Loading...
HomeMy WebLinkAbout02-98 - Resolutions RESOLUTION NO. 02-98 A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA, CALIFORNIA,APPROVING TENTATIVE PARCEL MAP SUBTPM15923, A SUBDIVISION OF TWO PARCELS ON 18.54 ACRES OF LAND IN MIXED USE DISTRICT(MHO)OF THE TERRA VISTA COMMUNITY PLAN, LOCATED AT THE SOUTHWEST CORNER OF CHURCH STREET AND MAYTEN AVENUE, AND MAKING FINDINGS IN SUPPORT THEREOF -APN: 227-151-70. A. Recitals. 1. Fountain Glen Properties, filed an application for the approval of Tentative Parcel Map SUBTPM15923, as described in the title of this Resolution. Hereinafter in this Resolution, the subject Tentative Tract Map request is referred to as "the application." 2. On the 23rd day of October 2002, the Planning Commission of the City of Rancho Cucamonga conducted a duly noticed public hearing on the application and concluded said hearing on that date. 3. All legal prerequisites prior to the adoption of this Resolution have occurred. B. Resolution. NOW, THEREFORE, it is hereby found, determined, and resolved bythe Planning Commission of the City of Rancho Cucamonga as follows: 1. This Commission hereby specifically finds that all of the facts set forth in the Recitals, Part A, of this Resolution are true and correct. 2. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing on October 23, 2002, including written and oral staff reports, together with public testimony, this Commission hereby specifically finds as follows: a. The application applies to property located on southwest comer of Church Street and Mayten Avenue, with a street frontage of 1,164.44 feet along Mayten Avenue and 435.96 feet along Church Street, and is presently vacant; and b. The property to the north and west of the subject site contains the Rancho San Antonio Medical Center, the property to the south is developed with retail and restaurant uses, including the Lowe's Home Improvement store, the property to the east is vacant; and C. The application proposes the subdivision of a 18.54 acre site into two parcels of 7.19 acres and 11.35 acres respectively, on which the construction of a senior apartment project has been proposed on the 7.19-acre site under DRC2002-00633, the remainder parcel will be subject to further master plan and development review; and d. The subdivision,together with the recommended conditions of approval, complies with all minimum development standards for the City of Rancho Cucamonga. 3. Based upon the substantial evidence presented to this Commission during the above-referenced public hearing and upon the specific findings of facts set forth in paragraphs 1 and 2 above, this Commission hereby finds and concludes as follows: PLANNING COMMISSION RESOLUTION NO. 02-98 SUBTPM15923— FOUNTAIN GLEN PROPERTIES October 23, 2002 Page 2 a. That the tentative parcel map is consistent with the General Plan, Development Code, and the Terra Vista Community Plan; and b. That the design or improvements of the tentative parcel map is consistent with the General Plan, Development Code, and the Terra Vista Community Plan; and C. That the site is physically suitable for the type of development proposed; and d. That the design of the subdivision is not likely to cause substantial environmental damage and avoidable injury to humans and wildlife or their habitat; and e. That the tentative parcel map is not likely to cause serious public health problems; and f. That the design of the tentative parcel map will not conflict with any easement acquired by the public at large, now of record, for access through or use of the property within the proposed subdivision. 4. Based upon the facts and information contained in the proposed Mitigated Negative Declaration, togetherwith all written and oral reports included for the environmental assessment for the application,the Planning Commission finds that there is no substantial evidence that the project will have a significant effect upon the environment and adopts a Mitigated Negative Declaration and Monitoring Program attached hereto, and incorporated herein by this reference, based upon the findings as follows: a. That the Mitigated Negative Declaration has been prepared in compliance with the California Environmental Quality Act of 1970, as amended, and the State CEQA guidelines promulgated thereunder; that said Mitigated Negative Declaration and the Initial Study prepared therefore reflect the independent judgment of the Planning Commission; and, further, this Commission has reviewed and considered the information contained in said Mitigated Negative Declaration with regard to the application. b. Although the Mitigated Negative Declaration identifies certain significant environmental effects that will result if the project is approved, all significant effects have been reduced to an acceptable level by imposition of mitigation measures on the project,which are listed below as Conditions of Approval. C. Pursuant to the provisions of Section 753.5(c) of Title 14 of the California Code of Regulations, the Planning Commission finds as follows: In considering the record as a whole, the Initial Study and Mitigated Negative Declaration for the project, there is no evidence that the proposed project will have potential for an adverse impact upon wildlife resources orthe habitat upon which wildlife depends. Further, based upon the substantial evidence contained in the Mitigated Negative Declaration, the staff reports and exhibits, and the information provided to the Planning Commission during the public hearing, the Planning Commission hereby rebuts the presumption of adverse effect as set forth in Section 753.5(c-1-d) of Title 14 of the California Code of Regulations. 5. Based upon the findings and conclusions set forth in paragraphs 1, 2, 3, and 4 above, this Commission hereby approves the application subject to each and every condition set forth below and in the Standard Conditions, attached hereto and incorporated herein by this reference: PLANNING COMMISSION RESOLUTION NO. 02-98 SUBTPM15923— FOUNTAIN GLEN PROPERTIES October 23, 2002 Page 3 Planning Division 1) Reciprocal agreements for all parcels ensuring joint use of all drive aisles for emergency access shall be provided by CC&Rs or deeds and shall be recorded prior to, or concurrent with, Final Parcel Map SUBTPM15923 and with Parcel 1 of Parcel Map 11341. Engineering Division 1) Obtain right-of-way dedication and complete Mayten Avenue curb and gutter and streetlights on both sides of the street from Foothill Boulevard to Church Street. Mayten Avenue is a City"Industrial Local' Street. 2) Install or modify traffic signal at Foothill Boulevard and Mayten Avenue. 3) All vehicle access points to public streets shall be drive approach per City Standard Drawing No. 101 Type C. 4) No new drive approach or median opening is allowed on Church Street. 5) Proposed driveway on Mayten Avenue shall align with the future approach on the opposite side of the street. 6) All gated entrances shall conform to City Standard. 7) Sump condition design within the tract requires outlet capacity to handle Q100 and a secondary overflow shall be provided to handle Q100 if the sump is plugged. 8) Provide an illuminated entrance monument sign. 9) Provide 1-foot candle street light illumination of project entrance. 10) Missing improvements along Milliken Avenue, Foothill Boulevard, and Church Street shall be installed to the satisfaction of the City Engineer. Environmental Mitigation Water 1) Prior to issuance of grading permits, the applicant shall prepare a SWPPP that identifies BMPs to be implemented during the period the site is under construction. The City Engineer shall identify bMPs on the Grading Plans for review and approval. Air Quality 1) The site shall be treated with water or other soil-stabilizing agent (approved by SCAQMD and RWQCB) daily to reduce PM10 emissions, in accordance with SCAQMD Rule 403. PLANNING COMMISSION RESOLUTION NO. 02-98 SUBTPM15923 — FOUNTAIN GLEN PROPERTIES October 23, 2002 Page 4 2) Streets adjacent to the site shall be swept according to a schedule established by the City to reduce PM10 emissions associated with vehicle tracking of soil off-site. Timing may vary depending upon time of year of construction. . 3) Grading operations shall be suspended when wind speeds exceed 25 mph to minimize PM10 emissions from the site during such episodes. 4) Chemical soil stabilizers (approved by SCAQMD and RWQCB) shall be applied to all inactive construction areas that remain inactive for 96 hours or more to reduce PM10 emissions. 5) The construction contractor shall select the construction equipment used on-site based on low emission factors and high-energy efficiency. The construction contractor shall ensure the Construction-Grading Plans include a statement that all construction equipment will be tuned and maintained in accordance with the manufacturer's specifications. 6) The construction contractor shall utilize electric or clean alternative fuel powered equipment where feasible. 7) The construction contractor shall ensure that Construction-Grading Plans include a statement that work crews will shut off equipment when not in use. 6. The Secretary to this Commission shall certify to the adoption of this Resolution. APPROVED AND ADOPTED THIS 23RD DAY OF OCTOBER 2002. PLANNING COMMISSION OF THE CITY OF RANCHO CUCAMONGA BY: J // r � t L rry T. cNiel, Chairman ATTEST: Brad Bull ecret I, Brad Buller, Secretary of the Planning Commission of the City of Rancho Cucamonga, do hereby certify that the foregoing Resolution was duly and regularly introduced, passed, and adopted by the Planning Commission of the City of Rancho Cucamonga, at a regular meeting of the Planning Commission held on the 23rd day of October 2002, by the following vote-to-wit: AYES: COMMISSIONERS: MACIAS, MCNIEL, STEWART, TOLSTOY NOES: COMMISSIONERS: NONE ABSENT: COMMISSIONERS: MANNERINO City of Rancho Cucamonga MITIGATION MONITORING PROGRAM Project File No.: Tentative Parcel Map SUBTPM15923 and Development Review DRC2002-00633 This Mitigation Monitoring Program(MMP)has been prepared for use in implementing the mitigation measures identified in the Mitigated Negative Declaration for the above-listed project. This program has been prepared in compliance with State law to ensure that adopted mitigation measures are implemented (Section 21081.6 of the Public Resources Code). Program Components - This MMP contains the following elements: 1. Conditions of approval that act as impact mitigation measures are recorded with the action and the procedure necessary to ensure compliance.The mitigation measure conditions of approval are contained in the adopted Resolution of Approval for the project. 2. A procedure of compliance and verification has been outlined for each action necessary. This procedure designates who will take action, what action will be taken and when, and to whom and when compliance will be reported. 3. The MMP has been designed to provide focused, yet flexible guidelines. As monitoring progresses, changes to compliance procedures may be necessary based upon recommendations by those responsible for the program. Program Management - The MMP will be in place through all phases of the project. The project planner, assigned by the City Planner, shall coordinate enforcement of the MMP. The project planner oversees the MMP and reviews the Reporting Forms to ensure they are filled out correctly and proper action is taken on each mitigation. Each City department shall ensure compliance of the conditions (mitigation) that relate to that department. Procedures -The following steps will be followed by the City of Rancho Cucamonga. 1. A fee covering all costs and expenses, including any consultants' fees, incurred by the City in performing monitoring or reporting programs shall be charged to the applicant. 2. A MMP Reporting Form will be prepared for each potentially significant impact and its corresponding mitigation measure identified in the Mitigation Monitoring Checklist, attached hereto. This procedure designates who will take action,what action will betaken and when,and to whom and when compliance will be reported. All monitoring and reporting documentation will be kept in the project file with the department having the original authority for processing the project. Reports will be available from the City upon request at the following address: City of Rancho Cucamonga - Lead Agency Planning Division 10500 Civic Center Drive Rancho Cucamonga, CA 91730 Mitigation Monitoring Program SUBTPM15923 and DRC2002-00633 Page 2 3. Appropriate specialists will be retained if technical expertise beyond the City staff's is needed,as determined by the project planner or responsible City department,to monitor specific mitigation activities and provide appropriate written approvals to the project planner. 4. The project planner or responsible City department will approve, by signature and'date, the completion of each action item that was identified on the MMP Reporting Form. After each measure is verified for compliance, no further action is required for the specific phase of development. 5. All MMP Reporting Forms for an impact issue requiring no further monitoring will be signed off as completed by the project planner or responsible City department at the bottom of the MMP Reporting Form. 6. Unanticipated circumstances may arise requiring the refinement or addition of mitigation measures.The project planner is responsible for approving any such refinements or additions. An MMP Reporting Form will be completed bythe project planner or responsible City department and a copy provided to the appropriate design, construction, or operational personnel. 7. The project planner or responsible City department has the authority to stop the work of construction contractors if compliance with any aspects of the MMP is not occurring after written notification has been issued. The project planner or responsible City department also has the authority to hold certificates of occupancies if compliance with a mitigation measure attached hereto is not occurring.The project planner or responsible City department has the authority to hold issuance of a business license until all mitigation measures are implemented. B. Any conditions (mitigation) that require monitoring after project completion shall be the responsibility of the City of Rancho Cucamonga Planning Division.The Division shall require the applicant to post any necessary funds (or other forms of guarantee)with the City. These funds shall be used by the City to retain consultants and/or pay for City staff time to monitor and report on the mitigation measure for the required period of time. 9. In those instances requiring long-term project monitoring, the applicant shall provide the City with a plan for monitoring the mitigation activities at the project site and reporting the monitoring results to the City. Said plan shall identify the reporter as an individual qualified to know whether the particular mitigation measure has been implemented. The monitoring/reporting plan shall conform to the City's MMP and shall be approved by the Community Development Director or City Planner prior to the issuance of building permits. MITIGATION MONITORING CHECKLIST (INITIAL STUDY PART III) Project File No.: DRC 2002-00633/SUBTPM15923 Applicant: Fountain Glen Properties LLC Initial Study Prepared by: Debra Meier Date: September 27, 2002 Mitigation Measures No. Responsible Monitoring Timing of of Verified Sanctions for Implementing Action for Monitoring Frequency Verification Verification Date/Initials Non-Compliance gg _ ' Water Prior to issuance of grading permits, the applicant shall prepare a CE/BO C Approval of SWPPP A/D 2/4 SW PPP that Identifies BMPs to be implemented during the period the site is under construction. BMPs shall be identified on the grading plans for review and approval by the City Engineer. Air Ouality '= t. . The site shall be treated with water or other soil stabilizing agent CP C Review of Plans A/C 4 (approved by SCAQMD and RWQCB)daily to reduce PM,o emissions, in accordance with SCAQMD Rule 403. Streets shall be swept according to a schedule established by the City CP C Review of Plans A/C 4 to reduce PM,,emissions associated with vehicle tracking of soil off- site.Timing may vary depending upon time of year of construction. Grading and clearing operations shall be suspended when wind CP C Review of Plans A/C 4 speeds exceed 25 mph to minimize PM10 emissions from the site during such episodes. Chemical soil stabilizers(approved by SCAQMD and RWQCB)shall CP B Review of Plans A/C 4 be applied to all inactive construction areas that remain inactive for 96 hours or more to reduce PM,,emisslons. The construction contractor shall select the construction equipment used on-site based on low emission factors and high-energy efficiency. CP C Review of Plans A/C 2/4 The construction contractor shall ensure the construction grading plans include a statement that all construction equipment will be tuned and maintained in accordance with the manufacturer's specifications. The construction contractor shall utilize electric or clean alternative fuel CP B Review of Plans A/C 2 powered equipment where feasible. The construction contractor shall ensure that construction-grading CP B Review of Plans A/C 2 plans include a statement that work crews will shut off equipment when not in use. DRC2002-00633 September 27, 2002 Key to Checklist Abbreviations ResponsiblePer'son` ' '-Monitoring�Frequenoy '' '.�'Method.ot.Veriflcatlon '`.: 3apoUona [' CDD-Community Development Director A-With Each New Development A-On-site Inspection 1 -Withhold Recordation of Final Map CP-City Planner or designee B-Prior To Construction B-Other Agency Permit/Approval 2-Withhold Grading or Building Permit CE-City Engineer or designee C-Throughout Construction C-Plan Check 3-Withhold Certificate of Occupancy BO-Building Official or designee D-On Completion D-Separate Submittal(Reports/Studies/Plans) 4-Stop Work Order PO-Police Captain or designee E-Operating 5-Retain Deposit or Bonds FC-Fire Chief or designee 6-Revoke CUP COMMUNITY DEVELOPMENT DEPARTMENT STANDARD CONDITIONS PROJECT#: SUBTPM15923 SUBJECT: APPLICANT: FOUNTAIN GLEN PROPERTIES LOCATION: SOUTHWEST CORNER CHURCH STREET AND MAYTEN AVENUE ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT. APPLICANT SHALL CONTACT THE PLANNING DIVISION, (909) 477-2750, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: A. General Requirements Completion Date 1. The applicant shall agree to defend at his sole expense any action brought against the City, its agents, officers, or employees, because of the issuance of such approval, or in the alternative, to relinquish such approval. The applicant shall reimburse the City, its agents, officers, or employees, for any Court costs and attorney's fees which the City, its agents, officers, or employees may be required by a court to pay as a result of such action. The City may, at its sole discretion, participate at its own expense in the defense of any such action but such participation shall not relieve applicant of his obligations under this condition. 2. Copies of the signed Planning Commission Resolution of Approval No. 02-98, Standard —j--j— Conditions, and all environmental mitigations shall be included on the plans (full size). The sheet(s) are for information only to all parties involved in the construction/grading activities and are not required to be wet sealed/stamped by a licensed Engineer/Architect. B. Time Limits 1. This tentative tract map or tentative parcel map shall expire, unless extended by the Planning Commission, unless a complete final map is filed with the City Engineer within 3 years from the date of the approval. C. Site Development 1. The site shall be developed and maintained in accordance with the approved plans which _/_/_ include site plans, architectural elevations, exterior materials and colors, landscaping, sign program, and grading on file in the Planning Division, the conditions contained herein, Development Code regulations, the General Plan, and the Terra Vista Community Plan. SC-08-02 1 Project No.SUBTPM15923 completion Date 2. Prior to any use of the project site or business activity being commenced thereon, all Conditions of Approval shall be completed to the satisfaction of the City Planner. 3. Occupancy of the facilities shall not commence until such time as all Uniform Building Code and State Fire Marshal regulations have been complied with. Prior to occupancy, plans shall be submitted to the Rancho Cucamonga Fire Protection District and the Building and Safety Division to show compliance. The buildings shall be inspected for compliance prior to occupancy. 4. Revised site plans and building elevations incorporating all Conditions of Approval shall be submitted for City Planner review and approval prior to the issuance of building permits. 5. All site, grading, landscape, irrigation, and street improvement plans shall be coordinated for consistency prior to issuance of any permits (such as grading, tree removal, encroachment, building, etc.) or prior to final map approval in the case of a custom lot subdivision, or approved use has commenced, whichever comes first. 6. Approval of this request shall not waive compliance with all sections of the Development Code, all other applicable City Ordinances, and applicable Community or Specific Plans in effect at the time of building permit issuance. 7. The Covenants, Conditions, and Restrictions (CC&Rsj and Articles of Incorporation of the Homeowners' Association are subject to the approval of the Planning and Engineering Divisions and the City Attorney. They shall be recorded concurrently with the Final Map or prior to the issuance of building permits, whichever occurs first. A recorded copy shall be provided to the City Engineer. The Homeowners' Association shall submit to the Planning Division a list of the name and address of their officers on or before January 1 of each and every year and whenever said information changes. 8. All parkways, open areas, and landscaping shall be permanently maintained by the property owner, homeowners' association, or other means acceptable to the City. Proof of this landscape maintenance shall be submitted for City Planner and City Engineer review and approved prior to the issuance of building permits. 9. The developer shall submit a construction access plan and schedule for the development of all lots for City Planner and City Engineer approval; including, but not limited to, public notice requirements, special street posting, phone listing for community concerns, hours of construction activity, dust control measures, and security fencing. D. Parking and Vehicular Access (indicate details on building plans) 1. The Covenants, Conditions and Restrictions shall restrict the storage of recreational vehicles on this site unless they are the principal source of transportation for the owner and prohibit parking on interior circulation aisles other than in designated visitor parking areas. E. Environmental 1. Mitigation measures are required for the project. The applicant is responsible for the cost of implementing said measures, including monitoring and reporting. Applicant shall be required to post cash, letter of credit, or other forms of guarantee acceptable to the City Planner in the amount of $719.00 prior to the issuance of building permits, guaranteeing satisfactory performance and completion of all mitigation measures. These funds may be used by the City to retain consultants and/or pay for City staff time to monitor and report on the mitigation measures. Failure to complete all actions required by the approved environmental documents shall be considered grounds for forfeit. SC-08-02 2 Project No.SUBTPM15923 Completion Date APPLICANT SHALL CONTACT THE ENGINEERING DIVISION, (909) 477-2740, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: F. Dedication and Vehicular Access 1. Dedication shall be made of the following rights-of-way on the perimeter streets (measured from street centerline): 44 total feet on Mayten Avenue 2. Corner property line cutoffs shall be dedicated per City Standards. —I�- 3. Reciprocal access easements shall be provided ensuring access to all parcels by CC&Rs or by deeds and shall be recorded concurrently with the map or prior to the issuance of building permits, where no map is involved between Parcel 1 Parcel Map 11341 and Parcel 1 Parcel Map 15923. G. Street Improvements 1. Improvement Plans and Construction: a. Street improvement plans, including street trees, street lights, and intersection safety lights on future signal poles, and traffic signal plans shall be prepared by a registered Civil Engineer and shall be submitted to and approved by the City Engineer. Security shall be posted and an agreement executed to the satisfaction of the City Engineer and the City Attorney guaranteeing completion of the public and/or private street improvements, prior to final map approval or the issuance of building permits, whichever occurs first. b. Prior to any work being performed in public right-of-way, fees shall be paid and a construction permit shall be obtained from the City Engineer's Office in addition to any other permits required. C. Pavement striping, marking, traffic signing, street name signing, traffic signal conduit, and interconnect conduit shall be installed to the satisfaction of the City Engineer. d. Handicapped access ramps shall be installed on all corners of intersections per City Standards or as directed by the City Engineer. e. Existing City roads requiring construction shall remain open to traffic at all times with adequate detours during construction. Street or lane closure permits are required. A cash deposit shall be provided to cover the cost of grading and paving, which shall be refunded upon completion of the construction to the satisfaction of the City Engineer. f. Concentrated drainage flows shall not cross sidewalks. Under sidewalk drains shall be installed to City Standards, except for single family residential lots. 2. Street trees, a minimum of 15-gallon size or larger, shall be installed per City Standards in accordance with the City's street tree program. SC-08-02 3 Project No.SUBTPM15923 Completion Date 3. Install street trees per City street tree design guidelines and standards as follows. The completed legend and construction notes shall appear on the title page of the street improvement plans. Where public landscape plans are required, tree installation in those areas shall be per the public landscape improvement plans. The City Engineer reserves the right to adjust tree species based upon field conditions and other variables. For additional information, contact Laura Bonaccorsi at extension 4023. Min, Street Name Botanical Name Common Name Grow Spacing Size' city. Space Magnolia 30-ft. fill Church Street Grandiflora NCN 8-ft. oc 15-gal in "Samuel Sommer" NCN 20-ft. fill Magnolia Gradiflora 5-ft. oc 15-gal in "St. Ma 25-ft fill Ma en Avenue Eriobotria Deflexa Bronze Loqua 3-ft. oc 15-gal in 'TREES SHALL BE 15-GALLON SIZE UNLESS OTHERWISE APPROVED. Construction Notes for Street Trees: 1) All street trees are to be planted in accordance with City standard plans. 2) Prior to the commencement of any planting, an agronomic soils report shall be furnished to the City inspector. Any unusual toxicities or nutrient deficiencies may require backfill soil amendments, as determined by the City inspector. 3) All street trees are subject to inspection and acceptance by the Engineering Division. 4) Street trees are to be planted per public improvement plans only. 4. Intersection line of sight designs shall be reviewed by the City Engineer for conformance with adopted policy. On collector or larger streets, lines of sight shall be plotted for all project intersections, including driveways. Local residential street intersections and commercial or industrial driveways may have lines of sight plotted as required. 5. A permit shall be obtained from Caltrans for any work within the following right of-way: _/_J_ Mayten Avenue at Foothill Boulevard, Foothill Boulevard. H. Public Maintenance Areas 1. A signed consent and waiver form to join and/or form the appropriate Landscape and Lighting Districts shall be filed with the City Engineer prior to final map approval or issuance of building permits whichever occurs first. Formation costs shall be borne by the developer. I. Drainage and Flood Control 1. A final drainage study shall be submitted to and approved by the City Engineer prior to final map approval or the issuance of building permits, whichever occurs first. All drainage facilities shall be installed as required by the City Engineer. SC-08-02 4 Project No.SUBTPM15923 completion Date J. Improvement Completion 1. If the required public improvements are not completed prior to approval of the final parcel map, an improvement certificate shall be placed upon the final parcel map, stating that they will be completed upon development for: Parcel 1 shall improve Church Street and Mayten Avenue to Foothill Boulevard including traffic signal. Parcel 2 shall improve Milliken Avenue Foothill Boulevard, and Mayten Avenue to Church Street including Foothill Boulevard and Mayten Avenue traffic signal. K. Utilities 1. Provide separate utility services to each parcel including sanitary sewerage system, water, gas, electric power, telephone, and cable TV (all underground) in accordance with the Utility Standards. Easements shall be provided as required. 2. The developer shall be responsible for the relocation of existing utilities as necessary. �—J- 3. Water and sewer plans shall be designed and constructed to meet the requirements of the Cucamonga County Water District (CCWD), Rancho Cucamonga Fire Protection District, and the Environmental Health Department of the County of San Bernardino. A letter of compliance from the CCWD is required prior to final map approval or issuance of permits, whichever occurs first. Such letter must have been issued by the water district within 90 days prior to final map approval in the case of subdivision or prior to the issuance of permits in the case of all other residential projects. L. General Requirements and Approvals 1. A non-refundable deposit shall be paid to the City, covering the estimated operating costs for all new streetlights for the first six months of operation, prior to final map approval or prior to building permit issuance if no map is involved. APPLICANT SHALL CONTACT THE FIRE SAFETY DIVISION, FIRE PROTECTION PLANNING SERVICES AT, (909) 477-2770, FOR COMPLIANCE WITH THE FOLLOWING CONDITIONS: SEE ATTACHED SC-08-02 5 FIRE PROTECTION DISTRICT j 1 FIRE SAFETY DIVISION STANDARD CONDITIONS FD PLAN REVIEW#: FD-02-0732-13 PROJECT#: DRC2002-00633 and SUBTPM15923 The Fountains at TV FIRE PROTECTION 1. Automatic Fire Sprinkler Throughout SYSTEM REQUIRED: 2. Class I Standpipe System LOCATION: SWC Church and Mayten FD REVIEW BY: Steve Locati Fire Protection Planning Specialist PLANNER: Debra Meier ALL OF THE FOLLOWING CONDITIONS APPLY TO YOUR PROJECT. APPLICANT SHALL CONTACT THE FIRE SAFETY DIVISION, (909) 477-2770, EXT. 3009, TO VERIFY COMPLIANCE WITH THE FOLLOWING CONDITIONS: Completion Date PLEASE CONTACT THE FIRE SAFETY DIVISION IMMEDIATELY REGARDING ITEMS IN SECTIONS "A" THROUGH "E" A. Outstanding Fire District Issues 1. The Fire District has previously provided the applicant with comments and technical requirements for this project. It the applicant has any questions regarding these comments or requirements they shall contact the Fire Safety Division.These conditions do not represent all technical requirements for issuance of construction or installation permits for this project. All comments, corrections, and conditions established by the Fire Safety Division shall be included in the construction of the project. It is the applicant's responsibility to contact the Fire Safety Division to resolve any questions. B. Fire District Fees 1. Incomplete— Fees PAID: This project has outstanding unpaid service fees in the amount of $ 132 that are due and payable at this time. To avoid delays in obtaining construction permits this matter must be resolved. Please remit payment by credit card or by check made payable to the"Rancho Cucamonga Fire District. The fees are due for the following development and planning review services: a. $132 Fire District Review of Tractor Parcel Maps other than Single-family Residential Tract $132-Fee Paid 11(15/02. " Plus a microfiche/laser-fiche fee of $1.00 per plan sheet for all final plans approved by the Fire Safety Division. 'Note: Separate plan check fees will be assessed by the Building and Safety/Fire Construction Services Unit for review of fire protection system plans and/or any consultant reviews upon submittal of plans. C. Community Facilities Districts Annexation 1. There are no Fire District annexation issues for this project. D. Available Water Supply 1. There are no Fire District water supply or fire flow issues for this project based on one of the following: a. The required verification of available water supply has been received. The Rancho Cucamonga Fire Protection District Water Availability for Fire Protection Form has been completed by the Water District and submitted to the Fire Safety Division; or b. The project does not require proof of available water supply or additional fire flow. E. Fire Access Issues 1. There are no outstanding "incompleteness"items related to FD access for this project. For outstanding technical issues see Section "GR-4"below. GENERAL REQUIREMENTS — Informational, Procedural, Technical, or Operational and Must be Included, Corrected or Completed As Noted GR-1 General Requirements for Public and Private Water Supply 1. Minimum Fire Flow: The required fire flow for this project is 4000 gallons per minute at a minimum residual pressure of 20 pounds per square inch. This requirement is made in accordance with Fire Code Appendix III-A, as amended. CCWD reports required flow available. GR-2 Private (On-Site)Water and/or Fire Sprinkler Underground Plans for Fire Protection 1. Exceeds Allowable Distance:When any portion of a facility or building is located more than 150-feet from a fire hydrant located on a public street, as measured by an approved route around the exterior of the facility or building, on-site fire hydrants and mains capable of supplying the required fire flow shall be provided. The distance is measured as vehicular path of travel on access roadways, not line of sight. Contact the Fire Safety Division (909) 477-2770 GR-3 Automatic Fire Sprinkler Systems-Technical Comments 1. Required Installations: Rancho Cucamonga Fire District Ordinance 15 or other adopted code or standard, requires an approved automatic fire sprinkler system to be installed in any of the following: a. Multi-family residential structures Contact the Fire Safety Division (909)477-2770 GR-4 Fire District Site Access-Technical Comments 1. Access Roadways Defined: Fire District access roadways include public roads, streets, and highways, as well as private roads, streets, drive aisles and designated fire lanes. 2. Location of Access: All portions of the structure or facility or any portion of the exterior wall of the first story shall be located within 150-feet of Fire District vehicle access, measured by an unobstructed approved route around the exterior of the building. Landscaped areas, unpaved changes in elevation, gates, and fences are an obstruction. 3. Access Walkways: Approved access walkways shall be provided from the fire apparatus access road to all required exterior building openings. 4. Gates Standards: All gates shall be installed in accordance with Fire District Standards. The following general design requirements apply: a. The gate shall be motorized and slide open horizontally or swing inward. b. All gates must fully open with one second for each one foot of required width, e.g., 20-ft./20 sec. c. When fully open the minimum width shall be 20-feet. d. Gates on access roads designated "Emergency Services Use Only" may be manually opening. e. Gates on Commercial/Industrial facilities may be manually operated. f. After project approval the applicant shall contact the Fire Safety Division for complete standard. Contact the Fire Safety Division 909 477-2770 5. Restricted Residential Access: Gated or access for all residential development shall comply with the following: a. All automatic gates shall be provided with a Fire District approved,compatible traffic pre-emption device. Approved devices are available from Opticom (3M), Fire Strobe 2000(Access Products Inc.), and Tomar Electronics. Devices shall be installed in accordance with the manufacturer's instructions and specifications. b. A Knox Rapid Entry System Key Box is required to be installed adjacent to each gate in a Fire District approved location.The box shall be mounted where it is clearly visible and access is unobstructed. c. Vehicle access gates shall be provided with an approved Fire District Knox Key Switch. d. The key switch shall be located immediately adjacent to the Knox Box for use in the event that the traffic pre-emption device fails to operate. e. The gate shall remain in the open position for not less than 20-minutes and shall automatically reset. Contact Building and Safety/Fire Construction Services (909)477-2713 for inspection. 6. Vegetation: Trees and shrubs planted in any median shall be kept trimmed to a minimum of 14-feet, 6-inches from the ground up, so as not to impede fire vehicles. Contact the Fire Safety Division (909) 477-2770 7. Fire Lane Identification: All required fire lanes shall be identified by red curbing and signage. A drawing of the proposed signage that meets the minimum Fire District standards shall be submitted to and approved. Contact the Rancho Cucamonga Fire Protection District at (909) 477-2770 for a copy of the FD Fire Lanes standard. GR-10 Hazard Control Permits-Technical Comments This project may require special or hazard control permits. The Certificate of Occupancy cannot be issued until all permit requirements are satisfied. Refer to Preliminary Review or Technical Review comments for specific information. GR-11 Hazardous Materials'—Compliance with Disclosure and Reporting Regulations The San Bernardino County Fire Department shall review your Business Emergency/Contingency Plan for compliance with minimum standards. Contact the San Bernardino County Fire, Hazardous Materials Division at (909) 387-8400 for forms and assistance. The County Fire Department is the Cal/EPA Certified Unified Program Agency (CUPA) for the City of Rancho Cucamonga. 1. Certificate of Occupancy Restrictions: If the facility is a NEW business, a Certificate of Occupancy issued by Building and Safety will not be finalized until the San Bernardino County Fire Department reviews your Business Emergency/Contingency Plan. California Government Code, Section 65850.2 prohibits the City from issuing a final Certificate of Occupancy unless the applicant has met or is meeting specific hazardous material disclosure requirements. A Risk Management Program (RMP) may also be required if regulated substances are to be used or stored at the new facility. Contact County Fire, Hazardous Materials Division at(909) 387-8400 for forms and assistance. 2. Fire District Code Adoption: The Fire Code adopted by the Fire District has a provision requiring collection of information regarding hazardous materials at facilities for purposes of Fire Code implementation and emergency response. GR-12 Plan Submittal Required Notice Required plans shall be submitted and approved prior to construction in accordance with 1997/98 Building, Fire, Mechanical, and Plumbing Codes; 1999 Electrical Code; Health and Safety Code; Public Resources Code; and RCFPD Ordinances FD15 and FD32, Guidelines and Standards. NOTE: In addition to the fees due at this time please note that separate plan check fees for tenant improvements,fire protection systems and/or any consultant reviews will be assessed at time of submittal of plans. GR-14 Alternate Materials and Methods The Fire Safety Division will review requests for alternate materials and methods within the scope of our authority. The request must be submitted on the Fire District"Application for Alternate Method"form along with supporting documents. Contact the Fire Safety Division at (909)477-2770 for assistance. PRIOR TO ISSUANCE OF GRADING PERMIT- For Each Development Phase 1. Fire District Site Access Plan: Prior to the issuance of any grading permit the applicant shall submit a Fire District Site Access Plan to the Fire District for review and approval. The following, minimum information and 'detail shall be included a on a scaled site plan: a. All roadways shall be clearly indicated. Including roadway width, vertical clearances, cul-de-sac width, turn radii, curb cuts, angle of departure, grades, etc. b. For private roadways or drive aisles less than 40-feet or less in width where parking may be permitted, identify the location of proposed fire lanes. c. Include a note stating all required fire lanes shall be identified by red curbing and signage. d. Include detail(s)to identify which of the methods set forth in the Fire District"Fire Lane"standard will be used to mark the fire lane. A copy of the Fire District"Fire Lane" Standard can be obtained by calling (909) 477-2770. e. Roadway with a width of more than 40-feet parking is permitted on both sides. f. Roadway with a width of 32-feet or more parking is permitted on one side only. g. The angle of departure and approach shall not exceed 9 degrees or 20 percent. h. The grade of any fire district access roadway shall not exceed 12 percent. i. If water plans have been approved, include,fire hydrant and fire department connection locations. Contact the Fire Safety Division at 909 477-2770 for assistance. 2. All Gates: Prior to the issuance of any grading permits,the applicant shall submit and obtain the Fire District's approval of the construction of any gate across required Fire District access roadways/driveways. A Fire District permit is required for installation of any gate or other device that will impede Fire District response. PRIOR TO (PARCEL) MAP RECORDATION- For Each Development Phase 1. Reciprocal Access Agreement: The plans as submitted indicate that a required point of Fire District access: a. Requires passage on property not under the control of the applicant; or b. Does not access a public way; or c. Crosses a property line Please provide a permanent access agreement granting irrevocable use of the adjacent property for use by the Fire District to gain access to the subject property. The agreement shall include a statement that no obstruction, gate, fence, building, or other structure shall be placed within the dedicated access. The recorded agreement shall include a copy of the site plan required below. The agreement shall be recorded with the County of San Bernardino, Recorders Office. The agreement shall be approved by the Fire Safety Division prior to recordation. To assist the Fire Safety Division in reviewing the agreement the following shall be included in the submittal: a. Title Report. A current title report, policy of title insurance, or other equivalent documentation proving ownership of all property included in the agreement. b. Legal Description. A legal description of all property subject to the agreement. c. Assessor's Parcel Numbers. The assessor's parcel numbers of each parcel subject to the agreement. d. Site Plan: The access roadway shall comply with the requirements of Private Roadways and Fire Lanes listed above. A scaled site plan showing the path of the Fire District access, the width, turn radii, load-bearing capacity of roadway surface, etc. shall be provided. Contact the Fire Safety Division 909 477-2770 PRIOR TO ISSUANCE OF BUILDING PERMITS- Complete the following: 1. Private/On-site Fire Hydrants: Prior to the issuance of any building permit, the applicant shall submit construction plans, specifications, flow test data and calculations for the private water main system for review and approval by the Fire District. Plans and installation shall comply with Fire District standards. Contac the Fire Safety Division for a copy of"Fire District Notes for Underground and Water Plans." Contact the Fire Safety Division (909)477-2770 2. Public Fire Hydrants: Prior to issuance of any building permit, the applicant shall submit a plan showing the locations of all new public fire hydrants for the review and approval by the Fire District and the Water District. On the plan show all existing fire hydrants within a 600- foot radius of the project. Contact the Fire Safety Division (909) 477-2770 3. Hazardous Fire Area Construction: The project is located within the designated Hazardous Fire Area. All buildings and structures shall be constructed in accordance with the provisions of County Fire Safety Review Area (One or Two) [FR-1/FR-21 standards. In the Hazardous Fire Area the applicant shall provide a modified one-hour fire-resistive wall for the following exterior wall(s): a.) North b.)South c.)East d.)West sides Contact the Fire Safety Division 909 477-2770