175 152 142 186 204 203 187 132 106 84 39TABLE 9ULI SHARED PARKING RATESPEAK PARKING DEMAND DISTRIBUTION (WEEKDAY)448210713917920923422717515214218620420318713210684390501001502002506 AM 7 AM 8 AM 9 AM 10 AM 11 AM 12 PM 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11 PM 12 AMPeak Parking Demand Distribution ‐WeekdayRetailRestaurantFast FoodTotalRetail, 58Restaurant, 138Fast Food, 38Peak Hour Parking Demand ‐Weekday Total Development (Sqft or Rooms) Land-Use6 AM 7 AM 8 AM 9 AM 10 AM 11 AM 12 PM 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11 PM 12 AMPeak Hour Parking Demand15,690 Retail2 4 10 27 41 55 63 63 63 63 58 52 43 40 37 33 23 9 0 6313,791 Restaurant23 47 76 109 137 137 150 131 104 67 73 97 110 110 104 55 45 32 20 1374,750 Fast Food23681523262624161517232214963239Total 26 52 87 139 189 214 239 221 193 148 147 164 178 173 151 95 73 43 21TABLE 10ULI SHARED PARKING RATESPEAK PARKING DEMAND DISTRIBUTION (WEEKEND)265287139189214239221193148147164178173151957343210501001502002506 AM 7 AM 8 AM 9 AM 10 AM 11 AM 12 PM 1 PM 2 PM 3 PM 4 PM 5 PM 6 PM 7 PM 8 PM 9 PM 10 PM 11 PM 12 AMPeak Parking Demand Distribution ‐WeekendRetailRestaurantFast FoodTotalRetail, 63Restaurant, 137Fast Food, 39Peak Hour Parking Demand ‐Weekend 197197219212222216217219204212211235220050100150200250January February March April May June July August September October November December LateDecemberPeak Parking DemandWeekday Parking DemandFigure 1 195195218210220215216217202210209240216050100150200250January February March April May June July August September October November December LateDecemberPeak Parking DemandWeekend Parking DemandFigure 2 CHURCH STREETFOOTHILL BOULEVARDELM STREET MILLIKENAVENUE24'26'26'26'26'26'26'26'33'26'24'26'26' 24'26'26'26'26'26'26'44'44'67' 65'26'26'24'26'24'26'26'24'26' 26' 118'R=185' L=36'N0°08'55"W 252'N89°51'05"E 250'R=2934'L=176'N0°14'48"W 97'13 '6=2R=24' L=36'214'N89°51'05"E 126'N89°51'05"E55'N0°08'55"W 247' =2 29R3L=14'N58°48'01"W26'R=3050'R'R=2938'L=39'N04°57'42"E4'=R196L=218'R=1044' L=34'N0°08'55"W 279'N05°43'09"E5'R=24' L=38'R=2936' L=21'N5°33'50"W 196'=0'L='N77°43'56"E4''4R=1516'L=159'R=192' L=37'R = 2931'AAAAAAAAAAAAAAAAAAAAABAAAAAAAAAAAAAGAS STATION(N.A.P.)LOT 4P.M. 15424(N.A.P.)PARCEL 3LOT 3LOT 2N89°51'05"E26'L=57'R=161'L=30'R=85'N89°51'05"E71'N01°41'24"E N00°08'55"W 32'N41°00'06"E N11°56'39"W 6'N78°03'21"E880'L=41'N83°58'58"W 136'L N85°35'40"E 5'84LOT 1N89°51'05"E 145'N89°51'05"E32'L=52'R=214'L=73'R=143'N89°09'59"E32'N87°15'01"E50'N89°01'22"E91'L=3'R=50'N0°00'15"E 211'R=20' L=11'R=47' L=61'N08°56'36"W 137'N78°03'21"E1052'N00°25'08"W17'L=30'L=156'526'526'INGRESS / EGRESS(TYPICAL)INGRESS / EGRESS(TYPICAL)INGRESS / EGRESS(TYPICAL)60'N12°33'31"W29.80'EXIST. R.O.W.EXIST. R.O.W.EXIST. R.O.W.EXIST. R.O.W.EXIST. R.O.W.EXIST. R.O.W.EXIST. R .O .W .EXIST. R.O.W.EXIST. R.O.W.EXIST. R.O.W.PROPERTY L INEPROPERTY L INE PROPERTY LINEPROPERTY LINE PROPERTY LINE PROPERTY LINEPROPERTY LINE PROPERTY LINEPROPERTY LINEPROPERTY LINE PROPERTY LINELINEPROPERTY(5.69 AC)R=2938'(1.71 AC)(1.69 AC)(9.47 AC)50'94'60'127' 116'50'94'79'69'148'66'126'64'66'130'44'50'94'44'44'88'PROP. STORM DRAINPROP.SEWERPROP.WATER PROP. STORM DRAINPROP.SEWERPROP.WATERPROP.SEWERPROP.WATERPROP.SEWERPROP.WATERPROP.SEWERPROP.WATERPROP.SEWERPROP.WATERPROP.SEWERPROP.WATERPROP. STORM DRA IN PROP. STORM DRA IN PROP. STORM DRA INPROP. STORM DRAINPROP.SEWERPROP.SEWER DCULTIMATE R.O.W .ADDITIONAL5'DEDICATIONULTIMATE R.O.W .L=39'ULTIMATE R.O.W.(0.10 AC)EXIST. R.O.W. ADD'LDEDIC. VARIES 5'49'93'26'24'26'26'CL60'60' 120' 70'60' 130' 147.5' 125' 60'65' 22.5' 60' 142.5'DEDICAT IONADDIT IONALBVACATIONEXIST. R / W(0.10 AC)DEDICAT IONADDIT IONALB49'(0.01 AC)ESEE DETAIL"A" ABOVE50'66' 26.5' 117' 50' 67'VARIES139'70'69'(0.32 AC)DEDICATIONADDITIONALB(0.01 AC)EEXIST. R.O.W. 6'5'1'R=3050'L=218'R=3049'L=217'N78°03'21"EN11°56'39"WN78°03'21"EULTIMATE R / WEXIST. R / W VACATION32'N41°00'06"E 33'N41°00'06"E AO ARCHITECTS144 NORTH ORANGE ST.ORANGE, CA 92866CONTACT:(714) 639-9860Email: @aoarchitects.comARCHITECTIN THE CITY OF RANCHO CUCAMONGA, COUNTY OF SAN BERNARDINOSTATE OF CALIFORNIAJANUARY, 202218.99 AC. GROSS TENTATIVE TRACT NO. 20120BEING A SUBDIVISION OF PARCEL 1, 2, 4 AND 5 OF PARCEL MAP No. 15424, AS PER PLATRECORDED IN BOOK 191, PAGES 46 THROUGH 48 AND OF PARCEL 1 OF PARCEL MAP NO.15455, AS PER PLAT RECORDED IN BOOK 191, PAGES 33 THROUGH 35, BOTH OF PARCEL MAPS,IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.18.56 AC. NETAPN: 1077-422-51,52,54,55 AND 1090-121-28(198 UNITS FOR CONDOMINIUM PURPOSES)1. PRESENT ZONING: PC-TV2. LAND USE PROPOSED - MIXED USE3. THIS SITE CONTAINS 18.99 GROSS ACRES.4. THIS SITE CONTAINS 18.62 NET ACRES.5. THIS SITE CONSISTS OF (3) NUMBERED LOTS6. THIS SITE CONTAINS 2 LETTERED LOTS7. CONTOURS FROM MADOLE & ASSOCIATES, INC.DATED: 03/27/20208. SEWAGE DISPOSAL CUCAMONGA VALLEY WATERDISTRICT.9. EXISTING IMPERVIOUS AREA TBD ACRES.10. PROPOSED IMPERVIOUS AREA TBD ACRES.NTSVICINITY MAPMILLIKEN CHURCHMAYTEN PROJECT LOCATIONELM FOOTHILLSTREETAVENUE AVENUEEUCALYPTUSSTREET AVENUEBOULEVARDSPRUCE AVENUE VERIZON1400 E. PHILLIPS BLVD.POMONA, CA 91766ATTN: JERRY PAUBELPHONE: (909) 469-6354SOUTHERN CALIFORNIA GAS CO.13525 12th STREETCHINO, CA 91719PHONE: (909) 613-1531UNDERGROUND SERVICE ALERT 811SET 2" BRASS DISK IN CONC. CURBSTAMPED "CITY OF RANCHOCUCAMONGA BM 10054 1987" AT N/ECOR. OF BASELINE ROAD & MILLIKENAVE., AT WEST END OF CATCH BASIN.NO. 10054ELEV.=1328.075UTILITY COMPANIESCUCAMONGA VALLEY WATERDISTRICT10440 ASHFORD STREET P.O. BOX 638RANCHO CUCAMONGA, CA. 91729PHONE: (909) 987-2591SO. CALIFORNIA EDISON COMPANY7951 REDWOOD AVENUEFONTANA, CA. 92336PHONE: (909) 820-5598 UNDERGROUNDPHONE: (909) 875-5100 TRANSMISSIONSPHONE: (213) 637-1233 PIPELINESPHONE: (909) 357-6233 DISTRIBUTIONCONTACT: ISAAC DOMINGUEZPHONE (909) 930-8576 EMAIL:isaac.dominguez@sce.comCIVIL ENGINEEROWNER/DEVELOPERMADOLE & ASSOCIATES, INC.CONSULTING CIVIL ENGINEERS,PLANNERS AND SURVEYORS9302 PITTSBURGH AVENUE, SUITE 230RANCHO CUCAMONGA, CA 91730CONTACT: MARK BERTONE(909) 481-6322 ext. 120Email: mbertone@madoleinc.comWDC COMMONS, LLC1156 N. MOUNTAIN AVEUPLAND, CA. 91786CONTACT: BRIAN JACOBSON(909)579-1214 OFFICEEmail: Brian.Jacobson@lewismc.comSITESCAPES, INC.3190 B-2 AIRPORT LOOP DRIVECOSTA MESA, CA. 92626CONTACT: RICK POLHAMUS(949) 644-9370Email: rpolhamus@sitescapes.netLANDSCAPE ARCHITECTWDCC MILLIKEN WEST RESIDENTIAL, LLC1156 N. MOUNTAIN AVE. UPLAND, CA 91786(909) 985-0971144 NORTH ORANGE ST., ORANGE, CA 92866(714) 639-9860ARCHITECTS ORANGEMADOLE&ASSOCIATES, INC.RANCHO CUCAMONGA, CALIFORNIAHARVEST AT TERRA VISTADATE: JANUARY 10, 2022JOB NO. 126-2647TENTATIVE TRACT MAP TTM-1HALF MEDIAN ---------------- 6'#1 EASTBOUND LANE ------ 11'#2 EASTBOUND LANE ------ 11'BUFFER ------------------------- 3'RAISED CYCLE TRACK ---- 7'URBAN SIDEWALK --------- 11'TOTAL LANE WIDTH -------- 49'CHURCH STREET 49' R / W DIMENSION STRING:DETAIL "A"SCALE: 1" = 20'4 NUMBERED LOTSJ:\126-2647\tentative\TTM01.dwg, 1/10/2022 3:20:20 PM, gbarronExhibit K Design Review Committee Meeting Rains Conference Room AGENDA March 15, 2022 MINUTES Rancho Cucamonga, CA 91730 7:00 p.m. A. Call to Order The meeting of the Design Review Committee was held on March 15, 2022. The meeting was called to order by Mike Smith, Staff Coordinator, at 7:00 p.m. Design Review Committee members present: Diane Williams, Tony Morales Staff Present: Vincent Acuna, Associate Planner B.Public Communications Staff Coordinator opened the public communication and, after noting there were no public comments, closed public communications. C.Consent Calendar C1. Consideration to adopt Regular Meeting Minutes of February 15, 2022. Motion carried 2-0 vote to adopt the minutes as presented. D.Project Review Items D1. LOCATED AT THE NORTHWEST CORNER OF FOOTHILL BOULEVARD AND MILLIKEN AVENUE - WDCC MILLIKEN WEST RESIDENTIAL, LLC - A request to establish a Master Plan and construct a mixed-use development comprising of 671 apartments and 20,841 square feet of commercial space within the Mixed-Use Urban Corridor (MU-UCR) District, APNs: 1077-422-51, -55, -98, -99, 1090-121-38, and -39. (Design Review DRC2021-00120, Tentative Tract Map 20120 (SUBTT00024), and Master Plan DRC2022-00074). The Committee took the following action: Recommend approval to PC/PD. 2-0 Vote Staff made a presentation to the Design Review Committee, followed by a brief presentation by the applicant highlighting project amenities and operations. Both Design Review Committee members were very pleased with the project design, the number of amenities, provided, and the project layout. Committee Member Morales asked about the visibility of the parking structure over the residential wrap building, and if this is a concern for staff. Staff noted that the parking structure protruding beyond the roofline of the residential “wrap” portion of the building is a known issue. Staff requested that the applicant provide a 3D view depicting the parking structure. Based on these renderings, the parking structure visibility will be very minimal. Staff noted that light standards will not be installed on the top level of the parking structure in order to reduce its visibility. Additionally, a Condition of Approval will be added to screen a portion of the Exhibit L Design Review Committee Regular Meeting Minutes – March 15, 2022 Page 2 of 2 Draft parking structure in the event that the Planning Director determines that screening is required while the wrap building is under construction. Both Committee members remarked that the proposed project architecture is refreshing and unique for this area. They both liked that the project was broken down into smaller blocks for easy pedestrian access, and the fact that the project is publicly accessible. The Design Review Committee moved to recommend that project as proposed to the full Planning Commission for consideration. E. Adjournment Meeting was adjourned at 8:05 p.m. Respectfully submitted, ________________________ Elizabeth Thornhill Executive Assistant, Planning Department Approved: Exhibit M – CEQA Section 15183 Compliance Memorandum Due to file size, this attachment can be accessed through the following link: https://www.dropbox.com/sh/py8i3sb3fkd1uty/AABXm-kCUfZV- FIJGAW8xk27a/WDCC%20Milliken%20West%20Residential%20LLC%20- %20Section%2015183%20Compliance%20Memo?dl=0&subfolder_nav_tracking=1 Exhibit M RESOLUTION NO. 22-12 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING TENTATIVE TRACT MAP 20120, A REQUEST TO SUBDIVIDE A VACANT SITE OF APPROXIMATELY 17.2 ACRES INTO 4 NUMBERED LOTS FOR CONDOMINIMUM WITHIN THE MIXED-USE URBAN CORRIDOR (MU-UCR) DISTRICT, LOCATED AT THE NORTHWEST CORNER OF FOOTHILL BOULEVARD AND MILLIKEN AVENUE AND MAKING FINDINGS IN SUPPORT THEREOF - APNS: 1077-422-51, -55, -98, -99, 1090-121-38, AND -39. A.Recitals. 1.WDCC Milliken West Residential, LLC. filed an application for the issuance of Tentative Tract Map 20120 (SUBTT00024), as described in the title of this Resolution. Hereinafter in this Resolution, the subject Tentative Tract Map request is referred to as "the application." 2.On the 27th day of April 2022, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on said application and concluded said hearing on that date. 3.All legal prerequisites prior to the adoption of this Resolution have occurred. B.Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1.This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2.Based upon the substantial evidence presented to this Commission during the above- referenced public hearing on April 27, 2022, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a.The application applies to applies to a vacant site located at the northwest corner of Foothill Boulevard and Milliken Avenue; and b. The project site has an area of approximately 17.2 acres. The project site covers approximately three-fourths of the city block bordered by Elm Avenue to the west, Milliken Avenue to the east, Church Street to the north, and Foothill Boulevard to the south; and c.The existing land uses on, and General Plan land use and zoning designations for, the project site and the surrounding properties (relative to the above-noted) are as follows: Land Use General Plan Zoning Site Vacant City Corridor High Mixed Use - Urban Corridor (MU-UCR) District Exhibit N PLANNING COMMISSION RESOLUTION NO. 22-12 TENTATIVE TRACT MAP 20120 (SUBTT00024) – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 2 d. The proposal is to subdivide a site of approximately 17-2 acres into 4 numbered lots for condominium purposes, in relation to the construction of a mixed-use development comprising of 671 apartment units and 20,841 square feet of commercial space; and e. The project site will have four points of vehicular access from driveways coming from Church Street, Milliken Avenue, Foothill Boulevard, and Elm Avenue. The Engineering Department has included conditions that require the construction of right-of way improvements; and f. This application is in conjunction with Design Review 2021-00120 to construct a mixed-use development comprising of 671 apartment units and 20,841 square feet of commercial space and Master Plan DRC2022-00074 to establish a Master Plan on the project site; and g. The project was reviewed by the Design Review Committee on March 15, 2022. The committee was very supportive of the project architecture, layout, and amenities. The committee voted to move the project forward as presented to the Design Review Committee to the full Planning Commission for consideration; and 3. Based upon the substantial evidence presented to this Commission during the above- referenced public hearing and upon the specific findings of facts set forth in paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The design and layout of the subject Tentative Tract Map will be consistent with the General Plan and the Development Code. The project site is being subdivided to facilitate the development of a mixed-use project which will be consistent with the Mixed-Use zoning of the project site; and b. The site is physically suitable for the subdivision which will create four (4) numbered lots for condominium purposes; and c. The design of the subdivision is not likely to cause substantial environmental damage and avoidable injury to humans and wildlife or their habitat. A CEQA Section 15183 Compliance Memorandum dated March 22, 2022, was prepared by T & B Planning that demonstrates that the subject project is fully consistent with the site’s General Plan land use North Multifamily Residential Suburban Neighborhood Moderate Medium High (MH) Residential 1 South Shopping Center (north and south of Foothill) City Corridor High Financial, Restaurants, Residential (MFC)1 north of Foothill and Industrial Park (IP) south of Foothill East Hospital/ Partially Vacant City Corridor High Hospital and Related Facilities, Office (MHO)1 West Shopping Center City Corridor High Community Commercial (CC) District 1 1 – Terra Vista Planned Community PLANNING COMMISSION RESOLUTION NO. 22-12 TENTATIVE TRACT MAP 20120 (SUBTT00024) – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 3 designation of “City Corridor – High”, consistent with all applicable General Plan policies, and is within the scope of the EIR certified as part of the City’s General Plan update on December 15, 2021. d. The tentative tract map is not likely to cause serious public health problems. The tentative map is proposed in conjunction with a mixed-use development comprising of 671 apartment units and 20,841 square feet of commercial space. A CEQA Section 15183 Compliance Memorandum dated March 22, 2022, was prepared by T & B Planning that demonstrates that the subject project is fully consistent with the site’s General Plan land use designation of “City Corridor – High”, consistent with all applicable General Plan policies, and is within the scope of the EIR certified as part of the City’s General Plan update on December 15, 2021. e. The design of the tentative tract will not conflict with any easement acquired by the public at large, now of record, for access through or use of the property within the proposed subdivision. Access to the property will be from existing public streets surrounding the project site and access to the individual future development will be from private streets to be constructed on the subject property. 4. Based upon the facts and information contained in the CEQA Guidelines Section 15183 Compliance Memorandum, together with all written and oral reports included for the environmental assessment for the application, the Planning Commission finds that there is no substantial evidence that the project will have a significant effect upon the environment based upon the findings as follows: a. The City of Rancho Cucamonga adopted a comprehensive update to the City’s General Plan (GPU) and certified a Program Environmental Impact Report (EIR) (SCH No. 2021050261) on December 15, 2021. As part of the GPU, the Project site was designated for “City Corridor – High” land uses, which allows for residential development at densities ranging from 36 to 60 dwelling units per acre (du/ac) and non-residential development at a Floor Area Ratio (FAR) ranging from 0.6 to 1.5. According to Section 15168 of the CEQA Guidelines, a Program EIR may be prepared on a series of actions that can be characterized as one large project. Use of a Program EIR gives the Lead Agency an opportunity to consider broad policy alternatives and program-wide mitigation measures, as well as greater flexibility to address project-specific and cumulative environmental impacts on a comprehensive scale. b. Pursuant to Section 15183(c) of the State CEQA Guidelines, “if an impact is not peculiar to the parcel or to the project, has been addressed as a significant effect in the prior EIR, or can be substantially mitigated by the imposition of uniformly applied development policies or standards…then an additional EIR need not be prepared for the project solely on the basis of that impact.” The 17.2-acre property is designated by the City’s General Plan for “City Corridor – High” land uses. The GPU EIR assumed the Project site would be developed with 722 multi-family residential dwelling units and 337,154 square feet of commercial retail land uses. The proposed Project is fully consistent with the site’s GPU land use designation of “City Corridor – High” and would be consistent with all applicable GPU policies. Therefore, no subsequent or supplemental EIR is required for the proposed project. To demonstrate that no subsequent EIR or environmental review is required, a CEQA Section 15183 Compliance Memorandum dated March 22, 2022, was prepared by T & B Planning. Staff evaluated this memorandum and concluded that the project is within the scope of the EIR certified as part of the City’s GPU on December 15, 2021. The project PLANNING COMMISSION RESOLUTION NO. 22-12 TENTATIVE TRACT MAP 20120 (SUBTT00024) – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 4 will not have one or more significant effects not discussed in the GPU EIR, nor have more severe effects than previously analyzed, and that additional or different mitigation measures are not required to reduce the impacts of the project to a level of less than significant. 5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth in the attached Conditions of Approval. 6. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 27TH DAY OF APRIL 2022 PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: Bryan Dopp, Chairman ATTEST: Matthew R. Burris, Secretary, AICP, LEED AP I, Matthew R. Burris, Secretary, AICP, LEED AP, of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 27th day of April 2022, by the following vote-to-wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS: RESOLUTION NO. 22-11 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING DESIGN REVIEW DRC2021-00120, A REQUEST TO CONSTRUCT A MIXED-USE DEVELOPMENT COMPRISING OF 671 APARTMENTS AND 20,841 SQUARE FEET OF COMMERCIAL SPACE WITHIN THE MIXED-USE URBAN CORRIDOR (MU-UCR) DISTRICT, LOCATED AT THE NORTHWEST CORNER OF FOOTHILL BOULEVARD AND MILLIKEN AVENUE AND MAKING FINDINGS IN SUPPORT THEREOF - APNs: 1077-422-51, -55, -98, -99, 1090-121-38, and -39. A.Recitals. 1.WDCC Milliken West Residential, LLC filed an application for the issuance of Design Review DRC2021-00120, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Design Review request is referred to as "the application." 2.On the 27th day of April 2022, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on said application and concluded said hearing on that date. 3.All legal prerequisites prior to the adoption of this Resolution have occurred. A.Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1.This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2.Based upon the substantial evidence presented to this Commission during the above-referenced public hearing on April 27, 2022, including written and oral staff reports, this Commission hereby specifically finds as follows: a.The application applies to a vacant site located at the northwest corner of Foothill Boulevard and Milliken Avenue; and b.The project site has an area of approximately 17.2 acres. The project site covers approximately three-fourths of the city block bordered by Elm Avenue to the west, Milliken Avenue to the east, Church Street to the north, and Foothill Boulevard to the south; and c.The existing land uses on, and General Plan land use and zoning designations for the project site and the surrounding properties (relative to the above-noted site) are as follows: Land Use General Plan Zoning Site Vacant City Corridor High Mixed Use - Urban Corridor (MU-UCR) District North Multifamily Residential Suburban Neighborhood Medium High (MH) Residential 1 Exhibit O PLANNING COMMISSION RESOLUTION NO. 22-11 DESIGN REVIEW DRC2021-00120 – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 2 d. The proposed project consists of the construction a mixed-use development comprising of 671 apartments and 20,841 square feet of commercial space; and e. This application is in conjunction with Tentative Tract Map 20120 (SUBTT00024) to subdivide the property into 4 numbered lots for condominium purposes and Master Plan DRC2022-00074 to establish a Master Plan on the project site; and f. The project was reviewed by the Design Review Committee on March 15, 2022. The committee was very supportive of the project architecture, layout, and amenities. The committee voted to move the project forward as presented to the Design Review Committee to the full Planning Commission for consideration; and 3. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing and upon the specific findings of facts set forth in Paragraphs 1 and 2 above, this Commission hereby specifically finds and concludes as follows: a. The proposed development is consistent with the General Plan. The General Plan Designation for the project site is City Corridor High, which envisions high development intensities along Foothill Boulevard, particularly adjacent to city centers. The project proposes a total of 671 apartments and 20,841 square feet of commercial space with a density of 36 dwelling units per acre, which is consistent with the General Plan’s vision; and b. The proposed development is in accord with the objectives of the Development Code, and the purposes of the district in which the site is located. The project site is within the Mixed-Use Urban Corridor (MU-UCR) District, which is an area for a mix of residential and nonresidential uses of medium to high intensity, and where a vibrant pedestrian environment and transition in scale to surrounding neighborhoods are achieved. The project provides for a proper mix of residential and commercial uses, concentrating pedestrian activity and intensity along Foothill Boulevard while transitioning building scale appropriately to the surrounding area; and c. The proposed development complies with each of the applicable provisions of the Development Code. As allowed in the Development Code, the project is being proposed in conjunction with a Master Plan, which allows for a coordinated, comprehensive planning of a subarea of the city, in order to develop an exceptional project design that cannot be built due to constraints in existing development standards. The master plan will provide flexibility in two areas: setbacks and minimum building height, that is primarily applicable to the walk-up residential units Moderate South Shopping Center (north and south of Foothill) City Corridor High Financial, Restaurants, Residential (MFC)1 north of Foothill and Industrial Park (IP) south of Foothill East Hospital/ Partially Vacant City Corridor High Hospital and Related Facilities, Office (MHO)1 West Shopping Center City Corridor High Community Commercial (CC) District 1 1 – Terra Vista Planned Community PLANNING COMMISSION RESOLUTION NO. 22-11 DESIGN REVIEW DRC2021-00120 – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 3 along Church Street and a portion of Milliken Avenue. Aside from these minor deviations that the master plan can accommodate, the project complies with the remaining applicable provisions of the development code; and d. The proposed development, together with the conditions applicable thereto, will not be detrimental to the public health, safety or welfare, or materially injurious to properties or improvements in the vicinity. The project site is vacant; the proposed land use is consistent with the General Plan’s vision for Foothill Boulevard and the expectations of the community. 4. Based upon the facts and information contained in the CEQA Guidelines Section 15183 Compliance Memorandum, together with all written and oral reports included for the environmental assessment for the application, the Planning Commission finds that there is no substantial evidence that the project will have a significant effect upon the environment based upon the findings as follows: a. The City of Rancho Cucamonga adopted a comprehensive update to the City’s General Plan (GPU) and certified a Program Environmental Impact Report (EIR) (SCH No. 2021050261) on December 15, 2021. As part of the GPU, the Project site was designated for “City Corridor – High” land uses, which allows for residential development at densities ranging from 36 to 60 dwelling units per acre (du/ac) and non-residential development at a Floor Area Ratio (FAR) ranging from 0.6 to 1.5. According to Section 15168 of the CEQA Guidelines, a Program EIR may be prepared on a series of actions that can be characterized as one large project. Use of a Program EIR gives the Lead Agency an opportunity to consider broad policy alternatives and program-wide mitigation measures, as well as greater flexibility to address project-specific and cumulative environmental impacts on a comprehensive scale. b. Pursuant to Section 15183(c) of the State CEQA Guidelines, “if an impact is not peculiar to the parcel or to the project, has been addressed as a significant effect in the prior EIR, or can be substantially mitigated by the imposition of uniformly applied development policies or standards…then an additional EIR need not be prepared for the project solely on the basis of that impact.” The 17.2-acre property is designated by the City’s General Plan for “City Corridor – High” land uses. The GPU EIR assumed the Project site would be developed with 722 multi-family residential dwelling units and 337,154 square feet of commercial retail land uses. The proposed Project is fully consistent with the site’s GPU land use designation of “City Corridor – High” and would be consistent with all applicable GPU policies. Therefore, no subsequent or supplemental EIR is required for the proposed project. To demonstrate that no subsequent EIR or environmental review is required, a CEQA Section 15183 Compliance Memorandum dated March 22, 2022, was prepared by T & B Planning. Staff evaluated this memorandum and concluded that the project is within the scope of the EIR certified as part of the City’s GPU on December 15, 2021. The project will not have one or more significant effects not discussed in the GPU EIR, nor have more severe effects than previously analyzed, and that additional or different mitigation measures are not required to reduce the impacts of the project to a level of less than significant. 5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth in the attached Conditions of Approval. 6. The Secretary to this Commission shall certify to the adoption of this Resolution. PLANNING COMMISSION RESOLUTION NO. 22-11 DESIGN REVIEW DRC2021-00120 – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 4 APPROVED AND ADOPTED THIS 27TH DAY OF APRIL 2022. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: Bryan Dopp, Chairman ATTEST: Matthew R. Burris, Secretary, AICP, LEED AP I, Matthew R. Burris, Secretary, AICP, LEED AP, of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 27th day of April 2022, by the following vote-to-wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS: RESOLUTION NO. 22-10 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, RECOMMENDING APPROVAL OF MASTER PLAN DRC2022-00074, A REQUEST TO ESTABLISH A MASTER PLAN FOR A VACANT SITE OF APPROXIMATELY 17.2 ACRES LOCATED AT THE NORTHWEST CORNER OF FOOTHILL BOULEVARD AND MILLIKEN AVENUE AND MAKING FINDINGS IN SUPPORT THEREOF - APNS: 1077-422-51, -55, -98, -99, 1090-121-38, AND -39. A.Recitals. 1.WDCC Milliken West Residential, LLC filed an application for the issuance of Master Plan DRC2022-00074, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Master Plan application request is referred to as "the application." 2.On the 27th day of April 2022, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on said application and concluded said hearing on that date. 3.All legal prerequisites prior to the adoption of this Resolution have occurred. B.Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1.This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2.Based upon the substantial evidence presented to this Commission during the above- referenced public hearing on April 27, 2022, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a.The application applies to a vacant site located at the northwest corner of Foothill Boulevard and Milliken Avenue; and b.The project site for the application has an area of approximately 17.2 acres. The project site covers approximately three-fourths of the city block bordered by Elm Avenue to the west, Milliken Avenue to the east, Church Street to the north, and Foothill Boulevard to the south; and c.The existing land uses on, and General Plan land use and zoning designations for the project site and the surrounding properties (relative to the above-noted) are as follows: Land Use General Plan Zoning Site Vacant City Corridor High Mixed Use - Urban Corridor (MU-UCR) District North Multifamily Residential Suburban Neighborhood Medium High (MH) Residential 1 Exhibit P PLANNING COMMISSION RESOLUTION NO. 22-10 MASTER PLAN DRC2022-00074 – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 2 d. The proposal is to establish a Master Plan creating unique development standards for the project site in order to enable a mixed-use development of 671 apartment units and 20,841 square feet of commercial space; and e. This application is in conjunction with Tentative Tract Map 20120 (SUBTT00024) to subdivide the property into 4 numbered lots for condominium purposes and Design Review DRC2021-00120 to construct a mixed-use development comprising of 671 apartment units and 20,841 square feet of commercial space; and f. The project was reviewed by the Design Review Committee on March 15, 2022. The committee was very supportive of the project architecture, layout, and amenities. The committee voted to move the project forward as presented to the Design Review Committee to the full Planning Commission for consideration; and 3. Based upon the substantial evidence presented to this Commission during the above- referenced public hearing and upon the specific findings of facts set forth in paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The proposed Master Plan is consistent with the goals, policies, and objectives of the General Plan. The site has a General Plan designation of City Corridor High, which envisions high development intensities along Foothill Boulevard, particularly adjacent to city centers. The proposed Master Plan enables the development of Design Review DRC2021-00120, which is a mixed-use project comprising of 671 apartment units and 20,841 square feet of commercial space. The design and layout of this development is consistent with the General Plan goals, policies, and objectives for the project site. However, the development cannot be built under the existing development standards due to unique project characteristics, which themselves effectively implement the vision of the General Plan. The Master Plan application allows for the flexibility to allow the development project as proposed beyond what would be allowed under the conventional zoning district; and b. The proposed Master plan meets the applicable requirements set forth in Chapter 17.22.020 of the Rancho Cucamonga Municipal Code. The proposed Master Plan application meets the purpose and intent of a Master Plan as discussed in the development code. Furthermore, the Master plan document contains all required sections as outlined in Chapter 17.22.020 of the Rancho Cucamonga Municipal Code. Moderate South Shopping Center (north and south of Foothill) City Corridor High Financial, Restaurants, Residential (MFC)1 north of Foothill and Industrial Park (IP) south of Foothill East Hospital/ Partially Vacant City Corridor High Hospital and Related Facilities, Office (MHO)1 West Shopping Center City Corridor High Community Commercial (CC) District 1 1 – Terra Vista Planned Community PLANNING COMMISSION RESOLUTION NO. 22-10 MASTER PLAN DRC2022-00074 – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 3 4. Based upon the facts and information contained in the CEQA Guidelines Section 15183 Compliance Memorandum, together with all written and oral reports included for the environmental assessment for the application, the Planning Commission finds that there is no substantial evidence that the project will have a significant effect upon the environment based upon the findings as follows: a. The City of Rancho Cucamonga adopted a comprehensive update to the City’s General Plan (GPU) and certified a Program Environmental Impact Report (EIR) (SCH No. 2021050261) on December 15, 2021. As part of the GPU, the Project site was designated for “City Corridor – High” land uses, which allows for residential development at densities ranging from 36 to 60 dwelling units per acre (du/ac) and non-residential development at a Floor Area Ratio (FAR) ranging from 0.6 to 1.5. According to Section 15168 of the CEQA Guidelines, a Program EIR may be prepared on a series of actions that can be characterized as one large project. Use of a Program EIR gives the Lead Agency an opportunity to consider broad policy alternatives and program-wide mitigation measures, as well as greater flexibility to address project-specific and cumulative environmental impacts on a comprehensive scale. b. Pursuant to Section 15183(c) of the State CEQA Guidelines, “if an impact is not peculiar to the parcel or to the project, has been addressed as a significant effect in the prior EIR, or can be substantially mitigated by the imposition of uniformly applied development policies or standards…then an additional EIR need not be prepared for the project solely on the basis of that impact.” The 17.2-acre property is designated by the City’s General Plan for “City Corridor – High” land uses. The GPU EIR assumed the Project site would be developed with 722 multi-family residential dwelling units and 337,154 square feet of commercial retail land uses. The proposed Project is fully consistent with the site’s GPU land use designation of “City Corridor – High” and would be consistent with all applicable GPU policies. Therefore, no subsequent or supplemental EIR is required for the proposed project. To demonstrate that no subsequent EIR or environmental review is required, a CEQA Section 15183 Compliance Memorandum dated March 22, 2022, was prepared by T & B Planning. Staff evaluated this memorandum and concluded that the project is within the scope of the EIR certified as part of the City’s GPU on December 15, 2021. The project will not have one or more significant effects not discussed in the GPU EIR, nor have more severe effects than previously analyzed, and that additional or different mitigation measures are not required to reduce the impacts of the project to a level of less than significant. 5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above, this Commission hereby recommends approval of Master Plan DRC2022-00074 as depicted on Exhibit B, attached hereto. 6. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 27TH DAY OF APRIL 2022. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: Bryan Dopp, Chairman PLANNING COMMISSION RESOLUTION NO. 22-10 MASTER PLAN DRC2022-00074 – WDCC MILLIKEN WEST RESIDENTIAL, LLC April 27, 2022 Page 4 ATTEST: Matthew R. Burris, Secretary, AICP, LEED AP I, Matthew R. Burris, Secretary, AICP, LEED AP, of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 27th day of April 2022, by the following vote-to-wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS: Conditions of Approval Community Development Department Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Please be advised of the following Special Conditions All off-site advertisement for the project is prohibited Citywide unless approval is granted by the Planning Director. 1. Occupancy for the walk-up product shall be limited to 65% (212 units) until a building permit is obtained by the developer and construction has commenced on the wrap building. Subsequently, occupancy for the walk-up product shall be limited to 80% (294 units) until at least 50% of the non-residential portion of the wrap building has been built and tenanted. The developer shall provide the City with copies of commercial leases to demonstrate compliance with this requirement. Finally, no occupancy shall be granted on any residential units on the wrap building until all non -residential spaces on the wrap building has been built and tenanted. The developer shall provide the City with copies of commercial leases to demonstrate compliance with this requirement. 2. The project shall remain in compliance with the parking management plan at all times. In the event of any observed parking violations to the parking management plan, the City reserves the right to require the preparation of off-site, on-street parking restrictions such as, but not limited to, no parking signage, time-limit parking signage, red curb, any necessary street repairs /improvements, or the establishment of the parking district at the cost of the property owner/developer. 3. Developer shall include photometric plans on the building plan check set, for Planning Department review and approval. Please be aware that pedestrian level lighting along the project perimeter may be required by the Planning Department during this time. 4. The developer/contractor shall schedule a Planning Inspection when construction of the 4-story residential wrap building reaches the roof sheathing stage to allow the Planning Department to verify adequate screening of the parking structure has been achieved. The developer /contractor. shall also conduct a height survey to verify the height of the parking structure and four -story wrap building is consistent with the approved plans. As a result of the inspection and /or height survey, the Planning Department may require additional screening and /or enhancements to minimize or reduce the visibility of the parking structure from the public view, including, but not limited to structural additions, painting, and/or installation of veneers along the edge of the parking structure, among others, in a manner that is acceptable to the Planning Director or designee. 5. Prior to the issuance of the building permit for the four -story wrap building, the developer shall provide the Planning Department a recorded document that memorializes a shared parking agreement between the project and the Terra Vista Commons shopping center located at the Northeast corner of Foothill Boulevard and Elm Avenue. The shared parking agreement shall specifically note the number of stalls shared between the Terra Vista Commons shopping center and the project, per the project ’s parking management plan, and the parking plan sheet included in the approved plans. 6. www.CityofRC.us Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval All roof appurtenances, including air conditioners and other roof mounted equipment and /or projections shall be screened from all sides and the sound shall be buffered from adjacent properties and streets as required by the Planning Department. Such screening shall be architecturally integrated with the building design and constructed to the satisfaction of the Planning Director. Any roof -mounted mechanical equipment and /or ductwork, that projects vertically more than 18 inches above the roof or roof parapet, shall be screened by an architecturally designed enclosure which exhibits a permanent nature with the building design and is detailed consistent with the building. Any roof -mounted mechanical equipment and /or ductwork, that projects vertically less than 18 inches above the roof or roof parapet shall be painted consistent with the color scheme of the building. Details shall be included in building plans. 7. The applicant shall sign the Statement of Agreement and Acceptance of Conditions of Approval provided by the Planning Department. The signed Statement of Agreement and Acceptance of Conditions of Approval shall be returned to the Planning Department prior to the submittal of grading/construction plans for plan check, request for a business license, and /or commencement of the approved activity. 8. Copies of the signed Planning Commission Resolution of Approval or Approval Letter, Conditions of Approval, and all environmental mitigations shall be included on the plans (full size). The sheet (s) are for information only to all parties involved in the construction /grading activities and are not required to be wet sealed/stamped by a licensed Engineer/Architect. 9. Crime Free Multi-Family Housing Program - The owner shall cause the manager and any resident manager to complete the training for and enroll the project in the San Bernardino County Crime Free Multi-Family Housing Program. 10. The applicant shall agree to defend at his sole expense any action brought against the City, its agents, officers, or employees, because of the issuance of such approval, or in the alternative, to relinquish such approval. The applicant shall reimburse the City, its agents, officers, or employees, for any Court costs and attorney's fees which the City, its agents, officers, or employees may be required by a court to pay as a result of such action. The City may, at its sole discretion, participate in the defense of any such action but such participation shall not relieve applicant of his obligations under this condition. In the event such a legal action is filed, the City shall estimate its expenses for litigation. The applicant shall deposit such amount with the City or enter into an agreement with the City to pay such expenses as they become due. 11. Any approval shall expire if Building Permits are not issued or approved use has not commenced within 2 years from the date of approval or a time extension has been granted. 12. www.CityofRC.us Page 2 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval This project is subject to public art requirement outlined in Chapter 17.124 of the Development Code . Prior to the issuance of building permits (for grading or construction ), the applicant shall inform the Planning Department of their choice to install public art, donate art or select the in -lieu option as outlined in 17.124.020.D. If the project developer chooses to pay the in -lieu fee, the in-lieu art fee will be invoiced on the building permit by the City and shall be paid by the applicant prior to building permit issuance. If the project developer chooses to install art, they shall submit, during the plan check process, an application for the art work that will be installed on the project site that contains information applicable to the art work in addition to any other information as may be required by the City to adequately evaluate the proposed the art work in accordance with the requirements of Chapter 17.124. If the project developer chooses to donate art, applications for art work donated to the City shall be subject to review by the Public Art Committee which shall make a recommendation whether the proposed donation is consistent with Chapter 17.124 and final acceptance by the City Council. No final approval, such as a final inspection or the a issuance of a Certificate of Occupancy, for any development project (or if a multi-phased project, the final phase of a development project) that is subject to this requirement shall occur unless the public art requirement has been fulfilled to the satisfaction of the Planning Department. 13. This tentative tract map or tentative parcel map shall expire, unless extended by the Planning Commission, unless a complete final map is filed with the Engineering Services Department within 3 years from the date of the approval. 14. For multi-family residential and non -residential development, property owners are responsible for the continual maintenance of all landscaped areas on -site, as well as contiguous planted areas within the public right-of-way. All landscaped areas shall be kept free from weeds and debris and maintained in healthy and thriving condition, and shall receive regular pruning, fertilizing, mowing, and trimming. Any damaged, dead, diseased, or decaying plant material shall be replaced within 30 days from the date of damage. 15. The final design of the perimeter parkways, walls, landscaping, and sidewalks shall be included in the required landscape plans and shall be subject to Planning Director review and approval and coordinated for consistency with any parkway landscaping plan which may be required by the Engineering Services Department. 16. Tree maintenance criteria shall be developed and submitted for Planning Director review and approval prior to issuance of Building Permits. These criteria shall encourage the natural growth characteristics of the selected tree species. 17. Trees shall be planted in areas of public view adjacent to and along structures at a rate of one tree per 30 linear feet of building. 18. www.CityofRC.us Page 3 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval All walls shall be provided with decorative treatment. If located in public maintenance areas, the design shall be coordinated with the Engineering Services Department. 19. Landscaping and irrigation shall be designed to conserve water through the principles of water efficient landscaping per Development Code Chapter 17.82. 20. All parking lot landscape islands shall have a minimum outside dimension of 6 feet.21. All parking spaces shall be double striped per City standards and all driveway aisles, entrances, and exits shall be striped per City standards. 22. The signs indicated on the submitted plans are conceptual only and not a part of this approval. Any signs proposed for this development shall comply with the Sign Ordinance and shall require separate application and approval by the Planning Department prior to installation of any signs. 23. Unless exempt, directory monument sign (s) shall be provided for apartment, condominium, or town homes prior to occupancy and shall require separate application and approval by the Planning Department and the RCFPD prior to issuance of Building Permits for the signs in question. (Chapter 17.74.040 B-4) 24. Approval of this request shall not waive compliance with all sections of the Development Code, all other applicable City Ordinances, and applicable Community, Specific Plans and /or Master Plans in effect at the time of Building Permit issuance. 25. All building numbers and individual units shall be identified in a clear and concise manner, including proper illumination and in conformance with Building and Safety Services Department standards, the Municipal Code and the Rancho Cucamonga Fire Department (RCFD) Standards. 26. The developer shall submit a construction access plan and schedule for the development of all lots for Planning Director and Engineering Services Department approval; including, but not limited to, public notice requirements, special street posting, phone listing for community concerns, hours of construction activity, dust control measures, and security fencing. 27. The site shall be developed and maintained in accordance with the approved plans which include Site Plans, architectural elevations, exterior materials and colors, landscaping, sign program, and grading on file in the Planning Department, the conditions contained herein, the Development Code regulations, and the Harvest at Terra Vista Master Plan. 28. All Double Detector Checks (DDC) and Fire Department Connections (FDC) required and/or proposed shall be installed at locations that are not within direct view or line -of-sight of the main entrance. The specific locations of each DDC and FDC shall require the review and approval of the Planning Department and Fire Construction Services /Fire Department. All Double Detector Checks (DDC) and Fire Department Connections (FDC) shall be screened behind a 4-foot high block wall. These walls shall be constructed of similar material used on-site to match the building. 29. For multiple-family development, provide exterior lockable storage space as required by the California Green Building Code. 30. www.CityofRC.us Page 4 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval All ground-mounted utility appurtenances such as transformers, AC condensers, etc ., shall be located out of public view and adequately screened through the use of a combination of concrete or masonry walls, berming, and/or landscaping to the satisfaction of the Planning Director. For single -family residential developments, transformers shall be placed in underground vaults. 31. A uniform hardscape and street furniture design including seating benches, trash receptacles, free-standing potted plants, bike racks, light bollards, etc ., shall be utilized and be compatible with the architectural style. Detailed designs shall be submitted for Planning Department review and approval prior to the issuance of Building Permits. 32. All parkways, open areas, and landscaping shall be permanently maintained by the property owner, homeowners' association, or other means acceptable to the City. Proof of this landscape maintenance shall be submitted for Planning Director and Engineering Services Department review and approved prior to the issuance of Building Permits. 33. For multiple-family development, laundry facilities shall be provided as required by the Development Code. 34. A detailed on-site lighting plan, including a photometric diagram, shall be reviewed and approved by the Planning Director and Police Department (909-477-2800 ) prior to the issuance of Building Permits . Such plan shall indicate style, illumination, location, height, and method of shielding so as not to adversely affect adjacent properties. 35. Occupancy of the facilities shall not commence until such time as all California Building Code and State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety Services Department to show compliance. The buildings shall be inspected for compliance and final acceptance granted prior to occupancy. 36. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for consistency prior to issuance of any permits (such as grading, tree removal, encroachment, building, etc.) or prior to final map approval in the case of a custom lot subdivision, or approved use has commenced, whichever comes first. 37. Prior to any use of the project site or business activity being commenced thereon, all Conditions of Approval shall be completed to the satisfaction of the Planning Director. 38. Engineering Services Department Please be advised of the following Special Conditions The existing ramps located at the street intersections shall be evaluated for conformance to current ADA regulations. If the ramp does not meet ADA regulations then the developer shall be responsible for providing design and reconstruction of the ramp for compliance . Design shall be completed and improvements secured for prior to issuance of Building permit or approval of final subdivision map whichever occurs first . The reconstruction along with all public improvements shall be completed prior to occupancy. 1. www.CityofRC.us Page 5 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Please be advised of the following Special Conditions The street lights shall be owned by the City. Developer shall be responsible to coordinate and pay all costs of street lights and to provide power to City owned street lights. 2. (DIF Fees): Development impact fees are due prior to issuance of a building permit or certificate of occupancy per the Engineering Fee schedule, Government Code Section 66000, et seq. and local ordinance. Pursuant to Government Code Section 66020(d), the 90-day approval period in which the applicant may protest these fees will begin at the date the fees are invoiced. Protests must be made in writing and be delivered to the City Clerk prior to the close of business on the 90th day of the 90-day approval period. *Note that fees are subject to change annually. 3. RCMU Electric: The Rancho Cucamonga Municipal Utility (RCMU) shall be the electrical service provider for all project related development. The Developer shall execute a Line Extension Agreement for electric service and shall construct electrical distribution facilities in accordance with such agreement and RCMU requirements and dedicate such facilities to the Rancho Cucamonga Municipal Utility. RCMU’s underground electric system is located off of the NEC of Milliken Ave and Foothill Blvd of the proposed development. 4. RCMU Fiber: Fiber Optics - Place 1-4” conduit structure (Mainline) with high-density polyethylene (HDPE) at 18” depth from demarcation location in the public right of way or utility easement dedicated specifically to the Rancho Fiber project. This conduit system will be required to follow the joint trench distribution system within the project where the conduit bank can be installed alongside the Telco and CATV conduits at the proper communication depth. - Place 1-2” conduit structure (Service) with high-density polyethylene (HDPE) directly from mainline pullbox to an 8” round plastic “flower pot” type telecom access box flush mounted to finish grade to serve as a drop access point to city network directly at each individual residence. This drop conduit shall be dedicated for City fiber drop installation only. - An Optical network demarcation enclosure /panel shall be mounted on the side of the home, garage or utility closet for the placement of a Fiber Optic Network Interface Device. Place a #6 solid ground wire placed from network demarcation enclosure to power ground. If no power ground exists a 5/8” x 8” copper clad ground rod is to be installed for ground wire to be connected. RCMU’s underground fiber optic system is located off of the NEC of Milliken Ave and Foothill Blvd of the proposed development. The size, placement and location of the conduit and vaults shall be shown on the Street Improvement and /or Public Improvement Plans and subject to the Engineering Services Department's review and approval prior to the issuance of building permits or final map approval, whichever comes first. 5. www.CityofRC.us Page 6 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Please be advised of the following Special Conditions (In-Lieu Fees for Required Ultimate Improvements): An in-lieu fee as contribution, along the project frontage of Foothill Blvd, shall be required for ultimate public improvements per General Plan that are not constructed at this time. The fee shall be the construction cost of the ultimate improvement items that are not built and subject to the review and approval of the City Engineer. 6. (Traffic Signal Modifications): Traffic signal equipment shall be relocated in accordance to City and Caltrans standard plans and latest ADA requirements. Location of proposed equipment shall be determined during the plan check process. A traffic signal modification plan and signing and striping plan shall be submitted for review and approval. 7. (Proposed Interim Vs. Ultimate Improvements): The developer shall provide a Site Plan showing the proposed interim public improvements and a Site Plan showing the ultimate public improvements. The developer shall also provide design plans for the constructions of the ultimate street improvements along Foothill Blvd, from the centerline of Milliken Blvd to the centerline of Elm Avenue. All public improvement plans shall be provided for review and approval to the Engineering Services Department prior to building permitting or final map approval, whichever comes first. 8. The project Final Map shall meet the Subdivision Map Act, City Development Codes, and Conditions of Approval requirements. The Final Map shall be approved prior to issuance of Building Permits. 9. Standard Conditions of Approval Private drainage easements for cross -lot drainage shall be provided and shall be delineated or noted on the final map. 10. Corner property line cutoffs shall be dedicated per City Standards.11. www.CityofRC.us Page 7 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Standard Conditions of Approval Dedications, street designs, and roadway typologies shall be made per new General Plan as follows and on the following perimeter streets. Foothill Blvd as a Boulevard, Milliken Ave as an Arterial Roadway, Elm Ave as a Collector Street, and Church Street as a Bicycle (Class IV) Corridor. Dedication shall be made of the following rights -of-way on the perimeter streets (measured from street centerline): 87.5 total feet on Foothill Blvd, Varying total feet on Milliken Blvd, 44 total feet on Elm Ave, and 56 total feet on Church Street. 12. All existing easements lying within future rights -of-way shall be quit -claimed or delineated on the final map. 13. Easements for public sidewalks placed outside the public right-of-way shall be dedicated to the City.14. Reciprocal access easements shall be provided ensuring access to all parcels by CC&Rs or by deeds and shall be recorded concurrently with the map or prior to the issuance of Building Permits, where no map is involved. 15. Reciprocal parking agreements for all parcels and maintenance agreements ensuring joint maintenance of all common roads, drives, or parking areas shall be provided by CC & R's or deeds and shall be recorded prior to, or concurrent with, the final parcel map. 16. A final drainage study shall be submitted to and approved by the City Engineer prior to final map approval or the issuance of Building Permits, whichever occurs first. All drainage facilities shall be installed as required by the City Engineer. 17. Trees are prohibited within 5 feet of the outside diameter of any public storm drain pipe measured from the outer edge of a mature tree trunk. 18. www.CityofRC.us Page 8 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Standard Conditions of Approval ** CD Information Required Prior to Sign-Off for Building Permit Prior to the issuance of building permits, if valuation is greater or equal to $100,000, a Diversion Deposit and a related administrative fee shall be paid for the Construction and Demolition Diversion Program. The deposit is fully refundable if at least 65% of all wastes generated during construction and demolition are diverted from landfills, and appropriate documentation is provided to the City. Applicant must identify if they are self -hauling or utilizing Burrtec prior to issuance of a building permit. Proof of diversion must be submitted to the Environmental Engineering Division within 60 days following the completion of the construction and / or demolition project. Contact Marissa Ostos, Environmental Engineering, at (909) 774-4062 for more information. Instructions and forms are available at the City's website, www .cityofrc.us, under City Hall / Engineering / Environmental Programs / Construction & Demolition Diversion Program. 19. Prior to finalization of any development phase, sufficient improvement plans shall be completed beyond the phase boundaries to assure secondary access and drainage protection to the satisfaction of the City Engineer. Phase boundaries shall correspond to lot lines shown on the approved tentative map. 20. A signed consent and waiver form to join and /or form the appropriate Landscape and Lighting Districts shall be filed with the Engineering Services Department prior to final map approval or issuance of Building Permits whichever occurs first. Formation costs shall be borne by the developer. 21. Add the following note to any private landscape plans that show street trees: “All improvements within the public right-of-way, including street trees, shall be installed per the public improvement plans .” If there is a discrepancy between the public and private plans, the street improvement plans will govern. 22. Construct the following perimeter street improvements including, but not limited to: Street Name: Foothill Blvd, Milliken Ave, Church St, Elm Streets Curb & Gutter A.C. Pvmt Side-walk Drive Appr. Street Lights Street Trees Median Island Bike Lanes Cycle Track (Class IV) Etc. Notes: (a) Pavement reconstruction and overlays will be determined during plan check. 23. www.CityofRC.us Page 9 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Standard Conditions of Approval Pursuant to Municipal Code Section 16.37.010, no person shall make connections from a source of energy, fuel or power to any building or structure which is regulated by technical codes and for which a permit is required unless, in addition to any and all other codes, regulations and ordinances, all improvements required by these conditions of development approval have been completed and accepted by the City Council, except: that in developments containing more than one building, structure or unit, the development may have energy connections made in equal proportion to the percentage of completion of all improvements required by these conditions of development approval, as determined by the City Engineer, provided that reasonable, safe and maintainable access to the property exists. In no case shall more than 95 percent of the buildings, structures or units be connected to energy sources prior to completion and acceptance of all improvements required by these conditions of development approval. 24. Improvement Plans and Construction: a. Street improvement plans, including street trees, street lights, and intersection safety lights on future signal poles, and traffic signal plans shall be prepared by a registered Civil Engineer and shall be submitted to and approved by the City Engineer. Security shall be posted and an agreement executed to the satisfaction of the City Engineer and the City Attorney guaranteeing completion of the public and/or private street improvements, prior to final map approval or the issuance of Building Permits, whichever occurs first. b. Prior to any work being performed in public right -of-way, fees shall be paid and a construction permit shall be obtained from the Engineering Services Department in addition to any other permits required. c. Pavement striping, marking, traffic signing, street name signing, traffic signal conduit, and interconnect conduit shall be installed to the satisfaction of the City Engineer. d. Signal conduit with pull boxes shall be installed with any new construction or reconstruction project along major or secondary streets and at intersections for future traffic signals and interconnect wiring . Pull boxes shall be placed on both sides of the street at 3 feet outside of BCR, ECR, or any other locations approved by the City Engineer. Notes: 1) Pull boxes shall be No. 6 at intersections and No. 5 along streets, a maximum of 200 feet apart, unless otherwise specified by the City Engineer. 2) Conduit shall be 3-inch pvc with pull rope or as specified. e. Access ramps for the disabled shall be installed on all corners of intersections per latest ADA standards or as directed by the City Engineer. f. Existing City roads requiring construction shall remain open to traffic at all times with adequate detours during construction. Street or lane closure permits are required. A cash deposit shall be provided to cover the cost of grading and paving, which shall be refunded upon completion of the construction to the satisfaction of the City Engineer. g. Concentrated drainage flows shall not cross sidewalks. Under sidewalk drains shall be installed to City Standards, except for single-family residential lots. 25. www.CityofRC.us Page 10 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Standard Conditions of Approval Install street trees per City street tree design guidelines and standards as follows. The completed legend (box below) and construction notes shall appear on the title page of the street improvement plans. Street improvement plans shall include a line item within the construction legend stating: “Street trees shall be installed per the notes and legend on (typically Sheet 1).” Where public landscape plans are required, tree installation in those areas shall be per the public landscape improvement plans. Street Name: Foothill, Milliken, Church, and Elm Botanical Name: To Be Determined during Plan Check Common Name: To Be Determined during Plan Check Min. Grow Space: To Be Determined during Plan Check Spacing: To Be Determined during Plan Check Size: To Be Determined during Plan Check Qty.: To Be Determined during Plan Check Construction Notes for Street Trees: 1) All street trees are to be planted in accordance with City standard plans. 2) Prior to the commencement of any planting, an agronomic soils report shall be furnished to the City inspector. Any unusual toxicities or nutrient deficiencies may require backfill soil amendments, as determined by the City inspector. 3) All street trees are subject to inspection and acceptance by the Engineering Services Department. Street trees are to be planted per public improvement plans only. 26. Intersection line of sight designs shall be reviewed by the City Engineer for conformance with adopted policy. On collector or larger streets, lines of sight shall be plotted for all project intersections, including driveways. Local residential street intersections and commercial or industrial driveways may have lines of sight plotted as required. 27. All public improvements on the following streets shall be operationally complete prior to the issuance of Building Permits: Foothill Blvd; Milliken Ave; Church St; Elm Street. 28. All public improvements (streets, drainage facilities, interior streets, landscaped areas, etc.) shown on the plans and/or tentative map shall be constructed to City Standards. Interior street improvements shall include, but are not limited to, curb and gutter, AC pavement, drive approaches, sidewalks, street lights, and street trees. 29. Street trees, a minimum of 15-gallon size or larger, shall be installed per City Standards in accordance with the City's street tree program. 30. The developer shall be responsible for the relocation of existing utilities as necessary.31. www.CityofRC.us Page 11 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Engineering Services Department Standard Conditions of Approval Water and sewer plans shall be designed and constructed to meet the requirements of the Cucamonga Valley Water District (CVWD), Rancho Cucamonga Fire Protection District, and the Environmental Health Department of the County of San Bernardino. A letter of compliance from the CVWD is required prior to final map approval or issuance of permits, whichever occurs first. Such letter must have been issued by the water district within 90 days prior to final map approval in the case of subdivision or prior to the issuance of permits in the case of all other residential projects. 32. An easement for a joint use driveway shall be provided prior to final map approval or issuance of Building Permits, whichever occurs first, for: 33. Developer shall execute a Line Extension Agreement for electric service and shall construct electrical distribution facilities in accordance with such agreement and shall construct electrical distribution facilities in accordance with such agreement and Rancho Cucamonga Municipal Utility requirements and dedicate such facilities to the Rancho Cucamonga Municipal Utility. The Rancho Cucamonga Municipal Utility shall be the electrical service provider for all project related development. 34. Fire Prevention / New Construction Unit Standard Conditions of Approval Required alarm systems and supervision systems are required to be in accordance with Fire District Standard 9-3. The Standard has been uploaded to the Documents section. 1. Plans for the alarm and /or supervision (monitoring) system are required to be submitted separately and issued a separate permit. Submit all plans to the Building & Safety Department for routing to the Fire District. 2. Plans for the private, onsite fire underground water infrastructure are required to be submitted separately and issued a separate permit. Submit all plans to the Building & Safety Department for routing to the Fire District. 3. Plans for the public, offsite fire underground water infrastructure are required to be submitted separately and issued a separate permit. Plans are required to be submitted prior to or concurrently with the submittal of the Water District mylars. Submit all plans to the Building & Safety Department for routing to the Fire District. 4. Plans for the automatic fire sprinkler system are required to be submitted separately and issued a separate permit. Submit all plans to the Building & Safety Department for routing to the Fire District. 5. www.CityofRC.us Page 12 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Fire Prevention / New Construction Unit Standard Conditions of Approval Emergency responder radio coverage is required for the building (s) included in this project. San Bernardino County Information Services Department (ISD) conducts radio signal strength assessments for the entire county. It is highly recommended that a radio signal strength assessment is completed for this project. Where emergency responder radio coverage is determined to meet the requirements of the California Fire Code, an emergency responder radio system and /or associated equipment will not be required. Please contact Tim Trager with County ISD at 909-388-5563 or ttrager@isd.sbcounty.gov to schedule an assessment and/or obtain any available information about the project site. Where the existing emergency responder radio coverage is found to be below acceptable standards, an emergency responder radio system and associated equipment will be required to be provided in compliance and accordance with the California Fire Code. 6. Designated and conforming aerial apparatus access is required in accordance with Fire District Standard 5-1. Show aerial apparatus access on the fire access plan. The Standard has been uploaded to the Documents section. 7. Fire apparatus access (fire lane) design, construction, and identification are required to be in accordance with Fire District Standard 5-1. The Standard has been uploaded to the Documents section. 8. Fire extinguishers are required in accordance with Section 906 of the California Fire Code. Consult with the Fire Inspector for the correct type, size, and exact installation locations. 9. Fire flow information for this project is obtained from the Cucamonga Valley Water District (CVWD). CVWD can be reached at 909-944-6000 or custserv@cvwdwater.com. 10. Fire flow is required to be in accordance with Appendix B of the California Fire Code. The Fire District has adopted the appendix without local amendments except that the minimum fire flow for commercial buildings shall not be less than 1500 gpm. Proof of the availability of the required fire flow must be provided to the Fire District in the form of a letter or written report dated within the past 12 months. 11. Fire sprinklers are required to be installed in accordance with Fire District Standard 9-5. The Standard has been uploaded to the Documents section. 12. A Knox Box key box is required in accordance with Fire District Standard 5-9. Additional boxes may be required depending on the size of the building, the location of fire protection and life safety system controls, and the operational needs of the Fire District. The Standard has been uploaded to the Documents section. If an installed Knox Box is available to this project or business, keys for the building/suite/unit are required to be provided to the Fire Inspector at the final inspection. 13. Coordinate landscaping with the roof access ladder points and address signage. Landscaping cannot obstruct roof access or clear visibility of address signage from time of installation to maturity of the shrubs and trees. 14. One or more of the systems, operations, processes, or pieces of equipment associated with this project or the proposed business requires a Fire Code Construction Permit to be issued in accordance with the Fire Code and Fire District Standard 1-2. The Standard has been uploaded to the Documents section. 15. www.CityofRC.us Page 13 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Fire Prevention / New Construction Unit Standard Conditions of Approval A fire service site plan is required in accordance with Fire District Standard 5-11. The Standard has been uploaded to the Documents section. 16. All of the Fire District Standards applicable are required to be reproduced on the plans. The project is required to meet all of the applicable codes, regulations, and standards in effect and adopted at the time of plan check submittal. Fire District Standards associated with construction and plan submittals can be found on the City of Rancho Cucamonga's website and accessed via https://www.dropbox.com/sh/4k4qdxhs4tp13c7/AAAdscMKMdW9WIQe725xWyU-a?dl=0 17. Due to the type of construction, construction materials, the floor area of the project, and known risks associated with projects of this nature, a Fire Protection and Site Safety plan is required to be implemented when combustible construction materials are delivered to the site, with the exception of foundation form materials. The Fire Prevention and Site Safety plan is required to be in compliance with Fire District Standard 33-3. The Standard has been uploaded to the Documents section. Review and approval of the fire prevention and site safety plan is a condition of construction permit approval. The fire prevention and site safety plan is required to be approved by the Fire District prior to construction permits being approved and issued. 18. Roof access is required to be in accordance with Fire District Standard 5-6. The Standard has been uploaded to the Documents section. 19. Street address and unit /suite signage for commercial and industrial buildings are required to be in accordance with Fire District Standard 5-8. The Standard has been uploaded to the Documents section. 20. Identification of fire protection systems and components, fire alarm systems and components, and equipment and devices associated with fire and life safety systems is required to be in accordance with Fire District Standards 5-5 and 5-10. The Standards have been uploaded to the Documents section. 21. A standpipe system is required to be installed in accordance with Section 905 of the Fire Code and Fire District Standard 5-10. The Standard has been uploaded to the Documents section. In addition to the standpipe installations required by Section 905.3, standpipes are required to be installed in the courtyards such that the entire ground floor of all buildings can be reached by a 150-foot hose pull from the standpipes. 22. Street address and unit /suite signage for commercial and industrial buildings are required to be in accordance with Fire District Standard 5-8. The Standard has been uploaded to the Documents section. 23. Fire apparatus access roads and emergency vehicle access is required to be identified with signs and/or other approved makings in accordance with Fire District Standard 5-1. A copy of the Standard has been uploaded to the Documents section. 24. Street address and building identification signage for multi -family residential buildings are required to be in accordance with Fire District Standard 5-7. The Standard has been uploaded to the Documents section. 25. www.CityofRC.us Page 14 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Fire Prevention / New Construction Unit Standard Conditions of Approval Identification of fire protection systems and components, fire alarm systems and components, and equipment and devices associated with fire and life safety systems is required to be in accordance with Fire District Standards 5-5 and 5-10. The Standards have been uploaded to the Documents section. 26. Fire apparatus access roads (fire lanes) can be included in an engineered onsite storm water retention plan. The ponding of storm water shall not exceed a designed depth of four (4) inches in the designated fire apparatus access road (s) and the area between the fire apparatus access road (s) and the exterior walls of all normally occupied buildings. 27. Fire apparatus access roads (fire lanes) can be included in an engineered onsite storm water retention plan. The ponding of storm water shall not exceed a designed depth of four (4) inches in the designated fire apparatus access road (s) and the area between the fire apparatus access road (s) and the exterior walls of all normally occupied buildings. 28. A new public hydrant is required to be installed within 15-50 feet of the Fire Department Connection (FDC) and in accordance with Fire District Standard 5-10. 29. The new connection to the public water main requires the submittal of public, off -site fire underground plans that conform to the standards of the water purveyor and Fire District Standard 5-10. 30. Public and private fire service water mains, public and private hydrants, water control valves, fire sprinkler risers, fire department connections (FDCs), and other fire protection water related devices and equipment are required to be provided, designed, and installed in accordance with Fire District Standard 5-10. The Standard has been uploaded to the Documents section. 31. Building and Safety Services Department Please be advised of the following Special Conditions When the Entitlement Review is approved submit complete construction drawings including structural calculations, energy calculations and soils report to Building and Safety for plan review in accordance with the current edition of the California Building and Fire Codes including all local ordinances and standards which are effective at the time of Plan Check Submittal. The proposed structures are required to be equipped with automatic fire sprinklers per the CBC /CRC NFPA 13, 13D, 13R and the Current RCFPD Ordinance. Disabled access for the site and buildings must be in accordance to the State of California and ADA regulations. A two hour fire rated tunnel is required where the enclosed courtyard exits through the building at the wrap building. Baby changing tables are required in the Clubhouse restrooms as compliant with California State Assembly Bill AB-1127 and the California Building Code. 1. www.CityofRC.us Page 15 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval Prior to issuance of a grading permit for residential projects the applicant shall show on the electrical plans and the permitted grading plan set the location for a future installation of an Electric Vehicle (EV) charging station/parking area per the current adopted California Green Building Standards Code, section 4.106.4. 1. Grading of the subject property shall be in accordance with current adopted California Building Code and/or the California Residential Code, City Grading Standards, and accepted grading practices. The Grading and Drainage Plan (s) shall be in substantial conformance with the approved conceptual Grading and Drainage Plan. 2. A soils report shall be prepared by a qualified Engineer licensed by the State of California to perform such work. Two copies will be provided at grading and drainage plan submittal for review. Plans shall implement design recommendations per said report. 3. The final Grading and Drainage Plan, appropriate certifications and compaction reports shall be completed, submitted, and approved by the Engineering Services Department prior to the issuance of building permits. 4. A separate Grading and Drainage Plan check submittal is required for all new construction projects and for existing buildings where improvements being proposed will generate 50 cubic yards or more of combined cut and fill. The Grading and Drainage Plan shall be prepared, stamped, and wet signed by a California licensed Civil Engineer prior to the issuance of a grading or building permit. 5. The applicant shall comply with the City of Rancho Cucamonga Dust Control Measures and place a dust control sign on the project site prior to the issuance of a grading permit. All dust control sign (s) shall be located outside of the public right of way. 6. If a Rough Grading and Drainage Plan /Permit are submitted to the Engineering Services Department for review, the rough grading plan shall be a separate plan submittal and permit from Precise Grading and Drainage Plan/Permit. 7. Prior to issuance of a grading permit the Final Grading and Drainage Plan shall show the accessibility path from the public right of way and the accessibility parking stalls to the building doors in conformance with the current adopted California Building Code. All accessibility ramps shall show sufficient detail including gradients, elevations, and dimensions and comply with the current adopted California Building Code. 8. The Grading and Drainage Plan shall implement City Standards for on -site construction where possible, and shall provide details for all work not covered by City Standard Drawings. 9. Prior to issuance of a grading permit, the grading and drainage plan shall show the maximum parking stall gradient at 5 percent. Accessibility parking stall grades shall be constructed per the, current adopted California Building Code. 10. The applicant shall provide a grading agreement and grading bond for all cut and fill combined exceeding 5,000 cubic yards prior to issuance of a grading permit. The grading agreement and bond shall be approved by the Engineering Services Department. 11. The final grading and drainage plan shall show existing topography a minimum of 100-feet beyond project boundary. 12. www.CityofRC.us Page 16 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval This project shall comply with the accessibility requirements of the current adopted California Building Code. 13. Grading Inspections: a) Prior to the start of grading operations, the owner and grading contractor shall request a pre -grading meeting. The meeting shall be attended by the project owner /representative, the grading contractor and the Building Inspector to discuss about grading requirements and preventive measures, etc. If a pre-grading meeting is not held within 24 hours from the start of grading operations, the grading permit may be subject to suspension by the Building Inspector; b) The grading contractor shall call into the City of Rancho Cucamonga Building and Safety Department at least 1 working day in advance to request the following grading inspections prior to continuing grading operations: i) The bottom of the over-excavation; ii) Completion of Rough Grading, prior to issuance of the building permit; iii) At the completion of Rough Grading, the grading contractor or owner shall submit to the Permit Technicians (Engineering Services Department Front Counter) an original and a copy of the Pad Certifications to be prepared by and properly wet signed and sealed by the Civil Engineer and Soils Engineer of Record; iv) The rough grading certificates and the compaction reports will be reviewed by the Associate Engineer or a designated person and approved prior to the issuance of a building permit. 14. Prior to issuance of a grading or building permit, the permitted grading plan (or architectural site plan ) set shall show in each of the typical sections and the plan view show how the separations between the building exterior and exterior ground surface meet the requirements of Sections CBC 1804.3/CRC R401.3, CBC2304.11.2.2/CRC R317.1(2) and CBC2512.1.2/CRC R703.6.2.1 of the current adopted California Building Code/Residential Code. 15. Prior to approval of the project -specific storm water quality management plan, the applicant shall submit to the City Engineer, or his designee, a precise grading plan showing the location and elevations of existing topographical features and showing the location and proposed elevations of proposed structures and drainage of the site. 16. A drainage study showing a 100-year, AMC 3 design storm event for on -site drainage shall be prepared and submitted to the Engineering Services Department for review and approval for on -site storm water drainage prior to issuance of a grading permit. The plan and report shall contain water surface profile gradient calculations for all storm drain pipes 12-inches and larger in diameter. All reports shall be wet signed and sealed by the Engineer of Record. In addition, the project specific drainage study shall provide inlet calculations showing the proper sizing of the water quality management plan storm water flows into the proposed structural storm water treatment devices. 17. Roof water is not permitted to flow over the public parkway and shall be directed to an under parkway culvert per City of Rancho Cucamonga requirements prior to issuance of a grading permit. 18. Private sewer, water, and storm drain improvements will be designed per the latest adopted California Plumbing Code. Private storm drain improvements shall be shown on the grading and drainage plan. 19. www.CityofRC.us Page 17 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval Prior to the issuance of the Certificate of Occupancy or final sign off by the Building Inspector the engineer of record shall certify the functionality of the storm water quality management plan (WQMP) storm water treatment devices and best management practices (BMP). 20. Prior to approval of the Water Quality Management Plan (WQMP), the WQMP shall include a copy of the project Conditions of Approval. 21. Prior to issuance of a grading permit the precise grading and drainage plan shall follow the format provided in the City of Rancho Cucamonga handout “Information for Grading Plans and Permit”. 22. Prior to the issuance of a Grading Permit the City of Rancho Cucamonga ’s “Memorandum of Agreement of Storm Water Quality Management Plan” shall be submitted for review and approval by the Engineering Services Department and recorded with the County Recorder’s Office. 23. Prior to issuance of a Grading Permit the applicant shall obtain a Waste Discharge Identification Number (WDID). The WDID number shall also be shown on the WQMP Site and Drainage Plan document. 24. The applicant shall provide a copy of a completed EPA Form 7520-16 (Inventory of Injection Wells) for each underground infiltration device, with the Facility ID Number assigned, to the Engineering Services Department Official prior to issuance of the Grading Permit and /or approval of the project-specific Water Quality Management Plan. A copy of EPA Form 7520-16 shall be scanned and pasted onto the permitted grading plan set, and a copy of said form shall be included in the project -specific Water Quality Management Plan. 25. The land owner shall provide an inspection report by a qualified person /company on a biennial basis for the Class V Injection Wells /underground infiltration chambers to the City of Rancho Cucamonga Environmental Program Manager. The land owner shall maintain on a regular basis all best management practices (BMP”s) as described in the Storm Water Quality Management Plan (WQMP) prepared for the subject project. All costs associated with the underground infiltration chamber are the responsibility of the land owner. 26. The land owner shall provide an inspection report on a biennial basis for the structural storm water treatment devices, commonly referred to as BMPs, to the City of Rancho Cucamonga Environmental Program Manager. The land owner shall maintain on a regular basis as described in the Storm Water Quality Management Plan prepared for the subject project. All costs associated with the underground infiltration chamber are the responsibility of the land owner. 27. The land/property owner shall follow the inspection and maintenance requirements of the approved project specific Water Quality Management Plan and shall provide a copy of the inspection reports on a biennial basis to the City of Rancho Cucamonga Environmental Program Manager. 28. A final project-specific Storm Water Quality Management Plan (WQMP) shall be approved by the Building and Safety Director, or his designee, and the City of Rancho Cucamonga ’s “Memorandum of Storm Water Quality Management Plan” shall be recorded prior to the issuance of a grading permit or any building permit. 29. www.CityofRC.us Page 18 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval The Site and Drainage Plan in the final project -specific Water Quality Management Plan shall show the locations of all roof downspout drains. if required for storm water quality purposes, the downspouts shall include filters. 30. The final project-specific water quality management plan (WQMP) shall include executed maintenance agreements along with the maintenance guidelines for all proprietary structural storm water treatment devices (BMP’s). In the event the applicant cannot get the proprietary device maintenance agreements executed prior to issuance of a grading permit, the applicant is required to submit a letter to be included within the WQMP document, and scanned and pasted onto the Site and Drainage Plan which states that prior to issuance of a certificate of occupancy with applicant shall enter into a contract for the maintenance of the proprietary storm water treatment device. If the proprietary storm water treatment device is part of a residential subdivision, prior to the sale of the residential lot, the developer shall include maintenance agreement (s) as part of the sale of the residential lot to the buyer. A copy of the maintenance agreements to be included in the sale of the property shall be included within the WQMP document. 31. Prior to issuance of a grading permit and approval of the project specific water quality management plan all private storm water catch basin inlets shall include insert filters to capture those pollutants of concern as addressed in the in the final project -specific water quality management plan (WQMP). At a minimum catch basin insert filters to capture trash and other floating debris. All catch basin insert filters shall be maintained on a regular basis as described in the “Inspection and Maintenance Responsibility for Post Construction BMP” section of the final project-specific water quality management plan. 32. Prior to issuance of a grading permit the Final Project -Specific Water Quality Management Plan shall include a completed copy of “Worksheet H: Factor of Safety and Design Infiltration Worksheet” located in Appendix D “Section VII – Infiltration Rate Evaluation Protocol and Factor of Safety Recommendations, …” of the San Bernardino County Technical Guidance Document for Water Quality Management Plans. The infiltration study shall include the Soil Engineer ’s recommendations for Appendix D, Table VII.3: Suitability Assessment Related Considerations for Infiltration Facility Safety Factors”. 33. Prior to approval of the final project -specific water quality management plan the applicant shall have a soils engineer prepare a project -specific infiltration study for the project for the purposes of storm water quality treatment. The infiltration study and recommendations shall follow the guidelines in the current adopted “San Bernardino County Technical Guidance Document for Water Quality Management Plans”. 34. Prior to the issuance of a certificate of occupancy by the Building Official, or his designee, the civil engineer of record shall file a Water Quality Management Plan (WQMP) Post Construction Storm Water Treatment Devices As-Built Certificate with the Environmental Programs Coordinator, City of Rancho Cucamonga Engineering Services Department. 35. www.CityofRC.us Page 19 of 20Printed: 4/21/2022 Project #: DRC2021-00120 DRC2022-00074, SUBTT00024 Project Name: EDR - Harvest at Terra Vista (Design Review) Location: 11220 FOOTHILL BLVD - 109012139-0000 Project Type: Design Review Master Plan, Tentative Tract Map ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Grading Section Standard Conditions of Approval As the use of drywells are proposed for the structural storm water treatment device, to meet the infiltration requirements of the current Municipal Separate Storm Sewers Systems (MS4) Permit, adequate source control and pollution prevention control BMPs shall be implemented to protect groundwater quality. The need for pre -treatment BMPs such as sedimentation or filtration shall be evaluated prior to infiltration and discussed in the final project -specific Water Quality Management Plan document. 36. Prior to issuance of a grading permit for non -residential projects the applicant shall show on the electrical plans and the permitted grading plan set the location for a future installation of an Electric Vehicle (EV) charging station/parking area per the current adopted California Green Building Standards Code, section 5.106.5.3. 37. Prior to issuance of a grading permit the applicant shall show on the site plan and the permitted grading plan set for non-residential projects the designated parking for clean air vehicles per the current adopted California Green Building Standards Code, section 5.106.5.2. 38. Prior to the issuance of a grading plan for multi -family projects, the private streets and drive aisles within multi-family developments shall include street plans as part of the Grading and Drainage Plan set. The private street plan view shall show typical street sections. The private street profile view shall show the private street/drive aisle centerline. 39. Reciprocal access easements for all parcels and maintenance agreements ensuring joint maintenance of all storm water quality structural /treatment devices and best management practices (BMP) as provided for in the project ’s Storm Water Quality Management Plan, shall be provided for by CC&R ’s or deeds and shall be recorded prior to the approval of the Water Quality Management Plan. Said CC&R ’s and/or deeds shall be included in the project site specific Storm Water Quality Management Plan (WQMP) document prior to approval of the WQMP document and recording of the Memorandum of Agreement of Storm Water Quality Management Plan. 40. www.CityofRC.us Page 20 of 20Printed: 4/21/2022 Planning Department Statement of Agreement and Acceptance of Conditions of Approval for Design Review DRC2021-00120, Tentative Tract Map 20120 (SUBTT00024), and Master Plan DRC2022- 00074 I, Brian Jacobson, as applicant for Design Review DRC2021-00120, Tentative Tract Map 20120 (SUBTT00024), and Master Plan DRC2022-00074 hereby state that I am in agreement with and accept the conditions of approval for Design Review DRC2021-00120, Tentative Tract Map 20120 (SUBTT00024), and Master Plan DRC2022-00074, for property located at the northwest corner of Foothill Boulevard and Milliken Avenue, APNs: 1077-422-51, -55, -98, -99, 1090-121-38, and - 39, Rancho Cucamonga, California, as adopted by the Planning Commission of the City of Rancho Cucamonga on April 27, 2022 and as listed below and attached. Applicant Signature____________________________ Date ______________________________ Conditions of Approval 1.The applicant shall sign the Statement of Agreement and Acceptance of Conditions of Approval provided by the Planning Department. The signed Statement of Agreement and Acceptance of Conditions of Approval shall be returned to the Planning Department prior to the submittal of grading/construction plans for plan check, request for a business license, and/or commencement of the approved activity. 2.All conditions of approval attached to Resolution of Approval No. 22-10 for Master Plan DRC2022-00074, 22-11 for Design Review DRC2021-00120, and 22-12 for Tentative Tract Map 20120 (SUBTT00024) Exhibit R SUBJECT: LOCATED AT THE SOUTHWEST OF DAYTON DRIVE AND BUFFALO AVENUE – CONDITIONAL USE PERMIT DRC2022-00053 - PARAMOUNT LOGISTICS - A request to operate an 85,026 square foot Wholesale, Storage, and Distribution (Medium) land use in the Neo Industrial (NI) District at 11601 Dayton Drive; APN: 0229-262-09. RECOMMENDATION: Staff recommends the Planning Commission take the following action: • Approve Conditional Use Permit DRC2022-00053 through the adoption of the attached Resolution of Approval with Conditions. EXECUTIVE SUMMARY: • A request to operate an 85,026 square foot Wholesale, Storage, and Distribution (Medium) land use in the Neo Industrial (NI) District. PROJECT AND SITE DESCRIPTION: The 16-acre project site is developed with an existing 257,095 square foot rail-served industrial building with 51 dock high doors, 51 trailer parking spaces, and 307 passenger vehicle parking spaces. The project site is accessed by two vehicle entrances on Buffalo Avenue and one on Dayton Drive. The table below provides the existing Land Use, General Plan, and Zoning Designations for the project site and surrounding properties: A. Project Overview: The applicant has requested to operate a ”Wholesale, Storage, and Distribution (Medium)” land use in the Neo-Industrial (NI) District. The existing 257,095 DATE: April 27, 2022 TO: Chairman and Members of the Planning Commission FROM: Matthew R. Burris, AICP, LEED AP, Deputy City Manager – Community Development, Interim Planning Director INITIATED BY: Tabe van der Zwaag, Associate Planner Land Use General Plan Zoning Site Industrial Building Neo-Industrial Employment District Neo-Industrial (NI) District North Industrial Building Neo-Industrial Employment District Neo-Industrial (NI) District South Industrial Building Neo-Industrial Employment District Neo-Industrial (NI) District East Industrial Building Neo-Industrial Employment District Neo-Industrial (NI) District West Industrial Building Neo-Industrial Employment District Neo-Industrial (NI) District Page 2 square foot building was originally occupied entirely by Mission Foods. As they no longer need this amount of floor area to conduct their operations, the interior of the building will be divided into two tenant spaces with the applicant (Paramount Logistics) occupying 85,026 square feet and Mission Foods) occupying the remaining 172,069 square feet. The project site provides the minimum required trailer parking (51) spaces and 180 excess standard parking spaces as outlined in the following table. Parking Ratio Required Parking Provided Parking Wholesale – First 20,000 1:1,000 SF 20 Spaces Wholesale – Next 20,000 1:2,000 SF 10 Spaces Wholesale - Remaining SF (205,610 SF) 1:4,000 51 Spaces Office Areas (11,485 SF) 1:250 SF 46 Spaces Trailer Parking (51 Dock Doors) 1 Per Dock Door 51 Spaces Total Parking Spaces 127 Vehicle Spaces + 51 Trailer Spaces 307 Vehicle Spaces + 51 Trailer Spaces B. Conditional Use Permit: Development Code Table 17.30.030-1 requires that the use of an existing building for “Wholesale, Storage, and Distribution (Medium)” where the building is over 50,000 square feet or the tenant will occupy over 50,000 square feet within a building is subject to Planning Commission approval of a Conditional Use Permit. Wholesale, Storage and Distribution (Medium) is defined in Section 17.32.020 (Allowed use descriptions) of the Development Code as follows: Activities typically include, but are not limited to, wholesale, storage, and warehousing services; moving and storage services; storage and wholesaling to retailers from the premises of finished goods and food products; and distribution facilities for large-scale retail firms. Activities under this classification shall be conducted in enclosed buildings and occupy greater than 50,000 square feet of building space. Included are multi-tenant or speculative buildings with over 50,000 square feet of Wholesale space. The applicant proposes operating an 85,026 square foot wholesale, storage, and distribution facility. The business operations consist of transporting cargo containers from the Port of Long Beach and/or the Port of Los Angeles to the facility (or similar), transferring the various packages, boxes, etc. from the containers to separate outbound truck trailers (in an operating environment referred to as a “cross-dock” where there is no long-term storage), and shipping them to their next destination for further processing. The majority of each cargo container’s shipment leaves the facility within a week of when it arrives at the facility, i.e. turnover is within about one week. Approximately 20 percent of the product leaving the facility will be shipped directly to the consumer via UPS, FedEx, etc. The proposed facility will operate 24 hours per day in three shifts (8:00 a.m. to 5:00 p.m., 5:00 p.m. to 1:00 a.m., and 1:00 a.m. to 8:00 a.m.) with a maximum of 25 personnel onsite during the largest shift (8:00 a.m. to 5:00 p.m.). There will be minimal change from the Page 3 current operations of the entire facility by Mission Foods which currently operates on a 24- hour schedule. The applicant states that the number of trucks and trails on site will never surpass the number of available dock doors and trailer parking spaces and that the number of trucks and trailers entering should be similar to the current operation with Mission Foods occupying the entire facility. Based on the similarity in business operations, staff determined that a Parking Management Plan was not required at this time. If truck traffic and parking become an issue in the future, a Parking Management Plan may be required to remedy any negative impacts on the surrounding land uses and public infrastructure. Mission Foods will be separated from the applicant’s tenant space by an interior demising wall with separate dock-high doors (32 total). They will continue to use their tenant space to wholesale and store raw food ingredients and finished food products to serve their facilities. Representatives from Mission Foods have informed staff that they will have approximately 25-30 trailers onsite to support their operation. Staff has included a Condition of Approval which limits onsite trucks and trailers to the available number of dock door and trailer parking spaces. The applicant has stated that if in the future the existing truck/trailer parking exceeds the available onsite number of parking spaces they will submit the necessary entitlements to reconfigure the existing passenger vehicle parking lot for use as truck/trailer parking. The project site includes 3 vehicle entrances which can be used for accessing either tenant space with minimal interference between the two tenants. C. Environmental Assessment: Prior to any action being taken for this request, Planning Department staff has determined that the project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA). The project qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 which covers the operation, permitting, leasing, or minor alteration of existing structures. The project involves the operation of an 85,026 square foot Wholesale, storage, and distribution land use within an existing industrial tenant space that previously housed a similar use of the same type and intensity. No exterior physical alterations to the building are being proposed with the application. Staff finds that there is no substantial evidence that approval of the project will have a significant effect on the environment. The Planning Director has reviewed the Planning Department’s determination of exemption, and based on his own independent judgment, concurs with staff’s determination of exemption. FISCAL IMPACT: The proposed business will employ approximately 33 persons on three shifts potentially increasing demand for local services. COUNCIL GOAL(S) ADDRESSED: The project fulfills City Council Core Value #7 (Continuous Improvement). By subdividing an underutilized building, the new business may increase the number of employment opportunities in the City. Page 4 CORRESPONDENCE: This item was advertised as a public hearing with a regular page legal advertisement in the Inland Valley Daily Bulletin newspaper, the property was posted on April 12, 2022, and notices were mailed to all property owners (10 addresses) within a 660-foot radius of the project site on April 12, 2022. To date, no comments/correspondence has been received in response to these notifications. EXHIBITS: Exhibit A - Aerial Photo Showing Project Location Exhibit B - Letter of Business Operation Exhibit C - Site Utilization Map Exhibit D - Site Plan Exhibit E - Floor Plan Exhibit F - Tenant List with Hours of Operation Exhibit G - Draft Resolution of Approval 22-13 for Conditional Use Permit DRC2022-00053 Exhibit H - Draft Conditions of Approval Exhibit I - Statement of Agreement Exhibit A 4826 4th St Irwindale, CA 91706 Tel: (626) 575-7988 Fax: (626) 575-7966 Email: info@paramountloginc.com Business operation 1, Services offered •Drayage: Pick up ocean containers from the port of Long Beach to our warehouse •Transloading/Crossdocking: Fast in & out normally within a week. Usually pallet/cartons in & pallet out within a week. •Distribution: a) Customer’s choice on receiving (ocean container, truckload, less than truckload, loose cargo). b) Inventory management, 24 x 7 real time inventory monitoring c) Outbound: Full Pallet, case pick, E-commerce (parcel shipping) Commodity: general merchandise, consumer goods 2, Hour of operation: •First shift: 8 am – 5 pm full service •Second shift: 5 pm- 1 am, accepting inbound trailer drop off only, protentional offering full service •Third shift: 1 am -8 am in plan for accepting inbound trailer drop off only 3, Number of employees on the largest shift (First Shift) •10 truck drivers •10 warehouse employees •5 office clerical employees 4, The reasons for requesting CUP •Storage and distribution inside of the warehouse •Truck & Trailer parking Exhibit B 600' (TYP.)SUBJECT SITE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI) OFFICE/ WAREHOUSE (GI)OFFICE/ WAREHOUSE (GI) WAREHOUSE (GI) WAREHOUSE (GI) Exhibit C Exhibit D Exhibit E List of all tenants within the center or complex by name, address, type of use, square footage, and hours of operation: Gruma Corporation dba Mission Foods, 11671 Dayton Drive, distribution of bagged flour / tortillas / chips and other food-related items, 172,560 square feet, hours of operation are 24 hours M-F, closed Sat at 830pm and re-open Sunday at 10am. RESOLUTION NO. 22-13 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, APPROVING CONDITIONAL USE PERMIT DRC2022-00053, A REQUEST TO OPERATE AN 85,026 SQUARE FOOT WHOLESALE, STORAGE, AND DISTRIBUTION (MEDIUM) LAND USE IN THE NEO INDUSTRIAL (NI) DISTRICT AT 11601 DAYTON DRIVE; AND MAKING FINDINGS IN SUPPORT THEREOF – APN: 0229-262-09. A.Recitals. 1.PARAMOUNT LOGISTICS filed an application for the approval of Conditional Use Permit DRC2022-00053, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Conditional Use Permit request is referred to as "the application." 2.On the 27th day of April 2022, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on the application and concluded said hearing on that date. 3.All legal prerequisites prior to the adoption of this Resolution have occurred. B.Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1.This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2.Based upon the substantial evidence presented to this Commission during the above-referenced public hearings of April 27, 2022, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a. The project site is located at the southwest corner of Dayton Drive and Buffalo Avenue; and b.The 16-acre project site is developed with an existing 257,095 square foot rail-served industrial building with 51 dock high doors, 51 trailer parking spaces and 307 passenger vehicle parking spaces; and c.The existing Land Use, General Plan and Zoning Designations for the project site and adjacent properties are as follows: Land Use General Plan Zoning Site Industrial Building Neo Industrial Employment District Neo Industrial (NI) District North Industrial Building Neo Industrial Employment District Neo Industrial (NI) District South Industrial Building Neo Industrial Employment District Neo Industrial (NI) District East Industrial Building Neo Industrial Employment District Neo Industrial (NI) District West Industrial Building Neo Industrial Employment District Neo Industrial (NI) District d.The applicant has requested to operate a Wholesale, Storage, and Distribution (Medium) land use in the Neo Industrial (NI) District. The existing 257,095 square foot building will be divided into two tenant spaces with the applicant (Paramount Logistics) occupying 85,026 square feet and the existing tenant (Mission Foods) occupying the remaining 172,069 square feet. The project site Exhibit G PLANNING COMMISSION RESOLUTION NO. 22-13 DRC2022-00053 – PARAMOUNT LOGISTICS April 27, 2022 Page 2 provides the minimum required trailer parking (51) spaces and 307 passenger vehicle parking spaces, which is 180 spaces in excess of the required number of parking spaces; and e. Development Code Table 17.30.030-1 requires that Wholesale, Storage, and Distribution (Medium) land uses over 50,000 square feet in area require Planning Commission approval of a Conditional Use Permit; and f. The applicant proposes operating an 85,026 square foot wholesale, storage, and distribution facility. The business operations consist of transporting cargo containers from the Port of Long Beach and/or the Port of Los Angeles to the facility (or similar), transferring the various packages, boxes, etc. from the containers to separate outbound truck trailers (in an operating environment referred to as a “cross-dock” where there is no long-term storage), and shipping them to their next destination for further processing. The majority of each cargo container’s shipment leaves the facility within a week of when it arrives at the facility, i.e. turnover is within about one week. Approximately 20 percent of the product leaving the facility will be shipped directly to the consumer via UPS, FedEx, etc.; and g. The proposed facility will operate 24 hours per day in three shifts (8:00 a.m. to 5:00 p.m., 5:00 p.m. to 1:00 a.m., and 1:00 a.m. to 8:00 a.m.) with a maximum of 25 personnel onsite during the largest shift (8:00 a.m. to 5:00 p.m.). There will be minimal change from the current operations of the entire facility by Mission Foods which currently operates on a 24-hour schedule; and h. The applicant states that the number of trucks and trailers on site will never surpass the number of available dock doors and trailer parking spaces and that the number of trucks and trailers entering should be similar to the current operation with Mission Foods occupying the entire facility. Based on the similarity in business operations, staff determined that a Parking Management Plan was not required at this time. If truck traffic and parking become an issue in the future, a Parking Management Plan may be required to remedy any negative impacts on the surrounding land uses and public infrastructure. 3. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing and upon the specific findings of facts set forth in Paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: a. The proposed project is consistent with the General Plan. The General Plan land use designation for the project site is Neo Industrial Employment District which permits a wide variety of industrial land uses including wholesale, storage, and distribution; and b. The proposed use is consistent with the purposes of the development code and the purposes of the applicable zoning district as well as any applicable specific plans or city regulations/standards. Wholesale, storage, and distribution land uses are permitted within the Neo Industrial (NI) District subject to Planning Commission approval of a Conditional Use Permit; and c. The site is physically suitable for the type, density, and intensity of the use being proposed, including access, utilities, and the absence of physical constraints that would make conduct of the use undesirable. The project site is developed with an existing 257,075 square foot industrial building that is surrounded by industrial development and is served by existing utilities and includes vehicle access from two adjacent public streets and a rail spur line; and PLANNING COMMISSION RESOLUTION NO. 22-13 DRC2022-00053 – PARAMOUNT LOGISTICS April 27, 2022 Page 3 d. The design, location, size, and operating characteristics of the proposed use would be compatible with the existing and other permitted uses in the vicinity including transportation and service facilities. The proposed use is located in an existing industrial building and is surrounded by similar wholesale, storage, and distribution land uses with similar operating characteristics; and e. Granting the permit would not constitute a nuisance or be detrimental to the public interest, health, safety, convenience, or welfare, or materially injurious to persons, property, or improvements in the vicinity and zoning district in which the property is located. The applicant is not proposing any new activities which were not already occurring with the existing tenant beyond subdividing the existing tenant space into two tenant spaces. The proposed business will operate within the confines of the existing number of dock doors and trailer parking spaces that currently exist. All activities will take place on the project site, and the adjacent roadways were designed to accommodate a wholesale use with the level of proposed vehicle trips. Thus, the project is not expected to: 1) create any property damage or nuisance from noise, smoke, odor, dust, vibration, or illumination caused by the use; create hazards to persons or property from possible explosions, contamination, fire or flood caused by the use; or 3) significantly increase the volume of traffic or negatively alter the pattern of traffic; and f. The proposed use will not pose an undue burden on city services, including police, fire, streets, and other public utilities, such that the city is unable to maintain its current level of service due to the use. The proposed is not expected to pose a burden on city services beyond that which is typical for a similarly sized wholesale, storage, and distribution land use. g. The proposed project has been reviewed in compliance with the California Environmental Quality Act (CEQA). The project qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 which covers the operation, permitting, and leasing, of existing structures. No changes are proposed to the project site. 4. Planning Department staff determined that the project is categorically exempt from the requirements of the California Environmental Quality Act (CEQA). The project qualifies as a Class 1 exemption under State CEQA Guidelines Section 15301 which covers the operation, permitting, leasing, or minor alteration of existing structures. The project involves the operation of an 85,026 square foot wholesale, storage, and distribution land use. No exterior physical alterations to the building are being proposed with the application. Staff finds that there is no substantial evidence that approval of the project will have a significant effect on the environment. The Planning Director has reviewed the Planning Department’s determination of exemption, and based on his own independent judgment, concurs with staff’s determination of exemption. 5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth in the Standard Conditions, attached hereto and incorporated herein by this reference. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 27TH DAY OF APRIL 2022. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA PLANNING COMMISSION RESOLUTION NO. 22-13 DRC2022-00053 – PARAMOUNT LOGISTICS April 27, 2022 Page 4 BY: Bryan Dopp, Chairman ATTEST: Matthew R. Burris, Secretary, AICP, LEED AP I, Matthew R. Burris, Secretary, AICP, LEED AP, of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 27th day of April 2022, by the following vote-to-wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS: Conditions of Approval Community Development Department Project #: DRC2022-00053 Project Name: Paramount Logistics - CUP Location: 11601 DAYTON DR - 022926209-0000 Project Type: Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Please be advised of the following Special Conditions The number of onsite trailers/trucks shall not exceed the available onsite dock doors/trailer parking spaces. 1. Trucks/trailers shall not queue on the public streets while waiting for access to the facility.2. If truck traffic or truck/trailer parking become an issue in the future, a Parking Management Plan may be required to remedy any negative impacts on the surrounding land uses and public infrastructure. 3. Standard Conditions of Approval The applicant shall sign the Statement of Agreement and Acceptance of Conditions of Approval provided by the Planning Department. The signed Statement of Agreement and Acceptance of Conditions of Approval shall be returned to the Planning Department prior to the submittal of grading/construction plans for plan check, request for a business license, and/or commencement of the approved activity. 4. The applicant shall agree to defend at his sole expense any action brought against the City, its agents, officers, or employees, because of the issuance of such approval, or in the alternative, to relinquish such approval. The applicant shall reimburse the City, its agents, officers, or employees, for any Court costs and attorney's fees which the City, its agents, officers, or employees may be required by a court to pay as a result of such action. The City may, at its sole discretion, participate in the defense of any such action but such participation shall not relieve applicant of his obligations under this condition. In the event such a legal action is filed, the City shall estimate its expenses for litigation. The applicant shall deposit such amount with the City or enter into an agreement with the City to pay such expenses as they become due. 5. Copies of the signed Planning Commission Resolution of Approval or Approval Letter, Conditions of Approval, and all environmental mitigations shall be included on the plans (full size). The sheet(s) are for information only to all parties involved in the construction/grading activities and are not required to be wet sealed/stamped by a licensed Engineer/Architect. 6. The applicant shall be required to pay California Department of Fish and Wildlife Notice of Exemption fee in the amount of $50.00. All checks are to be made payable to the Clerk of the Board Supervisors and submitted to the Planning Commission Secretary prior to public hearing or within 5 days of the date of project approval. 7. www.CityofRC.us Printed: 4/20/2022 Exhibit H Project #: DRC2022-00053 Project Name: Paramount Logistics - CUP Location: 11601 DAYTON DR - 022926209-0000 Project Type: Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Planning Department Standard Conditions of Approval Any modification or intensification of the approved use, including revisions in the operations of the business including changes to the operating days /hours; change in the location on -site or within the building of the use /activity that is approved by this Conditional Use Permit; improvements including new building construction; and /or other modifications /intensification beyond what is specifically approved by this Conditional Use Permit, shall require the review and approval by the Planning Director prior to submittal of documents for plan check /occupancy, construction, commencement of the activity, and /or issuance of a business license. The Planning Director may determine that modifications or intensifications of use require the submittal of an application to modify this Conditional Use Permit for review by the City. 8. All building numbers and individual units shall be identified in a clear and concise manner, including proper illumination and in conformance with Building and Safety Services Department standards, the Municipal Code and the Rancho Cucamonga Fire Department (RCFD) Standards. 9. Fire Prevention / New Construction Unit Standard Conditions of Approval If egress lighting needs to be provided, or if existing egress lighting needs to be modified, plans for the egress lighting are required to be submitted separately and issued a separate permit. Submit all plans to the Building & Safety Department for routing to the Fire District. 1. If storage operations will include high piled combustible storage, a high piled combustible storage analysis and all associated plans are required to be submitted separately and issued separate permits . Please see Fire District Standard 32-1. Submit all plans to the Building & Safety Department for routing to the Fire District. 2. If new storage racks will be installed or existing storage racks relocated, plans for the racks are required to be submitted separately and issued a separate permit. Submit all plans to the Building & Safety Department for routing to the Fire District. 3. If modifications to the automatic fire sprinkler system are needed, plans for the modifications are required to be submitted separately and issued a separate permit. Submit all plans to the Building & Safety Department for routing to the Fire District. 4. If not already provided with the correct signage, exterior doors and doors providing access to fire protection and life safety systems and equipment are required to have identification signage in accordance with Fire District Standard 5-5. The Standard has been uploaded to the Documents section. 5. If the existing emergency egress needs to be modified, provide an exit analysis complete with exit width capacity calculations, the required number and arrangement of exits, path of egress travel distances, and a main exit designation and capacity calculation where applicable. 6. If the storage operation will include high -piled combustible storage, such storage and associated protection systems are required to be in accordance with Chapter 32 of the Fire Code and Fire District Standard 32-1. Please read and understand this Standard in its entirety to avoid delays in scheduling inspections and obtaining approvals. The Standard has been uploaded to the Documents section. 7. www.CityofRC.us Page 2 of 3Printed: 4/20/2022 Project #: DRC2022-00053 Project Name: Paramount Logistics - CUP Location: 11601 DAYTON DR - 022926209-0000 Project Type: Conditional Use Permit ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT: Fire Prevention / New Construction Unit Standard Conditions of Approval Storage of Class I-IV commodities above 12 feet or High Hazard commodities above 6 feet is not allowed without an approved high -piled combustible storage permit issued by the Fire District. Please see Fire District Standard 32-1. A copy of the Standard has been uploaded to the Documents section. 8. If not already provided specifically for the lease space, a Knox Box key box is required in accordance with Fire District Standard 5-9. Additional boxes may be required depending on the size of the building, the location of fire protection and life safety system controls, and the operational needs of the Fire District. The Standard has been uploaded to the Documents section. If an installed Knox Box is available to this project or business, keys for the building /suite/unit are required to be provided to the Fire Inspector at the final inspection. 9. One or more of the operations proposed for this building /business may require a Fire Code Operating Permit to be issued in accordance with the Fire Code and Fire District Standard 1-1. The Standard has been uploaded to the Documents section. 10. A Fire Final Inspection is required prior to final inspection and approval by the Building Department.11. Building and Safety Services Department Please be advised of the following Special Conditions When the Entitlement Review is approved submit complete construction drawings for all proposed tenant improvements including energy calculations to Building and Safety for plan review in accordance with the current edition of the CA Building and Fire Codes including all local ordinances and standards which are effective at the time of Plan Check Submittal. Modifications to the existing automatic fire sprinklers are required to be a separate submittal /permit from the tenant improvement submittal/permit. Disabled access for the site and building must be in accordance to the State of CA and ADA regulations. If there is any plumbing work on your plans please contact CVWD ASAP (Local water district ), their turnaround timeline is 4-6 weeks to grant a plumbing first release. A “Plumbing First Release” is required before B&S issues a demolition or TI permit when there is plumbing involved. 1. www.CityofRC.us Page 3 of 3Printed: 4/20/2022 Planning Department Statement of Agreement and Acceptance of Conditions of Approval for Conditional Use Permit DRC2022-00053 I, _____________________, as applicant for Conditional Use Permit DRC2022-00053, hereby state that I am in agreement with and accept the Conditions of Approval for above-mentioned applications, for property located at 11601 Dayton Drive.; APN: 0229-262-09, Rancho Cucamonga, California. Applicant Signature____________________________ Date ______________________________ Conditions of Approval 1.The applicant shall sign the Statement of Agreement and Acceptance of Conditions of Approval provided by the Planning Department. The signed Statement of Agreement and Acceptance of Conditions of Approval shall be returned to the Planning Department prior to the submittal of grading/construction plans for plan check, request for a business license, and/or commencement of the approved activity. 2.All other conditions of approval related to Resolution of Approval 22-13 for Conditional Use Permit DRC2022-00053. Exhibit I Page 1 DATE: April 27, 2022 TO: Chairman and Members of the Planning Commission FROM: Matthew R. Burris, AICP, LEED AP, Deputy City Manager – Community Development, Interim Planning Director INITIATED BY: Jennifer Nakamura, Deputy Director of Planning SUBJECT: Consideration of a Recommendation to the City Council to Adopt a Comprehensive revision to Title 17 (Development Code) of the Rancho Cucamonga Municipal Code, Adopt a Revised Zoning Map and Repeal or Amend Several Specific Plans, Planned Communities and Master Plans to Implement the Goals and Policies of the General Plan. This Item Will be Forwarded to City Council for Final Action. RECOMMENDATION: Staff recommends that the Planning Commission adopt a resolution recommending the City Council adopt an addendum to the General Plan Environmental Impact Report (PEIR) SCH# 2021050261 and adopt a series of amendments to the Rancho Cucamonga Municipal Code that will do the following: Adopt a comprehensive revision to Title 17 of the Rancho Cucamonga Municipal Code to implement the goals and policies of the recently adopted General Plan, including, but not limited to: • Develop implementing zones for all General Plan land use designations; • Add a new Article implementing form based zoning for specific mixed use zones; • Incorporate key standards from Specific Plans and Planned Communities into the Development Code; • Revise permit procedures to streamline development review; • Comply with State Law; and Adopt a revised Zoning Map: • Establishes new zoning districts that implement the General Plan land use designations; • Removes Specific Plans, Master Plans, Planned Communities and Overlay Zones; and Repeal the following Specific Plans, Master Plans, Planned Communities and Overlay Zones: • Etiwanda Highlands Planned Unit Development; • Etiwanda North Specific Plan; • Etiwanda Specific Plan; • Terra Vista Community Plan; • Town Square Master Plan; • Victoria Community Plan; • Foothill Boulevard Overlay; • Haven Avenue Overlay; • Mixed Use Overlay; • Industrial Commercial Overlay; and Amend the Empire Lakes Specific Plan to change the boundary and rename to The Resort Specific Plan; Page 2 BACKGROUND: On December 15, 2021, the City Council unanimously adopted the updated General Plan for the City of Rancho Cucamonga. The General Plan is the City’s blueprint, or constitution, for future development. It documents the City’s long-range vision and established clear goals, objectives and actions to guide the community through the next 10 to 20 years of change. The City Council initiated this update process, referred to as PlanRC, to be compliant with changes in state law and to build on our success as a world class community to create a balanced, vibrant and innovative city. This comprehensive General Plan Update addresses issues and challenges facing the City, including diversifying employment opportunities, expanding housing and mobility choice and preserving the character, history, and quality of life that make Rancho Cucamonga a special place to live. The updated General Plan will advance the City’s vision for a sustainable, resilient, equitable and healthy community. While the General Plan is the policy document that provides an overall vision, policy direction, and implementation strategy to support future development in Rancho Cucamonga, the Development Code implements General Plan policies through detailed development regulations, such as specific use types and building standards. Although the purpose and intent of zoning is different from the General Plan, state law requires that zoning be consistent with maps and policies in the General Plan. Uses and densities/intensities are permitted if they are consistent with both the General Plan land use designation and the zoning of the property. When a zoning ordinance becomes inconsistent due to a general plan amendment, the City must enact a consistent zoning ordinance within a reasonable time. The adoption of the General Plan has spurred development interest and is resulting in an increase in applications for large-scale projects. Currently, there are over 1,700 residential units and approximately 64,000 square feet of commercial development in the pipeline along the major corridors in the southern portion of the city. The current Development Code is not consistent with the intent of the character-based General Plan Land Use Designations and does not contain the necessary standards to implement the General Plan vision for walkable, mixed-use places. City staff have been working with a consultant team on amendments to the Development Code and Zoning Map to implement the Land Use Designations in the updated General Plan, including the addition of form-based code components for the new mixed-use place types established in the General Plan. ANALYSIS: The goals of the Development Code update are to codify the community’s vision as established in the General Plan update process, increase certainty in the development review process, and facilitate implementation of key General Plan concepts related to land use and urban design. A primary objective is to integrate form-based regulations in appropriate areas, such as along Foothill Boulevard, to promote pedestrian activity and transition these areas from auto-oriented to more walkable and urban configurations. Fundamental elements of the Development Code update are: • A hybrid Development Code that integrates form-based and conventional zones. • New form-based zoning regulations for walkable mixed-use areas along Foothill Boulevard and other key corridors. • Incorporation of appropriate standards from older Specific Plans and Planned Communities into the new zoning regulations to allow for repeal of outdated plans. • New objective design standards for multi-family residential and mixed-use development projects. • Revisions to conventional zones as needed to implement the land use vision of the General Plan. • Revised general development standards to address General Plan policy or existing deficiencies with respect to landscaping, open space, and noise, among others as needed. • Improved administration and permit procedures to streamline development review for projects consistent with the General Plan and ensure adequate tools for enforcement of the Code. • Compliance with State and Federal law. • Consistency with the updated General Plan. Page 3 General Plan Consistency The existing Development Code was reviewed for consistency with the goals and policies of the adopted General Plan. Where a gap or inconsistency was identified, the Development Code was amended to provide adequate provisions to facilitate development in alignment with the policy direction of the General Plan. In addition, the intent and purpose of each General Plan land use designation was assessed to determine whether the designation could be implemented with an existing zoning district or if a new zone was needed. Recommendations to implement the General Plan and the creation of new form-based zones to implement the new mixed-use land use designations are described below. Implementation of the General Plan Vision To successfully achieve the City’s vision and uphold the core values identified by the community during the PlanRC process, the General Plan is designed around strengthening Rancho Cucamonga’s sense of identity and character by creating places where people want to be and improving their ability to move around. The overarching strategy is one of human-scaled design, with buildings and outdoor spaces oriented towards people connected by safe and comfortable streets, pathways, and trails that provide equitable access for all. The General Plan organizes the city into districts, centers, corridors, and neighborhoods, with an overall vision for greater walkability centered around nodes of activity. Vision Diagram Page 4 The Land Use and Community Character Chapter of the General Plan describes and defines the distinct types of places—or “place types”—that the City aims to create to achieve the vision. The General Plan unifies the inseparable topics of land use and community character and design into a single chapter to ensure that the uses, experiences, and activities that current and future community members enjoy in our city cannot be divorced from our vision for the unique look, feel, character, ambiance and quality of life that we enjoy in Rancho Cucamonga. Given the City’s broad place-making goals and the community’s interest in shaping the form and character of the city, the General Plan uses “place type” designations that go beyond conventional land use designations to better define the existing and intended character, form, and function of each part of the city. Each place type is organized into designations that provide direction on the intended range of uses, appropriate levels of development density and intensity, and intended physical design character. The Land Plan is illustrated below and is also available on the City’s website: https://bit.ly/gplandplan. Land Plan Page 5 Form-Based Code The Form-Based Code (FBC) implements the General Plan’s vision, place type designations, and policy direction for key areas of the city, including the major corridors, focus areas and activity nodes. The FBC, which is Article VIII of Title 17 (Development Code), establishes place-based standards for certain areas that are intended to promote pedestrian activity, encourage a diversity of uses, accommodate new housing typologies, and facilitate the transition of auto-oriented areas to more walkable and urban places. The FBC represents an alternative to a conventional zoning code’s approach to the way the built environment is regulated. The definition of a Form-Based Code is as follows: “Form-Based Codes foster predictable built results and a high-quality public realm by using physical form (rather than separation of uses) as the organizing principle for the code. These codes are adopted into city or county law as regulations, not mere guidelines. Form-Based Codes are an alternative to conventional zoning.” (Source: Form-Based Codes Institute) Unlike conventional, use-based codes, FBCs utilize the intended form and character of a neighborhood rather than use as the organizing framework of the code. FBCs address the relationship between building facades and the public realm (i.e., sidewalk, street), the form and mass of buildings in relation to one another, and the scale and types of buildings and blocks. Regulations and standards in the FBC are presented graphically in diagrams and photographs as well as supplemental text. These standards are keyed to the zoning map, assigning an appropriate form and scale through the application of form-based zones to specific lots for key areas of the city where mixed use urban form is desired. The remainder of the city uses conventional zoning as regulated by Article III of the Development Code. While the FBC focuses on an intended physical form, it also regulates use by allowing a mix of appropriate land uses chosen to ensure compatibility among different contexts and the intended physical form of the area. The FBC is intended to transform our commercial corridors and centers into vibrant, mixed-use areas where residents can live, work, and play within close walking distance. Article VIII is organized around the following regulating topic areas: • Zone and Building Standards: establishes purpose and intent of building type standards, standards that are applicable to all form-based zones and building types, descriptions of each building type, and objective development standards associated with each building type. • Building Entrances and Facades: establishes purpose and intent of building entrance and facade type standards, descriptions of each building entrance and facade type, and objective development standards associated with each type. • Public Open Space: establishes purpose and intent of public open space standards, descriptions of each public open space type, and objective development standards associated with each type. • Land Use Standards: establishes the land uses allowed in each form-based zone and any necessary specific use standards. Page 6 • Large Site Development: provides requirements for large site development including applicability, intent and design review requirements; and establishes block size and connectivity standards. Objective Design Standards Another key component of the updated Development Code is new objective design standards for multi-family residential and mixed-use development projects to respond to changes in state law and facilitate housing production. State law defines objective standards as those that “involve no personal or subjective judgement by a public official and are uniformly verifiable by reference to an external and uniform benchmark or criterion available and knowable by both the development applicant and public official prior to submittal.” They are measurable and verifiable (i.e., no “gray area” for interpretation) to make the design review process more streamlined, predictable, and easier to interpret. The purpose of objective design standards is for applicants to know beforehand what requirements apply to a proposed development and for the applicant to be able to design a project that meets those requirements before submittal. Objective design standards are written as requirements, rather than guidelines, and will provide applicants and developers with a clear understanding of the City’s expectations for mixed-use and multi-family residential project design to help streamline the review process. Objective design standards that are intended to complement all base zoning districts are contained in Article VII, while objective standards specifically aimed at mixed use and multi-family development in the form-based zones are integrated into Article VIII. Repeal of Older Specific Plans, Master Plans and Planned Communities Part of the Development Code update includes the incorporation of appropriate standards from older specific plans, master plans and planned communities into the new zoning regulations to allow for the repeal of outdated plans. In many instances these original plans are fully built out, and in others revisions to the code will supersede the need for the specialized zoning or standards allowed by the specific plan, master plan or planned community. Because many of the City’s specific plans, master plans and planned communities were prepared over 30 years ago, they are difficult to interpret and amendments are often required to accommodate different types of development not contemplated in the 1980s and 1990s. The following is the list of specific plans, master plans and planned communities to be repealed with adoption of the updated Development Code: • Etiwanda Highlands Planned Unit Development (EH) 1988 - Repeal • Etiwanda North Specific Plan (ENSP) 1992- Repeal • Etiwanda Specific Plan (ESP) 1985 - Repeal • Terra Vista Community Plan (TVCP) 1983 - Repeal • Town Square Master Plan (TS) 2002 - Repeal • Victoria Arbors Master Plan (VA) 2002 - Repeal • Victoria Community Plan (VCP) 1981 - Repeal • Empire Lakes Specific Plan (ELSP) (Also referred to as IASP Sub-Area 18 Specific Plan) 1994 – Amend to change boundary and renamed to The Resort Specific Plan In order to maintain compatibility of new infill development and to avoid the creation of non-conforming uses and structures, applicable standards from these plans have been incorporated into the new form-based zones and/or integrating into the Development Code through the use of subzones, which are subsets of the primary conventional zone. Subzones align with the primary zone development standards and use requirements except where otherwise noted to maintain the necessary standards of the repealed plan. Because of inconsistencies between the Development Code, the regulations of the repealed plans, and what is built, the Development Code includes provisions for staff to allow flexibility based on existing development that may become non- conforming. Page 7 Legal Consistency Legal requirements relative to this code update were analyzed and where the Development Code was determined to be out of compliance, amendments to the code were made. The following topic areas were amended to bring the City’s Development Code into compliance with state and federal law: • Special needs housing, including community care facilities, family day care homes, emergency shelters, farmworker housing • Accessory dwelling units • Manufactured homes • Telecommunications facilities, including review of wireless telecommunications facilities and acceleration of broadband deployment • Density bonuses, incentives and concessions • Fine-tuning of permit review requirements General Code Issues In addition, and as part of the process, the consultant for the Development Code update led a series staff interviews with representatives from the Planning Department, Engineering Department, Building and Safety Department, Animal Services and Community Improvement Division to identify opportunities to clarify code content, address existing deficiencies, or improve usability. The following topics were amended to address staff identified issues: • Amendments to review applicability and process language for a variety of application types for clarity. • Changes to home occupation permit regulations to prohibit home based businesses performing ammunition recycling. • Removal of the planned community process which is not used anymore and changes to specific plan size threshold. • Modifications to the allowed use table and descriptions for certain allowed uses. • Updates to development standards for residential zones to allow for more residential types to expand opportunities for a range of residential development. • Removal of several Overlay Zoning Districts that are no longer applicable with the amendments to the code and the inclusion of the form-based code. The Overlays to be removed include: Industrial/Commercial, Foothill Boulevard, Mixed Use, and Haven Avenue Overlay Zoning Districts. • Changes to requirements and exceptions for certain accessory structures. • Reductions of guest parking standards for residential uses. • Addition of parking management standards to address spillover parking from large projects into adjacent residential neighborhoods. • Updates animal keeping standards to make them easier to apply and enforce and to allow for a wider variety of pets on smaller lot sizes. • Comprehensive update to general design provisions and design provisions by development type. • Revisions to the Zoning Map for consistency with the General Plan and Development Code and to implement the new Form-Based Zones. COMMUNITY ENGAGEMENT: PlanRC Engagement Process A primary purpose of the Development Code update is for consistency with, and implementation of, the recently adopted General Plan, which reflects the vision and core values of the community. The City started PlanRC, the name for the General Plan Update process, in January 2020. Throughout the nearly two-year process leading up to General Plan adoption, the City conducted a robust engagement effort with the public. Community input was solicited and reflected throughout each phase of the planning process. PlanRC involved longtime residents, new residents, seniors, youth, clubs, organizations, business owners, developers, and many more. As a city rich in its mix of ethnicities, cultures and identities, the engagement for PlanRC worked to provide consistent equitable and inclusive community engagement practices throughout the process. Page 8 Although in-person outreach was extremely limited due to COVID-19 constraints, the community adapted and found meaningful ways to get involved in PlanRC through digital engagement platforms. Engagement efforts prioritized determining values and ideas for the future of the city related to land use, housing, mobility, recreation, and economic development. There were several online surveys, events, and workshops that focused solely on community character, land use, and placemaking, which are implemented by the zoning and standards in the Development Code. Throughout the two-year process, PlanRC received input from over 2,300 community members through online surveys and virtual meetings and generated over 1.1 million digital impressions through various social media platforms. The Development Code, in particular the Form-Based Code, is one of the implementing tools for the General Plan vision, and therefore reflects the ideas, values and input of the community. Development Code Update Focus Group Meeting In addition to the significant amount of community input received during the PlanRC process, staff also conducted a virtual Development Code Update Focus Group Discussion on November 3, 2021. This focus group meeting included Building Industry Association (BIA) members and several developers. The intent of the meeting was to inform and engage key stakeholders about the Development Code update and collect feedback on the current code and opportunities for improvement. Some input received from stakeholders that were addressed in the development code included suggestions for lower guest parking requirements, allowing for shared parking between uses in mixed use areas and flexibility in design for accommodating parking as well as recommendations for future development of parking management plans. In addition, stakeholders requested clear process requirements and objective standards that provide more certainty in desired outcome and streamlining in development review, and more flexibility in certain lot and site planning requirements without having to do a zone change or code amendment. The public review draft of the Development Code and Zoning Map were published to the City’s website on April 7, 2022. This item was also noticed in the Inland Valley Daily Bulletin on April 18, 2022 with an 1/8th page legal ad. In addition, a study session was held with the Planning Commission on April 13, 2022. ENVIRONMENTAL REVIEW: In approving the General Plan update in December 2021, the City Council certified the Rancho Cucamonga General Plan Final Environmental Impact Report (EIR) (SCH No. 2021050261) in accordance with the California Environmental Quality Act (CEQA). Pursuant to CEQA Guidelines Section 15164, the City has reviewed the proposed Development Code Update against the General Plan EIR and determined the EIR adequately addresses all the environmental issues associated with the project. The proposed project would not result in any new significant impacts on the environment based upon the analysis and conclusions presented in the General Plan EIR. In addition, previously identified significant impacts would not be substantially more severe than shown in the previous EIR. Finally, no new feasible mitigation measures have been identified that would substantially reduce significant impacts identified in the General Plan EIR. Therefore, staff has prepared an EIR Addendum (Attachment 2) for the Development Code Update. Unlike an EIR, an Addendum is not required to be circulated for public review. FISCAL IMPACT: The adoption of these new interim standards will facilitate future development consistent with the vision outlined in the General Plan. The General Plan vision for denser, mixed use urban centers can help Rancho Cucamonga maintain a high level of fiscal performance and become a regional destination and focal point of activity. Page 9 COUNCIL MISSION / VISION / GOAL(S) ADDRESSED: Updating the Development Code and Zoning Map to implement the General Plan and Housing Element achieves multiple City Council Core Values, including providing and nurturing a high quality of life for all, promoting and enhancing a safe and healthy community for all, and intentionally embracing and anticipating the future, building and preserving a family-oriented atmosphere, and more. Furthermore, these updates support the City Council’s goal of completing the General Plan and Housing Element. EXHIBITS: Exhibit A – Public Review Draft Development Code Exhibit B – Public Review Draft Zoning Map Exhibit C – EIR Addendum Exhibit D – Resolution Exhibit A The Public Review Draft of the Development Code is available online for review at: Public Review Draft Development Code (Title 17) Hillside Rd Banyan St 19th St Base Line Rd Foothill Bl Arrow Rt 8th St > <( Q) > e CJ C: .ro Q) ro le;) • l -------- > <( Cll >, Q) C: > 4th St � C: ro E Q) I > <( C: ro E Q) I > <( -0 ro _Q .c: 0,._ <( ■1111111111111111111!, .... ,� .. � ''"''''''""m'J.I■ I Ill!! !!111111: � :.. ,ii ;;111111: ;; •............... �.., ■I1111,lliil > <( ro 1/) 0 E ,._ Q) I ii _,1111111111111••"'''"''"�"''"'"" .. , .. ,!IUIH "''""'""'""• ,,1111111" 1111"� 111111 11mn111111m,�:� ••'"""" '"'" 111111 •""""''""" ,,111111• """""" > <( C: Q) > ro I --_, -.,.. -.,,. .-------------.i·• 11111111111,, .... 111111111• = �•• 1u11111■: S,�,:��mm:r: �Jin\ ,111,, S.,,1111 ... , .. f:: ,. .. ,1111111r,:-$ ............ ;: � ... 111111'1 ......... 11,t; , .... 111111, ltr,,"111 lllllf; ........... �II 1■rf ...... Ill'. • ■ ■■-■--=·•···............ r•1111-............ . ;1,.;;11 ·-.............. • i=■I !!111i ■■II■ I • 111 - r, -•- ·----, . -- � Q) 1/) Q) .c: 0 Ill •••• •ri_, -· .... tir1 ■I ■ I••·-· =... ; Ill ··••! � - ■ -= - ' ' :,11!:i: :.,r• ====== '!tn11nu:i 1!'1111 111111..... 111111 llllfl 1111,:j 0:.1,1111111 • �•1111111111 : ........... ..... 11111 1111.II! 0:.11111 .... ;! �11111 1111� ,.,1111111 11no."I f11111 111111 : 111111111111 ;:; ......... = if�III llllll,ii ••i.::=i..:: =�"ill •-------' ............. .., •. 11111 1111111, .............. ,, r •:!11111 1111111111 -............ . : l"IIIIII HJ•� -....... , .. ,�.· : .... 111111 .. ,. : .. ;. ■ -· _I-----------------------------------------i r -------------------------------· > > <( I.() > <( <( C: � ' Q) Q)ro --0 -"' 1/) C: Q) ro .c: -� � 0 0 - 0::: w Ill > <( -1/) ro w Base Line Rd Foothill Bl ----------= ----------------I I ,I lj 1, !1 SR-210 Rancho Zoning Map Zones ----------- OS Open Space HR Hillside Residential OS Open Space, FC Flood Control, UC Utility Corridor VL Very Low Residential EHNCP L Low Residential LM Low Medium Residential M Medium Residential MH Medium High Residential H High Residential NI Neo Industrial GI General Industrial Form Based Zones -NG3 Neighborhood General 3 Zone----COl Corridor 1 Zone CO2 Corridor 2 Zone NG3-L Neighborhood General 3 -Limited CEl Center 1 Zone CE2 Center 2 Zone -Center 2 Limited ME2 Mixed Employment 2 Zone MEl Mixed Employment 1 Zone -NE2 Neighborhood Estate 2 Subzones 1222] 1222] --VL-EH 9000 Very Low Residential -Etiwanda Highlands 9000 VL-EH 14000 Very Low Residential -Etiwanda Highlands 14000 L-ESP Low Residential -Etiwanda Specific Plan LM-ESP Low Medium Residential -Etiwanda Specific Plan --LM-ESP South Low Medium Residential -Etiwanda Specific Plan South M-ESP Medium Residential -Etiwanda Specific Plan- 1222] M-ESP South Medium Residential -Etiwanda Specific Plan South LM-TV Low Medium Residential -Terra Vista M-TVl Medium Residential -Terra Vista 1 M-TV2 Medium Residential -Terra Vista 2 1222] � 1222] MH-TV Medium High Residential -Terra Vista � H-TV High Residential -Terra Vista Overlays •= :1 Cucamonga Station Overlay •= :1 Equestrian Overlay •= :1 Hillside Overlay Per Ord. 628 ':. : Senior Housing Overlay Specific Plans [IIl The Resort Specific Plan [IIl Etiwanda Heights Neigborhood Conservation Plan Master Plans E::I Victoria Gardens Master Plan Corridor Frontages -Corridor Fronting Retail -Corridor Fronting Commercial = Corridor Fronting Residential -F reeway - -· City Limits N 0 0.25 1 .. 0.5 2 , 2 0 0 1 f e e t Miles 1.5 The geographic information available by and through City of Rancho Cucamonga is presented as a public resource of general information. The information may include both map data and data provided by applications. While the City of Rancho Cucamonga strives to maintain the accuracy of the content of its data files, it makes no claims, promises, or guarantees about the accuracy, completeness, or adequacy of the contents of the files. The City of Rancho Cucamonga assumes no responsibility arising from use of the information provided. No warranty of any kind, expressed or implied, including but not limited to, the implied warranties of merchantability and fitness for particular purposes is made. It is the responsibility of the recipient of this data to determine that the level of accuracy meets the needs of their application prior to making any judgments or decisions based on this information. Do not make any business decisions based on this data before validating your decision with the City of Rancho Cucamonga. RESOLUTION NO. 22-14 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA, RECOMMENDING APPROVAL OF (1) A MUNICIPAL CODE AMENDMENT TO AMEND THE DEVELOPMENT CODE IN ITS ENTIRETY TO IMPLEMENT THE GOALS AND POLICIES OF THE GENERAL PLAN, ADOPT A FORM BASED CODE FOR SPECIFIED AREAS, INCLUDE OBJECTIVE DESIGN STANDARDS, AND STAFF IDENTIFIED ISSUES; (2) A ZONING MAP AMENDMENT TO ADOPT A NEW ZONING MAP FOR THE CITY; (3) REPEAL THE FOLLOWING SPECIFIC PLANS, MASTER PLANS AND PLANNED COMMUNITIES: ETIWANDA HIGHLANDS PLANNED UNIT DEVELOPMENT, ETIWANDA NORTH SPECIFIC PLAN, ETIWANDA SPECIFIC PLAN, TERRA VISTA COMMUNTIY PLAN, TOWN SQUARE MASTER PLAN, VICTORIA ARBORS MASTER PLAN, AND VICTORIA COMMUNITY PLAN; (4) A SPECIFIC PLAN AMENDMENT TO AMEND THE BOUNDARIES OF THE EMPIRE LAKES SPECIFIC PLAN (FORMERLY KNOWN AS THE IASP SUB AREA 18 SPECIFIC PLAN) AND RENAME TO THE RESORT SPECIFIC PLAN; AND (5) AN ADDENDUM TO THE CERTIFIED EIR FOR THE PLAN RC GENERAL PLAN ADOPTED IN 2021, AND MAKING FINDINGS IN SUPPORT THEREOF A. Recitals. 1. The City of Rancho Cucamonga has prepared a set of amendments, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Municipal Code Amendment is referred to as “the Amendments”. 2. On April 27, 2022, the Planning Commission of the City of Rancho Cucamonga conducted a noticed public hearing on the application and concluded said hearing on that date. 3. All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved by the Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A of this Resolution, are true and correct. 2. Based upon the substantial evidence presented to the Planning Commission during the above-referenced public hearing on April 27, 2022, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a. The City adopted a new General Plan, Climate Action Plan and Housing Element on December 15, 2021; b. State law requires cities to adopt development or zoning codes that are consistent with their General Plan; PLANNING COMMISSION RESOLUTION NO. 2022-14 DEVELOPMENT CODE UPDATE - CITY OF RANCHO CUCAMONGA April 27, 2022 Page 2 c. The City is proposing to amend its current Development Code, Zoning Map and related special planning documents to be consistent with the adopted General Plan; d. The City prepared the Amendments, which are included as Attachments A and B to this Resolution and are hereby incorporated by this reference as if set forth in full; e. The proposed Development Code Amendment, Zoning Map Amendment, amendment of special planning documents (Specific Plans, Master Plans, and Planned Communities) conform to and do not conflict with the General Plan, including without limitation, the Land Use Element thereof (as amended), and will provide for development in a manner consistent with the General Plan; f. The Development Code Amendment and Zoning Map Amendment are also consistent with the proposed Planning Community, Specific Plan, and Master Plan amendments included herein. 3. Pursuant to the California Environmental Quality Act (“CEQA”) and the City’s local CEQA Guidelines, an addendum to the General Plan Program Environmental Impact Report (SCH #2021050261) has been prepared. The addendum concludes that the proposed changes do not result in any new significant environmental effects or a substantial increase in the severity of previously identified significant effects beyond what was analyzed in the certified EIR. No new information has become available and no substantial changes to the circumstances under which implementation of the General Plan was being undertaken since the certification of the EIR have occurred. The proposed project would not substantially increase the severity of effects relative to the environmental topics analyzed in the Certified EIR, nor would the project require new mitigation measures or alternatives. As a consequence, an addendum is the appropriate level of environmental review. Based on this evidence and all the evidence in the record, the Planning Commission concurs with the Planning Department staff’s determination that the Amendment will not have a significant effect on the environment and is therefore exempt from further environmental review under CEQA. The Planning Commission recommends that the City Council adopt the proposed addendum. 4. Based upon the findings and conclusions set forth in paragraphs 1, 2, and 3 above, this Commission hereby recommends that the City Council approve the Municipal Code Amendment as indicated in Attachment A incorporated herein by this reference. 5. Based upon the findings and conclusions set forth in paragraphs 1, 2, and 3 above, this Commission hereby recommends that the City Council approve the Zoning Map Amendment as indicated in Attachment B incorporated herein by this reference. 6. Based upon the findings and conclusions set forth in paragraphs 1, 2, and 3 above, this Commission hereby recommends that the City Council repeal the Etiwanda Highlands Planned Unit Development, Etiwanda North Specific Plan, Etiwanda Specific Plan, Terra Vista Community Plan, Town Square Master Plan, Victoria Arbors Master Plan, and Victoria Community Plan. 7. Based upon the findings and conclusions set forth in paragraphs 1, 2, and 3 above, this Commission hereby recommends that the City Council approve a Specific Plan Amendment amending the boundaries of the Empire Lakes Specific Plan (previously called the IASP Sub-Area 18 Specific Plan) and renaming the plan The Resort Specific Plan as indicated in Attachment C incorporated herein by this reference. PLANNING COMMISSION RESOLUTION NO. 2022-14 DEVELOPMENT CODE UPDATE - CITY OF RANCHO CUCAMONGA April 27, 2022 Page 3 8. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 27TH DAY OF APRIL 2022. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: Bryan Dopp, Chairman ATTEST: Matthew R. Burris, AICP, Secretary I, Matthew R. Burris, Secretary of the Planning Commission for the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 27th day of April 2022, by the following vote-to-wit: AYES: COMMISSIONERS: NOES: COMMISSIONERS: ABSENT: COMMISSIONERS: ABSTAIN: COMMISSIONERS: PLANNING COMMISSION RESOLUTION NO. 2022-14 DEVELOPMENT CODE UPDATE - CITY OF RANCHO CUCAMONGA April 27, 2022 Page 4 Attachment A – Development Code Amendment The Public Review Draft of the Development Code is available online for review at: Public Review Draft Development Code (Title 17) PLANNING COMMISSION RESOLUTION NO. 2022-14 DEVELOPMENT CODE UPDATE - CITY OF RANCHO CUCAMONGA April 27, 2022 Page 5 Attachment B – Zoning Map Amendment PLANNING COMMISSION RESOLUTION NO. 2022-14 DEVELOPMENT CODE UPDATE - CITY OF RANCHO CUCAMONGA April 27, 2022 Page 6 Attachment C – Revised Boundaries of The Resort Specific Plan March 2022 | General Plan EIR Addendum ADDENDUM TO THE GENERAL PLAN EIR SCH No. 2021050261 FOR THE INTERIM DEVELOPMENT CODE/ZONING STANDARDS City of Rancho Cucamonga Prepared for: City of Rancho Cucamonga Contact: Jennifer Nakamura Deputy Director of Planning 10500 Civic Center Drive Rancho Cucamonga, California 91730 909.477.2700 Prepared by: PlaceWorks Contact: Mark Teague, AICP, Managing Principal 3 MacArthur Place, Suite 1100 Santa Ana, California 92707 714.966.9220 info@placeworks.com www.placeworks.com Exhibit D ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA Table of Contents March 2022 Page i Section Page 1. ADDENDUM TO THE ADOPTED GENERAL PLAN EIR ............................................................... 3 1.1 BACKGROUND .................................................................................................................................................... 3 1.2 PURPOSE OF AN EIR ADDENDUM ........................................................................................................... 3 1.3 PROJECT DESCRIPTION ................................................................................................................................. 5 1.4 GENERAL PLAN EIR ........................................................................................................................................ 9 2. CEQA ANALYSIS ............................................................................................................................ 1 2.1 ENVIRONMENTAL ANALYSIS ..................................................................................................................... 1 2.2 FINDINGS ............................................................................................................................................................. 1 Tabl es Page TABLE 1 SPECIFIC PLANS AND MASTER PLANS REVISED OR REPEALED WITH ZONING CODE UPDATE ................................................................................................................................................................. 6 TABLE 2 TABLE 2. GENERAL PLAN MODIFY EXISTING ZONING .............................................................. 9 Figures Page ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA Table of Contents Page ii March 2022 This page intentionally left blank. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR Page 3 March 2022 1. Addendum to the Certified General Plan EIR 1.1 PURPOSE This document serves as the environmental documentation for adoption of the Interim Development Code (project, proposed project) and Zoning Map to be in compliance with the General Plan. This document is an addendum to the General Plan Environmental Impact Report (EIR), certified on December 15, 2021 (State Clearinghouse Number 2021050261), which demonstrates that the analysis in the General Plan EIR adequately addresses the potential physical impacts associated with implementation of the proposed project and that none of the conditions described in the California Environmental Quality Act (CEQA) Guidelines, Section 15162, exist and preparation of a subsequent EIR or negative declaration is not necessary. 1.2 BACKGROUND On December 15, 2021, the Rancho Cucamonga City Council certified the environmental impact report and adopted the updated General Plan for the City of Rancho Cucamonga (City). The General Plan is the City’s blueprint, or constitution, for future development. The General Plan documents the City’s long-range vision and established clear goals, objectives, and actions to guide the community through the next 20 years. While the General Plan is the policy document that provides an overall vision, policy direction, and implementation strategy to support future development in Rancho Cucamonga, the development code implements general plan policies through detailed development regulations, such as specific use types and building standards. Although the purpose and intent of zoning is different from the General Plan, State law requires that zoning be consistent with maps and policies in the General Plan. Uses and densities/intensities are permitted if they are consistent with both the General Plan land use designation and the zoning of the property. When a zoning ordinance becomes inconsistent due to a general plan amendment, the city must enact a consistent zoning ordinance within a reasonable time. The current development code is not consistent with the intent of the character-based General Plan Land Use Designations and does not contain the necessary standards to implement the General Plan vision for walkable, mixed-use places. As a result, proposed Interim Development Code is designed to implement the Land Use Designations in the General Plan, including the addition of form-based code components for the new mixed- use place types established in the General Plan. As the City is under development pressure to implement the newly adopted General Plan, the adoption of the Interim Development Code as an urgency ordinance will allow the City to begin implementing the General Plan immediately. 1.3 Purpose of an EIR Addendum According to CEQA Guidelines Section 15164(a), an addendum shall be prepared if some changes or additions to a previously certified EIR are necessary, but none of the conditions enumerated in CEQA Guidelines ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR Page 4 March 2022 Sections 15162(a)(1) to (3) calling for the preparation of subsequent EIR have occurred. As stated in CEQA Guidelines Section 15162 (Subsequent EIRs and Negative Declarations): When an EIR has been certified or negative declaration adopted for a project, no subsequent EIR shall be prepared for that project unless the lead agency determines, on the basis of substantial evidence in the light of the whole record, one or more of the following: (1) Substantial changes are proposed in the project which will require major revisions of the previous EIR or negative declaration due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects; (2) Substantial changes occur with respect to the circumstances under which the project is undertaken which will require major revisions of the previous EIR or negative declaration due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects; or (3) New information of substantial importance, which was not known and could not have been known with the exercise of reasonable diligence at the time the previous EIR was certified as complete or negative declaration was adopted, shows any of the following: (a) The project will have one or more significant effects not discussed in the previous EIR or negative declaration; (b) Significant effects previously examined will be substantially more severe than shown in the previous EIR; (c) Mitigation measures or alternatives previously found not to be feasible would in fact be feasible and would substantially reduce one or more significant effects of the project, but the project proponents decline to adopt the mitigation measure or alternative; or (d) Mitigation measures or alternatives which are considerably different from those analyzed in the previous EIR would substantially reduce one or more significant effects on the environment, but the project proponents decline to adopt the mitigation measure or alternative. The proposed project would not trigger any of the conditions outlined in CEQA Guidelines Sections 15162(a)(1) to (3) because these changes would not result in new significant environmental effects or a substantial increase in the severity of previously identified significant effects requiring major revisions to the General Plan EIR. The following analysis provides the substantial evidence required by CEQA Guidelines Section 15164(e) to support the finding that a subsequent EIR is not required and an addendum to the General Plan EIR is the appropriate environmental document to address changes to the project. As stated in CEQA Guidelines Section 15164 (Addendum to an EIR): (a) The lead agency or responsible agency shall prepare an addendum to a previously certified EIR if some changes or additions are necessary but none of the conditions described in Section 15162 calling for preparation of a subsequent EIR have occurred. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR March 2022 Page 5 (b) An addendum to an adopted negative declaration may be prepared if only minor technical changes or additions are necessary or none of the conditions described in Section 15162 calling for the preparation of a subsequent EIR or negative declaration have occurred. (c) An addendum need not be circulated for public review but can be included in or attached to the final EIR or adopted negative declaration. (d) The decision-making body shall consider the addendum with the final EIR or adopted negative declaration prior to making a decision on the project. (e) A brief explanation of the decision not to prepare a subsequent EIR pursuant to Section 15162 should be included in an addendum to an EIR, the lead agency's findings on the project, or elsewhere in the record. The explanation must be supported by substantial evidence. A copy of this addendum, and all supporting documentation, may be reviewed or obtained at the City of Rancho Cucamonga Planning Department, 10500 Civic Center Drive, Rancho Cucamonga, California 91730. 1.4 PROJECT DESCRIPTION The proposed project is to adopt an Interim Development Code to implement the Land Use Designation in the General Plan as an urgency ordinance. The Interim Development Code contains provisions to ensure that land development is consistent with the policy direction of the General Plan. As the current Development Code was comprehensively updated in 2012, the recommendations included in the proposed project include amendments to standards and requirements within the existing structure and format of the Code (Development Code Update City of Rancho Cucamonga, page 3). These recommendations include topics such as General Plan Implementation and General Code Issues, Mixed-Use and Multi-Family Objective Design Standards, and Specific Plan and Master Plan Analysis. The fundamental elements of the Development Code update are: • Integrating and modifying the form-based and conventional zones. • New form-based zoning regulations for walkable mixed-use areas along Foothill Boulevard and other key corridors. • Incorporation of appropriate standards from older Specific Plans and Planned Communities into the new zoning regulations to allow for repeal of outdated plans. • New objective design standards for multi-family residential and mixed-use development projects to respond to changes in state law and facilitate housing production. • Improved administration and permit procedures to streamline development review for projects consistent with the General Plan and ensure adequate tools for enforcement of the Development Code. The implementation of the General Plan is generally managed by the Development Code (Title 17 of the Rancho Cucamonga Municipal Code). The Development Code includes zoning districts consistent with the General Plan and applies development standards to each zoning district that guide site layout, key design elements, and development intensity. The proposed project also includes objective design standards for mixed used and multi-family development as form-based elements that will be applied to base zoning districts. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR Page 6 March 2022 As shown below in Table 1. Specific Plans and Master Plans Revised or Replaces with Interim Zoning Code Update and referenced in the General Plan EIR (Land Use and Planning, page 5.11-16), several of the existing plans in the city would be reappealed and changed to comply with the new standards of the Interim Development Code Update. Table 1. Specific Plans and Master Plans Revised or Repealed with Interim Zoning Code Update Plan/Year Adopted or Amended Notes on Review Empire Lakes Specific Plan (ELSP) (Also referred to as IASP Sub-Area 18 Specific Plan) 1994 adopted/2016 last revised Amend the ELSP boundary to cover area as required by the Development Agreement, with those regulations, requirements, and standards remaining in place. The remaining ELSP areas will be regulated by policy and standards in the General Plan Update. Areas regulated by the General Plan Update will be implemented with the citywide code (including new form-based districts, and design standards). Etiwanda Highlands Planned Unit Development (EH) 1988 Repeal – Develop two new zone districts (e.g., VL- EH 9000 and VL-EH 14000) to regulate this area, consistent with the standards in the existing Planned Unit Development (PUD). Standards not regulated by the PUD would be regulated in the new zone districts. All other standards and procedures applicable to the VL District would apply to the VL-EH Districts. Etiwanda North Specific Plan (NESP) 1992 Repeal – A portion of this Plan area was amended and now regulated by the Etiwanda Heights Specific Plan. The portion identified for low density residential can be regulated by the existing Low Residential District standards. The remaining area will be regulated by the Traditional Neighborhood Land Use Designation and subsequent zoning district and the zoning that replaces the Etiwanda Highlands Planned Unit Development (see above). Etiwanda Specific Plan (ESP) 1985 adopted/2000 last revised Repeal – A small area will be regulated by the new form-based zoning district based on General Plan placetype. Regulate the Very Low density area with the existing Very Low Residential District. Create new zone districts to regulate the remaining areas consistent with the standards in the Specific Plan. Terra Vista Community Plan (TCVP) 1983 adopted/1995 last revised Repeal – The Plan Area along Foothill Boulevard will be regulated by the new form- based zoning district based on the General Plan Update. The remaining area is a combination of Low Medium, Medium, Medium High, and High zoning districts. Create new zone districts to regulate the remaining areas consistent with the standards in the TCVP. Town Square Master Plan (TS) 2002 Repeal – This area to be regulated by policy and standards in the General Plan Areas regulated by the General Plan will be implemented with the citywide code (including new form-based districts, and design standards, as applicable). Victoria Arbors Master Plan (VA) 2002 See VCP below. Victoria Arbors Master Plan overlaps with the VCP. Victoria Community Plan (VCP) 1981 Repeal – A portion will be regulated by the applicable new form-based zoning district based on General Plan placetype. For the remainder, the existing Low and Low Medium Residential zoning districts will be applied based on the designation in the VCP. The Mixed Use overlay will also be deleted as part of this effort. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR March 2022 Page 7 The Interim Development Code update includes modifications to existing zoning districts as well as new zoning districts with form-based code components. Table 2, General Plan Modifying Existing Zoning Districts, displays the following recommended zoning districts to implement each of the General Plan land use designations and if modifications or new zoning districts are needed (Interim Development Code Update, 5). Recommendations to implement the General Plan and create new zones to implement the new mixed-use land use designations are provided in Section 2.B of the Interim Development code update (Interim Development Code update, 5). Other changes to existing zoning districts may be recommended based on an assessment of General Plan policies in Appendix A of the Interim Development Code update. Appendix A is used to identify inconsistencies between the General Plan and the City’s Development Code and provide recommendations to resolve those inconsistencies (Interim Development Code Update, A-1). The Interim Development Code will facilitate development in zoned properties and bring them into compliance with the General Plan. While zoning districts will change, the development potential and impacts are already addressed in the General Plan EIR. In most cases, there are development standards for any new permitted use that would not be subject to CEQA review. However, development policies, programs, ordinances, and permits that define the development process would still apply. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR Page 8 March 2022 Table 2. General Plan Modify Existing Zoning General Plan Land Use Designation Implementing Zone Recommendation Neighborhood Place Type Semi-Rural Neighborhood Very Low Residential (VL) Modify to allow multi-family, civic and neighborhood serving commercial consistent with General Plan Traditional Neighborhood TBD Discuss with City the possibility of modification of EHNCP Zones to apply Requires additional microscale analysis in residential areas Suburban Neighborhood – Very Low Low (L) and/or Low Medium Residential (LM) Modify maximum allowed density consistent with General Plan consistent with General Plan Suburban Neighborhood- Moderate High Residential (H) Modify to ensure limited neighborhood commercial uses allowed consistent with General Plan Urban Neighborhood FBC: Urban Center New Zone consistent with General Plan Corridor Place Type Neighborhood Corridor FBC: Neighborhood General New Zone consistent with General Plan City Corridor - Moderate FBC: General Urban New Zone consistent with General Plan City Corridor – High FBC: Urban Corridor New Zone consistent with General Plan District Place Type 21st Century Employment District FBC: General Urban New Zone consistent with General Plan Office Employment District Office Professional (OP) and or Commercial Office (CO) combination Modify to allow mixed use, multi-family, increase height/density, and reduce setbacks consistent with General Plan ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA Addendum to the Adopted General Plan EIR March 2022 Page 9 1.5 GENERAL PLAN EIR The General Plan EIR found that, with the implementation of policies and actions from the General Plan and mitigation measures identified in the EIR, there would be less than significant impacts related to aesthetics, energy, geology and soils, hazardous materials, hydrology/water quality, land use/planning, mineral resources, population/housing, public services, recreation, tribal cultural resources, utilities and services, and wildfire. As the proposed project is intended to align the Development Code and Zoning map with the General Plan, implementation of policies and actions from the General Plan and mitigation measures identified in the EIR would have the same mitigating effect under the Interim Development Code and impacts would also be less than significant. Table 3 lists the significant and unavoidable impact determinations of the General Plan EIR and compares the resulting impacts of the proposed project to those determinations. The General Plan EIR determined that implementation of the General Plan would result in significant and unavoidable impacts to agriculture/forest resources, air quality, biological resources, cultural resources, greenhouse gas emissions, noise, and transportation. As described below, the proposed project would be within the scope of analysis of the General Plan update identified in the EIR. The proposed project would incorporate all applicable General Plan policies and implementation measures for significant and unavoidable impacts identified in Table 3 and would not create a new significant impact or a substantial increase in the severity of previously identified effects. Table 3: General Plan EIR Significant and Unavoidable Impacts and Impacts of the Proposed Project Environmental Topic Significant and Unavoidable Impact Determination Resulting Impact of the Proposed Project Agriculture and Forest Resources Impact 5.2-1: The proposed project would convert Farmland to non- agricultural uses but would not result in the conversion of forest land to non-forest uses. [Thresholds AG-1 and AG-5] The proposed project would not allow development of land that was not considered for development under the General Plan. While current vineyards and orchards would be converted into urban uses as part of future anticipated development, they would not impact land not considered for development in the General Plan EIR. There proposed project would not have an effect in forest lands because there are no lands that qualify as forest or timberland. Air Quality Impact 5.3-2: The proposed project would cause construction-generated criteria air pollutant or precursor emissions to exceed South Coast AQMD-recommended thresholds. [Threshold AQ-2] Impact 5.3-3: The proposed project would result in a net increase in long- term operational criteria air pollutant and precursor emissions that exceed South Coast AQMD-recommended thresholds. [Threshold AQ- 2] Impact 5.3-5: The proposed project would expose sensitive receptors to substantial increases in toxic air contaminant emissions. [Threshold AQ- 3] The General Plan Update would accommodate future development of single-family and low-rise multifamily residential, retail, hotel, office, art/entertainment/recreation, and industrial land uses. The proposed project would not change the type of development assumed in the General Plan EIR and impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. The future development and other physical changes that could result from implementation of the Interim Development Code would generate construction-related emissions of criteria air pollutants and precursors. The proposed project would not change the type of development assumed in the General Plan EIR and impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. The implementation of the Interim Development Code could result in exposure of sensitive receptors due to construction-related TAC. However, the proposed project would not change the type of development assumed in the General Plan EIR and impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR Page 10 March 2022 Environmental Topic Significant and Unavoidable Impact Determination Resulting Impact of the Proposed Project Biological Resources Impact 5.4-1: Buildout of the proposed Land Use Plan would impact sensitive plant and animal species known to occur in the City of Rancho Cucamonga. [Threshold B-1] Implementation of the Interim Development Code could impact special status vegetation or special status wildlife in the city. However, the proposed project would not change the type or location of development assumed in the General Plan EIR and impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. Cultural Resources Impact 5.5-1: Buildout of the City of Rancho Cucamonga General Plan could impact historic resources. [Thresholds C-1] Implementation of the Interim Development Code could adversely impact some of these historic resources. However, the proposed project would not change the type or location of development assumed in the General Plan EIR and impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. Greenhouse Gas Emissions Impact 5.8-4: The proposed project would be inconsistent with the State’s ability to achieve the long-term reduction goals or Executive Orders S-3-05, B-30-15, and B-55-18. [Threshold GHG-2] Implementation of the Interim Development Code could result in the generation of greenhouse gases. However, the proposed project would not change the type or location of development assumed in the General Plan EIR and impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. Noise Impact 5.13-1: Construction activities would result in temporary noise increases in the vicinity of the future development under the General Plan. [Threshold N-1] Impact 5.13-2: Project implementation could generate a substantial permanent increase in traffic noise levels at noise-sensitive land uses in excess local standards. [Threshold N-2] Impact 5.13-4: Expose new sensitive land uses to noise levels in excess of the noise compatibility standards identified in 2040 General Plan Noise Element Table N-1. [Threshold N-4] Impact 5.13-5: Future development under the General Plan could generate short-term construction vibration or exposure to new sensitive land uses to long-term operational vibration sources that exceed City thresholds. [Threshold N-5] The City has established standards for acceptable noise levels in Section 17.66.050 that are consistent with the Development Code update. Because the proposed project would not change the type or location of development assumed in the General Plan EIR and noise impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. Traffic noise modeling was conducted for existing (2021) and future (2040) conditions using traffic data generated for the 2040 General Plan, which was based on anticipated land use development contemplated under buildout conditions through 2040. Because the proposed project would not change the type or location of development assumed in the General Plan EIR and noise impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. New development associated with the 2040 General Plan could potentially be near existing roadways and existing or future planned railroads. Because the proposed project would not change the type or location of development assumed in the General Plan EIR and noise impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. Implementation of standard conditions of approval 5.13-5b and 5.13-5c, which require project-specific vibration analyses to evaluate vibration exposure from nearby transit sources and evaluation of potential vibration impacts from new transit projects would still be required under the Interim Development Code. Therefore, noise impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA Addendum to the Adopted General Plan EIR March 2022 Page 11 Environmental Topic Significant and Unavoidable Impact Determination Resulting Impact of the Proposed Project Transportation Impact 5.17-2: The project may be inconsistent with CEQA Guidelines section 15064.3, subdivision (b) regarding policies to reduce VMT. [Threshold B-2] Implementation of the Interim Development Code could result in changes to the vehicle miles traveled by residential and non-residential development in the City. However, the proposed project would not change the type or location of development assumed in the General Plan EIR and VMT-related impacts associated with implementation of the Interim Development Code would be the same as that analyzed in the General Plan EIR.. ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA March 2022 Page 14 2. CEQA Analysis 2.1 ENVIRONMENTAL ANALYSIS The General Plan contains policies related to land use and community character, focus areas, open space, mobility and access, housing, public facilities and services, resource conservation, safety, and noise. As previously described in Section 1.4 and referenced in Table 3, the General Plan EIR addresses potentially significant impacts related to agriculture and forestry, air quality, cultural resources, greenhouse gas emissions, noise, and transportation. The policies of the General Plan and the existing development standards apply to all development in the General Plan and would continue to apply to the land that is the subject of the proposed project. The proposed zoning changes are intended to align the City’s Municipal Code and Zoning Map with the land use designations and policies and implementation measures with the General Plan and will replace or amend specific plans and master plans previously adopted. Therefore, these changes would not result in significant changes to the existing land uses and or development standards as compared to that analysis in the General Plan EIR. The modification to the specific and master plans in the General Plan EIR is consistent with the specific design standards and guidelines in the Development Code update (Development Code Update, Appendix-H). The General Plan EIR anticipates growth in focused areas of the community that are already designated for development (Project Description, 3-2). The Land Use & Community Character in Section 5.11 Land Use and Planning details policy changes for different place types. These focus areas will increase housing and building intensity as well as create more urban spaces (Land Use and Planning, 5-11-7). The General Plan EIR suggests Volume 4 Implementation Strategy recommends policy change in the development code changes. (Project Description, 3-3) Chapter 3, Project Description of the General Plan EIR, considers anticipated growth for existing and proposed General Plan Designation as listed in Table 2. General Plan Modify Existing Zoning. The Land Use Designations listed in Table 3 -2 Existing and Proposed Land Use Designations of the General Plan EIR display density ranges for mix of existing land use designations that will comprise the new place type; these density ranges are consistent with the recommendations listed in proposed Interim Development Code update (Project Description, 3-6). 2.2 FINDINGS The discussion in this addendum confirms that the proposed project has been evaluated for significant impacts pursuant to CEQA. There are no substantial changes in the circumstances or new information that was not known and could not have been known at the time of the certification of the General Plan EIR. As a result, and for the reasons explained in this addendum, the project would not cause any new significant environmental impacts or substantially increase the severity of significant environmental impacts disclosed in the General Plan EIR. Thus, the proposed project does not trigger any of the conditions in CEQA Guidelines Section 15162 ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA 1. Addendum to the Adopted General Plan EIR Page 13 March 2022 requiring preparation of a subsequent EIR, and the appropriate environmental document as authorized by CEQA Guidelines Section 15164(b) is an addendum. Accordingly, this EIR addendum has been prepared. The following identifies the standards in CEQA Guidelines Section 15162 as they relate to the project. 1. No substantial changes are proposed in the project which would require major revisions of the EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects. The proposed project will align the new zoning districts as shown in the Interim Development Code update with the land use designations including the addition of form-based code components and mixed -use place type descriptions assumed in the General Plan EIR. The proposed changes are consistent with the General Plan as evaluated in the General Plan EIR. Therefore, the updates to the Development code would not change the conclusions of the EIR and would not require revisions to the General Plan EIR due to new significant environmental effects or a substantial increase in the severity of previously identified significant effects. 2. There is no new information of substantial importance, which was not known and could not have been known with the exercise of reasonable diligence at the time the previous EIR was certified as complete demonstrating that the project will have one or more significant effects not discussed in the previous EIR. The policies and implementation measures identified in the General Plan EIR would continue to apply to all development in the city and would have the same effect to reduce or eliminate environmental impacts as disclosed in the General Plan EIR. The amendments to the Development Code were discussed in the General Plan EIR, and there is nothing in the proposed project that was not known and could not have been known at the time the General Plan EIR was certified demonstrating that the project would have one or more significant effects not discussed in the EIR. Therefore, no new impacts would occur because of future development. Because a development project must be consistent with the General Plan, zoning, and development standards of the City, the resulting impacts would be the same as those disclosed in the certified General Plan EIR. 3. There is no new information of substantial importance, which was not known and could not have been known with the exercise of reasonable diligence at the time the previous EIR was certified as complete demonstrating that significant effects previously examined will be substantially more severe than shown in the previous EIR. Implementation of the proposed project would have the same significant impacts as those disclosed in the General Plan EIR. The General Plan policies and implementation measures identified in the General Plan EIR to reduce physical environmental effects would apply to all new development. These policies would have the same effect in reducing or eliminating environmental impacts as disclosed in the General Plan EIR. There is no new information that would demonstrate that significant effects examined would be substantially more severe than shown in the certified General Plan EIR. 4. There is no new information of substantial importance, which was not known and could not have been known with the exercise of reasonable diligence at the time the previous EIR was certified as complete demonstrating that mitigation measures or alternatives previously found ADDENDUM TO THE GENERAL PLAN EIR FOR THE INTERIM ZONING CODE AMENDMENT CITY OF RANCHO CUCAMONGA March 2022 Page 14 not to be feasible would in fact be feasible and would substantially reduce one or more significant effects of the project, but the project proponents decline to adopt the mitigation measure or alternative. The proposed project will align the zoning districts in the City of Rancho Cucamonga with the General Plan Land Use Map as evaluated by the General Plan EIR. All policies and implementation measures identified in the General Plan EIR would continue to apply to all development in the city and would have the same effect in reducing or eliminating environmental impacts as disclosed in the General Plan EIR. The proposed project would not change the assumptions described in the General Plan EIR and, therefore, would not substantially change the conclusions of the EIR or require new mitigation measures. 5. There is no new information of substantial importance, which was not known and could not have been known with the exercise of reasonable diligence at the time the previous EIR was certified as complete demonstrating that mitigation measures or alternatives which are considerably different from those analyzed in the previous EIR would substantially reduce one or more significant effects on the environment, but the project proponents decline to adopt the mitigation measure or alternative. The proposed project changes would not result in an increase of overall development intensity and the resulting impacts would be the same as those disclosed in the certified General Plan EIR. Therefore, no new mitigation measures or alternatives to the proposed project would be required.