HomeMy WebLinkAbout2022-076 - Resolution •
•
•
RESOLUTION NO. 2022-076
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF RANCHO
CUCAMONGA, CALIFORNIA, AMENDING ELECTRIC RATES AND
CHARGES, PURSUANT TO THE REQUIREMENTS AND AUTHORITY OF
CHAPTER 3.46 OF TITLE 3 OF THE RANCHO CUCAMONGA
MUNICIPAL CODE
A. Recitals
1. The City Council of the City of Rancho Cucamonga has previously adopted Chapter 3.46 of
Title 3 of the Rancho Cucamonga Municipal Code establishing Electricity Service Rules and
Regulations and authorizing that the rates,fees and charges arising, directly or indirectly, under
said legislation be adopted pursuant to resolution, and thereafter, be amended from time to
time by resolution.
2. City staff has prepared a comprehensive schedule of the rates, fees and charges that reflect
the reasonable and prudent costs relating to the acquisition and distribution of electric power
to retail customers and are recommending that the City Council adopt the recommended rates
and fees. These rates do not present the City an opportunity to achieve profits or to impose
charges in excess of the costs reasonably related to the development, maintenance and
expansion of a municipal electric distribution system. The City Council has directed City staff
to regularly review the operations of the City's electric utility to ensure that the rates are
sufficient to cover all prudent business costs, reserves and capital equipment acquisition but
not exceeding the amount necessary for the same. The rates, fees and charges reflect the
reasonable costs to the City system only and do not reflect any excess rates, fees, or charges
that are in excess of the reasonable costs of providing the electrical services as set forth
hereinafter.
3. The City Council has reviewed the adoption of this Resolution pursuant to the requirements of
the California Environmental Quality Act of 1970, as amended, and has determined that the
adoption of the Electric Rules and Regulations has no foreseeable potential to a result in a
significant impact upon the environment and is exempt from CEQA review pursuant to State
CEQA Guidelines Section 15061(b)(3). Further, the City Council has determined that the
adoption of the fees is exempt from substantive environmental review under Section 15273 of
the State CEQA Guidelines as no capital projects for system expansion are included in the
proposed action.
4. All legal prerequisites to the adoption of this Resolution have occurred.
B. Resolution
NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF RANCHO CUCAMONGA, HEREBY
RESOLVES,
Section 1.: The facts set forth in the Recitals, Part A of this Resolution, are true and correct.
Section 2.: The rates, fees and charges assessed under Chapter 3.46 of Title 3 shall be as set
forth on Attachment 1 hereto and incorporated by reference as if fully set forth herein on July 1, 2022.
Section 3.: The City Clerk shall certify to the adoption of this Resolution.
Resolution No. 2022-076— Page 1 of 2
PASSED, APPROVED, and ADOPTED this 15th day of June 2022.
. is ichae , Mayor
ATTEST:
nolds, City Clerk
STATE OF CALIFORNIA )
COUNTY OF SAN BERNARDINO ) ss
CITY OF RANCHO CUCAMONGA )
I, Janice C. Reynolds, City Clerk of the City of Rancho Cucamonga, do hereby certify that the
foregoing Resolution was duly passed, approved, and adopted by the City Council of the City of
Rancho Cucamonga, at a Regular Meeting of said Council held on the 15th day of June 2022.
AYES: Hutchison, Kennedy, Michael, Scott
NOES: None
ABSENT: None
ABSTAINED: None
Executed this 16th day of June, 2022, at Rancho Cucamonga, California.
l' Reynolds, City Cler
Resolution No. 2022-076 — Page 2 of 2
ATTACHMENT 1
Table of Contents
Electric Rates and Tariffs
RESIDENTIAL 1
SMALL COMMERCIAL 4
MEDIUM COMMERCIAL 6
MEDIUM COMMERCIAL (TIME-OF-USE) 9
LARGE COMMERCIAL 12
LARGE INDUSTRIAL 15
STREET LIGHTING 18
TRAFFIC CONTROL 21
OUTDOOR AREA LIGHTING 22
IRRIGATION SYSTEMS 24
WIRELESS TECHNOLOGY 25
NET ENERGY METERING 27
ECONOMIC DEVELOPMENT 30
STANDBY DEMAND CHARGE 33
ELECTRIC VEHICLE CHARGING 36
SERVICE ESTABLISHMENT CHARGE 39.
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY.
ELECTRIC RATES&TARIFFS
RESIDENTIAL
A. Applicability
Applicable to individual accommodations devoted primarily to domestic purposes where
service includes lighting, appliances, heating, cooking and power consuming appliances
or combination thereof in a residential accommodation.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge $/kWh/Meter
Summer and Winter
Tier 1 —Baseline Quantities 0.11910
Tier 2— 101%to 130% of Baseline 0.14000
Tier 3 —Over 131% of Baseline 040000.25686
Customer Charge- $/Meter/Day
Single-Family Residence 030.28
Multi-Family Residence 0.2.10.26
D. Special Conditions
1. Summer and Winter Seasons are defined as follows:
The Summer Season shall commence at 12:00 a.m. on June 1st and continue until
12:00 a.m. on October 1st of each year. The Winter Season shall commence at
12:00 a.m. on October 1st of each year and continue until 12:00 a.m. on June 1st
of the following year. A pro rata computation will be made for seasonal billing
purposes.
• 2. Customer Charge: For purposes of applying the Customer Charge, the following
definitions shall be used:
Single-Family Residence: A building of single occupancy, which does not share
common walls, floors, or ceiling with other residential dwelling units.
Multi-Family Residence: Apaitments, mobile homes, condominiums, townhouses
or a building of multiple occupancy which shares common walls and/or floors and
ceilings with other residential dwelling units.
3. Voltage.: Service will be supplied at one (1) standard voltage.
4. Baseline Quantities: The residential allocation shall be 16.1 kWhs per day in
Summer Season and 10.6 kWhs per day in the Winter Season.
1 Proposed Effective Date:July 1,2022.
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
5. Customer-Owned Electrical Generating Facilities.
Upon written approval by the Utility, momentary parallel operation may be
permitted to allow the Customer to test the auxiliary/emergency generating
facilities.
6. Medical Support Assistance
Eligible customers under this schedule upon application and certification from a
medical doctor shall receive a monthly discount to assist customers with doctor-
prescribed life support equipment. To qualify, a customer must submit an
application and satisfactory proof that a full-time occupant of the customer's
residence requires a life support device. A qualifying life support device may be
any one of the following or such other equipment as the Utility may deem
eligible: aerosol tents, apnea monitors, compressors or concentrators, electrostatic
or ultrasonic nebulizers, electric nerve stimulators, hemodialysis machines,
kidney dialysis machines, intermittent positive pressure breathing machines, iron
lungs, pressure pads; pressure pumps, respirators, or suction machines. Customers
must reapply annually to demonstrate eligibility for the discount.
The monthly discount applies to energy charges only. All other charges and taxes
are calculated at the standard rates. Program qualifications and rules are subject
to change and are based on funding availability. In the event the Utility becomes
aware of any false or fraudulent statements or information submitted in writing or
verbally by the Customer, the Utility reserves the right to back bill the Customer
for services rendered under this program.
7. Low Income Assistance
A low-income assistance program is available under this schedule for income
qualified customers. To be considered for this discount, an application must be
filled out with supporting documentation of proof of income. Total combined
gross annual household income, both taxable and nontaxable, must meet the
current income levels of the San Bernardino County (Very Low) Income Limits
Documentation System. Customers must reapply annually to demonstrate
eligibility for the discount.
The monthly discount applies to energy charges only. All other charges and taxes
are calculated at the standard rates. Program qualifications and rules are subject
to change and are based on funding availability. In the event the Utility becomes
aware of any false or fraudulent statements or information submitted in writing or
verbally by the Customer, the Utility reserves the right to back bill the Customer
for services rendered under this program.
8. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh]).
9. Power Cost Adjustment Factor(PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
10. Change of Law Adjustment Factor(CLAF)
2 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY.
ELECTRIC RATES&TARIFFS
The rates above are subject to an adjustment as provided in Rule 12, Section F.
11. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
3 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
SMALL COMMERCIAL
A. Applicability
Applicable to single and three-phase general service including lighting and power
Customers, except for the Customer whose monthly Maximum Demand, in the opinion of
the Utility, is expected to exceed 20 kW or has exceeded 20 kW in any three (3) months
during the preceding twelve (12) months is ineligible for service under this Schedule.
Effective with the date of ineligibility of any Customer served under this Schedule, the
Customer's account shall be transferred to another applicable Rate Schedule.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge $/kWh/Meter/Month - —___
Summer 0.183220.18768
Winter 0.126680.12976
Customer Charge- $/Meter/Day 0792-6
Single Phase 1.00
Three Phase 1.15
D. Special Conditions
1. Summer and Winter Seasons are defined as follows:
The Summer Season shall commence at 12:00 a.m. on June 1st and continue until
12:00 a.m. on October 1st of each year. The Winter Season shall commence at
12:00 a.m. on October 1st of each year and continue until 12:00 a.m. on June 1st of
the following year. A pro rata computation will be made for seasonal billing
purposes.
2. Voltage. Service will be supplied at one (1) standard voltage
3. Temporary Discontinuance of Service
Where the use of energy is seasonal or intermittent, no adjustments will be made
for a temporary discontinuance of service. Any Customer, prior to resuming
service within twelve (12) months after such service was discontinued, will be
required to pay all charges which would have been billed if service had not been
discontinued.
4. Customer-Owned Electrical Generating Facilities
Upon written approval by the Utility, momentary parallel operation may be
permitted to allow the Customer to test the auxiliary/emergency generating
facilities.
4 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
5. Installation of Demand Meters
Where a Customer's usage exceeds an average of 4,500 kWh per month in the
preceding 12-month period, the Utility may, at its sole option, install a demand
Meter on the account at the Utility's expense.
6. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh], demand [kW], etc.).
7. Power Cost Adjustment Factor (PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
8. Change of Law Adjustment Factor(CLAF)
The rates above are subject to an adjustment as provided in Rule 12, Section F.
9. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program, charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
5 s Proposed Effective.Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
MEDIUM COMMERCIAL
A. Applicability
Applicable to single and three-phase service including lighting, and power Customers
whose monthly Maximum Demand registers, or in the opinion of the Utility is expected
to register, above 20 kW and below 200 kW. The Customer whose monthly Maximum
Demand, in the opinion of the Utility, is expected to reach 200 kW or has reached 200
kW for any three (3) months during the preceding twelve (12) months is ineligible for
service under this Schedule. Effective with the date of ineligibility, such Customer's
account shall be transferred to another applicable Rate Schedule. Further, any Customer
served under this Schedule whose monthly Maximum Demand has registered 20 kW or
less for twelve (12) consecutive months is eligible for service under another applicable
Rate Schedule.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh/Meter/Month
Summer Season 0.079410.08359
Winter Season 0.063910.06725
Customer Charge - $/Meter/Month 145.00
Demand Charge - $/kW of Billing Demand/Meter/Month
Facilities Related 14.00
Time Related(Summer) 16.50
D. Special Conditions
1. Summer and Winter Seasons are defined as follows:
The Summer Season shall commence at 12:00 a.m. on June 1st and continue until
12:00 a.m. on October 1st of each year. The Winter Season shall commence at
12:00 a.m..on October 1st of each year and continue until 12:00 a.m. on June 1st of
the following year. A pro rata computation will be made for seasonal billing
purposes.
2. RTEM Metering. Customers may elect a Real Time Energy Metering ( TEM)
y the monthly e a o nd; ated the Rate seetien o f tl,
Rate Schedule.
3. Voltage
Service will be supplied at one (1) standard voltage.
6 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
4. Billing Demand
The Billing Demand shall be the kilowatts of Maximum Demand, determined to
the nearest kW. The Demand Charge shall include the following billing
components. The Time Related Component shall be for the kilowatts of
Maximum Demand recorded during (or established for) the monthly billing
period. The Facilities Related Component shall be for the kilowatts of Maximum
Demand recorded during (or established for) the monthly billing period.
However, when the Utility determines the Customer's Meter will record little or
no energy use for extended periods of time or when the Customer's Meter has not
recorded a Maximum Demand in the preceding eleven (11) months, the Facilities
Related Component of the Demand Charge may be established at fifty percent
(50%) of the Customer's Connected Load.
5. Maximum Demand
The Maximum Demand in any month shall be the measured maximum average
kilowatt input, indicated or recorded by instruments, during any 15-minute
metered interval in the month, but, where applicable, shall not be less than the
diversified resistance welder load computed in accordance with the section
designated Welder Service in Rule 2. Where the demand is intermittent or subject
to violent fluctuations, a 5-minute interval may be used.
6. Temporary Discontinuance of Service
Where the use of energy is seasonal or intermittent, no adjustments will be made
for a temporary discontinuance of service. Any Customer resuming service
within twelve (12) months after such service was discontinued will be required to
pay all charges which would have been billed if service had not been
discontinued.
7. Customer-Owned Electrical Generating Facilities
Upon written approval by the Utility, momentary parallel operation may be
permitted to allow the Customer to test the auxiliary/emergency generating
facilities.
8. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh], demand [kW], etc.).
9. Power Cost Adjustment Factor (PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
10. Change of Law Adjustment Factor(CLAF)
L
The rates above are subject to an adjustment as provided in Rule 12, Section F.
11. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
7 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
projects, and services for low-income electricity customers.
8 Proposed Effective Date:July 1,2022
•
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
MEDIUM COMMERCIAL (TIME-OF-USE)
A. Applicability
Applicable to single and three-phase service including lighting and power Customers
whose monthly Maximum Demand registers, or in the opinion of the Utility is expected
to register 200 kW through 500 kW. The customer whose monthly Maximum Demand,
in the opinion of the Utility, is expected to exceed 500 kW or has exceeded 500 kW for
any three (3) months during the preceding twelve (12) months is ineligible for service
under this Schedule and effective with the date of ineligibility, such Customer's account
shall be transferred to Large Commercial. Further, any Customer served under this
Schedule whose monthly Maximum Demand has registered below 200 kW for twelve
(12) consecutive months is ineligible for service under this Rate Schedule and shall be
transferred to another applicable Rate Schedule.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh/Meter/Month
Summer Season—On-Peak 0.113640.11668
Mid-Peak 0.080640.08368
Off-Peak 0.05340.05618
Winter Season—Mid-Peak 0.057110.06018
Off-Peak 0.010610.04368
Customer Charge - $/Meter/Month 400.00
Demand Charge - $/kW of Billing Demand/Meter/Month
Facilities Related 14.25
Time Related Summer—On-Peak 13.50
Summer—Mid-Peak 3.50
Power Factor Adjustment- $/KVA 0.27
D. Special Conditions
1. Time periods are defined as follows:
On-Peak: Noon to 6:00 p.m. summer weekdays except holidays.
Mid-Peak: 8:00 a.m. to noon and 6:00 p.m. to 11:00 p.m. summer weekdays
except holidays.
8:00 a.m. to 9:00 p.m. winter weekdays except holidays.
Off-Peak: All other hours.
9 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
Holidays are New Year's Day (January 1), Washington's Birthday (third Monday
in February), Memorial Day (last Monday in May), Independence Day (July 4),
Labor Day (first Monday in September), Veteran's Day (November 11),
Thanksgiving Day (fourth Thursday in November), and Christmas (December
25).
When any holiday listed above falls on Sunday, the following Monday will be
recognized as an off-peak period. No change will be made for holidays falling on
Saturday.
The Summer Season shall commence at 12:00 a.m. on June 1st and continue until
12:00 a.m. on October 1 st,of each year. The Winter Season shall commence at
12:00 a.m. on October 1st of each year and continue until 12:00 a.m. on June 1st of
the following year. A pro rata computation will be made for seasonal billing
purposes.
2. Voltage
Service will be supplied at one (1) standard voltage.
3. Billing Demand
The Billing Demand shall be the kilowatts of Maximum Demand, determined to
the nearest kW. The Demand Charge shall include the following billing
components. The Time Related Component shall be for the kilowatts of
Maximum Demand recorded during (or established for) the monthly billing
period. The Facilities Related Component shall be for the kilowatts of Maximum
Demand recorded during (or established for) the monthly billing period.
However, when the Utility determines the Customer's Meter will record little or
no energy use for extended periods of time or when the Customer's Meter has not
recorded a Maximum Demand in the preceding eleven (11) months, the Facilities
Related Component of the Demand Charge may be established at fifty percent
(50%) of the Customer's Connected Load.
4. Maximum Demand
Maximum Demand shall be established for the On-Peak, Mid-Peak, and Off-Peak
periods. The Maximum Demand in any month shall be the measured maximum
average kilowatt input, indicated or recorded by instruments, during any 15-
minute metered interval in the month, but, where applicable, shall not be less than
the diversified resistance welder load computed in accordance with the section
designated Welder Service in Rule 2. Where the demand is intermittent or subject
to violent fluctuations, a 5-minute interval may be used.
5. Power Factor Adjustment
The Customer's bill will be increased each month for power factor by the amount
shown in the Rates section above for service metered and delivered at the
applicable voltage level, based on the per kilovar of maximum reactive demand
imposed by the Utility.
The maximum reactive demand shall be the highest measured maximum average
kilovar demand indicated or recorded by metering during any 15-minute interval
10 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
in the month. The kilovars shall be determined to the nearest unit. A device will
be installed on each kilovar meter to prevent reverse operation of the meter.
6. Temporary Discontinuance of Service
Where the use of energy is seasonal or intermittent, no adjustments will be made
for a temporary discontinuance of service. Any Customer resuming service
within twelve (12) months after such service was discontinued will be required to
pay all charges which would have been billed if service had not been
discontinued.
7. Customer-Owned Electrical Generating Facilities
Upon written approval by the Utility, momentary parallel operation may be
permitted to allow the Customer to test the auxiliary/emergency generating
facilities.
8. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh], demand [kW], kilovar [kVa], etc.).
9. Power Cost Adjustment Factor(PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
10. Change of Law Adjustment Factor(CLAF)
The rates above are subject to an adjustment as provided in Rule 12, Section F.
11. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
11 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
LARGE COMMERCIAL
A. Applicability
Applicable to general services including lighting and power Customers. This Schedule is
applicable to and mandatory for all Customers whose monthly Maximum Demand, in the
opinion of the Utility, is expected to exceed 500 kW or has exceeded 500 kW in any three
(3) months during the preceding twelve (12) months. Any existing Customer on this
- Schedule whose monthly Maximum Demand has registered 500 kW or less for twelve
(12) consecutive months is ineligible for service under this Schedule and shall be
transferred to another applicable Rate Schedule. Service under this Schedule is subject to
Meter availability.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh/Meter/Month
Summer Season—On-Peak 0420950.12736
Mid-Peak 0.076260.08030
Off-Peak 0.048350.05095
Winter Season—-Mid-Peak 0.067210.07081
Off-Peak 000.04749
Customer Charge - $/Meter/Month 515.00
Demand Charge - $/kW of Billing Demand/Meter/Month
Facilities Related 15.00
Time Related Summer—On-Peak 17.00
Summer—Mid-Peak 5.00
Power Factor Adjustment- $/KVA 0.27
D. Special Conditions
1. Time periods are defined as follows:
On-Peak: Noon to 6:00 p.m. summer weekdays except holidays.
Mid-Peak: 8:00 a.m. to noon and 6:00 p.m. to 11:00 p.m. summer weekdays
except holidays.
8:00 a.m. to 9:00 p.m. winter weekdays except holidays.
Off-Peak: All other hours.
Holidays are New Year's Day (January 1), Washington's Birthday (third Monday
in February), Memorial Day (last Monday in May), Independence Day (July 4),
Labor Day (first Monday in September), Veteran's Day (November 11),
12 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
Thanksgiving Day (fourth Thursday in November), and Christmas (December
25).
When any holiday listed above falls on Sunday, the following Monday will be
recognized as an off-peak period. No change will be made for holidays falling on
Saturday.
The Summer Season shall commence at 12:00 a.m. on June 1st and continue until
12:00 a.m. on October 1st of each year. The Winter Season shall commence at
12:00 a.m. on October 1st of each year and continue until 12:00 a.m. on June 1st of
the following year. A pro rata computation will be made for seasonal billing
purposes.
2. Voltage
Service will be supplied at one standard voltage.
3. Maximum Demand
Maximum Demands shall be established for the On-Peak, Mid-Peak, and Off-
Peak periods. The Maximum Demand for each period shall be the measured
maximum average kilowatt input indicated or recorded by instruments, during any
15-minute metered interval, but, where applicable, not less than the diversified
resistance welder load computed in accordance with the section designated
Welder Service in Rule 2. Where the demand is intermittent or subject to violent
fluctuations, a 5-minute interval may be used.
4. Billing Demand
The Billing Demand shall be the kilowatts of Maximum Demand, determined to
the nearest kW. The Demand Charge shall include the following billing
components. The Time Related Component shall be for the kilowatts of
Maximum Demand recorded during (or established for) the monthly billing period
for each of the On-Peak, Mid-Peak, and Off-Peak Time Periods. The Facilities
Related Component shall be for the kilowatts of Maximum Demand recorded
during (or established for) the monthly billing period. However, when the Utility
determines the Customer's Meter will record little or no energy use for extended
periods of time or when the Customer's Meter has not recorded a Maximum
Demand in the preceding eleven(11) months, the Facilities Related Component of
the Demand Charge may be established at fifty percent (50%) of the Customer's
Connected Load. Separate Demand Charge(s) for the On-Peak, Mid-Peak, and
Off-Peak Time Periods shall be established for each monthly billing period. The
Demand Charge for each time period shall be based on the Maximum Demand for
that time period occurring during the respective monthly billing period.
5. Power Factor Adjustment
The Customer's bill will be increased each month for power factor by the amount
shown in the Rates section above for service metered and delivered at the
applicable voltage level, based on the per kilovar of maximum reactive demand
imposed by the Utility.
The maximum reactive demand shall be the highest measured maximum average
kilovar demand indicated or recorded by metering during any 15-minute metered
13 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
interval in the month. The kilovars shall be determined to the nearest unit. A
device will be installed on each kilovar Meter to prevent reverse operation of the
Meter.
6. Temporary Discontinuance of Service
Where the use of energy is seasonal or intermittent, no adjustments will be made
for a temporary discontinuance of service. Any Customer, prior to resuming
service within twelve (12) months after such service was discontinued, will be
required to pay all charges which would have been billed if service had not been
discontinued.
7. Customer-Owned Electrical Generating Facilities
Upon written approval by the Utility, momentary parallel operation may be
permitted to allow the Customer to test the auxiliary/emergency generating
facilities.
8. Contracts
An initial three-year facilities contract may be required where Applicant requires
new or added serving capacity exceeding 2,000 kVA.
9. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh], demand [kW], kilovar [kVa], etc.).
10. Power Cost Adjustment Factor (PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
11. Change of Law Adjustment Factor(CLAF)
The rates above are subject to an adjustment as provided in Rule 12, Section F.
12. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
14 Proposed Effective Date:July 1,2022
.CITY OF RANCHO CUCAMONGA.MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
LARGE INDUSTRIAL
A. Applicability
Applicable to general services including lighting and power Customers delivered at the
utility's primary distribution voltage level of 12 kV. This Schedule is applicable to and
mandatory for all Customers whose monthly Maximum Demand, in the opinion of the
Utility, is expected to exceed 500 kW or has exceeded 500 kW in any three (3) months
during the preceding twelve (12) months. Any existing Customer on this Schedule whose
monthly Maximum Demand has registered 500 kW or less for twelve (12) consecutive
months is ineligible for service under this Schedule and shall be transferred to another
applicable Rate Schedule. Service under this Schedule is subject to Meter availability.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh/Meter/Month
Summer Season—On-Peak 0.09'1580.10370
Mid-Peak 060.08099
Off-Peak 0'019'110.05418
Winter Season—Mid-Peak 0.068780.07542
Off-Peak 0.045480.04987
Customer Charge - $/Meter/Month 400.00515.00
Demand Charge - $/kW of Billing Demand/Meter/Month
Facilities Related 13.50
Time Related Summer—On-Peak 20.00
Summer—Mid-Peak 5.00
Power Factor Adjustment- $/KVA 0.27
D. Special'Conditions
1. Time periods are defined as follows:
On-Peak: Noon to 6:00 p.m. summer weekdays except holidays.
Mid-Peak: 8:00 a.m. to noon and 6:00 p.m. to 11:00 p.m. summer weekdays
except holidays.
8:00 a.m. to 9:00 p.m. winter weekdays except holidays.
Off-Peak: All other hours.
Holidays are New Year's Day (January 1), Washington's.Birthday (third Monday
in February), Memorial Day (last Monday in May), Independence Day (July 4),
Labor Day (first Monday in September), Veteran's Day (November 11),
Thanksgiving Day (fourth Thursday in November), and Christmas (December
25).
15 Proposed Effective Date:July 1,2022
. CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
When any holiday listed above falls on Sunday, the following Monday will be
recognized as an off-peak period. No change will be made for holidays falling on
Saturday.
The Summer Season shall commence at 12:00 a.m. on June 1st and continue until
12:00 a.m. on October 1st of each year. The Winter Season shall commence at
12:00 a.m. on October 1st of each year and continue until 12:00 a.m. on June 1st of
the following year. A pro rata computation will be made for seasonal billing
purposes.
2. Voltage
Service will be supplied at one standard voltage.
3. Maximum Demand
Maximum Demands shall be established for the On-Peak, Mid-Peak, and Off-
Peak periods. The Maximum Demand for each period shall be the measured
maximum average kilowatt input indicated or recorded by instruments, during any
15-minute metered interval, but, where applicable, not less than the diversified
resistance welder load computed in accordance with the section designated
Welder Service in Rule 2. Where the demand is intermittent or subject to violent
fluctuations, a 5-minute interval may be used.
4. Billing Demand
The Billing Demand shall be the kilowatts of Maximum Demand, determined to
the nearest kW. The Demand Charge shall include the following billing
components. The Time Related Component shall be for the kilowatts of
Maximum Demand recorded during (or established for) the monthly billing period
for each of the On-Peak, Mid-Peak, and Off-Peak Time Periods. The Facilities
Related Component shall be for the kilowatts of Maximum Demand recorded
during (or established for) the monthly billing period. However, when the Utility
determines the Customer's Meter will record little or no energy use for extended
periods of time or when the Customer's Meter has not recorded a Maximum
Demand in the preceding eleven(11) months, the Facilities Related Component of
the Demand Charge may be established at fifty percent (50%) of the Customer's
Connected Load. Separate Demand Charge(s) for the On-Peak, Mid-Peak, and
Off-Peak Time Periods shall be established for each monthly billing period. The
Demand Charge for each time period shall be based on the Maximum Demand for
that time period occurring during the respective monthly billing period.
5. Power Factor Adjustment
The Customer's bill will be increased each month for power factor by the amount
shown in the Rates section above for service metered and delivered at the
applicable voltage level, based on the per kilovar of maximum reactive demand
imposed by the Utility.
The maximum reactive demand shall be the highest measured maximum average
kilovar demand indicated or recorded by metering during any 15-minute metered
interval in the month. The kilovars shall be determined to the nearest unit. A
16 Proposed Effective Date:July 1,2022
.CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
device will be installed on each kilovar Meter to prevent reverse operation of the
Meter.
6. Temporary Discontinuance of Service
Where the use of energy is seasonal or intermittent, no adjustments will be made
for a temporary discontinuance of service. Any Customer, prior to resuming
service within twelve (12) months after such service was discontinued, will be
required to pay all charges which would have been billed if service had not been
discontinued.
7. Customer-Owned Electrical Generating Facilities
Upon written approval by the Utility, momentary parallel operation may be
permitted to allow the Customer to test the auxiliary/emergency generating
facilities.
8. Customer Responsibilities
The customer will be responsible for all costs associated with the primary point-
of-delivery installation, including the metering and primary voltage physical
disconnect necessary to isolate the customer's facilities from the utility's facilities.
The customer will be responsible to own, operate and maintain all electrical
distribution facilities on the customer side of the primary point-of-delivery
(typically established at the primary meter).
9. Contracts
An initial three-year facilities contract may be required where Applicant requires
new or added serving capacity exceeding 2,000 kVA.
10. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh], demand [kW], kilovar [kVa], etc.).
11. Power Cost Adjustment Factor(PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
12. Change of Law Adjustment Factor(CLAF)
The rates above are subject to an adjustment as provided in Rule 12, Section F.
13. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers
17 Proposed Effective Date:July 1,2022
.CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS -
STREET LIGHTING
A. Applicability
Applicable to meter for the lighting of streets, and publicly-owned and publicly-operated
automobile parking lots which are opened to the general public where the City owns and
maintains the street lighting equipment and associated facilities included under this Schedule.
B. Territory
Within the entire territory served.
C. Rates
Light Emitting Diode (LED) Lamps—All Night Service
Street Lighting
Energy Charge - $/kWh/Lamp 0.059150.06699
Lamp Charge - $/Lamp/Month 2.50
Safety
Energy Charge - $/kWh/Lamp 0.059150.06699
D. Special Conditions
1. The Applicant shall install streetlights that will be served by the Utility. These
streetlights must be installed in accordance with the Utility's specifications and
the developer will deed such facilities to the City.
2. Requirements and Restrictions
a. The Applicant for street light service shall specify the type of service,
lamp size, and location of street lights.
b. Service shall not be furnished under this Schedule where location,
mounting height, and/or other considerations are unacceptable to the
Utility.
c. The installation of street lighting equipment and facilities hereunder is
contingent upon the utility obtaining easements, and rights of way, as may
be required, satisfactory to the Utility for the required poles, lines,
equipment, and facilities.
d. Should the Applicant not commence using the street lighting in a bona fide
manner within ninety (90) days after date of completion and installation of
a street light or street lighting system requested by the Applicant, the
Utility will bill, and the Applicant shall pay, the applicable lamp
charges(s).
3. Hours of Service
18 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
Under the Utility's standard all night operating schedule, approximately 4,140
hours of service per year will be furnished.
Kilowatt hours for Lamp Type and Size: The kilowatt hours for lamp types and
sizes served under this Schedule used to determine the Energy Charge are shown
below:
Lamp Watts
Including
Lamp Watts Driver Loss kWh per Lamp per
Light Emitting Diode Including Mid-Point Month
(LED)Lamps Driver Loss Range All Night Service
0-5 2.50 0.9
5.01-10 7.50 2.6
10.01-15 12.50 4.3
15.01-20 17.50 6.0
20.01-25 22.50 7.8
25.01-30 27.50 9.5
30.01-35 32.50 11.2
35.01-40 37.50 12.9
40.01-45 42.50 14.7
45.01-50 47.50 16.4
50.01-55 52.50 18.1
55.01-60 57.50 19.8
60.01-65 62.50 21.6
65.01-70 67.50 23.3
70.01-75 72.50 25.0
75.01-80 77.50 26.7
80.01-85 82.50 28.5
85.01-90 87.50 30.2
90.01-95 92.50 31.9
95:01-100 97.50 33.6
100.01-105 102.50 35.4
105.01-110 107.50 37.1
110.01-115 112.50 38.8
115.01-120 117.50 40.5
120.01-125 122.50 42.3
125.01-130 127.50 44.0
130.01-135 132.50 45.7
135.01-140 137.50 47.4
140.01-145 142.50 49.2
145.01-150 147.50 50.9
150.01-155 152.50 52.6
155.01-160 157.50 54.3
160.01-165 162.50 56.1
165.01-170 167.50 57.8
170.01-175 172.50 59.5
19 Proposed Effective Date:July 1,2022
.CITY OF RANCHO CUCAMONGAMUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
4. Maintenance
The Utility shall exercise reasonable care and diligence in maintaining its street
light facilities or Utility-owned attachments thereto. Where the Utility
experiences, or expects to experience, maintenance costs exceeding its normal
maintenance expense resulting from, but not limited to, vandalism, the Utility
may require the customer to pay the excess maintenance expense.
5. Liability of the Utility
The Utility shall not, by taking action pursuant to its tariffs, be liable for any loss,
damage, or injury, established or alleged, which may result, or be claimed to
result, therefrom.
6. Removal, Relocation or Modification of Facilities
Where street lighting service and facilities are ordered removed by a customer,
the customer shall pay to the Utility a nonrefundable amount equal to the total
estimated cost installed less any Customer contribution, plus the estimated cost of
removal less the estimated net salvage value of the facilities.
Where street lighting service and facilities were ordered removed by a Customer
and such service and facilities, or their equivalent are ordered reinstalled within
thirty-six (36) months from the date of the order to remove, the Customer shall
pay to the Utility in advance of reinstallation a nonrefundable amount equal to the
cost of removal of the prior facilities and the estimated cost of such reinstallation.
Where street lighting facilities are ordered modified and /or relocated by a
Customer, the Customer shall pay to the Utility, in advance of such modification
and/or relocation, a nonrefundable amount equal to the estimated cost of such
modification and/or relocation. This includes facilities that now serve street light
load only, but that may have been installed originally to serve other than street
light load.
Utility-owned facilities removed or installed remain the sole property of the
Utility.
7. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above.
8. Power Cost Adjustment Factor(PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
9. Change of Law Adjustment Factor(CLAF)
The rates above are subject to an adjustment as provided in Rule 12, Section F.
10. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
20 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
TRAFFIC CONTROL
A. Applicability
Applicable to single and three-phase service for traffic directional signs or traffic signal
systems located on streets, highways and other public thoroughfares and to railway
crossing and track signals; for public thoroughfare lighting that is utilized twenty-four
(24) hours per day or is not controlled by switching equipment, such as tunnel or
underpass lighting; and, to public authorities for the illumination of bus stop shelters
located in the dedicated road right-of-way where such service is combined with other
traffic control service as defined above.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh 0.105850.11298
Customer Charge- $/Day. 0.60
D. Special Conditions
1. Voltage
Service will be supplied at one (1) standard voltage not in excess of 240 volts or,
at the option of the Utility, at 240/480 volts, three wire, single-phase.
2. Billing Calculation
A Customer's bill is calculated according to the rate and conditions above.
3. Power Cost Adjustment Factor (PCAF)
The rate above is subject to an adjustment as provided in Rule 12, Section E.
4. Change of Law Adjustment Factor(CLAF)
The rate above is subject to an adjustment as provided in Rule 12, Section F.
5. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail.revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
21 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
OUTDOOR AREA LIGHTING
A. Applicability
Applicable to single-phase service for metered outdoor area lighting load, controlled for
dusk to dawn operation and used for purposes other than street and highway lighting such
as, but not limited to parking lots, pedestrian walkways, billboards, building exteriors,
security, sports and recreation areas, monuments, decorative areas, and bus shelters.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh/Meter/Month 0:0604 40.06429
Customer Charge- $/Meter/Month 15.25
D. Special Conditions
1. Voltage
Service will be provided at one (1) standard voltage.
2. Three-Phase Service
Where, in the sole opinion of the Utility, it is impractical to provide single-phase
service under this Schedule, three-phase service will be provided.
3. Separate Point of Delivery
When requested by the Applicant or Customer, and agreed upon by the Utility, an
additional Point of Delivery may be provided, separate from any other Point of
Delivery provided under any other applicable Rate Schedule. Customers so
served shall not be permitted to have an electrical interconnection beyond the
Utility's Point of Delivery between the separately metered loads except upon
written approval of the Utility.
A change from this Schedule to any other Rate Schedule will be permitted if the
additional Point of Delivery is removed. Any such removal shall be at the
Customer's expense:
Any rearrangement of facilities required to provide the additional Point of
Delivery shall be at the expense of the requesting Applicant or Customer.
4. Controlled Operation
Service under this Schedule requires the control of lamps in a manner acceptable
to the Utility so that lamps will not be lighted daily from dawn to dusk. Customer
shall install, own, operate, and maintain the control device: The Utility shall have
22 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
the right to periodically inspect the control device to ensure its correct operation
and maintenance.
5. Distribution Line Extension
Distribution Line Extensions to reach an outdoor area light or area lighting system
shall be in accordance with Rule 15.
6. Services
Services shall be installed and maintained as provided in Rule 16.
7. Incidental Loads
Incidental, non-lighting loads may be served under this Schedule only where such
Connected Loads do not exceed fifteen percent (15) of the Customer's total
Connected Load. Incidental Loads must also be controlled for dusk to dawn
operation exclusively.
8. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh], demand [kW], etc.).
9. Power Cost Adjustment Factor(PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
10. Change of Law Adjustment Factor(CLAF)
The rates above are subject to an adjustment as provided in Rule 12, Section F.
11. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
23 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
IRRIGATION SYSTEMS
A. Applicability
Applicable where the Utility determines that 100% of the customer's electrical usage is
for limited irrigation service except for the Customer whose monthly Maximum Demand,
in the opinion of the Utility, is expected to exceed 20 kW or has exceeded 20 kW in any
three (3) months during the preceding twelve (12) months is ineligible for service under
this Schedule. Effective with the date of ineligibility of any Customer served under this
Schedule, the Customer's account shall be transferred to another applicable Rate
Schedule.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh 0.18459
Customer Charge - $/Day 03000.75700
D. Special Condition
1. Voltage
Service will be supplied at one (1) standard voltage not in excess of 240 volts or,
at the option of the Utility, at 240/480 volts, three wire, single-phase.
2. Billing Calculation
A Customer's bill is calculated according to the rate and conditions above.
3. Power Cost Adjustment Factor(PCAF)
The rate above is subject to an adjustment as provided in Rule 12, Section E.
4. Change of Law Adjustment Factor(CLAF)
The rate above is subject to an adjustment as provided in Rule 12, Section F.
5. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
24 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
WIRELESS TECHNOLOGY
A. Applicability
Applicable to single-phase service for wireless technology industries that require electric
service to operate radio repeaters or similar devices (wireless communication devices)
that are mounted on existing City facilities, or other facilities approved by the Utility and
are unmetered. This Schedule excludes Wi-Fi devices on "looped" (served by 120/240
volts) streetlight facilities. Customers must execute an application/contract with the
Utility for service under this Schedule and must execute an applicable agreement when
devices are attached to City facilities. The monthly kilowatt-hour (kWh) usage of each
device shall not exceed 500 kWh. Effective with the date of ineligibility of any Customer
served under this Schedule, the Customer's account shall be transferred to another
applicable Rate Schedule. If the Customer's account cannot be transferred to another
applicable Rate Schedule, the account will be closed, the Utility's service will be
removed, and the Customer must remove its device and equipment form the applicable
City facility.
B. Territory
Within the entire territory served
C. Rates
Fixed Energy Charge - $/Device/Month 60,3-061.20
Customer Charge- $/Month 17.29
Inspection Charge - $/Device/Month 12.60
Three-Phase Service - $/Day 0.03
Initialization of Service Charge 6.79
D. Special Conditions
1. Contract
An approved City contract is required for service under this Rate Schedule.
2. Voltage
Service will be supplied at one (1) standard voltage not in excess of 240 volts.
3. Three-Phase Service
Where the Utility provides three-phase service, the billing will be increased by the
amount shown in the Rates section above.
4. Maximum Wattage
The maximum watts/connected load/name plate is 746 watts.
5. Installation
The device(s) shall be installed on City facilities or other facilities approved by
the Utility. When the devices are installed on City facilities, the installation and
25 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
removal of such device(s) will be performed by the Customer, and at the
Customer's expense. Device installation shall not be performed under this Rate
Schedule, where location, mounting height, and/or other considerations are not
acceptable to the Utility. Unless approved by the Utility, all wireless
communication devices must be visible to the Utility.
7. Modification of Facilities
No modifications can be made to the Customer-owned wireless communications
devices unless approved by the Utility. Where the Customer requests a
modification of City facilities, and such modifications are acceptable to the City,
the City will perform the requested modifications at the Customer's expense.
8. Maintenance
The Utility shall exercise reasonable care and diligence in maintaining its
facilities. Upon installation of the device(s), where the Utility experiences, or
expects to experience, maintenance costs exceeding its normal maintenance
expense resulting from, but not limited to, vandalism, the Utility may require the
Customer to pay the excess maintenance expense.
9. Liability of the Utility
The Utility shall not, by taking action pursuant to its tariffs, be liable for any loss,
damage, or injury, established or alleged, which may result, or be claimed to
result, there from.
10. Initialization of Service Charge
A one-time charge, as shown in the Rates section of this Rate Schedule, is applied
to each service account provided service under this Rate Schedule to recover the
costs of a lock and spare fuse which are required with the initialization of service.
11. Power Cost Adjustment Factor(PCAF)
The rates above are subject to an adjustment as provided in Rule 12, Section E.
12. Change of Law,Adjustment Factor(CLAF)
The rates above are subject to an adjustment as provided in Rule 12, Section F.
13. State Mandated Public Purpose Programs Charge
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
26 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
NET ENERGY METERING
A. Applicability
Applicable to a customer who operates a renewable electrical generation facility that is
located on the customer's premises with a capacity of not more than 1 MW that is
interconnected and operates in parallel with the City's electric system, intended primarily
to offset part or all of the customer's own electrical requirements, and meets all the
applicable safety and performance standards.
B. Territory
Within the entire territory served.
C. Net Surplus Compensation Rate
For customer accounts established on or after December 1, 2018: The net surplus
compensation rate shall be $0.0500 per kWh applied to any net surplus energy remaining
at the end of the customer's twelve (12) monthly billing period ("relevant period").
Grandfathered Provision: For customer accounts established before December 1, 2018:
The net surplus' compensation rate shall be equivalent to the highest hourly rate that was
charged for consumption in their OAT during the year prior to the Customer's Annual
Billing Date. This provision will remain in effect for fifteen (15) years from the
Customer's original year in which the generating facility was interconnected to RCMU's
grid. After that period expires, the Customer will receive the current net surplus
compensation that is being offered at that time.
D. Rates
1. All rates charged under this schedule will be in accordance with the Eligible
Customer-Generator's otherwise applicable tariff (OAT) or rate schedule. An
Eligible Customer-Generator served under this schedule is responsible for all
charges in its OAT including the monthly or annual minimum charges (including
service, customer, reliability and demand charges, when applicable) regardless of
the Customer's monthly or annual net generation.
Eligible Customers under this schedule are subject to any new or additional
charge(s) that may be imposed by the Utility on the other customer in the rate
class to which Customer would otherwise be assigned.
2. As determined in each billing period, when a customer consumes more energy
than generated at the premises (net consumer), the net consumed energy will be
used in the calculation of all applicable energy charges, calculated by multiplying
the net amount consumed by the applicable energy rate components of the
customer's OAT. •
27 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
3. As determined in each billing period, when a customer generates more energy
than is consumed by the customer (net generator), the resulting net produced
energy will be calculated by multiplying the net produced kWh by the applicable
energy rate component of the Customer's OAT (including TOU periods) and be a
credit on the bill. Any net kilowatt-hours of production credit that exceeds the net
consumed energy,will be carried forward into the next billing period.
If the Customer's OAT includes "time of use" (TOU) rates, any net energy
consumed monthly shall be calculated according to the terms of the OAT. When
the customer is a net generator during any TOU period, the net kilowatt-hours
generated shall be valued at the same price per kilowatt-hour as the Utility would
charge during that same TOU period.
4. Customers who are Net Surplus Electricity producers at the Customer's Annual
True-Up Date, may elect to either carry over annual Net Surplus Energy
production (in kilowatt hours) as a credit that will be applied to kilowatt hours
consumed by the Customer or Customer may elect to receive payment to cash out
the remaining Net Surplus Energy.
D. Special Condition
1. An executed Net Energy Metering and Generating Facility Interconnection
Agreement is required prior to receiving service under this Schedule.
2. Metering Requirements: If the customer's existing meter is not capable of
measuring the flow of energy in two directions, an appropriate meter shall be
provided at the expense of the customer. The City may elect to install an
additional meter or meters, at the City's expense to provide the information
necessary to accurately bill or credit the customer.
3. To be eligible for service under this Schedule, the customer's generating facilities
must be sized to offset part or all of the customer's own electrical requirements
and cannot be oversized. This means that the estimated output of the generating
facility, using the CEC-AC nameplate rating for inverter-based generating
facilities must not exceed the customer's previous annual usage in kWh.
4. A new customer of record who owns, leases, or rents a premise that includes an
existing generating facility with a capacity under 30 kW that was approved by
RCMU for operation prior to the new customer moving in and/or taking electric
service with RCMU will take service under this Tariff as long as the requirements
of this Tariff are met and will not have to sign a new Interconnection Agreement.
This provision also applies to premises where the developer/contractor establishes
the interconnection.
A new customer of record who owns, leases, or rents a premise that includes an
existing generating facility with a capacity over 30 kW that was approved by
RCMU for operation prior to the new customer moving in and/or taking electric
service with RCMU will take service under this Tariff and will need to sign a new
Interconnection Agreement.
28 Proposed Effective Date:July I,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
5. RCMU shall retain any net surplus energy generated by the NEM Customer
including any associated environmental attributes or renewable energy credits
(RECs).
6. Net Metering Aggregation (NMA): Customers served under this Tariff with a
Generating Facility on a property owned by the Customer, may elect to aggregate
electric services to additional properties that are solely owned by the Customer
and are located on parcels adjacent or contiguous to the Generating Facility.
Generation not used where the Generating Facility is located, is transferred to
adjacent properties and equally distributed to the other properties by a percentage
determined upon entering into the Interconnection Agreement. NMA does not
allow for Net Surplus Compensation for excess generation.
E. Billing
1. City shall provide all customers served under this Schedule with net energy
consumption information and/or net energy export information with each monthly
bill.
2. Customers served under this Schedule shall pay both energy and non-energy
charges on a monthly basis, in accordance with the customer's OAT except as
otherwise allowed by State law. The value of net energy production will be used
to offset only energy related charges in subsequent billing periods.
F. Definitions
1. Net energy metering measures the difference between the electricity supplied
through the electric grid and the electricity generated on the customer's premises
and fed back to the electric grid over a Twelve-Month Period.
2. Otherwise Applicable Tariff(OAT) is the customer's regularly filed rate schedule
under which service is rendered.
3. Net Surplus Electricity is the electricity generated by an eligible customer-
generator measured in kilowatt hours over a 12-month period that exceeds the
amount of electricity consumed by that eligible customer-generator.
29 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
ECONOMIC DEVELOPMENT
A. Applicability
Commercial or industrial end-use Customers that would otherwise receive service under
the Large Commercial or Large Industrial Electric Rate Schedule and meet certain
criteria as established and adopted by resolution of the City Council of the City of
Rancho Cucamonga may take advantage of the Economic Development (ED) rate as a
New Customer or Expanded Load Customer. This ED rate is applicable to all or part of
the services provided to New Customers and Expanded Load Customers, as such terms
are defined herein.
1. A New Customer shall be a Customer seeking to locate a new business or relocate
an existing business (not currently located within the territory served by the
Rancho Cucamonga Municipal Utility (RCMU)) within RCMU's service
territory.
a. A New Customer shall meet both of the following criteria in order to
qualify for Schedule ED:
i. Projected minimum monthly electric demand of at least 200 kW.
ii. Job Creation
1. Tier 1 Discount Rate 100—249 jobs
2. Tier 2 Discount Rate 250—500 jobs
3. Tier 3 Discount Rate greater than 500 jobs
2. An Expanded Load Customer shall be an existing RCMU Large Commercial or
Large Industrial customer that is adding new load to RCMU by a minimum
monthly electric demand of 200 kW based upon the Customer's past electrical
demand as determined by RCMU. The expanded load can be at the customer's
current site, or at a new site within the RCMU service territory. The Tier 1 ED
rate will only be applied to the expanded load as determined in Section 6 below.
B. Territory
Within the entire territory served.
C. Character of Service
The service provided hereunder shall be alternating current with regulated frequency of
60 hertz, three-phase, or a combination single and three-phase served through one meter,
at a standard voltage specified by RCMU. To be eligible to participate all customers must
have a demand meter.
D. Rates
Except as provided herein, or in the Economic Development Rate Agreement, all charges
and provisions of the Customer's otherwise applicable rate schedule shall apply. The
applicable Energy Charge and Demand Charge under the Customer's otherwise
applicable rate schedule will be reduced as follows:
30 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
Tier 1 Tier}2 Tier 3
Years 1 -2 20% 20% 20%
Years 3 -4 15% 17% 20%
Year 5 10% 12% 15%
E. Special Conditions
1. Term: Economic Development Rate Agreements entered into under this Schedule
shall be for a single five-year term.
2. Approval: Application of this Rate Schedule shall be subject to the approval of
the City Manager or his/her designee, based on meeting the eligibility criteria
outlined herein.
3. Agreement: The Customer must sign a standard Rancho Cucamonga Economic
Development Rate Agreement in order for the rates under this Schedule to be
applicable. In addition to the other terms of this Schedule, the Economic
Development Rate Agreement shall require the Customer to reimburse Rancho
Cucamonga for all rate reductions received under this Schedule, if the Customer
fails to maintain the required minimum load during the five-year term of the
Agreement.
4. Minimum Load: Customers qualifying under this Schedule as a New Customer
with a projected minimum monthly electric demand of at least 200 kW or as an
Expanded Load Customer under Applicability Sections 1 and 2 above,
respectively, must agree to maintain a minimum level of load for five years from
the date service is first rendered under this Schedule and to document compliance
with all applicable requirements, as set forth in the Economic Development Rate
Agreement.
5. Job Creation / Retention: Customers qualifying under this Schedule as a New
Customer with a projected minimum monthly electric demand of at least 200 kW
under Applicability Section la (ii), respectively, must agree to create and retain a
minimum level of full-time equivalent jobs for five years from the date service is
first rendered under this Schedule and to document compliance with all applicable
requirements, as set forth in the Economic Development Rate Agreement.
6. Base Period Usage: Base Period Usage shall be established and agreed to in the
Economic Development Rate Agreement for Expanded Load Customers. Base
Period Usage shall be the average monthly energy use and demand for the
Customer during the last three years of service to the Customer, from the date
ending the last payment period before the date of the Agreement. Expanded Load
qualifying for the rate under this Schedule shall be measured as the difference
between the new monthly, metered documented energy use and demand, and the
Base Period Usage.
7. State Mandated Public Purpose Program Charge: All bills rendered under this
Schedule shall be subject to the Public Purpose Program Charge as established by
the City Council.
31 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
8. Miscellaneous Fees and Charges: Rates charged pursuant to this Schedule shall be
subject to any Energy Users Taxes, Utility Users Taxes, and any other
governmental taxes, duties, or fees which are applicable to Electric Service
provided to Customer by the City of Rancho Cucamonga. Rates are also subject to
adjustment, as established by the City of Rancho Cucamonga's City Council, in
its sole discretion, in response to federal or state climate change laws, renewable
portfolio standard or other mandated legislation. These adjustments may include
but are not limited to charges to mitigate the impacts of greenhouse gas emissions
or"green power"premiums.
9. Expanded Load: Expanded Load customers applying for this rate must
demonstrate to the satisfaction of the Utility that the expanded load is new to the
Rancho Cucamonga Municipal Utility.
10. Effective Date: The effective date of the Economic Development Rate Agreement
shall commence within 12 months from the date of the City's approval, or the
Agreement becomes null and void. The Agreement becomes effective upon
execution by the parties, and the Economic Development Rate commences upon
written notice by Customer and coincides with the Customer's normal billing
cycle.
11. Reapplication: Customers who have received service under the Economic
Development Rate are eligible to reapply for the rate as an Expanded Load
Customer, if they meet the criteria therefore.
12. Restrictions: Residential customers and federal, state or local government
agencies are not eligible to apply for service under this Schedule.
32 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
STANDBY DEMAND CAPACITY RESERVATION CHARGE
(SELF GENERATION)
A. Applicability
Applicable to Large Commercial and Large Industrial customers who operates a non-net
metered, non-utility generating facility rated at 1000 kW or less, interconnected on the
Customer'.s premises and operates in parallel with the City's electric system. The
generating facility is intended primarily to offset part or all of the customer's own
electrical requirements and meets all the applicable safety and performance standards.
Standby service customers have unique electric demands, due to their on-site generation
assets, that are often quite different from those of full requirement customers. These
customers pay standby rates so that they may, in the event of a planned or unplanned
outage of their non-utility generating system, take service from the City electric system.
The City bears an "obligation to serve" and must configure their system to allow every
customer reliable access to the grid. The standby charge is designed to recover the costs
of transmission and distribution facilities, as well as substation and transformers
dedicated to the customer's use that do not vary with usage in maintaining sufficient
capacity (through operating reserves) in order to serve an unplanned outage, even if such
an outage never occurs. The standby charge also includes appropriate service voltage
level distinctions: secondary and primary.
B. Territory
The entire territory served.
C. Rates
1. Rates for this service shall be the same as for the schedule under .which the
customer's otherwise applicable rate schedule shall apply.
2. Standby Demand Capacity Reservation Charge (CRC): A CRC shall be a flat
$/kW amount applied to the Standby Demand in kW, which represents the entire
reserved capacity needed for the City to serve the self-generation customer's load,
which would have been regularly served by the customer's generating facility
when such facility experiences a partial or complete outage. The level of Standby
Demand shall be provided by the customer and shall not exceed the nameplate
capacity of the customer's generating facility.
Standby Charge—Secondary ($/kW) Standby Charge—Primary ($/kW)
$8.61 $7.61
3. Demand Charge: As determined in each billing period, a Standby Service
customer's billing demand shall be the kilowatts of Maximum Demand indicated
or recorded by instruments, determined to the nearest kW of the absolute net
power that the customer received from the City's electric system. The Demand
33 Proposed Effective Date:July I,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
Charge for each time period shall be based on the Maximum Demand for that
time period occurring during the respective monthly billing period.
4. Energy Charge: As determined in each billing period, when a Standby Service
customer consumes more energy than generated at the premises, the net consumed
energy will be used in the calculation of all applicable energy charges. All Energy
shall be billed in accordance with the customer's Otherwise Applicable Tariff rate
schedule which would otherwise apply if the customer had no generating
equipment.
5. Other charges: All other specific rate components, including the Power Factor
Adjustment Charge, Customer Charge and the State Electric SurTax will not vary
based on registered usage or demand of the customer's generating facility.
D. Special Conditions
1. Contract Required - Customer shall sign an Interconnection Agreement contract
for this service, which shall state the number of kW of standby capacity required.
"Standby capacity" shall not exceed the nameplate rating of the customer's
generating equipment.
2. Metering Requirements - If the customer's existing meter is not capable of
measuring the flow of energy in two directions, an appropriate meter shall be
provided at the expense of the customer. The City may elect to install an
additional meter or meters, at the customer's expense to provide the information
necessary to accurately bill or credit the customer.
3. The CRC tariff is only applicable to Standby Service customers who require
electric capacity and energy supplied by the City on a regular basis to supplement
the Customer's power requirement in addition to that ordinarily supplied by the
on-site non-utility generation facilities. If a customer has a planned generator
outage with prior notification given to RCMU for an entire billing period the
standby charge will not be applicable.
4. Customers exempted from the CRC tariff:
(a) Customers with backup on-site generation that is used exclusively when service
from the utility is not available in the event of an interruption in utility service and
which are not used to offset Customer electricity purchases.
(b) The applicability of these exemptions shall be determined at the discretion of the
Utilities Manager.
5. Standby Demand in kW represents the entire reserved capacity needed for the
City to serve the customer's load, regularly served by the customer's generating
facility when such facility experiences a partial or complete outage. The level of
Standby Demand, which shall not exceed the nameplate capacity of the
customer's generating facility, is initially designated by the customer and is set
forth in the generation interconnection agreement. Once a customer's designated
34 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
Standby Demand has been set, it shall remain at such level for a minimum of 12
months unless, in the City's determination, the Standby Demand needs to be
adjusted to more accurately represent the customer's actual reserve capacity
needs. Upon the City's determination that the customer's designated Standby
Demand does not reflect the actual level of needed reserve capacity, over any 15-
minute period or through on-site verification, the City shall adjust the Standby
Demand to reflect the actual needed reserve capacity. When the Standby Demand
is adjusted by the City as provided above, a qualified change in the Standby
Demand shall not be made for 12 months from the last adjustment. The customer
is responsible for notifying the City of permanent or material changes in their
generation facilities (size, type and operations) for future adjustments to the
Standby Demand.
6. Diversity Factor - a statistical assumption that a certain percentage of standby
load will be utilizing substation and distribution service between each class' peak
demand and the system peak demand. This factor was determined using the
diversity factors calculated in the utility's most recent cost of service study and is
embedded in the current CRC tariff. A percentage difference was identified as the
diversity factor and the distribution and substation portion of the standby rates
were reduced accordingly reflecting a reduction in those infrastructure
requirements.
E. Billing Calculation
A Customer's bill is calculated according to the rates and conditions above. The charges
are calculated by applying the Rate Charges on the customer's applicable nameplate
generation capacity for the generating unit at the customer's facility. All other usage
provided by RCMU will be based on the applicable rate tariff, including any riders or
additional charges.
Customers served under this Schedule shall pay both energy and non-energy charges on a
monthly basis, in accordance with the customer's Otherwise Applicable Tariff except as
otherwise allowed by State law.
35 Proposed Effective Date:July I,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
ELECTRIC VEHICLE CHARGING
A. Applicability
Applicable solely for the charging of electric vehicles, on a premises or public right of
way where a separate RCMU meter to serve electric vehicle (EV) charging facilities is
requested.
B. Territory
Within the entire territory served.
C. Rates
Energy Charge - $/kWh/Meter/Month
Summer Season—On-Peak 0.229070.23654
Mid-Peak 0.100670.10395
Off-Peak 0.0/1380.04273
Winter Season—On-Peak 0.085090.08786
Mid-Peak 0.076820.07932
Off-Peak 0.048260.04983
Customer Charge - $/Meter/Month Under 20 kW 28.163.0.00
Over 20 kW 4-74-90185.00
Demand Charge - $/kW of Billing Demand/Meter/Month
Facilities Related 12.00
Power Factor Adjustment- $/KVA 0.30
D. Special Conditions
1. Time periods are defined as follows:
On-Peak: Noon to 6:00 p.m. weekdays except holidays
Mid-Peak: 8:00 a.m. to noon and 6:00 p.m. to 11:00 p.m. weekdays except
holidays.
Off-Peak: All other hours.
Holidays are New Year's Day (January 1), Washington's Birthday (third Monday
in February), Memorial Day (last Monday in May), Independence Day (July 4),
Labor Day (first Monday in September), Veteran's Day (November 11),
Thanksgiving Day (fourth Thursday in November), and Christmas (December
25).
When any holiday listed above falls on Sunday, the following Monday will be
recognized as an off-peak period. No change will be made for holidays falling on
Saturday.
The Summer Season shall commence at 12:00 a.m. on June 1st and continue until
12:00 a.m. on October 1st of each year. The Winter Season shall commence. at
36 Proposed Effective Date:July 1,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
12:00 a.m. on October 1st of each year and continue until 12:00 a.m. on June 1st of
the following year. A pro rata computation will be made for seasonal billing
purposes.
2. Voltage Service will be supplied at one (1) standard voltage.
3. Metering
Only EV charging facilities and related equipment shall be separately metered and
served under this Schedule. Where RCMU determines that the operation of the
EV charging facilities may interfere with service to that customer or other
customers, RCMU will install a load management device at customer's expense to
control when EV charging will occur. For purposes of monitoring customer load,
RCMU may install at its expense, load research metering. The customer shall
provide, at no expense to RCMU, a suitable location for meters and associated
equipment.
4. Billing Demand
The Billing Demand shall be the kilowatts (kW) of Maximum Demand,
determined to the nearest kW. The Demand Charge may include the following
billing components. The Time Related Component shall be for the kilowatts of
Maximum Demand recorded during (or established for) the monthly billing
period. The Facilities Related Component shall be for the kilowatts of Maximum
Demand recorded during (or established for) the monthly billing period.
However, when the Utility determines the Customer's Meter will record little or
no energy use for extended periods of time or when the Customer's Meter has not
recorded a Maximum Demand in the preceding eleven (11) months, the Facilities
Related Component of the Demand Charge may be established at fifty percent
(50%) of the Customer's Connected Load.
5. Maximum Demand
The Maximum Demand in any month shall be the measured maximum kilowatt
input, indicated or recorded by instruments, during any 15-minute metered
interval in the month.
6. Power Factor Adjustment
The Customer's bill will be increased each month for power factor by the amount
shown in the Rates section above for service metered and delivered at the
applicable voltage level, based on the per kilovar of maximum reactive demand
imposed by the Utility.
The maximum reactive demand shall be the highest measured maximum average
kilovar demand indicated or recorded by metering during any 15-minute interval
in the month. The kilovars shall be determined to the nearest unit. A device will
be installed on each kilovar meter to prevent reverse operation of the meter.
7. Interconnection
Customers taking service under this Schedule shall have no electrical
interconnection beyond the RCMU's Point of Delivery between electrical loads
eligible for service under this Schedule and any other electrical loads.
8. Temporary Discontinuance of Service.
37 Proposed Effective Date:July I,2022
CITY OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
Where the use of energy is seasonal or intermittent, no adjustments will be made
for a temporary discontinuance of service. Any Customer resuming service
within twelve (12) months after such service was discontinued will be required to
pay all charges which would have been billed if service had not been
discontinued.
9. Customer-Owned Electrical Generating Facilities.
Upon written approval by the Utility, momentary parallel operation may be
permitted to allow the Customer to test the auxiliary/emergency generating
facilities.
10. Billing Calculation.
A Customer's bill is calculated according to the rates and conditions above. The
charges are calculated by applying the Rate Charges when applicable to the actual
billing determinants (kilowatt hours [kWh], demand [kW], kilovar [kVa], etc.).
11. Power Cost Adjustment Factor(PCAF).
The rates above are subject to an adjustment as provided in Rule 12, Section E.
12. Change of Law Adjustment Factor(CLAF).
The rates above are subject to an adjustment as provided in Rule 12, Section F.
12. State Mandated Public Purpose Programs Charge.
State law requires all California electric utilities to establish a public purpose
program charge of 2.85% of electric retail revenues to fund qualifying energy
efficiency programs, renewable energy resources, research and demonstration
projects, and services for low-income electricity customers.
38 Proposed Effective Date:July 1,2022
' CITY.OF RANCHO CUCAMONGA MUNICIPAL UTILITY
ELECTRIC RATES&TARIFFS
SERVICE ESTABLISHMENT CHARGE
A. Applicability
Applicable to General Service and Domestic Service customers.
B. Territory
Within the entire territory served.
C. Rates
For each establishment of electric service $15.00
D. Special Conditions
1. The service establishment charge provided for herein is in addition to the charges
calculated in accordance with the applicable schedule and may be made each time
an account is established. As used herein, establishment means each time an
account is opened, including a turn on of electric service or a change of name
which requires a meter reading.
2. In case the customer requests that electric service be established on the day of his
request or outside of regular hours, an additional charge of$11.00 may be made.
39 Proposed Effective Date:July 1,2022